Loading...
HomeMy WebLinkAbout2014 REPAIR RESULTSSWRCB. January 2002 Page_of_ Secondary Containment Testing Report Form 71lis.form is intended.for use hy contractors pe1forming periodic testing of USTsecondm:J' containment systems. Use the appropriate pages of thisfonn to report results for all components tested. The completedform, wrillen test procedures, and printoutsfrom tests (if applicable). should he prm•ided to the facility mvnerloperatorfor submit/alto the local regulat01:1' agency. 1. FACILITY INFORMATION T Date ofTesting: -Facility Name: #5562 Fastrip 116 5/23/2014 Facility Address: 1640 South Chester Avenue. Bakersfield. CA 93304 Facility Contact: Omero Garcia I Phone: 661-393-7000 Date Local Agency Was Notified ofTesting: 5/12/2014 Name of Local Agency fnspector (if present during testing): 2. TESTING CONTRACTOR INFORMATION Company Name: Confidence UST Services Technician Conducting Test: Bryan A Self Credentials: x CSLB Licensed Contractor x SWRCB Licensed Tank Tester License Type: CSLB I License Number:804904 TT//11-1756 Manufacturer Training Manufacturer Comeonent(s) Date Training Expires UST I 0/21/2015 I nstallaton!Retro fit UST Service ICC l-28-2015 technician Star. Smith. Fibercast Fiber Glass Systems N.A. Franklin Fueling ---········- Sump Testing Ts-sts 08/22/2015 3. SUMMARY OF TEST RESULTS Component Pass Fail Not Repairs Component Pass Fail :-.lot Repairs Tested Made Tested Made 87 East Secondary X UDC 7-8 X . -87 West Secondary X l J -, UDC Transition North X ~, I . ' -91 Secondary X , , , UDC Transition South X [ 1 ' I> ., Diesel Secondary X [ 1 [ 1 [] '1 1 l 1 Siphon Secondary X I 1 [ 1 [ 1 -[ 1 [ 1 ( -87 East STP X L 1 ll [J r 1 II I I [1 ---87 West STP X _Q_ r 1 n r 1 ll l n 91 STP X II r 1 [J r 1 rJ L I Diesel STP X l ; Ll r 1 II [ r: u UDC 1-2 X f I I I ~ J lJ I [1 -UDC 3-4 X l 1 [ [] [ I J r . UDC 5-6 X r. r "1 [I [ J c: If hydrostatic testing was performed. describe what was done with the water after completion of tests: CERTIFICATION OF TECHNICIAN RESPONSIBI.J<= FOR CONDUCTING TillS TESTING To tire best of my knowledge, tlreJiu:ts stated in tlris document are ac&/1rate and in full compliance with legal requirement.\· Technician's Signature: 76// 7 e ~ -vAl" -Date: 5123/2014 SWRCB, January 2002 Page __ of __ 4. TANK ANNULAR TESTING Test Method Developed By: Tank Manufacturer x Industry Standard !l Professional Engineer Other (5'pec(f.i') Test Method Used: f 1 Pressure x Vacuum llydrostatic r Other (Spec((r) Test Equipment Used: Calibrated Gages Equipment Rcsolution:0.0625" :~;~: ~:-ht·.:~;~ ;:-:-·_ '' '~-f>;:·:.· ~ ·- Tank# Tank# Tank# Tank# -Is Tank Exempt From Testing?1 Yes No Yes No Yes No Yes No Tank Capacity: Tank Material: Tank Manufacturer: Product Stored: Wait time between applying pressure/vacuum/water and starting test: Test Start Time: Initial Reading {R1): Test End Time: final Reading(~): Test Duration: Change in Reading (~-R1): Pass/Fail Tiueshold or Criteria: Test Result: 0 Pass 0 FaiJ 0 Pass OFaiJ 0 Pass 0 FaiJ 0 Pass 0 Fail Was sensor removed for testing? Yes No NA Yes No L NA · Yes No NA Yes No Was sensor properly replaced and Yes No NA Yes No NA Yes No NA Yes No verified functional