Loading...
HomeMy WebLinkAboutFMC 2014Testing and Inspection Certificate Tanknology Inc. 11000 North MoPac Expressway, Suite 500, Austin, TX 78759 800-800-4633 www.tanknology.com Page 1 of 1 Test Date 4/23/2014 Tanknology WO#SC1-3418303 Test Purpose COMPLIANCE Customer PO# Customer Location 7-ELEVEN, INC. P.O. BOX 711 DALLAS, TX 75221 7-ELEVEN #32376, MKT 2368 9600 BRIMHALL RD. BAKERSFIELD, CA 93312 Attn: ENVIRONMENTAL DEPARTMENT Attn: Nanjot 11/13/13 (972) 828-7575 (661) 588-4059 Test / Inspection Description Item Tested Date Tested Result Line Leak Detector (3 GPH) Tank T2 RUL Line 1 RUL 4/23/2014 Pass Line Leak Detector (3 GPH) Tank T3 PUL Line 1 PUL 4/23/2014 Pass Impact Valve Inspection See test report for details 4/23/2014 Pass Leak Detection Monitoring System Inspection See test report for details 4/23/2014 Pass Spill Containment / Bucket RUL SB 1 - Fill - Direct 4/23/2014 Pass Spill Containment / Bucket PUL SB 1 - Fill - Direct 4/23/2014 Pass E-Stop Inspection See test report for details 4/23/2014 Pass Tanknology Representative: Aaron Medina Technician: Edwin Pineda Telephone: (800) 964-0010 Technician Certification: (See forms) LDT 5000 Field Test Apparatus Line Leak Detector Test Page 1 of 1 Work Order:3418303 Date:4/23/2014 Site Name / ID:7-ELEVEN #32376, MKT 2368 / 32376 Address:9600 BRIMHALL RD. City:BAKERSFIELD State:CA Zip:93312 Tank ID Product Product Line Tested From Existing/New Mechanical/Electronic Manufacturer/Model Serial No. Pump Operating Pressure (psi) Calibrated Leak (ml/min) Calibrated Leak (gph) Holding PSI *N/A for Electronic LD's Resiliency (ml) *N/A for Electronic LD's Metering PSI *N/A for Electronic LD's Opening Time (sec) *N/A for Electronic LD's Test Results T2 RUL RUL 1 3 Existing Mechanical Vaporless LD-2000 02164 29.00 189.0 3.00 29.00 360.00 19 14 Pass T3 PUL PUL 1 3 Existing Mechanical Vaporless LD-2000 08041485 30.00 189.0 3.00 29.00 220.00 21 24 Pass Technician Comments: Technician Name:Edwin Pineda Certification #:2344 Technician Signature:Expire Date:4/5/2015 Environmental Compliance for Petroleum Systems © 2014 Tanknology Inc., Austin, TX.    All rights reserved.    tanknology.com Impact Valve Inspection Impact Valve Operational Inspection Work Order:3418303 Date:4/23/2014 Site Name/ID:7-ELEVEN #32376, MKT 2368 Address:9600 BRIMHALL RD. City:BAKERSFIELD State:CA Zip:93312 Dispenser Number Grade Secure Mount? Valve Lock?Pass/ Fail Comments 1/2 87 Pass Fail Not Tested 1/2 91 Pass Fail Not Tested 3/4 87 Pass Fail Not Tested 3/4 91 Pass Fail Not Tested 5/6 87 Pass Fail Not Tested 5/6 91 Pass Fail Not Tested 7/8 87 Pass Fail Not Tested 7/8 91 Pass Fail Not Tested 9/10 87 Pass Fail Not Tested 9/10 91 Pass Fail Not Tested 11/12 87 Pass Fail Not Tested 11/12 91 Pass Fail Not Tested Technician Comments: Technician Name:Edwin Pineda Signature: Environmental Compliance for Petroleum Systems ©2014 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com Appendix VI (Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at http://www.swrcb.ca.gov.) MONITORING SYSTEM CERTIFICATION For Use By All Jurisdictions Within the State of California Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. A. General Information Facility Name:7-ELEVEN #32376, MKT 2368 Bldg. No.: Site Address:9600 BRIMHALL RD.City:BAKERSFIELD Zip:93312 Facility Contact Person:Nanjot 11/13/13 Contact Phone No.:661-588-4059 Make/Model of Monitoring System:Veeder Root TLS 350 Date of Testing/Servicing:4/23/2014 B. Inventory of Equipment