Loading...
HomeMy WebLinkAbout5.1-12061 Record DrawingREVIEWED BY: TRAFFIC ENGINEER, CITY OF BAKERSFIELD REVIEWED BY: ASSISTANT PUBLIC WORKS DIRECTOR, CITY OF BAKERSFIELD APPROVED 1 0 PUBLIC WORKS DIRECTOR, CITY OF BAKERSFIELD RAUL M. ROJAS R.C.E. 39880 DATE tl) t I- DATE zo /3 DATE MATERIALS LIST ESTIMATED QUANTITIES FOR PLAN CHECK AND INSPECTION FEE CALCULATIONS. NOT TO BE USED FOR BIDDING PURPOSES. BENCHMARK U TOP OF' CONCRETE MONUMENT IN A LAMPHOLE AT THE SOUTHEAST CORNER OF SECTION 13- 30/26, BEING ABOUT 50 —FEET SOUTH OF THE RAILROAD TRACK ALONG THE CENTERLINE OF BUENA VISTA ROAD. ELEVATION = 354.13 THE BEARING OF N 0 E ALONG THE CENTERLINE OF BUENA VISTA ROAD AS SHOWN ON PARCEL MAP 11838 PHASE 2 RECORDED IN BOOK 57 OF PARCEL MAPS AT PAGE 169 IN THE OFFICE OF THE KERN COUNTY RECORDER WAS TAKEN AS THE BASIS OF BEARINGS SHOWN HEREON. VICINITY MAP NO SCALE LOCAL STREETS 491 L. F. 0.30' A. C. /0.40' A. B. MING AVENUE 6" CURB AND GUTTER 19089 L.F. w o 2W � 6,105 O SURVEY MONUMENT ENCASEMENT 2 EA. METRO STREET NAME SIGNS 2 w ZU) ~ 1 J Q � � WHITE LANE EA. Q I EA. z HP-- HIGH POINT W_ �.L. CA SAgRK °° 0 pR EVE 4 BBL T�pUSE PROJECT DRIVE Sl TE SOUTHERN PACIFIC � Q > CJ RAILROAD 0 � w -N- 0 PANAMA LANE J O VICINITY MAP NO SCALE LOCAL STREETS 491 L. F. 0.30' A. C. /0.40' A. B. 229342 S.F. 6" CURB AND GUTTER 19089 L.F. 4" THICK SIDEWALK 6,105 S.F. SURVEY MONUMENT ENCASEMENT 2 EA. METRO STREET NAME SIGNS 2 EA. TRAFFIC CONTROL SIGNS 1 EA. WHEEL CHAIR RAMPS 2 EA. DECORATIVE L.E.D. STREET LIGHTS I EA. SHEET No. INDEX M TITLE SHEET M DETAILS— GENERAL NOTES M CORPORATE COURT — PLAN AND PROFILE LEGEND CK) SHEET INDEX NUMBER BEGIN CURB RETURN DIRECTION OF DRAINAGE O CONCRETE MONUMENT -� EXISTING STREET NAME SIGN -C> DECORATIVE L.E.D. STREET LIGHT GCB #12 CATCH BASIN w /NUMBER -�- POVC— PROPOSED STREET NAME SIGN LEGEND CL— CENTERLINE DWY— DRIVEWAY FL— FLOWLINE BCR— BEGIN CURB RETURN ECR— END CURB RETURN PI— POINT OF INTERSECTION EC— END CURVE BC— BEGIN CURVE PIVC -- POINT OF INTERSECTION VERTICAL CURVE POVC— POINT ON VERTICAL CURVE BVC-- BEGIN VERTICAL CURVE EVC— END VERTICAL CURVE PRC— POINT OF REVERSE CURVATURE PCC— POINT OF COMPOUND CURVATURE POC— POINT ON CURVE GB— GRADE BREAK HP-- HIGH POINT .EcoK.D DRAWING UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA DIAL TOLL FREE 1- 800 -227 -8600 AT LEAST TWO DAYS BEFORE YOU DIG ERV RCE 33449 EXPe LATE SOUTHERN PACIFIC RAILROAD KEY MAP, SCALE: 7' =200' -N- U_ u- 0 0 o w co M ==. 0a.Z w0wu cr_ J N~—z w =- Czc.o0LLJmcI Lu wu��wZCo >� h- piL��q- J- �coC60 wX=�- 55--tmzm LZ 2 U0' UJ Qww:r�e_ 0 F-- F-- F- 0 2 W W W�o,z.i Q0 ws Q0X3: c _? c�z WZow QrYo w ciu. s0Z >-�w U<t U j I zz 0-� c!) 0 co) o �► o tL -� Luuj>- jo0z=co22 Caw WU)WLu -gip QF-- z4Zco)!C3pw co © 0,3: Q u,w z 25 0 z 0 9 w 9 z z Q W zo z= 0 O z co L U- I— co z � 0 w w ow co Lij zM,0w0oa-� t- (9cf)w =DzQQOp zamo(/)w= Lw. Q03 » _joco z wQ °u- 0 Lu > z°—°aa C13 co Z *m w 0 O u1 Z¢ � >- va F_ �_ 0 -F_0aw rE L.L. W 0 0 o ry M Z Z � Z co lo o o cr_ I V)z.®Lid Z jr 0 U V) LLJ F- (f) >- . . Z 0 � - � UJ "y�U� m � LI��:D < < W � 0 LLJ�-� LLB Q� Z� �w Ld w0(.) 00 0 <F_ _j w -2 Z w . � y < > m Lu U 0 0Z m C�-� -r wz Q' }-- 0 V) ■ ,W < L (_)_ - L- LL F— Ljj 0� 0� M C/o) 'C��Oi. �Z�� -� �WV)Lj 0 < 'C] O i-=- C'UY'' �� <,5 Z 3z r , /dry z ..._ 0 �--� — 4 I ft Ld 0 > D_ f_ LL. ® �.