HomeMy WebLinkAbout2011 RESULTSp2ss MONITORING SYSTEM CERTIFICATION For Use By All Jurisdictions Within the Stale of California Authority Cited: Chapter. 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations This form must be used to document testing and servicing of monitoring equipment. A separate certification or rep2rt must be prepared for_Mch monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner /operator. The owner /operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. A. General Information Facility Name: HOWARDS MINI MART Site Address: 4201 BELLE TERRACE Facility Contact Person: Make/Model of Monitoring System: TLS-360 ERNIE MEDINA ON -SITE Date of Testing/Servicing: 11 -10 -11 B. Inventory of Equipment Tested /Certified Check the approRnate boxes to indicatespecific equipment inspected/serviced: Bldg. No.: City: BAKERSFIELD Zip: 93309 Contact Phone No.: ( ) Tank ID: UNL87 Tank ID: PREM91 SPLIT DIESEL ® In -Tank Gauging Probe, Model: MAGI ® In -Tank Gauging Probe. Model: MAGI ® Annular Space or Vault Sensor. Model: 420 ® Annular Space or Vault Sensor. Model: 420 9 Piping Sump / Trench Sensor(s). Model: 208 ® Piping Sump / Trench Sensor(s). Model: 208 ® Fill Sump Sensor(s). Model: 208 ® Fill Sump Sensor(s). Model: 208 ® Mechanical Line Leak Detector. Model: FX1V ® Mechanical Line Leak Detector. Model: FX1V ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: ® Tank Overfill / High -Level Sensor. Model: MAGI ® Tank Overfill / High -Level Sensor. Model: MAGI ❑ Other (specify equipment type and model in Section E on Page 2). ❑ Other (specify equipment type and model in Section E on Page 2). Tank ID: DIESEL SPLIT PREM91 Tank ID: ® In -Tank Gauging Probe. Model: MAGI ❑ In -Tank Gauging Probe. Model: ® Annular Space or Vault Sensor. Model: 420 ❑ Annular Space or Vault Sensor. Model: ® Piping Sump /Trench Sensor(s). Model: 208 ❑ Piping Sump / Trench Sensor(s). Model: ® Fill Sump Sensor(s). Model: 208 ❑ Fill Sump Sensor(s). Model: ® Mechanical Line Leak Detector. Model: FXIDV ❑ Mechanical Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: ® Tank Overfill / High -Level Sensor. Model: MAGI ❑ Tank Overfill / High -Level Sensor. Model: ❑ Other (specify equipment type and model in Section E on Page 2). ❑ Other (specify equipment type and model in Section E on Page 2). Dispenser ID: 1 -2 Dispenser 1D: 3-4 ® Dispenser Containment Sensor(s). Model: 351 ® Dispenser Containment Sensor(s). Model: 351 ® Shear Valve(s). ® Shear Valve(s). ❑ Dispenser Containment Float(s) and Chain(s). ❑ Dispenser Containment Float(s) and Chain(s). Dispenser ID: 5-6 Dispenser ID: 7-8 ® Dispenser Containment Sensor(s). Model: 351 ® Dispenser Containment Sensor(s). Model: 351 ® Shear Valve(s). ® Shear Valve(s). ❑ Dispenser Containment Float(s) and Chain(s). ❑ Dispenser Containment Float(s) and Chain(s). Dispenser ID: Dispenser ID: ❑ Dispenser Containment Sensor(s). Model: ❑ Dispenser Containment Sensor(s). Model: ❑ Shear Valve(s). ❑ Shear Valve(s). ❑ Dispenser Containment