HomeMy WebLinkAbout2010 FMC RESULTSAppendix VI (Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at http: / /www.waterboards.ca.-gov.) MONITORING SYSTEM CERTIFICATION For Use By All Jurisdictions Within the State of California Authority Cited., Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations This form must be used to document testing and servicing of monitoring equipment A separate certification or report must be prepared for each monitoring system control panel by the technktian who performs the work. A copy of this torn must be provided to the tank system owner/operator. The owner /operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. A. General Information Facility Name: Bakemfleld City Com Yard Bldg. No.: Site Address: 4101 Tmxtun Ave. City: Bakersfield Zip: Facility Contact Person: Contact Phone No.: Make/Madel of Monitodng System Veeder -Root TLS -350 Date of Testing /Servicing: _j21 15 f2010 B. Inventory of Equipment Tested/Certified Check the appropriate boxes to Indicatespecific equipment Insl acted /serviced: Tank ID: 87 UL Tank to: ❑ In -Tank Gauging Probe. Model: 848390 ❑ In -Tank Gauging Probe. Model: ❑ Annular Space or Vault Sensor. Model: _ 794390409 0 Annular Space or Vault Sensor. Model: ❑ Piping Sump / Trench Sensor(s). Model: 794380-208 0 Piping Sump / Trench Sensor(s). Model: 0 FIII Sump Sensor(s). Model: 0 Fill Sump Sensor(s). Model: ❑ Mechanical Una Leak Detector. Model: FXV 0 Mechanical Line Leak Detector. Model: 0 Electronic Una Leak Detector. Model: ❑ Electronic tine Leak Detector. Model: 0 Tank Overfill / High -Level Sensor. Model: ❑ Tank Overfill / High -Level Sensor. Model: 0 Other (specify equipment type and model In Section E on Pane 2). 0 Other (specify equipment type and model In Section E on Page 2). Tank ID: 91 UL Tank ID: 0 In -Tank Gauging Probe. Model: 848390 ❑ In -Tank Gauging Probe. Model: ❑ Annular Space or Vault Sensor. Model: 794390409 ❑ Annular Space or Vault Sensor. Model: ❑ Piping Sump/ Trench Sensor(s). Model: 794380.208 D Piping Sump / Trench Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: 0 Fill Sump Sensor(s). Model: 0 Mechanical Une Leak Detector. Model: FXV ❑ Mechanical Line Leek Detector. Model: ❑ Electronic Line Leak Detector. Model: 0 Electronic Line Leak Detector. Model: 0 Tank Overfill / High -Level Sensor. Model: 0 Tank Overfill / High -Level Sensor. Model: ❑ Other (specily equipment typo and model M Section E on Pane 2). ❑ Other s equipment type and model In Section E on P290 2). DlapenserlD: 1 -2 Dispenser ID: 0 Dispenser Containment Sensor(e). Model: 847990-001 0 Dispenser Containment Sensor(s). Model: ❑ Shear Valve(s). ❑ Sheer Valve(a). 0 Dispenser Containment Float(s) and Chain(s). ❑ Dispenser Containment Floats and Chain e . Dispenser ID: 7-8 Dispenser ID: ❑ Dispenser Containment Sensor(s). Model: 847990.001 ❑ Dispenser Containment Sensor(s). Model: ❑ Shear Volve(s). ❑ Shear Valve(s). 0 Dis sneer Containment Float a and Chain(s). 11 Dls sec Containment Floa a and Chain e . Dispenser ID: Dispenser to: ❑ Dispenser Containment Sensor(s). Model: 0 Dispenser Containment Sensor(s). Model: 0 ShearValve(s). ❑ ShearValve(s). ❑ Dia near Containment Front a and Chain a ❑ Dis sneer Containrrrent Floe s end Chain e . 