HomeMy WebLinkAboutFMC 2013MONITORING SYSTEM CERTIFICATION For Use By All Jurisdictions Wit/tin the State of Cal[fomia Autltorizv Cited: Chapter 6. 7, Health and Sc!fety Code; Chapter 16, Division 3, Title 23, California Code q{Regulations This form must be used to document testing and servicing of monitoring equipment. A separate eenification or report must be prepared for each monitoring system control pan~l by the technician who perfonns the work. A copy of this form must be provided to the tank system owner/operator. The owner/operator must submit a copy of this fonn to the local agency regulating tSr ~ystems within 30 days of test date. A. General Information Facility Name: Ramco Express Bldg. No.: ----- Site Address: 2222 F Street City: Bakersfield Zip: .;;...93,_3_0_1 __ _ Facility Contact Person: Rami Contact Phone No.: (661) 324-1758 Make/Model of Monitoring System: Veeder-Root TLS-350 Date ofTesting/Servicing: 12/19/2013 B. Inventory of Equipment Tested/Certified '-'11'-'-" '-tl\.. fiJI loll V IIHI"-VV-'"-" IV ltiUt'-UI"' .;J "'-'-'"'-'-"'UI '"""''" , .. ,,. ''-'-''-''-"'''-' .. , ....... u. Tank 10: 10,000 gal. Regualr Tank 10: 10,000 gal. Plus 181 In-Tank Gauging Probe. Model: 847390-107 1811n· rank Gauging Prolx:. Model: 847390-107 181 Annular Space or Vault Sensor. Model: 794390-409 181 Annular Space or Vauh Scrl'><lr. Model: 794390-409 181 Piping 'iump I n.>r!Ch Sensor(s). Model: 794380-208 181 Pipmg Sump/Trench Scn...or(s). Model: 794380-208 D Fill Sump ScrMr(s). Model: 0 Fill Sump Scnsor(s). Model: 0 Mechanic:1ll.inc l.eak Detector. Model: 0 Ml.-chanical Line Lc<tk Dcli .. 'Ctor. Model: 181 Electronic l..inc l.cak Detector. Model: PLLD 181 I'IL-ctronic Line Leak Detector. Model: PLLD 181 Tank Overfill/It igh-Level Scrt~r. Model: OPW-61-SO 181 Tank Overfill/ H igh-t..evcl Scm.or. Model: OPW-61-SO 0 Otherhpccify equipment type and model in Section con Page 2). 0 Other (specify equipml.'llttype and model in Section I' on Page 2). Tank 10: 10,000 gal. Sueer Tank 10: 1811n-Tnnk Gaugmg Probe. Model: 847390-107 0 In-I ank Gauging Prolx:. \olodcl: 181 Annulnr Space or Vault Sensor. Model: 794390-409 0 Annular Space or Vault Sc~t,or. Model: 181 Piping Sump I Trench Scnsor(s). Model: 794380-208 0 Piping Sump/Trench Scnsor(s). Model: 0 Fill Sump Scnwr(s). Model: D Fill Sump Scnsor(s). Model: 0 Mechanical I inc l.cak Detector. Model: D Mechanical Line Leak Dctl.'Ctor. Model: 181 Electronic I inc I cak Detector. Model: PLLD 0 Hectmnic Line Leak Dcwctor. Model: 181lank Overfill lligh-l.cvel Sen..or \olodcl: OPW-61-SO 0 I ank 0\crfill/ High-t e\cl Scn .... or. Model: D Other ('(l(.'Ctfy equipment type and model in Section Eon Page 2). 0 Other (specifY equipment type and model in Section I on Page 2). Dispenser 10: 1-2 Dispenser I D: 3 -4 D Dispenser Containment Sensor(s). Model: D Dispenser Containment Scnsor(s). Model: 181 Shear Valvl.'{s). 181 Shear Valvc(s). 181 Dispcn.<.,cr ( 'ontainment Float(s) and C'hain(s). 181 Dbpenscr Containment 1-loat(s) and Chain(s). Dispenser 10: Dispenser I D: D Dispenser Containment Sensor(s). Model: 0 Dis(l(.'IISCI' Containment Sc!lo,<lr(s). Model: D Shear Valvc(s). D Shear Valvc(s). D Dispenser Containment Float(s) and ('hain(s). D Dispenser Containment Float(s) and Chain(s). Dispenser 10: Dispenser 10: 0 Dispcrt<;cr Containment Sensor(s). Model: 0 Dispenser C ontainrnent Scll~r(s). Model: 0 Shear Valvc(s). 0 Shear Valvc(s). 