HomeMy WebLinkAboutFMC 2014MONITORING SYSTEM CERTIFICATION For Use By All Jurisdictions Within the State of California Authority Cited: Chapter 6. 7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. A. General Information Facility Name: _S.=..:..::h-=.e.:..:ll ____________________________ Bldg. No.: ____ _ Site Address: 8803 Camino Media Blvd. City: Bakersfield Zip: 93311 .:....:....:.....:....:..._ __ _ Facility Contact Person: _M_att_J_;e_ff_r_ie:....:s'---------------Contact Phone No.: (661) 758-3077 Make/Model of Monitoring System: --'V--=e--=e-'-d-"e-'-r--'-R.:..;o:....:o:....:t'-T_L=-S-'----=3--=5--=0---------Date of Testing/Servicing: 1/6/2014 B. Inventory of Equipment Tested/Certified c heck the appropriate boxes to indicate specific equipment inspected/serviced: Tank 10: 20,000 gal. Regular Tank 10: 12,000 gal. Su~er 181 In-Tank Gauging Probe. Model: 847390-107 181 In-Tank Gauging Probe. Model: 847390-107 181 Annular Space or Vault Sensor. Model: 794390-420 ~ Annular Space or Vault Sen~or. Model: 794390-420 181 Piping Sump I Trench Sensor(s). Model: 794380-208 181 Piping Sump I Trench Sensor(s). Model: 794380-208 181 I' ill Sump Sensor(s). Model: 794380-208 181 Fill Sump Sensor(s). Model: 794380-208 181 Mechanical Line Leak Detector. Model: FX1V 181 Mechanical Line Leak Detector. Model: FX1V D l lectronic Line Leak Detector. Model: D Electronic Line Leak Detector. Model: 181 fank Overfill /lligh-Level Sensor. Model: 847390-107 ~Tank Overfill / High-Level Sensor. Model: 847390-107 D Other (specif'y equipment type and model in Section Eon Page 2). D Other (specify equipment type and model in Section 1: on Page 2). Tank 10: 8,000 gal. Diesel Tank 10: 181In-Tank Gauging Probe. Model: 847390-107 D In-Tank Gauging Probe. Model: 181 Annular Space or Vault Sensor. Model: sent w/91 D Annular Space or Vault Senwr. Model: 181 Piping Sump I Trench Sensor(s). Model: 794380-208 D Piping Sump I Trench Sensor(s). Model: 181 Fill Sump Sensor(s). Model: 794380-208 D !'ill Sump Sensor(s). Model: 181 Mechanical Line Leak Detector. Model: FX1DV D Mechanical Line Leak Detector. Model: 0 Hectronic Line Leak Detector. Model: D Ucctronic Line Leak Detector. Model: 181 Tank Overfill II igh-Lcvel Sensor. Model: 847390-107 D Tank Overfill / High-Level Senw r. Model: 0 Other (specif'y equipment type and model in Section Eon Page 2). D Other (specif'y equipment type and model in Section Eon Page 2). Dispenser 10: 1-2 Dispenser 10: 3-4 181 Dispenser Containment Sensor(s). Model: 794380-208 181 Dispenser Containment Sensor(s). Model: 794380-208 181 Shear Valvc(s). 181 Shear Valvc(s). 0 Dispenser Containment Float(s) and Chain(s). D Dispenser Containment Float(s) and C'hain(s). Dispenser ID: 5-6 Dispenser ID: 7-8 181 Dispenser Containment Sensor(s). Model: 794380-208 181 Dispenser Containment Sensor(s). Model: 794380-208 181 Shear Valve(s). 181 Shear Valvc(s). 0 Dispenser Containment Float(s) and Chain(s). 