Loading...
HomeMy WebLinkAboutAST 11-8-12HOODS ALARMS SPRINKLER SYSTEMS 9 ° PRAV CR OO) TH AST UST Permit No. Permit No. Permit No. Permit No. Permit No. Permit No. .— oac-5-35 Fite Number: Qt ?R 7,(- Address: 3 1;�nlc e c ( Bakersfield, CA 933 Date Received: /! —�f' -- / 2— Business Name: 00s; i c-o SYSTEM: BUILDING SQUARE FE F INSPECTION New Mod. ❑ ❑ Commercial Hood System ❑ ❑ (Fire Alarm System ❑ ❑ Fire Sprinkler System ❑ ❑ Sp air Fivush Sv; em ❑ Aboveground Storage Tank ❑ ❑ Underground Storage Tank minor '1 N modification Underground Storage Tank removal Underground Storage Tank ❑ ❑ Other. Comments: Building Sq. Feet: Calculation Bldg. Sq. Ft: 9. Z. 3. 4. Date Time f/11- -- Signature Signature s� s> `lam //3 � r S�EPtP� '1 N - 7 14113 C-4 Y//��c.,�s JAG ;►' ANEZ✓ f/11- -- Signature Signature s� s> ABOVEGROUND STORAGE TANK DINSTALL [:] REMOVE PERMIT # A7-166" b�S BCE #10866 BAKERSFIELD FIRE DEPARTMENT Prevention Services FIRE 2101 H Street A&rm f Bakersfield, CA 93301 Phone: 661 - 326 -3979 . Fax: 661 - 852 -2171 Page 1 of 2 FACILITY NAME Costco Gasoline (Loc. No. 688) ADDRESS 3800 Roseville Highway, Bakersfield, CA 93308 OPERATOR NAME Costco Wholesale PERMIT TO OPERATE # OWNER NAME Costco Wholesale # OF TANKS TO BE INSTALLED 1 /REMOVED TANK # CONTENTS VOLUME 4 (3 existing LISTS) LUBRIZOL 9888 (Fuel Additive) 1,200 Gallons NAME OF COMPANY INSTALLING AND /OR REMOVING TANK Jones Covey Group, Inc. MAILING ADDRESS 595 Lucas Ranch Road, Suite 100 Rancho Cucamonga, CA 91730 NAME & PHONE # OF CONTACT PERSON Walter Friesen / (951) 312 -4399 DATE & TIME TANK IS TO BE INSTALLED /REMOVED TB D SIGNATURE OF AP CANT DATE APPROVE Y ' DATE FD2081 (Rev 05/10) 78815 :ity of Bakersfield Check Number: 78815 Date: 11/13/2012 Check Amt: $1180.00 Tran H Invoice Type Date Reference Balance Discount Pay Amount 77625 111312 -MK Invoice 11/13,/12 10866:6- Costco .$180.00 $0,:00 $1180:0'0 I a r 4;7" i ftt 5 � z;. J: t 3,.1' �: S 4. �f�F t M � 3 ?_�7 w`' 'fn ''Z� 1 i�..( rte?} i '�d4 1 � � .A f� �i � ".✓ J 1 A't La t„"'. +11 k�" L t . i � Nor.{ - �4 1' •ax. :%�. �?g _>.j� '�', `' cf- +- fi ..,d 4?i' `�,�L�B t n.'+r�°Y �a .A'?i � r' �, . i`C<�i� r i tr y. : A w "r�`"oFj ♦ v f;- "',;;ii'f'r. �i "�'A '� %ti�''R'r' i, 1 -7- � �T E NORTHW T L'`EADER'INt, NGINEERING SERVICES SIN 1982 H a k k Nx �y.a,' n ., • . '+- ar'?tf '! f a � .rr ct � � sx1 rs � - t t'+rr 5 >. : y+., � .c- ..�. � ankF Kt 786,15 BARGHAUSEN,CONSULTING�ENGINEERS ;,INC. 1 2 ar, 1H9o= u1� 0 /B-1> _ e2e5k 0 9 8215 72nd AVENUE SOUH 1-8002672-'3555 tir f KENTWA 98032 �rk (425)5 6222 f " bit Exactly One-,h.un, eighty and no / 1 °00 {Dol- 1 "ars' ". f { Date Check No,' � Amo nt� . z 11/13/20 2" 78815 f $180 0; , PAY - - ToTHE:;City wofk Bakersfield. } ORDER, et OF Bakersfield -CA 49; ( fY G C _-. Y -� i - � d4 ,f" '\ 'FYI 1 H �'�'•f 2'[ � �"'t/ � JQtZ 1110 788• L SO �i: L 2 5000 LO Si: 5i: L 5 3 50 LO 512.7 Lno ABOVEGROUND STORAGE TANK *INSTALL [:] REMOVE PERMIT # 7 BCE#10866 BAKERSFIELD FIRE DEPARTMENT Prevention Services JAR 1K FIRM 2101 H Street ARyNAVIF Bakersfield, CA 93301 Phone: 661-326-3979 • Fax: 661-852-2171 44001� Page 1 of 2 FACILITY NAME Costco Gasoline (Loc. No. 688) ADDRESS 3800 Roseville Highway, Bakersfield, CA 93308 OPERATOR NAME Costco Wholesale PERMIT TO OPERATE OWNER NAME Costco Wholesale # OF TANKS TO BE INSTALLED /REMOVED 1 i I , '47- Ir TANK , VOLUME 4 (3 existing UST I s) LUBRIZOL 9888 (Fuel Additive) 1,200 Gallons NAME OF COMPANY INSTALLING AND/OR REMOVING TANK Jones Covey Group, Inc. MAILING ADDRESS 595 Lucas Ranch Road, Suite 100 Rancho Cucamonga, CA 91730 NAME & PHONE # OF CONTACT PERSON Walter Friesen (951) 312-4399 DATE & TIME TANK IS TO BE INSTALLED/REMOVED TBID SIGNATURE OF C 9ANwk 40/rZ5�il' DATE APPROVE DATE FD2081 (Rev 05/10) Q�G1 -1i4 V�� m r 2 o U. ti s '•�• L�T'�G ENG1N�Fi Howard Wines Bakersfield Fire Department Prevention Services 2101 'H' Street Bakersfield, CA 93301 CIVIL ENGINEERING, LAND PLANNING, SURVEYING, ENVIRONMENTAL SERVICES November 14, 2012 STANDARD FEDERAL EXPRESS (661) 326 -3979 RE: Aboveground Storage Tank Application Costco Gasoline - Fuel Additive Program 3800 Rosedale Highway, Bakersfield, California 93308 Costco Loc. No. 688 / Our Job No. 10866 Dear Howard: On behalf of Costco Wholesale, Barghausen Consulting Engineers, Inc. is submitting documentation for review and approval of the fuel additive equipment to be installed at the above - referenced Costco Gasoline facility. The project includes the installation of a 1,200- gallon automated aboveground fuel additive storage tank system, which includes minor excavation for the piping, access to the existing underground storage tank sumps, and access to spare conduits. For work associated with the installation, the estimated project valuation is $105,000. The fuel additive stored in the aboveground storage tank, LUBRIZOLO 9888, is a Class I flammable liquid and will be mixed with the gasoline in the existing aboveground storage tanks. The U.S. Environmental Protection Agency (EPA) requires use of deposit control additives, such as LUBRIZOL@ 9888, in all gasoline to keep engines clean for reduced emissions. LUBRIZOLO 9888 meets all EPA requirements for deposit control additives. Costco Wholesale has tentatively selected Jones Covey Group, Inc. as the General Contractor for the overall program. A final contractor selection process for this specific site cannot be initiated until we receive direction from your office as to the plan comments and /or corrections. Therefore, Costco Wholesale would like to proceed with the submittals without the final bid award until we have received comments and have the installation plans detailed according to your specifications. Enclosed are the following items for review and approval: 1. One (1) copy of Costco Wholesale Agent Authorization letter, dated December 16, 2011 2. One (1) copy of the Scope of Work — Option AST 3. One (1) signed Application for Aboveground Storage Tank Installation 4. One (1) check issued by Barghausen Consulting Engineers, Inc., in the amount of $180, made payable to the City of Bakersfield to cover the plan review fees 5. Two (2) sets of the Manufacturers' Cut Sheets — Option AST 18215 72ND AVENUE SOUTH KENT, WA 98032 (425) 251 -6222 (425) 251 -8782 FAX BRANCH OFFICES ♦ OLYMPIA, WA ♦ TEMECULA, CA ♦ WALNUT CREEK, CA www.barghausen.com Howard Wines Bakersfield Fire Department Prevention Services -2- November 14, 2012 6. Two (2) copies of the Material Safety Data Sheet for LUBRIZOLO 9888 7. Two (2) sets of plans prepared by Barghausen Consulting Engineers, Inc. showing the parts and piping, dated November 13, 2012 8. Two (2) copies of the California State Water Resources Control Board letter, dated February 2, 2012 9. Two (2) sets of the Manufacturers' Affirmative Statement of Compatibility It is our understanding that the items referenced above comprise a complete package for the installation of the Fuel Additive equipment and the retrofitting of the existing gasoline storage tanks. If you need additional information or require additional items for your review, please contact me via email at ainigues @barghausen.com or by telephone at (425) 251 -6222. Thank you. Respectfully, M. Alexia Inigues Project Planner MAI /ADD /jss 10866c.023.doc enc: As Noted cc: David H Rogers, Costco Wholesale Jay S. Grubb, Barghausen Consulting Engineers, Inc. Daniel B. Goalwin, Barghausen Consulting Engineers, Inc. John Ellingsen, Barghausen Consulting Engineers, Inc. Chris M. Tebaldi, Barghausen Consulting Engineers, Inc. Alexia D. Dorsch, Barghausen Consulting Engineers, Inc. C &4 0 WliOIESALE December 16, 2011 RE: Agent Authorization for Barghausen Consulting Engineers, Inc. Costco Fuel Additive Program Costco Gasoline To Whom It May Concern: Costco Wholesale Corporation hereby, authorizes Barghausen Consulting Engineers, Inc. and their designated personnel under their employment to act on our behalf for the purposes of processing all land use entitlement and development permit related documents where Costco Wholesale Corporation Is the legal property owner of record In any district within the United States and Canada. Work may also include representation at entitlement hearings or planning meetings for design review and similar services. Please call me at (425) 313 -8100 should you have any questions on this matter. Respectfully, David H Rogers Real Estate De elopment D NOTARY On this AA day of December, 2011, before me; the undersigned, a Notary Public in and for the State of Washington, duly commissioned and sworn personally appeared ;)4JOP ;4- P... S known to me to be the duly authorized representative of Costco Wholesale, the corporation that executed the foregoing Instrument, and acknowledged said instrument to be the free and voluntary act and deed of said corporation, for the purposes therein mentioned, and on oath stated that he was authorized to execute said instrument. WITNESS my hand and official seal hereto affixed the day and year in the certificate above written. JENNIFER J. SPADAFORA ( gnature) U NOTARY PUBLIC STATE OF WASHINGTON Q COMMISSION EXPIREt -nil J NOVEAiRER 19. 201i (Printed Name) NOTARY PUBLIC in and for the State of Washington residing at &u (, p My commission expires: 11-10121-3 999 Lake Drive • Issaquah, WA 98027 • 4251313 -8100 • www.costco.com r SCOPE OF WORK Costco Gasoline -Fuel Additive Program Costco Wholesale is seeking a permit to install a 1,200 - gallon aboveground fuel additive storage tank at their existing Costco Gasoline fueling facility. The purpose of the aboveground tank is for the storage and dispensing of a proprietary fuel additive into the gasoline product. The fuel additive is a Class I -C flammable liquid. The fuel additive is a fuel enhancement to improve fuel efficiency and engine performance. Most retail gasoline includes additives that have solvent/lubricant mixture compositions that are unique to that particular brand. While the mixture is proprietary it is similar to the additives used by other petroleum companies. This product meets the requirements of the U.S. Environmental Protection Agency (EPA) and California Air Resources Board (CARB) for additives. The 1,200 - gallon aboveground tank (AST) is a UL -2085 listed protected, concrete - lined, double -wall steel tank, with 110% containment. The new aboveground tank will be piped underground into a monitored single wall fiberglass transition sump where it will transition to a double wall fiberglass pipe that will extend into each of the existing gasoline fill sumps. Delivery of this product to the site will occur via delivery tanker trucks. From the delivery tanker truck the additive is transferred to the storage tank by pressurized operation through flexible hosing and tight fill connection. Before gasoline is brought to the site and delivered into the existing underground gasoline storage tanks (UST) the "Costco Gasoline" attendant will program the new batch controller panel in the controller enclosure to inject a pre- determined amount of additive into each individual gasoline tank (e.g., 3.5 gallons of the liquid additive into Tank #1, etc.). Once the additive is in the USTs, the gasoline product is then delivered into the tanks resulting in the combined additive - gasoline mixture. The specific scope of the work to be performed as part of the aboveground installation is as follows: • Install one (1) 1,200 - gallon UL -2085 concrete -lined double -wall steel aboveground tank, with 110% containment, for Class I -C liquid. Tank is pre - assembled with mechanical level gauge, lockable 15- gallon fill containment box and fittings, overfill protection drop tube, and emergency vents • Remove approximately one -third of the existing UGST slab to accommodate the piping modification. • Replace the existing tank manway lids at each existing gasoline fill sump to include additional bungs. • Install 2" double -wall fiberglass product manifold line from the new transition sump at the 1,200 - gallon additive AST, to the existing gasoline fill containment sumps. Slope the new additive piping down to the transition sump. • Install 6" structural support slab for tank. Install additional concrete access walkway and curbing as may be required (when applicable) • Install Veeder -Root electronic annular sensor and automatic tank level gauge, and program panel for high level alarm. • Install bollards as may be required (when applicable) • Install "Flow Dynamics" Batch controller panel in the existing controller enclosure. • Install a flow meter at the new 1,200 - gallon additive AST turbine's discharge. • Install one (1) new 24 -volt solenoid valve at each existing gasoline fill sump. • Install one (1) conduit and wiring for electrical power to solenoid valves at existing gasoline fill sumps. Install one (1) conduit with power wiring to new 1,200 - gallon additive AST for turbine pump power. Install one (1) new conduit and data wiring to new 1,200 - gallon additive AST for 6213 CA scope Class I -C liquid- AST.doc flow meter sensor. Install one (1) conduit and wiring to the new transition sump and 1,200 - gallon AST for sump monitoring, annular monitoring and automatic tank gauge. New conduits to be equipped with seal -offs at hazardous zones. • Install new single wall piping transition sump with Veeder -Root sensor at lowest point. • Adjust landscaping and restore as required (when applicable). • Patch and repair asphalt as may be required. 6213 CA scope Class I -C liquid- AST.doc ABOVEGROUND STORAGE TANK GUIDELINES FOR PERMIT TO INSTALL /REMOVE AST FOR DISPENSING OF FLAMMABLE OR COMBUSTIBLE LIQUIDS AND CONDITIONS FOR CLOSURE, EXCAVATION, REMOVAL & DISPOSAL, SOIL SAMPLING, PRELIMINARY SITE ASSESSMENTS i3 <�i1`i „-- BAKERSFIELD FIRE DEPARTMENT Prevention Services 2101 H Street Bakersfield, CA 93301 Phone: 661-326-3979 • Fax: 661-852-2171 Page 2 of 2 GUIDELINES FOR PERMIT TO INSTALL AN AST FOR DISPENSING OF FLAMMABLE OR COMBUSTIBLE LIQUIDS 1. Any aboveground storage tank installed within the City of Bakersfield for the purpose of Dispensing motor vehicle fuels must meet the requirements of Section 2206.2.3 (1) of the California Fire Code, 2007 Edition and Bakersfield Municipal Code. 2. The tank sizes shall not exceed a capacity of 12,000 gallons individual or 48,000 gallons aggregate. 3. Any aboveground storage of petroleum with a cumulative capacity of more than 1,320 gallon must complete a Spill Prevention, Control and Countermeasure (SPCC) Plan, per California Health & Safety Code Division 20 Chapter 6.67. A copy of this plan must be submitted to the Bakersfield Fire Department Office of Prevention Services located at 2101 H Street, Bakersfield, CA 93301 and can be reached at 661 - 326 -3979. APPLICATION PROCESS 1. Provide two sets of a plot plan for the facility. This plan must include location of property lines, all buildings and openings to each building (i.e., windows, doors, vents, etc.), nearest road or intersection, all tanks piping, any fixed source of ignition (i.e., water heaters, forced air, AC units, etc.), all foundations, and equipment to be installed. 2. Construction details of tank pad seismic straps or fixtures, and crash posts. 3. Certification by the manufacturer that the tank meets the applicable codes. 4. Identification of the material to be stored in the aboveground storage tank. 5. Building permits for all reinforced concrete and electrical work must be obtained at the Bakersfield City Building Department located at 1715 Truxtun Avenue, Bakersfield, CA 661 - 326 -3720. Construction cannot begin without their approved permit. 6. Complete any necessary application for the Air Pollution Control District for any storage or dispensing of gasoline or aviation fuel. 7. Applications must be fully completed or they will be returned - no exceptions. 8. Permit fee must be submitted with the application or the application will not be processed. 9. A final inspection must be completed before AST system is operational. This is to ensure compliance with the UFC regarding placement of placards, and where applicable, the testing of emergency shut -off device, and overfill /overspill. GUIDELINES FOR PERMIT TO REMOVE AN AST 1. Tanks may not be removed without an inspector present. 2. Tanks shall be either decontaminated or transported as hazardous waste. 3. A Hazardous Waste manifest will accompany either the rinseate or the tank and shall be present on site and presented upon request. 4. The interior of tanks being transported not as hazardous waste (decontaminated) shall have a lower explosive limit (LEL) of no greater than 5 percent immediately following cleaning and prior to the introduction of carbon dioxide (CO'). 5. The contractor shall certify on the inspection form that the cleaning process was properly conducted and the LEL results did not exceed 5 percent. 6. The decontaminated tank shall be inerted with the introduction of COz, in the form of dry ice or from canisters. 7. A rate of 20 pounds of dry ice to 1,000 gallons of tank capacity, or the corresponding weight of COZ. 8. If canisters are used, they shall be bonded to the tanks. 9. A receipt for the CO2 shall remain on site and presented upon request. 10. Prior to the removal of a decontaminated tank the LEL level will be no greater than 5 percent and the oxygen level will be no grater than 9 percent. SOIL SAMPLING /PRELIMINARY SITE ASSESSMENT 1. Soil samples shall be obtained under the direction of a professional engineer, geologist, or authorized representative of a State- approved laboratory. 2. Samples shall be collected, at a minimum, from depths of 2 and 6 feet below the tank bottom, dispensers, and product lines and from the following locations (unless waived by the local agency inspector on site): A. From the center of the tank. B. Below all dispensers. C. Piping - every 20 feet and /or at connections, joints, bends, etc. 3. Any area of obvious contamination of likely areas of contamination may be required to be sampled. 4. All samples shall be analyzed by a State - certified laboratory. 5. Soil samples shall be analyzed for all known and suspected substances to have been stored in the tank. Additionally, methyl tertiary butyl ether (MTBE) shall be analyzed in all soil samples taken from beneath tank systems which contained any motor vehicle fuel. 6. All samples will be accompanied by a Chain -of- Custody sheet. 7. A soil sample report/preliminary assessment shall be submitted to the Office of Prevention Services within 5 days after results have been received and shall contain at a minimum the following information. A. Name and location of where tanks were disposed. B. Name and location of where rinseate was disposed. C. A signed copy of the Hazardous Waste Manifest. D. A tank disposal receipt from the scraping facility. E. Copies of all lab data sheets and Chain -of- Custody documentation. F. A plot plan showing the location of buildings, tanks, piping runs, dispensers, and ALL SAMPLE LOCATIONS WITH CORRESPONDING I.D. NUMBERS AND DEPTHS. FD2081 (Rev 05/10) Fueling System Catalog Cut Sheets ADDITIVE TANK SYSTEM - CALIFORNIA AST LOCATIONS June 2005 f= HOOVER MULT TM Fire Rated Double -Wall Aboveground Tanks 4� Containment Solutions, Inc. (CSI) provides safe, affordable solutions for the storage of flammable and combustible liquids. If you are concerned about the effects fuel storage has on your bottom line, look at the advantages of aboveground fire - protected storage tanks. Our steel Hoover Vault" tanks meet the requirements of all national fire codes for fire -rated aboveground storage tanks and are labeled according to Underwriter's Laboratories Standard 2085 "Insulated, Protected Secondary Containment': Vault tanks utilize patented designs with lightweight fireproofing materials, applied in the interstitial space of UL 142 double -wall tanks. These materials ensure that the inner tank is protected from the effects of fire. This design allows both the inner and the outer tanks to be pressure tested at the factory and in the field. In addition, the fireproofing materials allow liquid to migrate through to the monitoring tube, so leaks from the inner tank are detected. Rectangular vault tanks are space- saving in design. r NTAINMENT LUTIONS ITEM #1 Standard Tank Sizes 250 4'9" 37" 500 6'8" 47" 1,000 7'9" 57" 1,500 107' 5'11" 2,000 11'10" 6'11" 2,500 9'5" 6'11" 3,000 918" 7'11" 4,000 12'8" 7'11" 5,000 15'8" 7'11" 6,000 18'8" 7'11" 8,000 24'8" 7'11" 10,000 30'8" 7'11" 12,000 36'8" 7'11" 15,000 45'8" 7'11" 20,000 60'8" 7'11" 3'9" 3'9" 4'9" 4'9" 4'9" 7'1" 7'1" 7'1" 7'1" 7'1" 7'1" 7'1" 7'1" 7'1" 7'1" 3,400 LBS. 5,400 LBS. 8,500 LBS. 10,250 LBS. 12,500 LBS. 13,100 LBS. 15,800 LBS. 19,000 LBS. 23,700 LBS. 27,000 LBS. 33,450 LBS. 42,600 LBS. 48,750 LBS. 60,400 LBS. 76,900 LBS. Vault Tank Options • UL 142 listed double -wall inner tank, Steps and 1 - providing triple containment Handrail Assembly • Larger tank capacities up to 30,000 gallons • 3,000 PSI concrete • Stainless steel inner tanks • Dual for compartments multi - purpose use available in all capacities • Lifting lugs and pump mounting brackets L.. • Fibervault® exterior coatings • Internal coatings compatible with aviation fuels and other chemicals Ground Level Spill _B' o-' ox CONTAINMENT SOLUTIONS U� 5150 Jefferson Chemical Road • Conroe, TX 77301 • Phone: (936) 756 -7731 • www.containmentsolutions.com June 2009 Copyright 2009 Containment Solutions, Inc. All Rights Reserved Pub. No. TNK 1504D • • • F IEI 5' -7„ u1 IAN 4' 111.11 OVERALL SHIPPIK DIMENSION: 11' -2' L X 6'2' W X 6' -2' H TOP VIEW 9' -18„ ELEVATION F 6' ITEM SIZE SUGGESTED FUNCTION 1 4' PHASE 1 VAPOR RECOVERY SPARE 2 2' MECHANICAL GAUGE 3 4' ELECTRONIC LEVEL GAUGE 4 2' SUCTION PUMP SPARE 5 4' FILL 6 2' PRIMARY WORKING VENT 7 6' PRIMARY TANK EMERGENCY VENT 8 2' SPARE 9 4' SPARE 10 2' SECONDARY WORKING VENT 11 6' SECONDARY CONTAINMENT EMERGENCY VENT 12 2' SECONDARY MONITOR PIPE 13 4' FIRE RATED MATERIAL FILL 14 2' X 2' GROUND CUP, DWG. °MCB004' 15 FP2 SIMPLEX BOX, DWG.'SBB004' 16 FR -702 BRACKET W COUPLING, DWG.'PBB008' THREADED CONNECTION (TYP.) SEE TOP VIEW 3 11 1 I 1 Iii" TANK SPECIFICATIONS VENTING CAPACITY: PRIMARY TANK — 168,000 CUBIC FEET PER HOUR SECONDARY TANK — 211,000 CUBIC FEET PER HOUR MATERIAL- PRIMARY TANK — 3/16' THICK SECONDARY TANK — 3/16' THICK SEAL WELD ALL FITTINGS AND TANK 6' -2" END VIEW 4" SPACE BETWEEN INNER & OUTER TANKS FILLED WITH LIGHT WEIGHT FIRE —RATED MATERIAL I I" DI c NOTE: e ALL UNUSED FITTINGS TO HAVE A CAST IRON CAP OR PLUG. PRODUCT CODE GALLONS DESCRIPTION OVERALL SIZE SHIP WT. �V4AA112CV8504 1,200 U/L -2085 ABOVE GROUND VAULT TANK 9' -0" L X 5' -7" W X 4' -9" H 9,800 LBS. O NTAI N M E N THIS DRAWING AND DESIGN SHOWN HEREIN IS THE PROPERTY OF CONTAINMENT SOLUTIONS. USE OR COPIES THEREOF CANNOT BE MADE WITHOUT WRITTEN CONSENT. A CUSTOMER NAME DRAWN BY: D. ROVANG DATE DRAWN:06 -24 -10 A APPROVED BY: DATE: DWG NUMBER: 5104191 SCALE: 1:36 COSTCO REV: I REV BY: I DATE: SHEET:1 OF 1 8 1 7 6 5 4 3 2 1 The 9095A AST Overfill Prevention Valve is installed at the fill port of an aboveground storage tank. Used in a tight fill application, the valve terminates flow of product when the liquid level reaches a preset warning level (90 -95% full). The valve is installed on a standard N.P.T. male connection when used with the quick disconnect or female adaptor. When installed to manufacturers requirements the Overfill Prevention Valve can eliminate environmentally hazardous spills. A built -in bleed hole also provides anti - syphoning protection. ULC Listed. The valve can be used in conjunction with the Morrison Fig. 518 and 515 lines of AST Spill Containers for added spill protection. All models are supplied with an adaptor to mount Morrison Fig. 419 aluminum drop tubes. A test mechanism is also sold separately for denoted models. The test mechanism allows a technician to pull on the test line at any time during the filling process to actuate the float and stop the fill. This allows a technician to verify the valve is working properly. MAN I. Y 1' H WN WITH H WITH SHOWN WITH TEST This Valve Complies With the Following Codes: STANDARD FEMALE MECHANISM ADAPTOR ADAPTOR 9095ATM0100AM NFPA 30, 30A, UFC, BOCA, SBCCI /SFC and PEI /RP2000 9095A -0200 AV or 9095A- 3200AV or Product Warnings and Cautions: • 5 PSI & 5 GPM is the minimum flow requirement for valve operation at the following maximum viscosities (in centistokes): 2" Valve -150 3" Valve -60. • Maximum flow rate of the 2" valve is 125 GPM at 100 PSI. The 3' valve is 300 GPM at 100 PSI. • The valve cannot leak more than 1.5 GPM. • A tight fill is required for the valve to operate. Do not substitute any other fill adaptors for the special adaptor supplied. • The valve must be used with clean product. Debris from products such as contaminated waste oil may cause the valve to function improperly. • Consult Morrison Bros. Co. for product compatibility with the valve. • The 3' valve can be used w /6' Sch. 40 or 80 pipe. • The 2" and 4" valves can only be used with Sch. 40 pipe. • These valves are rated for a maximum pressure of 100 PSI. • Not suitable for motor oil or other heavy oils. Failure to follow any or all of the above warnings may render the valve non -func- tional and could result in a hazardous product spill, which may result in personal Injury, property damage, fire, explosion or environmental contamination. Spec Ification/DetaII Options: A —Body Size: 2" N.P.T. (2'), 3' N.P.T. (3') (BSP Models Available) B— Adaptor : (2S): 2' x 4' Standard 2' Male Disconnect x 4' Female (2X): 2" Quick Disconnect Adaptor (2D): 2" x 2' x 4' Female Ductile Iron Adaptor (3S4): 3' x 4" Standard 3' Male Disconnect x 4' Female (3F): 3" x 4' Standard 3' Female x 4' Female With Line Purge (3S): 3" x 6' Standard 3' Male Disconnect x 6' Female (3X): 3' Quick Disconnect Adaptor (3D): 3' x 3' x 6' Female Ductile Iron Adaptor C—Gasoline Shutoff Height From Top of Valve (Inches) D— Diesel Shutoff Height From Top of Valve (Inches) E —Test Mechanism: Yes (Y) or No (N) HT.— Height: Dimension from base to top of valve (Inches) WT.— Shipping Weight (lbs.) Body: Anodized Aluminum Internal Components: Brass/Stainless Steel Linkage: Stainless Steel LAMorrison Bros. Co. Established 1855 9095A -0300 AV Adaptor (B) Body Size Linkage Floats Drop Tube Adaptor \ (For Morrison Fig. 419 Drop Tube) Specification Options: 9095A- 3300AV Nipple Test Mechanism Gas (C) I Diesel (D) (HT.) I.D. NUMBER A B C D E HT. WT. 9095A -0200 AV 2" 2S 11 12 Y 19.25 14.1 9095A -3200 AV 2" 2D 11 12 Y 19.25 14.1 9095A -0500 AV 2" 2X 11 12 N 19.25 12.6 9095A -0300 AV 3" 3S 13.56 13.75 Y 19.56 29 9095A -0600 AV 3" 3X 13.56 13.75 N 1 19.561 26 9095A -3300 AV 3" 3D 13.56 13.75 Y 19.561 38 9095A -4000 AV 2" 3S4 11.67 12.67 N 19.9 9095A -4200 AV 2" 3F 11.67 12.67 N 19.9 9095ATMO100 AM Mechanical Test Mechanism Assembly (Existing Valve May Require New Top for Retrofit) P.O. Box 238 • Dubuque, Iowa 52004 -0238 563.583.5701 (tel) • 800.553.4840.563.583.5028 (fax) www.morbros.com Features • Easy Installation — a 4" flexible boot on the back panel allows for a quick, simple connection to the remote fill or vapor lines. Optional reducer inserts are available to accommodate 3" and 2" piping connections. • Models to Accommodate Various Fill Pipe Configurations — available in 15, 20 and 30- gallon container capacity. Smaller 15- gallon models are designed for a single -fill or vapor return connection. Larger 20 and 30- gallon models accept both fill and vapor return piping in a dual -port configuration. The 30- gallon model will accommodate both fill and vapor return piping in a single - port configuration and allow the use of 3" Dry Disconnects (OPW 1611 AN and 1711 D) in a dual -port configuration. • Rain- Shedding Cover Design — hooded cover design helps prevent water or snow entry by extending the lip of the cover over the body of the spill container. • 12 -Gauge Epoxy- Powder Coated Steel or Stainless Steel Construction heavy -duty materials, compatible with hydrocarbons, for long service life and added security. Ordering Chart: See Pomeco Product Configurator 0yM ER�FIEU 6211 -R • Welded- Hinge, Lockable Hatch — cover includes a provision for a padlock and a welded -hinge assembly for added security. • Easy Product Drainage — lockable ball valve drain provides for quick and easy product removal. • Height Adjustable — adjustable legs enable the spill container to be set at a variety of heights, from 16'/2' to 30 ". Each leg is independently adjustable to account for uneven ground conditions. ♦ CARB Certified A Custom Sizes Available Upon Request. 1 6 1 1 R— I II II II 1 15 —15 Gallon Capacity B — Booted entry 2 — 2" Fitting 20 — 20 Gallon Capacity fittings in holes 3 — 3" Fitting 30 — 30 Gallon Capacity N — No fittings in holes 4 — 4" Fitting Note: an Item must be selected for each column. L — Adjustable legs and No base drain valve LD — Adjustable legs with base drain valve N — No legs and No base drain valve ND — No legs with base drain valve Dimensions 15 Gallon 20 Gallon 30 Gallon in_ rm In. rm In rm A 18'h �21'18S° 24 61 1 21 20 rte "` i 19 Th ( 19 j 10% 1 27 C 13% ( 35 211 —12 Gauge Powder- { 16% { 42 0 — No entry holes Coated Steel { 161h to 30 { 42 to 76 { 161h to 30 1 —1, 4" entry hole Construction 21 1S — Stainless Steel { 46 24 61 2 — 2, 4" entry holes (30 Gallon Only) Construction F 91h { 23 12 30'h 15 —15 Gallon Capacity B — Booted entry 2 — 2" Fitting 20 — 20 Gallon Capacity fittings in holes 3 — 3" Fitting 30 — 30 Gallon Capacity N — No fittings in holes 4 — 4" Fitting Note: an Item must be selected for each column. L — Adjustable legs and No base drain valve LD — Adjustable legs with base drain valve N — No legs and No base drain valve ND — No legs with base drain valve Dimensions 15 Gallon 20 Gallon 30 Gallon in_ rm In. rm In rm A 18'h { 46 1 24 61 1 21 1 53 { B 7% 19 Th ( 19 j 10% 1 27 C 13% ( 35 { 16% 42 { 16% { 42 D 16% to 30 42 to 76 { 161h to 30 { 42 to 76 { 161h to 30 42 to 76 E 18'h { 46 24 61 34 86 F 91h { 23 12 30'h 9'h { 24 G 47 to 60% 119 to 154 56% to 80 144 to 203 561h to 80 144 to 203 ITEM #5 POM 211 -RMOT Remote -Fill Above Ground Storage Tank Spill Containers POMECO /OPW Remote -Fill AST Spill Containers are designed to prevent spille product from entering soil near the remot horizontal -fill and vapor return connectior on an above ground storage tank during normal tank filling operation. The spill containers catch spillage to help prevent soil contamination and groundwater pollution. POMECO /OPW Remote -Fill AST Spill Containers slip on the remote - fill and vapor return piping connected to an above ground tank. Compatible with methanol, ethanol, jet and AV -Gas fuels. Replacement Parts Part # Description 201758 4 x 2 Reducer Insert 201759 4 x 3 Reducer Insert PBOOT Nitrile (Fuel - Resistant) Boot 202312 Aluminum Flange 21BV -0075 Fullport 14" PRMOT - LEGKIT Leg Kit 211 R Instruction Sheet Order Number: H15857PA O A �COMM W 2 U "Open" vent used on underground and aboveground tanks for petroleum storage tanks. Vent allows the tank to "breathe" during filling and dispensing operations. 