HomeMy WebLinkAbout2011 RESULTSMONITORING SYSTEM CERTIFICATIONS f
For Use By All Jurisdictions ,Within the State of California
.Authority Cited. Chapter 6 7, Health and Safety Code; Chapter 16,.Division 3, Title 23; California Code of Regulations �
This form must be used to document testing and servicing of monitoring equipment. AKparate certification or report must be prepared for each
monitoring system control. panel by the technician who performs the work. A copy of this form must'be provided to the tank system owner /operator.
The.owner /operator must submit a copy of this form to. the local agency regulating UST systems within.30 days of test date.
A. General Information
Facility Name: CHEVRON Bldg. No.:
Site Address: 1999 TAFT HWY City BAKERSFIELD Zip:
Facility Contact Person: Contact Phone No.:
Make /Model of Monitoring System: TLS -350 INSPECTOR ON -SITE LYDIA Date of Testing/Servicing:. 7114/2011
B. Inventory of Equipment Tested/Certified
Check the appropriate boxes to indicate stiecific equivntent ins ted/serAced:
Tank.ID: UNL87
Tank 113: PREM91
E In -Tank Gauging Probe.
Model: MAGI .
E In -Tank Gauging Probe, Model: MAGI
® Annular Space or Vault Sensor.
Model,: 409 ,
® Annular Spaoc or Vault Sensor. Model: 409
® Piping Sump/ Trench Sensor(s).
Model: 208
® Piping Sump / Trench Sensor(s). Model: 208
E Fill Sump Sensor(s).
Model: NO SENSOR
E Fill Sump Sensor(s), Model: NO SENSOR
E Mechanical Line Leak Detector.
Model: FX1V
® Mechanical.Liri LeA..Detector. Model: FX1V
❑Electronic Line Leak Detector.
Model:
❑ Electronic Line Leak Detector. Model:
❑ Tank Overfill / High - Level Sensor.
Model:
❑ Tank Overfill /High -Level Sensor.. Model:
❑ Other (specify equipment type and model in Section E.on Page 2).
❑ Other (specify equipment type and model, in Section E on Page 2).
Tank ID: DIESEL
Tank ID:
® In -Tank Gauging Probe.
Model: MAGI
❑ In -Tank Gauging Probe. Model:
® Annular Space or Vault Sensor.
Model: 409
❑ Annular Space or Vault Sensor. Model:
Piping Sump / Trench Sensor(s).
Model: 208
❑ Piping Sump) Trench Sensor(s). Model:
® Fill Sump Sensor(s):
Model: NO SENSOR
❑ Fill Sump Sensor(s). Model:
® Mechanical Line Leak Detector.
Model: FX1 DV
❑ Mechanical Line Leak Detector. Model:
❑ Electronic Line Leak Detector.
Model:
❑ Electronic Line. Leak Detector. Model:
❑Tank Overfill / High -Level Sensor.
Model:
❑ Tank Overfill / High -Level Sensor.: Model:
❑ Other (specify equipment type and model in Section E on Page 2).
❑ Other (specify equipmepttype and model in Section E on Page 2).
Dispenser ID.: 1 -2
Dispenser ID: 1-4
E Dispenser Containment Sensor(s).
Model: 361
0 Dispenser Containment Sensor(s). Model: 351
®,Shear Valve(s).
Shear Valve(s).
❑ Dispenser Containment Float(s) and Chain(s).
❑ Dispenser Containment Float(s) and Chain(s).
Dispenser ID: 5-6
Dispenser ID: 74
® Dispenser Containment Sensor(s).
Model: 361
E Dispenser Containment Sensor(s). Model: 351
®Shear Valve(s).
® Shear Valve(s).
❑ Dispenser Containment Float(s) and Chain(s).
❑ Dispenser Containment Floats) and Chain(s).
Dispenser ID; 9-10
Dispenser 1D: 11 -12.