0 Dispenser Containment Float(s) and Chain(s). Dispenser ID: Dispenser 10: 0 Dispenser Containment Sensor(s). Model: D Dispenser Containment Sensor(s). Model: 0 Shear Valve(s). D Shear Valve(s). 0 Dispenser Containment Float(s) and Chain(s). 0 Dispenser Containment rloat(s) and Chain(s). . . *If the facility contains more tanks or dtspensers, copy thts form. Include mformat10n for every tank and dtspcnscr at the facti tty. C. Certification -I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a copy of the report; (check all that apply): ~ System set-up ~ Alarm history report Technician Name Bradley Seykora Signature: ~::;;~~~--,....--a..~~====='------- Certification No.: B40738 License. N?.f-=-ao=-4.::9::..:0:...4.:...._ ____________ _ Testing Company Name: Confidence UST Services, Inc. Phone No.: ~C8:...0:...0:L)_3=..3:...9:...·..:.9..:.9=-30.:..._ ____ _ Site Address: 8803 Camino Media Blvd, Bakersfield, CA 93311 Date ofTesting/Servicing: 1/6/2014 Page 1 of 3 Monitoring System Certification D. Results of Testing/Servicing Software Version Installed: 327.04 ~~~--------------------------- c h ~ om pi ete t e ollowmg checklist: 181 Yes D No* Is the audible alarm operational? 181 Yes D No* Is the visual alarm operational? 181 Yes D No* Were all sensors visually inspected, functionally tested, and confirmed operational? 181 Yes D No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere with their proper operation? DYes D No* If alarms are relayed to a remote monitoring station, is all communications equipment (e.g., modem) 181 N/A operational? 181 Yes D No* For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment D N/A monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate positive shut-down? (Check all that apply) 181 Sumprfrench Sensors; 181 Dispenser Containment Sensors. Did you confirm positive shut-down due to leaks and sensor failure/disconnection? 181 Yes; D No. 181 Yes D No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e., no D N/A mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank fill point(s) and operating properly? If so, at what percent of tank capacity does the alarm trigger? 90% DYes* 181 No Was any monitoring equipment replaced? If yes, identifY specific sensors, probes, or other equipment replaced and list the manufacturer name and model for all replacement parts in Section E, below. DYes* 181 No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that app~v) D Product; D Water. If yes, describe causes in Section E, below. 181 Yes D No* Was monitoring system set-up reviewed to ensure proper settings? Attach set up reports, if applicable 181 Yes D No* Is all monitoring equipment operational per manufacturer's specifications? *In Section E below, describe how and when these deficiencies were or will be corrected. E. Comments: Page 2 of 3 Monitoring System Certification F. In-Tank Gauging I SIR Equipment: 1:8:1 Check this box if tank gauging is used only for inventory control. 