HomeMy WebLinkAboutChevron 1125 Coffee Rd. FMCATG IMPACT VALVE LEAK DETECTOR SPILL BUCKET TEST 11000 N. MoPac Expressway, Suite 500 Austin, Texas 78759 Phone: (512) 451-6334 Fax: (512) 459-1459 Date Printed and Mailed: 10/2/2013 BAKERSFIELD FIRE DEPARTMENT OFFICE OF ENVIRONMENTAL SERVICES INSPECTOR CRAIG PERKINS 1501 TRUXTUN AVE. BAKERSFIELD, CA 93301 Test Date: 9/18/2013 Order Number: 3414454 Dear Regulator, Enclosed are the results of recent testing performed at the following facility: CHEVRON 203576 1125 COFFEE RD. BAKERSFIELD, CA 93308 Testing performed: Sincerely, Dawn Kohlmeyer Manager, Field Reporting LDT 5000 Field Test Apparatus Line Leak Detector Test Page 1 of 1 Work Order:3414454 Date:9/18/2013 Site Name / ID:CHEVRON 203576 / 203576 Address:1125 COFFEE RD. City:BAKERSFIELD State:CA Zip:93308 Tank ID Product Product Line Tested From Existing/New Mechanical/Electronic Manufacturer/Model Serial No. Pump Operating Pressure (psi) Calibrated Leak (ml/min) Calibrated Leak (gph) Holding PSI *N/A for Electronic LD's Resiliency (ml) *N/A for Electronic LD's Metering PSI *N/A for Electronic LD's Opening Time (sec) *N/A for Electronic LD's Test Results T1 SUPREME SUPREME 1 3 Existing Electronic Veeder Root PLLD 011505 32.00 189.0 3.00 Fail T2 PLUS PLUS 1 3 Existing Electronic Veeder Root PLLD 013652 29.00 189.0 3.00 Pass T3 REGULAR REGULAR 1 3 Existing Electronic Veeder Root PLLD 013649 31.00 189.0 3.00 Pass Technician Comments: Technician Name:Edwin Pineda Certification #:2344 Technician Signature:Expire Date:4/5/2015 Environmental Compliance for Petroleum Systems © 2013 Tanknology Inc., Austin, TX.    All rights reserved.    tanknology.com Impact Valve Inspection Impact Valve Operational Inspection Work Order:3414454 Date:9/18/2013 Site Name/ID:CHEVRON 203576 Address:1125 COFFEE RD. City:BAKERSFIELD State:CA Zip:93308 Dispenser Number Grade Secure Mount? Valve Lock?Pass/ Fail Comments 1/2 87 Pass Fail Not Tested 1/2 89 Pass Fail Not Tested 1/2 91 Pass Fail Not Tested 3/4 87 Pass Fail Not Tested 3/4 89 Pass Fail Not Tested 3/4 91 Pass Fail Not Tested 5/6 87 Pass Fail Not Tested 5/6 89 Pass Fail Not Tested 5/6 91 Pass Fail Not Tested 7/8 87 Pass Fail Not Tested 7/8 89 Pass Fail Not Tested 7/8 91 Pass Fail Not Tested 9/10 87 Pass Fail Not Tested 9/10 89 Pass Fail Not Tested 9/10 91 Pass Fail Not Tested 11/12 87 Pass Fail Not Tested 11/12 89 Pass Fail Not Tested 11/12 91 Pass Fail Not Tested Technician Comments: Technician Name:Edwin Pineda Signature: Environmental Compliance for Petroleum Systems ©2013 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com Appendix VI (Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at http://www.swrcb.ca.gov.) MONITORING SYSTEM CERTIFICATION For Use By All Jurisdictions Within the State of California Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. A. General Information Facility Name:CHEVRON 203576 Bldg. No.: Site Address:1125 COFFEE RD.City:BAKERSFIELD Zip:93308 Facility Contact Person:KATHY Contact Phone No.:661-588-9066 Make/Model of Monitoring System:Veeder Root TLS 350 Date of Testing/Servicing:9/18/2013 B. Inventory of Equipment Tested/Certified Check the appropriate boxes to indicate specific equipment inspected/serviced: Tank ID:T1 SUPREME - SUPREME In-Tank Gauging Probe.Model:MAG PROBE Annular Space or Vault Sensor.Model:VR-409 Piping Sump / Trench Sensor(s).Model:VR-208 Fill Sump Sensor(s).Model: Mechanical Line Leak Detector.Model: Electronic Line Leak Detector.Model:Veeder Root PLLD Tank Overfill / High-Level Sensor.Model:PROBE/EXTERNAL Other (specify equipment type and model in Section E on Page 2). Tank ID:T2 PLUS - PLUS In-Tank Gauging Probe.Model:MAG PROBE Annular Space or Vault Sensor.Model:VR-409 Piping Sump / Trench Sensor(s).Model:VR-208 Fill Sump Sensor(s).Model: Mechanical Line Leak Detector.Model: Electronic Line Leak Detector.Model:Veeder Root PLLD Tank Overfill / High-Level Sensor.Model:PROBE/EXTERNAL Other (specify equipment type and model in Section E on Page 2). Tank ID:T3 REGULAR - REGULAR In-Tank Gauging Probe.Model:MAG PROBE Annular Space or Vault Sensor.Model:VR-409 Piping Sump / Trench Sensor(s).Model:VR-208 Fill Sump Sensor(s).Model: Mechanical Line Leak Detector.Model: Electronic Line Leak Detector.Model:Veeder Root PLLD Tank Overfill / High-Level Sensor.Model:PROBE/EXTERNAL Other (specify equipment type and model in Section E on Page 2). Tank ID: In-Tank Gauging Probe.Model: Annular Space or Vault Sensor.Model: Piping Sump / Trench Sensor(s).Model: Fill Sump Sensor(s).Model: Mechanical Line Leak Detector.Model: Electronic Line Leak Detector.Model: Tank Overfill / High-Level Sensor.Model: Other (specify equipment type and model in Section E on Page 2). Dispenser ID:1/2 Dispenser Containment Sensor(s).Model:BE -406 Shear Valve(s). Dispenser Containment Float(s) and Chain(s). Dispenser ID:3/4 Dispenser Containment Sensor(s).Model:BE-406 Shear Valve(s). Dispenser Containment Float(s) and Chain(s). Dispenser ID:5/6 Dispenser Containment Sensor(s).Model:BE-406 Shear Valve(s). Dispenser Containment Float(s) and Chain(s). Dispenser ID:7/8 Dispenser Containment Sensor(s).Model:BE-406 Shear Valve(s). Dispenser Containment Float(s) and Chain(s). Dispenser ID:9/10 Dispenser Containment Sensor(s).Model:BE-406 Shear Valve(s). Dispenser Containment Float(s) and Chain(s). Dispenser ID:11/12 Dispenser Containment Sensor(s).Model:BE-406 Shear Valve(s). Dispenser Containment Float(s) and Chain(s). *If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers’ guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a copy of the report; (check all that apply): System set- up Alarm history report Technician Name (print):Edwin Pineda Signature: Certification No.:B37453 License. No.:743160 Class 'A' Testing Company Name:Tanknology Phone No.:(800) 800-4633 Testing Company Address:11000 N. MoPac Expressway Suite 500 Date of Testing/Servicing:9/18/2013 Monitoring System Certification Page 1 of 3 12/07 D. Results of Testing/Servicing Software Version Installed:332.00 Complete the following checklist: Yes No*Is the audible alarm operational? Yes No*Is the visual alarm operational? Yes No*Were all sensors visually inspected, functionally tested, and confirmed operational? Yes No*Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere with their proper operation? Yes No* N/A If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) operational? Yes No* N/A For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate positive shut-down? (Check all that apply) Sump/Trench Sensors; Dispenser Containment Sensors. Did you confirm positive shut-down due to leaks and sensor failure/disconnection? Yes; No Yes No* N/A For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank fill point(s) and operating properly? If so, at what percent of tank capacity does the alarm trigger? 