1'/2" and 2" sizes are CARB approved. Vents outward and upward in accordance with NFPA 30. Note: Open vents will allow unrestricted evaporation of product. • Body: Aluminum • Cap: Aluminum • Screen: 40 Mesh Brass Figure 354 Weight Venting Capacity 1'/2" .75 Ibs 27,650 (CFH) 2" .75 Ibs 27,650 (CFH) 3" 1.5 lbs 59,000 (CFH) 4" 2.25 Ibs 116,900 (CFH) WARNING: Normal vents such as pressure vacuum and updraft vents for aboveground storage tanks should be sized according to NFPA 30 (2008) 21.4.3 WARNING: DO NOT FILL OR UNLOAD FUEL FROM A STORAGE TANK UNLESS IT IS CERTAIN THAT THE TANK VENTS WILLOPERATE PROPERLY. Morrison tank vents are designed only for use on shop fabricated atmospheric tanks which have been built and tested in accordance with UL 142, NFPA 30 & 30A, and API 650 and in accordance with all applicable local, state, and federal laws. In normal operation, dust and debris can accumulate in vent openings and block air passages. Certain atmospheric conditions such as a sudden drop in temperature, below freezing temperatures, and freezing rain can cause moisture to enter the vent and freeze which can restrict internal movement of vent mechanisms and block air passages. All storage tank vent air passages must be completely free of restriction and all vent mechanisms must have free movement in order to insure proper operation. Any restriction of airflow can cause excessive pressure or vacuum to build up in the storage tank, which can result in structural damage to the tank, fuel spillage, property damage, fire, injury, and death. Monthly inspection, and immediate inspection during freezing conditions, by someone familiar with the proper operation of storage tank vents, is required to insure venting devices are functioning properly before filling or unloading a tank. LAMorrison Bros. Co. Established 1855 P.O. Box 238 • Dubuque, Iowa 52004 -0238 563.583.5701(tel) • 800.553.4840.563.583.5028 (fax) www.morbros.com LIL Listed Emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over - pressurized and possibly rupturing if ever exposed to fire. Vent must be used in conjunction with a "normal vent." Correct application of this vent requires proper vent size and selection for the tank system in order to meet the specific venting capacity. Conformance Including: NFPA 30,30a, LIL 142, LIL 2244, API 2000 and PEI RP200. Additional References: NFPA 30, LIL 142, Morrison Venting Guide SPECIFICATION OPTIONS: I.D. NUMBER A B C D E F G DIA HT WT. 244M -0200 AV 6 246.13 M 8 1 BR AL 7.9 6.5 19.5 244OM -0200 AV 6 246.13 M 8 1 O AL 7.9 6.4 19.5 2440MI0200 AV 6 246.13 M 8 1 O 1 7.9 6.4 27.8 244M -0400 AV 6 246.13 M 16 1 BR AL 8.1 7.8 35 244OM --0400 AV 6 246.13 M 16 1 O AL 8.1 7.7 35 2440MI0400 AV 6 246.13 M 16 1 O 1 8.1 7.7 43.3 244 -0200 AV 6 246.13 8 1 BR AL 7.9 4.5 15.5 2440 -0200 AV 6 246.13 8 1 O AL 7.9 4.2 15.5 24401 -0200 AV 6 246.13 8 1 O 1 7.9 4.2 20.6 244 -0400 AV 6 246.13 16 1 BR AL 1 8.1 5.7 33.2 2440 -0400 AV 6 246.13 16 1 O AL 1 8.1 5.6 33.2 24401 -0400 AV 6 246.13 16 1 O 1 8.1 5.6 38.3 244OH -0400 AV 6 298.75 8 1 O AL 8.5 4.7 21.5 244OH -0600 AV 6 298.75 16 1 O AL 8.6 5.9 41.4 244OMHO400 AV 6 298.75 M 8 1 O AL 8.5 6.6 23.0 244OMHO600 AV 6 298.75 M 16 1 O AL 8.6 7.8 42.9 244OF -0050 AV 6 298.75 F 8 I O AL 11 3.9 24.8 244OF -0075 AV 6 298.75 F 16 I O AL 11 5 44.2 CHART KEY: A -Size: 6" B- Venting Capacity /CFH (in 1000's) C- Mounting Connection: Female N.P.T. (BLANK); Male N.P.T.(M); Flanged (F) D- Pressure Settings: 8, 10, 16 oz/in2. Pressure Required to Open Vent. E- Cover: Cast Iron Painted (1); Aluminum (AL); Optional Iron Powder Coated (Consult Factory for Details); Bolt: Steel -Zinc Plated F -Seat Material: Brass (BR) or Viton O -Ring (0) G -Body Material: Aluminum (AL) or Iron (1) Diameter- Dimension Across Vent Height- Dimension From Base to Top When Closed Weight- Shipping Weight WARNING: DO NOT FILL OR UNLOAD FUEL FROM A STORAGE TANK UNLESS IT IS CERTAIN THAT THE TANK VENTS WILL OPERATE PROPERLY. Morrison tank vents are designed only for use on shop fabricated atmospheric tanks which have been built and tested in accordance with UL 142, NFPA 30 & 30A, and API 650 and in accordance with all applicable local, state, and federal laws. In normal operation, dust and debris can accumulate in vent openings and block air passages. Certain atmospheric conditions such as a sudden drop in temperature, below freezing tempera- tures, and freezing rain can cause moisture to enter the vent and freeze which can restrict internal movement of vent mechanisms and block air passages. All storage tank vent air passages must be completely free of restriction and all vent mechanisms must have free movement in order to insure proper operation. Any restriction of airflow can cause excessive pressure or vacuum to build up in the storage tank, which can result in structural damage to the tank, fuel spillage, property damage, fire, injury, and death. Monthly inspection, and immediate inspection during freezing conditions, by someone familiar with the proper operation of storage tank vents, is required to insure venting devices are functioning properly before filling or unloading a tank. LAMorrison Bros. Co. Established 1$55 P.O. Box 238 • Dubuque, Iowa 52004 -0238 563.583.5701(tel) - 800.553.4840.563.583.5028 (fax) w w w. m o r b r o s. c o m Component: Description Calibration: Consists of 3 pieces. Inner piece, outer piece, and a calibrated piece of paper in between them. Optional: Inner Plastic piece can be glass. This helps protect from aggressive fumes and heat. Gasket: Seals the gauge to the bushing. Standard material is Duro Nitrile. Optional: Gasket can be made out of Viton Bushing: NPT male fitting that threads into your tank's female fitting. Standard material is Aluminum. Optional: PVC available. Standard size is 2 inch. Optional 1.5 inch or .75 inch are available. Locknut Red plastic locking nut tightens the calibration and the gauge to the bushing. Standard material is HDPE. Optional: Can be made of Aluminum or PVC for added durability. Standard Rod: Stationary 3/16" rod inside the tank, stabilizes the gauge. Length varies depending on tank depths and extensions. Standard material is Galvanized Steel. Also available in stainless steel, Peek Plastic, or Kynar Plastic Push Rod: Mobile 1/8" rod inside the tank, moves the red indicator up and down vertically. Length varies depending on tank depths and extensions. Standard material is Galvanized Steel. Also available in stainless steel, Peek Plastic, or Kynar Plastic. Float Rod: Mobile flat rod inside the tank, moves the push rod up and down vertically. Length varies depending on tank depths and extensions. Standard material is Galvanized Steel. Also available in stainless steel, Peek Plastic, or Kynar Plastic. Float: Attached to the float rod inside the tank. Floats on top of the liquid. Standard material is HDPE Plastic. Also available in nitrophyll or stainless steel. Sample Part'Number - D -248 D is the gauge type. 2 is the fitting size. 48 is the tank depth. In this example there is no extension. When custom ordering Direct Reading gauges: • Specify type D. • Specify Size opening. • Specify tank depth. • Specify extension length. (may be zero) • Specify non standard materials and options. Krueger Sentry Gauge 1873 Siesta Lane Green Bay, WI 54313 www.ksentry.com Extenslon length Primary tank depth Contact us for more info Ph: 920 -434 -8860 Fax: 920 -434 -8897 Email: info @ksentry.com DESCRIPTION The Morrison Fig. 346 Series External Emergency Valve is for installation at the outlet of an AST or in a liquid transfer line where product flow must be stopped in the event of a fire. Fig. 346 flanged external emergency valves conform to ANSI B16.42 specifications for class 150 raised face ductile iron flanges. Cold non - shock pressure rating is 200 P.S.I. W.O.G. for sizes 1.5', 2 ", 3" and 250 P.S.I. W.O.G. for the 4 ". Ductile iron valves are painted green and stainless steel valves are painted blue for designation purposes. SPECIFICATION / DETAIL OPTIONS A Size: In Inches B C D E Mounting Connection: Flanged (F) or Female (Blank) Body / Cap Material: Ductile Iron (DI) or Stainless Steel (SS) Gasket Material: PTFE (TFE) Poppet: Ductile Iron (DI) or Stainless Steel (SS) O -ring: PTFE Encapsulated Flourocarbon Elastomer Spring: Stainless Steel Seal Nut/Plug: Stainless Steel Handle: Brass Fulcrum Shaft: Stainless Steel Groove Pin: Steel Hold Open Hook: Stainless Steel F Lever Arm: Ductile Iron (DI) or Stainless Steel (SS) G Fuse Link: 165° F STD. (212 °F Optional); Fuse Link is UL Listed H Number of Bolt Holes Height of Valve (Inches) J Length of Valve (Inches) K Shipping Weight (lbs.) Flange gaskets, nuts, bolts and washers available LAMorrison Bros. Co. Established 1855 I.D. NUMBER A B C D E I F G H I J K 46FD10200 AV 2 F DI TFE DI DI 165 4 6.25 6.5 15 46FD10300 AV 3 F DI TFE DI DI 165 4 8.53 8.625 27 46FD10400 AV 4 F DI TFE DI DI 165 8 11.75 11.5 71 346DI-0400 AV 1.5 DI I TFE DI DI 165 5 1 5.437 4.5 346SS-01 AV 1.5 SS TFE SS SS 165 5 5.44 6 346DI-0500 AV 2 DI TFE DI DI 165 5 5.437 6.5 1216SS-0200 AV 2 SS TFE SS SS 165 5 5.44 7 6DI -0600 AV 1 3 1 1 DI TFE D11 DI 1 165 1 1 7 1 8.312 1 15 P.O. Box 238 • Dubuque, Iowa 52004 -0238 563.583.5701 (tel) • 800.553.4840 • 563.583.5028 (fax) www.morbros.com I FMF The Fig. 912 Anti - Syphon Valve is used on storage tank systems to prevent the formation of a syphon in the event of a line break or leak. The Fig. 912 will help prevent product loss, environmental contamination and/or fire hazards. The 912 has built in expansion relief of 25 PSI. The stainless steeWitone construction allows for greater fluid compatibility. The 912 is designed to be installed in the piping system above the top of the tank. A unique feature is the ability to be installed in both horizontal and vertical piping. • Wetted components: 304/316 Stainless Steel; Viton® GF • Maximum working pressure: 200 psi • Working temperature: -40 °F to 300 °F • Fluid compatability: Gasoline, Ethanol, Diesel, Biodiesel, DEF, Urea (other fluids may also be compatible with further review) I.D. NUMBER A B C WT. 912- 070500 AV .75" 5 4.85 0.75 912- 071000 AV .75" 10 9.26 0.75 912 - 071500 AV .75" 15 13.68 0.75 912 - 072000 AV .75" 20 1 18.08 0.75 912 - 100500 AV 1" 5 4.85 1.3 912 - 101000 AV 1" 10 9.26 1.3 912 - 101500 AV 1" 15 13.68 1.3 912 - 102000 AV 1" 20 18.08 1.3 SPECIFICATION OPTIONS: A— Fitting Size B—Head (Ft. of Water Column) C`— Opening Vacuum (in.Hg) WT.— Weight (Lb.) 'BSP threads are available in all sizes (9128 Series) Note: Opening vacuum values were determined by testing with water through the valve alone. All piping system losses will affect the vacuum required to pump through the valve and system. MIFF Priming Tees w/ Plugs Constructed of 304 Stainless Steel 1AMorrison Established 1855 Bros. Co. The priming tee is an optional device that allows the installer /operator to fill the piping system with fluid. This allows a prime to be established for pumps and other devices. The tee also allows an access point for system maintenance and troubleshooting, such as installing a pressure gauge. 1" MxFxF NPT Tee with Plug I.D. NUMBER Size Weight 912 - 070511 AT 0.75" 0.6 lbs. 912 - 100511 AT 1.00" 1.25 lbs. FxMxF NPT Tee with Plug I.D. NUMBER Size I Weight 912 - 070510 AT 0.75" 0.6 lbs. 912 - 100510 AT 1.00" 11.25 lbs. P.O. Box 238 • Dubuque, Iowa 52004 -0238 563.583.5701 (tel) • 800.553.4840.563.583.5028 (fax) www.morbros.com i FiV . 912 Anti'l i J 1- i Stjph0�1 Valve n @0- c us 125 G... E.R.- 93 -5 P S I G...2'/," -4" .0 LP -GAS New. * 2nd GENERATION P.T.F.E. PACKING AND SEATS -000 F TO 300'F IA U BA "DAC ROM ET" /RUST RESISTANT, RUGGED STEEL HANDLE \ FM FIRE PROTECTION C FOOD INDUSTRY 3/8" — 3/4" VIBRATION FREE SELF - LOCKING NUT © 2000 ADJUSTABLE PACKING NUT THREADED TO BODY Improving Performance ISO -EN -9002 DOUBLE VITON' O -RINGS -' �, TO PREVENT STEM LEAKAGE EXPLOSION PROOF STEM BOTTOM LOADED SOLID BALL /EXTREMELY HARD C.P. BRASS o' �71N. 4 OPTION: 316 SS BALL & STEM V1 TWO PIECE HOT FORGED BRASS BODY - ELIMINATES PINHOLES I x \t\ MODEL T -100 -N SYSTEM -6e i 2nd GENERATION PACKING/SEATS 100% FULL PORT SIZES Y411-411 150 W.S.P. 600 - 500 -400 W.O.G. V7A 1.'III ISI T/S -100 -N valves are designed for temperatures Zero Atmospheric Emissions ... up to 366° F, utilizing low pressure steam at for a Cleaner Environment. 150 WSP UNJ - U P n C3La�� TM *100% INCREASE IN INSTALLED VALVE LIFE, TROUBLE FREE MAINTENANCE / NO STEM LEAKAGE ONE VALVE MEETS ALL LOCAL CODES *IAPMO 10/29/99 HYDROSTATIC TEST... AVAILABLE UPON REQUEST 1 Bi 'n Va�ue www.jomar.com CONSOLIDATED LIST PRICE SHEET PHONE: 1-800-T6 JOMAA (865 -6627) FAX: 1-800-628-4194 EFFECTIVE FEB. 1, 2002 SUPERSEDES SEPT. 15, 2000 PRICE SHEET COMPUTER LIST CASE CTN. CASE NO. SIZE PRICE QTY. QTY. WGT. FORGED BRASS BODY CHROME PLATED BALL WITH BRASS STEM DOUBLE VITON O -RINGS TO PREVENT STEM LEAKAGE (-40'F to +366 ° F) NEW 2ND GENERATION PTFE MODIFIED SEATS. ONE VALVE IN INVENTORY, ONE VALVE ON THE TRUCK WILL... MEET ALL LOCAL CODEST' AND 366 °F FOR SATURATED STEAM. CSA 125G, UL FOR LIQUID PROPANE, FM LISTED FOR FIRE PROTECTION 150 WSP /600, 500, 400 WOG. T 100N I.P.S 220 -103 S -100N C X C FITS T /S -100N MODEL Iron Pipe SIZES 1/4 ", 3/8 ", & 1/2" Solder ® 220 -104 TYPE 2 FITS T /S -100N MODEL 100 -701 1/4" N/A $5.92 120 12 42 100 -702 3/8" N/A $5.92 120 12 40 100 -703 1/2" 100 -803 $5.92 120 12 64 100 -704 3/4" 100 -804 $8.36 72 12 64 100 -705 1" 100 -805 $12.90 36 6 57 100 -706 1 -1/4" 100 -806 $23.19 24 4 60 100 -707 1 -1/2" 100 -807 $29.55 16 2 52 100 -708 2" 100 -808 $38.86 12 2 61 100 -709 2 -1/2" 100 -809 $120.01 6 2 48 100 -710 3" 100 -810 $176.95 4 2 53 100 -711 4" N/A $308.06 2 1 53 NOTE 1 (3/8" - 3/4" ARE DELTA ztCERTIFIED FOR THE FOOD INDUSTRY) NOTE 2 (1/2" I.P.S. - 2" I.P.S. AGA/CGA CERTIFIED 125 PSI/G 2 -1/2" I.P.S. - 4" I.P.S. AGA TESTED 5 PSI /G) 4 220 -103 TYPE 1 FITS T /S -100N MODEL Iron Pipe SIZES 1/4 ", 3/8 ", & 1/2" $3.83 ® 220 -104 TYPE 2 FITS T /S -100N MODEL 100 -501 t' N/A $13.62 SIZE 3/4" $5.05 41 220 -105 TYPE 3 FITS T /S -100N MODEL $13.62 120 12 40 SIZES V & 1 -1/4" $12.70 100 -513 220 -106 TYPE 4 FITS T /S -100N MODEL 64 100 -504 3/4" 100 -514 SIZES 1 -1/2" & 2" $14.10 12 VALVE NOT INCLUDED IN PRICE 100 -505 FORGED BRASS VALVE WITH 316 STAINLESS STEEL BALL & STEM, VALVE BODY NICKEL PLATED - DOUBLE VITON O -RINGS TO PREVENT STEM LEAKAGE NEW 2ND GENERATION PTFE MODIFIED SEATS. MEETS ALL LOCAL CODES PLUS 366 °F MAXIMUM FOR SATURATED STEAM @ 150 W.S.P. CSA, UL, FM LISTED 150 WSPI600, 500, 400 WOG ( -40 ° F to + 366 ° F) T-100 SS -N I.P.S S -100 SS -N C X C Iron Pipe Solder 100 -501 1/4" N/A $13.62 120 12 41 100 -502 3/8" N/A $13.62 120 12 40 100 -503 1/2" 100 -513 $13.62 120 12 64 100 -504 3/4" 100 -514 $18.24 72 12 65 100 -505 1" 100 -515 $26.82 36 6 51 100 -506 1 -1/4" 100 -516 $40.07 24 4 50 100 -507 1 -1/2" 100 -517 $53.49 16 4 55 100 -508 2" 100 -518 $74.13 12 2 68 100 -509 2 -1/2" 100 -519 $217.34 6 2 67 100 -510 3" 100 -520 $313.40 4 2 69 e 0 ,i A typical turbine model designation has up to five components to define the pump being supplied as follows: STP XXXXX QY -QA -© STP = Basic Model Designation XXXXX = Factory Installed Options STP model designations may include one or more of the following characters in alphabetical order: AG = Alcohol - gasoline compatible (100% ethanol or methanol capable) Note: Standard models 0% to 15% ethanol or methanol capable. F = Floating suction adapter (I -1 /2" NPT female adapter) K = Intake filter screen (IFS, factory installed to PMA) •R = Model R check valve (24 psi relief /22 psi reset for PLLD) •W = Model W check valve (16 psi relief/ 13 psi reset for PPM4000) Note: If not otherwise specified, all STP models supplied with standard model check valve (40 psi relief /35 psi reset for MLD and TS- LS300) FY = Pump MotoR Horsepower Rating 33 = 1/3 hp fixed speed 75 = 3/4 hp fixed speed QA = Model Length - VL I =Variable length range # 1. VL2 = Variable length range #2. VL3 = Variable length range #3. Note: VL2 models fit 94% of all known installations. ©= Riser Pipe Length Riser pipe length is expressed as two numeric characters that indicate the total length of the riser in inches. Riser pipes are available from 7" to 69" in I" increments (additional charge for risers 31" or longer). 1/3 and 3/4 HP Fixed Speed Submersible Turbine Pump Specifications For full diagram see page 5. Power Requirements • 1/3 and 3/4 hp fixed speed models require single - phase, 208 -230 VAC, 60 Hz incoming power. • 1/3 and 3/4 hp fixed speed models incorporate a starting and running capacitor, with internal bleed resistor, rated 370 Volt, 15 microfarad. • STP -SCI single -phase smart controllers and STP -CBS single -phase control boxes are available for 1/3 and 3/4 hp pump control. • 1/3 hp max. motor draw: 4 Amps. • 3/4 hp max. motor draw: 7 Amps. Pump Motor • 1/3 and 3/4 hp fixed speed, 3450 rpm, two -stage centrifugal type pump motor with integral, automatic, thermal overload protection. • 1/3 hp models have a max. flow of 40 gpm and a max. pressure of 28 psi. • 3/4 hp models have a max. flow of 65 gpm and a max, pressure of 31 psi. Liquid Compatibility • Max. liquid viscosity: 70 SSU at 60 °F (15 °C). • Standard models are UL and cUL listed for fuel mixtures containing up to 15% ethanol or methanol, and 20% MTBE, 20% ETBE or 17% TAME with gasoline. • STPAG models are compatible with fuel mixtures containing up to 100% ethanol or methanol, and 20% MTBE, 20% ETBE or 17% TAME with gasoline. • 1/3 and 3/4 hp fixed speed models can also be used with diesel fuels, fuel oils, kerosene, Avgas and jet fuels in a non - gelled pourable state. • All wetted elastomers are made of a high grade, fluorocarbon Viton®• compound. Standard Features • 1/3 and 3/4 hp fixed speed models are available in variable and fixed length options. • Check valve: 2 -3/4" diameter fluorocarbon Viton®' seal constructed on cast aluminum body and steel backing washer. • Pressure relief valve: available in four pressure relief settings, integral to check valve. Standard model relieves at 40 psi and resets above 35 psi. • Syphon: venturi -type syphon primer supplied with every submersible. Syphon check valve and secondary syphon sold separately. • Air eliminator: every submersible includes a tank return path with one -way check valve to provide active air elimination. • Electrical disconnect: electrical yoke for positive contractor disconnect during service. Approvals • Consult factory for applicable approvals. Quality Certification • Franklin Fueling Systems is an ISO 9001 Certified Manufacturer. `Viton® is a registered trademark of DuPont Dow Elastomers. C UL US LISTED 19 1/3 HP High Pressure Fixed Speed Turbine Performance Chart 90 -------------------- -------------------- ----------------------------------------- 80 --- 1 '-- r--- - - -_ -- -- ----------- - - - - -- --------- - - - - -- Two STP33 Manifolded 70 -------- - - - - --- - --- - - - - -` - - -- --------- - -- - -- 1/3 HP Pumps - -- x60 ----------------------- ------ -- -- - - - - -- - - - -` I ---- -- - - - - -- - --- -- ------- - --- -- LL .S 50 --- --- --- - - -- -- - -- - - - - -- --- --- - - - - -- -- -- ----- - - - --- - -- - - -- -- -------------- M b � !g F—° One STP33 1/3 HP Pump 30 - -- - - -- - - --- ------------- - - - - -- -------+------------ 20 ------------------------------------ - -- ------------------- -------------------- 10 -------------------------------------- ------- ------ - - - - -- ----- ------ - - - - ----- ­ 01 1 ` 0 20 40 60 80 Flow in Gallons per Minute (GPM) Note: Performance based on pumping solvent (0.78 specific gravity). Pressure is taken at the manifold discharge outlet STP33 models are powered by a single - phase, 60 Hz, 208/230Volt power supply. 3/4 HP Fixed Speed Turbine Performance Chart 90 80 70 60 0 50 o `0 r 30 20 --- - - - - -- - --- - -- -• — ---- - - - - -- ----------------------------------------------- --------------- - -- --------------- --------------------------------------------- ---- ---- -- -- - - -- --- ----- ---- -- - ---- -- -'- --- ____ -- Two STP75 Manifolded 3/4 HP Pumps ---- - - - - -- -- ----------- - - - ---- ----- - - - - -- One STP75 3/4 HP Pump - -- - -- ----------------------- --- - - - - -- -------------- --------------------------------- ------------ --------------------------------- -- -- - - - - - -- ---- - - - - -- --------- -------------- --- --- - - -- ----------------------- -- -- - - - - -- ---- - -- - -- ----- - -- - -- ------ -- ---- 0 0 20 40 60 80 100 120 Flow in Gallons per Minute (GPM) Note: Performance based on pumping solvent (0.78 specific gravity). Pressure is taken at the manifold discharge outlet STP75 models are powered by a single - phase, 60 Hz, 208/230 Volt power supply. 20 140 c� fl /J I r l r � A R P i i i n 3 1/3 and 3/4 HP Fixed Speed Submersible Turbine Pumps STP33 -VL I Description 1/3 hp fixed speed VLI 55 " -83" STP33 -VL2 1/3 hp fixed speed :1 86" -147" STP33 -VL3 a - 1 18" -209" o 3/4 hp fixed speed " 5T' -86" STP75 -VL2 314 hp fixed speed VL2 88"-149" STP75 -VL3 --------------------- -- J, STPAG33-VLI 3/4 hp fixed speed Description 1/3 hp AG fixed speed VL3 Model Length Range Number I VLI 120" -212" 55 " -83" i i i n 3 1/3 and 3/4 HP Fixed Speed Submersible Turbine Pumps STP33 -VL I Description 1/3 hp fixed speed VLI 55 " -83" STP33 -VL2 1/3 hp fixed speed VL2 86" -147" STP33 -VL3 1/3 hp fixed speed VU 1 18" -209" STP75 -VLI 3/4 hp fixed speed VLI 5T' -86" STP75 -VL2 314 hp fixed speed VL2 88"-149" STP75 -VL3 --------------------- -- J, STPAG33-VLI 3/4 hp fixed speed Description 1/3 hp AG fixed speed VL3 Model Length Range Number I VLI 120" -212" 55 " -83" STPAG33 -VL2 1/3 hp AG fixed speed VL2 86"-147" STPAG33 -VL3 1/3 hp AG fixed speed VL3 118"-209" STPAG75 -VLI 3/4 hp AG fixed speed VLI 57 " -86" STPAG75 -VL2 3/4 hp AG fixed speed VL2 88" -149" STPAG75 -VL3 3/4 hp AG fixed speed VU 120 " -212" Notes: I. STP models are compatible with fuel mixtures containing: up to 15% ethanol or methanol with gasoline, and 20% MTBE, 20% ETBE or 17% TAME with gasoline. STPAG models are compatible with fuel mixtures containing: up to 100% ethanol or methanol with gasoline, and 20% MTBE, 20% ETBE or 17% TAME with gasoline. 2. All models are supplied with a standard check valve unless factory option "R" or "W" is specified. 3. All above models require single- phase, 208 -230 VAC, 60 Hz incoming power. 4.4" riser pipe, if supplied locally, must be 4 -1/2" OD by 3/16" WT tubing. 5. For riser pipe lengths 31" to 69 ", adder charge applies. 'Model length (A) defined as the dimension from turbine manifold bottom to pump motor inlet. Factory Installed Options (specified in model number at time of STP order) .- Field Installed Options (1/3 and 3/4 hp fixed speed specific accessories) Part Number Description F Floating suction adapter, 1 -1/2" NPT female, must be factory installed K IFS (intake filter screen), factory assembled to pump motor assembly R Model R check valve, factory installed, for Veeder -Root PLLD Line Leak W Model W check valve, factory installed, for Red Jacket PPM4000 Line Leak Field Installed Options (1/3 and 3/4 hp fixed speed specific accessories) Part Number Description 400137908 Syphon check valve, alcohol - gasoline compatible (when ordered with STP) 400818921 STP -CBS, single -phase control box with lockout switch, 110 Volt coil 402312921 STP -DHI -SCI, combo DHI with factory wired STP -SCI (when purchased with a 4" STP) 1402312921 STP -DHI -SCI, combo DHI with factory wired STP -SCI (when purchased without a 4" STP)' 402313921 STP -DHI -CBS, combo DHI with factory wired STP -CBS 402459931 Model 65 psi check valve (for slave of manifolded STPs with Veeder -Root PLLD) 402507930 Secondary syphon kit (when two syphon primes are required for one STP) 5800 1 002 1 5 STP -SCI, single -phase smart controller when purchased without a 4" STP) 5800100215 STP -SCI, single -phase smart controller (when purchased with a 4" STP)' 5800300100 STP -DHI, dispenser hook isolation for I I OVolt dispenser handle switches, up to eight each When purchasing STP -SCI or STP - DHI -SCI in equal quantities of fixed speed 4" STPs, the STP -SCI or STP -DHI -SCI will be invoiced at special discount pricing. 21 ITEM #14 EtlBadger Meter Europa GmbH LMS Baby System Costco Additive Dispensing System l OPERATIONS MANUAL June 2011 Firmware v5.05 o ®® 0000 O17® O STOP l OPERATIONS MANUAL June 2011 Firmware v5.05 Contents ITEM #14 1. Basic safety recommendations ............................................................. ............................... 1 2. General description ................................................................................. ............................... 2 2.1 Technical data ............................................................................................. ............................... 2 2.2 Front plate description ................................................................................. ............................... 3 3. Dispense procedure ................................................................................ ............................... 4 3.1 Abnormal Stops ............................................................................................. ..............................5 4. Installer menu: ....................................................................................................................... 5 5. General system reset .............................................................................. ............................... 9 6. Dispense timing ..................................................................................... ............................... 10 7. Printer ..................................................................................................... ............................... 10 7.1 Internal ticket printer .................................................................................. ............................... 10 8. Manufacturer's declaration .................................................................. ............................... 11 9. Warranty ................................................................................................. ............................... 12 10. DIN ISO certificate ............................................................................... ............................... 12 11. Technical Support .................................... ............................... ...........................Back Cover Basic safety recommendations 1. Basic safety recommendations. JITEM #14 Pa Before installing or using this product, please read this instruction manual thoroughly. Only qualified personnel should install and /or repair this product. If a fault appears, contact your distributor. Installation Do not place any unit on an unstable surface that may allow it to fall. Never place the units above a radiator or heating unit. Route all cabling away from potential hazards. Isolate from the mains before removing any covers. Power connection Use only the type of power source suitable for electronic equipment. If in doubt, contact your distributor. Ensure that any power cables are of a sufficiently high current rating. All units must be earthed to eliminate risk of electric shock. Failure to properly earth a unit may cause damage to that unit or data stored within it. Protection class The device has protection class IP 42 and needs to be protected against dripping water, water, oils, etc. Setup & operation Adjust only those controls that are covered by the operating instructions. Improper adjustment of other controls may result in damage, incorrect operation or loss of data. Cleaning Switch off all units and isolate from mains before cleaning. Clean using a damp cloth. Do not use liquid or aerosol cleaners. Repair of faults Disconnect all units from power supply and have it repaired by a qualified service person if any of the following occurs: If any power cord or plug is damaged or frayed If a unit does not operate normally when operating instructions are followed If a unit exposed to rainwater or if any liquid has been spilled into it • If a unit has been dropped or damaged • If a unit shows a change in performance, indicating a need for service. Failure to adhere to these safety instructions may result in damage to the product or serious bodily injury. Rolls Our products are RoHs compliant. Battery disposal The batteries contained in our products need to be disposed of as per your local legislation acc. to EU directive 2006/66/EG. r LMS_Baby System General description ITEM #14 Page 2. General description 2.1 Technical data CPU: Atmel, AT103, 8 -bit, serial flash, 128 K bytes of In —System programmable flash Memory: Flash, 1 Mbit Firmware update: With special serial adapter Interfaces: 1x 25 -pole RS232 port to be used as printer or PC connection Baudrate 9600 - Parity none - Databits 8, Linefeed LF /CR Fuses F1 = Fuse controller 1.00 AmT F2 = Fuse I / O 3.15 AmT F3 = Fuse printer 6.30 AmT Signal Input NPN opto isolated Relais load 2A at 250VAC or 30 VDC Transactions 2999 max. User 99 max. Power 1/O Pulse input Valve control CPU Display Keypad Internal printer Interfaces External printer Interface flash LMS Bab _ Y System p� y , . � \ d � �' � ~. � )� . z �. . 3 � . |��. <� �Kg . � : �I. , �� I . � \/�/ `. /� � } � \ ` d :\ \ Dispense procedure 3. Dispense procedure ITEM #14 Pa e 4712 R3 LMS Bab _ Y System Enter the Purchase Order number of the fuel delivery. Up to 15 digits maybe entered. (Or enter 4 -digit Installer PIN number to Gas Delivery PO# * * * * * * * * * * * * * * ** enter administrative menus). Press "OK" 123456789012345 • Enter the number of the Tank into which the fuel will be Dispense to: delivered. (Or use arrows to move through the list). Tankl 1 Tank2 2 Tank3 3 Press "OK" Inactive 4 Enter the number of gallons of fuel that will be delivered. Delivered (Maximum amount is 16,000 gallons). Quantity of fuel Press "OK" 8700 Gal Additive quantity will be calculated automatically. Calc.Quantity of additive: Press "OK" to start pump. 2.86 Gal Display will indicate "Ready to Dispense" for a period of time Ready before the valve opens to begin the dispense. (This delay is to programmable from 0 to 255 seconds). dispense 00002.86 Gal • When the dispense begins, the display will increment until the calculated amount of additive has been dispensed. 000.00 00002.86 Gal Ticket printout Ticket will print out automatically after completion of the dispense. 03 -10 -11 15:31 U1trzl9888C PO# 1234567890123 Fuel Gal 8700 Tankl 1 Gal 000002.86 R3 LMS Bab _ Y System Installer menu: PIN XXXX (default) 3.1 Abnormal Stops The batch will stop when : OSTOP - Button No flow detected, the attached valve has been closed manually. Can be adjusted in menu "Inactive Timeout ". The max. dispense quantity has been reached. Can be adjusted in menu "Max. Dispense ". 4. Installer menu: PIN XXXX (default) Products I This feature will rarely be used. Changes the name of the Tank. For example, can be used to change "Inactive" to Tank4. Select a "Product" (1 through 4) and confirm with "OK" or return with "Quit". Enter the new name and confirm with "OK" or return with "Quit". LMS_Baby System PalITEM #14 .,- — . - Select Product: Tankl 1 Tank2 2 Tank3 3 Inactive 4 Input new Product name: Tankl 1 immamolmi ITEM #14 Installer menu: PIN XXXX (default) Page Set Min Stock This feature is not used on the Costco Additive Select Product: Dispensing System. Tankl 1 Tank2 2 Default value is 000000.00 GAL Tank3 3 Inactive 9 Changing the default value will result in unwanted k==Emli stock level warnings. Input Minimum Stocklevel: Tank 1 1 000200.00 GAL Set Mode Operation mode should be set to "Pre - Select" for Select Product: all tanks. This parameter should not be changed. Tankl 1 The parameter must be set for EACH tank. Tank2 2 Tank3 3 Inactive 4 kzEME=1zi --------------- -- Operation Mode 1 --------------- -- Pre- select 1 Free Dispense 2 • • Initial Theout Defines the delay between the pump start and the valve actuation to begin the dispense. Default is Select Product: Tankl 1 20 seconds to allow the leak detector (not part of Tank2 2 this system) to obtain a stable reading. The time Tank3 3 must be set for EACH tank. Inactive 4 Select a product and confirm with "Or ----------------- or return with °Quit°. Timeout: 020 Enter the new timeout and confirm with "Or ----------------- or return with "Quit°. in fromeconds 0 -255 kMENEEMBIC Inactive Timeout If the pulse input from the meter stops before the preselected quantity has been reached, the Select Product: Tankl 1 system will wait for the defined time before the Tank2 2 batch stops and the valve closes (default 6 sec). Tank3 3 This will not occur during normal operation. The Inactive 4 timeout must be set for EACH tank. Select a Tank and confirm with "Or or return with °QUIT. ----------------- Timeout: 006 Enter the new timout and confirm with "Or --------------- -- in Seconds from 0 -255 or return with "Quit. AB LMS Bab _ Y System Installer Menu Page Install PIN PIN XXXX can be changed "Error" is displayed if the entered PIN number Input new PIN has already been allocated to another operator. Installer PIN: XXXX Enter the PIN number and confirm with "OK" or return with "Quit". • • Hose Calibration Calibration or scale factor for each hose (meter). CF= (Flowmeter K- 1001x- factor. For example, forflowmeter with K- factor of 251 Select Product: Tankl 1 pulsestgallon, CF = 100/251 = 0.3984. Enter without decimal factor) point as: Tank2 2 Tank3 3 CF:03984 Inactive 4 Select a Tank and confirm with "OK" or return with 'Quit°. Enter the calibration factor and confirm with 'OK" --------------- -- CF: 0 3 9 8 4 or return with 'Quit". ----------------- Cal.Constant 0.000001L /Puls Ignore the "Cal Constant" below the CF. THE SAME CF MUST BE ENTERED FOR EACH TANK " Hose Offset Can correct for over delivery caused by a slowvalve. The (Tank Offset) Calibration Offset (CO)isin tenths ofgallons. For example, if Select Product: system is delivering 2.91 gallons when calculated amount is Tankl 1 2.88 gallons, an offset of 0.05 gallons is entered as: Tank2 2 Tank3 3 CO: 050000 Inactive 4 In this example, the system will close the valve when the dispensed volume reaches 2.82 gallons. The overrun due to the slow valve will result in the correct dispense of 2.87 _______ gallons. CO: 000000 Select a Tank and confirm with 'OK" --------------- -- Cali .Offset or return with 'Quit". (0.000001L) Enter the hose offset (CO) and confirm with 'OK" or return with "Quit". "THE CO MUST BE ENTERED FOR EACH TANK" Print Parameter Will print the current configuration on the specified printer No sub menu. for each Tank. Setup Printer Printer selection 0: No printer assigned Printer: 1 -------- - - - - -o 1: Internal printer 2: External printer non 3: Internal and external printer Internal 1 External 2 Int.