0 Check this box ifno tank gauging or SIR equipment is installed. This section must be completed if in-tank gauging equipment is used to perform leak detection monitoring. Complete the following checklist: 1:8:1 Yes 0 No* Has all input wiring been inspected for proper entry and termination, including testing for ground faults? l8l Yes 0 No* Were all tank gauging probes visually inspected for damage and residue buildup? 1:8:1 Yes 0 No* Was accuracy of system product level readings tested? 1:8:1 Yes 0 No* Was accuracy of system water level readings tested? 1:8:1 Yes 0 No* Were all probes reinstalled properly? 1:8:1 Yes 0 No* Were all items on the equipment manufacturer's maintenance checklist completed? * In the Section H, below, describe how and when these deficiencies were or wiiJ be corrected. G. Line Leak Detectors (LLD): 0 Check this box ifLLDs are not installed. c h ~ II h kf omplete t e o owmg c ec 1St: 1:8:1 Yes 0 No* For equipment start-up or annual equipment certification, was a leak simulated to verifY LLD performance? 0 N/A (Check a// that apply) Simulated leak rate: 1:8:1 3 g.p.h.; 0 0.1 g.p.h ; 0 0.2 g.p.h. 1:8:1 Yes 0 No* Were all LLDs confirmed operational and accurate within regulatory requirements? 1:8:1 Yes 0 No* Was the testing apparatus properly calibrated? l8l Yes 0 No* For mechanical LLDs, does the LLD restrict product flow if it detects a leak? 0 N/A 0 Yes 0 No* For electronic LLDs, does the turbine automatically shut offifthe LLD detects a leak? l8l N/A 0 Yes 0 No* For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled 1:8:1 N/A or disconnected? 0 Yes 0 No* For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system 1:8:1 N/A malfunctions or fails a test? 0 Yes 0 No* For electronic LLDs, have all accessible wiring connections been visually inspected? 1:8:1 N/A 1:8:1 Yes 0 No* Were all items on the equipment manufacturer's maintenance checklist completed? * In the Section H, below, describe how and when these defic1enc1es were or w1ll be corrected. H. Comments: Page 3 of 3 Leak Detector Test Results Sheet Customer Address: Work Order: 31888 Site Address: Jeffries Bros., Inc. 145 Vultee Street Shafter, CA 93263 Test Date: 1/6/2014 Shell Site Contact: Matt Jeffries Technician: Bradley Seykora Phone: 661-758-3077 Phone: 800-339-9930 Product Type llDType Model Serial No. Regular UNL Mechanical FX1V Premium UNL Mechanical FXlV Diesel Mechanical FXlDV Check Valve 8803 Camino Media Blvd. Bakersfield, CA 93311 ICC No.: 8111231-UT Bleed leak Off Ml. Rate Holding Tested: Pressure 17 psi 70ml 3gph@ 10 psi 15 psi 105 ml 3gph@ 10 psi 13 psi 80ml 3gph@ 10 psi 3 gph@ 10 psi 3gph @ 10 psi 3gph@ 10 psi 3gph@ 10 psi 3gph@ 10 psi Technician Name: B~e~k~ Technician No.: Signature: __,;~~~;;::::;;~::-~~:::::::::==== Date: B40738 1/6/2014 7 Pass/Fail Pass Pass Pass BROOI$10E MARKET 8803 CAMINO NEOlA BAKERSFIELD CA 93311 JAN 6. 