Float(s) and Chain(s). ❑ Dispenser Containment Float(s) and Chain(s). *If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of4enerating such reports, l have also attached a copy of the report; (check all that apply): ® System set -up ® Alarm h' report Technician Name (print): RICH PHILLIPS Signature: Certification No.: A2908411035169 -UT License. No.: C611 D40 809850 Testing Company Name: Rich Environmental Phone No.: (661) 392 -8687 Testing Company Address: 5643 BROOKS CT. BAKERSFIELD, CA 93308 Date of Testing/Servicing: 11/1012011 Page 1 of 4 UN-036 — 1/4 www.unidocs.org Rev. 01/17/08 Monitoring System Certification D. Results of Testing/Servicing Software Version Installed: 328.03 the following; checklist: ® Yes ❑ No* Is the audible alarm operational? M Yes ❑ No* is the visual alarm operational? +4 Un r. ® Yes ❑ No* Were all sensors visually inspected, functionally tested, and confirmed operational? ® Yes ❑ No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere with their proper operation? ❑ Yes ❑ No* If alarms are relayed to a remote monitoring station, is all communications equipment (e.g., modem) ® N/A operational? • Yes ❑ No* For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment ❑ N/A monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate positive shut -down? (Check all that apply) ® Sump/Trench Sensors; ❑ Dispenser Containment Sensors. Did you confirm positive shut -down due to leaks and sensor failure /disconnection? ® Yes; [I No. • Yes ❑ No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e., no ❑ N/A mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank fill point(s) and operating properly? If so, at what percent of tank capacity does the alarm trigger? 90% ❑ Yes* ® No Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced and list the manufacturer name and model for all replacement parts in Section E, below. ❑ Yes* ® No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) ❑ Product; ❑ Water. If yes, describe causes in Section E, below. ® Yes ❑ No* Was monitoring system set -up reviewed to ensure proper settings? Attach set up reports, if applicable ® Yes ❑ No* I Is all monitoring equipment operational per manufacturer's specifications? * In Section E below, describe how and when these deficiencies were or will be corrected. E. Comments: Page 2 of 4 UN-036 — 2/4 www.unidoes.org Rev. 01/17/08 Monitoring System Certification q4 `9ft F. In -Tank Gauging / SIR Equipment: ® Check this box if tank gauging is used only for inventory control. ❑ Check this box if no tank gauging or SIR equipment is installed. This Section must be completed if in -tank gauging equipment is used to perform leak detection monitoring. Complete the following checklist: ❑ Yes ❑ No* Has all input wiring been inspected for proper entry and termination, including testing for ground faults? ❑ Yes ❑ No* Were all tank gauging probes visually inspected for damage and residue buildup? ❑ Yes ❑ No* Was accuracy of system product level readings tested? ❑ Yes ❑ No* Was accuracy of system water level readings tested? ❑ Yes ❑ No* Were all probes reinstalled properly? ❑ Yes ❑ No* Were all items on the equipment manufacturer's maintenance checklist completed? * In Section H, below, describe how and when these deficiencies were or will be corrected G. Line Leak Detectors (LLD): Comnlete the following! checklist: ❑ Check this box if LLDs are not installed. ® Yes ❑ No* ❑ N/A For equipment start-up or annual equipment certification, was a leak simulated to verify LLD performance? (Check all that apply) Simulated leak rate: ® 3 g.p.h.; [10.1 g.p.h ; [10.2 g.p.h. ® Yes ❑ No* Were all LLDs confirmed operational and accurate within regulatory requirements? ® Yes ❑ No* Was the testing apparatus properly calibrated? ® Yes ❑ No* ❑ N/A For mechanical LLDs, does the LLD restrict product flow if it detects a leak? ❑ Yes ❑ No* ® N/A For electronic LLDs, does the turbine automatically shut off if the LLD detects a leak? ❑ Yes ❑ No* ® N/A For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? ❑ Yes ❑ No* ® N/A For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a test? ❑ Yes ❑ No* ® N/A For electronic LLDs, have all accessible wiring connections been visually inspected? ® Yes ❑ No* Were all items on the equipment manufacturer's maintenance checklist completed? * In Section H. below. describe how and when these deficiencies were or will he corrected. H. Comments: UN-036 — 3/4 Page 3 of 4 www.unidocs.org Rev. D1117/08 modito* .sygmc.atfimfi«, U &T Mon7tcri S if, e'Plain F . -F q -N� ... - .. r . - I - w •.�L+ r� �v'- r'� .J r . .r .. r • . r • r . . - - f - . - - - - • - r . • r • r r • • - - - - r .• '. w . ... r - - - - w • • w . . . . r • . . . . w • • • - . - - ! • - . r . . - r . . . - r - w r .. r. . . - I r . - ! . r • • r - . . . . . . . . ... . . . r r . . - . . . . r 0 • I . •� . . ... . . . - - . . r . . . . . . . r . . . . . . .. w - . _ r r . w . . ./� . . . . . . • . - r . - - - - . - • - - - - - - r - - r - - - - - - • . r . • • . r • . r •.. r • . . r . r r . . . ... ' �`. w r . . • r r r r . r = e� r . r r .� - -� - - r r -- w • . . • .!. . - .. w . w w r r r . r. r r r . . . . r . • - • I .. . . - J. w• . .: r. r . . r . .. ! . r . w . . r . .. . . . . . . r r .- - ! r • • . r r - - - .- - .. ..- • - • r . • �. r • . r . . . r. . r r r . r . . .. w r . - . . . . w r . . • . . . - w w. r . r . •. • • . . . . . . . . • . r . . r .. . . . . . . . . I . . . ...... - . . . . . . . . . . r r . . . - w - . • . • . r - . ! . . .. . . . . . . i . . . . - . . . . - - . r.... r . . - .. . - • r .r . r -. . • • .. . . . . - - . - i w .. . . r r . .. . . . .i _ � r If you ab datwtoea;:aud was prepared: . 