E Dispenser Containment Sensor(s).
Model: 351
® Dispenser Containment Sensor(s). Model: 361
E Shear Valve(s).
® Shear Valve(s).
❑ Dispenser Containment Float(s) and Chain(s).
❑Dispenser Containment Float(s) and Chain(s).
*If the facility contains, more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility.
C. Certificition - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'
guidelines. Attached to this Certification is information (e.g. manufacturers' checklists). necessary to verify that this information is
correct and a Plot Plan showing the layout of monitoring equipment. For any equt mentcapable of generating such reports, I have also
attached a copy of the report; (check all that apply): 0 System set -up Alarm history report
Technician Name (print): RICHARD MASON Signature:
Certification. No.: B36880152978574JC License. No. C6fD40 .809850
Testing Company Name: RICH ENVIRONMENTAL Phone No.: (661).392-8687
Testing Company Address: 5643 BROOKS CT. BAKERSFIELD, CA 93308 Date of Testing/Servicing: 7114111
Page .,1 of 4
IIN -036 —1/4 www.unidoeLorg Rev. 01/17/08
Monitoring System Certification
D. Results of Testing/Servicing
Software Version Installed: 329.01
rmmnlete the fnilnwino rheekiict!
Wt§554 /0"',
• Yes
❑ No*
Is the audible.alarm operational?
• Yes
❑ No*
Is the visual alarm operational?
E Yes
p No*
Were all sensors visually inspected, .functionally tested, and confirmed operational?
E Yes
No*
Were all sensors installed at-lowest point of secondary. containment and positioned so that. other equipment will
not interfere with their proper operation?
p Yes
❑ No*
If alarms are relayed to a remote monitoring station, is all communications equipment (e.g., modem)
E N/A
operational?
E Yes
❑ No*
For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment
❑ N/A
monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate
positive shut -down? (Check all that apply) .E'Sump/Trench Sensors; ❑ Dispenser Containment Sensors.
Did you confirm positive shut -down due to leaks.ld sensor failure /disconnection? E Yes; ❑ No.
❑. Yes
❑ No*
For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e., no
E N/A
mechanical overfill prevention valve is installed), is the :overfill - warning alarm visible tand audible at the. tank
fill point(s) and operating properly? If so, at what percent of tank capacity does the alarm trigger? %
E Yes*
❑ No
Was any monitoring equipment replaced? If yes „identify specific sensors, probes, or other equipment replaced
and list the manufacturer name and model for all replacement parts in Section E, below.
❑ Yes*
E No
Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply)
❑ Product; ❑ Water. If yes, describe causes in Section E, below.
® Yes
p No*
Was monitoring system set =up reviewed to ensure proper settings? Attach set up reports, if applicable
® Yes
[] No*
Is all.monitoring equipment operational . per.manufacturer's specifications?
* In Section E below, describe how and when these:deticiencies were or will be corrected.
E. Comments:
Page 2 of 4
UN- 036 — 2/4 www.unidomorg Rev. 01 /17/08
Monitoring System. Certification
F. In-Tank Gauging / SIR Equipment:. ® Check this box if tank gauging is used only for inventory control.
❑ Check this box if no tank gauging or SIR equipment is installed.
This section must be completed if in-tank gauging equipment is used to perform leak detection monitoring.
Complete the following checklist:
❑ Yes
❑ No*
Has.all input wiring been inspected for proper entry'and termination, including testing for ground faults?
❑ Yes
❑ No*
Were all tank gauging, probes visually inspected for:damage and residue buildup?
• Yes
❑ No*
Was accuracy of system product, level readings tested?
• Yes
❑ No*
Was accuracy of system water level readings tested?
• Yes
❑ No*
Were all probes reinstalled properly?
❑ Yes
❑ No*
Were.all items on the equipment manufacturer's maintenance checklist completed?
* In Section H, below, describe'.how and when these deficiencies were or will be corrected.