90% Yes* No Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced and list the manufacturer name and model for all replacement parts in Section E, below. Yes* No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) Product; Water. If yes, describe causes in Section E, below. Yes No*Was monitoring system set-up reviewed to ensure proper settings? Attach set up reports, if applicable Yes No*Is all monitoring equipment operational per manufacturer's specifications? * In Section E below, describe how and when these deficiencies were or will be corrected. E. Comments: 91 LEAK DETECTOR FAIL,REPLACE SIPHON JET VALVE AND PURGE ABOUT 200 GALLONS OF FUEL. Monitoring System Certification Page 2 of 3 12/07 F. In-Tank Gauging / SIR Equipment: Check this box if tank gauging is used only for inventory control. Check this box if no tank gauging or SIR equipment is installed. This section must be completed if in-tank gauging equipment is used to perform leak detection monitoring. Complete the following checklist: Yes No*Has all input wiring been inspected for proper entry and termination, including testing for ground faults? Yes No*Were all tank gauging probes visually inspected for damage and residue buildup? Yes No*Was accuracy of system product level readings tested? Yes No*Was accuracy of system water level readings tested? Yes No*Were all probes reinstalled properly? Yes No*Were all items on the equipment manufacturer's maintenance checklist completed? * In the Section H, below, describe how and when these deficiencies were or will be corrected. G. Line Leak Detectors (LLD): Check this box if LLDs are not installed. Complete the following checklist: Yes No* N/A For equipment start-up or annual equipment certification, was a leak simulated to verify LLD performance? (Check all that apply) Simulated leak rate: 3 g.p.h.; 0.1 g.p.h; 0.2 g.p.h. Yes No*Were all LLDs confirmed operational and accurate within regulatory requirements? Yes No*Was the testing apparatus properly calibrated? Yes No* N/A For mechanical LLDs, does the LLD restrict product flow if it detects a leak? Yes No* N/A For electronic LLDs, does the turbine automatically shut off if the LLD detects a leak? Yes No* N/A For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? Yes No* N/A For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a test? Yes No* N/A For electronic LLDs, have all accessible wiring connections been visually inspected? Yes No*Were all items on the equipment manufacturer's maintenance checklist completed? * In the Section H, below, describe how and when these deficiencies were or will be corrected. H.Comments: Page 3 of 3 12/07 SWRCB, January 2002 Page 1 of 1 Secondary Containment Testing Report Form This form is intended for use by contractors performing periodic testing of UST secondary containment systems. Use the appropriate pages of this form to report results for all components tested. The completed form, written test procedures, and printouts from tests (if applicable), should be provided to the facility owner/operator for submittal to the local regulatory agency. 