2014 8:53 AH SYSTEM STATUS REPORT ALL FUNCTIONS tlORI1AI. ltiVEilTORY REPORT T I :UNLEADED VOLUME • 14540 GALS ULLAGE " 5542 GALS 9W. ULLAGE• 3533 GALS TC VOLIJ1E • 14573 GALS HEIGl« • 86.69 INCHES WATER VOL • 16 GALS WATER • 0.77 INCHES TEMP " 56.7 DEG F T 2:PREHIUM VOLUME • 6005 CALS , .. :· ULLAGE 6036 GALS !~ 90% ULLAGE" 4831 GALS TC VOLUME • 6015 GALS HEIGHT • 63.62 ltiCHES WATER VOL " 9 GALS WATER " 0. 75 ltlCHES TEJ1P • 57.6 DEG F T 3:DIESEL VOLUME • 411 7 GALS ULLAGE • 3910 GALS 90:l ULLAGE• 3107 GALS TC VOLUME " 4109 GALS HEIGl« .. 65.04 INCHES WATER VOL • 0 GALS WATER • 0.00 INCHES TEMP " 64.1 DEG F )( )( )( )( )( EtiD )( )( )( )( )( SOFTWARE REVISION LEVEL VERSION 327.04 SOFTWARE~ 346327-100-E CREATED-07.02.06.10.28 S-MODULE~ 330160-004-a SYSTEM FEATURES: PERIODIC· JN;TAlll: TESTS ANNUAL IN-TANI~ TESTS ISO PMC SVSTEN SETUP ------------JAN 6. 2014 8:54 AH SVSTEN UNITS u.s. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/fiNE FORMAT HOU DD WW HH:NH:SS l</1 BROOKSIDE MARKET 8803 CAI'UtlO MEDIA BAKERSFIELD CA 93311 SHIFT TINE I : 2:00 AH SHIFT TIME 2 : DISABLED SHIFT TIME 3 : DISABLED SHIFT TIME 4 : DISABLED TANK PER TST NEEDED WRN DISABLED TANK ANN TST NEEDED WRN DISABLED LINE RE-ENABLE METHOD PASS LitlE TEST LINE PER TST NEEDED WRN DISABLED Ll NE ANN TST NEEDED WRN DISABLED PRitlT TC VOLUMES ENABLED TEMP COMPENSATION VALUE <DEG F >: 60.0 STICK HEIGHT OFFSET DISABLED ULLAGE: 90" H-PROTOCOL DATA FORMAT HEIGHT DAYLIGHT SAVING TIME ENABLED START DATE APR WEEK I SUN START TIME 2:00 AH END DATE OCT WEEK 6 SUtl END TINE 2:00 AH RE-DIRECT LOCAL PRWTOUT DISABLED EURO PROTOCOL PREFIX s SYSTEM SECURITY CODE : 000000 MAINTENANCE HISTORY DISABLED TAtn: CW\RT SECURITY DISABLED CLSTOH ALARMS DISABLED MASS/DENSITY DISABLED COMMUNICATIONS SETUP PORT SETTINGS: CONH BOARD : I <EDIM > RS-232 SECURITY CODE : DISABLED CONH BOARD : 2 <S-SAT BAUD RATE : 9600 PARITY : NONE STOP BIT : I STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED DTR NORMAL STATE: HIGH OOMM BOARD : 3 <RS-232> BAUD RATE : 9600 PARITY : NONE STOP BIT : I STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED AUTO TRANSMIT SETTit~: AUTO LEAK ALARM LIMIT DISABLED AUTO HIGH WATER LIMIT DISABLED AUTO OVERFILL LIMIT DISABLED AUTO LOW PRODUCT DISABLED AUTO THEFT LIMIT DISABLED AUTO DELIVERY START DISABLED AUTO DELIVERY EtlD DISABLED AUTO EXTERNAL JIIPUT ON DISABLED AUTO EXTERNAL I tiPUT OFF DISABLED AUTO SENSOR FUEL ALARM DISABLED AUTO SENSOR WATER ALARM DISABLED AUTO SENSOR OUT ALARM DISABLED RECEIVER SETUP: NONE AUTO DIAL TIME SETUP: NONE RS-232 EtlD OF MESSAGE DISABLED AUTO DIAL ALARH SETUP IN-TAta{ SETUP T I :UtlLEADED PRODUCT CODE THERMAL COEFF TAM: DIAMETER TANK PROFILE FULL VOL I .000700 127.50 I PT 20082 FLOAT SIZE: 4.0 ttl. WATER-wARtU 00 • HIGH WATER LIHIT: MAX OR LABEL VOL: OVERFILL LIHIT : HIGH PRODUCT • DELIVER'! LIHIT . 2.0 3.0 20082 so:; 18073 SSY. IS078 tOY. 2008 LOW PRODUCT • 500 LEAK ALARM LIHIT: S9 SUDDEt~ LOSS LIMIT! 