after testing? Comments -(include information 011 repairs made prior to testing, and recommended folloll'-up for failed /ests) 1 Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary containment, such as systems that are hydrostatically monitored or under constant vacuum, arc exempt from periodic containment testing. {California Code of Regulations, Title 23, Section 2637(a)(6)} NA NA SWRCB, January 2002 Page_ of_ 5. SECONDARY PIPE TESTING Test Method Developed By: U Piping Manufacturer x Industry Standard lJ Professional Engineer t-Test Method Used: Other (Specify) x Pressure Vacuum -Hydrostatic t-n Otller (Spec[fy) Test Equipment Used: Calibrated Gages Equipment Resolution:0.0625" ~f;:~*~·;:~r ·-:-.::-' .. ,-:.~'.~,.-<'·, ,~· Piping Run # 87 East Piping Run #87 West Piping Run# 91 Piping Run # Diesel ~ Piping Material: FRP FRP FRP FRP Piping Manufacrurer: Smith Smith Smith Smith Piping Diameter: 3.00" 3.00" 3.00" 3.00'' 1---Length of Piping Run: 100' 100' 100' 100' Product Stored: 87 87 91 Diesel -Method and location of piping-run isolation: Test Boot Test Boot Test Boot Test Boot Wait time between applying pressure/vacuum/water and 5 min 5 min 5 min 5 min starting test: -Test Start Time: !0:30am !0:30am I 0:30am !0:30am Initial Reading {R1): 5.00" psi 5.00" psi 5.00" psi 5.00" psi --Test End Time: !1:30am II :30am !1:30am !1:30am Final Reading(~): 1--- 5.00" psi 5.00" psi 5.00" psi 5.00" psi Test Duration: l hour I hour I hour I hour Change in Reading {R1.-R1): 0.00" 0.00" 0.00" 0.00" Pass/Fail 'll1reshold or 0.00" 0.00" 0.00" 0.00" Criteria: Test Result: X Pass 0 Fail X Pass 0 Fail X Pass OFail X Pass 0 Fail - Comments -(include il!{ormation on repairs made prior to testing, and recommended.follow-up.for.failed tests) SWRCB, January 2002 Page of 5.SECONDARY PIPE TESTING Test Method Developed By: ll Piping Manufacturer x Industry Standard f l Professional Engineer Other (Spec[fy) Test Method Used: x Pressure ll Vacuum I llydrostatic Other (Spec(M Test Equipment Used: Calibrated Gages Equipment Resolution:0.0625" ~~~~li"' .::;·····.ftl!r-; .. . . -. --tl.... . .,, ,(~·v~:/1[,·,-,, '1jj."<'., ... : P1pmg Run# S1phon Piping Run# Piping Run# Piping Run # Piping Material: FRP Piping Manufacturer: Smith Piping Diameter: 3.00" Length ofPiping Run: 100' Product Stored: 87 -Method and location of Test Boot piping-run isolation: Wait time between applying pressure/vacuum/water and 5 min starting test: --Test Start Time: I 0:30am --Initial Reading (R1): 5.00" psi Test End Time: I 1:30am -Final Reading(~): 5.00" psi Test Duration: I hour Change in Reading (~-R1): 0.00" Pass/Fail "Threshold or 0.00" Criteria: Test Result: X Pass 0 Fail OPass 0 Fail OPass 0 Fail OPass 0 Fail --··--------------·····--···--- Comments-(include infonnation on repairs made prior to testing. and recommended fo!loii'-UfJ for failed tests) SWRCB, January 2002 Page_ of 6. PIPING SUMP TESTING Test Method Developed By: ~Sump Manufacturer x Industry Standard C Professional Engineer I-- Other (Specify) Test Method Used: Pressure Vacuum x Hydrostatic n Other (Spec[fy) Test Equipment Used: Ts-sts Equipment Resolution: .. ~ ~ ... '· •.: : . ~ .. ~::.t\~'-~ -~-~~~~ .. : '4{ ' ~ ... Sump # 87 East Sump # 87 West Sump# 91 Sump # Diesel Sump Diameter: 39.00" 39.00" 39.00" 39.00" Sump Depth: 46.00" 46.00" 46.00" 47.00" 1---·- Sump Material: FRP FRP FRP FRP Height from Tank Top to Top of 16.00" 16.00" 12.00" 12.00" Highest Piping Penetration: Height from Tank Top to Lowest 12.00" 12.00" 12.00" 12.00" Electrical Penetration: - Condition of sump prior to testing: Clean & Dry Clean& Dry Clean & Dry Clean& Dry I--- Portion ofSump Tested' Pipe Penetration Pipe Penetration Pipe Penetration Pipe Penetration Does turbine shut down when sump sensor detects liquid (both product and water)/ CJYes IINo XNA UYcs I INo XNA Yes UNo XNA I I Yes nNo X NA Turbine shutdown response time NA NA NA NA -Is system programmed for fail-safe shutdown?' Yes No XNA Yes No XNA Yes No XNA Yes No XNA -Was fail-safe verified to be operational?' nYes No XNA Yes IJNo XNA I I Yes No XNA I Yes flNo X NA Wait time between applying pressure/vacuum/water and starting 5 min. 5 min. 5 min. 5 min. test: Test Start Time: -Initial Reading (R1): Test End Time: ~--· .. •1'\ .. 1 ~--.... I"'\ II. I Final Reading (RF): "''-''-' I I __ ... V~~ II I ''-'1,. -.IL -_._._ Test Duration: n.t::::t ~I L:::t f'{es uns Change in Reading (~-R1): Pass/Fail Threshold or Criteria: Test Result: X Pass 0 Fail X Pass 0 Fail X Pass 0 Fail X Pass 0 Fail Was sensor removed for testing? X Yes I lNo DNA X Yes II No ""'NA X Yes nNo DNA X Yes DNo lNA Was sensor properly replaced and XYes llNo nNA X Yes No UNA X Yes No ....,NA XYes ~No INA verified functional after testing? Comments -(include il!{ormation on repair.\ made prior to testing. and recommended.folloll'-up .for.failed test.\) 1 If the entire depth of the sump is not tested, specify how much was tested. If the answer to 1!!lY of the questions indicated with an asterisk (*) is "NO" or "NA ". the entire sump must be tested. (See SWRCB LG-160) SWRCB, January 2002 Page_ of _ 7. UNDER-DISPENSER CONTAINMENT (UDC) TESTING Test Method Developed By: r UDC Manufacturer x Industry Standard ~ Professional Engineer f-- Other (Specifi~ Test Method Used: r Pressure Vacuum x Hydrostatic Other (Spec{[v) Test Equipment Used: Ts-sts Equipment Resolution: ··: ~~ ~· J ,< .. ;:-~.; .. . ·'.. ,.;: . ~~ ..... · '; '' UDC # 1-2 uoc # 3-4 UOC # S-6 uoc # 7-8 UDC Manufacturer: Western Western Western Western -UDC Material: FRP FRP FRP FRP -UDC Depth: 33.00" 33.00" 33.00" 33.00" ·-Height from UDC Bottom to Top 9.00" 10.00" 9.00" 7.00" of llighcst Piping Penetration: --Height from UDC Bottom to 13.00" 15.00" 13.00" 12.00" Lowest Electrical Penetration: --Condition ofUDC prior to Clean & Dry Clean & Dry Clean & Dry Clean & Dry testing: -Portion of UDC Tested Pipe Penetration Pipe Penetration Pipe Penetration Pipe Penetration Does turbine shut down when UDC sensor detects liquid (both product and water)?' DYes IINo XNA Yes ! No X NA Yes !No XNA [I Yes 0 No X Nl\ Turbine shutdown response time N.A. N.A. N.A. N.A. 1---. Is system programmed for fatl-I Yes No XNA Yes No XNA Yes No XNA Yes No XNA safe shutdown?' Was fail-safe verified to be ~Yes No XNA []Yes II No X NA l Yes II No XNA Yes J No XNA operational?' Wait time between applying 5 Min 5 Min 5 Min 5 Min pressure/vacuum/water and starting test Test Start Time: Initial Reading (R1): Test End Time: ~AA II ~r.nN see-m ICON Final Reading (RF): -IJL n-.