Tested/Certified Check the appropriate boxes to indicate specific equipment inspected/serviced: Tank ID:T2 RUL - RUL In-Tank Gauging Probe.Model:MAG Annular Space or Vault Sensor.Model:VR-420 Piping Sump / Trench Sensor(s).Model:VR-352 Fill Sump Sensor(s).Model:VR-208 Mechanical Line Leak Detector.Model:Vaporless LD-2000 Electronic Line Leak Detector.Model: Tank Overfill / High-Level Sensor.Model:PROBE/FLAPPER Other (specify equipment type and model in Section E on Page 2). Tank ID:T3 PUL - PUL In-Tank Gauging Probe.Model:MAG Annular Space or Vault Sensor.Model:VR-420 Piping Sump / Trench Sensor(s).Model:VR-352 Fill Sump Sensor(s).Model:VR-208 Mechanical Line Leak Detector.Model:Vaporless LD-2000 Electronic Line Leak Detector.Model: Tank Overfill / High-Level Sensor.Model:PROBE/FLAPPER Other (specify equipment type and model in Section E on Page 2). Tank ID: In-Tank Gauging Probe.Model: Annular Space or Vault Sensor.Model: Piping Sump / Trench Sensor(s).Model: Fill Sump Sensor(s).Model: Mechanical Line Leak Detector.Model: Electronic Line Leak Detector.Model: Tank Overfill / High-Level Sensor.Model: Other (specify equipment type and model in Section E on Page 2). Tank ID: In-Tank Gauging Probe.Model: Annular Space or Vault Sensor.Model: Piping Sump / Trench Sensor(s).Model: Fill Sump Sensor(s).Model: Mechanical Line Leak Detector.Model: Electronic Line Leak Detector.Model: Tank Overfill / High-Level Sensor.Model: Other (specify equipment type and model in Section E on Page 2). Dispenser ID:1/2 Dispenser Containment Sensor(s).Model:VR-352 Shear Valve(s). Dispenser Containment Float(s) and Chain(s). Dispenser ID:3/4 Dispenser Containment Sensor(s).Model:VR-352 Shear Valve(s). Dispenser Containment Float(s) and Chain(s). Dispenser ID:5/6 Dispenser Containment Sensor(s).Model:VR-352 Shear Valve(s). Dispenser Containment Float(s) and Chain(s). Dispenser ID:7/8 Dispenser Containment Sensor(s).Model:VR-352 Shear Valve(s). Dispenser Containment Float(s) and Chain(s). Dispenser ID:9/10 Dispenser Containment Sensor(s).Model:VR-352 Shear Valve(s). Dispenser Containment Float(s) and Chain(s). Dispenser ID:11/12 Dispenser Containment Sensor(s).Model:VR-352 Shear Valve(s). Dispenser Containment Float(s) and Chain(s). *If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers’ guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a copy of the report; (check all that apply): System set- up Alarm history report Technician Name (print):Edwin Pineda Signature: Certification No.: B37453 License. No.:743160 Class 'A' Testing Company Name:Tanknology Phone No.:(800) 800-4633 Testing Company Address:11000 N. MoPac Expressway Suite 500 Date of Testing/Servicing:4/23/2014 Monitoring System Certification Page 1 of 3 12/07 D. Results of Testing/Servicing Software Version Installed:329.02 Complete the following checklist: Yes No*Is the audible alarm operational? Yes No*Is the visual alarm operational? Yes No*Were all sensors visually inspected, functionally tested, and confirmed operational? Yes No*Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere with their proper operation? Yes No* N/A If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) operational? Yes No* N/A For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate positive shut-down? (Check all that apply) Sump/Trench Sensors; Dispenser Containment Sensors. Did you confirm positive shut-down due to leaks and sensor failure/disconnection? Yes; No Yes No* N/A For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank fill point(s) and operating properly? If so, at what percent of tank capacity does the alarm trigger? % Yes* No Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced and list the manufacturer name and model for all replacement parts in Section E, below. Yes* No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) Product; Water. If yes, describe causes in Section E, below. Yes No*Was monitoring system set-up reviewed to ensure proper settings? Attach set up reports, if applicable Yes No*Is all monitoring equipment operational per manufacturer's specifications? * In Section E below, describe how and when these deficiencies were or will be corrected. E. Comments: Monitoring System Certification Page 2 of 3 12/07 F. In-Tank Gauging / SIR Equipment: Check this box if tank gauging is used only for inventory control. Check this box if no tank gauging or SIR equipment is installed. This section must be completed if in-tank gauging equipment is used to perform leak detection monitoring. Complete the following checklist: Yes No*Has all input wiring been inspected for proper entry and termination, including testing for ground faults? Yes No*Were all tank gauging probes visually inspected for damage and residue buildup? Yes No*Was accuracy of system product level readings tested? Yes No*Was accuracy of system water level readings tested? Yes No*Were all probes reinstalled properly? Yes No*Were all items on the equipment manufacturer's maintenance checklist completed? * In the Section H, below, describe how and when these deficiencies were or will be corrected. G. Line Leak Detectors (LLD): Check this box if LLDs are not installed. Complete the following checklist: Yes No* N/A For equipment start-up or annual equipment certification, was a leak simulated to verify LLD performance? (Check all that apply) Simulated leak rate: 3 g.p.h.; 0.1 g.p.h; 0.2 g.p.h. Yes No*Were all LLDs confirmed operational and accurate within regulatory requirements? Yes No*Was the testing apparatus properly calibrated? Yes No* N/A For mechanical LLDs, does the LLD restrict product flow if it detects a leak? Yes No* N/A For electronic LLDs, does the turbine automatically shut off if the LLD detects a leak? Yes No* N/A For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? Yes No* N/A For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a test? Yes No* N/A For electronic LLDs, have all accessible wiring connections been visually inspected? Yes No*Were all items on the equipment manufacturer's maintenance checklist completed? * In the Section H, below, describe how and when these deficiencies were or will be corrected. H.Comments: Page 3 of 3 12/07 SWRCB, January 2002 Page 1 of 1 Secondary Containment Testing Report Form This form is intended for use by contractors performing periodic testing of UST secondary containment systems. Use the appropriate pages of this form to report results for all components tested. The completed form, written test procedures, and printouts from tests (if applicable), should be provided to the facility owner/operator for submittal to the local regulatory agency. 