50 TANK TILT 0.00 PROBE OFFSET 0.00 SIPHON MANIFOLDED TANKS Til: flOtlE LINE HAtliFOLDED TAtiJ<S Til: NONE LEAK Mltl PERIODIC: LEAK HIN ANNUAL : lOY. 2008 lOY. 2008 PERIODIC TEST T'/PE STANDARD ANNUAL TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED GROSS TEST FAIL ALARM DISABLED ANti TEST AVERAGING: OFF PER TEST AVERAGWG: OFF TANK TEST NOTIFY: OFF TNK TST SIPHON BREAY.:OFF DELIVERY DELAY : 15 HIN Pl.tlP THRESHOLD : IO.OOY. T 2:PREtUUM PRODUCT CODE THERMAL COEFF TANK DIAMETER TANK PROFILE FULL VOL FLOAT SIZE: WATER WARNING : HIGH WATER LIHIT: MAX OR LABEL VOL: OVERFILL LIHIT : HIGH PRODUCT DELIVERY LIMIT LOW PRODUCT : LEAK ALARM LIMIT: 2 .000700 127.50 I PT 12041 4.0 IN. 2.0 3.0 12041 90Y. 10837 SSY. 1143S 10% 1204 SUDDEN LOSS LIHIT: 500 99 50 o.oo TANK TILT PROBE OFFSET o.oo SIPHON MANIFOLDED TANKS Til: NONE LitlE MANIFOLDED TA!lKS Til: NONE LEAK HIN PERIODIC: . . LEAK HIN ANNUAL : 10'4 1204 lOY. 1204 PERIODIC TEST TYPE STANDARD ANNUAL TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED GROSS TEST FAIL ALAAt1 DISABLED ANf~ TEST AVERAGING: OFF PER TEST AVERAGitlG: OFF TANK TEST NOTIFY: OFF TNY. TST SIPHON EREAK:OFF DELIVERY DELAY : 15 HIN PUMP THRESHOLD : 10.00% T 3:0IESEL PRODUCT CODE THERMAL COEFF TANK DIAMETER TANio: PROFILE FULL VOL FLOAT SIZE: WATER WARtH NG : HIGH WATER LIHIT: HAX OR LABEL VOL: OVERFILL LIMIT HIGH PRODUv-r DELIVERY LIMIT 3 .000450 127.50 I PT 8027 4,0 IN. 2.0 3.0 8027 SOY. 7224 SSY. 7625 JOY. 802 LOW PRODU...-r : 500 LEAX Al.AJ<t\ LIMIT: 99 SUDDEN LOSS LIMIT: 50 TANK TILT 0.00 PROBE OFFSET 0.00 SIPHON MANIFOLDED TANKS Tit: NONE LINE MANIFOLDED TAtlKS Tit: NONE LEAl: Hltl PERIODIC: 10% 802 LEAK Hltl ANNUAL : I OY. 802 PERIODIC TEST TYPE STANDARD AtlllUAL TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED GROSS TEST FAIL ALARM DISABLED ANN TEST AVERAGING: OFF PER TEST AVERAGING: OFF TANK TEST NOTIFY: OFF TNK TST SIPHON BREA}::OFF DELIVERY DELAY : 15 MIN PU1P THRESHOLD : I 0. 00% LEAK TEST METHOD TEST ANNUALLY: ALL TAU!: DEC WEEK 2 WED START TINE : 2:30 Al1 TEST RATE :0.20 CAL/HR DURATION : 2 HOURS TST EARLY STOP!OISABLED LEAK TEST REPORT F0~1AT ENHANCED LIQUID SEIISOR SETUP L l :87 ANilULAR TRI-STATE <SINGLE FLOAT> CATEGORY : ANNULAR SPACE L 2!87 STP TRI-STATE <SINGLE FLOAT> CATEGORY : STP SU1? L 3:87 FILL TRI-STATE <SINGLE FLOAT> CATEGORY : OTHER SENSORS L 4!91-DIESEL ANNULAR TRI-STATE <Sl NGLE FLOAT> CATEGORY : ANNULAR SPACE L 5!91 STP TRI-STATE <SWGLE FLOAT) CATEGORY : STP SUMP L 6!91 FILL TRI-STATE <SINGLE FLOAT> CATEGORY : OTHER SENSORS L ?:DIESEL STP TRI-STATE <SINGLE FLOAT> CATEGORY : STP SLt1P L B!DIESEL FILL TRI-STATE <SINGLE FLOAT> CATEGORY : OTHER SEtiSORS L 9!DISP 1-2 TRI-STATE <SINGLE FLOAT> CATEGORY : DISPENSER PAN LlO!DISP 3-4 TRI-STATE <Sl NGLE FLOAT> CATEGORY : DISPENSER PAN Ltt:DJSP 5-6 TRI-STATE <SINGLE FLOAT> CATEGORY : DISPEtSER PAN L12!DISP 7-8 TRI-STATE <Sl NGLE FLOAT> CATEGORY : DISPEtSER PAtl OUTPUT RELAY SETUP R l :87 STP TYPE: STANDARD NORMALLY CLOSED TANK II! LIQUID