-..... _ Test Duration: l't:~ UIL:::» -·~~~ ..... ~ Chanse in Reading (R1-R1): - Pass/Fail TI1reshold or Criteria: Test Result: X Pass OFail X Pass OFail X Pass 0 Fail X Pass 0 Fail Was sensor removed for testing? '"Yes No X Nl\ Yes No XNA Yes No XNA Yes No XNA Was sensor properly replaced and 0 Yes II No XNA ~ Yes No XNA l Yes No XNA Yes n No X NA verified functional atlt:r testing? Comments-(include information on repairs made prior to testing, and recommended follow-up forfailed test.\) 1 lftllC entire depth of the UDC is not tested, specify how much was tested. If tile answer to ill!Y of the questions indicated with an asterisk(*) is "NO" or "N/\", the entire UDC must be tested. (See SWRCB LG-160) SWRCB. January 2002 Page __ of __ ?.UNDER-DISPENSER CONTAINMENT (UDC) TESTING ,...---, Test Method Developed By: , UDC Manufacturer x Industry Standard Professional Engineer t-Test Method Used: Other (Speci/)~ ~ Pressure Vacuum x Hydrostatic Other (Spec{fy) Test Equipment Used: Ts-sts Equipment Resolution: ~~~C\;t:;;i ;,_.. . : : . :' ·~:.-... ,.. .,-"······ UOC# Trans North UDC# Trans South UDC# UOC# UDC Manufacturer: Western Western UDC Material: fRP fRP UDC Depth: 33.00" 33.00" Height !Tom UDC Bottom to Top 9.00" 9.00" ofllighcst Piping Penetration: Height !Tom UDC Bottom to 13.00" 13.00" Lowest Electrical Penetration: Condition ofUDC prior to Clean & Dry Clean & Dry testing: Portion ofUDC Tested' Pipe Penetration Pipe Penetration Docs turbine shut down when UDC sensor detects liquid (both ~ct and water)?• DYes No XNA LJ Y cs 11 No X NA lJYes UNo UNA Yes ··No INA Turbine shutdown response time N.A. N.A. Is system programmed for fail- safe shutdown?· ~Yes No XNA Yes No XNA Yes No INA Yes No NA -Was fail-safe verified to be operational?' -Yes No XNA r Yes No XNA Yes No _NA Yes !No NA Wait time between applying 5 Min 5 Min pressure/vacuum/water and starting test Test Start Time: Initial Reading (R1): -... __ ... Test End Time: "'~~ ··~ lvVI,. Final Reading (RF): ~A~I I tit~ Test Duration: . - Change in Reading (R1-R1): Pass/fail Titreshold or Criteria: Test Result: X Pass OFail X Pass 0 Fail 0 Pass OFail 0 Pass OFail Was sensor removed for testing? 'l Yes No XNA Yes No XNA Yes No NA Yes No NA 1---Was sensor properly replaced and J Yes 1No XNA 0 Yes No XNA Yes No NA rlYcs lNo JNA verified flmctional after testing? Comments -(include information on repairs made prior to testing, and recommended follow-up for failed test.\) 1 If the entire depth of the UDC is not tested. specifY how much was tested. If the answer to any of the questions indicated with an asterisk (*) is "NO" or "NA ". the entire UDC must be tested. (See SWRCB LG-160) --·- I I ! ' SWRCB, January 2002 Page_ of 8. FILL RISER CONTAINMENT SUMP TESTING Facility is Not Equipped With Fill Riser Containment Sumps X Fill Riser Containment Sumps are Present. but were Not Tested -Test Method Developed By: 'l Sump Manufacturer Industry Standard :J Professional Engineer 'l Other (5/Jec{fy) - Test Method Used: [ Pressure