& Ext. 3 =globs 0 A3LMS_Baby System Installer Menu ITEM #14 Page 8/12 Clear Deletes all stored transactions. The system stores up to 2999 Transactions transactions. - - - - -- ! ! ! W----- !!! WARNING !!! --------------- -- Proceeding will delete all saved transactions Hose Linkage Defines which hose (meter) will be linked to a Select Product: certain stock (tank). The default settings are 1 -1, Tankl 1 2 -2, 3 -3, and 4 -4. Tank2 2 Tank3 3 THESE SETTINGS SHOULD NOT BE Inactive 4 CHANGED Select a product and confirm with "OK" LINKAGE or return with "Quit". Hose 1 --------------- -- Stock 1 Enter the hose linkage and confirm with "OK" or return with "Quit'. kZMEN0011i Inactive Delay Defines the delay between the end of the Select Product: dispense (valve closed) and the turn -off of the Tankl 1 pump. Default setting is 10 seconds. Tank2 2 Tank3 3 Inactive 4 Select a Tank and confirm with "OK" or return with "Quit'. • • ----------------- Enter the delay and confirm with "OK" or return with "Quit". Stp. Delay: 010 --------------- -- Stop Delay in THE DELAY MUST BE ENTERED FOR EACH TANK " Seconds 0 -255 • • Scaling Unit Unit can be selected. Default is 3 (gallons). Select Product: Tankl 1 Unit: 0: Liter 1`.kg 2:m3 3:Gal Tank2 2 Tank3 3 Inactive 4 Select a Tank and confirm with "OK", or return with "Quit". . . Enter the unit and confirm with "OK ", or return with "Quit'. ----------------- Scal.Unit: 3 "THE UNIT MUST BE ENTERED FOR EACH --------------- -- TANK'* 0 : Liter 1 : kg 2:m3 3:Gal • • Special Mode The Special Mode must be set to 2 (Additive Special Mode: 0 Calc) for the Costco system. --------------- -- Standard 0 Direct Mode 1 Additive Calc 2 .�3 LMS_Baby System ITEM #14 Installer Menu scanner Not Used. Must be set to 0 (Disabled). Scanner: 0 --------------- -- Disabled 0 Enabled 1 immman"- Additive Enter the treat rate for the additive. For example, Product: (Treat Raba) 329 PPM x 8700 gallons of fuel = 2.86 gallons of Tank 1 1 additive. Factor: 000329 (ppm) Select a Tank and confirm with "OK" or return with "Quit". • • Enter the treat rate and confirm with "OK" or return with "Quit". ppm = Parts per Million **** THE TREAT RATE MUST BE ENTERED FOR EACH TANK **** Max. Dispense The maximum possible dispense. Default is 6 gallons. Free Mode Max.Dispense 000006.00 (4200.00) 5. General system reset This function will reset and erase the LMS Baby System (only firmware v3.9.) Note: All data have to be entered again! Procedure: Unplug the LMS Baby and press the buttons 1 and 2. Keep the buttons pressed and plug in the power supply. !!! CAUTION !!! This procedure will erase and reset the device ARE YOU SURE ? Quit: Cancel OK: Proceed ARE YOU SURE ? Quit: Cancel OK: Proceed xxxx of 2126 LMS—Baby System Dispense Timing and Printer 6. Dispense timing Master Valve or Pump Control will be active if there is an on -going dispense. ITEM #14 Page Relay closed I I MasterValve or I I PumpControl I I I I Connection I I Potential free relay aw- Relay closed i----------- - - - - -i On -going Dispense I Hose 1, 2, 3, 4 to Solenoid Valve I I I I Connection 4 (5,6,7) Relay activates 24VDC t Initial Timeout Inactive Delay Dispense See configuration (page 6) Dlspense See configuration (page 8) Start Delay can be adjusted from 0 -255s Stopped Delay can be adjusted from 0 -255s For each additive separate For each additive separate Default Is 20 sec Default Is 10 sec 7. Printer 7.1 Internal ticket printer To change the paper roll, please proceed as follows: • Open the printer cover and press down "Push ". • Insert the end of the paper roll in the slit of the print mechanism and position the paper roll so that it rotates in the right direction, as shown below. • The paper is automatically pulled by the roller for 3 or 4 cm. • Tear off the paper and re -close the cover. WARNING! Make sure the paper edge is straight before inserting it in the machine. 07 LMS —Baby System ITEM #14 Winufacturer's declaration 8. Manufacturer's declaration Herstellererklarung Manufacturers Declaration Badger Meter Europa Bauart Typ Managementsystem for Aossigkeften Model Type Management System for fluids• Typenbezeichnung MDS -2000, LMS -RF, LMS -Baby Model Name MOS -2000, LMS -RF LMS -Baby Seriennummer Nach' Komponenten gelistet Serial Number lrstet by components Baujahr ab 1997 Construction year from 1997 Referem 1 Reference: Maschinen Richtlinien Machine Directives untediegt nicht dem Anwendungsbereich von 2006 /42/EG nach Artikel 1 isn't subjected to the application area of 20061421EG acc. to 1 CE- Richtlinien Elektrische Betriebsmittel Electrical Device Directives 2006/95/EG 93/68 /EEC Hiermit bestatigen wir die Obereinstimmung unserer Gerate mit den o.g. Richtlinien. Vor Inbetriebnahme der oben genannten Gerate muss sichergestellt sein, dass die Gesamtenlage bzw. Maschine, in der die Gerate verwendet werden, den gehenden Richtlinien and Bestimmungen entspricht. We herewith confirm that our products are in accordance with above mentioned directives. The equipment identAed above must not be put into service until the mechinery into which it is to be incorporated has been dac/aied in conformity with the provrslons of above directives. 09.06.2010 =escm Ume rxhrih l Sigma eneral M anager Qualitptsrta nagemem / Quality Manager Horst Gras. Eberhard Wannenwetsch OM_MOS•ff .CE d_e_107.doc 08110 Badger Meter Europa GmbH - NOrtinger Strasse.76 - 32639 Neuffen (Germany), Tel. +49 7025 - 9208 -0: Fax +497025. 9208 -15 www.badgermeter.de E- mail:badger @badgermeter.de R3 LMS_Baby System a. 8 �i a s J Ey 8 IFT7 Warranty/ DIN ISO certificate I ITEM 414 9. Warranty Badger Meter warrants meters and parts manufactured by it and supplied hereunder to be free from defects in materials and workmanship for a period of 12 months from date of shipment. If within such period any meters or parts shall be proved to Seller's satisfaction to be defective, such meters or parts shall be repaired or replaced at Seller's option. Seller's obligation hereunder shall be limited to such repair and replacement and shall be conditioned upon Seller's receiving written notice of any alleged defect within 10 days after its discovery and, at Seller's option, return of such meters or parts to Seller, f.o.b. its factory. THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS OR IMPLIED WARRANTIES WHATSOEVER INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES (EXCEPT OF TITLE) OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Badger Meter shall not be liable for any defects attributable to acts or omissions of others after shipment, nor any consequential, incidental or contingent damage whatsoever. 10. DIN ISO certificate CERTIFICATE Tho cenlneanen easy of TOV SOD Management Servke GmbH ceNries tw Badger Meter Europa OmbH NOrlinger 3trasse 76 0-72839 NeuHen has esieb0ahed and epplbs a Ouardy Management system for Flowmetertng and Control. Design, Satnng and Production. M audit was performed, Report No. 70002916 Proof has been furnished that the requirements according to ISO 9001: 2000 are WNW. The owtificate Is valid until 2011-02-13 Cenificate Registration No. 12100 24974 TMS �. r uua,axsm.ro msia..arnn tpvS0ac4urpxalmtc• achtl• IrtflAcnbL •IBWrmca•65•IaOIYOxhn•bmuy 70VO R3LMS_Baby System ITEM #14 Technical Support Please contact your supplier for any assistance you may need. X• FLOW MEASUREMENT • U.S Division: Cox Flow Measurement Tel: 480 - 948 -3789 www.coxflow.com A Division of Badger Meter U.S. Distributor: ANS Distributing Tel: 602 - 278 -3000 www.ansdistributing.com Badger Meter Europa GmbH Subsidiary of Badger Meter, Inc. NOrtinger Strasse 76 72639 Neuffen (Germany) ® E -Mail: badger @badgermeter.de www.badgermeter.de SPECIFICATION OPTIONS: FIG. NUMBER A B C WEIGH 184 -- -0120113 1.25 "xixi Cl N/A 0.5 184 -- -0120 113 1.25 "x 1x 1 CI N/A 0.5 184 -- -0000 1 B 1.5"x.75 x.75 CI N/A 0.75 184 -- -010016 2" x 3/8 x 3/8 Cl N/A 0.75 184 - - -0110 113 1.5 "x 1/2 x 1/2 CI N/A 0.75 184 - - -0130 113 1.5 "x 1 x 1 CI WA 0.75 184 -- -0200 1 B 2" x.5 x.5 CI N/A 0.75 184 -- -0300 1 B 2" x .75 x .75 CI N/A 0.75 184 - - -0400 1 B 2"x 1 x 1 Cl N/A 1 184 -- -0600 1 B 2" x 1.5 x 1.5 Cl j NA 0.75 - -080 2.5"x 1.25 x .25 184 -- -0900 1 B 2.5"x 1.5 x 1.5 Cl N/A 1.25 184 -- -1000 113 2.5" x 2 x 2 CI N/A 1.25 184 -- -1100 113 3" x 1 x 1 Cl N/A 1.5 184 -- -1200 1 B 3" x 1.25 x 1.25 Cl N/A 2 184 -- -1300 1 B 3" x 1.5 x 1.5 Cl N/A 2 184 -- -1400 MB 3" x2 x 2 Cl N/A 2 184 -- -1500 1 B 3" x 2.5 x 2.5 S WA 2 184 -- -1800 1 B 3.5"x 1.5 x 1.5 Cl N/A 2.25 184 -- -1900 1 B 3.5" x 2 x 2 Cl WA 2.5 184 -- -2100 113 3.5" x 3 x 3 S N/A 2.25 184 -- -2200 1 B 4"x 1 x 1 Cl N/A 3.75 184 -- -2300 1 B 4" x 1.25 x 1.25 Cl N/A 4.9 184 -- -2400 1 B 4" x 1.5 x 1.5 Cl N/A 2.5 184 -- -2500 MB 4"x 2 x 2 Cl N/A 2.5 184 -- -2600 1 B 4" x 2.5 x 2.5 CI N/A 4.25 184 -- -2700 1 B 4" x 3 x 3 Cl N/A 3.4 184 -- -2900 1 B 6" x 4 x 4 CI N/A 8 184 -- -2900 1 P 6" Pipe Plug CI WA 2.95 184- --3000 1 P 4" Pipe Plug Cl WA 1.5 184 -- -3100 1P 3" Pipe Plug Cl WA 3 184 -- -3200 1 P 2" Pipe Plug Cl WA 2.75 184 -- -3400 1 P 1" Pipe Plug Cl WA 0.25 184- --3500 1 P .75" Pipe Plug Cl N/A 0.15 18413- -0100 1 B 2" x 3/8 x 3/8 CI Y 12oz 184D - -0200 1 B 2" x .5 x .5 Cl Y 110z 184D - -0300 AB 4 "x.75 "x.75" CI Y WA 184D- -0301 MB I 4 "x.75 "x.75" CI N WA 184D --0401 MB I 4 "x.1 "x.1" CI N WA Fig. 184 Double Tapped Bushings Double Tapped Bushings are used in pipe and tank fitting to reduce or adapt to a connection. Double Tapped Bushing Fig. 184D Duplex Bushings The Duplex Bushings are used to convert a single tank opening to dual threaded openings. One opening is single tapped and the other is double tapped. Duplex Bushing CHART KEY: A -Size: Male NPT x Female NPT x Female NPT 13--Cast Iron (CI), Steel (S) C -Brass Tubing Connectors: Yes (Y), No (N), Not Applicable (N /A) Weight - Shipping Weight LAMorrison Bros. Co. P.O. Box 238 • Dubuque, Iowa 52004 -0238 563.583.5701 (tel) • 800.553.4840.563.583.5028 (fax) Established 1855 www.morbros.com Description — FLEX -ING's premiere above and below ground fire rated flex connector. �s.. gg• Application — Connects the shear valve with primary piping in a fuel dispenser sump system. Features — Successful Praxair/Tracer Testing • All metal construction means one flex- connector for both above and below ground applications. Testable under full vacuum. • • UL Listed for above and below ground installation. • An 18 -8 alloy with titanium, 321 Stainless Steel inner core provides a long service life. • Standard wall thickness with close pitch corrugations gives more flexibility. • - The 346 Integral Male Swivel* ensures ease of installation with a multi -seal design. • - : Thick, schedule 80 hex end fittings protect against deformation • of the ends. - • 100% pressure tested to assure quality. • 350 psi working pressure assembly exceeds UL 50 psi • requirement on 3/4" - 3 ". 225 psi on 4" Minimum Bend Radius from Centerline of Hose 6" - Hose up to 2" 9" - Hose up to 3" 13" - Hose up to 4" COT NFAN MEMBER 2009 -2010 See Requirements and Installation Instructions on Page 2 U` Requirements — • Must be used in a liquid tight sump • Must be used with operational leak detection • Must not come in contact with Brine, Saltwater, Saltwater splash, saltwater spray and /or chlorine • You must visually inspect the flex connector for any defect or damage that may have occurred during shipping • If you find a damaged flex connector, you must return it to FLEX -ING or the authorized distributor • Flex connectors must be replaced when the dispenser has been hit or disrupted • Replace the flex connector if the shear valve has broken. Shear valve must remain properly mounted • Tags are an integral part of the connector and must remain intact • Do not remove tags or labels • Never coat a flex connector with a non - approved coating • Do Not torque flex connector • Install in one plane of motion • Do Not exceed minimum bend radius • Do Not compress or deform • You must be OSHA trained and have OSHA approved equipment Installation Instructions — DO NOT COMPRESS OR EXTEND AXIALLY PROVIDE SUPPORT Corrugated metal hose installed in -line with the longitudinal When installing the assembly in a horizontal axis of the piping should not be subject to axial movement. loop, provide support for the arms to prevent the hose from sagging. correct Wmn SIM Un AVOID SHARP BENDS Use elbows to avoid sharp bends near the end of the metal hose assembly. �i DO NOT ALLOW MOVEMENT IN MULTIPLE PLANES Flexing a metal hose in two separate planes of movement will torque the hose assembly. Always install the metal hose assembly so that flexing occurs in one plane only, the plane in which bending occurs. 1� =Ji co.race In plan0 n•.Ino I I w.onp oua o1 plwna neano Correa .apps. Wrong L,PPO.. s.o•�ro r.a IurP 4rW MAINTAIN MINIMUM CENTERLINE BEND RADIUS Flex connectors must be used in a liquid tight sump with operational leak detection. 1 tared �I DO NOT TORQUE DURING INSTALLATION Do not use to compensate for bolt hole misalign- ment. Floating flanges will help to minimize twisting of the metal hose. Pipe unions will help to reduce twisting during connection to the piping. The use of two wrenches will help to keep the hose from twisting when tightening the pipe union. Correct Wrong in plane out of plane flexing flexing Installation Instruction Tags are an integral part of the flex connector. If you receive a Flex- connector without an installation tag contact us immediately at 1- 800 - 333 -3599. Removal of this tag voids the warranty and the LIL Listing. All metal hose assemblies are custom made. We do have standard catalog products but they are considered non - stock. All returns require a Return Goods Authorization number and a re- stocking charge will be applied. Some products may be non - returnable. i BRAVO SYSTEMS AST r�° ..v.oncreie BRAVO SYSTEMS N W H N N U fY J Z 0 P a 0 13500 Model features an epoxy powder- coated Steel lid with handles Penetrations sold separately PIPE SHOWN FOR ILLUSTRATIVE PURPOSES ONLY IT 0 N r. 55" L 38.5 L 22.5" W 22:5" W �. 33 " -48" D 33 "-48 D 8500 -5L 8500 -3S up to 6 fittings up .to, 3 fittings - S. BRAVO SYSTEMS, INC • 2929 Vail Avenue - Commerce • CA - 90040 Fax: 323/888 -4123 • E -mail: info @sbravo.com • http: / /www.sbravo.com o� 0 .i cn1 a PE1 I j M EM MENT B- 500 -TS `08 Optional RS -500 Rack System is Fully Adjustable 36" - 96" Height N r CM N J J Q Z O z a- 0 N r. 55" L 38.5 L 22.5" W 22:5" W �. 33 " -48" D 33 "-48 D 8500 -5L 8500 -3S up to 6 fittings up .to, 3 fittings - S. BRAVO SYSTEMS, INC • 2929 Vail Avenue - Commerce • CA - 90040 Fax: 323/888 -4123 • E -mail: info @sbravo.com • http: / /www.sbravo.com o� 0 .i cn1 a PE1 I j M EM MENT B- 500 -TS `08 F /LaXW R KS BY OPW FUELING CONTAINMENT BYBTEMB Automatic Fire Extinguisher System The FlexWorks Automatic Fire Extinguisher System is a small, non - rechargeable fire extinguisher designed specifically to be installed in a containment sump underneath an above - ground fuel dispenser, and to automatically extinguish a fuel fire in the event of a dispenser knock -over. The FlexWorks Fire Extinguisher System will automatically activate and discharge its extinguishing agent when the surrounding temperature reaches 175 °F (79 °C). The Fire Extinguisher comes with it's own mounting bracket and can be mounted to a variety of surfaces. The Fire Extinguisher contains enough extinguishing agent to protect dispenser containment sumps up to a maximum capacity of 50 cubic feet. O P WA* A COMNRNI North Amerka Toll Free - TELEPHONE: (800) 422.2525 Fax: (800) 421 -3297 • Email: domestksales@opw- fc.com Intemd1onal - TELEPHONE: (513) 870-3315 or (513) 870.3261 Fax: (513) 870.3157 • Email: InOsales@opw- fc.com • www.opw4c.= 9393 Princeton-Glendale Road • Han tton, OH 45011 0 ® 2009 OPW Fueling Components ONE COMPANY. ONE WORLQ ONE SOURCE.' Features • Charged with a clean agent — FE -241 • Operating temperatures of 0°F to 130 °F • One year replacement warranty • Low cost solution to a potentially expensive problem Benefits • Extinguishes fuel fires quickly • Provides year -round fire protection • No certified annual testing required • May reduce fire insurance premiums ITEM #20 Fire Prevention Dispenser and UST containment sumps offer significant environmental protection by providing secondary containment and corrosion protection of valves and pipe fittings. Under certain conditions, a potential fire hazard could develop. Should a fire occur inside the containment chamber, the FlexWorks Automatic Fire Extinguisher System automatically extinguishes the fire in a matter of seconds protecting patrons, the underground piping, shear valves, and sump. Application Dispenser Containment Sump Agent FE-241 Coverage Area: 50 Cu. Ft. Atmospheric Life Less than one day Activation Temp: 175 °F (79 °C) Operating Temp Range: 0 °F to 130 °F (17.7 °C to 54.4 °C) Ordering Specifications FlexWorks Automatic Fire Extinguisher System Model Description FSS•50 I FlexWorks Automatic Fire Extinguisher System The complete Environmental System for underground fuel transfer and containment for the 21st century. 2" FULL NPT FTG`. on 8" RADIU (2 TYP 6" NPT FTG. W/4 DOUBLE TAP BUSHIN on 6-1/2" RADIU (24) 5 /8 "dia.BOLT HOLES )LT HOLE CIRCLE " NPT FTG. on 8" RADIUS 1 1/4" 1/4" q m K w 22 MANWAY LID CONTAINMENT DRAWN BY: DATE: DWG : SOLUTIONS KAS 8/13/12 M22- 22F146H ASViS Rediag Features • 2 -way normally closed operation • For control of commercial and industrial gas burners • Ideal for high pressure applications • Brass body construction • Mountable in any position Fluid Fuel Gas Construction Valve Parts in Contact with Fluids Body Brass Seals and Disc NBR Core Tube 305 Stainless Steel Core and Plugnut 430F Stainless Steel Springs 302 Stainless Steel Shading Coil Copper Electrical Solenoid Enclosures Standard: Watertight, Types 1, 2, 3, 3S, 4, and 4X with 1/2° conduit hub. Optional: RedHat II - Explosionproof and Watertight. To order, add Prefix "EF" to catalog numbers. (e.g. EF8210G075) Valve Response Time Opening Time: Less than 1 second Closing Time: Less than 1 second Pilot Operated Gas Shutoff Valves 3/8" to 3/4" NPT 2/2 SERIES 8210 C us ► 1NfiE _. Approvals UL listed to standard 429 "Electrically Operated Valves," Guide YIOZ, File MP618, Safety Valves. FM Approved to Class 7400 "Liquid and Gas Safety Shutoff Valves." CSA Certified to: 1) Standard C22.2 No. 139 "Electrically Operated Valves," File 010381 2) Automatic Gas Valves Z21.21 (6.5), File 112872. 8210 NCR1 321 Watt Rating and Power Consumption Spare Coil Family Standard AC General Purpose Exploslonproof Coll and VA VA Class of Ambient Insulation Watts Holding Inrush Temp. °F AC AC F 1 10.1 25 13210 125 1 238610 238614 F 110.1 25 70 132 to 140 1 238810 238914 Standard Voltages: 24, 120, 240 volts AC, 60 Hz (or 110, 220 volts AC, 50 Hz). Optional High Ambient Temp: 140 °F Class H coil with prefix HT. Solenoid Enclosures Standard: Watertight, Types 1, 2, 3, 3S, 4, and 4X with 1/2° conduit hub. Optional: RedHat II - Explosionproof and Watertight. To order, add Prefix "EF" to catalog numbers. (e.g. EF8210G075) Valve Response Time Opening Time: Less than 1 second Closing Time: Less than 1 second Pilot Operated Gas Shutoff Valves 3/8" to 3/4" NPT 2/2 SERIES 8210 C us ► 1NfiE _. Approvals UL listed to standard 429 "Electrically Operated Valves," Guide YIOZ, File MP618, Safety Valves. FM Approved to Class 7400 "Liquid and Gas Safety Shutoff Valves." CSA Certified to: 1) Standard C22.2 No. 139 "Electrically Operated Valves," File 010381 2) Automatic Gas Valves Z21.21 (6.5), File 112872. 8210 NCR1 321 2/2 SERIES 8210 Specifications (English units) ITEM #39 ASVisa Pipe Size (Ins.) Orifice Size (Ins.) Cv Flow Factor Gas i Capacity O Operating Pressure i Differential (psi) Max. FIUId Temp. °F Catalog Number Const. Ref. Agency Wattage Approx. Shipping Weight (Ibs) Btu/hr. Min. I Max. UL FM CSA COMBUSTION. (Fuel Gas) - NORMALLY CLOSED 3/8 5/8 2.8 150,000 0 50 125 8210GO74 1 O O O 10.1 3.2 1/2 5/8 3.6 193,000 0 50 125 8210GO75 1 O O O 10.1 3.2 3/4 3/4 1 5.0 295,000 0 50 125 8210GO76 2 O O O 10.1 3.4 O = Safety Shutoff Valve. O 1' W.C. Drop ® 2' W.C. Inlet Pressure, 1,000 Btu /cu.ft. or more, 0.64 Specific Gravity Gas. Specifications (Metric units) Pipe Size (Ins.) Orifice Size (mm) Kv Flow Wthr) Gas Capacity O Operating Pressure Differential (bar) I Max. Fluid Temp `C Catalog Number CenSt. Ret. Agency Wattage Approx. Shipping Weight (kgs) Btu/hr. Min. Max. UL FM I CSA COMBUSTION (Fuel Gas) - NORMALLY CLOSED 3/8 16 2.4 150,000 0 3.4 52 8210GO74 1 O O O 10.1 1.5 1/2 16 3.1 193,000 0 3.4 52 8210GO75 1 O O O 10.1 1.5 3/4 16 1 4.3 295,000 0 3.4 52 8210GO76 2 O O O 10.1 1.5 O = Safety Shutoff Valve. O 1' W.C. Drop @ 2" W.C. Inlet Pressure, 1,000 Btu /cu.ft. or more, 0.64 Specific Gravity Gas. Capabilities Chart - Solenoid Options Base Catalog Number Resilient Materials Standard Rebuild Kit NEMA Type 3 -9 High Temp. T Junction Box Wiring Box Screw Terminal Brass NBR AC EF HT JB JKF 8210GO74 • 304076 EF HT JB JKF 8210GO75 • 304076 EF HT JB JKF 8210GO76 • 304076 • = Standard. Other options may be available. All option combinations may not be available. Dimensions inches (mm) Censt. Ref. A B H J K L N P T W Ins. 1.66 3.03 3.95 2.04 2.42 2.75 3.42 3.39 1.95 2.28 1 mm 42 77 100 52 61 70 87 86 50 58 Const. Ref. 1, 2 2 ins. mm 2.2 1.66 3.03 4.20 2.04 2.58 2.81 3.45 3.55 1.95 8 42 77 107 52 66 71 88 90 50 58 � �f _T � 1/2 NPT P K H NPT BOTH ENDS L A W N Mountable in any position. F v 322 8210 NCR1 Features • Fligh jnta-grity hot forged brass body • ISO 6211 actuator rnainUncl pgrj • Blr-Av-out proof stern • PTFE seats, 0-ring bacKed low opetatirg torqLlg • AdjustaNe PTFE packinci, with stem O-ring • 100% gated • Ls�ver operator s U Temp' —er u Curves M MMMMM MMMLIN — M 1�i Torque in-lbs (N-�) Flow Coeff id ent, Cv (Kv) "I'l" MMW 5:3 (6) Sikfe Entry 3181 0410 �°3 (6) 3.5 r)) fre* , L-(.'4.i 5 53 (6) 4.2 (2,6) 314' =Kim= 5s (6) 7.0 (C,.0)_ 1', IDN25 151 (1 7) 12.8 11.1 1-114", =11MUM MMUMM 18,7 (16,1) .1611 - DAO 151 r17) 20.8 (26,7) 27 ON [ 274 i31) 43- 8(37,7) L3 3T-3300RTTS Series Multi Port Valve 3L-3400RTTS Series Multi Port Valve Valve S¢e Inches: .;..Nps Torque in-lbs (N-�) Flow Coeff id ent, Cv (Kv) "I'l" all$ 5:3 (6) Sikfe Entry 3181 0410 �°3 (6) 3.5 r)) fre* , L-(.'4.i 5 53 (6) 4.2 (2,6) 314' CO20 5s (6) 7.0 (C,.0)_ 1', IDN25 151 (1 7) 12.8 11.1 1-114", DtW 15107) 18,7 (16,1) .1611 - DAO 151 r17) 20.8 (26,7) 27 ON [ 274 i31) 43- 8(37,7) 3T-3300RTTS Series Multi Port Valve 3L-3400RTTS Series Multi Port Valve LINI EN 12166 CWIE171,1 (58Cu-4QZji-1Pb) ;equvadrtii,) Hot Foining Ora>s UN C377W UNI EN 12164 CIN4310.1 (58Ctj-39Zr)•3Ft�) bal UNI G3&&)0 (�•7Cu•40Zn-3Pt.) Product Scope Size Range 14 - 2'. Reduced Port, FNPT Ends Port Type L-Port or T-Fort Port 06eil.aticii Sikfe Entry Pressure Rating 400 psi VV1DG (,:,VVP) (27,5 bar) Terrip?rature RiQ.�e ) VVSR -4'F INU 344 °F 1100 psi Steam -200C lhrL1 1731C 17 bar Steam Eddy P-j'ass, Hot Forged, Ni Riled Ball & Stern E rass, Ctwome Rated pall 'Seats PTFE. Viton 0 -ring backed --Stefjj Packing stable PTFE �.tern GqalsteodySevls ViLon 0 -rings Operator I MounliiNj Pad Manual Lever, Desi2n Standards Trwe. ad Design_ ANSI Testing Standards R,essure Testing 100,),,*, 9 80 r-,,si in opfn 8: I oosition LINI EN 12166 CWIE171,1 (58Cu-4QZji-1Pb) ;equvadrtii,) Hot Foining Ora>s UN C377W UNI EN 12164 CIN4310.1 (58Ctj-39Zr)•3Ft�) bal UNI G3&&)0 (�•7Cu•40Zn-3Pt.) Part Material Specification POdV 'Eras CLj7n40Pb2 End Car) 0,311 •eats PTFE Thrust Washer Fearing, Stem "C" Fan 9. Stem %litort' R no, Seat SC. pw plat•kj Steel Eushinc 'Pri3s (;U7n�-9PW IL 'dasher Nvion Handle Rated SLr-,el LINI EN 12166 CWIE171,1 (58Cu-4QZji-1Pb) ;equvadrtii,) Hot Foining Ora>s UN C377W UNI EN 12164 CIN4310.1 (58Ctj-39Zr)•3Ft�) bal UNI G3&&)0 (�•7Cu•40Zn-3Pt.) Position Flow Pattern A B C T3 Jr T.4 1 1F1! 900 T8 §00 IL T9 • 9.1 Ile 90, 4f L3 L OA ric ror! ART0792 (3) QK Holes on OJ Bolt Cirrle F ::,QR. 4144a Body Port j 3 BaM&Sle. PWDeslgn Stem Packing Valve End Connec9ons Size F Reduced Port -cti T T F '3,3 = ','<00 Of.) = Gia�s R = Coed dkv--ed T = FTFE T FTFE Size 01;�i• -- = OfT L Inches OA B 0 D F OH ISO 0i OK L M Weight, -210 2763— Weight, 52111 521, 075 lbs 114" 0.:39- o.4,5 2L4 -LA ONO 0.77 0.77 -I..;Ic .11 :1 >50 1) - I ?, 4 F(I'' F 0 -S 1.112 1.1-2 d 1) �!4 C1. ",'I 72 4�i2— 2. .114 1,0 1.0 11 1:143 I 47 0, 5 0.77 0.9 67,1 2. S l'o 19,• — 19.(-' -4� �--. 1 P)2 I 1.142 U,-'4 .4.7 21 .:1 - 4-1 1-2 1-20 12 ( '7"; 2 19 Cirl2s 0 ,1.37 1.25 0 35I) 1 511 F- C42 1, 4 L� C1,24 4. 7 21 170 j.'! —LL D132 1 24.9 '112 1.0 17, Q .27 6,0 0 DN40 1 ��72- j) 12-1 3 Fo", ",:)7 10. 71 9 F05 --60,0 6r), 0 7 4 i7) 2. 34 0410 2' .R F C, 1.97 T tTT7 F7-6 3 ('Ir5 7 C) C, 7, 53 3. ?8 rrU7 I 7F I :1, 1 :6), 4 '17.1 4144a Body Port 'Ball Port 3 BaM&Sle. PWDeslgn Stem Packing Vatve 'size End Connec9ons Size F Reduced Port -cti T T F '3,3 = ','<00 Of.) = Gia�s R = Coed dkv--ed T = FTFE T FTFE S (RIPT) 01;�i• -- = OfT L 0 NPS OA B C D I F 0H ISO I ej 0K I L I I M -210 2763— Weight, 521, 075 kg s ONO 9 I 07,1 1 34,0 F0 3g.o 1 1 125 62 0, 5 C41 1,-, 0.9 67,1 2. S l'o 19,• — 19.(-' -4� �--. 1 J 0.L; —2.0 14,0 '3 C" R.2--L—�� el. 1 L— 1-20 12 -2 L--- L- C,4:' O.E• 0,:3 Cirl2s 21J _ 911,f) 25.4 -11,4 10,9 —1t,. 4�?,O F 1) .6 170 76 —LL D132 1 24.9 '112 1.0 17, 6 1.9 Fl15 DN40 1 ��72- j) 12-1 3 46,6 59,4, 10. 71 9 F05 --60,0 6r), 0 7 j;q 1 1.43 47 6 F1.17 C) W3 7, 53 4144a Body Port 'Ball Port Wes BaM&Sle. PWDeslgn Stem Packing Seat End Connec9ons Size F -cti T T F '3,3 = ','<00 Of.) = Gia�s R = Coed dkv--ed T = FTFE T FTFE S (RIPT) 01;�i• -- = OfT L 0 1 TiCj 10— 0SI., -210 2763— 075 200 oral -nng Schematic nPqu1fo0•3p"io1-mf1oNn1ng of top pad, Marwin Valve A Division of Richards Industries, 3170 Wasson Road, Cincinnati, 01-1 45209 toll free. 800.543331111, local- 513.533.5600, fax. 513.871,0105 www. marwinvalve. con'i Ir VEEDER -ROOT ITEM #50 14, July -2003 MSR XX -03 -A Position Sensitive Pan /Sump Sensor 1.0 Purpose This Marketing Sales Release (MSR) announces the release of the Position Sensitive Pan /Sump Sensor 2.0 Product Description and Overview Correct positioning of Pan /Sump sensors is critical to ensure accurate detection of liquids in the sump and /or dispenser pan. Many local regulatory agencies, especially in Southern California, have enacted legislation and regulations that make it not only punishable with fines but also a criminal act to knowingly alter a sump sensor's position. To ensure the placement of the sensor remains at the bottom of the Pan /Sump, V -R has developed a way for the sensor to alarm if it is no longer in contact with the bottom of the Pan /Sump. If the sensor is raised off the bottom of the pan /sump, a "Sensor Out" condition /alarm is created at the console. By utilizing the Position Sensitive Pan /Sump sensor from Veeder -Root, the customer can be assured that they are in compliance with local regulations and that their sensor is properly positioned. 3.0 Launch Schedule As of the date of this MSR, the Position Sensitive Pan /Sump Sensor will be available for immediate shipment. A core credit of $30.00 will be issued for each Piping Sump Sensor returned (P /N 794380 -208 & 794380 -209) when purchasing the same quantity of the Position Sensitive Sensors. To receive the credit you must request an RGA from Customer Service referencing your original Purchase Order on which the Position Sensitive Pan /Sump Sensors were ordered. Contact customer service for more details. 4.0 Product Nomenclature Part Description Item /Capacity Part Number List Price Position Sensitive Pan/Sump Sensor 1 Pan /Sum 794380 -323 $235.00 20' Replacement Cable 1 Cable 0331102 -001 $80.00 2 Wire Sensors with Connector must order when replacing 794380 -209 5.0 Application Assistance For further information, or for application assistance, contact: Veeder -Root Company Customer Service ITEM #50 PO Box 1673 6th Ave, at Burns Crossing Altoona, PA 16603 Tel: 1- 800 - 873 -3313 Fax: 1- 800 - 234 -5350 Other Contact Information: Veeder -Root Company, Simsbury, CT. U.S.A. Veeder -Root Company, EMEA (Corp. Office /England) Veeder -Root Company, France Veeder -Root Company GMBH Veeder -Root Europe, Middle East and Africa 1- 860 - 651 -2700 44 -20- 8392 -1355 33- 148 - 795 -5599 49- 716- 390 -9400 44- 185- 841 -0310 Veeder -Root Australia and New Zealand 61 -3- 59776534 Veeder -Root Singapore r, 65- 6745 -9265 Veeder -Root (Beijing) China 1 010- 651 -28081 Veeder -Root Brasil 38- 796600 For International Customers To reach Altoona, Pa. U.S.A. Customer Service Tel: ++ 1- 814 - 695 -4476 Fax: + +1- 814 - 695 -7605 1v1agnULo for Alter . .... ... . . ..... 0 Certified performance for inventory control and in -tank leak detection in fuel blends up to 100% alcohol Veeder -Root offers two types of Magnetostrictive Probes for Alternative Fluids to provide highly accurate, trouble - free in -tank leak detection and inventory control in fluids of up to 100% alcohol. The Magnetostrictive Probe for Alternative Fluids with water detection is ideal for fuel blends with less than 20% alcohol. The Magnetostrictive Probe for Alternative Fluids without water detection has been developed for fluids up to 100% alcohol. Series 8463 0.1 GPH Mag Probe for Alternative Fluids The 0.1 GPH Mag Probe for Alternative Fluids has been third -party tested and certified to perform far better than the U.S. E.PA. standards for both 0.1 GPH volu- metric tank tightness testing and 0.2 GPH automatic tank gauging. (See the summary of leak test performance on back or call us for a copy of the complete test results.) 