SENSOR ALMS L 1 !FUEL ALARM L 2!FUEL ALARM L 9!FUEL ALARM LtO:FUEL ALARM Lll !FUEL ALARM Ll2!FUEL ALARM L 1 :SENSOR OUT ALARM L 2!SENSOR OUT ALARt1 L 9:SENSOR OUT ALARM LlO!SENSOR OUT ALARM Lll !SENSOR OUT ALARM Ll2!SEtlSOR OUT ALARM lSD SITE ALARMS ISO GROSS PRES FAIL lSD DEGRD PRES FAIL lSD VAPOR LEAK FAIL lSD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL!DEGRD COLLECT FAIL R 2!91 STP TYPE: STANDARD NORMALLY CLOSED TANK II! 2 LIQUID SENSOR ALMS L 4 :FUEL ALARM L 5!FUEL ALARM L 9 !FUEL ALARM LIO!FUEL ALARM Lit !FUEL ALARM L 12: FUEL ALARM L 4 !SENSOR OUT ALARM L 5 !SENSOR OUT ALARM L 9 :SENSOR OUT ALARM LtO:SEtiSOR OUT ALARM Lll :SENSOR OUT ALARM L12!SENSOR OUT ALARM lSD SITE ALARMS lSD GROSS PRES FAIL ISO DEGRD PRES FAIL ISO VAPOR LEAK FAIL lSD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL!DEGRO COLLECT FAlL R 3!DlESEL STP TYPE: STANDARD NORMALLY CLOSED TANK 11: 3 LIQUID SENSOR ALMS L 4!FUEL ALARM L 7:FUEL ALARM Ll2!FUEL ALARM L 4 :SENSOR OUT ALARM L ?!SENSOR OUT ALARM LI2!SENSOR OUT ALARM SHARTSENSOR SETUP :s l!DISP 1-2 FM CATEGORY AIR FLOW METER 5 2:DISP 3-4 FM CATEGORY AIR FLOW METER s 3:DISP 5-6 FM CATEGORY AIR FLOW METER s 4:DISP 7-8 FM CATEGORY AIR FLOW METER 5 S:PRESS SENSOR CATEGORY VAPOR PRESSURE EVR/ I SD SETUP EVR T'IPE: VACUll1 ASSIST VACUUM ASSIST TYPE HEALV VAC NOZZLE A/L RANGE MAX: 1.15 MIN: 0.95 VAPOR PROCESSOR TYPE NO VAPOR PROCESSOR ANALYSIS TIMES TIME: 10:00 AM DELAV MINlJTES: ACCEPT HIGH ORVR : DISABLED lSD HOSE TABLE JD FP FL HL AA RR ------------------------OJ 01 01 02 0<1 uu 02 02 02 02 04 uu 03 03 03 02 OJ uu 0<1 04 04 02 OJ uu 05 05 05 02 02 uu 06 06 06 02 02 uu 07 07 07 02 03 uu 09 09 08 02 03 uu lSD AIRFLOW METER MAP ID SERIAL NUM LABEL ------------------------1 9129 DISP 3-4 F 2 13413 DISP 5-6 F 3 9132 DISP 7-8 F 4 9130 DISP 1-2 F lSD FUEL GRADE HOSE MAP 1 2 3 4 FP MHH MHH MHH MHH AA 01 101 901 201 u u 4 02 102 902 202 u u 4 03 103 903 203 u u l 0<1 104 904 204 u u l 05 105 905 205 u u 2 06 106 906 206 u u 2 07 107 907 207 3 u 3 09 109 906 206 3 u 3 LABEL TABLE ------------------------1: UNASSIGNED 2: ELEND3 3: REGULAR 4: HID GRADE 5: PREHIU1 6: GOLD 7: BRONZE 9! SILVER 9! BLEND2 10: BLEND4 Pt1C SETUP PROCESSOR CONTROL LEVEL: t.ONE ALARM HISTOP.Y REPORT -----SENSOR ALARN -----L I :87 ANNULAR ANNULAR SPACE SENSOR OUT ALARM JAN 8. 2013 9!41 AM FUEL ALARM JAN B. 2013 9:34 AM ALARM HISTORY REPORT -----SENSOR ALARM -----L 2:a7 STP STP SUMP SENSOR OUT ALARM JAN a. 2013 9:41 AM FUEL ALARM JAN a. 2013 9!26 AM ALARM HISTORY REPORT -----SENSOR ALARM -----L 3!87 FILL OTHER SENSORS SENSOR OUT ALARM JAN a. 2013 9!41 AH FUEL ALARM JAN a. 2013 9!32 AM ALARM HISTORY REPORT -----SEtSOR ALARM -----L 4!91-DIESEL ANNULAR ANNULAR SPACE SEtSOR OUT ALARM JAN e. 2013 9!41 AM FUEL ALARM JAN e. 2013 9:35 AM ALARM HISTORY REPORT -----SEtSOR ALARM -----L 5:91 Sfp STP St.ttP SENSOR OUT Al.AP.t1 JAN e. 2013 9:41 AH FUEL ALARM JAN e. 2013 9:27 AH ALARM HISTORY REPORT -----SENSOR