'If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser of the facility. C. Certification - I certtfy that the equipment Identifled in this document was Inspected/serviced In accordance with the manufacturers' guidelines. Attached to this Certification Is Information (e.g. manufacturers' checklists) necessary to verity that this Information is correct and a Plot Plan showing the layout of monitoring equipment For any equipment capable of generating such reports, I have also attached a copy of the report; (checkoff that apply): X System set -up X Alarm history report Technician Name (print): Bruce W. Hinslev Signature: Certification No.: A25212 License. No.: 92173M Testing Company Name: Cal - Valley Eouipment Phone No.:(881) 327 -9341 Testing Company Address: 3500 Gilmore Ave. Bakersfield. Co. 93308 Date of Testing/Servicing: 12 / 15 / 2010 Monitoring System Certification Page 1 of 4 12/07 2/21/07 D. Results of Test]ng/Servlcing Software Version Installed: 123.02 Comolete the followlno checklist: X Yes ❑ No' Is the audible alarm operational? X Yes ❑ No' Is the visual alarm operational? X Yes ❑ No' Were all sensors visually Inspected, functionally tested, and confirmed operational? X Yes ❑ No' Were all sensors Installed at lowest point of secondary containment and positioned so that other equipment will not interfere with their proper o ration? ❑ Yes ❑ No' If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) operational? X N/A Yes X No' For pressurized piping systems, does the turbine automatically, shut down if the piping secondary containment monitoring system ❑ NIA detects a leek falls to operate, or Is electrically disconnected? If yes: which sensors initiate positive shut-down? (Check all that apply) X Sump/Trench Sensors; Dispenser Containment Sensors. Did you confirm positive shut -down due to leaks Ia sensor failureldisconnection? XYes• ❑ No. ❑ Yes ❑ No' For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e, no mechanical overfill prevention X N/A valve Is Installed), Is the overfill warning alarm visible and audible at the tank fill point(s) and operating properly? If so, at what percent of tank capacity does the alarm tri er? % ❑ Yes' X No Was any monitoring equipment replaced? If yea, Identify specific sensors, probes, or other equipment replaced and list the manufacturer name and model for all replacement parts in Section E below. ❑ Yes' X No Was liquid found inside any secondary containment systems designed as dry systems? (Check a// that apply) ❑ Product; ❑ Water. If es, describe causes in Section E below. X Yea ❑ No' Was monitoring system set-up reviewed to ensure proper settings? Attach set up reports, if applicable X Yea ❑ No' Is all monitoring equipment operational per manufacturers specifications? • In Section E below, describe how and when these deficiencies were or will be corrected. Comments: Performed Product line testing. Monitoring System Certification Page 2 of 4 12107 2/21/07 F. In -Tank Gauging / SIR Equipment: X Check this box if tank gauging is used only for inventory control. ❑ Check this box if no tank gauging or SIR equipment is Installed. This section must be completed If