0.1 GPH Mag Probe and CSLD — Leak detection without shutting down your tanksl CSLD, Continuous Statistical Leak Detection, is an advanced tank testing tech- nology that makes full use of the TLS -300 and TLS- 350(R)'s in -tank monitoring capa- bilities. CSLD eliminates the need for tank shutdown to perform a leak test — no lost business, no lost operating time! ail vl:i: ER Roar The TLS -300 and TLS- 350(R) equipped with CSLD use the 0.1 GPH Mag Probe to continuously monitor fuel height and tem- perature information to detect idle times in the tank. During each idle time, data collected forms a highly accurate leak detection database. Sophisticated statistical analysis techniques in CSLD constantly evaluate the database to discard invalid data and perform leak tests based on only high - quality information in the current database. In fact, a new leak test is performed every time new data from an idle period is added. Series 8463 0.2 GPH Mag Probe for Alternative Fluids The 0.2 GPH Mag Probe for Alternative Fluids provides the same reliable inventory control features and fluid compatibility as the 0.1 GPH Mag Probe for Alternative Fluids, but offers 0.2 GPH leak detection at a lower cost. Features & Benefits • Non - corrosive, stainless steel tubing for long -life monitoring in fuels up to 100% alcohol • Highly accurate Magnetostrictive measurement technology i • Fast accurate leak tests • 0.1 GPH Mag Probe for Alternative Fluids is third -party certified to exceed U.S. E.P.A. performance standards for 0.1 GPH Volumetric Tank Tightness Testing 0 The 0.2 GPH Mag Probe for Alternative Fluids has also been third -parry tested and certified to exceed U.S. E.P.A. standards for 0.2 GPH automatic tank gauging. (See the summary of leak test performance on back or call us for a copy of the complete test results.) Approved for Aboveground Tank Applications Veeder -Root Magnetostrictive Probes are approved for use in aboveground storage tanks to monitor fuel inventory. An AST installation Kit (Form Number 312020- 984) is required for these applications and is available from Veeder -Root, Customer Service 800 - 873 -3313 or your authorized Veeder -Root distributor. • 0.1 GPH Mag Probe for Alternative Fluids is compatible with TLS -300 and TLS -350R with CSLD for continuous statistical leak detection • 0.2 GPH Mag Probe for Alternative Fluids is third -party certified to exceed U.S. E.P.A. performance standards for 0.2 GPH Automatic Tank Gauging • 2 ", 3" and 4" Float Kits available Magnetosocwe Probes torah n thvFluas are emdable 17 0.1 GPH and 0.2 GPH Versbns ITEM #51, #52 Probe Models TEST TYPE Inventory: Yes Meg Plus Probes for Alternative Fluids with Water Detection Part No' Mag Plus Probes for Alternative Fluids without Water Detection Part No' Mag Plus Probe for Alternative Fluids with Water Detection Tank I.D. 0.1 GPH Leak Detection 0.2 GPH Leak Detection Inventory Only 0.1 GPH Leak Detection 0.2 GPH Leak Detection Inventory 4' 846391 -101 846391 -201 846391 -301 846391 -401 846391 -501 846391-601 0.2 GPH Mag 2 5' 846391 -102 846391- 202 846391 -302 846391 - 402 846391 -502 Alcohol / Ethanol (< =100% 5'4" 846391 -103 846391 - 203 846391 -303 846391 - 403 846391- 503 846391 -603 6' 846391 -104 846391- 204 846391 -304 846391 - 404 846391- 504 846391 -604 7' 846391 -105 846391 -205 846391 -305 846391 - 405 846391- 505 846391 -605 7'6" 846391- 106 846391 -206 846391- 306 646391- 406 846391 -506 846391 -606 8' 846391- 107 846391 -207 846391 - 307 846391 -407 846391 -507 846391 -607 9' 846391- 108 846391 -208 846391 - 308 846391 -408 846391 -508 846391 -608 916" 846391- 117 846391 -217 846391 - 317 846391 -417 846391 -517 846391 -617 10' 846391 -109 846391 -209 846391 - 309 846391 -409 846391 -509 846391 -609 10'6" 846391 -110 846391- 210 846391 -310 846391- 410 846391- 510 846391 -610 11' 846391 -111 846391 - 211 846391 -311 846391 - 411 846391 -511 846391 -611 12' 846391 -112 846391 - 212 846391 -312 846391- 412 846391 -512 846391 -612 2.OM 846391 -113 846391 -213 846391 -313 846391- 413 846391- 513 846391 -613 2.5M 846391 -114 846391 -214 846391 - 314 846391 -414 846391 -514 846391 -614 2.67M 846391 -116 846391 -216 846391 - 316 846391 -416 846391 -516 846391 -616 3.OM 846391 -115 846391 -215 846391 - 315 846391 -415 846391 -515 846391 -615 Custom Length 846391 -199 846391 -299 846391 - 399 846391 -499 846391 -599 846391 -699 Tbat (tits must be ordered sepsratay from Probes, water /bats not raco,n —ded for fuel blends with >20% abahol Floats Match Table Product Probe Functions Float Kit Leak Test Performance (Third Party Certified for all TLS -3xx Consolesl IPROBE - TEST TYPE Inventory: Yes P(FA) TEST TIME Mag Plus Probe for Alternative Fluids with Water Detection Leak Detection: Yes Gasoline Float Kit 1% P/N 846391 -1xx or -2xx Water detection: Yes P/N 846400 -xyO- Gasoline ( < =20% Alcohol) ('see note for Inventory Only Mag Plus Probe for Alternative Fluids with Inventory: Yes 0.2 GPH 99% <.1 % definition of xy 0.2 GPH Mag 2 Water Detection Leak Detection: No below) 2 Hours P/N 846391 -3xx Water detection: Yes Alcohol / Ethanol (< =100% Mag Plus Probe for Alternative Fluids without Water Inventory: Yes Alternative Fluids Alcohol, including E85) Detection Leak Detection:Yes Float Kit Methanol (< =100% Alcohol) P/N 846391 -4xx or -5xx Water Detection: No P/N 846400 -xy4' Mag Plus Probe for Alternative Fluids without Water EfBE (< =100% Ether) MTBE (< =100% Ether) Detection Notes: Used Oil PIN 846391 -6xx -> x =0 4' floats Inventory: Yes Leak Detection:No x =1 -> 2" floats x =3 -> 3" floats Fuel Oil #4 8 #6 Fuel Oil #4 8 #6 Mag Plus Probe for Alternative Fluids without Water Detection: No Ethylene Glycol Water Detection y=0 -> 5' cable Propylene Glycol P/N 846391 -6xx y =1 ->10' cable Windshield Washer Fluid y =2 -> 20' cable Leak Test Performance (Third Party Certified for all TLS -3xx Consolesl IPROBE - TEST TYPE P(D) P(FA) TEST TIME 0.1 GPH Mag Probe 0.1 GPH 99% 1% 3 Hours 0.1 GPH Mag Probe 0.2 GPH 99% <.l% 2 Hours 0.1 GPH Mag Probe w /CSLD 0.2 GPH 99% <.1 % Continuous 0.2 GPH Mag 2 0.2 GPH 99% <.l% 2 Hours feeder- -Root reserves the right to change product spWcatons without advance notice. Hose ensure that )vu are usog the latest vosion of product b4eretwe. r- -1 VEEDER-ROOT O 2007 Veeder -Root Company - 125 Powder Forest Drive - Simsbury, CT 06070 Telephone: 860 - 651 -2700 - Fax: 860 - 651 -2719 - www.veeder.com USA VR 12960 P/N 577013 -054 Rev.0 VR 6/07 interstltlal sensor for steel lanxs ir-I MEWR r I rage 1 01 Z ITEM #54 Contact Us I Site Map I I SEARCH ► Home Extranet Products Locate Distributor Locate Service FMSOnline Support Worldwide Company News & Events ATGITLS Monitoring Products Request ATGITLS Information ATG(TLS Monitoring Consoles & Accessories Direct AccessT Software Secondary Containment Vacuum Sensing System Wireless Tank Gauging Tank Measurement Sump Monitoring Dispenser Pan Monitoring Double Wall Tank Monitoring Interstitial Sensor for Steel Tanks Interstitial Sensor for Fiberglass Tanks Solid State Discriminating Interstitial Sensor Hydrostatic Sensor Micro Sensor Monitoring Wells Monitoring & Installation Accessories Product Line Monitoring Enhanced Vapor Recovery Solutions Red Jacket Products Fuel Management Services VRM Registration Products Product Brochures Interstitial Sensor for Steel Tanks Our products offer the following features and benefits: The Veeder -Root Interstitial Sensor for use in Steel Tanks detects the presence of liquid in the interstitial space of a double -wall steel tank. Liquid in the annulus could mean a dangerous leak. When liquid is detected, the sensor sends an alarm signal to a TLS -350R, TLS -350, TLS -3501, ILS -350, TLS -3001, or TLS -300C monitor. The monitor's visual and audible built -in alarm indicators immediately tell you where the problem is, so you can quickly take action to help prevent serious safety and environmental problems. The TLS -350R, TLS -350, TLS -3501, ILS -350, TLS -3001, TLS -300C, TLS -2501, and ILS -250 systems feature internal alarm relays that can also trigger on -site alarms for even greater warning capability. The TLS -350R, TLS -350, TLS -300i, and TLS -300C alarm signals from the sensor triggers a report showing the time and the location of the alarm condition. This information is stored in the system's alarm history and can be retrieved through the monitor's integral printer or remotely through its data communications interface. The Veeder -Root Interstitial Sensor for Steel Tanks can used in the annulus of steel tanks with a sensor riser pipe 1.5" I.D. or greater. Only two wires are required to connect the sensor to a TLS or ILS system. Features The presence of any liquid in the tank's interstitial space triggers a Fuel Alarm Temperature Rating Storage: -40 degrees C to + 75 degrees C Operating: -20 degrees C to +70 degrees C (hydrocarbons); 0 degrees C to +70 degrees C (non- freezing water); Cable length: 16 or 30 feet Dimensions: 2.5" high, 1.50" diameter Standard Components Quantity Description 1 Interstitial Steel Tank Sensor 2 Watertight Cord Grips Standard Models Form No. Description 794390 -420 Interstitial Steel Tank Sensor with 16" cable 794390 -460 Interstitial Steel Tank Sensor with 30" cable Interstitial Steel Tank Sensor Console Capability The Series 7943 interstitial Stpel Tank Sensnr is romnatihlp with the fnllnwinn rnnsnles- Console Series LS -350R* 8482 LS -350* 8470 11i+Y�•�� \S 1)S 1)1) ­.A ,4Ar Qii 1) /1)1)1 n lnierstlllal censor for steel i arms ITEM #54 rage Z 01 LS -3503 8470 ILS -350 ** 8450 LS -300i 8485 LS -300C 8485 *Note: An Interstitial Sensor Interface Module is required for the use of the Interstitial Fiberglass Tank Sensor with the TLS -350 Console. * *Note: A Two -Wire Module is required for use of the Interstitial Fiberglass Tank Sensor with the ILS - 350 Console. - Related Links and Documents » Interstitial Liquid Sensor - Fiberglass Tanks - Installation Guide (576013 -617 Rev E) (PDF) Point Sensor - Liquid Contact Product Detectors - Certification Reports - Results of U.S. E.P.A. Standard Evaluations (576013 -864 Rev G) (PDF) Products: TLS -350, TLS -300, TLS -300i, ILS -350, EMC, EMC BASIC, ProMax, ProPlus, Simplicity » Liquid -Phase Product Detectors - Results of U.S. E.P.A. Standard Evaluations (576013 -917 Rev. B) (PDF) Products: 847990- 001,847990 -002 Sensor Products - Application Guide (577013 -750 Rev M) (PDF) Solid -State Interstitial Liquid Sensor for Fiberglass Tanks - Installation Guide (576013 -826 Rev G) (PDF) w Interstitial Liquid Sensor - Steel Tanks Installation Guide (576013 -616 Rev E) (PDF) w Fiberglass Interstitial Sensor Installation Kit - User's Guide 577013 -802 Rev B) (PDF) Contact Us I Danaher Corp I Gilbarco I Gasboy I Privacy I Legal I Site Map Copyright © 2009 The Veeder -Root Company All rights reserved. Unauthorized duplication prohibited. 1,+y„ • I ��. n1 n: � � �aa.7 ar nnm I�, n na !Tn tFarc� +� ii n � C an n nrC +cal Q i � � i� n I n I!B BRAVO SYSTEMS ITEM #60 - Conduit Series Pass - through Fitting Size over Size Termination Fitting PRODUCT SPECS: Material .... UL Fiberglass PART # PART # O.D. Length Weight Engineered for F- 17 -SS: 5" 5.25" 3 Ibs 3/4" Hot -dip Galvanized Conduit F- 10 -SS: 5" 5.25" 3 Ibs 1" Hot -dip Galvanized Conduit F- 17 -RR: 5" 5.25" 3 Ibs 3/4" RobRoy PVC - Coated Conduit F- 10 -RR: 5' 5.25" 3 Ibs 1" RobRoy PVC - Coated Conduit Size over Size Termination Fitting Ameron LCX Termination Fitting PRODUCT SPECS: Material .... UL Fiberglass PART# O.D Length Weight Englneered For. F- 22 -LS: 7" 5.25" 5 Ibs 2" Ameron LCX Fiberglass Pipe F- 33 -LS: 7.5" 5.25" 6 Ibs 3" Ameron LCX Fiberglass Pipe Reduce Labor & Material Minimize Installation Errors All "FRP" Construction 3rd Party Approved C @ US LISTED Stock ONE fitting for both SMITH / AMERON * THIRD PARTY APPROVED ONLY F -32 -TS -ADJ Angle- Adjustable 0° -5° - Plastic - Rubber - Clamps - Sealant N 0 -Nuts -Bolts S. Bravo Systems. Inc. - The Leader in Secondary Containment 2929 Vail Ave. Commerce, CAI 323 - 888 -4133 FAX: 323 - 888 -4123 www.sbravo.com lc-" R I I PRODUCT SPECS: Material .... UL Fiberglass PART # 0.13 Length Weight Engineered For F- 32 -TS: 7" 5.25" 5 Ibs 3" over 2" Fiberglass Pipe F -32 -TS -ADJ: 7" 5.25' 5 Ibs 3" over 2" Fiberglass Pipe F- 43 -TS: 7.5" 5.25' 6 Ibs 4" over 3" Fiberglass Pipe F -43 -TS -ADJ: 7.5" 5.25' 6 Ibs 4" over 3" Fiberglass Pipe F- 64 -TS': 11" 5.25" 11 Ibs 6" over 4" Fiberglass Pipe Ameron LCX Termination Fitting PRODUCT SPECS: Material .... UL Fiberglass PART# O.D Length Weight Englneered For. F- 22 -LS: 7" 5.25" 5 Ibs 2" Ameron LCX Fiberglass Pipe F- 33 -LS: 7.5" 5.25" 6 Ibs 3" Ameron LCX Fiberglass Pipe Reduce Labor & Material Minimize Installation Errors All "FRP" Construction 3rd Party Approved C @ US LISTED Stock ONE fitting for both SMITH / AMERON * THIRD PARTY APPROVED ONLY F -32 -TS -ADJ Angle- Adjustable 0° -5° - Plastic - Rubber - Clamps - Sealant N 0 -Nuts -Bolts S. Bravo Systems. Inc. - The Leader in Secondary Containment 2929 Vail Ave. Commerce, CAI 323 - 888 -4133 FAX: 323 - 888 -4123 www.sbravo.com lc-" R I I ITEM #60 - #63 F=SERIES PASS - THROUGH PIPING The F- Series penetration fittings allow the primary pipe to pass through. The secondary pipe terminates within the fitting, eliminating the need for clamshells or reducers at the fitting face. * ALL SMITH FIBERCASTTM PIPE, BRAVO 9000 -B SUMPS, FLEX CONNECTORS AND SHEAR VALVES ARE FOR ILLUSTRATION PURPOSES ONLY. A Optional: -SS Test Port to test / monitor Secondary Pipe AM EL Primary passes through EL fitting for testing, while not permanently installed yet. I r— I After primary passes testing, the primary is then sealed to the fitting by adhesive injection The secondary is then sealed and tested. The Adjustable Variant of the F- Series Fitting utilizes an additional loose flange machined with a 2.5° angle to match a 2.50 angle on the integrated flange of the body. Rotating these together allows a 00 - 50 angle adjustment. S. Bravo Systems. Inc. - The leader in Secondary Containment 2929 Vail Ave. I Commerce, CA 1 323 - 888 -4133 1 FAX: 323 - 888 -4123 1 www.sbravo.com ���E^ A FIBERGLASS - COMPOSITE PIPE GROUP ITEM #70 - #80 Dualoy 3000/L Secondary Containment Pipe and Fittings UL- Listed nonmetallic underground containment piping for petroleum products, alcohols and alcohol - gasoline mixtures Uses and applications Service station product, vent and vapor recovery piping Bulk plant terminals and fueling terminals Central fuel oil systems Marinas and marine terminals All piping systems requiring UL or ULC listing for petroleum products, alcohols, and alcohol - gasoline mixtures Containment piping for all of the above Description Dualoy 3000/1- secondary containment systems employ pipe one size larger than the primary and specially designed fittings. The system provides complete enclosure of UL- and ULC- listed Ameron primary piping used in product lines and vapor recovery lines from the sump at the product storage tank to the shear valve at the dispenser, and vent lines from the tank. Dualoy containment systems have been sized for close make -up and ease of installation. Features of Ameron Dualoy 3000 /L containment systems include: • Filament - wound, fiberglass - reinforced pipe with integral liner; • Compact fittings dimensions to minimize trench excavation; • Smooth exterior pipe surface that eliminates the need for special end preparation tools; • Ready accessibility to and complete inspectability of primary fittings prior to closure of the containment; • Complete testability during installation and at any time thereafter; • Rapid joint makeup with pop -rivet closure and ambient cure adhesive. Listings Dualoy 3000 /1- is listed in the United States with Underwriters Laboratories for nonmetallic underground piping for petroleum products, gasoline - alcohol blends and V Underwriters alcohols for both primary (File MH9162) and containment (File MH15596) piping systems. Dualoy 3000 /L pipe and fittings are also listed with Underwriters' Laboratories ®L Laboratories IOC ® of Canada for petroleum products and oxygenated fuels (File CMH 715) and with the French Ministry of the Environment (Arret6 261 bis). In Great Britain the Dualoy 3000/L system has been tested and accepted by the London Fire and Civil Defence Authority and has been issued a Certificate of Compliance to the Institute of Petroleum (IP) Specification by ERA Technology, Ltd. Performance Operating pressures to 100 psig Ccinlhwous'upwaMig teinl)eralure s to 1507 (66 "C) ISO -9001 Individual system components may not have the same ratings as the pipe. Refer to the detailed product information for the specific components to determine the e pressure rating for the system as a whole. FP400C (7/00) aM Piping system characteristics Only end prep required :7 Is the removal by light sanding ofsurface gloss. The end section of a run of containment pipe is placed inside the center section, providing. easy access to the primary joint at one end of the run. Two -inch primary pipe contained within 3 -inch or3112-inch containment pipe can be repaired with a UL- listed 2 -inch repair coupling. The containment is restored by replacement of a section of the existing containment pipe with a 4 -inch con talnm4i f nipple. The 4-Inch replacement nipple is then joined to the existing containment pipe with Dualoy reducing couplings. ITEM #70 - #80 Secondary employs full - performance pipe — Many contained fuel handling systems employ materials in the secondary that fall far short of the primary piping in regards to chemical resistance and mechanical. strength. By contrast, Dualoy 3000 /L systems employ the same type of high - performance fiberglass- reinforced pipe in the secondary as. in the primary. Thus, Dualoy 3000 /1- containment systems easily withstand both high external loads from backfill and traffic as well as internal pressures as high as 100 psig. Compact containment fittings — Dualoy 3000/1- containment fittings are more compact than competitive clam -shell type closure pieces. As a result, crossovers in a Dualoy 3000 /1- system occupy less space, so less excavation is required than with competing rigid -wall containment systems. Precision pipe exterior eliminates scarfing — Dualoy pipe is manufactured in a proprietary continuous winding process that provides an extremely precise, consistent outside diameter. No scarfing of the pipe end is required to achieve a proper fit of the secondary pipe inside closure pieces. Light sanding of the pipe end to remove the surface gloss and obtain a suitable bonding surface is the only end prep required. Easy accessibility to primary fittings — Dualoy systems provide convenient access to primary fittings during bonding, testing and inspection by using lengths of containment pipe of different diameters and appropriate reducing couplings. in most layouts the Nilii�� ERIE 9! primary can be contained by three pieces of secondary pipe as shown above. The 3 -inch lengths at the ends of the run are one size larger than the primary line; the middle piece is 31h -inch containment pipe. The 3 -inch containment sections slip readily inside the 31h -inch section. By manipulating the sections, ready access to the primary fittings can be achieved during installation and testing. Complete retestabllity— Dualoy 3000 /1- containment employs rigid -wall pipe and fittings that maintain their shape during the entire service life of the station. When installed with isolating penetration fittings (see page 4), Dualoy 3000 /1- containment piping can be repeatedly retested whenever desired. Rapid containment fitting assembly with the Ameron Rivetool — Owing to the extremely precise outside diameter control of Dualoy 3000 /1- containment pipe and the ample thickness of Ameron containment fittings, Dualoy 3000 /L containment systems can be assembled with rivets rather than cumbersome wing -nuts or conventional bolts. The easy -to -use pneumatic Ameron Rivetool provides identical tension on every rivet. Riveted closure is four to five times faster than closure with bolts. Convenient repair capability— Contained piping systems are occasionally damaged after installation. Damage is generally caused by paving or excavation operations. Dualoy 3000 /1- contained piping systems are designed so that only the damaged stretch need be replaced instead of the entire line. The 2 -inch Dualoy repair coupling is sized so that it can be contained within 4 -inch Dualoy 3000 /1- containment pipe. 4 x 3 Inch reducing couplings 2 -Inch repair coupling 0 0 0 0 0 0 0 0 Align wing -nuts parallel to pipe to permit 4- inchplpe 4- hich pipe to slip over repair coupling 0 0 0 0 0 0 0 0 90° elbows 3 80 4.28 7.28 - 1.50 5 1.1 4 100 4.77 8.25 - 1.50 5 1.3 ar-I 6 150 5.62 10.53 - 2.00 8 1.5 Xz B ;� � 450 elbows 3 80 3.50 6.00 - 4 100 ITEM #70 - #80 7.00 - 6 150 6.32 9.75 - o Containment pipe and Nominal 100 4.78 No. of fittings dimensions Pipe Size A B c X2 Bolt Holes Wt. (in) (mm) (in) (in) (in) (in) (Ib) Pipe 3 80 3.50 3.32 - - - 0.72 3' /2 90 3.88 3.70 - - - 0.85 4 100 4.50 4.33 - - - 1.00 -- B 6 150 6.63 6.39 - - - 2.10 90° elbows 3 80 4.28 7.28 - 1.50 5 1.1 4 100 4.77 8.25 - 1.50 5 1.3 ar-I 6 150 5.62 10.53 - 2.00 8 1.5 Xz B ;� � 450 elbows 3 80 3.50 6.00 - 4 100 3.75 7.00 - 6 150 6.32 9.75 - 1.50 5 0.8 1.50 5 1.2 2.00 8 1.5 Tees 3 80 4.28 7.24 8.56 1.50 5 1.2 o 4 100 4.78 8.25 9.58 1.50 5 1.6 6 150 5.72 10.67 11.65 2.00 6 1.7 0 0 01 -- B -- A o o Xz Couplings 2 50 14.00 4.00 - 1.50 8 1.3 0 3 80 14.00 6.00 - 1.50 8 1.7 4 100 14.00 7.00 1.50 8 2.0 ao B 6 150 14.19 9.75 - 4.00 10 2.0 0 0 0 A �- Saddles 3 x 2 80 x 50 4.00 6.00 - 2.15 - 1.3 �- B 4 x 2 100 x 50 4.50 6.00 2.15 - 1.7 6 x 2 150 x 50 5.56 7.75 2.15 2.1 X.1 3 ITEM #70 - #80 Reducers, plain andwith 301/2 11/2 80 x.40 6.25 4.48 6.10 1.50 4 0.6 3/4 -inch NPT outlet 301/2 11/2 80 x 40 6.25 4.47 6.10 1.50 4 1.11 INTERNATIONAL 3 x 2 80 x 50 6.25 4.90 6.10 1.00 4 0.7 F ° ° 7 4191 MZ Geldermalsen Tel: (940) 569 -1471 Newnan, Georgia 30263 Mineral Wells, Texas 76068 Tel: 65 8616118 71he Netherlands Fax: (940) 569 -2764 Tel: (770) 253 -2000 Tel: (940) 325 -1341 Fax: 65 862 1302/8617834 Tel: +31345 567 587 Fax: (770) 253 -9234 Fax: (940) 325 -9681 Fax: +31345 587 561 3 x 2 80x 50 6.25 4.90 6.10 1.00 4 1.11 C B 31/2 x 3 90 x 60 6.25 6.00 6.37 1.50 4 0.8 �- NA 4 x 3 100 x 80 7.00 6.00 7.00 1.50 4 0.9 X2 4 x 3 100 x 80 7.00 6.00 7.00 1.50 4 2.0' 1E, 4 x 3'/2100 x 90 6.25 6.36 6.98 1.50 4 1.0 6 x 4 1150000 100 7:17 7.62. 9.74 2.00 6 1.0 1) Ported reducer. ported reducer Sump penetration fittings Ameron sump penetrations are designed for use at turbine sumps and dispenser pans. Plain sump penetration fittings permit the annular space between the primary and secondary lines to communicate with the Interior of the sump or pan. Penetration fittings With factory- installed centralizers, sleeve couplings'and monitoring ports may be used to isolate the pipe annular space from the sump or pan. When the annular space is so isolated, the secondary containment line can be retested at any time and as often as desired. Crowned to fit 42 to 48 -inch risers 2 -Inch sleeve coupling; joins product (in side sums tom Centralizers (annular space open) 7igot x 11¢ or 2 NPT tamale; iris flax mrvv&nr it sids surrin Centralizers (annular space sealed) Important Notice This literature and the information and recommendations it contains are based on data reasonably believed to be reliable. However, such factors as variations in environment, application or installation, changes in operating procedures, or extrapolation of data may cause different results. Ameron makes no representation or warranty, express or implied, including warranties of merchantability or fitness for purpose, as to the accuracy, adequacy or completeness of the recommendations or information contained herein. Ameron assumes no liability whatsoever M% In connection with this literature or the Information or recommendations It contains. Product specifications are subject to change. A% AWRON FIBERGLASS - CoMrOSITH PIPE GROUP - HPnOQuARTERS INTERNATIONAL P.O. Box 801148 • Houston, TX 77280 -Tel: (713) 690 -7777 • Fax: (713) 690 -2842 • http: / /ivw%v.ameron.com Asia al Europe: Americas . _ Com Ites ._, Centron International Ameron (Pie) ltd. Ameron f3.V l?U:'8oz�98 Mr. oz 51370 I.0786x 490'" No. 7A, Tuas Avenue 3 l.F. Kennedylaan 7 Burkbumett, TX 76354 11 McBride Street 600 FM 1195 South Singapore 639407 4191 MZ Geldermalsen Tel: (940) 569 -1471 Newnan, Georgia 30263 Mineral Wells, Texas 76068 Tel: 65 8616118 71he Netherlands Fax: (940) 569 -2764 Tel: (770) 253 -2000 Tel: (940) 325 -1341 Fax: 65 862 1302/8617834 Tel: +31345 567 587 Fax: (770) 253 -9234 Fax: (940) 325 -9681 Fax: +31345 587 561 0 1889 Ameron • FP400C (7/00) supersedes FP4008 (6/95) • Printed in U.S.A. • 5M(3005C1 � F Gin SERUES o FGTTBMGS OUTLET BODIES GRSS GRSS /GRSSA Features Internal hubs • Blank cover included (Cat. No. GRRBC) • Compact design and multiple hub configurations • Furnished with internal ground screw • Cast -in brackets on cover for use with breaker -bar tools GRSS Type Furnished with seven internal hubs, two hubs are on the top and bottom, one each on the two sides and one hub in the back. Four close -up plugs supplied. Series GUM unions can be used. Furnished with 13 hubs, two on each side and five in back. Five close -up plugs are supplied. Material /Finish - Aluminum Body • Copper -free aluminum (less than 4/10 of 1 %) • Electrostatically applied powder coating Material /Finish - Duraloy Iron Body • Duraloy iron alloy • Tri -Coat finish of Electrozinc, Chromate Sealant and electrostatical - ly applied powder coating Material /Finish - GR Series Cover • Copper -free aluminum (less than 4/10 of 1 %) • Electrostatically applied powder coating GRSS Dimensions Items #85 ;r r Class I, Div. 1 & 2, Groups C,D Class II, Div. 1 & 2, Groups E,F,G Class III ® Listed - File E10514 $A• Certified - File LR11716 See files for details or call Killark. GRSS /GRSSA CATALOG NUMBER HUB SIZE NUMBER OF OPENINGS NUMBER OF CLOSE -UP PLUGS FURNISHED KILLARK ALUM. OURALOY IRON GRSS -1 GRSS -11M 1/2 7 4 GRSS -2 GRSS -21M 3/4 7 4 GRSS -3 — 1' 7 4 GRSSA -1 — 1/2 13 5 GRSSA -2 1 1 3/41 13 1 5 GASKET (RUBBER) EXTENSION' CATALOG NUMBER CATALOG NUMBER GEC -RG GRCEX -0 Adds 2 -7/8' to body depth. GRSSA Dimensions GRSS /GRSSA DIMENSIONS CATALOG NUMBER HUB SIZE NO. OF OPENINGS CLOSE -UP PLUGS FURNISHED DIMENSIONS IN INCHES COVER OPENINGS VOLUME CU. IN. A B C D E F G H GRSS -1 1/2' 7 4 3 -1/2' 3 -12' 2 -3/8' 2 -1/8' 1 -3/16' 4 -5/8' N/A 1 -1/4' 3-1/8' 29 GRSS -2 3/4' 7 4 3 -1/2' 3 -12' 2 -3/8' 2 -1/8' 1 -3/16' 4 -5/8' N/A 1 -1/4' 3 -1/8' 29 GRSS -3 1' 7 4 3 -12' 3 -1/2' 2 -3/8' 2 -1/8' 1 -3/16' 4 -5/8' N/A 1 -1/4' 3 -1/8' 29 GRSSA -1 1 1/2' 13 1 5 3 -12' 3 -1/2' 2 -3/8' 2 -1/8' 1 -3/16' 4 -5/8' 2 -178' 1-1/4' 3-1/8' 20 GRSSA -2 1 3/4' 13 1 5 3 -12' 3 -12' 1 2 -3/8' 1 2 -1/8' 1 1 -3/16' 1 4 -5/8' 2 -1/8' 1 1 -1/4' 1 3 -1/8' 20 ®• KILLARK' ITEM #87 Series 100 Rotary Hand Pump 100 Rotary Hand Pumo Shown FILL -01 M Description of Included Models Model Number Description Shipping Weight 110 Basic UL Listed pump with Vacuum Breaker 10 Ibs 4.5 kgs 112 Basic UL Listed pump with Vacuum Breaker, 8' Hose & Nozzle, 2" Bung 17 lbs 7.7 Adapter(1" inlet) and Telescoping suction tube kgs 113 Basic UL Listed pump Basic UL Listed pump with 2" Bung Adapter(1" inlet), 16 Ibs 7.3 Telescoping suction tube and Spout kgs 114 Basic UL Listed pump with 2" Bung Adapter(1" inlet), Telescoping suction 18 Ibs 8.2 tube, Spout and Drip Pan kgs Safety Listings Approval Mark Organization Description File Guide Number Number Underwriters Laboratories Inc., a nationally recognized independent organization for testing of products to ensure public safety. Recognized and accepted in USA,Canada and MH6988 EVRZ LITO other countries ITEM #87 Available Options Option Description Shipping Weight Shipping Weight 520OF1619 Discharge spout (lbs.) (kgs.) 113 Rotary pump equipped with Model 111 counter 11.0 4.54 40OF6634 kit. 100F1189 Telescoping steel suction pipe extends from 22" to 40" L Basic unit supplied with liter measure for - Suction tube lower section - 17" male end to 150 cut end VP62F9091 Series 100 7000KTF7183 Particulate filter kit -X001 Unit supplied less hose (3.0) (1.4) -X002 Unit supplied less telescoping suction tube (2.0) (0.9) -X003 Unit supplied less nozzle - - -X004 Unit supplied less spout (2.0) (0.9) -X005 Unit supplied less hose and nozzle (3.0) (1.4) Accessories Part Number Description 520OF1790 Hand pump Nozzle 520OF1619 Discharge spout 520OF1750 Hose - 5/8" X 8' with 3/4" ferrules 100ACC111 Counter kit 10OF0842 Barrel bung adapter 40OF6634 Wall mount bracket for this pump 100F1189 Telescoping steel suction pipe extends from 22" to 40" VP172F8617 Suction tube upper section - 17" female to female ends VP172F6834 Suction tube lower section - 17" male end to 150 cut end VP62F9091 Steel 1" X 8" nipple to attach suction tube sections to pump 7000KTF7183 Particulate filter kit 7000KTF7186 Hydrosorb filter kit ITEM #87 Performance Flow Capability Maximum Dry Vacuum Minimum Lift ** 10.3 Ounces (0.306 Liters) per Revolution. 6" of Mercury 8' of Diesel. For gasoline see below. Maximum Viscosity of fluid pumped SAE30 Motor Oil Maximum ambient operating temperature 150 OF (66 °C)* Minimum ambient operating temperature -15 OF ( -26 °C)* * Consult factory for extreme temperature applications outside this range. ** The lift in feet is equivalent to the vertical distance from the surface of the fluid in the tank to the inlet of the pump, PLUS the friction losses through the vertical and horizontal runs of pipe. All elbows and other fittings must be included in the calculation of friction loss. The system should be designed to require a minimum amount of suction lift. * ** Lift of gasoline dependent on Reid's vapor pressure of the gasoline and it's temperature. The lower the vapor pressure and temperature, the higher the possible lift. Refer to the attached Practical Gasoline Suction Lift Considerations to determine the gasoline lift you can expect. CAUTION: Only pump as clearly carrying the UL Listing Mark should be used with gasoline or any low flashpoint fluid. Look for the Mark. Fluid Compatibility The Series 100 Rotary Hand Pumps are designed for petro products of all types. If there is a question for a particular fluid, check the affects of that fluid on the following wetted materials. Cast Iron Steel Zinc Plated Steel Acetal Viton® Vellumold Also Nylon -110, 120, 112, and 122 Only Dimensions 1 1/2" Repair 1/2" 1 - -61/4" IN ITEM #87 The Series 100 rotary hand pumps is designed for long years of trouble free service. A number of the more common situations that have been noted are included in the frequently asked questions. If it becomes necessary to take your pump to a service center, always thoroughly flush with a compatible solvent, water for water based fluids and kerosene or diesel fuel for petro products, before packing. Refer to the Parts and Technical Service Guide packed with the new pump for additional service and repair ideas. A copy of the full guide is included under Reference Documents at the end of this page. Maintenance To keep the pump running at its best, periodically perform the following procedures: 1. Thoroughly flush using a compatible solvent, kerosene or diesel fuel, if the pump is to be stored unused for any period of time. 2. if leakage is noted around piston shaft, tighten packing nut in 1/4 turn increments until leakage stops. Over tightening will make pumping more difficult than is necessary. `m U CL r v m rn m C- COUPLER COUPLER X HOSE SHANK Made in the U.SA - gl PTlaae shanks are 9w must verSahle to atlad*v to lase. The spec* nw&tarb9d shank atm tar atladunent via argrral RaxirLok- centerparch damps (see pg 115 for mae demds), or by an inked PmGz D-C-50 temrle or sleeve (see pg. 515 -100 to move delarls. HBS cam amts are made of 300 sates Stainless Steel. HB can ams are made of Bratis Afl&w9ess Sfeer are 3 r6 and a/1 standard 000yovenly are 300 sffm Sf ALW Slod.. Please Cad to Special tie on coapAele can arm as wh* and components in 316 SOYzA ss Steel. 8, 10 and 12 axh wtplers are 4-an dessow Ofh the STA- LOK`posilrve bating feature. A#1- 12'to6 "Abnn wmo Hard Coal Mwik xncastings are avadade with Undersized shank To ooleradd the lefts 'US' after the adsbv _ ,_ _ Alwilnu_m /HBS _ Aluminum/MB _ _Brass /HB _ Brass /H_BS _ Size Part IIan # List Item # List Price Itern # List Price Item # List 314"x 1/2" Name 3/4' _ Price 27003_07_ $8.96 2770307 $10.87 2900307 Price 1/2 EOSC _ 1000301 #11.58_ -_ _ _1070301 _ #13.11_ 12003_01 #28.94 129x130.1 #27.26- l 3/4" x 1/2" 1-RC 1000305 � 1070305 S 1200305 _ $31.47 S _ ! 3/4' -- - ---- 07C -- 1000307 - -- $13.06 -__ -.. 1070307 -._. $ 14.55 _. 1200307 - $33.25 1290307 $31.58 1" 1 D 1000310 $13.49 1070310 .-'---- $15.61 1200310 -- --- - - $36.74 -- - - -- 1290310 -- -I $34.37 1 -1/4' 12C 1000312 $18.67 _ 1070312 _$20.78_ _1200312_ $47.63_ - 2400312_ $4516 11 1070315 1 -1/2' 15C 1000315 $17.76 $19.87 1200315 _ $53.76 _1290312 1290315 $51.40 Y _ 20C_ _ _ 1000320 _ $20_ .19_ _ _ _1070370_ - #71.31 - --$-22.-3-1- . 