G. Line Leak Detectors (LLD): ❑ Check this box if LLDs are'not installed.
COmDlete the followins checklist!
® Yes
❑ No*
For equipment start -up or annual equipment certification, was a. leak simulated'to verify LLD performance?
❑ N/A
(Check all. that apply) Simulated leak rate: ;3 !g.p.h.;, . ❑ 0.1 g.p.h ; ❑ 0.Z g;p.h.
• Yes
No*
Were all LLDs confirmed operational and accurate within regulatory requirements?
N Yes
❑ No*
Was the testing apparatus properly calibrated?
• Yes
p No*
For mechanical LLDs, does the LLD restrict product flow if it detects a leak?
❑ N/A
❑ Yes
❑ No*
For electronic LLDs, does the turbine automatically shutoff if the LLD detects a leak?
® N/A
❑ Yes
p..No *'
For electronic LLDs, doe's -the turbine automatically shutoff if any portion of the monitoring system is disabled
® N/A
or disconnected?
❑ Yes
❑ No*
For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions
® N/A
or fails a test?
❑ Yes
p No*
For electronic LLDs, have all accessible wiring connections been visually inspected?
® N/A
® Yes
[j No"
Were all items on the equipment manufacturer's maintenance. checklist completed?
* In Section H, below, describe how and when these deficiencies were or Will be corrected.
H. Comments: DIESEL LINE LEAK DETECTOR FAILED. I REPLACED WITH NEW AND RETESTED - _PASSED.
Page 3 of 4
UN- 036 — 314 www.unidomorg
Rev. 01/17/08
i
s.
Monitoring System Certification
' Site Addmss: (9 q q
UST Monitoriniz Site Plan
Y. A cC , cam. ci v3(
. ---- - - - - -� - --- - - - - -- -----------------
: ( -- - - - -- - - - -- - - - - - - -- -- -.
-- ----- - - - - -- --------- •: : -
- - - - - --`
- -_
r - - - - - - -- - - - -- - -- - - - r
- :::: : :- - --
----- - ....
-- -- - - -- -
--- - - - - - - -- - - - - - - - - - - -- - -
- - - - - - - - - - - - - - - - - - - - - - - - -- - - -- - -- -- - - - - --
- - - - - - - - -- - -- LO _ - -- - - - - -- •-
• - r • w - - _ • - _ r _ • - - . . - _ - - -. - - . - - - - - - - - r - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - r . . . . . . - - -
- - - - - - - - - - - - - - - - - • . . _. r _ _ - • r - - - - _ - - - _ - .- - . _ _
- • �- - - - - - - - - - - - - - - - - - - - r - - - - _ r . . . r . . _ . . . . . . . . - _ .
- • - - : : : - - - - - - - - - - - - -. - - - - - - - - - -
-
. . . _ . . - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - . . . . . . . . - - - - - - - - - - - - - - - -. w r
Date map was dra; nL
br-US902!
o
If you already have a diagram that shows all required information, you may include it, rather than this page, with your
Monitoring System Certification On your site plan, show the general layout oftanks and piping. Clearly identify
locations of the. following equipment, if installed: monitoring system control panels; sensors monitoring tank annular
spaces, sumps, dispenser pans, spill containers, orother secondary containment areas; mechanical or electronic line leak
detectors; and in -tank liquid levol probes (if used for leak detection). In the`space provided, note the date this Site-Plan
was prepared. .
Page q of 05100
SWRCB,.January 2006
Spill Bucket Testing. Report Form
This form is intended for use by contractors performing annual testing. of UST •spill containment structures. The completed form and
printouts from tests (f applicable), should be provided to the facility owner /operator for submittal. to the local regulatory agency.