0 Dispenser C'ontauunent Float(s) and C'hanl(s). D Dr~(l(.'IISCI' Containment Float(s) and Chain(s). •Jfthe facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. C. Certification -I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a copy of the report; (clreck all tlrat app/J'}: [8] System set-up [8] Alarm ltistory report Technician Name Krist~her Karns Certification No.: B34106 Signature: ~4 '&.cA., License. No.: --'-80.:....4-=9-=0-=4 _____ _ Testing Company Name: Confidence UST Services, Inc. Phone No.: (800) 339-9930 Site Address: 2222 F Street, Bakersfield, CA 93301 Date ofTesting/Servicing: 12/19/2013 Page 1 of 3 Monitoring System Certification D. Results of Testing/Servicing Software Version Installed: 333.03 ~~~--------------------------- c he foll heckl· [8l Yes 0 No* Is the audible alarm operational? C8l Yes 0 No* Is the visual alarm operational? [8l Yes 0 No* Were all sensors visually inspected, functionally tested, and confirmed operational? C8l Yes 0 No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere with their proper operation? 0 Yes 0 No* If alarms arc relayed to a remote monitoring station, is all communications equipment (e.g., modem) C8l N/A operational? [8l Yes 0 No* For pressurized piping systems, docs the turbine automatically shut down if the piping secondary containment 0 N/A monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate positive shut-down? (Check all that apply) [8l Sumpffrench Sensors; 0 Dispenser Containment Sensors. Did you confirm positive shut-down due to leaks and sensor failure/disconnection? [8l Yes; 0 No. 0 Yes 0 No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e., no C8l N/A mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank fill point(s) and operating properly? lf so, at what percent of tank capacity does the alarm trigger? -61% 0 Yes* C8l No Was any monitoring equipment replaced? If yes, identifY specific sensors, probes, or other equipment replaced and list the manufacturer name and model for all replacement parts in Section E, below. 0 Yes* ~ No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that app~y) 0 Product; 0 Water. If yes, describe causes in Section E, below. C8l Yes 0 No* Was monitoring system set-up reviewed to ensure proper settings? Attach set up reports, if applicable 0 Yes C8l No* Is all monitoring equipment operational per manufacturer's specifications? *In Section E below, describe how and when these deficiencies were or will be corrected. E. Comments: Q-3 Reg. PLLD failed to catch leak. It appears to have air in the line. The parts will be ordered to make appropiate repairs. 91 OPW Direct Burial Spill Bucket failed and needs to be replaced. Page 2 of 3 Monitoring System Certification F. In-Tank Gauging I SIR Equipment: ~ Check this box if tank gauging is used only for inventory control. 0 Check this box if no tank gauging or SIR equipment is installed. This section must be completed if in-tank gauging equipment is used to petfonn leak detection monitoring. Complete the following checklist: ~Yes 0 No* Has all input wiring been inspected for proper entry and termination, including testing for ground faults? ~Yes 0 No* Were all tank gauging probes visually inspected for damage and residue buildup? ~Yes 0 No* Was accuracy of system product level readings tested? ~Yes 0 No* Was accuracy of system water level readings tested? ~Yes 0 No* Were all probes reinstalled properly? 