20 1200320_ $62.93 1290320 $60-57 2 -1/2" 25C 1000325 $31.13 1070325 _ $33.35 1200325 _ $82.45 1290325 $80.08 3 _ 30C 1000330 $31.62 1070330 _ $35.23- 12_00330_ $109.7_9 1290330 $105.75 4' 40C 1000340 $44.95 1070340 $48.56 1200340 $166.63 1290340 - $162.58 5' SOC 1000350 $78.09 1070350 $81.70 1200350 $269.19 12911350 $265.14 6' 60C 1000360 $114.24 1070360 $114.24 1200360 $480.08 'i3 'S - -_ - 8'- -- -80C 1000380 #449.96 1070380 $449.96 1200380 $769.96 . -'$ 10' 1000 1000390 $887.16 1070390 $887.16 1200390 $ a - it i u"- - - - -120C 1000392 #1,610.92 1070392 $1,610.92 - -� ---w .. Q I - ^ 116m MX&Ers listed above. Toll -Free: (800) 654-0320 • TO &Free Fax: (800) 828 -2649 • Nfo@ptcoupfing.oDm • www.ptcoupfiN.can ITEM #88 -- - Pat Stamm Shed_ ., Ductile Iron bard Coat Alum Carbon Steel Size Part Thee # List Item # _... List PAoe Item # list Price - _ 1ffin # List 314"x 1/2" Name 3/4' _ Price 27003_07_ $8.96 2770307 $10.87 2900307 Price 1/2" t3)SC' - 1400301 - -- _ $47.24 1800301 _- $16.65 _ 2000301 _ -___$17.47__ - $14.90 $ $ -- W­ 3/4'x 1/Y -_ -_ 1/2C '9 2 8 2000305 $17.47 2700315 $12.14 - 3/4' - 07C 1400307 $4714 _1800307 $16.65_ 2000307 _ $16.60_ 2770320 $42.62 1' IOC 1400310 $52.06 1800310 $19.17 2000310 $1811 _2400307_ 2400310 $47.90 _1 -1/4' _ 12C 1400312 _$72.07 1800312- -- $21.36_- 2000312_ -_ $22.89 -_ - 2400312_ _ -_2 1 -1/2" 15C 1400315 $60.27 1800315 $24.38 2000315 $2430 2400315 $52.23 2 _ 2DC 1400320 $71.2_8 -' 1800320 - $29.67_ 200_0320 _$2_9.26 2400320 $68.20_ 2 -1/2" 25C 1400325 $120.32 1800325 $40.10 2000325 _ $42.36 2400325 $85.46 r 1400330 $134_94 18D0330 $45.72- 2000330_ $46.00 2400330 $143.20 - 1800340 - $76.29 4' 40C 1400340 $202.90 2000340 #65.49 2400340 $164.61 5'- _-SOCu -- 1400_350_ _$312.51 _1800350 v$101.46 2000350 $114.91 2400350 S -, -- - $146.30 2400360 6' 60C 1400360 $336.76 1800360 $13454 2000360 - -_ 8" _ _80C_ 1400380_ _$937.35 1800380_ $394.60 - 2DD0380 S - - - W - 10' 1000 1400390 S 1800390 2 -- 21 -- $ a - it 12' 1200 1400392 - - Q - - - -� ---w .. Q I - ^ 116m MX&Ers listed above. Toll -Free: (800) 654-0320 • TO &Free Fax: (800) 828 -2649 • Nfo@ptcoupfing.oDm • www.ptcoupfiN.can ITEM #88 -- - Pat - Polypropylene Food Brede Pciy Nylon List Price Size I'tern # Ust Item # List Price item # - Item # Name am # Price Item # List Price 314"x 1/2" Name 3/4' _ _07C_ 27003_07_ $8.96 2770307 $10.87 2900307 $11.74 2700310 $10.42 2770310 $11.19 T 2900310 1' IOC - $14.90 L 1 -1/4' _ 12C 3/4'x 1/2' $12.43_ _ _2770312 _ $14.02 _ _- $14.89 1 -1/2' 15C 2700315 $12.14 2770315 $379.11 2900315 $18.21 F 2' 20C 2700320 $li.i67 2770320 $20.80 _$15.43 $15_10 _ 2900320_ 3' 30C 2700330 $26.44 2770330 $25.53 - 2900330 $36.60 -- 4 ^ 40C 2700340 $31.08 2770340 $29.66 2900340 S 116m MX&Ers listed above. Toll -Free: (800) 654-0320 • TO &Free Fax: (800) 828 -2649 • Nfo@ptcoupfing.oDm • www.ptcoupfiN.can ITEM #88 i 3' 30D Alumburm /HBS - - - Aluminum /HB Brass /HB _ _B_rss_s /HBS Item # Size Part List - Item # List am # Ust Price Item # List Price 314"x 1/2" Name 4' -- --- Price 1000440 Price 1070440 $50.42 1200440 $160.90 1290440 EOSD _1000401 $1336 1070401 $14.89 _1200401 $28.51 _ 1290401 $26.81 3/4'x 1/2' 112D 1000405 $1336 1070405 $14.89 1200405 $30.67 1290405 $28.98 1200460 $379.11 S _$13.49_ _1070407 $15.03 _ _ 1200407 $31.80 1290407 $30.11 u _ _ _ 1" 1DD 1000410 $13.80 - $17.26 _ 1070410 _1070412 $15.90 _$1_937_ 1200410 1200412 $35.03 _ $44.91 _ 1290410 _1290412 $32.67 $42_55 L 1 -1/4' _ 12D _ 1000412 1 -1/2" i5D 1000415 $18.55 1070415 $20.66 1260415 $46.99 1290415 $44.62 - 2" `- 20D _ _10004_20 _$20.02 _ _1070420 _ $22.14_ _1200420 $56.83 1290420 $54.45 1 2 -11Y 25D 1000425 $29.43 1070425 $31.54 1200425 $82.32 129D425 i 3' 30D 1000430 $32.19 1070430 $35.82 1200430 $101.22 1290430 $97.15 Price - -- _ - -- - - - -- - -- - -- - -- - -- - _ #46.37_ 1800401 314"x 1/2" PTrn8N6eservenfaies 4' -- --- 40D 1000440 $46.81 1070440 $50.42 1200440 $160.90 1290440 $156.84 i66rarx,� warehouse _ 5 ; SOD 1000450 $83.81 _ _1070450_ _$87.42 _ 1200450 _ $311.13 _ _ 12904_50 $307,Og 11 - _1 kxaGms. 6' 60D 1000460 $11 &13 1070460 $118.13 1200460 $379.11 S '8 4' -8' _ 8DD _ _1000480 _ $445.52 107_0480 $44552 ..1200480.. $1,131.32 _1800450 -2r STA- LOK-posarmb &V HBS cam amsare 10" 1000 1000490 $634.14 1070490 $634.14 1200490 S' - -$ - --- $ --5- -� $ made of 300 series - 12--- - -I20D 1000492 1,527.45 1070492 $1,527.45 S '� $ _ �� 5hf� SteeL Iron Coat Stainle_ Strad Dud size Part Item # list Item # Price Name Price Price _ 1/Y E05D _ 1400401 _ #46.37_ 1800401 314"x 1/2" 112D 1400405 $4639 1800405 l - -3/4" _ 07D _ 1400907 $50.09 _1800407 1" IOD 1400410 $52.46 1800410 1-1/4" _12D- i5D 1400412 1400415 1400420 $66.05 _1800912 18DD415 1800420 1 -1/2" _-$66.05-- $71.30 $76.78 2' 20D 2 -1/2' 25D 1400425 $128.19 1800425 f - 3'- -_ - 30D 1400430 _$14987 _1800430 4' 40D 1400440 $201.94 1800440 5 -6' -- SOD 1400450 $32293 _1800450 -2r STA- LOK-posarmb &V 60D 1400460 $409.67 1800460 �a, - 8DD 100D - 1400480 1400490 $89255_ $1,841.74 1800980 1800490 10" 12' T 1200 140- 002 Iron Coat Alum Carbon Sted HB cam amts are made _.. List -Hard Item # List Price men # List Price of Brass Price Price - $18.64 _ 2000401 $18.68 -- 2400401- - - -- $37.43_ A9Srain(ess Steel rastirgs - -- -S $19.94 2000405 $17.18 21 are 316 and agstandard $20.95 - 2900410 $16;73 IOD MUPWO71S are 300 smies $22.89 2000410 _2400407 _ 2400410 _$47.64 $50.24 SMd-&w leel. _ _ $17.18 $2_3.42_ 2000412 $22.27 2400412 $51.93 $28.61 $32.03 -- - - - Pkase $70.97 �o - $76.74 qre on fe ram amt - - - assemdyandtxvrrparrartts 2000415 2000420 - -- $25.61 $30.58 - - - - 2400415 2400420 - - -- - -- $42.42 _$51.45 _ 2000425 2000430 $3837 _$16.06_ 2400425 2400430_ $88.30 in 316 Sf3in/ess Sleet $124.92 2400440 $63.58 2000440 $69.03 $142.23 8, 10 and 12 i xh oorrplers $106.92 2000450 $12231 24004.50 $26_0.51 are 4-pm desgrrs wi8i the $124.26 _ 2000460 $147.39 a - -2r STA- LOK-posarmb &V $487.86_ 2000480 _ #534.66 _2400480 S J lsahxo. -- a 2000490 a $822.33- 2400490 r - Part - Polypropylene Item # List Price _ Food Grade Item # Paty ILIA Item # LIA Price sine - Name Price - 3/4 - -_ - 07D_ 2700407. - - $8.96 2770407 $12.80 2900407 _$15.63 - $14.00 - 2900410 1" IOD 2700410 $10.42 2770410 #17.85 1_2D _ 2700412 y #12.43 2770412_ $15.93_- 1 -1R" 15D 2700415 $12.14 2770415 $15.65 2900415 $19.23 -_- 2' -- _ D _ 2700420 $14.90- 2770420 ^$14.49_ 2900420 $ -- 3' 30D 2700430 $26.44 2770430 #22.52 2900430 $31.97 ToU-Free: (800) 654-M • ToU-Free Fax: (800) 828.2649 • info@ptcmpUrrg.oDm • www.ptcotOM.caa E- ADAPTER ADAPTER X HOSE SHANK Made in the USA Forbes[ r mft use PUnch-Lok- ceder punc h how danps *0 PT Ga#elg�W�h()&O slraraYs PT hose shards are the most versa* for amgctmw to lase. ThesPe *designed rrzdaharbed shank at" for attadnriend via MOW Rmxh -Lok- oanWWxh denies (see pg. 115 for mm detak), or by an cdarlorked Pro&O" P50 femrle Of SWM (see pgs. 95-100 for mm abfmb). A# &Wess S19W MsMX are 316. A#1- 1,7to6 Ahamrwma Hard Coal Mm#wrn casWW are ava#ade w#h Undersized shank. To order adi the letters 'US'a#er the exisft ftem nlmlbers listed above. _ size 1R - ' -- 3/4'x 1/2' 314' 1' _ Part Name EOSE - I/2E _ 07E l0E aumhnan Itern # - 1000501 -w - - 1000507 1000510 _ - UFst Price ;734 - -$ - _ $7.29 $7.34 B_ras_s Item # 1200501 _ 1200505 _ 1200507 1200510 Part # $16.19 $16.94- $1731 $20.41 Stainless_ hem # 1400501 - 1400505 1400507 1400510 Steel I ` - - -_- List Price Size ;33.95 1/2' - - - a 3/4 "x 1/2' $32.29 3/4' $34.94 1' - Part Name E05F - 1/2F 07F _ Aluminum Item # 1000601 - - -_- 1000605 1000607 -- List Price $5.17 -- $9.84 - -$6.62 $8.22 _ Brass R m # 1200601 - - 1200605 1200607 1200610 List Price $12.04 -- $15.95 $14.14_ _ $14.46 IOF 1000610 -_ 1 -1/4' 12E - 1000512 $9.70 1200512 $29.96 1400512 $46.05 ( 1 -114' $999 . - 1200612 $33.82 12F 1000612 1-112' -- 1SE - - 1000515 $9.67 1200515 -- $33.06 - 1400515 $43.58 1 -1/2" 15F 1000615 $10.77 1200615 $33.82 2' 20E- 1000520 $12.04 1200520 $51.38 1400520 $42.03 2- 2OF 1000620 $12.18 - 1200620 $.30.91 $ 2 -1/2' 25E 1000525 $19.03 1200525 $78.06 1400525 - $106.11 2 -1/2 25F 1000625 $21.58 1200625 .. $79.74 _ -3' -- - - - 30E _ 1000530 $21.14 _ _ 1200530 _ $8035 1400530 _- $8034 -� �- -_3' 30F _- 1000630_ $23.64 120W30 $92.52 -- 4" 40E 1000540 $4256 1200540 $139.57 1400540 _ $184.92 4- 40F 1000640 $43.16 1200640 $126.59 5- -6' 50E _ - 1000550_ - $68_69 _ -- _50 _12005 $22 5.05_ - 1400550_ _ $293.48 5' SOF _ _1000650_ _ $55.53- - 1200_650_ $247.32 1.112' 1 60E 1000560 $84.00 1200560- $364.63 1400560 _ $361.43 6- 60F 1000660 $96.44 1200660 $355.51 8' -- - -SOE - -- 1000580 - -- $416.81 1200580 $833.91 - 1400580 $816.72 i 8' BOF 1000680 $281.81 1200680 $780.56 10' 100E 1000590 $715.84 2400620 - - $62.26 ) 1400590 9 10' 100F 1000690 $376.39 1200690 S j 12' 120E 1000592 $1,566.71 >i 't; $30.80 2 '$ 12' 120E 1000692 $1,319.92 Q ! Stainless Sted Item # List P _ 1400601 $35. 1400605 $39. _1400607 _ _ $36. 1400610 $90. 1400612 $54. 1400615 $55. F- ADAPTER ADAPTER X MALE NPTTHREAD --� Made In the USA 1400620 $57.231, J 1400625 $110 1400630 $113 1400640 $181 1400650 $257 1400660 $333 1400680 $829 1400690 8 .3 Jr.-jw- m nr _. PT [nanta/ns imammes at its _ 16darrhWarehouse Amabim6 --- - - - -- - -- - - - - - -- -- --�- ----- - - -- - -- �I _ - - - - - -- Ductile - _ - - Iwra cant aum _- - - Carbon Sled . Size - Part Name I Item # P Part # - Items P Part # I Item # L List Price s _ -- - - Part Nance I Item # P Part # I Item # L List Price I Item # L List Price EOSE 1 1600501 $ $10.48 2 2000501 $ $11.95 2 2400501 $9.91 I I I 1R" E EOSF 1 1800601 $ $10.57 2 2000601 - - $11.16 2 2400601 $ $9.99- _ 3/4'x 1/2' 1 1/2E w w S S s s 9 9 S S i it 3 3/4'x 1/2" 1 1/2F 1 1800605 $ $10.57 2 2000605 $ $10.56 2 2400605 . .$9.99 3/4' - -- - - _07E. - - -- 1 1800507 $ $12_80 2 2000507 _,- _ _$11.95 _ _ $12.11 _/ 3/4' - _ _ 07F -_- - - 1800607 $ $10.57 - _ _2000607 - - $99.99 _ 2 24006_07 $ $9.99 _ 1 1' l l0E 1 1800510 $ $13.50 2 2000510 $ $12.24 2 2400510 $ $12.76 1 1' I IOF 1 1800610 $ $11.89 2 2000610 $ $11.97 2 2400610 $ $11.24 1 -1/4' _ _ _ 12_E _ 1 1800512 _ _ $14.53_ 2 2000512 $ $14.88 2 240051_2 - 1 -1/4' 1 12F _ 1800612 ; ;15.51 2 2000612 ; ;13.21 2 2400612 $ $48.63_ 1.112' 1 15E 1 1800515 $ $14.66 2 2000515 $ $17.65 2 2400515 $ $38.01 1 -- 1 _ 1 1800615 $ $15.77 2 2000615 $ $19.10 2 2400615 $ $51.47 I_ 2- 2 20E 1 1800520 - $1 &57 - 2000520 _ _ $ $19.26 _ - 2400520 $ $42.35 Y Y ` `, - 1800620 $ $19.46 2 2000620 $ $21.88 2 2400620 - - $62.26 ) 2- 1/2' 2 25E 1 1800525 $ $34.99 2 2000525 $ $30.66 2 2400525 $ $70.27 2 2 -1/2' 2 - -- 2 1800625 $ $26.60 2 2000625 $ $30.80 2 2400625 $ $73.31 3' 3 30E _ _1800530 $ $26.40 _ _ 2000530 $ $3695 _ _2400530 $ $90.25 -..I ` `- _3' 3 3OF _ _ 1800630 $ $36.95 2 2000630 $ $34.15 _ _ _ 2400630 _ _ _ $102.92 4' 4 40E 1 1800540 $ $50.07 2 2000540 $ $62.51 2 24OD540 $ $134.18 4 4' - OF 1 1800640 $ $56.90 - 2000640 - $112.69 2 2400640 $ $113.40 5' - S SOE 1 1800550 $ $83.57 2 2000550 $ $94.68 ` `it a a t t 5' S SOF 1 1800650 $ $82.40 2 2000650 $ $146.06 S S 9 9 6" 6 60E 1 1800560 $ $110.31 2 2000560 $ $121.19 2 2400560 a a 6 6' 6 60F 1 1800660 $ $110.02 2 2000660 $ $130.16 2 2400660 $ $30635 8" _ _ 8DE _ 1 1800580 _ $ $391.34 2 2000580 a a w w _ 2 2 ) ) .._ 8' 8 80F 1 1800680 _ _ _ $279.25_ _ _ 2000680 2 . . - - _-- - - -. . -- 10' 1 100E S SBD0590 - ! - $ - '$ $ $. 10" . 100E - 1800690 S S^ ' 'B 9 9 2 21 7 73 l _ 12' -_ 1 120E : : _ _ 2 S S _ w w ' '@ I I 12' _. _ _ 120E Nylon _ I P Polypropylene F Food Grade Poly N Nylon J Food Grade Poly N Site P Part Name I Ilan # P Part # I Item # P Part # I Item # L List Price S Size P Part Name I Item # P Part # I Item # L List Price I Itan # L List Price 3/4 "- 0 07E 2 2700507 _ $ $3.66 _ _ 2770507 $ $6.10 - 2 2900507 $ $4.86 3 3/4' - 0 07F _ _ _ 2700607 $ $3.73 2 2770607 $ $6.98 2 2900607 _ _ $10.42 -I 1' W WE 2 2700510 $ $4.08 2 2770510 $ $6.38 2 2900510 $ $5.60 1 1' 1 1DF 2 2700610 $ $4.12 2 2770610 $ $7.78 2 2900610 $ $8.72 1 -1/4' 1 12E _ 2 270' - $ $4.69 _ _ _ 2770512 _ _ $6.86 - - _ _ _ _ '� _ _ 1 -1/4' . _ . - - - -- _ 12F _ _ - _ __ 2700612 $ $4.78 2 2770612 _ - - _ $7.80 2 2900612 _ _ _ - _$9.42 _ 1 -1/2' I ISE 2 27DDS15 $ $5.03 2 2770515 $ $7.26 2 2900515 $ $7.61 1 1 -1/2" 1 15F 2 2700615 $ $5.26 2 2770615 $ $7.34 2 2900615 $ $6.98 �- 2" _ _20E_ _ _ _ 2700520 $ $6.26 2770520 $8.42 2900520 $ $8.67.T_� _ __- 2' -- _ __ 2OF _ _ _2700620_ _ __ 7.24_ 2 2770620 _ _ $8.42_._ 2 2900620 $8.11__9 3' 3 30E 2 2700530 - $13.79 2 2770530 $ $14.32 2 2900530 _ ;14.92 3 3' 3 3DF 2 2700630 $ $15.76 2 2770630- - $16.49 2 2900630 $ $17.67 I -.. -4-', - To0-Free: (800) 654-OM • Ta8-Free Fax: (BDO) 828-2649 • info@ptcmong.00m • www.ptcoupthg.cam ToUree: (8001654-M - To0-Frea Fax: (800) 828 -2649 • Udo@ptcoupfing.com • www.ptcoupfing oom V-COUPLER DUSTCAP Made In ft U.SA AS 16 bwch Nanftm tcaum HBS cam an are made of 300 series SLqMbW Steel HB cam amts are made of Brass. A#&wA,ss&wfwshrW are 316 and ag covipormts are 300 series SUvdess Steel Please call for VacW (We on ­We ca, am assw* and canporw& m 316 SMffdess Steel. 8, 10 and 12 inch wWlms are 4-carn designs *iffi #w STA-L0X-pos*wbddng feaftre C_ _ size _ part L 1/2.E05V 3/4- 07V I. lav 1-1/4- IZV ciw _I5V 2' 20V ii _25V 3' 30V 49V 5' 50v 6'__ 6(YV-' , 10" _10DV 12*_ -1 120V stawess Steel Adiw mn IHBS Akunfn=/HB Alum Bratss/RB Bern # Brassi Size Part Itefn# UstPricie Imo List item # List Price `tern # 2001101 Name a 2401107 K01101 K01107 Price 1801107 $13.82 2001107 1/2' - -EO-5V- 100 1101 $-1-2.04- -1071-101- $13.58 - 1201101 - - -$22-.-53 -12-9110-1 3/4- 07V 1001107 $13.55 1071107 1071110 1071112 $15.13 $16.01_ $18.61 1201107_ 1201110_ 1201112 _$29.53 $M53- $36.74 1291107 1291110 14410V _$19.67 $23.04 1001110 $13.89 1 12V_ _1001112 $16.49 1291112 1-1-1/2-. 1401125 1001115 $17.12 1071115 $19.24 _1201115_ $43.21 1291115 2' --ISV-- 20V 1001120_ $17.68 1071120 $1930 1201120 $47.76 1291120 F2-11-2' - 2-5-V -1001125 $2254 1071125 $24.16 1201125 $46.46 1291M $27.05 1201130 3' 30V 1001130 $23.44 1071130 $70.18 1291130 rr 4 40V 1001140 $32.15 1071140 $35.76 5 1201140 $98.20 1291140 5. 50V 1001150 $54.01 1071150 $57.62 1201150 $226.19 It $81.46.- 1071160 $8-.46- $248.03 ir _60V-1001160- 80V 1001180 $270.64 1071180 $270.64 1201180 $631.81 a IT lWV -1-00I190 _$526-.60 _ 1071190 $526.60 _1_2,0_1190_ it w 12- 12UV 1001192 $1,436.05 1071192 $1,436.05 2 a 9 C_ _ size _ part L 1/2.E05V 3/4- 07V I. lav 1-1/4- IZV ciw _I5V 2' 20V ii _25V 3' 30V 49V 5' 50v 6'__ 6(YV-' , 10" _10DV 12*_ -1 120V stawess Steel Ductile Iron Hard Cod Alum Carbe Bern # List Price Itern # List Finn # List Price Item # $10.87 $45.79 1801101 Price $12.54 2001101 $14.53 $14.68 a 2401107 K01101 K01107 $41.54 1801107 $13.82 2001107 K01110 $46.95 _1801110 $15.42 2001110 $17.52 2461110 K01112 $53.37 $14.90 -1-2771120-1 $18.52 2001112 2901120 a 1401115_ $58.10 _1801112 1801115 $22.11 2001115_ _$19.67 $23.04 2401115 �401120 $68755 1801120 $25.81 2001120 $23.48 2401120 1401125 __$110.00 _18011B__$33.10__200I125 60800050 _ $78.39 6 $30.25 2401125 2401130 K01 UD $87.33 1801130 $35.96 2001130 $34.48 401140 $129.96 _1801140 _$52.99 - 2001140_ _$229 2401140 401150 $251.95 1801150 $78.73 2DO1150_ $72.29 f401160 _A3WO $855.4i- 1801160 __,8&Imo $94.98 $441.48- 2001160 2001180 - $118.16 $507.99 , - 2401160 2401180 A01180 40119 1801190 � ili It 40119 I801192 ___W_ 2 s w It Size 3/4* Part Kam 07V Item # 2701107 List Price $8.96 Food Grade Ibern Poly List Price $9.04 Nylon Itern # 2901107 List Price $11.67 2771107 1" JOV 2701110 $9.90 2771110 $10.87 2901110 $13.56 - _ 15A _ - JZV 2701112 $10.16 -$12-.14- 2771112 $13.52 - - -$17.5-3--- -2771-1-15- -$15.23 2-90111-5 -1--1/4-- 1-1/2- 15V ;bm-, 1-5 $133.35 2-1/2- 2 r 2(YV 2701M $14.90 -1-2771120-1 $87.56 6 $19.91 2901120 $20.94 3' 3(YV 2701130 $23,32, 2771130 $26.48 $152.84 $28.45 4' 49V 2701140 1 $31.03 2771140 $29.50 2901140 _$33.13 TaFree: (M) &14-0W) • ToUcee F= (800) 82&2649 • intoWcWmgoom • www.ptouqfiN.mm �TB=s List Price $20.84 $_2715 -$3-4.14_1 $3437 _$40.83 $45.38 $66.12 $94.15 steel List Price $32.48 $60.69 $74.73 $94.89 a $26413. 60VL 60800060 $129.97 62850066 $303.24 64600060 Ductile Iron *Hard Coat Alum Stie Part Nam Item # List Price ItErn # List Price Itern # List Price 11-4q,_ __15_A ---- 68800020 a , _47 2' 2(1VL $41.67 70800020 $35.87_ 67800020 2-112- -25A - _68800025 - - $43.69 0025 _$42.47 Y 30VL 68800030 $51.02 70MM O It 67800030 - 68800040 $70.66 70800040 S 67800D40_ 5' 50VL 1_68800050 $11015 It 9 512850 70800060 $120.47 60VL 6BBDDD60 with b= cam arms Dust caX with Bass can Alms m pwad w0fad p mp *'Pdwd with 316 stm* and 300 series pin and 4V. I- 'Ir 8W r dust Caps with StgN= cam Alms am prod wO Pu# fmp 2f2'a,?db,WdWc.pSw,ffi&Rud m.Alms&spe'�edklWpdwgs Pct rigs m nN wbd8dw Ow 4, A and 6mxh Bass )a Lodiv Can Amfl6y- 316 Stainless Sted Cast Brass CaWler Size Part Name Item # List Price Item # List Price & 2-1/2 20)(1. 5OD4020A $22.10 500352G2 $10.24 31 30)CL 5OD403CIA $27.13 5003530A $13.51 4'_ 40)(-L 5-0-0-4030A- _--$27.13 5003540A $-16.02 5. 50)a. - 5003550A $26.92 6' 60n - 50035160A $310 I 316 SGiJSS Steer cam ems mme sladad with 360 series per ad req. PufffuW Ale nol kxkAded in ft 4,5, and 6 we Bass A LoddV Cam Ass&nbfy. SS ChainW /Hooks SS Chain W/Rings Size Part Name Item # List Price Ibern # List Price 5-5-6- 5101060A - Wi- 51-01-06 -1A - S51_____ 5101080A $4.44 5101081A_ 552 5101092A $5.65 5101093A vsks Brass Chain _W /Hooks Brass ChainW /Rhrgs size Part Nam I List Price List Price .6- C51 5, $2.12 8. L_12_ - -_ C52 5100592A $166 5105592A _$2 cl- Chaiz can aisobe mferWto aww k%ft, BA Chwn z afro avOabfa Please Cad for pnciV and ava#aWty. VL-COUPLER DUST CAP WILOCKING CAM ARMS Made in 1W U.SA XL LOCKING CAM ASSEMBLY FOR VL COUPLER 1 CAM ARM, I PIN& I PULL RING Made in the USA SECURrrY CHAINS FOR DUST CAPS & DUSTPLUGS Made in the USA To8-Free:(800)654-M • T&FfeeFax: (8W)L18-2649 • inio@ptcoLpthig.com • www.pm#tM.com -stainimsted Size P Part Name I Item # L List Price I Item # L List Price I Item # L List Price 1-1/2- - - I - - _ 15A _ - 60800015 I5 v 6 628DD015 i it 12 6 2 1 2' 2 - _ 60800020 $ $33.08 6 62800020 $ $6410 _ $133.35 2-1/2- 2 25A 6 6DMM25 $ $34.69 6 6280M $ $87.56 6 _648D0020 $ $138.46 3' 3 30VL 6 60800030_ $ $39.20 6 62800030 $ $106.06 6 64800030 $ $152.84 4' F- 40VL 60800040 _ _ $56- 52 6 62800040 - _ _$170. 40 6 64800040 - _-_ - - -$-18- 9- - .92 T 1 50VL 6 5' 5 60800050 _ $78.39 6 628ODM _ i Ductile Iron *Hard Coat Alum Stie Part Nam Item # List Price ItErn # List Price Itern # List Price 11-4q,_ __15_A ---- 68800020 a , _47 2' 2(1VL $41.67 70800020 $35.87_ 67800020 2-112- -25A - _68800025 - - $43.69 0025 _$42.47 Y 30VL 68800030 $51.02 70MM O It 67800030 - 68800040 $70.66 70800040 S 67800D40_ 5' 50VL 1_68800050 $11015 It 9 512850 70800060 $120.47 60VL 6BBDDD60 with b= cam arms Dust caX with Bass can Alms m pwad w0fad p mp *'Pdwd with 316 stm* and 300 series pin and 4V. I- 'Ir 8W r dust Caps with StgN= cam Alms am prod wO Pu# fmp 2f2'a,?db,WdWc.pSw,ffi&Rud m.Alms&spe'�edklWpdwgs Pct rigs m nN wbd8dw Ow 4, A and 6mxh Bass )a Lodiv Can Amfl6y- 316 Stainless Sted Cast Brass CaWler Size Part Name Item # List Price Item # List Price & 2-1/2 20)(1. 5OD4020A $22.10 500352G2 $10.24 31 30)CL 5OD403CIA $27.13 5003530A $13.51 4'_ 40)(-L 5-0-0-4030A- _--$27.13 5003540A $-16.02 5. 50)a. - 5003550A $26.92 6' 60n - 50035160A $310 I 316 SGiJSS Steer cam ems mme sladad with 360 series per ad req. PufffuW Ale nol kxkAded in ft 4,5, and 6 we Bass A LoddV Cam Ass&nbfy. SS ChainW /Hooks SS Chain W/Rings Size Part Name Item # List Price Ibern # List Price 5-5-6- 5101060A - Wi- 51-01-06 -1A - S51_____ 5101080A $4.44 5101081A_ 552 5101092A $5.65 5101093A vsks Brass Chain _W /Hooks Brass ChainW /Rhrgs size Part Nam I List Price List Price .6- C51 5, $2.12 8. L_12_ - -_ C52 5100592A $166 5105592A _$2 cl- Chaiz can aisobe mferWto aww k%ft, BA Chwn z afro avOabfa Please Cad for pnciV and ava#aWty. VL-COUPLER DUST CAP WILOCKING CAM ARMS Made in 1W U.SA XL LOCKING CAM ASSEMBLY FOR VL COUPLER 1 CAM ARM, I PIN& I PULL RING Made in the USA SECURrrY CHAINS FOR DUST CAPS & DUSTPLUGS Made in the USA To8-Free:(800)654-M • T&FfeeFax: (8W)L18-2649 • inio@ptcoLpthig.com • www.pm#tM.com with b= cam arms Dust caX with Bass can Alms m pwad w0fad p mp *'Pdwd with 316 stm* and 300 series pin and 4V. I- 'Ir 8W r dust Caps with StgN= cam Alms am prod wO Pu# fmp 2f2'a,?db,WdWc.pSw,ffi&Rud m.Alms&spe'�edklWpdwgs Pct rigs m nN wbd8dw Ow 4, A and 6mxh Bass )a Lodiv Can Amfl6y- 316 Stainless Sted Cast Brass CaWler Size Part Name Item # List Price Item # List Price & 2-1/2 20)(1. 5OD4020A $22.10 500352G2 $10.24 31 30)CL 5OD403CIA $27.13 5003530A $13.51 4'_ 40)(-L 5-0-0-4030A- _--$27.13 5003540A $-16.02 5. 50)a. - 5003550A $26.92 6' 60n - 50035160A $310 I 316 SGiJSS Steer cam ems mme sladad with 360 series per ad req. PufffuW Ale nol kxkAded in ft 4,5, and 6 we Bass A LoddV Cam Ass&nbfy. SS ChainW /Hooks SS Chain W/Rings Size Part Name Item # List Price Ibern # List Price 5-5-6- 5101060A - Wi- 51-01-06 -1A - S51_____ 5101080A $4.44 5101081A_ 552 5101092A $5.65 5101093A vsks Brass Chain _W /Hooks Brass ChainW /Rhrgs size Part Nam I List Price List Price .6- C51 5, $2.12 8. L_12_ - -_ C52 5100592A $166 5105592A _$2 cl- Chaiz can aisobe mferWto aww k%ft, BA Chwn z afro avOabfa Please Cad for pnciV and ava#aWty. VL-COUPLER DUST CAP WILOCKING CAM ARMS Made in 1W U.SA XL LOCKING CAM ASSEMBLY FOR VL COUPLER 1 CAM ARM, I PIN& I PULL RING Made in the USA SECURrrY CHAINS FOR DUST CAPS & DUSTPLUGS Made in the USA To8-Free:(800)654-M • T&FfeeFax: (8W)L18-2649 • inio@ptcoLpthig.com • www.pm#tM.com 316 SGiJSS Steer cam ems mme sladad with 360 series per ad req. PufffuW Ale nol kxkAded in ft 4,5, and 6 we Bass A LoddV Cam Ass&nbfy. SS ChainW /Hooks SS Chain W/Rings Size Part Name Item # List Price Ibern # List Price 5-5-6- 5101060A - Wi- 51-01-06 -1A - S51_____ 5101080A $4.44 5101081A_ 552 5101092A $5.65 5101093A vsks Brass Chain _W /Hooks Brass ChainW /Rhrgs size Part Nam I List Price List Price .6- C51 5, $2.12 8. L_12_ - -_ C52 5100592A $166 5105592A _$2 cl- Chaiz can aisobe mferWto aww k%ft, BA Chwn z afro avOabfa Please Cad for pnciV and ava#aWty. VL-COUPLER DUST CAP WILOCKING CAM ARMS Made in 1W U.SA XL LOCKING CAM ASSEMBLY FOR VL COUPLER 1 CAM ARM, I PIN& I PULL RING Made in the USA SECURrrY CHAINS FOR DUST CAPS & DUSTPLUGS Made in the USA To8-Free:(800)654-M • T&FfeeFax: (8W)L18-2649 • inio@ptcoLpthig.com • www.pm#tM.com VL-COUPLER DUST CAP WILOCKING CAM ARMS Made in 1W U.SA XL LOCKING CAM ASSEMBLY FOR VL COUPLER 1 CAM ARM, I PIN& I PULL RING Made in the USA SECURrrY CHAINS FOR DUST CAPS & DUSTPLUGS Made in the USA To8-Free:(800)654-M • T&FfeeFax: (8W)L18-2649 • inio@ptcoLpthig.com • www.pm#tM.com Mechanical Line Leak Detector For use with 4" STPs, the MLD product line is precision built, with unique construction features that provide busy stations with maximum flow rates and long service life. The MLD is offered in three models to match your exact application, ensuring accurate, nuisance -free operation critical to profitable station operation. RLL• 71429tuelz THERMAL CON COMPENSATIO Specifications: • Three models: STP -MLD (blue) for gasoline, STP -MLD -D (tan) for diesel and STP -MLD -E (grey) for some expandable pipe applications. • Solid brass piston has 1 -5/8" of travel to move the leak detection poppet fully out of the flow, offering minimum flow restriction and maximum flow rates. • Burnished brass cylinder liner and polished stainless steel piston rod ensure smooth operation and long life from the Teflon seal. • Thermal compensation chamber of 5 -3/4 cubic inches helps minimize thermal contraction nuisance tripping. Liquid Compatibility • Max. liquid viscosity: 70 SSU at 60 °F (15 °C). • STP -MLD and STP -MLD -E models are compatible with fuel mixtures containing up to 100% ethanol or methanol, and 20% MTBE, 20% ETBE or 17% TAME with gasoline, as well as diesel fuels, fuel oils, kerosene, Avgas and jet fuels. • STP -MLD -D models are listed for diesel fuels or kerosene only. 24 ITEM #95 s s • All models are capable of detecting line leaks equivalent to 3 gph at 10 psi when installed properly with the appropriate fuels. All models will signal detection of leaks by restricting product delivery to less than 3 gpm and taking more than 4 seconds to open. • All models require 2 to 3 seconds to make a line test when no line leaks BURNISHED BRASS exist and air is purged from piping CYLINDER LINER between the discharge of the MLD TEFLON SEAL and the dispenser solenoid. • All models will remain in the `open" position during product delivery to TEFLON SEAL manifold, with discharge pressures as low as I psi. All models will reset to the "tripped" when line pressure delay is below 3 psi with pump off. • All models will detect leaks up to 10 feet above the MLD installation point. GROUND AND j POLISHED STAINLESS STEEL I C US LISTED PISTON ROD fi F Approvals • Third party certified to comply with US EPA requirements 280.41 (B) and 280.44 (A) for continuous monitoring of pressurized piping. • Consult factory for other applicable approvals. Quality Certification • Franklin Fueling Systems is an ISO 9001 Certified Manufacturer. N n 0 n 0 � 'ttoo kJ O O a. Description 400500903 STP -MLD for gasoline 400501903 STP -MLD -D for diesel or kerosene 400502903" STP -MLD -E for expandable piping 400503903 COMBO, contains two STP -MLDs and one STP -MLD -D eo � n t Mechanical Line Leak Detector (for use with 4" STPs)` Single Pack Part Number Description 400500901 STP -MLD for gasoline, blue 400501901 I STP -MLD -D for diesel or kerosene, tan 400502901° STP -MLD -E for expandable piping, grey Three Pack Part Nur6ber Description 400500903 STP -MLD for gasoline 400501903 STP -MLD -D for diesel or kerosene 400502903" STP -MLD -E for expandable piping 400503903 COMBO, contains two STP -MLDs and one STP -MLD -D Notes: I. MILD and MLD -E models are compatible with fuel mixtures containing up to 100% ethanol or methanol with gasoline, diesel fuels, and 20% MTBE, 20% ETBE or 17% TAME with gasoline. 2. MLD -D models are listed for compatibility with diesel fuels and kerosene applications only. 3. All above models will only mount in the 2" NPT leak detector port of a 4" submersible turbine, including competitive models, or in a leak detector adapter tee (sold separately below). 'Designed for limited flexible piping systems with low bulk modulus, consult factory before ordering. 'Refer to STP -MLD installation manual for complete compatibility specifications. MLD Repair Parts and Accessories 400440101 MILD vent tube 400449901 MLD hardware pack, fittings and documentation 400518001 Leak detector adapter tee SYP TANK POF (VENTTUI CONNEC' )RT 25 Single -Phase Control Box The FE Petro standard single -phase control box latches line power to the submersible when the relay is energized by a dispenser signal. Compatible with FE Petro and competitive makes of single - phase, fixed speed submersible turbines up to 2 hp. Part Number Description STP-CBS, single -phase control 400818921 box, with switch and lockout, 120Volt coil STP -DHI -CBS, combo 402313921 dispenser hook isolation with factory wired STP -CBS Notes: I. CBS models are compatible for use on all single -phase FE Petro submersibles and competitive makes. 2. One CBS required per submersible, relay rated for 30 Amps up to 2 hp. 3. Incorporates pump "ON" indicator light 4. Relay rated for 220 Volt pumps up to 2 hp, 30 Amps. STP -CBS Repair Parts and Accessories 8 1 2 0 7 7 3 4 5 6 30 ITEM #96 9 Advantages • Incorporates an "ON /OFF" lockout switch. o • Relay energized with 110 Volt dispenser /hook signal. • Franklin Fueling Systems is an o ISO 9001 certified manufacturer. • Consult factory for applicable approvals. C UL US LISTED N Part Number I Description 1 400575001 Power switch for CBS and CBBS models 2 400574001 Power switch bracket 3 400158901 Light assembly, 120Volt 4 400215931 Relay, 30A, 120 Volt coil 5 400278005 Six position terminal strip 6 402410001 CBS terminal strip label 7 400817901 Cover and enclosure 8 400819001 CBS wiring diagram 30 ITEM #96 9 Advantages • Incorporates an "ON /OFF" lockout switch. o • Relay energized with 110 Volt dispenser /hook signal. • Franklin Fueling Systems is an o ISO 9001 certified manufacturer. • Consult factory for applicable approvals. C UL US LISTED N SWRCB, January 2002 Secondary Containment Testing Report Form Page of This form is intended for use by contractors performing periodic testing of UST secondary containment systems. Use the appropriate pages of this form to report results for all components tested. The completed form, written test procedures, and printouts from tests (if applicable), should be provided to the facility owner /operator for submittal to the local regulatory agency. 1. FACILITY INFORMATION Facility Name: COSTCO 688 1 Date of Testing: 6/24/2013 Facility Address: 3800 ROSEDALE HIGHWAY, BAKERSFIELD,CA Facility Contact: LISA I Phone: 661 - 636 -0822 Date Local Agency Was Notified of Testing: 6/21/2013 Name of Local Agency Inspector ("(present during testing): ERNIE MEDINA 2. TESTING CONTRACTOR INFORMATION Company Name: Jones Covey Group, Inc. Pass Technician Conducting Test: Frank Vasquez Not Tested Credentials: 9 CSLB Licensed Contractor ❑ SWRCB Licensed Tank Tester License Type: A, B and Haz License Number: 804431 Manufacturer Manufacturer Trainine Component(s) Date Training Expires INCON TS -STS 1/24/2015 ❑ ❑ ❑ ❑ ❑ 3. SUMMARY OF TEST RESULTS Component Pass Fail Not Tested Repairs Made Component Pass Fail Not Tested Repairs Made T -1 87 FILL SUMP IS ❑ ❑ ❑ ❑ ❑ ❑ ❑ T -2 87 FILL SUMP g ❑ ❑ ❑ ❑ ❑ ❑ ❑ T -3 91 FILL SUMP ❑ ❑ ❑ ❑ ❑ ❑ ❑ ADDITIVE TRANSITION SUMP 19 ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ 1 ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑. ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ If hydrostatic testing was performed, describe what was done with the water after completion of tests: WATER WAS PLACED INTO 55 GALLON POLYDRUMS WITH DECALS FOR PROPER DISPOSAL. CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING To the best of my knowledge, the facts stated in this document are accurate and in full compliance with legal requirements Technician's Signature:_ Date: 6/24/2013 SWRCB, January 2002 6. PIPING SUMP TESTING Page of Test Method Developed By: L Sump Manufacturer ❑ Industry Standard ❑ Professional Engineer ❑ Other (Spec) Test Method Used: ❑ Pressure ❑ Vacuum 9 Hydrostatic ❑ Other (Spec) Test Equipment Used: INCON TS- STS Sump # Additive trai Sump # N/A Equipment Resolution: +/- 0.0001" Sump # N/A Sump # N/A Sump Diameter: 30" Sump Depth: 32" Sump Material: Flberglass Height from Tank Top to Top of Highest Piping Penetration: 8„ Height from Tank Top to Lowest Electrical Penetration: N/A Condition of sump prior to testing: DRY Portion of Sump Tested' 2" Above Highest Per Does turbine shut down when sump sensor detects liquid (both product and water)?* R Yes ❑No ❑ NA ❑ Yes ❑ No X NA ❑ Yes ❑ No A NA ❑ Yes ❑ No A NA Turbine shutdown response time Is system programmed for fail -safe shutdown ?' kl Yes ❑No ❑ NA ❑Yes ❑ No ANA ❑ Yes ❑ No 19 NA ❑ Yes ❑ No ANA Was fail -safe verified to be @ Yes ❑No ❑ NA ❑ Yes ❑ No A NA ❑ Yes ❑ No ® NA ❑ Yes ❑ No A NA -operational?