I I Vacuum :-llydrostatic n Other (Specify) Test Equipment Used: Equipment Resolution: .,,:, ) .. ·-FiJI Sump # Fill Sump# Fill Sump# Fill Sump# Sump Diameter: 1-=-Sump Depth: Height fi-om Tank Top to Top of r-!:!ighcst PiEing Penetration: • Height fi-om Tank Top to Lowest Electrical Penetration: Condition of sump prior to testing: Portion of Sump Tested Sump Material: Wait time between applying pressure/vacuum/water and starting test: Test Start Time: Initial Reading (R1}: Test End Time: Final Reading (RF): r:r-o . est urat10n: Change in Reading {R1-R1}: Pass/Fail Threshold or Criteria: Test Result: 0 Pass OFail 0 Pass 0 Fail 0 Pass 0 Fail 0 Pass OFail Is there a sensor in the sump? -rl Yes II No I Yes "No Yes [)No l Yes No -Docs the sensor alarm when either product or water is [J Yes L No nNA LJYes No UNA liVes IJNo NA Yes ~No NA detected? Was sensor removed for testing? ~Yes I No rNA ·-Yes No 'NA Yes No NJ\ Yes No NA Was sensor properly replaced and DYes No NA Yes No :JNA Yes No NA Yes No NA verified functional aflcr testing? -- Comments -(include il!formation on repairs made prior to testing, and recommended.follow-up forfai/ed tests) ~~------ 4 5562 FASTRIP 1640 S OESTER AVE BAKERSFIELD CA 93304 05/23/2014 9:59 AH tu.R/1 REPIJlT 05/22/2014 7:09 PH 110 PROBE ~TECTED stiiP !.'\), 3 05/22/2014 7:09 PH 110 PROOE [ETECTE.il sti'.P 10. 2 05/22/2014 7:09 PH lfJ 0ROBE DETECTED SlW 10, 1 . 5562 FASTRIP 1640 S O£STER AVE IW<ERSFIELD CA 93304 05/23/2014 10:38 AH SUrtP lEVEL REPOOT SlJIIP 81E STP SlJIIP 91 STP SUrtP OS STP 4. 475 Ill 3. 799 Ill 5. 623 Ill ..... ·~I 5562 FASTRIP 1640 S O!ESTER AVE l!f,KERSFIElD CA 93304 05/23/2014 10:54 AH SUIIP LEAK TEST REPORT 87E STP TEST STARTED 10:39 AH TEST STARTED 05/23/2014 BEGIII LEVEL 4,4759 Ill Ell!l TillE 10:54 AH EliD DATE 05/23/2014 EliD LEVEL 4, 4738 Ill LEAK TI!RESH!l.D 0, 002 Ill TEST RESlJI. T FAILED 91 STP TEST STAATED 10:39 AH TEST STARTED 05/23/2014 BEG Ill lEVEL 3.79811 Ill EIID TIHE 10:54 AH EIO DATE 05/23/2014 EID LEVEL 3. 7978 Ill LEAK TlflES!IlLD O. 002 Ill TEST RESI1. T PASSED OS SlP TEST STAATEO 10:39 AH TEST STARTED 05/23/2014 BEG! II LEVEL 5.6225 Ill Ellll TIHE 10:54 AH Elll DATE 05/23/2014 Elll LEVEL 5.6214 Ill l.£Al( THRESIWl 0, 002 Ill TEST RESULT PASSED '-~ -----· .. ---.·· --· 5562 FASTRIP 16<10 S O<:ESTER AVE BAKERSFIELD CA 93304 05/23/2014 11:11 All SUIP LEAK TEST Rfl'ORT 87E STP TEST STARTED 10:56 AH TEST STAATED 05/23/2014 BEGIIILEVB. 4.4740 Ill ElK! TlltE 11:11AII EliD DATE 05/23/2014 EliD LEVEL 4.4710 Ill LEAK Tlf!ESHOLD 0, 002 Ill TEST REStlT FAILED 91 STP TEST STARTED 10:56 AH TEST STARTED 05/23/2014 BEGIII LEVEL 3, 7989 Ill EIID TIHE 11:11 AH Elll DATE 05/23/2014 Ell! LEVEl 3.781J3 Ill LEAK TlflESilOLD O. 002 Ill TEST RESII. T FAILED OS STP TEST STARTED 10:56 AH TEST STAATED 05/23/2014 BEG Ill LEVEL 5.6215 Ill Elll TillE 11:11 All Elll DATE 05/23/2014 EllD LEVEL 5.6212 Ill LEAK THlESilOLD 0. 002 lfl TEST RESil.T PASSED 5562 FASTRIP 1640 S CHESTER AVE BAKERSFIElD CA 93304 (15/23/20 14 11:27 All StJlf> lEAK TEST REPORT 87E STP TEST STARTED 11:12 All TEST STARTED (15/23/2014 BEG Ill lEVa 4, 4701 Ill Elll TillE 11:21 AH Elll DATE 05/23/2014 EllD lEVa 4, 4688 Ill LEAK THRESHOLD 0. 