'sue `�nctfoua a ciragram Thai sb al] i^e9iiired womsticn, yan.may incltzae. it, rather than this pale, with yoar ►.0 icaaoa Ch youi biu u' dwix, ,g�u;�: �# sa*;; i ofd ana P P � �3► owib� egmMim v j"f instaT�iad: rionitori�g.aystbt cut --sr seDS&S ritoxiug tank aaavlar Tom;�.m Ririe, 3'tsmtn�,izia�a;t:weas; rmecbanicai.or.ewcfronic.i"me team kTl-. Im4pr6lese(zf d for teak tl�t oa). is tIse V= _provided►•nof the date this Sita Plan Moo RICH ENMIRONMENTAL 5643 BROOKS CT. BAKERSFIELD, CA. 93308 OFFICE (661)392 -8687 FAX (661)392 -0621 PRODUCT LINE LEAK DETECTOR TEST WORK SHEET W /0 #: FACILITY NAME: HOWARDS MINI MART FACILITY ADDRESS: 4201 BELLE TERRACE BAKERSFIELD, CA PRODUCT LINE TYPE: PRESSURE PRODUCT LEAK DETECTOR TYPE TEST TRIP PASS BELOW P.S.I. OR SERIAL NUMBER 3 G.P.H. FAIL UNL87 LID TYPE: MECHANICAL PASS YES 11 SERIAL # RED JACKET PREM91 L/D TYPE: MECHANICAL PASS YES 10 SERIAL # RED JACKET DIESEL L/D TYPE: MECHANICAL PASS YES 9 SERIAL # RED JACKET LID TYPE YES PASS SERIAL # NO FAIL I CERTIFY THE ABOVE TESTS WERE CONDUCTED ON THIS DATE ACCORDING TO RED JACKET PUMPS FIELD TEST APPARATUS TESTING PROCEDURE AND LIMITATIONS. THE MECHANICAL LEAK DETECTOR TEST PASS I FAIL IS DETERMINED BY USING A LOW FLOW THRESHOLD TRIP RATE OF 3 GALLONS PER HOUR OR LESS AT 10 P.S.I. I ACKNOWLEDGE THAT ALL DATA COLLECTED IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE. TECHNICIAN: RICH PHILLEA SIGNATURE: DATE: 11 -10 -11 q�M SWRCB, January 2006 Spill Bucket Testing Report Form This form is intended for use by contractors performing annual testing of UST spill containment structures. The completed form and printouts from tests (f applicable), should be provided to the facility owner /operator for submittal to the local regulatory agency. 1. FACILITY INFORMATION Facility Name: HOWARDS MINI MART Date of Testing: 11 -10 -11 Facility Address: 4201 BELLE TERRACE BAKERSFIELD, CA Facility Contact: Phone: Date Local Agency Was Notified of Testing: Name of Local Agency Inspector (rf present during testing): ERNIE MEDINA 2. TESTING CONTRACTOR INFORMATION Company Name: RICH ENVIRONMENTAL Technician Conducting Test: RICH PHILLIPS Credentials': ❑ CSLB Contractor X ICC Service Tech. ❑ SWRCB Tank Tester ❑ Other (Spec) License Number(s): 1035169 -UT 3. SPILL BUCKET TESTING INFORMATION Test Method Used: X Hydrostatic ❑ Vacuum ❑ Other Test Equipment Used: VISUAL Equipment Resolution: 0.00 Identify Spill Bucket (By Tank Number, Stored Product, etc. ) 1 UNL87 2 PREM91 3 DIESEL 4 Bucket Installation Type: ❑ Direct Bury X Contained in Sump ❑ Direct Bury X Contained in Sump ❑ Direct Bury X Contained in Sump ❑ Direct Bury ❑ Contained in Sum Bucket Diameter: 12" 12" 12" Bucket Depth: 16" 16" 16" Wait time between applying vacuum/water and start of test: 30 MIN 30 MIN 30 MIN Test Start Time (T[): 9:00 9:00 9:00 Initial Reading (R,): 14" 14" 14" Test End Time (TF): 10:00 10:00 10:00 Final Reading (RF): 14" 14" 14" Test Duration (TF — Tj): 1 -HOUR 1 -HOUR 1 -14OUR Change in Reading (RF -Rj): 0" 0" 0" Pass /Fail Threshold or Criteria: +/-0.00 +/-0.00 +/-0.00 Test Result: X Pass ❑ Fail X Pass ❑ Fail X Pass ❑ Fail ❑ Pass ❑ Fail Comments — (include information on repairs made prior to testing, and recommended follow -up for failed tests) CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING I hereby certify that all the