181 Yes 0 No* Were all items on the equipment manufacturer's maintenance checklist completed? ~'In the Section H, below, describe how and when these deficiencies were or will be corrected. G. Line Leak Detectors (LLD): 0 Check this box ifLLDs are not installed. Comolete the ft ~Yes 0 No* For equipment start-up or annual equipment certification, was a leak simulated to verifY LLD performance? 0 N/A (Check all that apply) Simulated leak rate: ~ 3 g.p.h.; 0 0.1 g.p.h ; 0 0.2 g.p.h. 0 Yes ~No* Were all LLDs confirmed operational and accurate within regulatory requirements? ~Yes 0 No* Was the testing apparatus properly calibrated? 0 Yes 0 No* For mechanical LLDs, does the LLD restrict product flow if it detects a leak? ~ N/A ~Yes 0 No* For electronic LLDs, does the turbine automatically shut off if the LLD detects a leak? 0 N/A ~Yes 0 No* For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled 0 N/A or disconnected? ~Yes 0 No* For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system 0 N/A malfimctions or fails a test? ~Yes 0 No* For electronic LLDs, have all accessible wiring connections been visually inspected? 0 N/A ~Yes 0 No* Were all items on the equipment manufacturer's maintenance checklist completed? * In the Section H, below, describe how and when these deficiencies were or will be corrected. H. Comments: Q-3 reg. PLLD fa1led to detect leak. It appears to have a1r m the I me. I he parts have been ordred and we will rturn to make repa1rs and retest 87 Q-3 PLLD. Page 3 of 3 I Q I :PLlJS 0.20 GAL/HR RESULT: DEC 19.2013 1:33AM PASS Q 2:SUPER • 0.20 GAL/HR RESULT: DEC 19.2013 I :34Pl1 PASS .· I, A : . :.~ ~ Q 3:REGULAR ·t• ~ ~ ' 0.20 GAL/HR RESULT: DEC 19.2013 1 ~£25At-J PASS I I PRESSURE LINE LEAK ALARM Q 2:SUPER PLLD SHIJTDOWN ALARM DEC 19. 2013 9:51 AM ----SENSOR. ALARM -----L 4:SUPER STP STP SCR1P FUEL ALARM DEC 19. 2013 9:5t AN !\ 1: ;~ . • ·I( . i 11" PRESSUR~·; !£~ AJ,Jir.tl ~3:REG . ~fl"' ~·-",~; PLLD SH ltl Rf1 · DEC 19. ~ 11tl ·:~ .P~ AH \ ./' J ,;P. \ l'.\·' -----SEtSOR.A~RH -----L 6:REGULARJsrp· .. STPSlJ1P FUEL ALARM DEC 19, 2013 9:52 ~ PRESSURE LitlE LEAK ALARM Q l :PLUS PLLD SHIJTDOWII AUIRM DEC 19. 2013 9:52 AH -----SENSOR ALARM __ _,... L 2:PLUS STP STP SU1P FUEL ALARM DEC 19. 2013 9:52 AH RAHCO EXPRESS 2222 F STREET BAKERSFIELD CA 93301 661-324-1758 DEC 19. 2013 9:54 AM S\'STEJ1 STATUS REPORT L 2: FUEL ALARM L 4 :FUEL ALARM L 6:FUEL ALARI'l Q l :PLLD SHUTDOWN ALARM Q 2:PLLD SHIJTDCWtl ALARM Q 3:PLLD SHIJTDCWtl ALARM ltNENTORY REPORT T I :PLUS VOLlJ1E • I 668 GALS ULLAGE • 801 6 GALS 90Y. ULLAGE• 7047 GALS TC VOLUME • 1660 GALS HEIGHT • 20.31 HlCHES WATER VOL • 0 GALS WATER • 0.00 INCHES TEMP • 66.4 DEC F T 2:REGULAR VOLll1E • 4725 GALS ULLAGE • 4959 GALS 90Y. ULLAGE• 3990 GALS TC VOLUME • 4727 GALS HEIGHT • 43.25 INCHES WATER VOL • 0 G.ALS WATER ,. 0.00 ltiCHES TEMP • 59.3 DEC F T 3:SUPER VOLUHE .. 1384 GALS ULLAGE .. 8300 GALS 90Y. ULLAGE• 7331 GALS TC VOLlJ1E • 1375 GALS HEIGHT • 17.80 ltiCHES WATER VOL • 13 GALS WATER • 0. 77 ltiCHES TEMP • 69.0 DEC F X X X X X Et/0 X X X X X SOFTWARE REVISION LEVEL VERSION 333.03 SOFTWAREP 346333-100-D CREATED-13.02.12.10.26 S-MODULEP 330160-064-o ~~O~~T~~~NK T£STS ANNUAL I ti-TANX T£STS ISD/APM PLLD 0.10 AUTO 0.20 REPETITIV WPLLD 0.10 AUTO 0.20 REPETITIV S'ISTEM SETUP DEC 19. 