* Wait time between applying pressure /vacuum /water and starting test: 15 MINUTES Test Start Time: 3:01 3:35 Initial Reading (R,): 5.5867 5.5871 Test End Time: 3:16 3:50 Final Reading (RF): 5.5874 5.5870 Test Duration: 15 Min(each) 30 Min Change in Reading (RF -R,): 0.0007 0.0001 Pass /Fail Threshold or Criteria: +/- 0.002" Test Result: ® Pass ❑ Fail ❑ Pass ❑ Fail ❑ Pass ❑ Fail. ❑ Pass ❑ Fail. Was sensor removed for testing? k Yes ❑No ❑ NA ❑ Yes ❑ No 9 NA ❑ Yes ❑ No A NA ❑ Yes ❑ No ® NA Was sensor properly replaced and verified functional after testing? F yes ❑No ❑ NA ❑Yes ❑No C�NA ❑Yes ❑No MINA ❑ Yes ❑No ANA Comments — (include information on repairs made prior to testing, and recommended follow -up for failed tests) ' If the entire depth of the sump is not tested, specify how much was tested. If the answer to Aanu of the questions indicated with an asterisk ( *) is "NO" or "NA ", the entire sump must be tested. (See SWRCB LG -160) SWRCB, January 2002 8. FILL RISER CONTAINMENT SUMP TESTING Page of Facility is Not Equipped With Fill Riser Containment Sums ❑ Fill Riser Containment Sumps are Present, but were Not Tested ❑ Test Method Developed By: ❑ Sump Manufacturer X Industry Standard ❑ Professional Engineer ❑ Other (Specie) Test Method Used: ❑ Pressure ❑ Vacuum -X Hydrostatic ❑ Other (Spec) Test Equipment Used: INCON TS- STS Equipment Resolution: +/- 0.0001" Fill Sum # T -1 Fill Sump # T -2 Fill Sump # T -3 Fill Sum # N/A Sump Diameter: 48" 48" 48" 48" Sump Depth: 67" 66" 64" Height from Tank Top to Top of Highest Piping Penetration: 28" 30" 33" Height from Tank Top to Lowest Electrical Penetration: 36" 34" 30" Condition of sump prior to testing: DRY DRY DRY Portion of Sump Tested 2" Above Highest Per 2" Above Highest Pe 2" Above Highest P Sump Material: Fiber lass Fiber lass Fiberglass Wait time between applying pressure /vacuum/water and starting test: 15 MINUTES 15 MINUTES 15 MINUTES Test Start Time: 12:08 12:51 1:11 1:30 2:16 2:36 Initial Reading Rj): 6.5056 6.5052 3.2770 3.2765 5.0894 5.0887 Test End Time: 12:23 1:06 1:26 1:45 2:31 2:51 Final Reading RF ): 6.5054 6.5052 3.2767 3.2762 5.0888 5.0886 Test Duration: 15 Min each 30 Min 15 Min each 30 Min 15 Min each 30 Min Change in Reading RF -R, : 0.0002 0.0000 0.0003 0.0003 0.0006 0.0001 Pass /Fail Threshold or Criteria: +/- 0.002" +/- 0.002" +/- 0.002" Test Result: ® Pass ❑ Fail ® Pass ❑ Fail 19 Pass ❑ Fail ❑ Pass ❑ Fail Is there a sensor in the sump? X Yes ❑ No X Yes ❑ No X Yes ❑ No ❑ Yes ❑ No Does the sensor alarm when either product or water is detected? E Yes ❑No ❑ NA X Yes ❑ No ❑ NA X Yes ❑ No ❑ NA ❑ Yes ❑ No X NA Was sensor removed for testin�and 10 Yes ❑No ❑ NA X Yes ❑ No ❑ NA X Yes ❑ No ❑ NA ❑ Yes ❑ No X NA Was sensor properly replaced verified functional after testin W Yes ❑No ❑ NA X Yes ❑ No ❑ NA X Yes ❑ No ❑ NA ❑ Yes ❑ No X NA Comments — (include information on repairs made prior to testing, and recommended folloly -up for failed tests) TESTING WAS PERFORMED DUE TO NEW ADDITIVE PRODUCT PENETRATIONS INTO EXISTING FILL SUMPS. 1 COSTCO 688 3800 ROSEDALE HWY 3800 ROSEDALE HVY COSTCO 688 BAKERSFIELD,CA 3800 ROSEDALE HWY 1- 800 -984 -6266 CONTAINMENT BAKERSFIELD,CA V ME ERR 1- 800 - 984 -626: CONTAINMENT 6/21/2007 XLOOOO 1- 800 -984 -6266 0000 IN 06/21/2007 12:08 AM SHOLD 0, 04 IN T -IFILL LT OR 06/21/2007 1:06 AM SUMP LEVEL REPORT T -2FILL BEGIN LEVEL 6,5056 IN SUMP LEAK TEST REPORT D 12:51 SUMP T -IFILL 6,505 IN T -IFILL END LEVEL 6,5054 IN i V E ERR TEST STARTED 12:51 AM TEST RESULT PASSED i TEST STARTED 06/21/2007 BEGIN LEVEL 6,5052 IN HOLD 0, IN END TIME 1:06 AM r END DATE 08/21/2007 END LEVEL 6,5052 IN LEAK THRESHOLD 0,002 IN TEST RESULT PASSED COSTCO 688 3800 ROSEDALE HWY T -2FILL BAKERSFIELD, CA .CONTAINMENT TED 12:51 1- 800 -984 -6266 ED O6/ 007 V ME ERR 06/21/2007 12:23 AM 12:51 AM 6/21/2007 XLOOOO SUMP LEAK TEST REPORT 0000 IN SHOLD 0, 04 IN T -IFILL LT OR TEST STARTE D 12:08 AM TEST STARTED 06/21/2007 T -2FILL BEGIN LEVEL 6,5056 IN END TIME 12:23 AM D 12:51 END DATE 06/21/2007 D 06/21 7 END LEVEL 6,5054 IN i V E ERR LEAK THRESHOLD 0,002 IN 12:51 AM TEST RESULT PASSED i 6/21/2007 XLEOOO 000 1N HOLD 0, IN T ER i j COSTCO 688 3800 ROSEDALE HWY BAKERSFIELD. CA CONTAINMENT 1 -800- 984 -6266 06/21/2007 1:26 AM SUMP LEAK TEST REPORT T -2FILL TEST STARTED 1:11 AM TEST STARTED 06/21/2007 BEGIN LEVEL 3.2770 IN END TIME 1:26 AM END DATE 06/21/2007 END LEVEL 3.2767 IN LEAK THRESHOLD 0,002 IN TEST RESULT PASSED COSTCO 688 3800 ROSEDALE HWY BAKERSFIELD.CA CONTAINMENT 1 -800- 984 -6266 06/21/2007 1:45 AM SUMP-LEAK TEST REPORT T -2FILL TEST STARTED 1:30 AM TEST STARTED 06/21/2007 BEGIN LEVEL 3.2765 IN END TIME 1:45 AM END DATE 06/21/2007 END LEVEL 3.2762 IN LEAK THRESHOLD 0.002 IN TEST RESULT PASSED COSTCO 688 3800 ROSEDALE HWY 'BAKERSFIELD,CA CONTAINMENT i 1- 800 - 984 -6266 06/21/2007 2:31 AM SUMP LEAK TEST REPORT T -3FILL TEST STARTED 2:16 AM j TEST STARTED 06/21/2007 BEGIN LEVEL 5,0894 IN END TIME 2:31 AM END DATE 05/21/2007 END LEVEL 5,0888 IN LEAK THRESHOLD 0,002 IN TEST RESULT PASSED COSTCO 688 3800 ROSEDALE HWY BAKERSFIELD. CA CONTAINMENT 1- 800 -984 -6266 06/21/2007 2:51 AM SUMP LEAK TEST REPORT T -3FILL TEST STARTED 2:36 AM TEST STARTED 06/21/2007 BEGIN LEVEL 5.0887 IN END TIME 2:51 AM END DATE 06/211/2007 END LEVEL 5.0886 IN LEAK THRESHOLD 0,002 IN TEST RESULT PASSED HORIZONTAL AND VERTICAL DATUM: THE HORIZONTAL AND VERTICAL DATUMS ARE BOTH LOCALIZED DATUMS. BOTH DATUMS ARE BASED ON HORIZONTAL AND VERTICAL INFORMATION DERIVED FROM CONSTRUCTION DRAWINGS FOR COSTCO GAS STATION EXPANSION PROJECT. THE CONTRACTOR SHALL HAVE ANY ADJACENT PROPERTY LINES LOCATED, STAKED AND THE SPATIAL RELATIONSHIP WITH EXISTING AND PROPOSED IMPROVEMENTS VERIFIED BY A PROFESSIONAL LAND SURVEYOR. IN ADDITION THE CONTRACTOR SHALL HAVE THE EXISTING SPOT ELEVATIONS SHOWN ON THE DRAWINGS VERIFIED BY A PROFESSIONAL LAND SURVEYOR PRIOR TO THE START OF CONSTRUCTION. BARGHAUSEN CONSULTING ENGINEERS SHALL IMMEDIATELY BE NOTIFIED OF ANY DISCREPANCIES PRIOR TO THE START OF CONSTRUCTION. INDEX: LANDSCAPE SHEET LANDSCAPE Li k BOUNDARY LINE 1 I GROUNDWATER NOTE: PER THE GEOTECHNICAL REPORT DATED AUGUST 20, 2001 PREPARED BY KLEINFELDER, INC., GROUNDWATER WAS ENCOUNTERED IN THE VICINITY OF THE TANKS AT A DEPTH OF 26 -FEET BELOW GROUND SURFACE AT THE TIME OF THE INVESTIGATION. BOUNDARY LINE n LEGEND EXISTING ASPHALT EXISTING CONCRETE OEM EXISTING ASPHALT TO BE DEMOLISHED - CENTERLINE RIGHT -OF -WAY (EXISTING CONCRETE CURB --- ----------- ----------- - - - - --- (EXISTING EDGE OF PAVEMENT COSTCO WHOLESALE 999 LAKE DRIVE ISSAQUAH, WA 98027 PHONE: (425) 313 -6010 CONTACT: TIM HURLOCKER ENGINEER/APPLICANT BARGHAUSEN CONSULTING ENGINEERS, INC. 18215 72ND AVENUE SOUTH KENT, WA 98032 PHONE: (425) 251 -6222 FAX: (425) 251 -8782 CONTACT: CHRIS TEBALDI Know what's below. Call before you dig. Dial 811 Or Call 800 - 227.2600 PROPOSED ASPHALT PROPOSED CONCRETE PROPOSED BARRIER CURB SAWCUT LINE FLOW PATH PROPOSED SPOT GRADE M.E. MATCH EXISTING FS FINISH SURFACE 0% PROPOSED GRADING SLOPE POWER LINE WORK TO BE DONE THE IMPROVEMENTS CONSIST OF THE FOLLOWING WORK TO BE DONE ACCORDING TO THESE PLANS AND THE SPECIFICATIONS AND STANDARD DRAWINGS OF THE CITY OF BAKERSFIELD INSTALLATION OF AN ABOVE GROUND STORAGE TANK FOR GASOLINE ADDITIVE. GENERAL SITE DEVELOPMENT NOT 1. THE CONTRACTOR SHALL OBTAIN AND HAVE AVAILABLE COPIES OF THE APPLICABLE GOVERNING AGENCY STANDARDS AT THE JOB SITE DURING THE RELATED CONSTRUCTION OPERATIONS. 2. CONTRACTOR SHALL ASSURE THAT ALL NECESSARY PERMITS HAVE BEEN OBTAINED PRIOR TO COMMENCING WORK. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION AND DEPTH OF ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION WHETHER SHOWN ON THESE PLANS OR NOT. UTILITIES OTHER THAN THOSE SHOWN MAY EXIST ON THIS SITE. ONLY THOSE UTILITIES WITH EVIDENCE OF THEIR INSTALLATION VISIBLE AT GROUND SURFACE OR SHOWN ON RECORD DRAWING PROVIDED BY OTHERS ARE SHOWN HEREON. EXISTING UNDERGROUND UTILITY LOCATIONS SHOWN ARE APPROXIMATE ONLY AND ARE SUBJECT TO A DEGREE OF UNKNOWN VARIATION. SOME UNDERGROUND LOCATIONS SHOWN HEREON MAY HAVE BEEN TAKEN FROM PUBLIC RECORDS. BARGHAUSEN CONSULTING ENGINEERS, INC. ASSUMES NO LIABILITY FOR THE ACCURACY OF PUBLIC RECORDS OR RECORDS OF OTHERS. IF CONFLICTS SHOULD OCCUR, THE CONTRACTOR SHALL CONSULT BARGHAUSEN CONSULTING ENGINEERS, INC., TO RESOLVE ALL PROBLEMS PRIOR TO PROCEEDING WITH CONSTRUCTION. 4. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO REVIEW ALL OF THE DRAWINGS AND SPECIFICATIONS ASSOCIATED WITH THE PROJECT WORK SCOPE PRIOR TO THE INITIATION OF CONSTRUCTION. SHOULD THE CONTRACTOR FIND A CONFLICT WITH THE DOCUMENTS RELATIVE TO THE SPECIFICATIONS OR THE RELATIVE CODES, IT IS THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE PROJECT ENGINEER OF RECORD IN WRITING PRIOR TO THE START OF CONSTRUCTION. FAILURE BY THE CONTRACTOR TO NOTIFY THE PROJECT ENGINEER SHALL CONSTITUTE ACCEPTANCE OF FULL RESPONSIBILITY BY THE CONTRACTOR TO COMPLETE THE SCOPE OF WORK AS DEFINED BY THE DRAWINGS AND IN FULL COMPLIANCE WITH LOCAL REGULATIONS AND C-iDES. 5. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE APPROPRIATE UTILITIES INVOLVED PRIOR TO CONSTRUCTION. 6. INSPECTION OF SITE WORK WILL BE ACCOMPLISHED BY A REPRES'ISHI fE OF THE CITY OF COEUR D'ALENE. INSPECTION OF PRIVATE FACILITIES WILL BE ACCOct i1._, `), BY A REPRESENTATIVE OF THE OWNER. IT SHALL BE THE CONTRACTOR'S RESPNSIBILITY TO NOTIFY THE INSPECTOR 24 HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION. 7. PRIOR TO ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY THE CONTRACTOR SHALL CONTACT THE AGENCY AND /OR UTILITY INSPECTION PERSONNEL AND ARRANGE ANY REQUIRED PRE- CONSTRUCTION MEETING(S). CONTRACTOR SHALL PROVIDE 72 HRS MIN. ADVANCE NOTIFICATION TO OWNER, FIELD ENGINEER AND ENGINEER OF PRE - CONSTRUCTION MEETINGS. 8. THE CONTRACTOR IS RESPONSIBLE FOR WORKER AND SITE SAFETY AND SHALL COMPLY WITH THE LATEST OSHA STANDARDS AND REGULATIONS, OR ANY OTHER AGENCY HAVING JURISDICTION FOR EXCAVATION AND TRENCHING PROCEDURES. THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING THE "MEANS AND METHODS" REQUIRED TO MEET THE INTENT AND PERFORMANCE CRITERIA OF OSHA, AS WELL AS ANY OTHER ENTITY THAT HAS JURISDICTION FOR EXCAVATION AND /OR TRENCHING PROCEDURES. 9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE SAFEGUARDS, SAFETY DEVICES, PROTECTIVE EQUIPMENT, FLAGGERS, AND ANY OTHER NEEDED ACTIONS TO PROTECT THE LIFE, HEALTH, AND SAFETY OF THE PUBLIC, AND TO PROTECT PROPERTY IN CONNECTION WITH THE PERFORMANCE OF WORK COVERED BY THE CONTRACTOR. ANY WORK WITHIN THE TRAVELED RIGHT -OF -WAY THAT MAY INTERRUPT NORMAL TRAFFIC FLOW SHALL REQUIRE AT LEAST ONE FLAGGER FOR EACH LANE OF TRAFFIC AFFECTED. 10. PROTECTIVE MEASURES SHALL BE TAKEN BY THE CONTRACTOR TO PROTECT ALL ADJACENT PUBLIC AND PRIVATE PROPERTIES AT ALL TIMES DURING CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTION OF ALL EXISTING UTILITY SERVICES THAT ARE TO REMAIN OPERATIONAL WITHIN THE CONSTRUCTION AREA WHETHER SHOWN OR NOT SHOWN ON THE PLANS. 11. TWO (2) COPIES OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. ONE (1) SET WITH RECORDS OF AS -BUILT INFORMATION SHALL BE SUBMITTED TO BARGHAUSEN CONSULTING ENGINEERS, INC. AT COMPLETION OF PROJECT. NOTE: BARGHAUSEN CONSULTING ENGINEERS, INC. DOES NOT WARRANT THAT THE TOPOGf SHOWN ON THESE DRAWINGS IS REPRESENTATIVE OF WHAT IS CONSTRUCTED. IT I TH CONTRACTOR'S RESPONSIBILITY TO COORDINATE WITH THE OWNER TO HAVE ALL iRE"'2m IMPROVEMENTS FIELD VERIFIED PRIOR TO CONSTRUCTION. DISCREPANCIES SHALL B� BROUGHT TO THE ATTENTION OF BARGHAUSEN CONSULTING ENGINEERS, INC. PRIOR TO WORK. UTILITIES AND UTILITY EASEMENTS FOR THIS SITE HAVE NOT BEEN RESEARCHED OR CONFIRMED. VILE CONFLICT NOM THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION, AND DEPTH OF ALL EXISTING UTIILITIES WHETHER SHOWN ON THESE PLANS OR NOT BY POTHOLING THE UTILITIES AND SURVEYING THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. THIS SHALL INCLUDE CALLING UTILITY LOCATE 0 1- 800 - 227 -2600 AND THEN POTHOLING ALL OF THE EXISTING UTILITIES AT LOCATIONS OF NEW UTILITY CROSSINGS TO PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST. LOCATIONS OF SAID UTILITIES AS SHOWN ON THESE PLANS ARE BASED UPON THE UNVERIFIED PUBLIC INFORMATION AND ARE SUBJECT TO VARIATION. IF CONFLICTS SHOULD OCCUR, THE CONTRACTOR SHALL CONSULT BARGHAUSEN CONSULTING ENGINEERS, INC. TO RESOLVE ALL PROBLEMS PRIOR TO PROCEEDING WITH CONSTRUCTION. .s 0; r • i ' ... . 0 .a 6z • 0 0Q 0 �' •' .: 0 . " z LL 0 +. CC C, W 0 VILE CONFLICT NOM THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION, AND DEPTH OF ALL EXISTING UTIILITIES WHETHER SHOWN ON THESE PLANS OR NOT BY POTHOLING THE UTILITIES AND SURVEYING THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. THIS SHALL INCLUDE CALLING UTILITY LOCATE 0 1- 800 - 227 -2600 AND THEN POTHOLING ALL OF THE EXISTING UTILITIES AT LOCATIONS OF NEW UTILITY CROSSINGS TO PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST. LOCATIONS OF SAID UTILITIES AS SHOWN ON THESE PLANS ARE BASED UPON THE UNVERIFIED PUBLIC INFORMATION AND ARE SUBJECT TO VARIATION. IF CONFLICTS SHOULD OCCUR, THE CONTRACTOR SHALL CONSULT BARGHAUSEN CONSULTING ENGINEERS, INC. TO RESOLVE ALL PROBLEMS PRIOR TO PROCEEDING WITH CONSTRUCTION. �o QR�FESSIp�9�F' HAL P. GRUBB -� 6A1 .s 0; r • i �o QR�FESSIp�9�F' HAL P. GRUBB -� 6A1 mMomm"IMENEXXON EX. ASPHALT PAVEMENT FENCE (6' HIGH CHAIN LINK) STORAGE /STAGING AREA C DEMO LANDSCAPING AND IRRIGATION INSIDE PAD LIMITS - DATA DATA DATA - DATA DATA DATA CLEARING LIMITS - ONLY AS NEEDED FOR NEW - CONSTRUCTION GATE EX CURB DEMOLITION FOR \� NEW CURB IMPROVEMENTS DATA DAT DATA DA A PERIMETER PROTECTION CLEARING LIMITS -ONLY AS NEEDED FOR CONDUIT TRENCH , , ROLLS, GRAVEL BAG BERM, SAND BAG BERM OR OTHER APPROVED PERIMETER CATCH BASIN LOCATIONS OF PROTECT SITE ADJACENT TO IMPERVIOUS AREAS AS REQUIRED TO SILT PROTECTIO , (TYP) , , O CONSTRUCTION STAGING AREA (APPROXIMATE , , , , AS NECESSARY DURING CONSTRUCTION). , CONTRACTOR TO UTILIZE THIS AREA FOR: EX. ASPHALT PAVEMENT , , , , P� O �P A DATA DATA DATA DATA DATA DATA DATA DATA DATA D>ATAEX. DATA DATA _OP )ATA DATA DATA DATA DATA DATA DATA DATA DAT DATA DATA EX. DATADATA BEGIN DEMOLITION PERIMETER FOR NEW CURB EX. CONCRETE PAD TO BE PERIMETER 1 CLEARING LIMITS PROTECTION`-: IMPROVEMENTS DEMOLISHED AND REMOVED PROTECTION _ ONL7 WITHIN SAW -CUT LIMITS O FOR CONDUIT TRENCH EX. LS AREA --\ DEMOLITION CALLOUTS O PROVIDE AND INSTALL CATCH BASIN SILT PROTECTION PER DETAIL 1, THIS SHEET. ® TEMPORARY CONSTRUCTION FENCE (6' HIGH CHAIN LINK). FIELD VERIFY AND CONFIRM EXACT LOCATION WITH ARCHITECT /STORE MANAGER. ODEMOLISH /REMOVE EXISTING LANDSCAPING /IRRIGATION INCLUDING TREES, SHRUBS, GROUND COVER, ROOTS, ETC. AS REQUIRED FOR TANK IMPROVEMENTS. OCONTRACTOR TO INSTALL SILT FENCE, FIBER ROLLS, GRAVEL BAG BERM, SAND BAG BERM OR OTHER APPROVED PERIMETER PROTECTION AT ALL PERIMETER LOCATIONS OF PROTECT SITE ADJACENT TO IMPERVIOUS AREAS AS REQUIRED TO PREVENT SILT -LADEN RUNOFF FROM LEAVING SITE, AND AS DIRECTED BY CITY INSPECTOR. •: O CONSTRUCTION STAGING AREA (APPROXIMATE LOCATION, CONTRACTOR TO ADJUST AS NECESSARY DURING CONSTRUCTION). CONTRACTOR TO UTILIZE THIS AREA FOR: VEHICLE AND EQUIPMENT CLEANING THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION. DIMENSION AND DEPTH OF ALL EXISTING UTILITIES WHETHER SHOWN ON THESE PLANS OR NOT BY POTHOLING THE VEHICLE AND EQUIPMENT FUELING •' EQUIPMENT AND VEHICLE WASHDOWN AREA APPROXIMATE, BASED ON FIELD SURVEYS AND AS -BUILT RECORDS. "POTHOLE" MATERIAL DELIVERY AND STORAGE 0? CONCRETE WASTE MANAGEMENT EROSION CONTROL NOTES: 1. ALL NECESSARY EQUIPMENT AND MATERIALS SHALL BE AVAILABLE ON SITE TO FACILITATE RAPID INSTALLATION OR EROSION AND SEDIMENT CONTROL BMPS WHEN LEGEND RAIN IS EMINENT. 2. THE CONTRACTOR SHALL RESTORE ALL EROSION CONTROL DEVICES TO WORKING CATCH BASIN ORDER TO THE SATISFACTION OF THE CITY ENGINEER AFTER EACH RUN -OFF SILT PROTECTION PRODUCING RAINFALL. EXISTING CURB 3. THE CONTRACTOR SHALL INSTALL ADDITIONAL EROSION CONTROL MEASURES AS MAY BE REQUIRED BY THE CITY ENGINEERING OR BUILDING INSPECTOR DUE TO UNCOMPLETED GRADING OPERATIONS OR UNFORESEEN CIRCUMSTANCES WHICH MAY CLEARING LIMITS ARISE. 4. ADEQUATE EROSION AND SEDIMENT CONTROL AND PERIMETER PROTECTION BEST CONSTRUCTION FENCE MANAGEMENT PRACTICE MEASURES MUST BE INSTALLED AND MAINTAINED. PERIMETER PROTECTION O STORM O EX. CONTF ENCLOSUR t SD - 1. ATTEND PRECONSTRUCTION MEETING WITH THE CITY OF FAIRFIELD. 2. FLAG CLEARING LIMITS. 3. INSTALL PERIMETER PROTECTION BMPS AS SHOWN ON PLANS. 4. INSTALL STORM DRAIN INLET PROTECTION AS SHOWN ON PLANS. 5. CLEAR AND GRUB SITE, COMPLETE DEMOLITION AND PERFORM ROUGH GRADING. 6. CONSTRUCT SITE IMPROVEMENTS. 7. REMOVE PERIMETER PROTECTION BMPS AND STORM DRAIN INLET PROTECTION. 8. CALL THE CITY OF FAIRFIELD FOR FINAL INSPECTION. D 1L Z, A 0 Ri 41 11•1 1 ;I I 1. SILTATION BARRIERS SHALL BE INSPECTED IMMEDIATELY AFTER EACH RAINFALL AND AT LEAST DAILY DURING PROLONGED RAINFALL. CLOSE ATTENTION SHALL BE PAID TO THE REPAIR OF DAMAGED BALES, END RUNS AND UNDERCUTTING BENEATH BALES. NECESSARY REPAIRS TO BARRIERS OR REPLACEMENT OF BALES SHALL BE ACCOMPLISHED PROMPTLY. SEDIMENT DEPOSITS SHOULD BE REMOVED AFTER EACH RAINFALL. THEY MUST BE REMOVED WHEN THE LEVEL OF DEPOSITION REACHES APPROXIMATELY ONE -HALF THE HEIGHT OF THE BARRIER. ANY SEDIMENT DEPOSITS REMAINING IN PLACE AFTER THE STRAW BALE BARRIER IS NO LONGER REQUIRED SHALL BE DRESSED TO CONFORM TO THE EXISTING GRADE, PREPARED AND SEEDED. ENDS OF FILTER FABRIC FRAME AND GRATE SANDWICHED BETWEEN GRATE AND FRAME - pv�v�v�uOV� FILTERED RUNOFF NOTE: `- CATCH BASIN 1. ALL FILTER FABRIC SHALL BE 15 MIL (MIN.) "ENVIROFENCE #10800- BY NICOLON CORP. OR APPROVED EQUAL. 2. CONTRACTOR SHALL CHECK THE CONDITION OF THE FILTER AT THE BEGINNING AND END OF EACH WORK DAY AND REPAIR /CLEAN AS NECESSARY. TEMPORARY SEDIMENT BARRIER AT DRAIN INLET J NOT TO SCALE DEMOLITION NOTES: 1. ALL PAVEMENTS, SLABS, GROUND COVER, UTILITIES, ETC., INSIDE DEMOLITION LIMITS SHALL BE REMOVED UNLESS OTHERWISE SHOWN ON THE PLANS. 2. CONTRACTOR SHALL CONTACT AND COORDINATE WITH THE VARIOUS UTILITY COMPANIES ON REQUESTING DISCONNECTIONS, REMOVALS AND /OR RELOCATION OF EXISTING SERVICE. 3. CONTRACTOR SHALL ASSURE THAT ALL NECESSARY PERMITS AND CONSTRUCTION APPROVALS HAVE BEEN OBTAINED PRIOR TO COMMENCING WORK. 4. CONTRACTOR SHALL REPLACE ALL EXISTING CURB, PAVEMENT, AND /OR LANDSCAPING DAMAGED AS A RESULT OF CONSTRUCTION ACTIVITY. 5. CONTRACTOR SHALL, PRIOR TO CONSTRUCTION OR REMOVAL OF IMPROVEMENTS, FIELD VERIFY AND CONFIRM LIMITS OF DEMOLITION AS WELL AS EXISTING UTILITIES AND IMPROVEMENTS TO REMAIN. HAULING SILTATION CONTROL NOTES: 1. PUBLIC STREETS ARE TO BE KEPT CLEAN OF DIRT AND DEBRIS GENERATED BY WORK. CLEANUP SHALL BE BY SWEEPING AND /OR OTHER APPROVED METHODS ON A DAILY BASIS. 2. CONTRACTOR SHALL PROVIDE SILT BAGS OR OTHER SILTATION CONTROL MEASURES THAT MAY BE REQUIRED BY THE CITY DURING THE COURSE OF THE WORK. 3. EFFORTS SHALL BE MADE DURING CONSTRUCTION ACTIVITIES TO STABILIZE ALL DISTURBED AREAS AS QUICKLY AS POSSIBLE TO MINIMIZE EROSION. 4. CONTRACTOR SHALL PROVIDE SILT BAGS OR OTHER APPROVED SILTATION CONTROL DEVICE ON EXIST. CATCH BASIN(S) IN PROXIMITY OF WORK WHICH HAVE POTENTIAL TO RECEIVE SURFACE RUNOFF FROM WORK AREA. 6. ITEMS FOR DEMOLITION ARE DEPICTED PER DESIGN DRAWINGS. CONTRACTOR TO VERIFY AND LOCATE ANY ITEMS FOR DEMOLITION PRIOR TO START OF CONSTRUCTION AND NOTIFY BARGHAUSEN CONSULTING ENGINEERS, INC. IMMEDIATELY OF ANY DISCREPANCIES. 7. CONTRACTOR TO REVIEW AS -BUILT DRAWINGS IN PROJECT AREA AND REMOVE AND OR RELOCATE ANY SITE APPURTENANCES IN PROJECT AREA THAT IMPACTS THE PROJECT. GENERAL NOTES: 1. CONTRACTOR TO HAVE BOUNDARY LINE ADJACENT TO TANK VERIFIED AND FIELD STAKED BY A PROFESSIONAL LAND SURVEYOR PRIOR TO CONSTRUCTION. 2. REMOVE EXISTING LANDSCAPING AND RE -ROUTE EXISTING IRRIGATION SYSTEM AROUND TANK PAD IMPROVEMENTS AS NECESSARY TO MAINTAIN IRRIGATION TO THE SITE. 3. ONE OR MORE PORTABLE FIRE EXTINGUISHERS HAVING A RATING OF NOT LESS THAN 40BC SHALL BE LOCATED NEITHER LESS THAN 10 FEET NOR MORE THAN 50 FEET FROM THE TANK STORAGE AREA. 4. CONTRACTOR ASSUMES RESPONSIBILITY TO ASSURE THAT THE OPERABLE SYSTEM MEETS THE DESIGN INTENT. THE CONTRACTOR IS PERMITTED TO ADJUST SIZES AND CUTS BASED ON ACTUAL FIELD CONDITIONS AND INSTALLATION TECHNIQUES. F it UTILRY GONFlJCT NOTES FIELD VERIFY ALL EXISTING AND NEW UTILITIES PRIOR TO CAS •: i CONSTRUCTION. SEE UTILITY CONFLICT NOTE THE EXISTING WATER, STORM, AND SANITARY SEWER SERVICE SHOWN IS THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION. DIMENSION AND DEPTH OF ALL EXISTING UTILITIES WHETHER SHOWN ON THESE PLANS OR NOT BY POTHOLING THE •' o a APPROXIMATE, BASED ON FIELD SURVEYS AND AS -BUILT RECORDS. "POTHOLE" UTILITIES AND SURVEYING THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. 0? • • THIS SHALL INCLUDE CALLING UTILITY LOCATE 0 1 -800- 227 -2600 AND THEN POTHOLING •` °(D TO VERIFY THE DIAMETER AND LOCATION (INCL. ELEVATIONS) PRIOR TO ALL OF THE EXISTING UTILITIES AT LOCATIONS OF NEW UTILITY CROSSINGS TO PHYSICALLY E �o Q�pFES510Nq� HAL P. RUBS ?, 81 CAUTION! POTENTIAL UTILITY CONFLICT. CONTRACTOR SHALL UTILRY GONFlJCT NOTES FIELD VERIFY ALL EXISTING AND NEW UTILITIES PRIOR TO CAS i CONSTRUCTION. SEE UTILITY CONFLICT NOTE THE EXISTING WATER, STORM, AND SANITARY SEWER SERVICE SHOWN IS THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION. DIMENSION AND DEPTH OF ALL EXISTING UTILITIES WHETHER SHOWN ON THESE PLANS OR NOT BY POTHOLING THE o a APPROXIMATE, BASED ON FIELD SURVEYS AND AS -BUILT RECORDS. "POTHOLE" UTILITIES AND SURVEYING THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. THE GENERAL CONTRACTOR SHALL THE EXISTING UTILITIES THIS SHALL INCLUDE CALLING UTILITY LOCATE 0 1 -800- 227 -2600 AND THEN POTHOLING .n °(D TO VERIFY THE DIAMETER AND LOCATION (INCL. ELEVATIONS) PRIOR TO ALL OF THE EXISTING UTILITIES AT LOCATIONS OF NEW UTILITY CROSSINGS TO PHYSICALLY E CONSTRUCTION. ANY DISCREPANCIES IN THE LOCATION OF THE VERIFY WHETHER OR NOT CONFLICTS EXIST. LOCATIONS OF SAID UTILITIES AS SHOWN ON THESE z 00 o °o EXISTING PIPE OR INCOMPATIBILITY OF THE DESIGN SHALL BE PLANS ARE BASED UPON THE UNVERIFIED PUBLIC INFORMATION AND ARE SUBJECT TO VARIATION. a BROUGHT TO THE IMMEDIATE ATTENTION OF THE OWNERS REPRESENTATIVE, IF CONFLICTS SHOULD OCCUR, THE CONTRACTOR SHALL CONSULT BARGHAUSEN -' a_ AND BARGHAUSEN CONSULTING ENGINEERS (425- 251 - 6222). CONSULTING ENGINEERS, INC. TO RESOLVE ALL PROBLEMS PRIOR TO PROCEEDING WITH CONSTRUCTION. LE ® ids STOP ADDITIVE TANK INSTALLATION I I / INSTALL ONE (1) 1,200 GALLON "CONTAINMENT SOLUTIONS" UL -2085 "PROTECTED" DOUBLE WALL ABOVEGROUND STEEL TANK WITH ANNULAR SPACE MONITORED BY "VEEDER ROOT" TLS -350R TANK AND PIPING MONITORING AND ALARM SYSTEM. TANK TO I / BE SET AND ANCHORED AT GRADE. SEE DWG. T1 FOR ADDITIONAL INFORMATION. TANK INSTALLATION SHALL BE IN ACCORDANCE i I EX. LS AREA EX, E.S.O. SWITCH // I WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS. H, r LOCATION OF FACTORY- INSTALLED 6" EMERGENCY VENTS FOR PRIMARY AND SECONDARY TANK. / O LOCATION OF FACTORY- INSTALLED 2" ADDITIVE FILL ADAPTER AND CAP INSIDE NEW SPILL BOX, LOCATED AT NEW TANK. PAVEMENT ASPHALT 4 TERMINATION POINT OF TANK VENT TO BE A MINIMUM OF 12' ABOVE GRADE AND NOT WITHIN 5' FROM ANY BUILDING OPENING OR PROPERTY LINE THAT CAN BE BUILT UPON. VENT RISERS SHALL BE INSTALLED IN ACCORDANCE WITH j I - - - - - - - - - - - - - - - - - INTERNATIONAL FIRE CODE REQUIREMENTS. INSTALL ONE. (1) DRY TANK ANNULAR SPACE MONITORING SENSOR AND TIE INTO EXISTING VEEDER -ROOT TLS -350 PANEL IN CONTROLLER ENCLOSURE, / EX. ASPHALT UPDATE EXISTING "VEEDER ROOT" TANK AND LINE ALARM CONTROL PANEL MODEL # TLS -35OR IN EQUIPMENT PAVEMENT ENCLOSURE BUILDING, DUE TO ADDITIONAL ADDITIVE SYSTEM MONITORING SENSOR REQUIREMENTS. SEE ELECTRICAL => DRAWINGS FOR SCOPE. I----- m---- - - - - -� , I I � NEW ABOVEGROUND TANK TO BE GROUNDED TO NEW GROUND ROD. CONTRACTOR TO PROVIDE NEW 1/2 "x10' GROUND ROD AS EX STORM 7 REQUIRED. SEE SHEET T1. I I I EX. CURB " - - - - - - - i0 - - - - - - - � L=-� NKASHALL EIN LY PLACARDS D TAGGED WITH STANDARD API IDENTIFICATION MARKINGS AT NEW TANK FILL. INSTALL NFPA f => o Q CONTRACTOR TO INSTALL ONE (1) FE PETRO 3/4 HP TURBINE ON TANK AS SHOWN. SEE SHEET T1 FOR INSTALLATION DETAILS. CONTRACTOR TO PURGE LINES THROUGH EACH NEW SOLENOID VALVE PER COSTCO'S "PURGING AND CALIBRATING" INSTRUCTIONS. ANY AIR POCKETS OR START UP PROBLEMS DUE TO IMPROPER INSTALLATION OR INCORRECT WIRING THAT DESTROYS ELECTRONICS WILL BE BILLED BACK TO THE CONTRACTOR of 1 p TANK TO BE EQUIPPED WITH FACTORY - INSTALLED KRUEGER LEVEL GAUGE. ~I ®- a ®- G F E D 7 11 INSTALL ONE (1) 3" OVER 2" DOUBLE WALL FIBERGLASS (AMERON) ADDITIVE SUPPLY LINE HEADER TO ALL GASOLINE "'I EX. TANK C 7 TANKS. PIPING SHALL BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS AND INSTRUCTIONS. CONTRACTOR TO wl TURBINES EX. DISPE ER ARE INSTALL TRACER 'WIRE WITH PRODUCT PIPING. TESTING OF PRODUCT LINE SHALL BE PERFORMED PRIOR TO BACKFILL, - - - - - - - - PRIOR TO PAVING AND BEFORE STATION OPERATION, BRAVO PIPING AND ELECTRICAL PENETRATIONS ON TANK SUMPS EX. ASPHALT =J = TO BE INSTALLED PER THE MANUFACTURES RECOMMENDATION AND TESTING PROCEDURES. FIBERGLASS WRAP THE PAVEMENT I - -- -- -- -- -- - --- - ---T -- - OUTSIDE OF ALL INEW PENETRATION FITTINGS WITH FOUR LAYERS OF FIBERGLASS. ALL BRAVO PENETRATIONS, GLUE EX. CURB EX. CONCRETE PAD / AND FIBER GLASSING KITS TO BE SUPPLIED BY COSTCO, I CLASS I, C 7 12 FOR EXISTING GASOLINE DISPENSING SYSTEM, INSTALL ONE DEDICATED RECEPTACLE TIED TO ESO SYSTEM AND DIVISION 2 / 12 INSTALL NEW SURGE INSTALL NEW DATA DISCONNECT AND SURGE SUPPRESSION DEVICE IN CONTROLLER ENCLOSURE I AT TRANSITION SUMP EX. CURB S PPRESSION AND 13 INSTALL NEW "FLOW DYNAMICS" ADDITIVE BATCH CONTROLLER INSIDE OF EXISTING CONTROLLER ENCLOSURE. INSTALL ( D SPENSER DATA f 9 NEW FLOW METER AT NEW ADDITIVE TANK TURBINE SUMP, AND INSTALL NEW 24VOLT SOLENOID VALVES AT EACH DSCONNECT SYSTEM EXISTING FILL SUMPS. SEE SHEET T -2 & T -3 FOR SUMP DETAILS. SEE SHEETS E -1 THROUGH E -4 FOR ELECTRICAL X WIRING AND DETAILS, J I 6 EXISTING VEEDER 14 ALL NEW PIPING AND TANK TO BE INSTALLED PER MANUFACTURERS RECOMMENDATIONS AND INSTALLATION — -�-� ROOT TLS 350R INSTRUCTIONS. CONTRACTOR SHALL USE FLEXIBLE CONNECTORS FROM THE TANK SUMPS TO THE VENT AND PRODUCT CONDUITS PANEL TANK CONNECTION. THERE SHALL BE A MINIMUM FOR 4 FEET OF PIPING RUN PRIOR TO PENETRATION INTO ANY SUMP �i -_; ___ CHANGE OF DIRECTION OF MORE THAN 30 DEGREES PER MANUFACTURERS INSTALLATION REQUIREMENTS. DATA 4ATA EX DATA 61NF�AS DATA DATA DATA DATA D A E�PJA LINES D TA DATA �O 15 THE OWNERS REAL ESTATE DEPARTMENT WILL IDENTIFY THE FIRE AGENCY HAVING JURISDICTION, ALL INITIAL DELIVERY DATA DATA DATA DATA DATA ATA DATA D TA DATA D TA DATA REQUIREMENTS AND FORMS AND SEND TO CONSULTING CONSTRUCTION MANAGER (JONES COVEY) FOR DISTRIBUTION AND SIGNATURES. CONSULTING ENGINEER BARGHAUSEN CONSULTING SHALL SECURE THE OWNER'S AND INSTALLER'S TANK FILL CLASS 1 EX. E.S.O. S ITCH EX. GAS STATION ) DIVISION 2 A O TRANSFORMER SIGNATURES AND DISTRIBUTE FORMS TO THE REAL ESTATE DEPARTMENT, THE OWNER'S ADDITIVE BUYING DEPARTMENT, EX. HEALY CLEAN 7 B TANK THE GENERAL CONTRACTOR AND THE AGENCY'S HAVING JURISDICTION. REQUIRED FORMS TYPICALLY INCLUDE, BUT ARE 7 A EX. CONTROLLER NOT LIMITED TO UST REGISTRATION AND LICENSING, MONITORING CERTIFICATION, ALL AHJ INITIAL DELIVERY REQUIREMENTS FILLS AIR SEPARATOR UNIT X. VENT STACK EX. LS AREA ENCLOSURE SHALL BE SATISFIED AND WRITTEN DOCUMENTATION SENT TO THE OWNER'S ADDITIVE BUYING GROUP /DEPT, PRIOR TO ON CONCRETE PAD. ORDERING ADDITIVE. ADDITIVE DELIVERY AND ALL TANK TESTING SHALL BE COMPLETE PRIOR TO OPERATION. INSTALL NEW BRAVO SINGLE WALL FIBERGLASS PIPING TRANSITION SUMP WITH VEEDER -ROOT SENSOR AT BASE OF NEW ABOVEGROUND ADDITIVE TANK, PREPARATION AND INSTALLATION OF NEW BRAVO TRANSITION SUMP AND PIPING PENETRATION FITTING TO BE PER THE MANUFACTURES RECOMMENDATION AND TESTING PROCEDURES, EX. BOUNDARY LINE FIBERGLASS WRAP THE OUTSIDE OF ALL NEW PENETRATION FITTINGS WITH FOUR LAYERS OF FIBERGLASS. ALL EX, BOUNDARY LINE BRAVO PENETRATIONS, GLUE AND FIBER GLASSING KITS TO BE SUPPLIED BY COSTCO. ELECTRICAL NOTES: ESEE MATERIALS LIST (T2) FOR SPECIFICATIONS ON EQUIPMENT USED IN THIS CONSTRUCTION. 2 CONDUIT ROUTING SHOWN ARE SCHEMATIC. CONTRACTOR TO FIELD DETERMINE BEST SITE PLAN CONDUIT ROUTING AND PROVIDE FINAL LOCATIONS SHOWN ON AS -BUILT DRAWINGS. ElALL EQUIPMENT SHALL BE INSTALLED AS PER MANUFACTURER'S SPECIFICATIONS. FUNCTIONS OF THE ADDITIVE TANK MONITORING: EX. ASPHALT - MONITORING OF TANK ANNULAR SPACE. PAVEMENT ` - PROVIDE CONTINUOUS TANK LEVEL MONITORING. RE mm mm mm mmum ROOM � omm XEM As mm mm mm mm man mma mm amm mom M40 - MONITORING OF ADDITIVE TRANSITION SUMP P G TO COMPLIANCE NOTES: 1. CIVIL DRAWINGS SHALL TAKE PRECEDENCE FOR REFERENCING ALL DIMENSIONS, PROPERTY LINES, ELEVATIONS AND EQUIPMENT LOCATIONS, 2. ALL DIMENSIONS AND CONDITIONS SHALL BE CHECKED AND VERIFIED IN THE FIELD BEFORE STARTING ANY WORK. ANY DISCREPANCY SHALL BE CALLED TO THE ATTENTION OF THE OWNERS ENGINEER FOR HIS DECISION BEFORE PROCEEDING WITH THE WORK. 3. GENERAL CONTRACTOR SHALL OBTAIN NECESSARY PERMIT FROM APPLICABLE AGENCIES FOR EXCAVATIONS OF TRENCHES 5' -0" OR MORE IN DEPTH INTO WHICH A PERSON IS REQUIRED TO DESCEND (IF REQUIRED). 4. AN UNAUTHORIZED RELEASE RESPONSE PLAN SHALL BE SUBMITTED AND APPROVED BY GOVERNING AGENCY PRIOR TO TANK OPERATIONS (BY OWNER IF REQUIRED). 5. THE ABOVEGROUND STORAGE TANK SYSTEM SHALL BE COMPATIBLE WITH THE PRODUCT STORED. ALL MATERIALS SHALL BE COMPATIBLE WITH USE FOR THE INTENDED PURPOSE AS PER NATIONALLY RECOGNIZED CODES, LOCAL CODES AND GOVERNING AUTHORITIES. 6. ALL MONITORING DEVICES SHALL BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 7. GENERAL CONTRACTOR IS REQUIRED TO PROVIDE 72 HOUR (TYPICAL) NOTIFICATION TO GOVERNING AGENCY PRIOR TO TANK INSTALLATION. 8. TANK AND PIPING SYSTEM TO BE INSPECTED BY OWNER'S FUEL FACILITY INSTALLATION OVERSIGHT AGENT (JONES COVEY) & GOVERNING AGENCY 9. TANK SYSTEM MONITORING SYSTEM INTEGRITY TESTS FORWARDED AND APPROVED BY GOVERNING AGENCY PRIOR TO ADDITIVE SYSTEM BEING PLACED IN OPERATION, 10. PRIOR TO FIRST ADDITIVE FILL, STATION MUST HAVE VEEDER ROOT FUNCTIONAL AND MONITORING ANNULAR SPACE OF TANK. 11. PAYMENT OF ALL APPLICABLE UST OPERATING FEES SHALL BE SUBMITTED TO THE GOVERNING JURISDICTION WITHIN 30 DAYS OF THE FINAL INSPECTION. 12. EVIDENCE OF FINANCIAL RESPONSIBILITY SHALL BE SUBMITTED TO GOVERNING AGENCY (BY OWNER). 13, NEW TRANSITION SUMP SHALL BE HYDROSTATICALLY TESTED (LAKE TEST) WITH STANDING WATER FOR A PERIOD OF 24 HOURS TO INSURE THAT THE SUMP IS WATERTIGHT. RECORD THE TEST RESULTS AND SUBMIT TO OWNERS CONSTRUCTION PM (JONES COVEY) N.E.C. HAZARDOUS AREA NOTES < ,q� TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (TANK - FILL OPENING) EXTENT OF CLASS 1, GROUP D, DIVISION 1 LOCATION: ANY PIT, BOX, OR SPACE BELOW GRADE LEVEL, ANY PART OF WHICH IS WITHIN THE DIVISION 1 OR 2 CLASSIFIED LOCATION. EXTENT OF CLASS 1, GROUP D, DIVISION 2 LOCATION: UP TO 18 INCHES ABOVE GRADE LEVEL WITHIN A HORIZONTAL RADIUS OF 10 FEET FROM A LOOSE FILL CONNECTION AND WITHIN A HORIZONTAL RADIUS OF 5 FEET FROM A TIGHT FILL CONNECTION, TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (TANK - VENT - DISCHARGING UPWARD) EXTENT OF CLASS 1, GROUP D, DIVISION 1 LOCATION: WITHIN 3 FEET OF OPEN END OF VENT, EXTENDING IN ALL DIRECTIONS. EXTENT OF CLASS 1, GROUP D, DIVISION 2 LOCATION: SPACE BETWEEN 3 FEET AND 5 FEET OF OPEN END OF VENT, EXTENDING IN ALL DIRECTIONS. C TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (REMOTE PUMP - OUTDOOR) EXTENT OF CLASS 1, GROUP D, DIVISION 1 LOCATION: ANY PIT, BOX, OR SPACE BELOW GRADE LEVEL IF ANY PART IS WITHIN A HORIZONTAL DISTANCE OF 10 FT. FROM ANY EDGE OF PUMP. EXTENT OF CLASS 1, GROUP D, DIVISION 2 LOCATION: WITHIN 3 FEET OF ANY EDGE OF PUMP, EXTENDING IN ALL DIRECTIONS. ALSO UP TO 18 INCHES ABOVE GRADE LEVEL WITHIN 10 FEET HORIZONTALLY FROM ANY EDGE OF PUMP. TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (DISPENSING DEVICE - PITS) D EXTENT OF CLASS 1, GROUP D, DIVISION 1 LOCATION: ANY PIT, BOX, OR SPACE BELOW GRADE LEVEL, ANY PART OF WHICH IS WITHIN THE DIVISION 1 OR 2 CLASSIFIED LOCATION. 0IE TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (DISPENSING DEVICE - DISPENSER) EXTENT OF CLASS 1, GROUP D, DIVISION 1 LOCATION: SPACE CLASSIFICATION INSIDE THE DISPENSER ENCLOSURE IS COVERED IN ANSI /UL 87, "POWER OPERATED DISPENSING DEVICES FOR PETROLEUM PRODUCTS." TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (DISPENSING DEVICE - DISPENSER) IF EXTENT OF CLASS 1, GROUP D, DIVISION 2 LOCATION: WITHIN 18 INCHES HORIZONTALLY IN ALL DIRECTIONS EXTENDING TO GRADE FROM (1) THE DISPENSER ENCLOSURE OR (2) THAT PORTION OF THE DISPENSER ENCLOSURE CONTAINING LIQUID HANDLING COMPONENTS. TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (DISPENSING DEVICE - OUTDOOR) G EXTENT OF CLASS 1, GROUP D, DIVISION 2 LOCATION: UP TO 18 INCHES ABOVE GRADE LEVEL WITHIN 20 FEET HORIZONTALLY OF ANY EDGE OF ENCLOSURE. I EX. ASPHALT - MONITORING OF PII IN A1,45I1I0N SUMP PLAN PAVEMENT - _ THE CONTINUOUS MONITORING DEVICE SHALL PROVIDE AUDIBLE /VISUAL ALARM AUTOMATICALLY IN THE NSTUCTIN NOTES j ------------ -- - - -- -- - °-- - ----- --- -�- ------------------------------------- " -' AS INDICATED ON SITE PLAN. ITCH 1 FLUSH CURB PER DETAIL 8, SHEET C4. EVENT OF A LIQUID RELEASE AND A COMPLETE SHUTDOWN MANUALLY LOCATED ON THE KIOSK ENCLOSURE AND REMOTE ESO SWITCH O I ALL WIRES ENTERING CONTROL PANELS, MAIN PANELS, AND SUB PANELS SHALL BE I MARKED WITH PHASE TAPE CODING AS FOLLOWS: I " " O CONCRETE PAD PER DETAIL 5, SHEET C4. ONCRETE - "B" PHASE = REDCK. ' "C" PHASE = BLUE . I O CAST -IN -PLACE CONCRETE CURB PER DETAIL 6„ SHEET C4. I o ALL CONDUCTORS SHALL BE CONTINUOUS (WITH NO SPLICES) STRANDED 7 B X. R U .D''. COPPER WITH 75'C THWN INSULATION, OIL AND GAS RESISTANT. EX. VENT STACK TO G Ys. TANK SLAB PER DETAIL 1, SHEET C4. PIPE TRANSITION 16 - -- -�- - A SEAL OFF MUST BE INSTALLED PRIOR TO ENTERING AND LEAVING A CLASSIFIED AREA. wom mom SUMP CONDUITS FIRST EMERGENCE FROM BELOW GRADE MUST BE CONNECTED TO A SEAL -OFF. CLEAN EDGE FOR MATCHING I 2" DW PR DUC NEW SOLENOI SAWCUT LINE. CONTRACTOR TO PROVIDE A SMOOTH PRIMARY TANK 4 1 14 11 ..SUPPLY LI. E 13 VALVES IN FILL ALL CONDUITS SHALL HAVE INSULATED GROUNDING BUSHINGS INSTALLED AND TIED O INTO EXISTING PAVEMENT. REMOVE CURB ALONG FRONT OF TANK PAD AND VENT 1.0% MIN. SUMP D TOGETHER W/ #6 BARE COPPER WIRE. BOND ALL INSULATED GROUNDING BUSHINGS AND SAW -CUT ONLY WHAT IS NECESSARY FOR PROVIDING A CLEAN EDGE. isy - GUTTER BOX BACK 'TO POWER CENTER GROUND. POWER, DATA AND MONITORING CONDUITS. ROUTE NEW CONDUITS TO EXISTING _J 4' 2 CONCRETE PAD 8 9 ALL INSTALLATIONS :SHALL BE PER N.E.C., ARTICLE 514. O CONTROLLER ENCLOSURE AND PULL NEW WIRE AS REQUIRED. l F� /_- _ _ = -� - _� =� = _ _ °• _ _ _ _ _ _ _ _ ° _ _ _ _ _ _ _ _ _ ° _ _ —�— O7 NEW GUARD POST (5) PER DETAIL 7, SHEET C4. 