information c talned in this report is true, accurate, and in full compliance with legal requirements. Technician's Signature: Date: 11 -10 -11 ' State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements may be more stringent. I OFTWARE Klry i 5 i J"I y LY.LL ER IOti V8.03 :OFTWARE# 346328 °100-1) SYSTEM SETUP _ _ _ _ _ _ _ - -^ COMMUNICATIONS SETUP TREATED - 08.06.06.17.21 _ NOV 10, 2011 8: 41 AM - - - - - - - - - - - 3- MODULE# 330160 -004 -a ;.STEM FEATURES: PORT SETTINGS: PERIODIC IN -TANK TESTS SYSTEM UNITS ANNUAL I iV -TANK TESTS U.S. BOARD : 1 ( ED 11 °1 ) ISD SYSTEM LANGUAGE RS -232 SECURITY ENGLISH CODE : DISABLED SYSTEM DATE /TIME FORMAT MON DD YYYY HH : MM : SS xl °1 COMM BOARD 5 (RS -485} BAUD RATE 2400 HOWARDS MINI HART PARITY EVEN 4201 BELLE TERRACE STOP BIT 1 STOP BAKERSFIELD.CA 93309 DATA LENGTH: 7 DATA 661 - 397 -7600 RS-232 SECURITY CODE : DISABLED SHIFT TIME I DISABLED SHIFT TIME 2 DISABLED COMM BOARD 6 (RS -232) SHIFT TIME 3 DISABLED BAUD RATE 1200 SHIFT TIME 4 DISABLED PARITY ODD STOP HIT 1 STOP TANK PER TST NEEDED WRN DATA LENGTH: 7 DATA DISABLED RS -232 SECURITY TANK. ANN TST NEEDED WR1••1 CODE : DISABLED DISABLED LINE RE-ENABLE METHOD AUTO TRANSMIT SETTINGS: PASS LINE TEST AUTO LEAK ALARM LIMIT LINE PER TST NEEDED WRN DISABLED DISABLED AUTO HIGH WATER LIMIT LINE ANN TST NEEDED WRN DISABLED DISABLED AUTO OVERFILL LIMIT DISABLED PRINT TC VOLUMES AUTO LOW PRODUCT ENABLED DISABLED AUTO THEFT LIMIT TEMP COMPENSATION DISABLED VALUE (DEC F ): 60.0 AUTO DELIVERY START STICK HEIGHT OFFSET DISABLED DISABLED AUTO DELIVERY END ULLAGE: 90% DISABLED AUTO EXTERNAL INPUT ON H- PROTOCOL DATA FORMAT DISABLED HEIGHT AUTO EXTERNAL INPUT OFF DAYLIGHT SAVING TIME DISABLED DISABLED AUTO SENSOR FUEL ALARM RE- DIRECT LOCAL PRINTOUT DISABLED DISABLED AUTO SENSOR WATER ALARM DISABLED EURO PROTOCOL PREFIX AUTO SENSOR OUT ALARM S DISABLED SYSTEM SECURITY CODE : 000000 MAINTENANCE HISTORY DISABLED RS -232 END OF MESSAGE DISABLED TANK CHART SECURITY DISABLED CUSTOM ALARMS DISABLED SERVICE NOTICE DISABLED MASS /DENSITY DISABLED 'A 44199 f N--TANK SETUP ^ T 1:REG.ULAR PRODUCT LODE I THERMAL GOEFF :•000700 TANK DIAMETER 113.75 TANK PROFILE 1 PT FULL VOL 15023 FLOAT SIZE: 4.0 IN. WATER WARNING 2,0 HIGH WATER LIMIT: 3:0 MAX OR LABEL VOL: 15023 OVERFILL LIMIT 90% 9066 13520 HIGH PRODUCT 95% 10% 1007 14271 DELIVERY LIMIT 10% 1502 LOW PRODUCT 500 LEAK ALARM LIMIT: 99 SUDDEN LOSS LIMIT: 50 TANK TILT 0.00 PROBE OFFSET 0.00 SIPHON MANIFOLDED TANKS T#: NONE LINE MANIFOLDED TANKS T #: NONE LEAK MIN PERIODIC: 10 %s 1502 LEAS: MIN ANNUAL 10% 1502 PERIODIC PEST TYPE STANDARD ANNUAL TEST FAIL ALARM DISABLED PERIODIC 'TEST FAIL ALARM DISABLED GROSS TEST FAIL ALARM DISABLED ANN TEST AVERAGING: OFF PER TEST AVERAGING: OFF TANK TEST NOTIFY: OFF TNK TST SIPHON HREAX•.:OFF DELIVERY DELAY 5 MIN PUMP THRESHOLD 10.00% T 2:DIESEL PRODUCT CODE THERMAL COEFF TANK DIAMETER TANK PROFILE FULL VOL T 3 :pREr1IUP1 3 2 PRODUCT CODE :•000700 :.000450 THERMAL COEFF : 11Sf. ?5 1I3.75 TAI4K DIAMETER 1 PT 