1.. FACELITY INFORMATION
Facility Name: CHEVRON
Date of Testing: 7/14/11
Facility Address: 1999 TAFT HWY, BAKERFIELD,.CA
Facility Contact:
Phone:
Date Local Agency Was Notified of Testing: 6%13/11
Name of Local Agency inspector (i(present during testing)- ESTHER DURAN
2. TESTING C'ONTRAC'TOR INFORMATION
Company Name: RICH ENVIRONMENTAL,
Technician Conducting Test: RICHARD MASON
Credentials: 0 CSLB Contractor X.ICC Service Tech. 0 SWRCB Tank Tester C Other (Specify)
License Number(s): 5297857 -UT
3. SPILL BUCKET TESTING INFORMATION
Test Method Used: X Hydrostatic 0.Vacuum q Other
Test Equipment Used: VISUAL
Equipment Resolution: 0'
Identify Spill Bucket (By Tank
Number, Stored Product, etc.)
UE
1
z
PREM91
3:.,
DIESEL
q
Bucket Installation Type:
0 Direct Bury
X Contained in.Sum
0 Direct Bury
X Contained in Sum
0 Direct Bury
X Contained in Sum
b Direct Bury
0 Contained, in Sum
Bucket Diameter,
12"
12"
12"
Bucket Depth:
16"
16"
16"
Wait time between applying
Vacuum/water and start of test:
30 MIN
30 MIN
30 MIN -
Test Start.Time (Ti):
9:00
9:00
9:00
Initial Reading (111):
10"
10"
10"
Test End Time (TF):
10:00
:10:00
10:00
Final Reading (RF):
10
10"
lo,,
Test Duration (TF — TO:
]-HOUR
1 -HOUR
1 -HOUR
Change in Reading'(RF- Ri):
0
i1 ..
0
Pass/Fail Threshold or
Criteria:
+/_0.00
+/- 0:00
+/- 0:00
Comments -- (include information on repairs:made prior to testing, and recommended follow =up for failed tests) .:i
CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING
I herebycertify that, all the information contalned in this report is true, accurate, and in full compliance with legal requirements.
Technician's Signature: '' Date: 7/14/11
' State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local' requirements
may be more stringent.
RICH ENVIRONMENTAL
5643 BROOKS CT. BAKERSFIELD, CA. 93308
OFFICE (661)392 -8687 FAX (661)392 -0621
PRODUCT LINE LEAK DETECTOR TEST
WORK SHEET
W /0#:
FACILITY NAME: TAFT HWY CHEVRON
FACILITY ADDRESS: 1999 TAFT HWY. BAKERFIELD.
PRODUCT LINE TYPE: PRESSURE
PRODUCT
LEAK DETECTOR TYPE
TEST
TRIP
PASS
BELOW
P.S.I.
OR
SERIAL NUMBER
3 G.P.H.
FAIL
UNL87
L/D TYPE: MECHANICAL
YES
10
PASS
SERIAL # RED JACKET
PEM91
L/D TYPE.- MECHANICAL
YES
10
PASS
SERIAL # .RED JACKET
DIESEL
LID TYPE: MECHANICAL.
'NO
0
FAIL
SERIAL # RED JACKET
DIESEL
L/D TYPE: RED JACKET
YES
10
PASS
SERIAL # 7423
I CERTIFY THE ABOVE TESTS WERE CONDUCTED ON THIS DATE ACCORDING TO RED
JACKET PUMPS FIELD TEST APPARATUS TESTING PROCEDURE AND LINUTATIONS.
THE MECHANICAL LEAK DETECTOR TEST -PASS /FAIL IS DETERMINED BY USING A
LOW FLOW THRESHOLD TRIP RATE OF 3 GALLONS PER HOUR OR LESS AT 10 P.S.I. I
ACKNOWLEDGE: THAT ALL DATA COLLECTED IS.-TRUE AND CORRECT TO THE BEST
OF MY KNOWLEDGE.