In -tank gauging equipment is used to perform leak detection monitoring. Loom fete me r000wm cnecmim: ❑ No' Yes ❑ No' Has all Input wiring been inspected for proper entry and termination, Including testing for ground faults? Yes ❑ No' Were all tank gauging probes visually inspected for damage and residue buildup? Yes ❑ No' Was accuracy of system product level readings tested? Yes D No' Was accuracy of system water level readings tested? Yee Cl No' Were all probes reinstalled properly? Yes ❑ No' Were all items on the equipment manufacturer's maintenance checklist completed? In the aecuon n, oelow, as cnae now ana wren mesa aenciencles were or Win ae corrected. II G. Line Leak Detectors (LLD): ❑ Check this box If LLDs are not Installed. 1 !`w.....In�n 11,e lnll.�wlnn whn..Lllu�• • Yes ❑ No' For equipment start-up or annual equipment certification, was a leak simulated to verity LLD performance? (Check all ❑ WA that apply) Simulated leak rate: X 3 g.p.h.; 0 0.1 g.p.h ; ❑ 02 g.p.h. • Yes ❑ No' Were an LLDs confirmed operational and accurate within regulatory requirements? • Yes ❑ No' Was the testing apparatus properly calibrated? • Yes ❑ No* For mechanical LLDs, does the LLD restrict product flow if it detects a leak? ❑ WA ❑ Yes 0 No' For electronic LLDs, does the turbine automatically shut off if the LLD detects a leak? X WA ❑ Yes ❑ No' For electronic LLDS, does the turbine automatically shut off if any portlon of the monitoring system is disabled or X WA disconnected? ❑ Yes 0 No' For electronic LLDs, does the turbine automatically shut off if any portion of tt7e monitoring system malfunctions or X WA fails a test? ❑ Yes ❑ No' For electronic LLDs, have all accessible wiring connections been visually Inspected? X WA X Yes ❑ No' Were all items on the equipment manufacturer's maintenance checklist completed? In the Section H, below, describe how and when these deficiencies were or will be corrected. H. Comments: Monitoring System Certification Page 3 of 4 12107 3 2/21/07 Monitoring System Certification UST Monitoring Site Plan She Address: _ 4101 Truxtun Ave. Bakersfield. Ca. Date map was drawn: _j2_1 ;_/2010 . Instructions If you already have a diagram that shows all required information, you may include it, rather than thla page, with your Monitoring System Certification. On your site plan, show the general layout of tanks and piping. Clearly Identify locations of the following equipment, it installed: monitoring system control panels; sensors monitoring tank annular spaces, sumps, dispenser pans, spill containers, or other secondary containment areas; mechanical or electronic line leak detectors; and in -tank liquid level probes (if used for leak detection). In the space provided, note the date this Site Plan was prepared. Monitoring System Certification Page 4 of 4 12107 4 2/21/07 CAL- VALLEY EQUIPMENT 3500 Gilmore Avenue AES PLT -100R Bakersfield, CA 93308 Ph#661- 327 -9341 Fax#661- 325 -2529 NAME: Bakersfield City Corp. Yard LINE #1: Diesel TECHNICIAN: Bruce W. Hinsle ADDRESS: 4101 Truxtun Ave. LINE #2: 87 UL LICENSE #: 90 -1069 CITY/ ST.: Bakersfield, Ca. LINE #3: -0.021 TEST DATE: 12/15/2010 -HE CONVERSION CONSTANT IS FOUND BY: (60 MIN /HR) / (37901MIL/GAL) = 0.0158311 (MIN/HOUR (GAL/MIN) Wide the volume differential by the test time (15 minutes) and multiply by 0. 