1. FACILITY INFORMATION Facility Name: CHEVRON 203576 Date of Testing: 9/18/2013 Facility Address: 1125 COFFEE RD. , BAKERSFIELD, CA 93308 Facility Contact: KATHY Phone: 661-588-9066 Date Local Agency Was Notified of Testing: 9/5/2013 Name of Local Agency Inspector (if present during testing): Ernie Medina 2. TESTING CONTRACTOR INFORMATION Company Name: TANKNOLOGY INC. Technician Conducting Test: Edwin Pineda Credentials: CSLB Licensed Contractor SWRCB Licensed Tank Tester License Type: A-U License Number: 743160-8026748 Manufacturer Manufacturer Training Component(s)Date Training Expires PHILTITE SPILL BUCKETS 8/8/2014 3. SUMMARY OF TEST RESULTS Component Pass Fail Not Tested Repairs Made Spill Box T1 SUPREME supreme fill X Spill Box T2 PLUS plus fill X Spill Box T3 REGULAR regular fill X Component Pass Fail Not Tested Repairs Made If hydrostatic testing was performed, describe what was done with the water after completion of tests: CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING To the best of my knowledge, the facts stated in this document are accurate and in full compliance with legal requirements Technician's Signature:Date:9/18/2013 WO: 3414454 WATER WAS PUT IN FIVE GALLON BUCKETS AND PUT IN TRUCK FOR NEXT SITE. SWRCB, January 2002 Page 1 of 1 9. SPILL/OVERFILL CONTAINMENT BOXES Facility is Not Equipped With Spill/Overfill Containment Boxes Spill/Overfill Containment Boxes are Present, but were Not Tested Test Method Developed By: Spill Bucket Manufacturer Industry Standard Professional Engineer Other (Specify): Test Method Used By: Pressure Vacuum Hydrostatic Other (Specify): Test Equipment Used:Equipment Resolution: Bucket Diameter: Bucket Depth: Wait time between applying pressure/vacuum/water and starting test Test Start Time: Initial Reading (RI): Test End Time: Final Reading (RF): Test Duration: Change in Reading (RF-RI) : Pass/Fail Threshold or Criteria: Test Result: Spill Box # Tank T1 SUPREME SUPREME - Fill 1 - Direct - Grade level 12.00 14.00 0 min 09:00:00 11.00 in. H20 10:00:00 11.00 in. H20 1 hr 0.00 in. H20 +/- 0.00 Pass Spill Box # Tank T2 PLUS PLUS - Fill 1 - Direct - Grade level 12.00 14.00 0 min 09:00:00 11.00 in. H20 10:00:00 11.00 in. H20 1 hr 0.00 in. H20 +/- 0.00 Pass Spill Box # Tank T3 REGULAR REGULAR - Fill 1 - Direct - Grade level 12.00 14.00 0 min 09:00:00 11.00 in. H20 10:00:00 11.00 in. H20 1 hr 0.00 in. H20 +/- 0.00 Pass Spill Box # min +/- Comments - (include information on repairs made prior to testing, and recommended follow-up for failed tests) WO: 3414454 Site Diagram (This site diagram is for reference only and is not drawn to scale) Work Order:3414454 Site ID / Name:203576 / CHEVRON 203576 Address:1125 COFFEE RD. City:BAKERSFIELD State:CA Zip:93308 W.O.