1. FACILITY INFORMATION Facility Name: 7-ELEVEN #32376, MKT 2368 Date of Testing: 4/23/2014 Facility Address: 9600 BRIMHALL RD. , BAKERSFIELD, CA 93312 Facility Contact: Nanjot 11/13/13 Phone: 661-588-4059 Date Local Agency Was Notified of Testing: Name of Local Agency Inspector (if present during testing): Esther Duran 2. TESTING CONTRACTOR INFORMATION Company Name: TANKNOLOGY INC. Technician Conducting Test: Edwin Pineda Credentials: CSLB Licensed Contractor SWRCB Licensed Tank Tester License Type: A-UT License Number: 743160-8026748 Manufacturer Manufacturer Training Component(s)Date Training Expires OPW SPILL BUCKETS 1/25/2015 3. SUMMARY OF TEST RESULTS Component Pass Fail Not Tested Repairs Made Spill Box T2 RUL rul fill X Spill Box T3 PUL pul fill X Component Pass Fail Not Tested Repairs Made If hydrostatic testing was performed, describe what was done with the water after completion of tests: CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING To the best of my knowledge, the facts stated in this document are accurate and in full compliance with legal requirements Technician's Signature:Date:4/23/2014 WO: 3418303 WATER WAS PUT IN FIVE GALLON BUCKETS AND PUT IN TRUCK FOR NEXT SITE. SWRCB, January 2002 Page 1 of 1 9. SPILL/OVERFILL CONTAINMENT BOXES Facility is Not Equipped With Spill/Overfill Containment Boxes Spill/Overfill Containment Boxes are Present, but were Not Tested Test Method Developed By: Spill Bucket Manufacturer Industry Standard Professional Engineer Other (Specify): Test Method Used By: Pressure Vacuum Hydrostatic Other (Specify): Test Equipment Used: LAKE TEST Equipment Resolution: 0.0625 in. Bucket Diameter: Bucket Depth: Wait time between applying pressure/vacuum/water and starting test Test Start Time: Initial Reading (RI): Test End Time: Final Reading (RF): Test Duration: (RF-RI) : Pass/Fail Threshold or Criteria: Test Result: Spill Box # Tank T2 RUL RUL - Fill 1 - Direct - Below Grade in containment sump 14.00 15.00 0 min 09:15:00 14.00 in. H20 10:15:00 14.00 in. H20 1 hr 0.00 in. H20 +/- 0.00 Pass Spill Box # Tank T3 PUL PUL - Fill 1 - Direct - Below Grade in containment sump 13.00 15.00 0 min 09:15:00 14.00 in. H20 10:15:00 14.00 in. H20 1 hr 0.00 in. H20 +/- 0.00 Pass Spill Box # min +/- Spill Box # min +/- Comments - (include information on repairs made prior to testing, and recommended follow-up for failed tests) WO: 3418303 7-Eleven Test Water Log Work Order: Site Name/ID: Address: City: 3418303 7-ELEVEN #32376, MKT 2368 9600 BRIMHALL RD. BAKERSFIELD Date: 4/23/2014 State: CA Zip: 93312 Work Performed:ATG, E-Stop, Impv, LDs, SB's, Sub Form Was Test Water left on site? Yes Test Fluid Transported Off Site by Tanknology Transported off Site by Other Company No Water used If Yes describe how much water and how contained? If Yes who and when did you contact from site to report the water? If Transported Off Site by Tanknology how much was hauled? If Transported Off Site by Other Company what company and how much water? Technician Signature: Date: 4/23/2014 WO: 3418303 Emergency Stop (E-Stop / ESO) Periodic Inspection Facility Information Technician Information Site #: 7-ELEVEN #32376, MKT 2368 32376 Date: 4/23/2014 Address: 9600 BRIMHALL RD. Name: Edwin Pineda City / State: BAKERSFIELD CA Technician Signature: The objective of this test is to provide assurance that the when the E-Stop switch is activated, all the fueling system circuits (turbines, and dispensers) are de-energized, and remain de-energized until they are re-set manually). The test procedures and guidelines shall be in accordance with the E-Stop Testing Process. SITE DATA 1 Number of E-Stop switches INSIDE of the building: 0 2 Number of E-Stop switches OUTSIDE of the building: 1 PERFORMANCE DATA Yes No NA 3 You have added or confirmed that all E-Stop locations are on the Site Diagram 4 Do all E-Stops shutdown power to ALL DISPENSERS 5 Do all E-Stops shutdown power to ALL STP's 6 Are ALL E-Stops clearly Labeled 7 Are the TURBINE BREAKERS clearly identified / labeled POST TEST 8 All equipment secured and any access ports, lids, enclosures are closed. 