2013 9:5~ AM SYSTEM UNITS u.s. SYSTEM LAtiGUACE EtiGLISH SYSTEM DATE/TIME FORMAT NON DO 'l'{'('( tm:MM:SS l<M RAHCO EXPRESS 2222 F STREET BAKERSFIELD CA 93301 661-324-1758 SHIFT TIME I : DISABLED SHIFT TIME 2 : DISABLED SHIFT TIME 3 : DISABLED SHIFT TIME 4 : DISABLED TANK PER TST NEEDED WRU DISABLED TANK AtiN TST tiEEDED WRU DISABLED LINE RE-ENABLE METHOD PASS LitlE TEST ---·-· LitlE PER TST NEEDED WRN DISABLED LitlE ANN TST NEEDED WRII DISABLED PRJ NT TC VOLlJMES ENABLED TEMP COHPEt&-\l'IOtl VALUE <DEG F >: 60.0 STICK HEIGHT OFFSET DISABLED ULLAGE: 9~: H-PROTOCOL DATA FORMAT HEIGHT PRECISIOU TEST DURATION HOURS: 12 0.20 GPH LINE TEST AUTO-cONFIRM: EIIABLEO 0.10 GPH LUIE TEST AUTO-cONF I RH: EliAS LED PRINT PRECISIOII LitlE TEST RESULTS: EtiABLEO DAYLIGHT SAVING TIME ENABLED START DATE HAR WEEK 2 SUN START TIME 2:00 AH END DATE NOV WEEK I SUtl END TINE 2:00AM R.E-DIRECT LOCAL PRWTOUT DISABLED EURO PROTOCOL PREFIX s SYSTEM SECURITY CODE : 000000 HAiflfENANCE HISTORY DISABLED TANK CHART SECURITY DISABLED CUSTOM ALARHS DISABLED SERVICE IIOTICE DISABLED ISO 3166 courrrRY CODE: VAPOR MONITORING TYPE CARB lSD MASS/DENSITY DISABLED FISCAL HEIGHT SECURITY DISABLED INVENTORY ALARMS UNITS COUFIG: STANDARD MAX OR LABEL: VOLLt1E HIGH PRODUCT: % MAX OVERFILL : ~; MAX DELIV NEEDED: ::.41AX LOW PRODUCT : VOLLt1E ALARM REDUCTION ENABLED CONMUIIICATIONS SETUP PORT SETTH~: COMM BOARD : l <RS-232> BAUD RATE : 9600 PARITY : ODD STOP BIT : 1 STOP DATA LENGTH: 7 DATA RS-232 SECURITY CODE : DISABLED CONM BOARD : 2 <ED lt1 > RS-232 SECURITY CODE : DISABLED COMM BOARD : 3 <RS-232> BAUD RATE : 9600 PARITY : NONE STOP BIT : I STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED AUTO TRANSMIT SETTINGS: AUTO LEAY. ALARM LIMIT DISABLED AUTO HIGH WATER LIMIT DISABLED AUTO OVERFILL LIMIT DISABLED AUTO LOW PROD~ DISABLED AUTO THEFT LIMIT DISABLED AUTO DELIVERY START DISABLED AUTO DELIVERY EIID DISABLED AUTO EXTERNAL I tiPUT ON DISABLED AUTO EXTERNAL 1 NPUT OFF DISABLED AUTO SENSOR FUEL ALARM DISABLED AUTO SENSOR WATER ALARM DISABLED AtrrO SENSOR OUT ALARM DISABLED RS-232 END OF MESSAGE DISABLED IN-TAIIK SETUP T 1 :PLUS PRODUCT CODE THERMAL COEFF TANK DIAMETER TAtiK PROFILE FULL VOL 66.8 INCH VOL 44,5 INCH VOL 22.3 INCH VOL 1 .000700 89.00 4PTS 9684 7861 4904 1898 FLOAT SIZE: 4.0 Ill. WATER HltUM~ : 0.200 WATER WARNIIIG : 2.0 HIGH WATER LIMIT! 3.0 WATER ALARM FILTER: LOW MAX OR LABEL VOLUME : 9684 HIGH PRODUCT Yo MAX : 95.0 <CALLOtiS> : 9200 OVERFILL LIMIT Y. MAX : 90.0 <GALLOIIS> : 8716 DELIVERY LIMIT :, MAX : 10.0 (CALLOIIS) : 968 LOW PROD~ VOLUME : 515 LEAK ALARM LIMIT: . 99 SUDDEN LOSS LIMIT! 50 TANK TILT : 3.02 PROBE OFFSET : o.oo SIPHON MANIFOLDED TAN!~ Til! NONE LINE MANIFOLDED TANKS TJI: NONE LEAK Hill PERIODIC: I~ LEAK HI tl AtltWAL : PERIODIC TEST TYPE 9Et3 lOY. 968 STAIIDARD AtiNUAL TEST .FAIL ·•' AlARM ~ISABLED P.ERIDDI~TEST·FAIL ALARM DISABLED CROSS TEST FAIL ALARM DISABLED Aim TEST AVERACitiG: OFF PER TEST AVERAGING: OFF TANK TEST NOTIFY: OFF TllK TST SIPHON BREAK:OFF DELIVERY DELAY : I HIN PUMP THRESHOLD : IO.OW. T 2:REGULAR PRODUCT CODE THERMAL COEFF TANK DIAMETER TANK PROFILE FULL VOL 66.8 INCH VOL 44.5 INCH VOL 22. 3 ltlCH VOL FLOAT SIZE: WATER MINIMUM : 2 .000700 89.00 4PTS 9684 7861 4904 1898 4.0 IN. 0.200 WATER WARNUIG : 2.0 HIGH WATER LIMIT! 