2 SOLENOID< 6 1 Q ALL EQUIPMENT SHALL BE U.L. APPROVED. �o l GUARD POSTS 7 ® ® POWER ° 1 1 NOT USED O TANK SLAB REPLACEMENT AREA PER DETAIL 9 SHEET C4. TANK SLAB 4 END NEW CURB g IMPROVEMENTS 9 REPLACE EX. CURB IN -KIND AS NECESSARY. LJ ® ® , ... ... MATCH EX. / 12 NOT USED O - t - _ _ _ _ _.------ _ _ ALL ELECTRICAL JUNCTION BOXES SHALL BE EXPLOSION PROOF WITH SEAL -OFF EX. LS AREA + ` - L - - - - - - ! - - - 13 ENTERING AND LEAVING. SEAL -OFFS TO BE A MAXIMUM OF 18" ABOVE GRADE. AT A 8 3 TANK FILL L__ __ _:_ SIOLENOJD __- 3 SOLENOID_* __ _ __ CURB 3 POWER POWER g 8 5 SAWCUT MINIMUM, THE LAST 2' OF ANY CONDUIT RUN ENTERING OR LEAVING A HAZARDOUS 1 FLOW METER 5 TANK ANNULAR AREA SHALL BE RIGID METAL CONDUIT (TYP.) DATA DATg ��feTA DATA DATA DATA DAT DATA DA A DATA DATA DATA DATA rAgTA DATA DATAT�X DATA LINpAT DATA DATA DATA DAT DST DATA DATA DATA DATA DAT�EX D DATAINE� DATA H ALL NONMETALLIC CONDUIT (IF USED) SHALL HAVE THE LAST 2' (AT 6 IUI INEO BEGIN NEW CURB CONTROLLER ENCLOSURE) OR 10' (AT SUMPS) OF THE UNDERGROUND RUN POWER g EX. CONCRETE TO THE POINT OF EMERGENCE OR TO THE POINT OF CONNECTION TO THE IMPROVEMENTS/ ABOVE GROUND RACEWAY TO BE THREADED RIGID METAL CONDUIT. THE ABOVEGROUND "CSI" A C 1 7 5 MONITORING (D MATCH EX. RIGID NONMETALLIC CONDUIT INCLUDING RIGID NONMETALLIC CONDUIT ELBOWS ADDITIVE STORAGE TANK. 9 10 . & FITTINGS ARE REQUIRED TO BE LOCATED NOT LESS THAN 2' BELOW TANK IS 1,200- GALLON T-' T-1 EX. HEALY CLEAN GRADE. TRANSITIONS TO STEEL OCCURS AT THE 90 DEGREE FITTING UP, UL -2085 "PROTECTED" AIR SEPARATOR UNIT INCLUDING THE ELBOW. ALL METAL CONDUIT & FITTINGS SHALL BE ROBROY, DOUBLE WALL STEEL W/ 6 D ON CONCRETE PAD. NO EXCEPTIONS. WRAPPED RIGID METALLIC IS NOT ALLOWED. 110% CONTAINMENT PER T -1 T -1 AST REGS. EX. BOUNDARY LINE PRIOR TO FUEL DROP, THE G.C. SHALL HAVE THE VEEDER ROOT MONITORING SYSTEM OPERATIONAL. OWNER WILL NOT SCHEDULE ADDITIVE FOR DELIVERY UNTIL THE JURISDICTION HAS AUTHORIZED THE SITE FOR FIRST DROP, VEEDER ROOT IS OPERATIONAL AND MONITORING THE NEW TANK AND THE SITE IS ACCESSIBLE FOR DELIVERY TRUCKS GENERAL NO 1. BOUNDARY INFORMATION SHOWN IS TAKEN DIRECTLY FROM COSTCO GAS STATION PLANS DATED 8/05/08 PREPARED BY BARGHAUSEN CONSULTING ENGINEERS, INC. CONTRACTOR EX. BOUNDARY LINE TO HAVE BOUNDARY LINE ADJACENT TO TANK VERIFIED AND FIELD STAKED BY A _ PROFESSIONAL LAND SURVEYOR PRIOR TO CONSTRUCTION. — CAUTION! POTENTIAL UTILITY CONFLICT, CONTRACTOR SHALL 2. REMOVE EXISTING LANDSCAPING AND RE -ROUTE EXISTING IRRIGATION SYSTEM AROUND FIELD VERIFY ALL EXISTING AND NEW UTILITIES PRIOR TO TANK PAD IMPROVEMENTS AS NECESSARY TO MAINTAIN IRRIGATION TO BOTH SIDES OF CONSTRUCTION. SEE UTILITY CONFLICT NOTE TANK. THE EXISTING WATER, STORM, AND SANITARY SEWER SERVICE SHOWN IS APPROXIMATE, BASED ON FIELD SURVEYS AND "AS- BUILT" RECORDS. 1� =10' 3. ONE OR MORE PORTABLE FIRE EXTINGUISHERS HAVING A RATING OF NOT LESS THAN 40BC THE GENERAL CONTRACTOR SHALL. "POTHOLE" THE EXISTING UTILITIES SHALL BE LOCATED AT /NEAR THE TANK STORAGE AREA PER FIRE DEPARTMENT DIRECTION. TO VERIFY THE DIAMETER AND LOCATION (INCL. ELEVATIONS) PRIOR TO q CONSTRUCTION. ANY DISCREPANCIES IN THE LOCATION OF THE DETAIL SITE PLAN EXISTING PIPE OR INCOMPATIBILITY OF THE DESIGN SHALL BE f-i BROUGHT TO THE IMMEDIATE ATTENTION OF THE OWNERS REPRESENTATIVE, AND BARGHAUSEN CONSULTING ENGINEERS INC. (425- 251 - 6222). :•• ••• UTM CONFXT NOTE CALq : THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION, AND DEPTH OF ALL EXISTING UTILITIES WHETHER SHOWN ON THESE PLANS OR NOT BY POTHOLING THE UTILITIES AND SURVEYING THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. THIS SHALL INCLUDE CALLING UTILITY LOCATE 0 1 -800- 227 -2600 AND THEN POTHOLING ALL OF THE EXISTING UTILITIES AT LOCATIONS OF NEW UTILITY CROSSINGS TO PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST. LOCATIONS OF SAID UTILITIES AS SHOWN ON THESE PLANS ARE BASED UPON THE UNVERIFIED PUBLIC INFORMATION AND ARE SUBJECT TO VARIATION. IF CONFLICTS SHOULD OCCUR, THE CONTRACTOR SHALL CONSULT BARGHAUSEN CONSULTING ENGINEERS, INC. TO RESOLVE ALL PROBLEMS PRIOR TO PROCEEDING WITH CONSTRUCTION. CONDUIT C DUL .� CONDUIT CONDUIT PURPOSE CONDUIT FILL COMMENTS # SIZE 3/4" ADDITIVE TANK FLOW METER 0 •, (1) BELDEN CABLE #88760 FROM CONTROLLER ENCLOSURE TO ADDITIVE AST ZO 3/4" ADDITIVE SOLENOID VALVE WIRING (4) #12 THWN + (1) #12 GND. (24V) FROM CONTROLLER ENCLOSURE TO GASOLINE FILL SUMP 3/4" ADDITIVE SOLENOID VALVE WIRING (3) #12 THWN + (1) #12 GND. (24V) LOOP BETWEEN GASOLINE FILL SUMPS 4� 3/4" ADDITIVE SOLENOID VALVE WIRING (2) #12 THWN + (1) #12 GND. (24V) LOOP BETWEEN GASOLINE FILL SUMPS 3/4" AST ANNULAR, ATG, TRANSITION SUMP (3) BELDEN #88760 & (1) #12 GND FROM CONTROLLER ENCLOSURE TO ADDITIVE AST © 3/4" TURBINE PUMP POWER (2) #10 THWN, (1) #10 GND. FROM CONTROLLER ENCLOSURE TO ADDITIVE TANK TURBINE �l GENERAL NO 1. BOUNDARY INFORMATION SHOWN IS TAKEN DIRECTLY FROM COSTCO GAS STATION PLANS DATED 8/05/08 PREPARED BY BARGHAUSEN CONSULTING ENGINEERS, INC. CONTRACTOR EX. BOUNDARY LINE TO HAVE BOUNDARY LINE ADJACENT TO TANK VERIFIED AND FIELD STAKED BY A _ PROFESSIONAL LAND SURVEYOR PRIOR TO CONSTRUCTION. — CAUTION! POTENTIAL UTILITY CONFLICT, CONTRACTOR SHALL 2. REMOVE EXISTING LANDSCAPING AND RE -ROUTE EXISTING IRRIGATION SYSTEM AROUND FIELD VERIFY ALL EXISTING AND NEW UTILITIES PRIOR TO TANK PAD IMPROVEMENTS AS NECESSARY TO MAINTAIN IRRIGATION TO BOTH SIDES OF CONSTRUCTION. SEE UTILITY CONFLICT NOTE TANK. THE EXISTING WATER, STORM, AND SANITARY SEWER SERVICE SHOWN IS APPROXIMATE, BASED ON FIELD SURVEYS AND "AS- BUILT" RECORDS. 1� =10' 3. ONE OR MORE PORTABLE FIRE EXTINGUISHERS HAVING A RATING OF NOT LESS THAN 40BC THE GENERAL CONTRACTOR SHALL. "POTHOLE" THE EXISTING UTILITIES SHALL BE LOCATED AT /NEAR THE TANK STORAGE AREA PER FIRE DEPARTMENT DIRECTION. TO VERIFY THE DIAMETER AND LOCATION (INCL. ELEVATIONS) PRIOR TO q CONSTRUCTION. ANY DISCREPANCIES IN THE LOCATION OF THE DETAIL SITE PLAN EXISTING PIPE OR INCOMPATIBILITY OF THE DESIGN SHALL BE f-i BROUGHT TO THE IMMEDIATE ATTENTION OF THE OWNERS REPRESENTATIVE, AND BARGHAUSEN CONSULTING ENGINEERS INC. (425- 251 - 6222). :•• ••• UTM CONFXT NOTE CALq : THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION, AND DEPTH OF ALL EXISTING UTILITIES WHETHER SHOWN ON THESE PLANS OR NOT BY POTHOLING THE UTILITIES AND SURVEYING THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. THIS SHALL INCLUDE CALLING UTILITY LOCATE 0 1 -800- 227 -2600 AND THEN POTHOLING ALL OF THE EXISTING UTILITIES AT LOCATIONS OF NEW UTILITY CROSSINGS TO PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST. LOCATIONS OF SAID UTILITIES AS SHOWN ON THESE PLANS ARE BASED UPON THE UNVERIFIED PUBLIC INFORMATION AND ARE SUBJECT TO VARIATION. IF CONFLICTS SHOULD OCCUR, THE CONTRACTOR SHALL CONSULT BARGHAUSEN CONSULTING ENGINEERS, INC. TO RESOLVE ALL PROBLEMS PRIOR TO PROCEEDING WITH CONSTRUCTION. CONDUIT C DUL .� CONDUIT CONDUIT PURPOSE CONDUIT FILL COMMENTS # SIZE 3/4" ADDITIVE TANK FLOW METER 0 •, (1) BELDEN CABLE #88760 FROM CONTROLLER ENCLOSURE TO ADDITIVE AST ZO 3/4" ADDITIVE SOLENOID VALVE WIRING (4) #12 THWN + (1) #12 GND. (24V) FROM CONTROLLER ENCLOSURE TO GASOLINE FILL SUMP 3/4" ADDITIVE SOLENOID VALVE WIRING (3) #12 THWN + (1) #12 GND. (24V) LOOP BETWEEN GASOLINE FILL SUMPS 4� 3/4" ADDITIVE SOLENOID VALVE WIRING (2) #12 THWN + (1) #12 GND. (24V) LOOP BETWEEN GASOLINE FILL SUMPS 3/4" AST ANNULAR, ATG, TRANSITION SUMP (3) BELDEN #88760 & (1) #12 GND FROM CONTROLLER ENCLOSURE TO ADDITIVE AST © 3/4" TURBINE PUMP POWER (2) #10 THWN, (1) #10 GND. FROM CONTROLLER ENCLOSURE TO ADDITIVE TANK TURBINE GENERAL NO 1. BOUNDARY INFORMATION SHOWN IS TAKEN DIRECTLY FROM COSTCO GAS STATION PLANS DATED 8/05/08 PREPARED BY BARGHAUSEN CONSULTING ENGINEERS, INC. CONTRACTOR EX. BOUNDARY LINE TO HAVE BOUNDARY LINE ADJACENT TO TANK VERIFIED AND FIELD STAKED BY A _ PROFESSIONAL LAND SURVEYOR PRIOR TO CONSTRUCTION. — CAUTION! POTENTIAL UTILITY CONFLICT, CONTRACTOR SHALL 2. REMOVE EXISTING LANDSCAPING AND RE -ROUTE EXISTING IRRIGATION SYSTEM AROUND FIELD VERIFY ALL EXISTING AND NEW UTILITIES PRIOR TO TANK PAD IMPROVEMENTS AS NECESSARY TO MAINTAIN IRRIGATION TO BOTH SIDES OF CONSTRUCTION. SEE UTILITY CONFLICT NOTE TANK. THE EXISTING WATER, STORM, AND SANITARY SEWER SERVICE SHOWN IS APPROXIMATE, BASED ON FIELD SURVEYS AND "AS- BUILT" RECORDS. 1� =10' 3. ONE OR MORE PORTABLE FIRE EXTINGUISHERS HAVING A RATING OF NOT LESS THAN 40BC THE GENERAL CONTRACTOR SHALL. "POTHOLE" THE EXISTING UTILITIES SHALL BE LOCATED AT /NEAR THE TANK STORAGE AREA PER FIRE DEPARTMENT DIRECTION. TO VERIFY THE DIAMETER AND LOCATION (INCL. ELEVATIONS) PRIOR TO q CONSTRUCTION. ANY DISCREPANCIES IN THE LOCATION OF THE DETAIL SITE PLAN EXISTING PIPE OR INCOMPATIBILITY OF THE DESIGN SHALL BE f-i BROUGHT TO THE IMMEDIATE ATTENTION OF THE OWNERS REPRESENTATIVE, AND BARGHAUSEN CONSULTING ENGINEERS INC. (425- 251 - 6222). :•• ••• UTM CONFXT NOTE CALq : THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION, AND DEPTH OF ALL EXISTING UTILITIES WHETHER SHOWN ON THESE PLANS OR NOT BY POTHOLING THE UTILITIES AND SURVEYING THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. THIS SHALL INCLUDE CALLING UTILITY LOCATE 0 1 -800- 227 -2600 AND THEN POTHOLING ALL OF THE EXISTING UTILITIES AT LOCATIONS OF NEW UTILITY CROSSINGS TO PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST. LOCATIONS OF SAID UTILITIES AS SHOWN ON THESE PLANS ARE BASED UPON THE UNVERIFIED PUBLIC INFORMATION AND ARE SUBJECT TO VARIATION. IF CONFLICTS SHOULD OCCUR, THE CONTRACTOR SHALL CONSULT BARGHAUSEN CONSULTING ENGINEERS, INC. TO RESOLVE ALL PROBLEMS PRIOR TO PROCEEDING WITH CONSTRUCTION. o QRpFESSIONq! �= HAL P GRUBB q) .� 0 •, �. 1; o QRpFESSIONq! �= HAL P GRUBB q) NOTES: 1. VERIFY SLAB SIZE WITH TANK DRAWING PRIOR TO CONSTRUCTION. 2. CONCRETE SLAB SHALL BE SLOPED TO DRAIN AS SHOWN ON SITE PLAN. 3. CONCRETE SHALL HAVE A MIN. COMPRESSIVE STRENGTH OF 3,000 PSI (DESIGN f'c = 2,500 PSI) AT 28 DAYS. WATER /CEMENT RATIO OF 0.50 MAX. 5 -1/2 SACKS OF CEMENT PER CY MINIMUM. 4• 6" THICK CONCRETE SLAB BASED ON SOIL BEARING CAPACITY OF 1,500 PSF. A ,t 4. mss:; #4 REBAR ® 12" O.C. EACH WAY IN CENTER OF 6" THICK CONCRETE SLAB. 1/2" FIBER BOARD EXPANSION STRIP (BETWEEN TANK SLAB AND CONCRETE PAD W/ SILCONE SEALANT JOINT FILLER 4' Y z CONCRETE PAD M I EXPANSION JOINT W/ JOINT FILLER iff nP SEE DETAIL TOOLED DUMMY JOINT EX. CONCRETE 6" CONCRETE PAD 4 da. SLOPE a 4. ° w a_d z —_ a 0 0 °0 �° 9. C& ci Euoj o° C& ° 92° n °,p° °c& .'4 d s a d .4 1 CONCRETE PAD 8" f'c =2,500 FLUSH CURB DETAIL NOT TO SCALE GUARD POST - LOCATION PER SITE PLAN (TYP.) a4 v • SUMP SHALL BE BEDDED ON 6" MIN. THICK PEA GRAVEL BED 4' -0" CONCRETE PAD L FACE OF TANK Y " 1 TANK I) l 1 I (EXPANSION BOLT (SI PSO STRONG BO T OR HILTI TZ). EMBED 4-1 i 4' -0" MAX. SPACING; 4 d 1/2" FIBER BOARD -' EXPANSION STRIP (BETWEEN TANK SLAB AND CONCRETE PAD) SEE TANK SLAB FOUNDATION DETAIL COMPACT BEARING SURFACE W /PORTABLE MACHINE PLATE COMPACTOR SEE TANK II EL DETAIL 9' 0 -3/8" TANK 11' 0 -3/8" TANK SLAB oTANK SLAB DETAIL NiOT TO SCALE L 4 ABOVE GROUND STORAGE TANK PER SHEET T1. CAST -IN -PLACE CONCRETE CURB s 0 I 1' -0" I� 0 (3) CHANNEL PADS BOTTOM CORNER OF TANK i i TANK CHANNEL PADS (3) ��-- BOLT U TANK CHANNEL DETAIL NOT TO SCALE 4 4- CAST -IN -PLACE it #4 ® 12" O.C. EMBED 3" o• a '. 4 44 9 0-3/8- TANK 11' 0 -3/8" TANK SLAB 2 TANK SLAB SECTION A -A NOT TO SCALE LANDSCAPE AREA A L/S FAI IA I ot jLj�lMjjLMFA . Au ^^Anr' Anr-e COMPACT BEARING SURFACE W /PORTABLE MACHINE PLATE COMPACTOR Ex. CURB TO REMAIN 3 TANK SLAB SECTION -B O T NO TO SCALE 3" ASPHALT CONCRETE PAVEMENT "SCHOOL YARD MIX" 8" BASE COURSE EXISTING SUBGRADE HEAVY TRAFFIC PAVEMENT SECTION NOT TO SCALE 6" MIN. PCC CONCRETE (DESIGN f'c =2,500 PSI, ACTUAL f'c =3,000 PSI) OF CSTC COMPACTED TO 957. OF THE MODIFIED PROCTOR MAXIMUM DENSITY II111�IIFlII„ IIII1 EXISTING SUBGRADE CONCRETE PAD SECTION NOT TO SCALE RADIUS CORNERS, TYP PLANTING PER LANDSCAPE DRAWINGS 5/8" DIA. EXPANSION BOLT TANK CHANNEL PADS (3) (HILTI TZ STAINLESS STEEL) iff nP SEE DETAIL 4 da. ° w a_d —_ a . _� ci Euoj .'4 d s a d .4 1 CONCRETE PAD 8" f'c =2,500 PSI FACE OF TANK MIN. #4 ® 12" O.C. EACH WAY fb= 40,000 PSI „I I II I I I I, ;,I I II II I I I I I I I: III =1I I- III -1I I�I I I- III -I I1= 1 =1 11 =1 11 =1 11 =1 11 =1 11 =1 1 1=111 �- °� a I= I I= I 1 =1 11= 11 =1 1=1 I I- 00� ° , cp I I I I I I =1 11 =1 11= 1= 1- Ili I I I =I I 1=1 l I— 11=1 11 =1 I I == I I_ I I -1 11 =1 l 1 =1 11 =1 l l =�l =11 =111 =1I �Ilii�Ill�►�III���I itlliiitl��Il— — IIII111I1 111 , II NOTES: #4 BARS CONT. 1. PROVIDE EXP. JOINTS AT 25' O.C. AND ® THE TOP AND START AND FINISH OF ALL CURVED SECTIONS BOTTOM 2. PAINT CURBS WHERE NOTED ON SITE PLAN 3. VERIFY CURB DEPTHS AND SUBGRADE PREPARATION W/ CIVIL ENGINEER DRAWINGS o6 CAST -IN -PLACE CONCRETE CURB NOT TO SCALE SEE TANK SLAB FOUNDATION DETAIL EXISTING SUBGRADE NOT TO SCALE PLASTIC CAP GUARD POST: 6"o STD. PIPE CONCRETE FILLED & COVERED WITH RED PLASTIC SLEEVE 4' -0" CONCRETE FOOTING --- NOTE: EX. GUARD POSTS ONSITE HAVE YELLOW PLASTIC SLEEVES OTYPICAL GUARD POST NOT TO SCALE ii iff NOTE: ASPHALT PAVEMENT PATCH, MATCH EXISTING ALL MANHOLES ON THE TANK SLAB SHALL BE INSTALLED WITH A CROWN OF MATERIALS AND THICKNESS WHICHEVER IS GREATER. CONCRETE THAT MATCHES EXISTING TO PREVENT WATER INTRUSION INTO THE MANHOLE. THE OWNER'S ENGINEER WILL BE REQUIRED TO SIGN OFF ON THIS ITEM LL ON THE TANK INSTALLATION CHECKLIST BEFORE CONTRACTOR' WILL BE PAID. LANDSCAPE AREA -MULCH CONTRACTOR WILL BE REQUIRED TO REINSTALL ENTIRE DRIVE SLAB AT OWN AND TOPSOILS AS PER L1; Q¢OF E S SI pNq EXPENSE IF THIS DESIGN REQUIREMENT IS NOT MET. MIN. 3" MULCH OVER 4" �� 4,1 NEAT LINE SAWCUT PRIOR =G' c� TO PAVEMENT PATCH WITH TOPSOIL HAL , . G ?, CONCRUE SLAB SPECIFICATIONS HOT TAR SEAL LANDSCAPE AREA 6 14 rn BACKFILL W COMPETENT 1. UNLESS OTHERWISE NOTED ON THESE DRAWINGS: NATIVE MATERIAL REPLACE a. CONCRETE - REGULAR WEIGHT HARD ROCK CONCRETE (150 LBS /CU FT) \ \\ \\ \ IN LIKE KIND. COMPACT 6/,7 b. CEMENT - TYPE II, SULFATE RESISTANT TO 90% RELATIVE X 0 /k �Q c. AGGREGATES - ASTM C33, (MAXIMUM SIZE 3/4 INCHES) POWER A Z. DENSITY. TRAFFIC AREAS q� p 1 V 1 d. 28 DAY CONCRETE STRENGTH (f c): CONTROL CONDUITS BACKFILL WITH 5/8" 3,000 PSI - SLAB (DESIGN BASED ON 2,000 PSI NO SPECIAL INSPECTION REQUIRED) PER PLAN C3 \ \/ MINUS CRUSHED TOP e. SLUMP - 3 "+ 1" - 4" MAXIMUM AT POINT OF PLACEMIENT 4" MIN. CDF CAP PER /\ .. \ \� COARSE AND COMPACT x STATE DOT STANDARDS f. SHRINKAGE - 0.05% MAXIMUM * // TO 95% MAX. RELATIVE o g. ENTRAINED AIR RANGE - 4% TO 7% " j/\ .. < ° \�j N DENSITY. c ` ` o 2. CONCRETE SHALL BE NORMAL WEIGHT WITH A MIX OF t : 2 1/2:3 1/2, WITH A MAXIMUM 4 CLR. .S_ z z m v� o ) m 7 1/2 GALLONS OF WATER PER SACK. (NP') Lj * TO BE INSTALLED IN a .0 .,0.,. 0: 4" MIN. 3. REINFORCING STEEL FOR TANK SLABS SHALL BE #4 REBAR @ 18" (D.C. BOTH WAYS LOCATIONS WHERE PIPING t _ SUMP CAGES SHALL BE #4 REBAR TOP AND BOTTOM (4 BARS). RUN THROUGH LANDSCAPE 4 "� \'i / / / / a ~ = N _ (TY) I cv 4. MAINTAIN CONCRETE IN A MOIST CONDITION FOR AT LEAST 7 DAYS AFTER PLACEMENT. AREAS. P. 24" MAX o _ II 5. PLACE CONCRETE DIRECTLY FROM TRUCK INTO FORMS. DO NOT PUMP CONCRETE UNLESS 12" MIN T � u o � SPECIAL INSPECTION, IN ACCORDANCE WITH CHAPTER 3 OF THE UBC, IS PROVIDED. L ° ° " 1 n u a a 6. CONSOLIDATE CONCRETE IN PLACE USING A MECHANICAL VIBRATOR. V) NOT TO SCALE w :E cl- 7. BEFORE PLACING CONCRETE, SECURE REINFORCING STEEL, ANCHOR BOLTS, DOWELS, AND = u OTHER INSERTS IN POSITION TO PREVENT MOVEMENT. NOTES: z > N 8. MATERIALS AND WORKMANSHIP SHALL CONFORM TO A.C.I. - 318 (SPECIFICATIONS OF THE 1. PROVIDE PULL BOXES (SIZE PER CODE) FOR CONDUITS AS REQUIRED FOR o a J DESIGN AND PLACEMENT OF CONCRETE). EVERY 250 OR AFTER A TOTAL OF 270 DEGREES OF BENDS. w a o X d Z FILL W/ JOINT SEALER 2. PROVIDE SUFFICIENT ADDITIONAL LENGTH OF CONDUCTORS W NEW CONCRETE AT THE TERMINATION POINTS OF ALL CONDUITS FOR FINAL > z PAVEMENT EXISTING CONCRETE PAVEMENT EQUIPMENT HOOKUP. Q a N oo ( co N r-- - Z B I' r 3. SUPPLY AND INSTALL ALL CONDUITS /CONDUCTORS AND z w W A 25 LB. PULL WIRE IN EACH SPARE FUTURE CONDUIT. N z o /) /� o V ^CN WW 2'-0 3/4 "0x15" SMOOTH DOWELS CV N N @ 15" O.C. CENTERED co Lj d- d > 5 o v cn I JOINT /`T TANK SLAB (D JOINT (OILED} _o ` V NOT TO SCALE `St> o 7" CONCRETE TANK SLAB 1)� Q MATCH EX. CROWN �$" �a„ #4 @ 18" O.C. BOTH WAYS EXISTING CONCRETE PAVEMENT TO REMAIN "''u S- W/ a (TYP, ALL) (TYP,) Lu At Zz W 9 c 3" MIN. CO -- - - SAWCUT AND MATCH WITH C° AROUND ALL PENETRATIONS (TYP.) EXISTING PER JOINT AT TANK o SLAB DETAIL BELOW. LOCATION PER PLAN SHEET C3 m % PEA GRAVEL z = o 0 EXISTING CONCRETE TANK SLAB REPAIR /REPLACEMENT SECTION N CD NOT TO SCALE °-' LANDSCAPE PLANTING NOTES AND MATERIALS SCOPE OE= WORK 1. FURNISH ALL MATERIALS, LABOR, EQUIPMENT AND RELATED ITEMS NECESSARY TO ACCOMPLISH THE TREATMENT AND PREPARATION OF SOIL, FINISH GRADING, PLACEMENT OF SPECIFIED PLANT MATERIALS, FERTILIZER, STAKING, MULCH, CLEAN -UP, AND DEBRIS REMOVAL. 2. QUALIFICATIONS: LANDSCAPE CONTRACTOR TO BE SKILLED AND KNOWLEDGEABLE IN THE FIELD OF WORK AND HAVE A MINIMUM OF FIVE (5) YEARS EXPERIENCE INSTALLING SIMILAR WORK. CONTRACTOR TO BE LICENSED TO PERFORM THE WORK SPECIFIED WITHIN THE PRESIDING JURISDICTION. 3. JOB CONDITIONS: IT IS THE CONTRACTOR'S RESPONSIBILITY TO REVIEW THE SITE AND REPORT ANY DISCREPANCIES TO THE OWNER. ALL PLANT MATERIAL AND FINISH GRADES ARE SUBJECT TO APPROVAL BY THE OWNER. 4. PROTECTION: SAVE AND PROTECT ALL EXISTING PLANTINGS SHOWN TO REMAIN. DO NOT PLANT UNTIL OTHER CONSTRUCTION OPERATIONS WHICH CONFLICT HAVE BEEN COMPLETED. DO NOT PLANT UNTIL THE IRRIGATION SYSTEM HAS BEEN MODIFIED AND TESTED. HANDLE PLANTS WITH CARE - DO NOT DAMAGE OR BREAK ROOT SYSTEM, BARK, OR BRANCHES. REPAIR AND /OR REPLACE ITEMS DAMAGED AS A RESULT OF WORK, OR WORK NOT IN COMPLIANCE WITH PLANS AND SPECIFICATIONS, AS DIRECTED BY OWNER AT NO ADDITIONAL COST. 5. REPAIR OF EXISTING PLANTINGS: DURING THE COURSE OF WORK, REPAIR ALL EXISTING PLANTING AREAS DAMAGED BY NEW CONSTRUCTION. RE- ESTABLISHING FINISH GRADE AND RE- MULCHING TO SPECIFIED DEPTH. 6. REPAIR OF EXISTING IRRIGATION SYSTEM: DURING THE COURSE OF WORK, REPAIR ALL EXISTING IRRIGATION SYSTEM DAMAGED BY NEW CONSTRUCTION AND RE- ESTABLISHNG FINISH GRAD. 7. MATERIALS: PLANT MATERIALS: PLANT MATERIALS TO BE GRADE NO. 1; SIZED IN ACCORDANCE WITH (AAN) AMERICAN STANDARDS FOR NURSERY STOCK (ANSI Z60.1- 1996). PRUNE PLANTS RECEIVED FROM THE NURSERY ONLY UPON AUTHORIZATION BY THE OWNER. "CONT." INDICATES CONTAINER; AND "GAL" INDICATES GALLON. A) SPECIFIED PLANT CANOPY SIZE OR CALIPER IS THE MINIMUM ACCEPTABLE CONTAINER OR BALL SIZE ESTABLISHES MINIMUM PLANT CONDITION TO BE PROVIDED. B) QUALITY: PLANT MATERIAL TO COMPLY WITH STATE AND FEDERAL LAWS FOR DISEASE INSPECTION, PLANTS TO BE FULLY LIVE, VIGOROUS, WELL FORMED, WITH WELL DEVELOPED FIBROUS ROOT SYSTEMS. ROOT BALLS OF PLANTS TO BE SOLID AND FIRMLY HELD TOGETHER, SECURELY CONTAINED AND PROTECTED FROM INJURY AND DESICCATION. PLANTS DETERMINED BY LANDSCAPE ARCHITECT TO HAVE BEEN DAMAGED; HAVE DEFORMITIES OF STEM, BRANCHES, OR ROOTS, LACK SYMMETRY, HAVE MULTIPLE LEADERS OR "Y" CROTCHES LESS THAN 30 DEGREES IN TREES, OR DO NOT MEET SIZE OR ANSI STANDARDS WILL BE REJECTED. PLANT MATERIAL TO BE FROM A SINGLE NURSERY SOURCE FOR EACH SPECIFIED SPECIES /HYBRID. NURSERY SOURCES TO BE THOSE LOCATED IN THE SAME REGION AS THE JOB SITE. C) SUBSTITUTION: NO SUBSTITUTION OF PLANT MATERIAL, SPECIES OR VARIETY, WILL BE PERMITTED. SUBSTITUTIONS WHICH ARE PERMITTED TO BE IN WRITING FROM THE OWNER. THE SPECIFIED SIZE, SPECIES AND NEAREST VARIETY, AS APPROVED, TO BE FURNISHED.. SUBSTITUTIONS MAY REQUIRE RE- SUBMITTAL OF A REVISED LANDSCAPE PLAN TO CITY FOR APPROVAL. 8. SOIL PREPARATION: AMENDED NATIVE SOIL ARE REQUIRED FOR ALL NEW AND DISTURBED LANDSCAPE ARES. A) NATIVE SURFACE SOIL NATIVE SOIL TO BE USED FOR BACK FILL AND AMENDED AS INDICATED BELOW. B) AMENDMENT 1.. SOIL FOR PLANTING AREAS SHALL CONTAIN A MINIMUM OF 10 PERCENT ORGANIC MATERIAL BY VOLUME. 2. ORGANIC COMPOST USE BULK NITROGEN FORTIFIED GROUND FIR BARK SATISFYING THE ORGANIC MATERIAL REQUIREMENTS. COMPOST SHALL BE FREE FROM NON -FARM ANIMAL SOURCES, NOR FROM SOURCES CONTAINING REDWOOD /CEDAR PRODUCTS. 3. FERTILIZER INSTALLATION FERTILIZER SHALL BE 6- 20 -20. MAINTENANCE FERTILIZER SHALL BE 21 -0 -0. AGRIFORM TABLETS SHALL BE 21 AND 5 GRAM SIZE, 20 -10 -5 BY AGRIFORM INTERNATIONAL CHEMICALS, INC. OR EQUIVALENT. 4. SOIL AMENDMENTS SOIL SULFUR 20 POUNDS PER 1,000 SF ORGANIC AMENDMENT 4 CUBIC YARDS PER 1,000 SF N -P -K FERTILIZER 10 POUNDS PER 1,000 SF C) PLANTING BACKFILL BACKFILL MIX FOR TREES, SHRUBS, AND GROUNDCOVERS SHALL BE PREMIXED AND CONSIST OF: SITE SOIL 0.8 CUBIC YARDS ORGANIC AMENDMENT 0.2 CUBIC YARDS FERTILIZER 6 -20 -20 1.0 POUND IRON SULFATE 2.0 POUNDS SLOW RELEASE FERTILIZER TABLETS: CONTAINER SIZE # OF TABLETS FLAT 1 - 5 GRAM 1 GALLON 3 - 5 GRAM 5 GALLON 3 - 21 GRAM 15 GALLON 16 - 21 GRAM 24" BOX 32 - 21 GRAM D) TOPSOIL PREPARATION REMOVE FROM SITE ALL WEEDS AND DEBRIS WITHIN ALL PROPOSED LANDSCAPE AREAS. DO NOT WORK SOIL WHEN MOISTURE CONTENT IS SO GREAT THAT EXCESS COMPACTION WILL OCCUR NOR WHEN IT IS SO DRY THAT DUST WILL FORM IN THE AIR OR THAT CLODS WILL NOT BREAK READILY. APPLY WATER IF NECESSARY TO PROVIDE IDEAL MOISTURE CONTENT FOR FILLING AND PLANTING AS SPECIFIED. REMOVE ALL SURFACE LUMPS, ROCKS, VEGETATION, AND /OR DEBRIS LARGER THAN 1 -INCH FROM ALL PLANTING GRADES PRIOR TO ANY PLANT INSTALLATION. FINISH GRADE ALL PLANTING AREAS TO A SMOOTH, UNIFORM SURFACE DRAINING AWAY FROM TANK PAD. FINISH GRADE TO BE 2 INCHES IN MULCH AREAS BELOW FINISH SURFACE OF ADJACENT PAVEMENT. FINISH GRADES TO BE APPROVED PRIOR TO PLACEMENT OF ANY PLANT MATERIAL. 9. MULCH: NITOLIZED BROKEN BARK MULCH, SHREDDED WOOD WILL NOT BE ALLOWED. MATCH EXISTING MULCH IN MATERIAL, SIZE, TEXTURE, AND COLOR. EXECUTION: 10. FINISH GRADES: FINE GRADE AND REMOVE ROCKS AND FOREIGN OBJECTS OVER TWO INCHES (2 ") DIAMETER FROM TOP THREE INCHES (3") OF PREPARED PLANTING BED. FINISH ELEVATION TO BE DEFINED AS THREE (3 ") BELOW PAVEMENT. ALL FINISH GRADES TO BE SMOOTH EVEN GRADES, LIGHTLY COMPACTED, AS SHOWN ON THE PLAN AND DETAILED. SITE CIVIL DRAWINGS IDENTIFY FINAL ELEVATIONS. 11. SHRUBS, AND GROUNDCOVERS: ARRANGE SHRUBS AND GROUNDCOVERS ON SITE IN PROPOSED LOCATIONS PER DRAWINGS. EXCAVATE PIT, PLANT AND STAKE AND GUY AS CALLED OUT AND DETAILED. ALL SHRUBS TO STAND VERTICAL. BACK FILL SHALL BE PIT SPOILS. SETTLE BACKFILL USING WATER ONLY. NO MECHANICAL COMPACTION. PROVIDE TREE ROOT BARRIER ON BOTH SIDES OF TREE, 10 FOOT LENGTH CENTERED ON TREE TRUNK. 12. MULCH: MULCH NEW AND DISTURBED LANDSCAPE AREAS. APPLY SUFFICIENT QUANTITY TO PROVIDE A MINIMUM TWO INCH (2 ") DEPTH. MATCH EXISTING LAYER DEPTH. 13. FERTILIZATION FOR GROUNDCOVER AREAS: UNIFORMLY BROADCAST SULFUR COATED UREA AT THE RATE OF FIVE (5) LBS. PER 1,000 SQUARE FEET. THE FIRST APPLICATION TO OCCUR APPROXIMATELY FORTY -FIVE (45) DAYS AFTER PLANTING. IN EARLY FALL AND SPRING, SUBSTITUTE A COMPLETE FERTILIZER SUCH AS 16 -6 -8 OR EQUIVALENT FOR THE SULFUR COATED UREA AT THE RATE OF SIX (6) LBS. PER 1,000 SQUARE FEET. FOLLOW EACH FERTILIZATION WITH A THOROUGH IRRIGATION APPLICATION. 14. IRRIGATION: THE MODIFIED IRRIGATION SYSTEM TO BE ADJUSTED FOR BALANCED, WATER DISTRIBUTION, AND PRECIPITATION. FAILED OR MALFUNCTIONING IRRIGATION EQUIPMENT TO BE REPLACED AND /OR CORRECTED. 15. EXISTING CONDITIONS: THIS PLAN HAS BEEN PREPARED WITH THE BENEFIT OF A LANDSCAPE PLAN BY NOWELL & ASSOCIATES SAN DIEGO, CA; CONTRACTOR TO VERIFY ALL CONDITIONS PRIOR TO STARTING ANY WORK AND NOTIFY OWNER OR ANY CONFLICTS. PLACE IN VERT. POSITION NOTE: KEEP ROOTBALL MOIST AND PROTECTED AT ALL TIMES. HOLD CROWN OF ROOTBALL AT OR JUST ABOVE FINISH GRADE. BACKFILL TO BE SETTLED USING WATER ONLY NO MECHANICAL COMPACTION. HOLD MULCH BACK 6" FROM SHRUB BASE FINISH GRADE PREPARE PLANTING BED PER SPECS; PIT TO BE 2 TIMES BALL DIA. REMOVE ALL WRAP. TIES. AND CONT/ SCORE ROOTBALL AND WORK NURSEI FROM PERIMETER ROOTS SET BALL ON UNDISTURBED BASE Of COMPACTED MOUND UNDER BALL PENETRATION TO SUBBASE ( +) 24" uun +uut��uu� y :rr NOT TO SCALE HOLD PLANT' EDGE OF Pb AS NOTED 01 LEGEND BED LINE ED CURB /WALK HOLD PLANTS r rwm EDGE OF PLANTER AS NOTED ON PLANT LIST PLANT MATERIAL SPACING DETAIL NOT TO SCALE MULCH AT CURB DETAIL NOT TO SCALE SPACING AS CALLED OUT IN LEGEND it MIN. MULCH LAYER, MATCH EXISTING MULCH -AYER DEPTH 1" MAX. TOP OF CURB TO TOP OF MULCH EX. VENT STACK EX. HEALY CLEAN AIR SEPARATOR UNIT CONCRETE PAD ABOVEGROUND ADDITIVE STORAGE TANK EX. BOUNDARY LINED EXISTING TREE TO REMAIN — TYPICAL LANDSCAPE PLANT MATERIAL LEGEND SYMBOL BOTANICAL /COMMON NAMES SIZE 501 TREES: EXISTING TREE SHRUBS: NERIUM OLEANDER 'MRS. ROEDING' / 15 GALLON MRS. ROEDING PINK OLEANDER GROUNDCOVERS: ACACIA REDOLENS / 1 GALLON NO COMMON NAME MULCH EXISTING LANDSCAPE AND IRRIGATION AUJU51, MUUII -Y ANU/UK KLI'iAIK tAlZ)HINlw InrauHiiuly SYSTEM AS REQUIRED BY NEW CONSTRUCTION, TANK, PAD, CONDUITS, AND PLANTING RESTORATION — TYPICAL REMOVE EXISTING PLANT MATERIAL AS REQUIRED BY NEW CONSTRUCTION, TANK, PAD, CONDUITS, AND PLANTING RESTORATION — TYPICAL PROVIDE A SMOOTH AND LEVEL TRANSITION BETWEEN NEW FINISH GRADE LAND EXISTING FINISH GRADE — TYPICAL SPACING QUANTITY REMARKS 5' O.C. 14 3' O.C. AS REQ'D COVER TO REMAIN, SAVE AND PROTECT HOLD 3' FROM BORDERS AND SHRUBS STOP l d t '�:.� , I EX. BOUNDARY LINE MATCH EXISTING MATERIAL AND DEPTH, VERIFY MATERIAL AND DEPTH ON SITE TO REMAIN, SAVE, PROTECT, AND /OR REPAIR AS REQUIRED BY NEW CONSTRUCTION I DENOTES LINE OF TRANSITION BETWEEN NEW CONSTRUCTION AND EXISTING CONDITIONS \ a� � o o z 9 III J c N = > 0 0 04 • • o V C z ZD Z� • �V) • • J H co Z LZ w O N 00 z x Z — � Q00 0000 Ofz 04 Q I i Zw w — r♦ 0 Lo N a— N C-4 co = e�d/ C) V) z z 1 • co • LC 00 m cr) • Oil \ a� � o o z 9 III J c N = > 0 0 04 • • o V C z ZD Z� • �V) • • J H co o \.glDS CA o M se q��y 0." 1539 F C. -�( Stgrf ure 7� ��TF e,...p. Date �I a� rn c o = > 0 0 O N O u N V) 0 O CA =II V C z ZD �I a� rn c o = > 0 N = V) c.� v ZD Z� �V) W J H Q Z LZ w O N 00 z x Z — � Q00 0000 Ofz 04 Q I i Zw w — Lo N ZLo N C-4 >� = e�d/ C) V) E +� z c o z s ® N o I' I I I a� X J w 0 w II ai a U V) r? (14 C) CV r` 0 a .n J i 00 0 i V a� a a c a� c 00 0 0 0 0 0 Q A 15 GALLON LOCKABLE FILL 5 BOX WITH 2" FITTINGS 2" FILL CAP & 2 3 ADAPTOR VEEDER -ROOT TANK ANNULAR 54 SENSOR AND 2" CAP SINGLE WALL FIBERGLASS TRANSITION SUMP 19 FRP BONDED II I I FITTING (TYP.) 3 4 62 II I I — I 3" OVER 2" D.W. 1 2 76 70 II FRP PRODUCT II SUPPLY LINE LIQUID SUMP SENSOR 50 FLOW METER 14 1-1/2" FIRE VALVE 10 TANK GROUNDING LUG #6 STRANDED WIRE TO 1/2 "0 CADWELD OR COMPRESSION GROUND ROD CONNECTION 3/4 H.P. TURBINE WITH 95 13 MECHANICAL LINE LEAK DETECTOR 1 -1/2" BALL VALVE 12 1-1/2" FIRE VALVE 6o FLOW METER ( 14 TANK ANCHORING LOCATION (TYP. 6 LOCATION) 51 (5:2)(53 4" AUTOMATIC TANK + GAUGE 2" KRUEGER MECHANICAL I GAUGE 2" PRIMARY WORKING VENT + + ® + + 13 95 6" SECONDARY 3/4 H.P. TURBINE WITH 7 EMERGENCY VENT ® MECHANICAL LINE LEAK ® DETECTOR $ 6" PRIMARY EMERGENCY VENT 2 SPARE BUNG. USE AS OPTION FOR MANUAL EXTRACTION PORT FOR FUTURE HAND EXTRACTION II ® II 12 1-1/2" BALL VALVE 1/2" 0 X 10' LONG COPPER CLAD STEEL GROUND ROD IN NATIVE SOIL SCALE: 3/4 " =1' -O" rol mill 17 2 "X1 -1/2" HEX BUSHIING HIGH VOLTAGE 85 J -B(OX -!)PRIMARY TANK VENT RISER FLOW VOLTAGE J -BOX TANK SLAB SEE SHEET C4 8 6" PRIMARY EMERGENCY VENT z ILL 6" SECONDARY 7 EMERGENCY VENT o N 4 d Q d 4 0' OVERFILL PREVENTION E DROP TUBE WITH 3" FLOAT 1,200 GALLON TANK UL2085 "PROTECTED" - -3/4" POWER CONSTRUCTION CONDUIT (LUBRIZOL ADDITIVE) i-- 3/4" MONITORING CONDUIT 9, -08» n g_18. "- 85 SEAL -OFF A 0 1 w1k FIRE RATED MATERIAL FILL (TYP. CAPPED) CAP OR PLUG ALL SPARE OPENINGS 1-1/2" COUPLING FRP BANDED FITTING (TYP.) 3 4 62> - 3" OVER 2" D.W. 1 2 76 70 FRP PRODUCT 5 SUPPLY LINE 2" BELL X MALE ADAPTER 75 LIQUID SUMP SEN 4 2" SPARE BUNG. INSTALL 2 "X1" HEX BUSHING AND 1" SUCTION STINGER, 1" NIPPLE AND CAP. FOR FUTURE HAND EXTRACTION CAP OR PLUG ALL SPARE OPENINGS PRIMARY TANK 6 VENT RISER 3/4 H.P. TURBINE WITH /95X13 MECHANICAL LINE LEAK DETECTOR /\ 6" PRIMARY EMERGENCY / VENT (BEYOND) 7 6" SECONDARY EMERGENCY VENT o�o 51 52 VEEDER -ROOT TANK LEVEL GAUGE 53 •a 4 IIII I I a OVERFILL PREVENTION 'a IIII II .. 4 DROP TUBE WITH 2" IIII II FLOAT 1111 / I i II •a 4 . 1I IIII / Lr- _ioo 2 KRUEGER 5' -78" I I II 9 GAUGE (BEYOND) _ I i SECONDARY TANK I I II CAST -IN -PLACE (CONCRETE CURB 6'_2" I I II a (3) 1-1/2" PIPE SLEEVES OVERALL TANK u e a 1-100 e a (3) 3/4" CONDUITS 85 -� ... -�—'4 -�. TO EX. VENT AREA BOTTOM OF PIPE SLEEVE TO BE SET 1/2" MIN. it ABOVE TOP OF TANK SLAB. 5' -A TANK (OUTSIDE FACE) PRIMARY TANK E VENT RISER 6" PRIMARY 8 EMERGENCY VENT 2" KRUEGER GAUGE WEEDER -ROOT TANK 51 52 53 LEVEL GAUGE INTEGRAL HAND DRAIN PUMP 3/4 H.P. TURBINE WITH 13 95 MECHANICAL LINE LEAK DETECTOR 14 FLOW METER 11 3/4" ANTI - SYPHON VALVE HIGH VOLTAGE 85 J -BOX 85 DATA J -BOX S 1 -1 /2 "x3/4" REDUCER (TYP.) LOW VOLTAGE 85 J -BOX TANK SLAB SEE SHEET C4 15 GALLON LOCKABLE FILL 5 I IIII SPECIFICATIONS.. ALL SUBSTITUTES MUST BE APPROVED BY MANUFACTURER AND OWNER'S FIELD REPRESENTATIVE. 1 -1/2" PIPING AND BOX WITH 2" FITTINGS 0 6" COMPACTED PEA GRAVEL BEDDING. PIPING SHALL NOT BE IIII IIII SUPPORTED BY BLOCKS, PLANKS, OR OTHER DEBRIS. ENTRIES TO BE PERPENDICULAR TO CONTAINMENT SUMP, FITTINGS FOLLOW MANUFACTURER'S INSTALLATION INSTRUCTIONS FOR I I NII FRP PENETRATION FITTINGS SHOWN. ALTERNATE FITTINGS MAY NOT BE USED. 3/4" MONITORING CONDUIT, 3/4" CONTAINMENT FOR ALL PRODUCT PIPING PREPARATION AND INSTALLATION OF NEW BRAVO TRANSITION SUMP IIII AND PIPING PENETRATION FITTING TO BE PER THE MANUFACTURES RECOMMENDATION AND TESTING PROCEDURES. FIBERGLASS WRAP THE POWER CONDUIT & 3/4" DATA 2" FILL CAP & I 1111 KITS TO BE SUPPLIED BY COSTCO. CONDUIT FROM FLOW METER ADAPTOR 2 3 I II I 3 5' -78" I II SECONDARY I A NEW FLAME ARRESTOR IN SUMP 20 II 6' -2" I I 85 SEAL -OFF CAST - IN -PLACE OVERALL TA CONCRETE CURB -100 _ ' . (2) 1-1/2" PIPE SLEEVES r-loo a: TANK SLAB o• SEE SHEET C4 � -4t'. °• •. a n p a —Ar aD n (3) 3/4" CONDUITS o p 0 85 TO X. VENT AREA 00, \ ° o 3 4 62 BOTTOM OF PIPE SLEEVE FRP BONDED TO BE SET 1/2" MIN. FITTING (TYP.) ABOVE TOP OF TANK SLAB. 1-1/2" X 15" FLEX CONNECTOR 18 1 2 2" FEMALE X 1 -1/2" MALE SWIVEL 5 76 70 0 m 50 LIQUID SUMP SENSOR 3" OVER 2" D.W. FRP PRODUCT SUPPLY LINE 5' -78.� 6 SINGLE WALL FIBERGLASS 19 TRANSITION SUMP TANK (OUTSIDE FACE) und Addftive Tank End 7 7 ... ®— NOTES GRAVEL BACKFILL PURSUAN T TO MANUFACTURER'S OPEA SPECIFICATIONS.. ALL SUBSTITUTES MUST BE APPROVED BY MANUFACTURER AND OWNER'S FIELD REPRESENTATIVE. OPIPING SHALL BE LAID AND CONTINUOUSLY SUPPORTED ON A 0 6" COMPACTED PEA GRAVEL BEDDING. PIPING SHALL NOT BE SUPPORTED BY BLOCKS, PLANKS, OR OTHER DEBRIS. ENTRIES TO BE PERPENDICULAR TO CONTAINMENT SUMP, OALL FOLLOW MANUFACTURER'S INSTALLATION INSTRUCTIONS FOR MAXIMUM ANGLE ALLOWANCE. OBRAVO FRP PENETRATION FITTINGS SHOWN. ALTERNATE FITTINGS MAY NOT BE USED. OSECONDARY CONTAINMENT FOR ALL PRODUCT PIPING PREPARATION AND INSTALLATION OF NEW BRAVO TRANSITION SUMP 6 AND PIPING PENETRATION FITTING TO BE PER THE MANUFACTURES RECOMMENDATION AND TESTING PROCEDURES. FIBERGLASS WRAP THE OUTSIDE OF ALL NEW PENETRATION FITTINGS WITH FOUR LAYERS OF FIBERGLASS. ALL BRAVO PENETRATIONS, GLUE AND FIBER GLASSING KITS TO BE SUPPLIED BY COSTCO. 