TECHNICIAN RICHARD MASON
SIGNATURE: �r1l
DATE: 7/14/11
EVR %ISI1 SETUP
�sLARM HIc,TORy
8MARTSEN84R .SETUP
REPORT
- - - - - _ _ _
EVR TYPE: BALANCE
L
F;NNULAA
_
1 : VAPOR PRESSURE
CATEGORY
BALANCE NOZZLE TYPE.
SPAt -E
OR
VAPOR .PRESSURE
VST
JUL OUT
JUL 14, 2011
1 10:05
2:CANISTER
VAPOR PROCESSOR T'PE
AM
FU! L ALARM
CATEGORY •VAPOR VALVE
VEEDER —ROOT POLISHER
•JUL 14, 2011
8.:ATM
9:57 AM
CATEGORY ATM P SENSOR
ANALYSIti TIMES
FEBU26r)�TA WA
s 9:DISP
TIME: TIME: 11:59 PM
2011, 6:4?
I1 -12
CATEGORY
DELAY MINUTES: 1
A�1
AIR FLOW METER
ALARM HISTORY REPORT
310 -DISP 5 -6
CATEGORY
ACCEPT HIGH ORVR:
AIR FLOW METER
ENABLED
-- SENSOR ALARM - -- --
L 2.:91 ANN
511:DISP 3 -4
ISD HOSE TABLE
ANNULAR SPACE
CATEGORY AIR FLOW METER
ID FP FL HL. .AA
SENSOR OUT ALARM
JUL 1.4, 2011 10:05 AM
s12:DISP 9_10
01 01 01 02 06
.
CATEGORY AIR FLOW METER
02 02 02 02 06
FUEL ALARM
JUL 14, 2011 9.:56 AM
s19'DISP 7 -8
03 03 03 02 03
04 04 04 02 03
CATEGORY AIR FLOW METER
05 05 05 02 02
-S14:DISP 1 -2
06 UU. 06 02 02
07 07 07 02 05
CATEGORY AIR FLOW METER
08. 08: 06 02 05 .
09 09 02 04
REPORT
09
Akhry .NISTi1k`1.
--
10 16 10 02 04
�LHF.M --
11 UU 11 02 01
BERABOR
-- UIESEL P11414
12 UU .12 02 01
L 3 ctiACE
A�'Rtry
1Er
5CF OU"t
R 2011 10:05 HM
ISD AIRFLOW METER MA
JUL
rMG SETUP
ID SERIAL NUM LABEL
10 X00 Ao
PMC VERSION: 01.03
-- - --
1 390119 DISP 1
DULL IA4LHk1011
? 42032 DISP 5
VAPOR,PROCESSOR TYPE
•3 42036 DISP 3
VEEDER- ROOT.POLISHER
4 39004 DISP 9
5 42031 DISP 7
6.42030 DISP 1
ALARM HISTORY REPORT
ISD FUEL GRADE HOSE
1 3 4
- -_ -- SEIISOR ALARM -_ - =-
FP MHH 'MHH MHH MHH A
L 4:87 STP
--------------------
STP Ste'
01 201.901 101 U U
SENSOR OUT ALAR9
JUL 1.4., 2011.10 :05 AM
SOFTWARE REVISION LEVEL
VERSION
02 202 902 102 U U
03.203'.3 N 163 903
FUEL ALARM
330.01
SOFTWARE# 34.6330- 100 -B
CREATED
04 204 3 N.904 104
5 05 20 105 905 U U
JUL 14. 2011 9:50 AM
10.07.23.17.,25
06 2.0 9-U 1 U U U
GETUP DATA WARNING
S-•MODULF# 3J0160 -004 -
SYSTEM FEATURES. a
:
07 207 107 907 U U
08 208 908 10$ U U
MAR ,B. 2011 6:09 PM
PERIODIC IN —TANK TESTS
09 209 109 909 U U
ANNUAL IN -TANK TESTS
16 210 91.0 110 U U
ISD
172U 1 U 3 U 9 U
16 2 U 9 U 1 U 3 U
LABEL TABLE
ALARM RT TQRy REPORT
--------------------
1: UNASSIGNED
- - - -- SrZ.OR 'ALARM - - - --
2: BLEND3
ALARM H I STOpli, k>:r °«x 1'
L 6 : D I ESEL STP:
3: REGULAR
STP SUMP
4: MID GRADE
- - -- SENSOR ALARM - - - --
SENSOR OUT ALARM
5: PREMIUM
L 5:91 STP
JUL 14, 2011 •10':05 AM
6: GOLD
STP SUMP
7: BRONZE
SENSOR OUT ALARM
FUEL ALAR11
8: SILVER
JUL 14, 2011 10:05 All
JUL 14. 2011 9:53 AM
9: BLEND2
T E:PREM -9i
PRODUCT CODE
T 3-DIESEL.