002 Ill TEST REStll. T PASSED 91 STP TEST STARTED 11:12 HI TEST STARTED 05/23/2014 BEG Ill lEVEl 3. 784 7 Ill EIIO TIHE 11:27 All EID DATE 05/23/2014 EIO LEVEL 3. 7799 Ill lEAK TlflESHDLO 0, 002 Ill TEST RESILT FAILED OS SIP TEST STARTED 11:12 All TEST STARTED (15/23/20111 BEG II I lEVa 5, 6211 Ill EIIO TillE 11:27 AH EIIO DATE 05/23/2014 ao LEVa s. 6211 111 l£AK THRESID.O 0, 002 Ill TEST RESUI. T PASSED --·-···· -------, 5562 FASTRIP 16QO S OESTER AVE BAKERSFIElD CA 93304 05/23/2014 11:44 AH SUI1P lEAK TEST REP!:flT 81E STP TEST STARTED 11:28 All TEST STARTED 05/23/2014 BEGIIIlEVEl. 4,4681 Ill EIIO TillE 11:113 All EIID DATE 05/23/20111 EID LEVEL 0,4665 Ill LEAl( TlliESHttO 0, 002 Ill TEST RESll.T PASSEO 91 ~~.,_-,.. TEST STARTED 11:28 All TEST STARTED 05/23/2014 BEG Ill LEVEL 3, 1793 Ill E!O TIHE 11:43 All Elll DATE 05/23/2014 a.u Leva 3. ms 111 LEAK TAAESI«JLO 0, 002 Ill TEST RESULT FAILED OS STP TEST STARTED 11:28 AH TEST STARTED 05/23/2014 BEG Ill lEVEl 5, 6210 Ill EIO TillE 11:43 AH 810 DATE 05/23/2014 E1D lEVa 5. 6210 Ill I LEAK THRESHllO o. 002 Ill TEST REStLT PASSED 5562 FASTRIP 1640 S CHESTER AVE BAKERSFIELD CA 93304 05/23/2014 12:12 PH ALAR/I REPORT 05/23/2014 POVER 001111 05/23/2014 POWER lP 12:11 P/1 12:12 P/1 5562 FASTRIP : 1~0 S CHESTER AVE BAKERSFIELD Cl\ 93304 05/23/2014 12:12 PH SII'.P LEVEL REPIJU SUt1P 87\1 STP SUP UOC 1·2 SlW lKlC 3·4 5tH' TS II 3, 71l4 Ill 2. 874 Ill 4,525 Ill 4, 795 Ill \ '; \ 5562 FASTRIP 1640 S OlESTER AVE BAKERSFIELD CA 933011 05/23/20111 12:32 P/1 SIH' LEAK TEST ~T 87\1 STP TEST STAATED 12: l1 PH TEST STAAlED 05/23/20111 BEG Ill LEVa 3. 7408 Ill BID TillE 12:32 P/1 BID DATE 05/23/20111 Ellll LEVa 3, 7396 Ill LEH< Tli61X.D 0, 002 Ill TEST RESULT PASSED UDC 1·2 TEST STAAl EO 12: l1 PH TEST STAATED 05/23/20111 BEG Ill lEVa 2. 8740 Ill EJID TillE 12:32 P/1 BIO DATE 05/23/2014 EJID LEVEL 2. 8739 Ill LEAK TlilESHOLD 0, 002 Ill TEST RESULT PASSED uoc 3-4 TEST STAATED 12:11 PH TEST STAATED 05/23/2014 BEG !II LEVa 4, 5258 Ill Elll TII1E 12:32 PH EJil DATE 05/23/2014 Elll LEVEL 4, 5260 Ill lEAK TllRESilJt.D 0, 002 Ill TEST REStl. T PASSED TS II TEST STAAT ED 12:11 PM TEST STAATED 05/23/2014 BEGIII LEVEL II, 7953 Ill EJID TIHE 12:32 PH Elll DATE 05/23/2014 EJI) lEVa 4, 7952 Ul LEAK THRES!lOLD 0, 002 Ill lEST REStL T PASSED ~~; '\''! 5~62 ..FASTRI~. 161i0 S CHESTER-AVE-- BAKERSFIELD CA 933011 05/23/201/J 12:49 PM SIJlP lEAK TEST REPOOT 8711 STP TEST STAATED 12:311 PH TEST STAATED 05/23/20111 BEG Ill lEVEl 3. 7396 Ill Elll TillE 12:49 PH Elll DATE 05/23/20111 Ell! LEVEL 3, 73911 Ill mx llflESH!lo o. 002 111 TEST RESULT PASSED uoc 1·2 TEST STARTED 12:311 PH TEST STARTED 05/23/20111 BEGIIILEVEL 2.8741 Ill EllD TillE 12:49 PH BIO DATE 05/23/2014 EJIO LEVEL 2. 8737 Ill LEAK ~ESllli.O 0, 002 Ill TEST RESULT PASSED ooc 3·4 TEST STARTED 12:311 PH TEST STARTED 05/23/201/J BEGIII LEVEL 4, 5260 Ill Elll Til£ 12:119 PM BID DATE 05/23/201/J EIIO LEVEL 4, 5259 Ill LEAK lHRESHOLO 0, 002 Ill TEST RESUI.. T PASSED TS II TEST STARTED 12:311 Ptl TEST STARTED 05/23/2014 BEGJIILEVEL a, 7953 Ill EJ.D TillE 12:49 PH BID DATE 05/23/20111 EllO LEVEL a, 7920 Ill lEAK THRESHIJLD 0, 002 Ill TEST RESILT FAILED