3.0 WATER ALARM FILTER: LOW MAX OR LABEL VOLUME : 9684 HIGH PRODUCT ~' MAX : 95.0 <CALLOtiS) : 9200 OVERFILL LIMIT ~MAX : 90.0 <GALLONS> : 8716 DELIVERY LIHlT Y. MAX : 10.0 <GALLONS> : 969 LOW-PRODUCT VOLU1E : 515 LEAK ALARM LIMIT: 99 SUDDEN LOSS LIMIT: 50 TANK TILT : o.oo PROBE OFFSET : o.oo SIPHON MAtllFOLDED TANKS Til: NONE LitlE MANIFOLDED TANKS Til! NOliE LEAK Hill PERIODIC: LEAK HI N AIIUUAL : 10:; 969 I 0}; 968 PERIODIC TEST TYPE STAilDARD ANNUAL TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLEO CROSS TEST FAIL ALARM DISABLED AIIN TEST AVERAGitiG: OFF PER TEST AVERACUlG: OFF TANK TEST NOTIF"/: OFF TNK TST SIPHON BREAK:OFF DELIVERY DELAY : I MIN PUMP THRESHOLD : 1 0. OOV. T 3:SUPER PRODUCT CODE THERt1AL COEFF TANK DIAMETER TANK PROFILE FULL VOL 66,8 l~H VOL 44.5111CH VOL 22.3 It.'CH VOL FLOAT SIZE: WATER HlNINlJ1 : 3 ,000700 89.00 4 PTS 9684 7861 4904 1696 4.0 HI. 0.200 WATER WARtliNG : 2,0 HIGH WATER LIMIT: 3.0 WATER ALARM FILTER: LOW MAX OR LABEL VOLUIIE : 9684 HIGH PRODUCT !' HAX : 95.0 <GALLOIS) : 9200 OVERFILL LIMIT Y. MAX : 90.0 <CALLOtlS> : 8716 DELIVERY LIMIT ~MAX : 10.0 <GALLONS> : 969 LOW PRODUCT VOLUME : 515 LEAK ALARM LIMIT: 99 SUODEt~ LOSS LIMIT: 50 TAIIK TILT : 2.60 PROBE OFFSET : o.oo SIPHON MANIFOLDED TANt'.S Til: tiONE LINE MANIFOLDED TAIIKS Til: NONE LEAK MIN PERIODIC: LEAK MIN AlltiUAL : 10'4 969 IW. 968 PERIODIC TEST TYPE STANDARD AlltiUAL TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED GROSS TEST FAIL ALARM DISABLED Atltl TEST AVERAGttiG: OFF PER TEST AVERAGING: OFF TANK TEST NOTIFY: OFF TtiK TST SIPHON BREAK:OFF DELIVERY DELAY : I MIN PLV1P THRESHOLD : 10.00'; LEAK TEST METHOD TEST ON DATE : ALL TANK JUL 31. 2013 START TIME : 2:30 AM TEST RATE !D.20 CAL/HR DURATION : 2 HOURS , TST EARLY STOP!DISABLED LEAK TEST REPORT FORMAT ENHANCED PRESSURE LitlE LEAK SETUP Q 1 !PLUS TVP:2.0 lfl STEEL LINE LENGTH: 125 FEET 0,20 GPH TEST: REPETITIV 0.10 GPH TEST: DISABLED SHUTDOWN RATE: 3,0 GPH LOW PRESSURE SHUTOFF:NO LOW PRESSURE : 0 PSI T I:PLUS DISPENSE MODE: STANDARD SElSOR: HIGH PRESSURE PRESSURE OFFSET: O,OPSI MECHANICAL BLENDER: 110 Q 2:SUPER TVJ>:2.0 IN STEEL LINE LENGTH: 125 FEET 0.20 GPH TEST: REPETITIV 0, I 0 GPH TEST: A liTO SHUTDOWN RATE: 3.0 GPH LOW PRESSURE SHUTOFF:NO LOW PRESSURE : 0 PSI T 3:SUPER DISPENSE MODE: STANDARD SENSOR: HIGH PRESSURE PRESSURE OFFSET: O,OPSI MECHANICAL BLENDER: llO Q 3:REGULAR TVP:2,0 IN STEEL LitlE LENGTH: 125 FEET 0.20 GPH TEST: REPETITIV 0, I 0 GPH TEST: MAtiUAL SHUTDOWtl RATE: 3, 0 GPH LOW PRESSURE SHUTOFF:tiO LOW PRESSURE : 0 PSI T 2!REGULAR DISPENSE MODE: STANDARD SENSOR: HIGH PRESSURE PRESSURE OFFSET: O,OPSI MECHANICAL BLENDER: 110 LINE LEAK LOCKOUT SETUP LOCKOUT SCHEDULE DAILY START TINE: DISABLED STOP TIME : DISABLED LIQUID SENSOR SETUP L l !SUPER ANIIULAR TRI-STATE <SINGLE FLOAT> CATEGORY : AWWLAR SPACE L 2:PLUS STP TRI-STATE <SINGLE FLOAT> CATEGORY : STP SUHP L 3:REGULAR ANNULAR TRI-STATE <SINGLE FLOAT> CATEGORY : ANNULAR SPACE L 4 :SUPER STP TRI-STATE <SINGLE FLOAT> CATEGORY : STP SUMP L 5:PLUS AIIIIULAR TRI-STATE <SINGLE FLOAT> CATEGOR\' : AlliiULAR SPACE L 6:REGULAR STP TRI-STATE <SINGLE FLOAT> CATEGORY : STP SUMP PLLD LUIE DISABLE SETUP Q I :PLUS ltl-TANK ALARMS T I :HIGH WATER ALARM T 1 :LOW PRODUCT ALARM T 1 :PROBE Ol1T LIQUID SENSOR ALMS L 2:FUEL ALARM L 2 :SENSOR Ol1T ALARM L 5:SENSOR Ol1T ALARM L 2:SHORT ALARM L 4:SHORT ALARM lSD SITE ALARMS lSD CROSS PRES FAIL ISO OECRD PRES FAIL lSD VAPOR LEAK FAIL lSD VP PRES FAIL ISO VP STATUS FAIL lSD SETUP FAIL lSD SENSOR OUT FAIL PC-ISO FAILURE lSD HOSE Al.ARf'S ALL!CROSS COLLECT FAIL ALL:DEGRO COLLECT FAIL ALL!FLOW COLLECT FAIL Q 2:SUPER IN-TANK ALARMS T 3:HICH WATER ALARM T 3!LOW PRODUCT ALARM T 3!PROBE OUT LIQUID SENSOR ALMS L &~:FUEL ALARM L I :SENSOR OUT ALARM L 4 :SENSOR OUT ALARM L I :SHORT ALARt1 lSD SITE ALARMS lSD CROSS PRES FAIL ISO DEGRO PRES FAIL lSD VAPOR LEAK FAIL lSD VP PRES FAIL ISO VP STATUS FAIL lSD SETUP FAIL ISO SENSOR OUT FAIL PC-lSD FAILURE lSD HOSE ALARMS