1 PT TA11K PROFILE 10074 5037 FULL VOL FLOAT SIZE: WATER WARNING HIGH WATER LIMIT: MAX OR LABEL VOL: OVERFILL LIMIT HIGH PRODUCT DELIVERY LIMIT : LOW PRODUCT LEAK ALARM LIMIT SUDDEN LOSS LIMIT TANK TILT PROBE OFFSET 4.0 IN. 2.0 3.0 5037 90, 4533 95% 4785 10% 503 500 99 : 50 0.00 0.00 FLvA'f SIZE: 4.0 111, WATER WARNING 2,0 3.0 HIGH WATER LIMIT' MAX OR LABEL VOL: 1090% OVERFILL LIMIT 9066 HIGH PRODUCT 95 °i 9570 DELIVERY LiN1IT 10% 1007 50D LOW PRODUCT 99 LEAK ALARM L I !•1 I T SUDDEN LOSS LIMIT: 0.00 TANK TILT 0.00 PROBE OFFSET SIPHON MANIFOLDED TANKS SIPHON MANIFOLDED TANKS T#: NONE T #: NONE_ LINE MANIFOLDED TANKS LINE MANIFOLDED TANKS T #: NONE T#: N014E LEAK MIN PERIODIC: 10% LEAK MIN PERIODIC: 10% 503 1007 LEAK MIN ANNUAL 10% 10% 503 LEAK MIN ANNUAL 1007 PERIODIC TEST TYPE STANDARD ANNUAL TEST FAIL ALARM DISABLED PERIODIC: TEST FAIL ALARM DISABLED GROSS TEST FAIL ALARM DISABLED ANN TEST AVERAGING: OFF PER TEST AVERAGING: OFF TANK. TEST NOTIFY: OFF TNK TST SIPHON EREAK:OFF DELIVERY DELAY 5 MIN PUMP THRESHOLD 10.00% PERIODIC TEST TVPTANDARD ANNUAL TEST ALARM DISABLED PERIODIC TET GROSS TEST ALARM DISABLED ANN TEST AVERAGING: OFF PER TEST AVEF.AG I i1G : OFF TANK TEST NOTIFY: OFF TNK TST SIPHON BREAK:OFF DELIVERY DELAY 5 MIN PUMP THRESHOLD : 1.0.00% y LEAK TEST METHOD TEST MONTHLY : ALL TANK WEEK 1 MON START TIME : 2:00 AM TEST RATE :1.20 GAL /HR DURATION : 2 HOURS TST EARLY STOP:DISABLED LEAK TEST REPORT FORMAT ENHANCED LIQUID SEI'ISOR SETUP iL 1:87 STP i:.TRI -STATE (SINGLE FLOAT) :CATEGORY : STP SUMP f L 2:87 ANNULAR 'TRI -STATE (SINGLE FLOAT) CATEGORY : ANNULAR SPACE i L 3:87 FILL TR.I -STATE (SINGLE FLOAT) CATEGOR`! : PIPING SUMP L 4:DSL STP TRI -STATE (SINGLE FLOAT) CATEGORY : STP SUMP L 5 : DSL -91 ANh•IULAR TRI -STATE (SINGLE FLOAT) CATEGORY : ANNULAR SPACE l L 6:DSL FILL 1' TRI -STATE (SINGLE FLOAT) CATEGORY : PIPING SUMP L 7:91 STP TRI -STATE (SINGLE FLOAT) CATEGORY STP SUMP L 8:91 FILL TRI -STATE ( S I I•IGLE FLOAT) CATEGORY : PIPING SUMP OUTPUT -RELAY SETUP - R 1:87 TYPE: STANDARD NORMALLY CLOSED TANK #: 1 LIQUID SENSOR ALMS L 1:FUEL ALARM L 2:FUEL ALARM L 3:FUEL ALARM L 1:SENSOR OUT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD SETUP FAIL ISD SENSOR OUT FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 2:91 TYPE' STANDARD NORMALLY CLOSED TANK #: 3 LIQUID SENSOR ALMS L 5:FUEL ALARM L ?:FUEL ALARM L 7:SENSOR OUT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD SETUP FAIL ISD SENSOR OUT FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL AI.L:FLOW COLLECT FAIL R 3:DSL TYPE: STANDARD NORMALLY CLOSED TANK 0: 2 LIQUID SENSOR ALMS L 4:FUEL ALARM L 5:FUEL ALARM L 6:FUEL ALARM L 4:SENSOR OUT ALARM R. 4 : OVERF 1 LL TYPE: STANDARD NORMALLY OPEN TANK #: NONE IN -TANK ALARMS ALL:OVERFILL ALARM ALL:HIGH PRODUCT ALARM ALL:MAX PRODUCT ALARM EVR. /ISD SETUP EVR TYPE: VACUUI°I ASSIST VACUUM ASSIST TYPE HAALY VAC NOZZLE A/L RANGE MAX: 1.15 111 N: 0.95 VAPOR PROCESSOR TYPE NONE ANALYSIS TIMES TIME: 11:59 PM DELAY MINUTES: 1 ACCEPT HIGH ORVR: DISABLED ISD HOSE TABLE METER IIAP ID ID FP FL HL AA RR 01 01 01 - 02 - 01 UU 02 02 02 02 01 UU 03 03 03 02 02 UU 04 04 04 02 02 UU 05 05 05 02 03 UU 06 06 06 02 03 UU 07 07 07 02 04 UU 08 08 08 02 04 UU ISD AIRFLOW METER IIAP ID SERIAL NUM LABEL REGULAR ------------------------ 1 25191 DISP 1 -2 A 2 25175 DISP 3 -4 A 3 25185 DISP 5 -6 A 4 25193 DISP 7 -8 A ISD FUEL GRADE HOSE MAP 1 2 3 4 FP MHH MHH MHH MHH AA 01 101 201 901 U U 1 02 102 202 902 U U 1 03 103 203 903 U U 2 04 104 204 904 U U 2 05 1105 °205 905 3 U 3 06 106.206 906 3 U 3 07 167 207 907 U U 4 08 108 208 908 U U 4 LABEL TABLE 1: UNASSIGNED 2: BLEND3 3: REGULAR 4: MID GRADE 5: PREPI I UM 6: GOLD 7: BRONZE 8: SILVER 9: BLEND2 10: BLEND4 s I :LISP 1-2 AFM CATEGORY AIR FLOW METER s 2:DISP 3 -4 AFM CATEGORY AIR FLOW METER s 3:DIEP 5 -6 AFM CATEGORY AIR FLOW METER s 4:DISP 7 -8 AFM CATEGORY AIR FLOW METER s 5:D1SP 5 -6 PS CATEGORY VAPOR PRESSURE K '~C SETUP 1C VERSION: 01,Ul �POR PROCESSOR TYPE )NE 'OCESSOR CONTROL LEVEL: NE ,ARm HISTORY REPORT 4--- SENSOR ALARM - - - -- .1 :87 STP 'P SUMP ?I'•IaOR. OUT ALARM .V 10. 2011 9 :41 AM 1EL ALARM )V 10. 2011 9 :27 AM NSOR OUT ALARM T 26. 2010 12:34 R ;I-A M HISTORY REPORT -- -- SENSOR ALhQ -j - - - -- 2:87 ANNULAR NNULAR SPACE ENSOF, OUT ALARM 3V 10.. 2011 9:41 Art 4EL ALARM 3V 10, 2011 9 :28 All : EL ALARM rT 26. 2010 12:49 Phi LHRi7 HISTORI'. REPORT - SENSOR ALARr1 - - -__ 3'87 FILL "I P I NG SUr1F ENS" OUT ALhRtl V 10, 2011 9:41 Atvl JEL PLARth `V 10, 201 1 9:27 f NM NSOR OUT ALAkm T tar 2010 I2:3 t 3a PM f I ALARM HISTORY REPORT - - - -- SD SOR ALARM -- --- L 4:DSL STP STP SUMP SENSOR OUT ALARM Nov 10. 2011 9:41 AM SENSOR OUT ALARM OCT 26, 2010 12:34 PM FUEL ALARM OCT 26. 2010 12:22 PM ALARM HISTORY REPORT `- SENSOR ALr Rt°i ----- L 5:DSL'91 ANNULAR ANNULAR SPACE SEAI.SOR OUT ALARM NOV 10, 2011 9:41 A'rJ FURL ALARM NOV 10. 2021 9 :30 AM FUEL ALARr1 OCT 26, 2010 12 :48 PM ALARM HISTORY REPORT -` - -- SENSOR ALARM ----- L 6: " L FILL PIPING SUMP SENSOR OUT ALARM NOV 1Q, iQl2 9:41 AM SENSOR OUT OCT 26.2010 121:134 PM FUEL ALARM OCT 26, 2010 12 :24 Pt °t ALARM HISTORY REPORT -_ SENSOR ALARM - - - -- L 7:91 STP STP SUt°1P SENSOR OUT ALARK NOV 10, 2011 9:41 AM FUEL ALARM NOV 10, 2011 9:2r, AI °1 SENSOR OUT ALARM OCT 26. 20I0 12:34 Phi ALARM HISTORY REPORT SEfiSOR. ALARM - - - -_ L 8 :91 FILL PIPING SUMP SENSOR OUT ALARM NOV 10, 2011 9 :41 AM FUEL ALARM NOV 10, 2011 9:26 AM FUEL ALARM JUN 17. 2011 7:38 AM MONITOR CERT. FAILURE REPORT SITE NAME: HOWARDS MINI MART DATE: 11 -10 -11 ADDRESS: 4201 BELLE TERRACE TECHNICIAN: RIC1014ILLIPS CITY: BAKERSFIELD SIGNATURE: REPAIRS: NONE PARTS INSTALLED: NONE THE ABOVE NAMED PERSON TAKES FULL RESPONSIBILITY OF NOTIFYING THE APPROPRIATE PARTY TO HAVE CORRECTIVE ACTION TAKEN TO REPAIR THE ABOVE LISTED PROBLEMS AND NOTIFYING RICA ENVIRONMANTAL FOR ANY NEEDED RETESTING. THIS ALSO RELEASES RICH ENVIRONMENTAL OF ANY FINES OR PENALTIES OCCURING FROM NON - COMPLIANCE. A COPY OF THIS DOCUMENT HAS BEEN LEFT ON -SITE FOR YOUR CONVIENENCE.