THERMAL CUEFF :.00
LEA1+
PRODUCT CODE
3
TANK DIAMETER 12
-TEST METHOD
THERMAL .CUEFF
:.000450
TANK PROFILE 4
TEST �3NJ DATE - -
TANK DIAMETER
TANK PROFILE
y6.,l70
FULL VOL 1
90.0 I NCH 'VOL 1
JUL 201.0
23. ' ALL TANK
START
FULL VOL
4 PTS
7829
60.0 INCH VOL
TIME
TEST RATE ; DISABLED
72.0 INCH "VOL
4.8.0
30.0 1NC,,H VOL ;
DURATION 220 GAL./HR
INCH VOL
24.0 INCH VOL
6652
HOURS
TST EARLY
1540
FLOAT SIZE: 4.0
STOP;DISABLED
LEAK
FLOAT SIZE:
4 114.
WATER WARNING
TEST REPO RT' FpR1NFjT
WATER
,.0
HIGH WATER LIMIT:
WARNING
N0RMAL
HIGH WATER LIMIT :
2.0
3,. 0
MAX OR LABEL VOL: 1
OVERFILL LIMIT
MAX OR LABEL VOL:
7829
1
OVERFILL LIMIT
90y
HIu'H PRODUCT
HIr,H PRODUCT
7046
95%
1
DEL.IVERY LIMIT
DELIVERY LIMIT
7437
•
10%
762
LOW PRODUCT
LEAK ALARM LIMIT:
LIQU1D SENSOR
LOW PRODUCT
LEAK
359
SUDDEN LOSS LIMIT:'
-
ALARM LIMIT:
TANK TILT
-SETUP
`
SUDDEN LOSS LIMIT:
50
PROBE OFFSET
- - -
L 1:87 ANN
TANK TILT
PROBE OFFSET '
0.00
TRI - -STATE tSIlvGLE FLOAT)
0.00
SIPHON MANIFOLDED TA
ANtVULAR SPAC)r
T #: NONE
S I PHON MAN I FOLDED
TANKS
LINE MAPJ I F vLI?ED TANK;
T #: NONE
T #: NONE
L 2:11
LINE MANIFOLDED TANKS
TRI -� ANN
T#: NONE
LATEGORA {S'INGLE FLOAT
LEAK MN PERIODIC.
: ANNULAR SPACE
LEAK MIN PERIODIC:
.
0
LEAK: MIN ANNUAL
L 3'r'IESEL ANN
TRI -STATE
LEAK MIN ANNUAL
Oi
tSINGLp
CATEGORY FLOAT)
ANNULAR. SPA,',
0
PERIODIC TEST TZPE
STAN:
PERIODIC TEST.TYPE
L 4:87 S TP`
STANDARD
ANNUAL TEST FAIL
TRI -� E
CATECt, S I N tXE F
ANNUAL TEST FAIL
ALARM DISH:
STP LOATH
BUMF
.
ALARM DISABLED
PERIODIC TEST FAIL
ALARM DISA:
L 5, 9!