ALL:CROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL Q 3:RECULAR 114-TAIIK ALARMS T 2:HICH WATER ALARM T 2!LOW PRODUCT ALARM T 2!PROBE OUT LIQUID SEilSOR ALMS L 6:FUEL ALARM L 3:SENSOR OUT ALARM L 6!SENSOR OUT ALARM lSD SITE ALARMS ISO CROSS PRES FAIL ISO DEGRD PRES FAIL ISO VAPOR LEAK FAIL ISO VP PRES FAIL ISO VP STATUS FAIL ISO SETUP FAIL ISO SENSOR OUT FAIL PC-lSD FAILURE ISO HOSE ALARMS ALL:CROSS COLLECT FAIL ALL!DECRD COLLECT FAIL ALL!FLOW COLLECT FAIL .SHARTSEtiSOR SETUP ·------------ -~:F.l..QJ.L I:IE'IT..ER. 1-2 • CATEGORY AIR FL~-M~ER ~ 2:FLOW METTER 3-4 CATEGORY AIR FLOW METER ~ 3 :PRESSURE SEtlSOR CATEGORY VAPOR PRESSURE EVR/ISD SETUP EVR TYPE: VACUUM ASSIST VACUUM ASSIST TYPE HEALY VAC N02ZLE A/L RAtiGE MAX: 1.15 MltH 0,95 VAPOR PROCESSOR TYPE NONE ANALYSIS TIMES TIME! I :49 PM DELAY MINllfES: ACCEPT HIGH ORVR: DISABLED lSD HOSE TABLE ID FP FL HL AA RR ------------------------01 33 01 02 01 00 02 34 02 02 01 00 03 35 03 02 02 00 04 00 04 02 02 00 ISO AIRFLOW METER MAP ID SERIAL lll.t1 LABEL I 20340 2 23389 FLOW METTE FLOW METTE ISO FUEL GRADE HOSE MAP I 2 3 4 FP HHH HHH MHH MHH AA 00 204 004 104 u u 2 I 33 201 001 101 U U I 34 202 002 102 u u 1 35 203 003 103 u u 2 LABEL TABLE 1 UNASSIGNED 2 BLEND 3 REGULAR 4 MID GRADE 5 PREl1ILt1 6 COLO 7 BRONZE 8 SILVER 9 BLEND2 10 BLEND4 SOFTWARE REVISION LEVEL VERSIOfl 333.03 SOFTWARE# 346333-100-D CREATED-13.02.12.10.26 S-MODULE# 330160-064-a S'ISTEl1 FEATURES: PERIODIC IN-TANK TESTS ANNUAL I N-TAtiK TESTS ISD/APM PLLD 0.10 AUTO 0.20 REPETITIV WPLLD 0.10 AUTO 0.20 REPETITIV ALARM HISTORY REPORT -----· SEt-ISOR ALARM ----- L I :SUPER AtHIULAR ANNULAR SPACE FUEL ALARM AUG 23. 2013 9!41 AH SENSOR OUT ALARM AUG 23. 2013 9:25 AH FUEL ALARM AUG 23. 2013 9:20 AH M M M M M END M M M M M ALARM HISTORY REPORT -----SENSOR ALARH -----L 2!PLUS STP STP SUMP FUEL ALARM DEC 19. 2013 9:52 AH SENSOR OUT ALARM ! AUG 23. 2013 9:25 AH I FUEL ALARM AUG 23. 2013 9!14 AH M M M M M END * ~ ~ * * ALAJ(H HISTORY REPORT -----SENSOR ALARM -----L 3:REGULAR AtltlULAR ANNULAR SPACE FUEL ALARM AUG 23. 2013 9:39 AM SENSOR OUT ALARM AUG 23. 2013 9:25 AM FUEL ALARM AUG 23. 2013 9!21 AH M M M M )( END )( )( )( )( )( ALARM HISTORY REPORT -----SENSOR ALARM -----L 4 :SUPER STP STP SlklP FUEL ALARM DEC 19. 2013 9:51 AH FUEL ALARM NOV 21. 2013 7:40PM SENSOR OUT ALARM AUG 23. 2013 9!25 AH ---·- M M M M M END M K M M M ALARM HISTORY REPORT ---SENSOR ALARM ---L 5:PLUS ANNULAR AtlflULAR SPACE FUEL ALARM AUG 23. 2013 10!04 AM FUEL ALARM AUC 23. 2013 10!04 AM FUEL ALARM AUC 23. 2013 9!38 AH M M * M M EtiD M M * K K ALARM HISTORY REPORT ----SEtSOR ALARM --L 6:REGULAR STP STP SIJ1P FUEL ALARM DEC 19. 2013 9:52 AM --"""'··--FUEL ALARM NOV 21. 2013 9:39PM FUEL ALARM NOV 21. 2013 7!57 PM M M M )( M END K M M )( )( L RAHCO EXPRESS 2222 F STREET BA~ERSFIELD CA 9~~01 661-324-1758 DEC 19. 2013 9:56AM PRESSURE LitlE LEAK TEST HISTORY Q I :PLUS LAST 3.0 GAI../HR PASS: DEC 19. 2013 9:54 AH FIRST 0.20 GAL/HR PASS EACH HOtlTH: DEC 1. 2013 10!40 PM t~V J, 2013 12:23 AH OCT J, 2013 12!38 AH SEP J, 2013 11!04 PM AUG 1. 2013 11!55 PM JUL 31. 2013 6:09PM FIRST 0.10 GAI../HR PASS EACH MONTH: l( )( M )( )( EtlD )( )( )( )( )( RAHCO EXPRESS 2222 F STREET BAKERSFIELD CA 93301 661-324-1759 DEC 19. 2013 9:56AM PRESSURE LINE LEAK TEST HISTORY Q 2:SUPER LAST 3,0 GAI../HR PASS: DEC 19. 2013 8:55 AH FIRST o.:m GAI../HR PASS EACH HOtlTH: DEC 1. 2013 12 08 AM NOV t. 2013 I 08 AM OCT 1. 2013 12 38 AH SEP 1. 2013 10 49 FN AUG 1. 2013 11 56 PH JUL 31. 