ALARM -----L 6:91 FILL OTHER SENSORS SEtlSOR OUT ALARM JAI~ e. 2013 9!41 AH FUEL ALARM JAU e. 2013 9:31 AH ALARM HISTORV REPORT -----SENSOR ALARH -----L ?:DIESEL STP STP SLtiP SEtlSOR OUT ALARM JAN e. 2013 9:41 AM FUEL ALARM JAN e. 2013 9:29 AM ALARM HISTORY REPORT -----SEtlSOR ALARM -----L e:OIESEL FILL OTHER SENSORS SENSOR OUT ALARM JAN a. 2013 9!41 f>l1 FUEL AlARM JAtl e. 2013 9:29 AH ALARM HISTORY REPORT ----SEtlSOR ALARM -----L 9!DISP 1-2 DISPENSER PAtl SEtlSOR OUT ALARM JAN e. 2013 9!41 AM FUEL AlARM JAN e. 2013 9!38 AM ALARM HISTORY REPORT -----SENSOR ALARM -----LIO:DISP 3-4 DISPENSER PAN FUEL ALARM JAN e. 2013 10:57 AM SENSOR OUT ALARM JAN 9. 2013 9:41 AM FUEL ALARH JAN e. 2013 9:38 AM ~ ~ ~ M ~ END K * * * * ALARM HISTORY REPORT -----SENSOR ALARM -----LII!DISP 5-6 DISPEtlSER PAN SENSOR OI.Ir ALARM JAN e. 2013 9!41 AM FUEL ALARM JAN e. 2013 9!36 AM ALARM HISTOR'/ REPORT -----SENSOR ALARM -----LI2!DISP 7-e DISPENSER PAN SENSOR OI.Ir ALARM JAN e. 2013 9!41 AH FUEL ALARM JAN e. 2013 9!37 AM -----SEIISOR ALARM ----L 9!DJSP 1-2 DISPENSER PAll SEIISOR OUT ALARM JAN 6. 2014 9!41 AH -----SElSOR ALARM -----L 5!91 STP STP Sli1P SENSOR OUT ALARtl JAN 6. 2014 9!42 AH -----SENSOR ALARM -----L10!DISP 3-4 DISPENSER PAN SENSOR OUT ALARM JAN 6. 2014 9!42 AH -----SENSOR ALAI"d1 L 1 : e7 ANNULAR ANIIULAR SPACE 1 SENSOR OUT ALARM JAN 6. 2014 9!42 AM -----SENSOR ALARM -----L 3:e7 FILL OTHER SENSORS SEtlSOR OI.Ir ALARM JAil 6. 2014 9!42 AM ----SElSOR ALARM ----- L 4!91-DIESEl. ANNULAR ANNULAR SPACE SEUSOR OUT ALARM JAN 6. 2014 9!42 AM -----SElSOR ALARM ----- L11 !DISP 5-6 DISPEIISER PAN SEtlSOR OI.Ir ALAI\11 JAN 6. 2014 9: •12 tlt1 -----SElSOR ALARI1 ----- L12!DISP 7-8 DISPENSER PAN SENSOR OI.Ir ALARM JAN 6. 2014 9:42 AH -----SENSOR ALARM -----L 6!91 FILL OTHER SENSORS SENSOR OI.Ir ALARM JAN 6. 2014 9!42 AM -----SENSOR ALARM -----L ?!DIESEl. STP STP Sll'IP SENSOR OUT ALARM JAN 6. 2014 9!42 AN -----SENSOR ALARM -----L S!DIESEL FILL OTHER SEtlSORS SENSOR OUT ALARM JAil 6. 2014 9!42 AH -----SENSOR ALARM -----L 2:e7 STP STPSUNP SEtlSOR OI.Ir ALARM JAN 6. 2014 9!42 AM -----SENSOR ALAIIM -----L 2:87 STP STPSUI1P FUEL ALAIIM JAN 6. 2014 9!47 AM -----SElSOR ALARH -----l:J. ?:DIESEL STP '"STP SUMP , FUEL ALARM JAil 6. 2014 ~:.16 1111 .:-:- ----SENSOR ALARM -----L 5:91 STP STP SUI1P FUEL ALAIIM JAN 6. 2014 9:50 AM -----SENSOR ALARM -----LI2:DISP 7-8 DISPENSER PAN FUEL ALARM JAN 6. 2014 9:52 AH -----SENSOR ALARM -----Ll1 :DISP 5-6 DISPENSER PAN FUEL ALARM JAN 6. 2014 9:53 AM -----SENSOR ALAIIM -----L10!DISP 3-4 DISPEtlSER PAN FUEL ALARM JAN 6. 2014 9:54 AM -----SENSOR ALARM -----L 9!D1SP 1-2 DISPENSER PAN FUEL ALARM JAN 6. 2014 9:57 AM ----SEtlSOR ALARM -----L B:DIESEL FILL OTHER SENSORS FUEL ALARM JAN 6. 2014 9!59 AM ----SENSOR ALARt1 ----- L 6:91 FILL OTHER SENSORS FUEL ALARM JAtl 6. 2014 9:59 AM ----SENSOR ALARM -----L 3:87 FILL OTHER SENSORS FUEL ALARM JAN 6. 2014 10:00 AM -----SENSOR ALARM -----L I : 87 ANtlULAR ANNULAR SPACE FUEL ALARM JAN 6. 