PERIODIC TEST FAIL
TRI- STATEP;SINGLE
ALARM DISABLED
GROSS TEST FAIL
A
GAT1rGORY F
FLOAT)
ALARM DI
STP :sup
GROSS TEST `FAIL
ALARt1
r aN14 TEST kv'ERAa I Ni :
L 6:D'IESEL
TRI -S TAT STP
,DISF;BLELi
ANN TEST AVERAOING:
OFF
PER TEST AI +ERAc'I NG :
CATEGORY E 'SINGLE
ATEta.ORY
PER TEST AVERHG'I.NG:
OFF
TANK TEST NOTIFY:
STP SUMPLOAT)
TANK TEST NOTIFY:.
OFF
T'NK TST SIPHON BkE(;k:
TNK TST SIPHON BREAK:OF'F
DELIVERY.DELAIZ 5
PUMP THRESHOLD : I
DELI VFpv rnct nv
z ri)10 ra U]cnir�.cnvi.ti
�mc a^; -1m•• dar,dt7
Dcn
ID , W. rr
mma SKt -1tn•• r
-- try
cninzr.EF,@1
vt+.t7on
rrC' 77'
i^ z :y+;r.V-
r pc x -1 n..
MInt7 st - TjO <<.<C0•-
me Ff m rtI 't7b7: mx�-;
tJ?mC a rZ -- `r]
me rc7 rtci{
<<Co0 -•�
b�v�mz+ a
iri`r1*J a r—
me r-
�mco i m m moom 1`1r
m
Zmw
Ui
zmw y
Corm xt
�rQ O DD •D- U1r',�CpbD
�rG � OD
�t"O
Cxb t�s7 tr3 Z ^rlDh7t�t�77
HsT. C7 m►n tl�i!
cxD+� tom*+ r
`�+
•CD•3�r'G't?7�
U1I*9Dt7m
p
c7Dtl ttv,
mD
3>;r-
r �
m3 >7ccow
r
•-3
D D.
r
1 D x
r
7_
ITJ
IN—TANK SETUP
T 1:UNL -87
s
PRODUCT CODE
661 -396 -95$2
THERMAL COEFF
0
TANK AIA1gETER
:.000701
TANK PROFILE
c 120.
00
FULL VOL
90.0 INCH VOL
4 PTS
19951
60 INCH VOL
1795s 17956
30.0 INCH VOL
10044
DELIVERY' LIMIT
3804
FLOAT SIZE:
1999 TAFT HWY
4.0 IN.
WATER WARNING,
661 -396 -95$2
HIGH WATER LIMIT:
0
: DISf�BLED
3,Q
MAX OR LABEL
0 4 UUL:
ERFIL.L LIMIT
19951
DISABLED
90%
HIGH
1795s 17956
•
95 %`
DELIVERY' LIMIT
10953
NEEDED WRN
10%
1995
LOW PRODUCT'
LEAK ALARM LIMIT:
SUDDEN LOSS
642
99
LIMIT:
TANK TILT
.50
PROBE OFFSET
0.00 .
'
0,00
SIPHON MANIFOLDED TANKS
Tu: NONE
LINE MANIFOLDED TANKS
T #: NONE
LEAK MIN PERIODIC: 0%
0
LEAK MIN ANNUAL
' 0
PERIODIC TEST TYPE
STANDARD
ANNUAL TEST FAIL
ALARM DISABLED
PERIODIC TEST FAIL
ALARM DISABLED
'-TRUSS TEST FA 11.
ALARM DISABLED
ANN TEST AVERAGING: OFF
PER TEST AVERRGI OFF
TANK TEST NOTIFY: OFF
TNK TST SIPHON BREAK :OFF
DELIVERY DELAY 5 MIN
PUMP THRESHOLD 10.00% .
COMMUNICATIONS SETUP
PORT SETTINGS:
COMM.BOARD 1 (EDIM ?