9 All safety barricades and test equipment has been properly removed 10 E-Stop was reset and all dispensing functions are normal E-Stop Inspection Results 11 PASS FAIL INCONCLUSIVE Comments (Clearly describe any deficiencies found) WO: 3418303 Site Diagram (This site diagram is for reference only and is not drawn to scale) Work Order:3418303 Site ID / Name:32376 / 7-ELEVEN #32376, MKT 2368 Address:9600 BRIMHALL RD. City:BAKERSFIELD State:CA Zip:93312 W.O.# SC1-3418303 OVF W.O.# SC1-3418303 I10100 APR 23, 2014 12:05 PM 235431 7-11 32376 9600 BRIMHALL BAKERSFIELD,CA 93312 B0687875505001 SYSTEM STATUS REPORT ALL FUNCTIONS NORMAL I50301 APR 23, 2014 12:06 PM # 1:235431 7-11 32376 I50302 APR 23, 2014 12:06 PM # 2:9600 BRIMHALL I50303 APR 23, 2014 12:06 PM # 3:BAKERSFIELD,CA 93312 I50304 APR 23, 2014 12:06 PM # 4:B0687875505001 I51700 APR 23, 2014 12:06 PM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM I50F00 APR 23, 2014 12:06 PM MON DD YYYY HH:MM:SS xM I60100 APR 23, 2014 12:06 PM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 OFF 2 RUL ON 3 PUL ON 4 OFF I60200 APR 23, 2014 12:06 PM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 2 RUL 3 PUL 4 I60300 APR 23, 2014 12:06 PM TANK PRODUCT CODE TANK PRODUCT LABEL 1 1 2 RUL 2 3 PUL 3 4 4 I60400 APR 23, 2014 12:06 PM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 0 2 RUL 10028 3 PUL 10028 4 0 I60700 APR 23, 2014 12:06 PM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 0.00 2 RUL 96.00 3 PUL 96.00 4 0.00 I60900 APR 23, 2014 12:06 PM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 0.000000 2 RUL 0.000700 3 PUL 0.000700 4 0.000000 I61200 APR 23, 2014 12:06 PM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 NONE NONE 2 RUL NONE NONE 3 PUL NONE NONE 4 NONE NONE I62100 APR 23, 2014 12:06 PM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 0 2 RUL 900 3 PUL 769 4 0 I62200 APR 23, 2014 12:06 PM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 0 2 RUL 9526 3 PUL 9526 4 0 I62300 APR 23, 2014 12:06 PM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 0 2 RUL 9025 3 PUL 9025 4 0 I62400 APR 23, 2014 12:06 PM 2 RUL 1.5 3 PUL 1.5 I62800 APR 23, 2014 12:06 PM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 0 2 RUL 10028 3 PUL 10028 4 0 I62900 APR 23, 2014 12:06 PM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 0 2 RUL 1504 3 PUL 1504 4 0 I70300 APR 23, 2014 12:06 PM LIQUID TYPE SENSOR LOCATION TYPE 1 RUL STP SUMP DUAL FLT. HIGH VAPOR 2 RUL ANNULAR TRI-STATE (SINGLE FLOAT) 3 PUL STP SUMP DUAL FLT. HIGH VAPOR 4 PUL ANNULAR TRI-STATE (SINGLE FLOAT) 5 TRI-STATE (SINGLE FLOAT) 6 TRI-STATE (SINGLE FLOAT) 7 DISP 1-2 DUAL FLT. HIGH VAPOR 8 DISP 3-4 DUAL FLT. DISCRIMINATING 9 DISP 5-6 DUAL FLT. DISCRIMINATING 10 DISP 7-8 DUAL FLT. DISCRIMINATING 11 DISP 9-10 DUAL FLT. DISCRIMINATING 12 DISP 11-12 DUAL FLT. DISCRIMINATING 13 87 FILL SUMP TRI-STATE (SINGLE FLOAT) 14 91 FILL SUMP TRI-STATE (SINGLE FLOAT) 15 TRI-STATE (SINGLE FLOAT) 16 TRI-STATE (SINGLE FLOAT) I90200 APR 23, 2014 12:06 PM SOFTWARE REVISION LEVEL VERSION 329.02 SOFTWARE# 346329-100-C CREATED - 09.07.01.16.29 S-MODULE# 330160-106-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS CSLD BIR ISD I20600 APR 23, 2014 12:07 PM 235431 7-11 