# SC1-3414454 Cust Ref#: PO: 0015114456 I10100 SEP 18, 2013 2:11 PM C.S.I.CHEVRON 1842 1125 COFFEE RD. BAKERSFIELD,CA 93312 661-588-9066 203576 SYSTEM STATUS REPORT ALL FUNCTIONS NORMAL I50301 SEP 18, 2013 2:11 PM # 1:C.S.I.CHEVRON 1842 I50302 SEP 18, 2013 2:11 PM # 2:1125 COFFEE RD. I50303 SEP 18, 2013 2:11 PM # 3:BAKERSFIELD,CA 93312 I50304 SEP 18, 2013 2:11 PM # 4:661-588-9066 203576 I51700 SEP 18, 2013 2:12 PM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM I50F00 SEP 18, 2013 2:12 PM MON DD YYYY HH:MM:SS xM I60100 SEP 18, 2013 2:12 PM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 SUPREME ON 2 PLUS ON 3 REGULAR ON 4 OFF I60200 SEP 18, 2013 2:12 PM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 SUPREME 2 PLUS 3 REGULAR 4 I60300 SEP 18, 2013 2:12 PM TANK PRODUCT CODE TANK PRODUCT LABEL 1 SUPREME 1 2 PLUS 2 3 REGULAR 3 4 4 I60400 SEP 18, 2013 2:12 PM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 SUPREME 12022 2 PLUS 12022 3 REGULAR 12022 4 0 I60700 SEP 18, 2013 2:12 PM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 SUPREME 111.00 2 PLUS 111.00 3 REGULAR 111.00 4 0.00 I60900 SEP 18, 2013 2:12 PM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 SUPREME 0.000700 2 PLUS 0.000700 3 REGULAR 0.000700 4 0.000000 I61200 SEP 18, 2013 2:12 PM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 SUPREME NONE NONE 2 PLUS NONE NONE 3 REGULAR NONE NONE 4 NONE NONE I62100 SEP 18, 2013 2:12 PM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 SUPREME 500 2 PLUS 500 3 REGULAR 500 4 0 I62200 SEP 18, 2013 2:12 PM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 SUPREME 11464 2 PLUS 11464 3 REGULAR 11464 4 0 I62300 SEP 18, 2013 2:12 PM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 SUPREME 10861 2 PLUS 10861 3 REGULAR 10861 4 0 I62400 SEP 18, 2013 2:12 PM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 SUPREME 3.0 2 PLUS 3.0 3 REGULAR 3.0 I62800 SEP 18, 2013 2:12 PM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 SUPREME 12068 2 PLUS 12068 3 REGULAR 12068 4 0 I62900 SEP 18, 2013 2:12 PM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 SUPREME 1206 2 PLUS 1206 3 REGULAR 1206 4 0 I70300 SEP 18, 2013 2:12 PM LIQUID TYPE SENSOR LOCATION TYPE 1 SUPREME TURBINE SUMP TRI-STATE (SINGLE FLOAT) 2 SUPREME ANNULAR TRI-STATE (SINGLE FLOAT) 3 REG TURBINE SUMP TRI-STATE (SINGLE FLOAT) 4 PLUS ANNULAR TRI-STATE (SINGLE FLOAT) 5 PLUS TURBINE SUMP TRI-STATE (SINGLE FLOAT) 6 REGULAR ANNULAR TRI-STATE (SINGLE FLOAT) 7 TRI-STATE (SINGLE FLOAT) 8 TRI-STATE (SINGLE FLOAT) I78500 SEP 18, 2013 2:13 PM PRESSURE LINE LEAK TANK NUMBER LINE TANK NUMBER Q 1:SUPREME 1 Q 2:PLUS 2 Q 3:REGULAR 3 I90200 SEP 18, 2013 2:13 PM SOFTWARE REVISION LEVEL VERSION 332.00 SOFTWARE# 346332-100-A CREATED - 11.05.27.16.12 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I20600 SEP 18, 2013 2:13 PM C.S.I.CHEVRON 1842 1125 COFFEE RD. BAKERSFIELD,CA 93312 661-588-9066 203576 TANK ALARM HISTORY TANK 1 SUPREME HIGH WATER ALARM OCT 12, 2012 8:54 AM OVERFILL ALARM OCT 12, 2012 8:58 AM LOW PRODUCT ALARM OCT 12, 2012 9:04 AM SUDDEN LOSS ALARM OCT 12, 2012 8:49 AM HIGH PRODUCT ALARM OCT 12, 2012 8:58 AM INVALID FUEL LEVEL NOV 14, 2012 3:12 PM OCT 12, 2012 9:04 AM OCT 12, 2012 8:51 AM PROBE OUT OCT 12, 2012 9:05 AM HIGH WATER WARNING OCT 12, 2012 8:54 AM DELIVERY NEEDED JUN 3, 2013 1:14 PM MAR 11, 2013 4:17 PM FEB 17, 2013 4:37 PM MAX PRODUCT ALARM OCT 12, 2012 9:01 AM LOW TEMP WARNING OCT 12, 2012 9:05 AM TANK 2 PLUS HIGH WATER ALARM OCT 12, 2012 8:58 AM OVERFILL ALARM OCT 12, 2012 8:59 AM SUDDEN LOSS ALARM OCT 12, 2012 8:54 AM