2014 10:01 AM -----SENSOR ALARM -----L 4!91-DIESEL ANNULAR ANNULAR SPACE FUEL ALARM JAN 6. 2014 10:03 AM BROOKSIDE MARKET 8803 CAMINO MEDIA BAKERSFIELD CA 93311 JAN 6. 2014 10:04 AM S'ISTEM STATUS REPORT ------------ALL FUNCTIONS NORMAL BROOKSIDE MARKET 8803 CAMillO t1EDIA BAKERSFIELD CA 93311 JAN 6. 2014 11:15 AM S\'STEH STATUS REPORT ALL FUtlCTIONS NORMAL SWRC B, January 2006 Spill Bucket Testing Report Form This form is intended for use by contractors performing annual testing of UST spill containment structures. The completedform and printouts f rom tests ar applicable), should be provided to the facility owner/operator for submit/alto the local regulatOiy agency. 1 FACILITY INFORMATION . Facility Name: Shell I Date ofTesting: 1/6/2014 Facility Address: Camino Media Blvd., Bakersfield, CA 933 11 Facility Contact: Matt Jeffries _I Phone: 66 1-496-7006 Date Local Agency Was Notified of Testing: Ester Duran Name of Local Agency Inspector (if present during testing): 1/2/2014 2. TESTING CONTRACTOR INFORMATION Company Name: Confidence UST Services, Inc. Technician Conducting Test: Bradley Seykora Credentials': ~ CSLB Contractor ~ICC Service Tech. [' SWRCB Tank Tester 0 Other (Specify) License Number(s): CSLB# 804904 ICC# 8111231 -UT 3. SPILL BUCKET TESTING INFORMATION Test Method Used: ~ Hydrostatic Vacuum [ Other Test Equipment Used: Lake Test Equipment Resolution: 0.0625" Identity Spill Bucket (By Tank 1 Regular 2 Super 3 Diesel 4 Number, Stored Product, etc.) Bucket Installation Type: Direct Bury l Direct Bury u Direct Bury Direct Bury X Contained in Sump X Contained in Sump X Contained in Sump l Contained in Sump Bucket Diameter: 12.00" 12.00" 12.00" Bucket Depth: 12 .00" 12.00" 12.00" Wait time between applying 5 Min. 5 Min. 5 Min. vacuum/water and start of test: Test Start Time (T1): 9:45am 9:45am 9:45am Initial Reading (R1): 9.25" 9.50" 8.25" Test End Time (TF): I 0:45am I 0:45am I 0:45am Final Reading (Rr): 9.25" 9.50" 8.25" Test Duration (T F-T1): 1 Hour I Hour I Hour Change in Reading (Rr-R1): 0.00" 0.00" 0.00" Pass/Fail Threshold or 0.0625" 0.0625" 0.0625" Criteria: Test Result: X Pass 0 Fail X Pass 0 Fail X Pass 0 Fail 0 Pass 0 Fail Comments -(include infomwtion on repairs made prior to testing, and recommended follow-up for.fai/ed tests) CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING I hereby certify that all the information contained in this report is true, accurate, and in full compliance with legal requirements Technician's Signature: ~ Date: 1/6/2014 __ __...A<~~- 1 State Jaws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements may be more stringent. Shell 8803 Camino Media Blvd. Bakersfield, CA 93311 1 TLS 350 2. 208 Sump Sensor 3. 420 Annuar Sensor 4. TankATG 5 Red Jacket FX1V 6 Red Jacket FX1DV 7 ESO Swithc -~ 2. ·~ 2. (f\ ~ ( 2. 4 . ~CJ -- G (1~ ~~) (f:\ I \ I I \ e J' ~_/ (2:-\ 5. \ ~TP) --- ~~-\ I 4 · I ~-~-) 1\ I 3.)