9 • 0 a 1 EXISTING SUMP SENSOR TO REMAIN EXISTING SUMP SENSOR REMOVE & REINSTALL EXISTING PIPE TO REMAIN FITTINGS EXISTING EXPLOSION PROOF JUNCTION BOX TO REMAIN EXISTING EXPLOSION PROOF EXISTING 48" DIA. SUMP JUNCTION BOX TO REMAIN EXISTING FIBERGLASS CONTAINMENT SUMP TO EXISTING ENTRY BOOT REMAIN EXISTING ENTRY BOOT REINSTALL EXISTING FRANKLIN TO REMAIN TO REMAIN FUELING /PHIL —TITE SWIVEL VAPOR ADAPTER REMOVE & REINSTALL EXISTING & MORRISON BROTHERS CAP (TYP.) 0 ° FRANKLIN FUELING /PHIL —TITE STAGE 1 0 ° EXISTING 80 CF SUMP FLAME / VAPOR RECOVERY ASSEMBLY NEW 22" MANWAY PLATE COVER 31 ARRESTOR TO REMAIN ° o REMOVE & REINSTALL EXISTING ° 100 NEW 2" X 3/4" BELL REDUCER REMOVE AND REPLACE SUMP FLAME ARRESTOR (TYP.) EXISTING MANWAY PLATE f o 0 COVER. SEE SHEET T -3 FOR REMOVE AND REINSTALL EXISTING REINSTALL EXISTING FRANKLIN 75 NEW 2" FRP BELL X MALE ADAPTOR PROCEDURE ° � � FUELING /PHIL —TITE SWIVEL FILL ADAPTER O O EXTRACTOR FITTING & BALL FLOAT & MORRISON BROTHERS CAP (TYP.) / 0 9 11 61 NEW BRAVO BONDED o o PENETRATION FITTING EXISTING FRANKLIN REMOVE & REINSTALL NEW 2 >, PLUG (BY G.C.) — 5 REMOVE AND REINSTALL EXISTING / FUELING /PHIL —TITE FILL ° 0 3"x18" FLEXIBLE CONNECTOR NEW 3/4" FLEX CONNECTOR 35 ° o o \ 6 85 NEW 3/4" CONDUIT TO ASSEMBLY o o ` o© 0 \ 85 CONTROLLER ENCLOSURE EXISTING 2" OR 3" 90° ELBOWS I ( NEW 3/4`' CONDUIT TO 85 6 1— I \ 0 1 p EXISTING 3" BELL x MALE CONTROLLER ENCLOSURE 01 THREADED 150# M.I., BLACK TO ADAPTER TO REMAIN \ " REMAIN (TYP.) NEW BRAVO BONDED NEW 3 OVER 2 DOUBLE PENETRATION FITTING 61 5 9 1 1 \ \ \ \ PIPING FIBROMLTRANSROODN CT EXISTING 4x3 CONTAINMENT TERMINATION FITTING W/ TEST NEW SEAL —OFF AND EXPLOSION 85 SUMP PORT TO REMAIN (TYP.) PROOF J —BOX 1 I 1 I I 9 1 1 63 NEW BRAVO BONDED PIPE EXISTING SMITH FIBERCAST 4" OVER I 1 EXISTING 4" SUMP PENETRATION ( I 5 PENETRATION FITTING WITH TEST PORT 3" FRP PIPING TO REMAIN (TYP.) FITTING TO REMAIN (TYP.) I EXISTING 4" OVER 3" FRP PIPING TO REMAIN (TYP.) EXISTING 3" BELL x MALE ADAPTER TO REMAIN NIf1TF- ® - NOTES O2 "' CROWN INSTALLED AT ALL MANHOLE ACCESS OREINFORCEMENT TO BE #4 @ 18" O.C. BOTH WAYS OREINFORCING BARS TO BE NO LESS THAN 2" AND NO MORE THAN 4 "' FROM SURFACE. CONCRETE SLAB AROUND MANHOLE WITH 4 — #4 REBAR OREINFORCE 4 60" IN LENGTH, PLACE REBAR 6" FROM SIDES OF BOX. AND INSTALLATION OF NEW BRAVO CONDUIT AND PIPING OPIREPARATION PENETRATION FITTINGS TO BE PER THE MANUFACTURE'S RECOMMENDATIONS AND TESTING PROCEDURES. FIBERGLASS WRAP THE OIUTSIDE OF ALL NEW PENETRATION FITTINGS WITH FOUR LAYERS OF FIBERGLASS. ALL BRAVO PENETRATIONS, GLUE AND FIBER GLASSING KIITS TO BE SUPPLIED BY COSTCO. OTANK SIINGLE 3/4" CONDUIT TO FIRST GASOLINE TANK. LOOP FROM FIRST TO SECOND TANK, AND ON TO THIRD TANK. PROVIDE SEAL —OFF INI BUILDING & AT TANK. 24 VOLT POWER WIRING FOR SOLENOID VALVES GRAVEL BACKFILL PURSUANT TO MANUFACTURER'S SPECIFICATIONS.. ALL OPEA SUBSTITUTES MUST BE APPROVED BY MANUFACTURER AND OWNER'S FIELD REPRESENTATIVE, OPIPING SHALL BE LAID AND CONTINUOUSLY SUPPORTED ON A 6" COMPACTED PEA GRAVEL BEDDING. PIPING SHALL NOT BE SUPPORTED BY BLOCKS, PLANKS, OR OTHER DEBRIS. ENTRIES TO BE PERPENDICULAR TO CONTAINMENT SUMP. FOLLOW OALL MANUFACTURER'S INSTALLATION INSTRUCTIONS FOR MAXIMUM ANGLE ALLOWANCE. AIDDITIVE PRODUCT PENETRATION TO BE MADE AS CLOSE TO THE TOP OF 1 0 GASOLINE FILL SUMP AS POSSIBLE. IF SITE CONDITIONS PERMIT, PITCH PIPING DOWN TOWARDS ADDITIVE TANK SUMP. BRAVO FRP PENETRATION FITTINGS SHOWN. ALTERNATE FITTINGS MAY 1 1 NOT BE USED. 12 DIROP TUBE CRITICAL DIMENSION: 4" TO 6" MAX. THIS DIMENSION IS CRITICAL AIND MUST BE ADHERED TO. CONTRACTOR WILL BE REQUIRED TO REINSTALL AT OWN EXPENSE OR WILL BE BACK CHARGED FOR EXPENSE TO CORRECT INCONSISTENCIES. 13 SECONDARY CONTAINMENT FOR ALL NEW PRODUCT PIPING m 0 N rn N O E f— O CP N H CD cc co O V N O i Q. N a Q c Q) q) c c Q) cp 00 O O O O O I t vi 0 OD CD 1 6" NPT FITTING to 0 412- (2) 2" NPT (1) 4" NPT FITTING ROLL THE INFLATABLE FITTINGS o °o C O BLADDER TO FIT O 31 NEW MANWAY COVER PLATE THROUGH THE TANK �1 o U o LL MANWAY BUNG TO AIR PUMP CAP EXISTING a ° CAP EXISTING a VENT /VAPOR LINES a ° a a .. in z VENT /VAPOR LINES a ° r J AIR HOSE .s REINSTALL VAPOR RISER & y REMOVE EXISTIING TANK NEW ILL RISER ON NEW r ATTACHED TO RISERS AND P LUG ALL L d' z` '.; } ff�� , Y"tt i NWAY COVER PLATE W � INFLATABLE" BUT 1 BUNG SON ; , LL ��� „ , , Y .r. �' �; ':S n�- " � �i �� �'� �' . V'�." �� v ��r � - "' ;�" 'mot ,}� A 4 � N t . w y F .c."' ;r., #.t.. .:, +i' #' `"F u x'4,5 r•7 mo , L'% ;ter 4,� s . 11 ,� � .�d�BLADDER I � f, ^ Mgr EXISTING TANK; a 6.�3F "`" �:'a'�^• ''3,. b -r'v �}- � _ 3 ^ �'�` . e .,r.v., 3'. 'r ;. ^_ � s�' ;� � � ..'}S, G ,� � ` �, i s �:..4. ,,; +,�z,. , � .p : ..a �". '� a , o- ,�!, a' .•Q. 3 . k Q MANWAY 5} � ��tt a� j % , � y �y E�w ,y�.yp ! �9,u 4j r„p• .Y�' �Fw� -m .s �. �,} � b .. 1 . p.m"� �� � n � ., �r r. a r .,�; - H t. 4 •'.•. . . °:{'`^ , ,. � `fir` '�' £ P w, P' ', � r & Y �,�° � k ,.8 .< 43 :. � .J` > k � 1w. �.k y f... .� : y. 0 OD h. yb ". � 'F.. J2. $ 2 . Ni" .'lS• 4TM r� A e. . �" eu ,4 rim, �� `a� F t � vi.n^r" CjrggJ n 5r F4C r s _ t Y 3 x 's •.1. =+1 •.Jl': 'io% = . "k= 0 RAIN yj t ' s r , s z v v � REMOVE 0 A'.. a 4 a Y i b , d U w4. : * f` 5 , •E '�° w e+ ?r � c ^a w5 b< !r f r z ; i :r azfi 6 y. 1. j ew.Y s rs � r r a t4^ x r 0 k. s T- /' c r�., • �� ,fit Ir ,, T ,ESN s f �r sl is F t ! 6 ,.a y a s ! r t 9 _ x s c, r 7K NITR E BLANK T ITR E BILANK T '\— ITR GEN B N T NEW MANWAY COVER PLATE 31 REMOVE BLADDER AFTER MANWAY INSTALLATION AND PRIOR TO FUEL IN TANK BLADDER FULLY INFLATED TO REMOVE MANWAY BOLTS REINSTALL BALL FLOAT AND EXTRACTOR REINSTALLATION OF RISERS. SEAL TANK ULLAGE SPACE AND COVER A: BLADDER INSTALLATION DETAILS N.T.S. O Q�OF E S - -lNql HA,L P. GRUBB ?, - 8 6/30 'T TF OF d a > z f— f- F- U = N c > c c o 3 U p N co 0 CL CL D 0 C) Q a Cn uj = C5 U I— Z j Z cr- 0 Z N CL J W H x z < Z W LJ C14 Q ON CN C-4 CO ZLx z I I w W N _ _ t\ Q 3�: Lo ' ' Z Lo C14 C14 w % L0 L0 W CN U N uj l7 �` K dtL.c 1 X, r � N E Z OD O s D O i 7 N O N N 0 0 a� �i F-- I LD 00 0 U N O Q Q) Q / Q C C c N 00 O O O O 0 I N L� x 0 a m Li C) 0 V Q LO LC) N O N N F- N O D -o F- I CD 00 O u U N O L 0 Q / C N N C C N / CD 00 O O O O O m ii BUSS: 125A SPACES: 20 DESCRIPTION LOAD BREAKER A B C NOTES LCL EXISTING UTILITY VAULT OR POLE BY POWER COMPANY EXISTING (1) -4" UNDERGROUND PVC CONDUIT (SCHEDULE 80) AS REQUIRED BY POWER COMPANY. EXISTING UTILITY PAD MOUNT TRANSFORMER WITH CONCRETE PAD MINIMUM OF 10' FROM CONTROLLER ENCLOSURE. COPPER GROUND WIRE. EXISTING 3/4" x 10' COPPER CLAD STEEL GROUND ROD EXISTING 2" C, (4} #3/0 C.U. + (1) #4 C.U. E.G. EXISTING 2" C, (4) #3/0 C.U. + (1) #4 E.G. —= EXISTING NEMA 3R, 200A, 175A FUSE SERVICE DISCONNECT SWITCH MOUNTED EXISTING NEMA 3R, ON WALL OF CONTROLLER 200A, METER ENCLOSURE SQ D CAT NO. SOCKET MOUNT ON D324 -NR -B EXTERIOR WALL OF CONTROLLER EXISTING (1) — #4 ENCLOSURE EUSERC COPPER GROUND WIRE COMPLIANCE 65,000 AIC SQ D CAT N0. _EXISTING 3/4" x 10' UTH7213T COPPER CLAD STEEL - - - - - - GROUND WIRE I 1 I EXISTING I 2 -1/2" C, (4) 3/0, (3) #4 EXISTING CONTROLLER I 1 I ENCLOSURE I EXISTING I PETRO POWER CENTER 1 1 POWER INTEGRITY SURG 1 1 MODEL: PPC— COSTC001 GND. 1 1 1 I ( NEUT. SYSTEM ISOLATED I EXISTING (2) #1/0 C.U. + (1) CND. IGND. EXISTING (4) #6 C.U. + (1) #8 #6 E.G� _A_ E.G. I 42 SPC 1 120/208 I LUGS 20 SPC ONLY 12 B PC I 120V 120/208 I I SUB FEED SUB FEED I I DISPENSERS IST I Lc7 Q I I I I I I I PANEL LEFT SIDE (ODD CIRCUITS) LEFT SIDE (ODD CIRCUITS) 0000 —C SURGE 1 MODEM, VEEDER ROOT, D -BOX, CAMERAS, BATCH CONTROLLER (VIA UPS) 1440 30 -1 1440 SUPPRESSION SURGE SUPPRESSION U 3 CANOPY LIGHTS #1 1800 20 -1 20 -2 1800 960 S -1 Y 5 CANOPY LIGHTS #2 1800 20 -1 SWN 0 1800 S -1 Y 7 SPACE 0 FILLER 0 960 P 0W I F- F-~ a ' 9 CANOPY LIGHTS #3 1800 20 -1 SWN 1800 S -1 Y 11 CANOPY LIGHTS #4 1800 20 -1 1800 S -1 Y 13 SPACE 0 FILLER 0 <t cNv I 15 CANOPY LIGHTS #5 1800 20 -1 ~ -' z 1800 S -1 Y 17 SIGNS FASCIA #1 800 20 -1 N cn w Cl� 800 S -2 Y 19 SPACE 0 FILLER 0 � � 21 SIGNS FASCIA #2 800 20 -1 I a CL 800 S -2 Y 23 QUAD BOX RECEPTACLE 360 20 -1 360 IG e�lr l I ��'� 25 SPACE 0 FILLER 0 114 J14 J14 J14 27 CANOPY LIGHTS #6 1800 20 -1 1800 S -1 Y 29 CANOPY LIGHTS #7 1800 20 -1 ° 1800 S -1 Y 31 SPARE 1000 20 -1 1000 u �L,_J� Y 33 SPARE 1000 20 -1 1000 Y 35 SPARE 1000 20 -1 v 1000 Q Y 37 SPARE 1000 20 -1 1000 Li z Y 39 FUTURE ELECTRONICS 1000 20 -1 1000 IG 41 QUAD BOX RECEPTACLE 864 20 -1 Li CONTROLS 864 IG RIGHT SIDE (EVEN CIRCUITS ) N 2 SPACE 0 FILLER 0 4 FUTURE ELECTRONICS 720 20 -1 720 L0 6 FUTURE ELECTRONICS 720 20 -1 x 720 x 8 SPARE 1300 20 -1 1300 Y 10 SPARE 1350 20 -1 cwn 1350 12 KIOSK LIGHTS 720 20 -1 z Li u� 720 Y 14 SPACE 0 FILLER 0 ISOLATION RELAYS o 16 KIOSK AC / HEAT 2500 30 -2 2500 18 KIOSK AC / HEAT 2500 30 -2 2500 20 SUB FEED TO PANEL B 3840 50 -3 3840 2" X 13" WIREWAY 22 SUB FEED TO PANEL B 3840 50 -3 3840 24 SUB FEED TO PANEL B 3240 50 -3 3240 26 SHUNT TRIP 0 SHUNT 0 DIN FIELD WIRING 28 LIGHTS, TIMER POWER 180 15 -1 N 180 TERMINALS 30 SPACE 0 FILLER E 0 32 SPACE 0 FILLER 0 34 PACE SPACE 0 FILLER 0 36 SHUNT POWER TRIP 180 15 -1 180 38 SUB FEED TO PANEL C 9600 125 -2 9600 40 DISPENSERS— (PHASE A ONLY ) 1 O 125 -2 0 42 SHUNT TRIP 1 0 SHUNT 0 NOTE: BATCH CONTROLLER AT CIRCUIT A -1 SHALL BE ROUTED THRU THE EXISTING EMERGENCY SHUT OFF SYSTEM. THERE IS ADDITIONAL LOAD FROM SUB —PANEL "B ". TOTAL VA 18180 18590 15784 10350 7920 2588 1980 21178 17764 176.5 148.0 LCL 2000 PLUS 25% 500 TOTAL VA 18680 AMP PER P 155.7 PANEL LOAD 159.9 PANEL B FE PETRO IST VOLTAGE: 120/208 VOLT -30, 4 -WIRE MAIN BRKR: FEED FROM -A- BREAKER RATED: 10,000 A.I.C. BUSS: 125A SPACES: 12 CIRCUIT # DESCRIPTION LOAD BREAKER PHASE NOTES LCL A B c LEFT SIDE (ODD CIRCUITS) 1 FE PETRO IST #1 960 20 -3 960 3 FE PETRO IST #1 960 20 -3 960 5 FE PETRO IST #1 960 20 -3 960 T !7D DCTDn ICT 1L'> nl^n I On— -4 nGn BUSS: 125A SPACES: 20 TVSS GROUND CIRCUIT # DESCRIPTION LOAD BREAKER PHASE NOTES LCL I I PANEL A LEFT SIDE (ODD CIRCUITS) 0000 —C SURGE 000 1 SWITCHED NEUTRAL 0 SWN SUPPRESSION SURGE SUPPRESSION 0000 3 MODULES 20 -2 IG 960 P (3) (10) 5 SWITCHED NEUTRAL 0 SWN 0 IG 0 e 7 DISPENSER #2 960 1" X 6.5" WIREWAY 960 P 0W I F- F-~ a ' 9 P W R L U G 0 SWN 0 1" X 13" WIREWAY 1" X 11" WIREWAY V) U) L/) C� <t cNv I F- M F- v o ) ~ -' z w N N N cn w Cl� N N N N I v 0 � � � I a CL 1" X 6.5" WIREWAY z �yT O d U Q O e�lr l I ��'� e�4:" I'1 O I15 I1 114 J14 J14 J14 Q PANEL ° __j -B- u �L,_J� c� 1" X 11" WIREWAY � v Q Q w Li z LIGHT LLJ Li Li CONTROLS „ 1 X 7.75 WIREWAY N DISPENSER POWER Ln u ISOLATION RELAY'S � o Lo L0 (4) N 0 x x x cwn 1" X 7.75" WIREWAY z Li u� DISPENSER POWER ISOLATION RELAYS o (4) P N E 2" X 13" WIREWAY L A LIGHT CONTROL DIN FIELD WIRING PANEL N TERMINALS TERMINALS —A— E U BUSS: 125A SPACES: 20 0000 CIRCUIT # DESCRIPTION LOAD BREAKER PHASE NOTES LCL I I A A LEFT SIDE (ODD CIRCUITS) 0000 0o 000 1 SWITCHED NEUTRAL 0 SWN 0 0000 3 DISPENSER #1 960 20 -2 IG 960 P IG IG 5 SWITCHED NEUTRAL 0 SWN 0 IG 0 e 7 DISPENSER #2 960 20 -2 960 P 0W I F- F-~ a ' 9 SWITCHED NEUTRAL 0 SWN 0 I 1 m 0 N O N E H N w I Q0 co 00 O v a� 0 L Q a� Q a� c N N C C 00 O O O O O II v i� 0000 0000 � I � 4 � z 0000 0000 0o 000 Qo 0000 0000 000 IG IG IG IG IG IG IG IG IG IG IG m 0 N O N E H N w I Q0 co 00 O v a� 0 L Q a� Q a� c N N C C 00 O O O O O II v i� 0000 0000 � I � 4 � z 0o Qo W M I 0 e 0 e LLJ Uw 0000 0W I F- F-~ a ' � V) L/) cNv I F- M F- v o ) N N N N N N N N I v 0 � � � I a CL Syr ya�� �yT O d U Q O e�lr l I ��'� e�4:" I'1 119 I15 I1 114 J14 J14 J14 m 0 N O N E H N w I Q0 co 00 O v a� 0 L Q a� Q a� c N N C C 00 O O O O O II v i� HELP TROUBLE— SHOOTING WITH THE IN -TANK SETUP N L MODULE TYPE: NOT USED POSITION RECORD: LOCATIONS. T- 4:ADDITIVE o ® o 2 N PRODUCT CODE ADDITIVE 3 4 8 AT THE END OF ALL THE GASOLINE THERMAL COEFF .000700 SPARE 15 TANK AND DISPENSER SENSORS, SPARE TANK DIAMETER 2 47.00 r Root Console PROGRAM THE ADDITIVE SENSORS 8 TANK PROFILE 7 LINEAR NOTE: THE ONLY WORK DONE 1 INCLUDING THE ADDITIVE TANK FULL VOL POSITION RECORD: 1200 ON THE VEEDER ROOT SYSTEM ANNULAR, TANK SUMP, AND SPARE METER DATA 2 NO DISPENSER SUMP, IN THAT ORDER. 3 15 FLOAT SIZE 4.0 IN. T 4 LOW PRODUCT ALARM MAX OR LABEL VOL INTERSTITUAL /LIQUID SENSOR 1200 5 13 OVERFILL LIMIT 6 90% LIQUID SENSOR ALMS F- t 2 3 4 5 6-:1— 7 S 1 t —I + —I + 1' �+ �+ "F —i + —1 MAXIMUM SENSOR RATING INTERFACE MODULE, ADDITIVE 1080 L 18 ADDITIVE SENSOR HIGH PRODUCT OVTPUT 95% L 18 SPARE SENSOR OUT ALARM 4 SPARE ♦ , • ♦ • • • , a • • • • e • 1140 L 18 14 SHORT ALARM DELIVERY LIMIT 6 9% ISO SENSORS ADDITIVE HIGH LIQUID ALARM 5 , THE ADDITIVE TURBINE CONTROLLER 110 L 18 ADDITIVE LOW LIQUID ALARM LOW PRODUCT 7 60 4 7 -INPUT SMART SENSOR INTERFACE MODULE /FILL /ANNULAR SENSORS LEAK ALARM LIMIT 1 REG. UNL A ANNULAR 8 2 1 REG. UNLEADED #1 �-1 2 3 4 5 6 I' I T I T I T T SUDDEN LOSS LIMIT 2 REG. UNLEADED #2 40 3 PREM. UNLEADED #1 4 REG. UNL B ANNULAR PRESSURE TANK TILT OUTPUT RATING 15 voc 0.00 POSITION RECORD: SPARE 1 CONT, ENCI -SR. VR REMOTE ALARM PROBE OFFSET 2 ADDITIVE TURBINE 0.00 3 SPARE NEW 13 4 SPARE SIPHON MANIFOLED TANKS 5 OOOOOOOOpj00P PLLD 8 SPARE GROUND NEW HE T #: NONE TURBINE MANIFOLED TANKS PRESSURE LINE LEAK INTERFACE MODULE SUMPS T #: NONE -{- +2� - +3T 4� +5-- +6� +7� +5� LEAK MIN PERIODIC 0% SENSOR — I OUTPUT 1s voc 0 SPARE0 LEAK MIN ANNUAL O • O 0 • • 0% 2 q 0 ADDITIVE PERIODIC TEST TYPE STANDARD SENSORS ANNUAL TEST FAIL ALARM DISABLED INTERSTITIAL SENSOR INTERFACE MODULE PERIODIC TEST FAIL ALARM DISABLED Ft 2 3 4 5 6 7 3 I t —I + —I + —I t —I + + -1 + —1 + —1 GROSS TEST FAIL: ALARM DISABLED SPARE• ANN TEST AVERAGING: OFF ,5 voc 15 AMP 11 PER TEST AVERAGING: OFF 00 00 000 0 0000 0 (2) (Del TANK SUMPS NOTE ON ADDITIVE LIQUID SENSOR TANK TEST NOTIFY OFF & DISPENSER ALARMS WHEN PROGRAMMING THE TNK TST SPHON BREAK: OFF INTERSTITIAL SENSOR INTERFACE MODULE VEEDER —ROOT LIQUID SENSORS FOR DELIVERY DELAY 1 MIN 1 2 3 4 5_1+6_4+7A+11_1 I + —I + —I + -I + —I + THE ADDITIVE SYSTEM, PLEASE STICK OFFSET 0.00 SENSOR � NUMBER THEM AT THE END OF THE • o ♦ • a ♦ m • o 0 0 0 • • • • PO -PUMP OUTPUT CONTROL EXISTING SENSOR LIST. THIS WILL 15 AAUP 10 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 10 F_R EUY RATacs FIX2M A 6CBLIACFS HELP TROUBLE— SHOOTING WITH THE OUTPUT RELAY N L MODULE TYPE: NOT USED POSITION RECORD: LOCATIONS. 1 o ® o 2 N R 7 ADDITIVE SHUTDOWN TYPE: 4 8 AT THE END OF ALL THE GASOLINE MODULE TYPE: NOT USED STANDARD NORMALLY SPARE 15 TANK AND DISPENSER SENSORS, SPARE 5 2 16 r Root Console PROGRAM THE ADDITIVE SENSORS 8 3 7 8 NOTE: THE ONLY WORK DONE 1 INCLUDING THE ADDITIVE TANK MODULE TYPE: NOT USED POSITION RECORD: 14 ON THE VEEDER ROOT SYSTEM ANNULAR, TANK SUMP, AND SPARE 6 DISPENSER 2 SPARE DISPENSER SUMP, IN THAT ORDER. 3 15 8AMB. COND BLANK — DONOT USE 4 7 T 4 LOW PRODUCT ALARM POSITION RECORD: INTERSTITUAL /LIQUID SENSOR NOTE ON ADDITIVE LIQUID SENSOR 5 13 2 6 ALARMS: LIQUID SENSOR ALMS F- t 2 3 4 5 6-:1— 7 S 1 t —I + —I + 1' �+ �+ "F —i + —1 MAXIMUM SENSOR RATING INTERFACE MODULE, ADDITIVE THE ALARM NUMBERS SHOWN HERE L 18 ADDITIVE SENSOR OVTPUT REFLECT A PARTICULAR LOCATION L 18 SPARE SENSOR OUT ALARM 4 SPARE ♦ , • ♦ • • • , a • • • • e • G.2 A,aP L 18 14 SHORT ALARM DISPENSER SENSORS 6 0000000 0 0000 00 0 01 ISO SENSORS ADDITIVE HIGH LIQUID ALARM 5 , THE ADDITIVE TURBINE CONTROLLER CONTRACTOR TO FIELD DETERMINE L 18 ADDITIVE LOW LIQUID ALARM 3 7 THE NEXT AVAILABLE LIQUID SENSOR 4 7 -INPUT SMART SENSOR INTERFACE MODULE /FILL /ANNULAR SENSORS MODULE TYPE: PLLD CONTROLLER MODULE 1 REG. UNL A ANNULAR POSITION RECORD: 2 1 REG. UNLEADED #1 �-1 2 3 4 5 6 I' I T I T I T T MAXIMUM SENSOR 2 REG. UNLEADED #2 7 PREM. UNL ANNULAR 3 PREM. UNLEADED #1 4 REG. UNL B ANNULAR PRESSURE 1� I I - OUTPUT RATING 15 voc POSITION RECORD: SPARE 1 CONT, ENCI -SR. VR REMOTE ALARM xM1T 2 ADDITIVE TURBINE 15 AMP 3 SPARE NEW 13 4 SPARE GROUND 919 5 OOOOOOOOpj00P PLLD 8 SPARE GROUND NEW HE TURBINE PRESSURE LINE LEAK INTERFACE MODULE SUMPS -{- +2� - +3T 4� +5-- +6� +7� +5� MAXIMUM SENSOR RATING SENSOR — I OUTPUT 1s voc SPARE0 O • O 0 • • 5 AMP 2 q 0 0 ADDITIVE SENSORS INTERSTITIAL SENSOR INTERFACE MODULE Ft 2 3 4 5 6 7 3 I t —I + —I + —I t —I + + -1 + —1 + —1 MAXIMUM SENSOR OUTPUT RATING SPARE• SENSOR- • • • • • • o • a o o -1- • 0 ,5 voc 15 AMP 11 3 00 00 000 0 0000 0 (2) (Del TANK SUMPS & DISPENSER INTERSTITIAL SENSOR INTERFACE MODULE SENSORS I - UNL, Al 2- UNL. 2 3- PREM. PI - PUMP INPUT SIGNAL PI PR LIP PI PR LIP PI PR LIP PR - PUMP RETURN (NEUTRAL) 1 2 3 4 5_1+6_4+7A+11_1 I + —I + —I + -I + —I + MAXIMUM SENSOR OUTPUT RATING LI - LINE POWER INPUT SENSOR � ,s voc • o ♦ • a ♦ m • o 0 0 0 • • • • PO -PUMP OUTPUT CONTROL • • o m o • o o • , o • s o 0 0 15 AAUP 10 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 10 F_R EUY RATacs FIX2M A 6CBLIACFS 2 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TANK SUMPS & ANNULAR zi °unxAC SENSORS PRESSURE LINE LEAK CONTROLLER MODULE INTERSTITIAL SENSOR INTERFACE MODULE 4 -RELAY OUTPUT MODULE PROBE ---=- I —' PROBE - -� �- RELAY TO EXTERNAL DEVICE NCt NO C NC NO C NC3 NO C NC NO C RELAY RATINGS �- t 2 3 4 I "L' �'}' �+ _ + 'I MAXIMUM SENSOR OUTPUT RATING 15 voc o • 101 e • s • • • m FROM C CONTACTS 120 VAC. 2A MAX OR • a • o15 AMP 0� 0 0 0 0 0 0 0 0 0 Qj za voc, zA MAx Q) TANK LEVEL PROBE INTERFACE MODULE GAUGES ® ® ® ® ® ® HELP TROUBLE— SHOOTING WITH THE OUTPUT RELAY SETUP MODULE TYPE: NOT USED POSITION RECORD: LOCATIONS. 1 5 2 6 R 7 ADDITIVE SHUTDOWN TYPE: 4 8 AT THE END OF ALL THE GASOLINE MODULE TYPE: NOT USED STANDARD NORMALLY POSITION RECORD: 15 TANK AND DISPENSER SENSORS, CLOSED 5 2 6 r Root Console PROGRAM THE ADDITIVE SENSORS 7 3 7 8 NOTE: THE ONLY WORK DONE 1 INCLUDING THE ADDITIVE TANK MODULE TYPE: NOT USED POSITION RECORD: 14 ON THE VEEDER ROOT SYSTEM ANNULAR, TANK SUMP, AND IN —TANK ALARMS 6 DISPENSER 2 IS TO INSTALL /ADD THE DISPENSER SUMP, IN THAT ORDER. 3 7 8AMB. COND BLANK — DONOT USE 4 ADDITIONAL EIGHT INPUT T 4 LOW PRODUCT ALARM POSITION RECORD: INTERSTITUAL /LIQUID SENSOR NOTE ON ADDITIVE LIQUID SENSOR 5 13 2 6 ALARMS: LIQUID SENSOR ALMS 4 INTERFACE MODULE, ADDITIVE THE ALARM NUMBERS SHOWN HERE L 18 ADDITIVE FUEL ALARM 2 ADD. TRANSITION SUMP ANNULAR SENSOR, ADDITIVE REFLECT A PARTICULAR LOCATION L 18 ADDITIVE SENSOR OUT ALARM 4 SPARE LEVEL GAUGE PROBE, ADDITIVE PRODUCT SENSOR, ADDITIVE WHERE THE NEXT LIQUID SENSOR L 18 ADDITIVE SHORT ALARM DISPENSER SENSORS VENT SENSOR AND WIRE IN ALARMS TO BE USED IS 18. L 18 ADDITIVE HIGH LIQUID ALARM 5 , THE ADDITIVE TURBINE CONTROLLER CONTRACTOR TO FIELD DETERMINE L 18 ADDITIVE LOW LIQUID ALARM 3 7 THE NEXT AVAILABLE LIQUID SENSOR 4 8 /FILL /ANNULAR SENSORS MODULE TYPE: PLLD CONTROLLER MODULE 1 REG. UNL A ANNULAR POWER AREA GROUND Lei I GE MODULE TYPE: NOT USED POSITION RECORD: 16 1 5 2 6 3 7 4 8 MODULE TYPE: NOT USED POSITION RECORD: 15 1 1 5 2 6 2 6 7 3 7 8 4 8 MODULE TYPE: NOT USED POSITION RECORD: 14 5 DISPENSER 2 011/12 2 DISPENSER 34 6 DISPENSER 2 6 7 ISD PRESSURE SENSOR 3 7 8AMB. COND BLANK — DONOT USE 4 8 MODULE TYPE: NOT USED POSITION RECORD: 5 SPARE 1 5 13 2 6 3 7 4 8 POSITION RECORD: ADDITIVE SENSORS MODULE TYPE: NOT USED 1 ADDITIVE ANNULAR POSITION RECORD: 2 ADD. TRANSITION SUMP 5 12 3 SPARE 2 6 4 SPARE 3 7 MODULE TYPE: INTERSTITIAL SENSOR INTERFACE 4 8 DISPENSER SENSORS MODULE TYPE: NOT USED 1 PREM. UNL TURB POSITION RECORD: 3 1 5 3 DISPENSER 3/4 2 6 4 DISPENSER 5/ 3 7 MODULE TYPE: INTERSTITIAL SENSOR INTERFACE 4 8 /FILL /ANNULAR SENSORS MODULE TYPE: PLLD CONTROLLER MODULE 1 REG. UNL A ANNULAR POSITION RECORD: 2 1 REG. UNLEADED #1 10 2 REG. UNLEADED #2 7 PREM. UNL ANNULAR 3 PREM. UNLEADED #1 4 REG. UNL B ANNULAR 4 SPARE MODULE TYPE: 4 —RELAY OUTPUT MODULE POSITION RECORD: 1 CONT, ENCI -SR. VR REMOTE ALARM 9 2 ADDITIVE TURBINE 1 3 SPARE NEW 6 SPARE 4 SPARE GROUND 919 INTRINSICALLY -SAFE AREA GROUND 99 MODULE TYPE: NOT USED POSITION RECORD: 1 5 2 6 3 7 4 8 MODULE TYPE: NOT USED POSITION RECORD: 7 1 5 2 6 3 7 4 8 MODULE TYPE: SMART SENSORS 7 —SLOT POSITION RECORD: ISD VAPOR FLOW SENSORS 1 DISPENSER 1/2 5 DISPENSER 2 011/12 2 DISPENSER 34 6 DISPENSER 3 DISPENSER 5/6 7 ISD PRESSURE SENSOR 4 DISPENSER 7/8 8AMB. COND BLANK — DONOT USE MODULE TYPE: PLLD INTERFACE MODULE POSITION RECORD: TURBINE PLLD 1 REG. UNLEADED #1 5 SPARE 5 2 REG. UNLEADED #2 6 SPARE 3 PREM. UNLEADED #1 7 SPARE 4 SPARE 8 SPARE MODULE TYPE INTERSTITIAL SENSOR INTERFACE POSITION RECORD: ADDITIVE SENSORS 4 1 ADDITIVE ANNULAR 5 SPARE 2 ADD. TRANSITION SUMP 6 SPARE 3 SPARE 7 SPARE 4 SPARE 8 SPARE MODULE TYPE: INTERSTITIAL SENSOR INTERFACE POSITION RECORD: TURBINE DISPENSER SENSORS 1 PREM. UNL TURB 5 DISPENSER 7/8 3 2 DISPENSER 1/2 6 DISPENSER 9/10 3 DISPENSER 3/4 7 DISPENSER 11/12 4 DISPENSER 5/ 8 SPARE MODULE TYPE: INTERSTITIAL SENSOR INTERFACE POSITION RECORD: TURBINE /FILL /ANNULAR SENSORS 1 REG. UNL A ANNULAR 5 REG. UNL B FILL 2 2 REG. UNL A FILL 6 REG. UNL B TURB 3 REG. UNL A TURB 7 PREM. UNL ANNULAR 4 REG. UNL B ANNULAR 8 PREM. UNL FILL MODULE TYPE: PROBE INTERFACE MODULE POSITION RECORD: TANK LEVEL GAUGES 1 REG. UNLEADED A 5 SPARE 1 2 REG. UNLEADED B 6 SPARE 3 PREM. UNLEADED 7 SPARE 4 ADDITIVE 8 SPARE GROUND NEW HE L x 0 J Q CI] W F- U a _N U Q N O N U E 1— G) O D 3 N W I Q0 co 00 O V G) O i Q 4) a Q C G) Q) C c C Q) / Q0 Lfl GD O v7 O O O O W N a 1 1 I 1 A E -4 IH ID LH AD JH JD 'rr% -rL� r :JH OD VH VD /H /D OH OD r- - 1 1 1 1 1 4 J I c 1 1 1 1 1 1 1 1 1 1 1 1 I 1 I 1 1 1 1 1 1 I 1 1 1 1 1 1 1 1 1 1 1 q 1 1 1 1 I 1 E INUMV 22 a Eli rdws z j 12 13 14 15 ® ® ®® 16 17 18 19 ®® 20 21 22 ® ®® I W � m J CABLE 88760 �� # ,err„ rr,� i LVYV METER INUMV 22 a o Q m L z 11 ®8 ® 12 13 14 15 ® ® ®® 16 17 18 19 ®® • • yr v.. yr Optional Expansion o M-1 o o from Other Board y 'DD' 'DD's p C< s E -4 o Q 1 2 3 4 ri Optional Expansion to Other Board 6*.L rrr rrrr i.'T rrrr rt ®r I�, tom._ 1 t t N 1 Ea `4)1�1C' �D® 0 V Q v J N #,iM w 0 N 0 N E F— 0 w I co CD co O U 0 Q v a c Q) Sz Sz Q) i 0 0 00 0 0 0 0 0 6 I o Q m L 0 ® ®® 11 ®8 ® 12 13 14 15 ® ® ®® 16 17 18 19 ®® 20 21 22 ® ®® I W � m J CABLE 88760 �� # ,err„ rr,� i LVYV METER J � Q o cn JJ J Q o > cn J�9 J a o % cn Jy LUVV VOLTAGE 1'�n�� I IpC ,.,,�,.,� �!. 0 N 0 N E F— 0 w I co CD co O U 0 Q v a c Q) Sz Sz Q) i 0 0 00 0 0 0 0 0 6 I LEFT WALL WINDOW / ORIENTATION THIS SIDE 6"x6"x39" WIREWAY W/ -\ DIVIDERS MEDIA FILTER UPS QUAD BOX RECEPT. FIBER /PHONE U_ 15 0 0 TERMINATION A-1 0 0 Box TT— CD TO EXISTING TO EXISTING IICOSTCO STORE DISPENSER I I ISLANDS II LEFT WALL ELEVA110N SCALE: NTS DEDICATED DUPLEX MAG RECEPTACLE WIRED TO ALLIED EMERGENCY SHUTDOWN AND] SWITCHES BOX GILBARCO A -19 + D -BOX U -15 A -1 MAG MAG MAG STP VFC VFC VFC CBS D -9 - A -19 + A -1 96 UNL UNL PREM ADD A B C D L- - - -3 L L _LL'1 I rTP )CBS) d m 0 °�IO o ho of -9 SIDE zw �j SIDE NO TO EXISTING TANKS PUMP SEE CRIND SIDE zw �j SIDE A -9 - U- 15 D -9 - A -19 + A -1 B -19 + PROTECTION & DATA DISCONNEC 98 B Q Tlopq# A • w V)ry �0 w z CK wa 5a GSM GSM ' 1 A -1 I I 0 0 0 0 I O 0 0 0 o z 22 3 In 3 6" 6 "x 6" I�EWAY I ( 25 I w SEAL FF l (TYP.) i I( 1 I I I EQUIPMENIT INSIDE CONTROLLER ENCLOSURE (TYP) 1A V TO EXISTING DISPENSER ISLANDS r ALLIED SEE NOTE #4 �w 1 zw �j j s X' j ALIGN HV /I.S. PARTITION IN (E) (WIREWAY I I °pBAoX° CONDUIT PURPOSE INSIDE • VEEDER R MODULE OT �® CONTROLLER L- - - -3 L L _LL'1 I rTP )CBS) MAG r -T rM,GI )VFC) IVFCI )VFC) ENCLOSURE (TYP) F- �r -1 VluDAArTAN� 'ADD' 'PREJ 'UNL' 'UNL) # LS'^1 LS "' ba'70a 1 LDJ LCJ LBJ LAJ SIZE 7U L_j 14 ' © F- - - - - - - 7a - -�- - __- - - - --� ) F,BER /PHONE I L - - .- .-. - - - J (5) #12 THWN, (2) #12 GND. - J - _J - J TERMINATION PANEL ' I ® I A -1 6 "x6 "x18" HV o QO WIREWAY Box ] 12 "x6" NEMA 3R U -14 I.S. I C ] I WIREWAY. ® 1" DISPENSER POWER I I L- - - - - -J ® 3/4" ESO /VEEDER ROOT ALARM ® ENCLOSURE SEALOFF "- ` N Ld 0 z w w cn F- U w z z 0 U V) 0 z Q PETRO POWER CENTER POWER INTEGRITY SEE NOTE #5 (CONDUIT LOCATION UNDER POWERBOX CENTER CONTRACTOR DISCRETION. ARRANGE TO MINIMIZE CROSSING OF CONDUCTORS) CONDUIT ENCLOSURE UNDER CABINET BY G.C. IF REQUIRED -- - LT TO EXISTING DISPENSER ISLANDS TO EXISTING DISPENSER ISLANDS C-� RIGHT WALL ELEVA110N *4 SCALE: NTS i SEE NOTE #4 �w 1 zw �j )Zw ALIGN HV /I.S. PARTITION IN CONDUIT FILL WIREWAY WITH HV /I.S. CONDUIT PURPOSE DIVISION ON VEEDER ROOT • VEEDER R MODULE OT �® CONDUIT FILL • • • • • UA 11 CONDUIT PURPOSE CONDUIT FILL Ia SIZE # U -14 # PMT # A -1 ). SIZE 7U 2" 14 ' © 1" I ADDITIVE 1 all- CONTROLLER (5) #12 THWN, (2) #12 GND. I 3/4" PANEL ' I ® I A -1 6 "x6 "x18" HV o QO WIREWAY ' L (2) #12 THWN, (1) #12 GND. U -14 I.S. SECURITY TO WAREHOUSE EDP ROOM Y OD V V JY JJ GG I J4t14 b)4 '�� 68 071 65 32 40 46 37 75 < 7a �A�A� > w z1 ° 0 vi F Li 'TO EXISTING DISPENSER ' ISLANDS TO EXISTING TANKS NTS EQUIPMENT INSIDE CONTROLLER ENCLOSURE (TYP) VEIIER 11OT -1 L-r - -o-J C 18"x6' NEMA 3R (- - - - - -- WIREWAY. (E) WIREWAY INSIDE ' CONTROLLER L ENCLOSURE (TYP) ' SEALOFF (TYP.) SEALOFF ------------------------------------- - - - --� 0 0 ENCLOSURE DROP CEILING LOW VOLTAGE WIRING DISCONNECT 1 -14 B -20 A -1 00 00 �- 6 "x6 "x42" WIREWAY FIELD CONFIGURE CONDUIT TERMINATIONS AT WIREWAY TO ALLOW SEPARATION OF HIGH VOLTAGE AND LOW VOLTAGE WIRING WITH BARRIER AS NEEDED (1) 3/4" C (3) #12 &- (1) #12 GND (1) 3/4" C (2) #12 &- (1) #12 GND FILL END FINISHED FLOOR o W o ), J� �w 1 zw �j )Zw <z SCALE: NTS i \ I \ cF I °o I \� I \ I / I � J � I / l � AIR CONDITIONER A -33,35 LIGHT SWITCH PRE -WIRED A -12 PRE -WIRED A/C RECEPTACLE SHEET NOTES 1. ROUTE CONDUIT TO EQUIPMENT AS INDICATED ON SHEET E -2 & E -3. 2. ROUTE CONDUIT AND CONDUCTORS TO EXTERIOR OF CONTROLLER ENCLOSURE WALL AS INDICATED ON THIS SHEET. 3. FUNCTIONS OF THE CONTINUOUS MONITORING: - MONITORING OF ALL ANNULAR SPACES. - MONITORING OF ALL PRODUCT PIPING SUMPS. - PROVIDE .1 GPH PRESSURE LINE LEAK DETECTION (PLLD) OF GASOLINE PRODUCT LINES. - PROVIDE CONTINUOUS TANK LEVEL MONITORING. - DISPENSER SUMP MONITORING. THE CONTINUOUS MONITORING DEVICE SHALL PROVIDE POSITIVE SHUTDOWN OF TURBINES AND DISPENSERS AUTOMATICALLY IN THE EVENT OF A LIQUID RELEASE AND MANUALLY THROUGH THE ESO SWITCH LOCATED ON THE CONTROLLER ENCLOSURE AND REMOTE ESO SWITCH AS INDICATED ON SITE PLAN. 4. ALL WIRES ENTERING CONTROL PANELS, MAIN PANELS, AND SUB PANELS SHALL BE MARKED WITH PHASE TAPE CODING AS FOLLOWS: "A" PHASE = BLACK "B" PHASE = RED "C" PHASE = BLUE CONTRACTOR TO LABEL TURBINES AND CONTROLLERS AS TO WHICH SIDE OF THE STATION THEY SERVE. GREEN CONTROLLER LIGHTS X3/4" C, (1) BELDEN #88760 TURBINE END VENT STACKS ARE TO GO OUT WHEN TURBINES ARE OFF OR LOSE POWER. SEAL -OFFS ON EACH END OF CONDUIT 5. WALL MOUNTED EQUIPMENT LOCATIONS ARE FIXED AS SHOWN REGARDLESS OF CONTROLLER ORIENTATION. G.C. SHALL NOT MOUNT EQUIPMENT OTHER THAT WHAT IS SHOWN. WIRING YV LEGEND 6. ALL CONDUIT ENTERING UNDERGROUND TANK SUMPS SHALL BE PVC POWER CONDUIT COATED RIGID METAL "ROBROY" CONDUIT. NO EXCEPTIONS. POWER & DATA CONDUIT 7. ALL CONDUIT BETWEEN WIREWAYS AND ELECTRICAL DEVICES CAMERA /COMM. CONDUIT SHALL BE EMT OR RIGID GALVANIZED STEEL. NO EXCEPTIONS. - - -------------- INTRINSICALLY SAFE CONDUIT ® INDICATES ITEM ON MATERIALS LIST SEE DWG. T -4 CONDUIT SCHEDULE CONDUIT CONDUIT PURPOSE CONDUIT FILL CONDUIT CONDUIT CONDUIT FILL CONDUIT CONDUIT PURPOSE CONDUIT FILL • CONDUIT CONDUIT PURPOSE CONDUIT FILL • • • • • CONDUIT CONDUIT PURPOSE CONDUIT FILL # SIZE # SIZE # SIZE # SIZE # SIZE 7U 2" PHONE SERVICE TO EDP ROOM (2) 25 PAIR PHONE WIRE, (1) #12 GND. © 1" DISPENSER POWER 5 #12 THWN; 4 #14, (2) #14 TWISTED PAIR & 1 #12 GND. all- LOOP TO RIGHT WALL E.S.O. AND V.R. (5) #12 THWN, (2) #12 GND. ® 3/4" CAMERA POWER SUPPLY IN 18xl8x6 NEMA 3R ENCLOSURE (2) #12 THWN (1) #12 GND. ® 3/4" DISPENSER HOOKS - UNLEADED A (2) #12 THWN, (1) #12 GND. 20 2" SECURITY TO WAREHOUSE EDP ROOM (2) 18 -2, (2) 18 -6 ® 1" DISPENSER POWER 5 #12 THWN; 4#14,(2) #14 TWISTED PAIR & 1 #12 GND. ® 3/4" ESO /VEEDER ROOT ALARM ® ENCLOSURE (5) #12 THWN, (1) #12 GND. EO 2" DATA LOOP 70 FIBER /PHONE BOARD AS REQUIRED CURRENT COSTCO I.S. SETUP 0 3/4" DISPENSER HOOKS - UNLEADED 13 (2) #12 THWN, (1) #12 GND. 1" EDP TO BURGLAR PANEL @ ENTRY AREA (2) 18 -2, (2) 18 -6 0 1" DISPENSER POWER 5 #12 TFNIN; 4 #14, (2) #14 TWISTED PAIR & 1#'12 CND. (D 1" SPARE TO EDP ROOM 25# PULL ROPE [J�1 (8) 1" DISPENSER ETHERNET COMMUNICATION CABLING 25# PULL CORD ® 3/4" DISPENSER HOOKS - PREMIUM C (2) #12 THWN, (1) #12 GND. ® 1" FIBER OPTIC - CONTROLLER TO CORNING 012K8F- 31130- 29 OR EQUAL 0 (NOT USED) 1" PREMIUM TANK #3 MONITORING DEVICES (5) BELDEN CABLE #88760 (1) #12 GND. ® (NOT USED} ® 3/4" ADDITIVE HOOK FROM CONTROL PANEL (2) #14 THWN, (1) #14 GND. Q 3/4" LOOP TO 911 PHONE (2 PR) PHONE CABLE, (1) #12 GND. �� (NOT USED) ® 1" UNLEADED TANK #2 MONITORING DEVICES (5) BELDEN CABLE #88760 (1) #12 GND. ® (NOT USED) 69 1" FUTURE EQUIPMENT 25# PULL CORD © 1" UNLEADED TANK #1 TURBINE POWER (3) #12 THWN, (1) #12 GND. fa 1" LOOP TO VEEDER ROOT 25# PULL ROPE a 1 1" UNLEADED TANK #1 MONITORING DEVICES (5) BELDEN CABLE #88760 (1) #12 GND. ® (NOT USED) QD 3/4" FUTURE PHONE LINE TO VEEDER ROOT PANEL 25# PULL ROPE 7� (NOT USED) (2) 2 "'' DISPENSER WIRING - LOOPS TO POWER CENTER 2 12 THWN + 1 #112GGND.((RECEPTACLEN CONDUITS 3/4 °' DISPENSER SENSOR (1) BELDEN CABLE #88760 (1) #12 GND. 3/4" ARID PERMEATOR LOOP FOR POWER (3) #12 THWN & (2) #12 GIRD. ® (NOT USED) ® 1" UNLEADED TANK #2 TURBINE POWER (3) #12 THWN, (1) #12 GND. 2" LOOP TO DISCONNECT (4) 3/0, (4) #4 GND. �( 3/4" DISPENSER SENSOR (1) BELDEN CABLE #88760 (1) #12 GND. ® 1-1/4" CAMERA FEEDS TO CANOPY (12) AWG BELDEN 7928A (%/Oj1 RESSTANTR #FILL BY CAMERA CONTRACTOR (NOT USED) 9Q (NOT USED) 3/4" FUTURE AIR /WATER REEL 25# PULL ROPE ® 3/4" DISPENSER SENSOR (1) BELDEN CABLE #88760 (1) #12 GND. ® 3/4" POWER LOOP TO PHONE PANEL (2) #12 THWN, (2) #12 GND. ® (NOT USED) a 1" PREMIUM TANK #3 TURBINE POWER (3) #12 THWN, (1) #12 GND.* ® 3/4 ".FASCIA /SECURITY LIGHTS - A -17, A -21 (3} #10 THWN, (1) #10 GND. ® 3/4" DISPENSER SENSOR (1} BELDEN CABLE #88760 (1) #12 GND. ® (NOT USED) ® 3/4" ADDITIVE TURBINE POWER (2) #10 THWN, (1) #tOGND. 11 1" PREMIUM TANK #4 TURBINE POWER (SPARE) 25# PULL ROPE © 1" CANOPY LIGHTS - A -3, A -5, A -9, A -]1, A -15 (8} #10 THWN, (1) #10 GND. ® 3/4° DISPENSER SENSOR (i) BELDEN CABLE #88760 (1) #12 GND. � (NOT USED) ® 3/4" ADDITNE TANK MONITORING DEVICES (3) BELDEN CABLE #88760 (1) #12 GND Q 1" DISPENSER POWER 5,#12 THWN; 9 #14, (2} #14 TWISTED PAIR & 1 #12 GND. ® 1" CANOPY LIGHTS - FUTURE 25# PULL CORD � 3/4" DISPENSER SENSOR (1) BELDEN CABLE #88760 (1) #12 GND. © (NOT USED) ® 3/4" ADDITNE FLOW METER (1} BELDEN CABLE #88760 © 1" DISPENSER POWER 5 #12 THWN; 4 #14, (2) #14 T441STED PNR & 1 #12 GND, ® (NOT USED) ® 3/4" DISPENSER SENSOR (1) BELDEN CABLE #88760 (1) #12 GND. © 3/4" LOOP FOR POWER - UNLEADED A (3) #10 THWN, (1) #10 GND. © 3/4" ADDITNE SOLENOID VALUES CONTROL WIRING (4) #12 THWN + (1} #12 GND. (24V) ® 1" DISPENSER POWER 5 #12 TMWN; 4 #14, (2} #14 TWISTED PNR & 1 #12 GND. ® 3/4" ESO TO DISPENSERS (2} #12 7HVlN, (1) #12 GND. ® 3/4" pISPENSER SENSOR (1) BELDEN CABLE #88760 (1) #12 GND. ® 3/4" LOOP FOR POWER - UNLEADED B (3) #10 THWN, (1) #1d GND. ® 3/4" ADDITNE CONTROL PANEL POWER (4) #12 THWN + (1) #12 GND. 15 1" DISPENSER POWER 5 #12 THWN; 4 #14, (2} #14 TWISTED PNR & i #12 GND. ® 3/4" RECEPTACLE (2) #12 THWN, (1) #12 GND. © (NOT USED} ® 3/4" LOOP FOR POWER - PREMIUM C (3} #10 THWN, (1} #10 GND. i6 1" DISPENSER PQWER 512 THWN; 4 #14, (2} #19 TWISTED PAIR & 1 #12 GPJD. ® 1" LOOP TO RIGHT WALL RECEPTACLE (2) #12 THWN, (1} #12 GND. ® (NOT USED) ® 3/4" LOOP FOR POWER - ADDITIVE D TURB (2) #10 THWN, (1} #10 GND. ALL WIRE PULLS BY O.C. UNLESS OTHERWISE NOTED CONDUIT LEGEND • PLASTI -BOND ROBROY PVC COATED RKUD METALLIC CONDUIT REOUIRED FOR ALL UNDERGROUND CONDUITS LEAVNO ALL SUMPS (NO EXCEFDONS). TURBIINE POWER CONDUIT SHALL BE PLASTI-BOND ROBROY PVC COATED RIQID METALLIC CONDUIT ENTFIE RUN (NO EXCEPTIONS). ■ WHERE ALLOWED PER JURISDICTION, USE ROD SCHEDULE 40 PVC CONDW BETWEEN PLASTI -BOND ROBROY PVC COATED ROID METALLIC CONDUT AND THE PLASTI-BOND ROBROY PVC COATED FnD METALLIC TRANSITION. LL • • • • �� • LL • • • • LL