0158311, which will convert the volume differential from milliliters per ninute to gallons per hour. The conversion constant causes the millimeters and minutes to cancel out PRODUCT TIME. PSI START VOL ml END VOL ml TEST VOL DIFF. ml GPH GAIN/LOSS (ml) PASS FAIL Diesel 10:10 50 222 201 21 -0.021 X ° 10:25 50 201 181 21 -0.020 x COMMENTS: PRODUCT TIME PSI START VOL ml END VOL (mo TEST VOL DIFF. ml GPH GAIN/LOSS (ml) PASS FAIL 87 UL 11:40 50 200 177 23 -0.023 x ° 11:55 50 177 155 22 -0.022 x COMMENTS: PRODUCT TIME PSI START VOL ml END VOL ml TEST VOL DIFF. ml GPH GAIN/LOSS (ml) PASS FAIL COMMENTS: I declare under penalty of perjury that I am a licensed tank tester in the State of California and I X that the information in this report is true and correct to the best of my knowledge. w CVE Cal- Valley Equipment 3500 Gilmore Ave. Bakersfield CA 93308 661 - 327 -9341 FAX# 661 -325 -2529 VAPORLESS MAr1UFACrURING, INC. LDT -890 Leak Detector Temt Record Contractor. Cal-Valley Equipment Customer: Bakersfield City Corp Yard Date: 12/15/2010 Location: 4101 Ttvxtun Ave. Bakersfield, Ca. Product: Diesel Technician: Bruce W. Hinsle I Manufacturer: F E Petro I Model No.: I Serial No.: Leak Detector identification Manufacturer: Red'acket Description: Dia Piston-type: PLD Tamper -proof seal installed: Other Style Leak Detector: Notes: Leak Detector in Submersible Pumn Test at Dianenser Operating Pump Pressure (psi): 28 (para. 15 Gallons per hour rate: 3.0 .22 Line pressure with pump shut off (psi): 20 23 Bleed -back Test with pump off (ml): 60 (para. 26 Step-through Step-through time to full flow (secs): 3 (para. 30 Leak detector stays in leak search position (Yes/No): Yes 42 Leak Detector Test Pass / Fail Notes: Pass _ *Complete thermal expansion test before failing leak detector CVE Cal- Valley Equipment 3500 Gilmore Ave. Bakersfield CA 93308 661 - 327 -9341 FAX# 661 - 325 -2529 VAPORLESS MANUFACTURING, INC. LDT -890 Leak Detector Test Record Contractor: Cal-Valley Equipment Customer: Bakersfield City Corp Yard . Date: 12/15/2010 Location: 4101 Truxtun Ave. Bakersfield Ca. Product: 87 UL Technician: Bruce W. Hinsle Submersible Pumn Identification E Petro Serial No.: I Notes: I Leak Detector Identification Manufacturer: Red'acket Description: Diaphragm-type: Piston-type: PLD Tamper -proof seal installed: Other Style Leak Detector: Notes: Leak Detector in Submersible Pump Test at Dispenser Operating Pressure (psi): 28 ara 15 Gallons per hour rate: 3.0 22 Line pressure with pump shut off (psi): 25 23 Bleed -back Test with pump off (ml): 55 26 St through time to full flow (secs): 3 30 Leak detector stays in leak search position (Yes/No): Yes 42 Leak Detector Test Pass / Fail Notes: Pass *Complete Thermal expansion test before failing leak detector «.. �,. _ ....- _.. -__---- - _... ----------- . . - - .. - ......