2013 6 09 PH FIRST 0.10 CAL/HR PASS EACH MONTH: JUL 31. 2013 11!30 ~~ )( * )( M * EtiD M )( * * K RAMCO EXPRESS 2222 F STREET BAKERSFIELD CA 9:1:101 661-324-1758 DEC 19. 2013 9:56AM PRESSURE LlflE LEAK TEST HISTORY Q 3:REGULAR LAST 3.0 CAL/HR PASS: DEC 19. 2013 9:53AM FIRST 0.20 GAL/HR PASS EACH HONTH: DEC 1. 2013 1 47 AM NOV 1. 2013 1 23 AM OCT 1. 2013 3 3:1 AM SEP 1. 2013 2 09 AM AUG 3. 2013 2 23 AM Jut 31. 2013 6 25 PH FIRST 0.10 GAL/HR PASS EACH MONTH: M M M M M E~D M M M M M -----SENSOR ALARM -----L 5:PLUS AWIULAR ANNULAR SPACE FUEL ALARM DEC 19. 2013 9:59AM -----SEtSOR ALARM ----L 3:ijEGULAR ANNULAR ANNULAR SPACE- FUEL ALARM • -.DEC 19. 2013 10:01 AH ~~: -----SENSOR ALARM -----• L 1 :SUPER AIINULAR ANNULAR SPACE FUEL ALARM DEC 19. 2013 10:03 AM L PRESSURE LINE u:AK ALARM Q 1 :PLUS PLLO SHUTDOWN ALARM DEC 19. 2013 10:15 AH -----SElSOR ALARM -----L 5:Pt.US ANIIULAR ANNULAR SPACE SENSOR OUT ALARH DEC 19. 2013 10:15 AM PRESSURE LINE LEAK ALARM Q 2:SUPER PU.D SHUTDOWN ALARM DEC 19. 2013 10:15 AM -----SEt:SOR ALARM -----L 1 :SUPER ANNULAR ANNULAR SPACE SElSOR OUT ALARM DEC 19. 2013 10:15 AM PRESSURE LINE LEAK ALARH Q 3:REGULAR PLLD SHUTDOWN ALARM DEC 19. 2013 10:15 AM ----SElSOR ALARM ----- L 6:REGU!.AR STP STP Sli1P SEtlSOR OUT ALARH DEC 19. 2013 10!15 AM -----SElSOR ALARM -----L 2:PLUS STP STP SU'\P SENSOR OUT ALARM DEC 19. 2013 10:15 AM -----SENSOR ALARM -----L 3:REGULAR ANNULAR ANNULAR SPACE SENSOR OUT ALARM DEC 19. 2013 10:15 AM -----SENSOR ALARM ----- L 4:SUPER STP STP SLtiP SENSOR OUT ALARM DEC 19. 2013 10:15 AM RAHCO EXPRESS 2222 F STREET BAKERSFIELD CA 93301 661-324-1758 DEC 19. 2013 10:17 AM SYSTEM STATUS REPORT L 1 :SENSOR OUT ALARM L 2 :SENSOR OUT ALARM L 3:SENSOR OUT ALARM L 4 :SENSOR OUT ALARM t. S:SENSOR OUT ALARM L 6:SEIISOR OUT ALARM Q 1 :PLLD SHUTDOWN ALARM Q 2:PLLD SHUTOOWt4 ALARM Q 3:PLLD SHUTDOWN ALARM PRESSURE LitlE LEAK ALARM Q 1 !PLUS GROSS LitlE FAIL DEC 19. 2013 10:43 AM PRESSURE LINE LEAY. ALARM Q I :PLUS PLLD SHUTDOWN AI.ARH DEC 19. 2013 10:43 AM PRESSURE LHIE LEAK AI.ARN Q 2:SUPER CROSS LINE FAIL DEC 19. 2013 10:47 AM PRESSURE LINE LEAK ALARM 0 2:SUPER PLLD SHUTDOWN ALARM DEC 19. 2013 10!47 PI-t PRESSURE LitlE LEAK DJAG DEC 19. 2013 10:54 Al-1 Q 3:REGULAR 3, 0 TEST PASSES ------------PON PI P2 DEC 19. 2013 10:53 AH 29.8 21.5 19.7 DEC 19. 2013 10:51 AM 29.8 18.8 15.4 DEC 19. 2013 10:38 AH 29.8 17.9 14.0 DEC 19. 2013 10:23 AH 22.0 22.0 22.0 DEC 19. 2013 8:53AM 30.3 21.6 21.5 3.0 TEST FAILS ------------PON t~OV 8, 8.9 AUG 18. 30.5 PI P2 2013 I: 15 PM 9.-1 9.7 2013 10:11 AM 9.9 1.1 3.0 HI PRESSURE EVEilTS ------------PON PI P2 NO TEST DATA AVAILABLE d PRESSURE LitlE LEAl: DIAG DEC 19. 2013 10:55 AM Q I !PLUS 3,0 TEST PASSES PON PI P2 DEC 19. 2013 10!37 AM 39.0 21.3 21.0 DEC 19. 201'3 10:32 AM 43.0 21.4 21.1 DEC 19. 2013 10:22 AH 20.9 21.1 21.1 DEC 19· 2013 8:54 AH 39.1 21.2 20.9 DEC 19. 2013 8:43 AH 39,0 21.1 20.8 3.0 TEST FAILS ------------POU PI f'2 DEC 19. 2013 10:43 AP-I 28.7 13.4 6.9 3.0 HI PRESSURE EVEtlTS ------------PON PI P2 NO TEST DATA AVAILABLE PRESSURE LWE LEAl: DIAG DEC 19, 2013 10:55 AM Q 2!SUPER 3.0 TEST PASSES PON PI P2 DEC 19, 2013 10!37 AH 34.7 20.3 20.1 DEC 19. 2013 10!32 AH 36.1 20.4 20.1 DEC 19, 2013 10:22 AH 19.9 19.9 19.9 DEC 19. 2013 8:55 AH 38.7 20.3 20.1 DEC 19. 2013 8:44 AH 39.7 20.4 20.2 3.0 TEST FAILS PON PI P2 DEC 19. 2013 10:47 AM 29.2 10.2 5.2 3.0 HI PRESSURE EVEtlTS ------------PON PI P2 NO TEST DATA AVAILABLE PRESSURE I.WE LEAIC DIAG DEC 19. 