HIGH PRODUCT ALARM OCT 12, 2012 8:59 AM INVALID FUEL LEVEL OCT 12, 2012 8:55 AM HIGH WATER WARNING OCT 12, 2012 8:58 AM DELIVERY NEEDED MAY 31, 2013 7:07 PM APR 11, 2013 6:52 PM FEB 19, 2013 4:47 PM MAX PRODUCT ALARM OCT 12, 2012 9:02 AM LOW TEMP WARNING OCT 12, 2012 9:09 AM TANK 3 REGULAR HIGH WATER ALARM OCT 12, 2012 8:56 AM OVERFILL ALARM OCT 12, 2012 8:58 AM LOW PRODUCT ALARM OCT 5, 2012 4:37 PM OCT 5, 2012 10:57 AM SUDDEN LOSS ALARM OCT 12, 2012 8:52 AM OCT 5, 2012 4:34 PM HIGH PRODUCT ALARM OCT 12, 2012 8:58 AM INVALID FUEL LEVEL NOV 16, 2012 5:24 PM OCT 12, 2012 9:07 AM OCT 12, 2012 8:53 AM HIGH WATER WARNING OCT 12, 2012 8:56 AM DELIVERY NEEDED JUL 20, 2013 7:29 PM DEC 15, 2012 7:45 AM NOV 16, 2012 3:24 PM MAX PRODUCT ALARM OCT 12, 2012 9:01 AM TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 I30200 SEP 18, 2013 2:14 PM C.S.I.CHEVRON 1842 1125 COFFEE RD. BAKERSFIELD,CA 93312 661-588-9066 203576 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 SUPREME TURBINE SUMP SEP 18, 2013 9:21 AM SENSOR OUT ALARM SEP 18, 2013 8:56 AM FUEL ALARM OCT 12, 2012 9:22 AM SENSOR OUT ALARM 2 SUPREME ANNULAR SEP 18, 2013 9:21 AM SENSOR OUT ALARM SEP 18, 2013 9:00 AM FUEL ALARM OCT 12, 2012 9:22 AM SENSOR OUT ALARM 3 REG TURBINE SUMP SEP 18, 2013 9:21 AM SENSOR OUT ALARM SEP 18, 2013 8:55 AM FUEL ALARM SEP 11, 2013 11:13 AM FUEL ALARM 4 PLUS ANNULAR SEP 18, 2013 9:21 AM SENSOR OUT ALARM SEP 18, 2013 8:57 AM FUEL ALARM OCT 12, 2012 9:22 AM SENSOR OUT ALARM 5 PLUS TURBINE SUMP SEP 18, 2013 9:21 AM SENSOR OUT ALARM SEP 18, 2013 8:51 AM FUEL ALARM OCT 12, 2012 9:22 AM SENSOR OUT ALARM 6 REGULAR ANNULAR SEP 18, 2013 9:21 AM SENSOR OUT ALARM SEP 18, 2013 8:59 AM FUEL ALARM OCT 12, 2012 9:22 AM SENSOR OUT ALARM I38200 SEP 18, 2013 2:15 PM C.S.I.CHEVRON 1842 1125 COFFEE RD. BAKERSFIELD,CA 93312 661-588-9066 203576 PRESSURE LINE LEAK ALARM HISTORY REPORT Q 1:SUPREME SEP 18, 2013 9:21 AM PLLD SHUTDOWN ALARM SEP 18, 2013 9:00 AM PLLD SHUTDOWN ALARM SEP 18, 2013 8:56 AM PLLD SHUTDOWN ALARM SEP 12, 2013 3:59 PM PLLD SHUTDOWN ALARM SEP 12, 2013 3:59 PM GROSS LINE FAIL AUG 17, 2013 8:04 AM PLLD SHUTDOWN ALARM JUN 21, 2013 8:03 AM PLLD SHUTDOWN ALARM NOV 10, 2012 8:04 AM PLLD SHUTDOWN ALARM OCT 12, 2012 9:53 AM PLLD SHUTDOWN ALARM OCT 12, 2012 9:53 AM GROSS LINE FAIL Q 2:PLUS SEP 18, 2013 10:24 AM PLLD SHUTDOWN ALARM SEP 18, 2013 10:24 AM GROSS LINE FAIL SEP 18, 2013 9:21 AM PLLD SHUTDOWN ALARM SEP 18, 2013 8:57 AM PLLD SHUTDOWN ALARM SEP 18, 2013 8:51 AM PLLD SHUTDOWN ALARM AUG 17, 2013 8:04 AM PLLD SHUTDOWN ALARM JUN 21, 2013 8:03 AM PLLD SHUTDOWN ALARM NOV 10, 2012 8:04 AM PLLD SHUTDOWN ALARM OCT 12, 2012 9:46 AM PLLD SHUTDOWN ALARM OCT 12, 2012 9:46 AM GROSS LINE FAIL Q 3:REGULAR SEP 18, 2013 10:30 AM PLLD SHUTDOWN ALARM SEP 18, 2013 10:30 AM GROSS LINE FAIL SEP 18, 2013 9:21 AM PLLD SHUTDOWN ALARM SEP 18, 2013 8:59 AM PLLD SHUTDOWN ALARM SEP 18, 2013 8:55 AM PLLD SHUTDOWN ALARM SEP 11, 2013 11:13 AM PLLD SHUTDOWN ALARM AUG 17, 2013 8:04 AM PLLD SHUTDOWN ALARM JUN 21, 2013 8:03 AM PLLD SHUTDOWN ALARM NOV 16, 2012 5:56 PM FUEL OUT NOV 10, 2012 8:04 AM PLLD SHUTDOWN ALARM I10100 SEP 18, 2013 2:16 PM C.S.I.CHEVRON 1842 1125 COFFEE RD. BAKERSFIELD,CA 93312 661-588-9066 203576 SYSTEM STATUS REPORT ALL FUNCTIONS NORMAL