RS -232 SECURITY
:CODE : DISABLED
COMM BOARD : 2 (RS-232)
HAUD.RATE 1200
PARITY UDD.
STOP BIT 1 STOP
DATA LENGTH: 7 DATA
RS -232 SECURITY
CODE : DISABLED
AUTO TRANSMIT SETTINGS
AUTO LEAK ALARM LIMIT
DISABLED
.AUTO HIGH WATER LIMIT
DISABLED
AUTO. OVERFILL LIMIT
DISABLED
AUTO.LQW PRODUCT
DISABLED
AUTO THEFT LIMIT
DISABLED
.AUTO DELIVERY START
DISABLED.
AUTO DELIVERY END
DISABLED
AUTO EXTERNAL INPUT ON
DISABLED
AUTO EXTERNAL INPUT OFF
DISABLED
AUTO SENSOR FUEL ALARM
DISABLED
AUTO SENSOR WATER ALARM
DISABLED
AUTO SENSOR OUT ALARM
DISABLED
RS -232 END OF MESSAGE
DISABLED
SYSTEM UN 1 Tj'_-'�
U.S. y
SYSTEH LANGUAGE r
ENGLISH
SYSTEM DATE.,'T I ME FORNihT
1 °1014 DD YYYY. HH : MM : SS x1'I
i : HEI)PG N
1999 TAFT HWY
13AKERSF 1 EL.D' CA
661 -396 -95$2
SHIFT TIME I
: DISf�BLED
SHIFT TIME 2
DISABLED
SHIFT TIME 3
DISABLED
SHIFT TIME 4
DISABLED
TANK PER TST
NEEIiED 1JRN
DISABLED
TANK ANN TST
NEEDED WRN
DISABLED
LINE RE- ENABLE METHOD
PASS L I NE TEST
LINE PER TST NEEDED WRN
DISABLED
LINE ANN TST NEEDED WRN
DISABLED
PRINT TC VOLUMES
ENABLED
TEMP COMPENSATION
VALUE {.DEG F >: 60:13
STICK HE'[GHT OFFSET
DISABLED
ULLAGE: 90%
H- PROTOCOL DATA FORMAT
HEIGHT
DAYLIGHT SAVING TIME
ENABLED
START DATE
APR WEEK I SUN
START TIME
2.00 AM
END DATE
OCT WEEK'E- SUN
END TIME
2:00 AM
RE- DIRECT LOCAL PRINTOUT
DISABLED
EURO PROTO,,',OL PREFIX
S
SYSTEI'] SECURITY
CODE : 000000
MAINTENANCE H18 TORY'
DISABLED
TANK CHART SECURIT`!
DISABLED
CUSTOM ALARMS
DISABLED
SERVICE NOTICE
DISABLED
ISO 3166 COUNTRY
CODE:
P9AS5 -'DENS I T'Y
l�
MONITOR CERT. FAILURE REPORT
SITE NAME: CHEVRON DATE • 7114111
ADDRESS: 1999 TAFT HWY TECHNICIAN: RICHARD MASON
THE FOLLOWING COMPONENTS WERE REPLACEDiREPAIRED TO COMPLETE
TESTING.
LABOR:
PARTS INSTALLED:
Ica VC e -cc k-*,
NAME: TITLE
SIGNATURE:
THE ABOVE NAMED PERSON TAKES. FULL RESPONSIBILITY OF NOTIFYING
THE APPROPRIATE PARTY TO HAVE CORRECTIVE ACTION TAKEN TO REPAIR
THE ABOVE LISTED.PROBLEMS AND N. OTIFYING RICH ENVIRONMANTAL FOR
ANY NEEDED RETESTING. THIS ALSO RELEASES RICH ENVIRONMENTAL OF
ANY FINES OR PENALTIES OCCURING. FROM NON - COMPLIANCE.
A COPY OF THIS DOCUMENT HAS BEEN LEFT ON -SITE FOR YOUR
CONVIENENCE.