2013 11:06 AH Q 3:REGUUtR 3.0 TEST PASSES POtl PI P2 DEC 19. 2013 11:05 AM 29.9 20.1 17.7 DEC 19. 2013 10:53 AH 29.8 21.5 19.7 DEC 19, 2013 10:51 AM 29.8 18.8 15.4 DEC 19. 2013 10:38 AH 29.8 17.9 14.0 DEC 19. 2013 10:23 AH 22.0 22.0 22.0 3.0 TEST FAILS PON PI P2 NOV 8. 2013 1:15 PH 8,9 9.4 9.7 AUC 18. 2013 10:11 AM 30.5 9.9 1.1 3.0 HI PRESSURE EVEtlTS PON PI P2 NO TEST DATA AVA I !.ABLE RAHCO EXPRESS 2222 F STREET BAJ<ERSFIELD CA 93301 __ 661-324-1758 -·--·- DEC 19, 2013 II :45 AM S'IST£11 STATUS REPORT Q I :GROSS !.HIE FAIL Q I :PLLD SHUTDOWN ALARM Q 2:GROSS LINE FAIL Q 2 :PLI.O SHUTDOIJil ALARM RAMCO EXPRESS 2222 F STREET BAKERSFIELD CA 93301 661-324-1756 DEC 19. 2013 11:48 AH SYSTEM STATUS REPORT AlL FUNCTIOUS NORW\1. RAMCO EXPRESS 2222 F STREET BAKERSFIELD CA 93301 661-324-1758 DEC 19. 2013 11!48 AH SYSTEM STATU$ P.EF'ORT ALL futlCTlONS tiORtii-\L SWRCB, January 2006 Spill Bucket Testing Report Form This form is intended for use by contractors pe1jonning annual testing of UST spill containment stmctllres. The completed fonn and prinrows from tests(!( applicable), should be prOI'ided to thefacility ownedoperatorfor submittal to the local regulatOI)' agency. 1. FACILITY INFORMATION Facility Name: Ramco Ex ress I Date ofTestins: 12/19/2013 Facility Address: 2222 F Street Bakersfield, CA 93301 Facility Contact: Rami I Phone: 818-339-7288 Date Local Agency Was Notified of Testing: 12/13/13 Name of Local Agency Inspector (if present during testing): Emie Medina 2. TESTING CONTRACTOR INFORMATION Company Name: Confidence UST Services Technician Conducting Test: Kristopher Kams Credentials1: IRl CSLB Contractor IRl ICC Service Tech. IRI SWRCB Tank Tester 0 Other (Specify) License Number(s): CSLB# 804904 ICC# 5264406-UT IT# 09-1743 - 3. SPILL BUCKET TESTING INFORMATION Test Method Used: Lake IRl Hydrostatic 0 Vacuum I l Other Test Equipment Used: Lake Test Equipment Resolution: 0.0625" Identify Spill Bucket (By Tank 1 Regular 2 Plus 3 Super 4 Number, Stored Product, etc.) IRl Direct Bury IRl Direct Bury IRl Direct Bury 0 Direct Bury Bucket Installation Type: 0 Contained in Sump Contained in Sump ' Contained in Sump r Contained in Sump 1 Bucket Diameter: 12.00" 12.00" 12.00" Bucket Depth: 11.25" 11.25'' 11.25" Wait time between applying 5min. 5m in. 5rnin. vacuum/water and start of test: Test Start Time {T1): 9:00am 9:00am 9:00am Initial Reading {R1): I 0.00" 9. 75" 10.00" Test End Time {TF): !O:OOam I O:OOam I O:OOam Final Reading (~:): 10.00" 9.75" 4.00" Test Duration (TF-T1): I Hour I Hour I !lour Change in Reading (Rf-R1): 0.00" 0.00" 6.00" Pass/Fail Threshold or 0.0625" 0.0625" 0.0625" Criteria: Test Result: X Pass OFail X Pass 0 Fail 0 Pass X Fail 0 Pass OFail Comments -(include i11(onnation on repairs made prior to testing, and recommendedfol!oll'-upforfailed tests) 91 OPW Direct Burial Spill Bucket failed and needs to be replaced. CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING TillS TESTING I hereby certify that all the information con ained in_tl is report is true, accurate, and in full compliance with legal requirement.\: Technician's Signature: Date: 12/19/2013 1 Stale laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements may be more stringent. i • Gl G • ·D. d,uns d!S ,;,tn~ 0 Gl G 0 r/£ JeSU'di!l] dtun~ diS Jel!l!>lj ,~, 1: Q G l{lO(o' Z/1 dwns dlS snld J?suariSI() QiOUWli ,.;g c fJS =! ~l\'=~ on.:=s 10H61fJ Pl''1im1ea J·:.!u;s 6Cr =t :~Gtl) :J lZZZ ~~:v· s~z =£ ss~1Jq o;lJelj YliJ'.'•S 0' 3=(' 1ou~d loqpcp<«A = r