32376 9600 BRIMHALL BAKERSFIELD,CA 93312 B0687875505001 TANK ALARM HISTORY TANK 2 RUL HIGH WATER ALARM APR 23, 2014 10:48 AM APR 30, 2013 10:43 AM NOV 14, 2012 3:36 PM OVERFILL ALARM APR 23, 2014 10:41 AM APR 23, 2014 10:35 AM MAR 9, 2014 8:44 AM LOW PRODUCT ALARM APR 23, 2014 10:31 AM APR 5, 2014 1:31 PM APR 2, 2014 5:36 PM HIGH PRODUCT ALARM APR 23, 2014 10:41 AM APR 23, 2014 10:35 AM APR 30, 2013 10:33 AM INVALID FUEL LEVEL APR 23, 2014 10:32 AM APR 30, 2013 10:51 AM APR 30, 2013 10:29 AM PROBE OUT APR 23, 2014 10:58 AM APR 23, 2014 10:31 AM APR 30, 2013 10:51 AM HIGH WATER WARNING APR 23, 2014 10:48 AM APR 30, 2013 10:43 AM NOV 14, 2012 3:36 PM DELIVERY NEEDED APR 23, 2014 10:31 AM APR 9, 2014 5:21 PM APR 5, 2014 10:52 AM MAX PRODUCT ALARM APR 23, 2014 10:41 AM APR 30, 2013 10:34 AM NOV 14, 2012 3:29 PM LOW TEMP WARNING APR 23, 2014 10:58 AM APR 23, 2014 10:32 AM NOV 14, 2012 3:38 PM TANK 3 PUL HIGH WATER ALARM APR 23, 2014 10:46 AM APR 30, 2013 10:40 AM NOV 15, 2012 10:08 AM OVERFILL ALARM APR 23, 2014 10:37 AM APR 30, 2013 10:31 AM NOV 14, 2012 3:27 PM LOW PRODUCT ALARM APR 23, 2014 10:31 AM APR 2, 2014 5:24 PM APR 30, 2013 10:29 AM HIGH PRODUCT ALARM APR 23, 2014 10:37 AM APR 30, 2013 10:33 AM APR 30, 2013 10:31 AM INVALID FUEL LEVEL APR 23, 2014 10:59 AM APR 23, 2014 10:30 AM APR 30, 2013 11:30 AM PROBE OUT APR 23, 2014 10:59 AM APR 23, 2014 10:29 AM APR 30, 2013 11:27 AM HIGH WATER WARNING APR 23, 2014 10:46 AM APR 30, 2013 10:40 AM NOV 15, 2012 10:08 AM DELIVERY NEEDED APR 23, 2014 10:29 AM APR 9, 2014 3:19 PM APR 1, 2014 5:08 PM MAX PRODUCT ALARM APR 23, 2014 10:37 AM APR 30, 2013 10:33 AM NOV 14, 2012 3:27 PM LOW TEMP WARNING APR 23, 2014 11:00 AM APR 30, 2013 10:29 AM NOV 15, 2012 11:47 AM I30200 APR 23, 2014 12:07 PM 235431 7-11 32376 9600 BRIMHALL BAKERSFIELD,CA 93312 B0687875505001 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 RUL STP SUMP APR 23, 2014 9:26 AM SENSOR OUT ALARM APR 23, 2014 9:21 AM FUEL ALARM APR 30, 2013 9:46 AM SENSOR OUT ALARM 2 RUL ANNULAR APR 23, 2014 9:26 AM SENSOR OUT ALARM APR 23, 2014 9:20 AM FUEL ALARM OCT 17, 2013 10:19 AM FUEL ALARM 3 PUL STP SUMP APR 23, 2014 9:26 AM SENSOR OUT ALARM APR 23, 2014 9:16 AM LIQUID WARNING APR 30, 2013 9:46 AM SENSOR OUT ALARM 4 PUL ANNULAR APR 23, 2014 9:26 AM SENSOR OUT ALARM APR 23, 2014 9:17 AM FUEL ALARM APR 30, 2013 9:46 AM SENSOR OUT ALARM 7 DISP 1-2 APR 23, 2014 9:26 AM SENSOR OUT ALARM APR 23, 2014 9:25 AM LIQUID WARNING APR 30, 2013 9:46 AM SENSOR OUT ALARM 8 DISP 3-4 APR 23, 2014 9:26 AM SENSOR OUT ALARM APR 23, 2014 9:24 AM LIQUID WARNING APR 30, 2013 9:46 AM SENSOR OUT ALARM 9 DISP 5-6 APR 23, 2014 9:26 AM SENSOR OUT ALARM APR 23, 2014 9:23 AM LIQUID WARNING APR 30, 2013 9:46 AM SENSOR OUT ALARM 10 DISP 7-8 APR 23, 2014 9:26 AM SENSOR OUT ALARM APR 23, 2014 9:23 AM LIQUID WARNING APR 30, 2013 9:46 AM SENSOR OUT ALARM 11 DISP 9-10 APR 23, 2014 9:26 AM SENSOR OUT ALARM APR 23, 2014 9:22 AM LIQUID WARNING APR 30, 2013 9:46 AM SENSOR OUT ALARM 12 DISP 11-12 APR 23, 2014 9:26 AM SENSOR OUT ALARM APR 23, 2014 9:22 AM LIQUID WARNING APR 30, 2013 9:46 AM SENSOR OUT ALARM 13 87 FILL SUMP APR 23, 2014 9:26 AM SENSOR OUT ALARM APR 23, 2014 9:18 AM FUEL ALARM APR 30, 2013 9:46 AM SENSOR OUT ALARM 14 91 FILL SUMP APR 23, 2014 9:26 AM SENSOR OUT ALARM APR 23, 2014 9:13 AM FUEL ALARM APR 30, 2013 9:46 AM SENSOR OUT ALARM I10100 APR 23, 2014 12:08 PM 235431 7-11 32376 9600 BRIMHALL BAKERSFIELD,CA 93312 B0687875505001 SYSTEM STATUS REPORT ALL FUNCTIONS NORMAL