_ x x x x END x ** x VERSIOtV 123.02 ALARM HISTORY REPORT SOFTWARE# 346123 -100 —C CREATED — 02.11.25.15.17 - - -- IN —TANK ALARM - - - -- NO SOFTWARE MODULE T 21DIESEL —NO.2 SYSTEM FEATURES: PERIODIC IN —TANK TESTS y ANNUAL IN —TANK TESTS DELIVERY NEEDED 3 DEC 14, 2010 2:43 PM DEC 3, 2010 1:01 PM NOV 23, 2010 6:32 AM r I ALARM HISTORY REPORT II -- i I�lI -- SENSOR ALARM --- -- d. L 3:DIESEL STP d ddd STP SUMP A FUEL ALARM ALARM HISTORY REPORT ` DEC 15, 2010 i0:00 AM l -- SYSTEM ALARM - - - -- '•"FUEL ALARM DEC 18, 2009 9:37 AM R PAPER OUT NOV 19, 2010 8:00 AM x x x x x END x * x x * -FUEL ALARM PR [ tVTER ERROR NOV 19, 2010 8:00 AM 1; DEC 18, 2009 6:24 AM . BATTERY IS OFF JAN 1, 1996 8:00 AM I i ALARM HISTORY REPORT x x x x x END x x x x x - - - -- SENSOR ALARM - - - -- x x* x x END x x x x x L 1:UNLEADED STP STP SUMP I. FUEL ALARM DEC 15, 2010 10:00 AM FUEL ALARM I li !l DEC 16, 2009 9:37 AM FUEL ALARM DEC 18, 2009 8:19 AM ALARM HISTORY REPORT — SENSOR ALARM - -- C ALARM HISTORY REPORT 4:DIESEL ANNULAR ` fL ANNULAR SPACE - - -- IN —TANK ALARM - -- -- FUEL ALARM I� DEC 15, 2010 10:07 AM T 1:UNLEADED t' j I FUEL ALARM HIGH WATER ALARM DEC 18. 2009 9:37 AM AUG 24, 2005 11:54 AM fxxxxENDxxxxx FUEL ALARM OVERFILL ALARM DEC 18, 2009 8:28 AM JAN 5, 2004 8:14 AM NOV 7, 2003 11 :42 AM HIGH PRODUCT ALARM JAN S. 2004 8:14 AM NOV 7, 2003 11:39 AM i PRO13E OUT DEC 22, 2003 11:18 AM HIGH WATER WARNING ALARM HISTORY REPORT x x x x x END x x x x x j AUG 24, 2005 11:54 AM � ----- SENSOR ALARM -- - -- 4,. - L 2:UNLEADED ANNULAR DELIVERY NEEDED ANNULAR SPACE DEC 9, 2010 6:24 AM FUEL ALARM NOV 24, 2010 9:40 AM DEC 15, 2010 10:05 AM NOV 10, 2010 2:01 PM FUEL ALARM DEC 18, 2009 9:38 AM FUEL ALARM DEC 18. 2009 8 :22 AM . .. PERIODIC TEST TYPE STANDARD ANNUAL TEST FAIL i ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED I GROSS TEST FAIL fff ALARM DISABLED ANN TEST AVERAGING: OFF PER TEST AVERAGING: OFF TANK TEST NOTIFY: OFF TNK TST SIPHON BREAK:OFF I DELIVERY DELAY 3 MIN PUMP THRESHOLD 10.00X LEAK TEST METHOD TEST ON DATE : ALL TANK JAN 1, 1996 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION 2 HOURS TST EARLY STOP:DISAELED LEAK TEST REPORT FORMAT NORMAL . l t 1 OUTPUT RELAY SETUP f R !:UNLEADED —STP TYPE: STANDARD NORMALLY CLOSED IN —TANK ALARMS T !:HIGH WATER ALARM T !:LOW PRODUCT ALARM LIQUID SENSOR ALMS 1 L !:FUEL ALARM L !:SENSOR OUT ALARM L 2:SENSOR OUT ALARM L !:SHORT ALARM L 2:SHORT ALARM R 2.:DIESEL STP TYPE: STANDARD 1ORMALLY CLOSED IN —TANK ALARMS T 2.:HIGH WATER ALARM T 2:LOW PRODUCT ALARM LIQUID SENSOR ALMS L 3 :FUEL ALARM L 3:SENSOR OUT ALARM L 4:SENSOR OUT ALARM L 3:214ORT ALARM L 4:SHORT ALARM R 3:REMOTE BEACON TYPE: STANDARD NORMALLY CLOSED IN —TANK ALARMS ALL:LOW PRODUCT ALARM LIQUID SENSOR ALMS ALL:FUEL ALARM ALL:SENSOR OUT ALARM ALL:SHORT ALARM LIQUID SENSOR SETUP L 1 :UNLEADED STP TRI —STATE (SINGLE FLOAT) CATEGORY : STP SUMP L 2:UNLPADED ANNULAR TRI —STATE (SINGLE FLOAT) CATEGORY : ANNULAR SPACE RECONCILIATION SETUP I L 3:DIESEL PERIODIC TEST TYPE AUTOMATIC DAILY CLOSING TRI —STATE QUICK :' TINE: 2:00 AM ANNUAL TEST FAIL STP SUMP ALARM DISABLED j PERIODIC TEST FAIL _ ALARM DISABLED L 4:DIES£L GROSS TEST FAIL TRI —STATE ALARM DISABLED TEMP COMPENSATION STANDARD ANN TEST AVERAGING: OFF ;. PER TEST AVERAGING: OFF TANK TEST NOTIFY: OFF .: c BUS SLOT FUEL METER TANK TNK TST SIPHON SREAK:OFF .f 1s .DELIVERY DELAY 3 MIN i PUMP THRESHOLD 10.00% J 1 T 2:DIESEL —NO.2 PRODUCT CODE 2 THERMAL COEFF :.000470 TANK DIAMETER 119.36 TANK PROFILE 4 PTS FULL VOL 14783 89.5 INCH VOL 12023 59.7 INCH VOL 7400 , 29.8 INCH VOL 2750 FLOAT SIZE: 4.0 IN. { WATER WARNING 2.0 HIGH WATER LIMIT: 4.0 MAX OR LABEL VOL: 14783 ' OVERFILL LIMIT 990Ac 14635 HIGH PRODUCT 98K JI II 14487 ; DELIVERY LIMIT 40% pt 5913 s LOW PRODUCT 300 `I LEAK ALARM LIMIT: 99 d SUDDEN LOSS LIMIT: 99 ; TANK TILT — 0.25 .! PROBE OFFSET 0.00 SIPHON MANIFOLDED TANKS TO: NONE LINE MANIFOLDED TANKS TO: NONE LEAK MIN PERIODIC: 0)t LEAK MIN ANNUAL : ox }: 0 PERIODIC TEST TYPE STANDARD ANNUAL TEST FAIL i ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED I GROSS TEST FAIL fff ALARM DISABLED ANN TEST AVERAGING: OFF PER TEST AVERAGING: OFF TANK TEST NOTIFY: OFF TNK TST SIPHON BREAK:OFF I DELIVERY DELAY 3 MIN PUMP THRESHOLD 10.00X LEAK TEST METHOD TEST ON DATE : ALL TANK JAN 1, 1996 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION 2 HOURS TST EARLY STOP:DISAELED LEAK TEST REPORT FORMAT NORMAL . l t 1 OUTPUT RELAY SETUP f R !:UNLEADED —STP TYPE: STANDARD NORMALLY CLOSED IN —TANK ALARMS T !:HIGH WATER ALARM T !:LOW PRODUCT ALARM LIQUID SENSOR ALMS 1 L !:FUEL ALARM L !:SENSOR OUT ALARM L 2:SENSOR OUT ALARM L !:SHORT ALARM L 2:SHORT ALARM R 2.:DIESEL STP TYPE: STANDARD 1ORMALLY CLOSED IN —TANK ALARMS T 2.:HIGH WATER ALARM T 2:LOW PRODUCT ALARM LIQUID SENSOR ALMS L 3 :FUEL ALARM L 3:SENSOR OUT ALARM L 4:SENSOR OUT ALARM L 3:214ORT ALARM L 4:SHORT ALARM R 3:REMOTE BEACON TYPE: STANDARD NORMALLY CLOSED IN —TANK ALARMS ALL:LOW PRODUCT ALARM LIQUID SENSOR ALMS ALL:FUEL ALARM ALL:SENSOR OUT ALARM ALL:SHORT ALARM LIQUID SENSOR SETUP L 1 :UNLEADED STP TRI —STATE (SINGLE FLOAT) CATEGORY : STP SUMP L 2:UNLPADED ANNULAR TRI —STATE (SINGLE FLOAT) CATEGORY : ANNULAR SPACE RECONCILIATION SETUP I L 3:DIESEL STP AUTOMATIC DAILY CLOSING TRI —STATE (SINGLE FLOAT) :' TINE: 2:00 AM CATEGORY STP SUMP 1 PERIODIC RECONCILIATION MODE: MONTHLY . L 4:DIES£L ANNULAR TRI —STATE (SINGLE FLOAT) TEMP COMPENSATION STANDARD CATEGORY ANNULAR SPACE.{ c BUS SLOT FUEL METER TANK i ;Y. — — — — — — — — — — — — TANK MAP EMPTY , 1 k SYSTEM SETUP DEC 15. 2010 12:41 PM SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH :MM:SS xM CITY CORP. YARD 4101 TRUXTON AVE. SAKERSERFID CA.93309 661- 326 -3795 SHIFT TIME I DISABLED SHIFT TIME 2 : DISABLED SHIFT TIME 3 DISABLED SHIFT TIME 4 DISABLED TANK PER TST NEEDED WRN DISABLED TANK ANN TST NEEDED WRN DISABLED LINE RE- ENABLE METHOD PASS LINE TEST LINE PER TST NEEDED WRN DISABLED LINE ANN TST NEEDED URN DISABLED PRINT TC VOLUMES ENABLED TEMP COMPENSATION VALUE (DEC F ): 60.0 STICK HEIGHT OFFSET DISABLED DAYLIGHT SAVING TIME i ENABLED START DATE APR WEEK 1 SUN �1 START TIME +I 2:00 AM i END DATE OCT WEEK 6 SUN END TIME 2:00 AM ¢ (.i CUSTOM ALARM LABELS DISABLED COMMUNICATIONS SETUP PORT SETTINGS: NONE FOUND.:- . RS -232 END OF MESSAGE DISABLED 1N -TANK SETUP T 1:UNLEADED PRODUCT CODE 1 THERMAL COEFF :.000700 TANK DIAMETER 119.38 TANK PROFILE 4 PTS FULL VOL 14783 89.5 INCH VOL 12023 59.7 INCH VOL 7400 29.8 INCH VOL 2750 FLOAT SIZE: 4.0 IN, j WATER WARNING 2.0 HIGH WATER LIMIT: 4.0 MAX OR LABEL VOL: 14783 OVERFILL LIMIT 99% 14635 HIGH PRODUCT 9B% 14487 DELIVERY LIMIT 40% 5913.. LOW PRODUCT 300 :