— V l iii ry (n 0 Z w Z >_, 0 F- Or- M Ld 00 U) Z -r Lli W < < ZOPt o o 0 W <p-wwwzwo CD n'LLj>- 00(n00 E7>-C Ld2:�W0LLJ F_:2 0 0 F_ 0 0 (.) cr_ a 'l _Uj Lo a <Ua 3-0C> �c CL < 0 V1 _c 0 > V) a �43 wc __c 0 a� V) c 0 L J r CD ..r.® m CS? U") . C) z 4.0 L r w cu M 0 x od < w w LU cD LLJ -q) � 06 z o Z cy) LAJ uu C-q C.0 C) (o 0 � o N ui 0 r-- 0 3 (f) I z Nt z o i U) F- > ll, w DATE N 8/13/2013 s PA JOB No. 12 -2642N c. 0) v SHEET E v Q E z N c N OF 3 SHEETS /;4 CL LL 0 �.. w ZJ;~' z W Z w U) co 0 w v U > w �.L. CL 0 XAEER 4 $'�• 00 w CL M > CJ U tsJ � r-- 0 3 (f) I z Nt z o i U) F- > ll, w DATE N 8/13/2013 s PA JOB No. 12 -2642N c. 0) v SHEET E v Q E z N c N OF 3 SHEETS /;4 GENERAL NOTES 1. ALL CONSTRUCTION SHALL CONFORM TO THIS PLAN, THE CALIFORNIA BUILDING CODE, CITY OF BAKERSFIELD ORDINANCE No. 4637, LATEST EDITION AND STANDARDS PERTAINING THERETO. THESE DOCUMENTS SHALL BE MADE A PART HEREOF. 2. ALL CONSTRUCTION WITHIN THE CITY RIGHT -OF -WAY OR CITY EASEMENTS SHALL BE IN ACCORDANCE WITH CITY OF BAKERSFIELD STANDARDS AND STATE OF CALIFORNIA, DEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATIONS DATED MAY 2006. THESE STANDARDS, DRAWINGS AND DETAILS SHALL BE CONSIDERED A PART OF THESE PLANS AND THE CONTRACTOR SHALL OBTAIN A COPY FOR HIS USE. 3. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL NECESSARY PERMITS BEFORE START OF CONSTRUCTION. AN OPEN STREET PERMIT SHALL BE OBTAINED FROM THE CITY OF BAKERSFIELD FOR ANY WORK TO BE PERFORMED IN THE EXISTING, ACCEPTED STREET RIGHT -OF -WAY. UNLESS SECURED BY A SUBDIVISION AGREEMENT, SECURITY BASED ON AN APPROVED ENGINEER'S ESTIMATE FOR THE WORK PERFORMED WITHIN THE STREET RIGHT -OF -WAY AND INSURANCE, AS REQUIRED, SHALL BE PROVIDED BY THE CONTRACTOR PRIOR TO ISSUANCE OF A PERMIT. 4, 24 HOUR NOTICE: PRIOR TO THE START OF ANY PHASE OF CONSTRUCTION, THE CITY CONSTRUCTION INSPECTION SECTION SHALL BE GIVEN AT LEAST 24 HOURS NOTICE. THE SECTION MAY BE NOTIFIED AT (661) 326 -3049. 5. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING DIMENSIONS, DATA AND MEASUREMENTS AT THE BUILDING SITE PRIOR TO CONSTRUCTION. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. PORTER & ASSOCIATES, INC. MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. 6, EXISTING UTILITY AND UNDERGROUND LINES HAVE BEEN SHOWN ON THIS PLAN ACCORDING TO AVAILABLE RECORDS. THE ENGINEER IS NOT RESPONSIBLE FOR POSSIBLE ERRORS OR OMISSIONS. THE CONTRACTOR IS RESPONSIBLE FOR VERIFICATION OF THE LOCATION AND DEPTH OF ALL UTILITIES PRIOR TO BEGINNING OF ANY WORK. UNDERGROUND SERVICE ALERT (U.S.A.: 1- 800 - 227 - 2600) SHALL BE CONTACTED AT LEAST TWO WORKING DAYS PRIOR TO ANY CONSTRUCTION OR EXCAVATION. 7. ANY EXISTING IMPROVEMENTS OR UTILITIES THAT ARE REMOVED, DAMAGED OR UNDERCUT BY CONTRACTOR'S OPERATIONS SHALL BE REPAIRED OR REPLACED AT THE CONTRACTOR'S EXPENSE, AS DIRECTED BY THE ENGINEER AND APPROVED BY THE GOVERNING AUTHORITY. 8. IF A PROBLEM OR CONFLICT SHOULD ARISE DURING THE COURSE OF THE PROJECT, IT IS THE RESPONSIBILITY OF THE OWNER OR THE CONTRACTOR TO NOTIFY THE ENGINEER IMMEDIATELY PRIOR TO ANY FURTHER WORK. 9. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, TOOLS, EQUIPMENT AND SUPERVISION NECESSARY FOR A COMPLETE AND FUNCTIONAL PRODUCT. 10. ALL WORK WHICH IS DEFECTIVE IN ITS CONSTRUCTION OR DEFICIENT IN ANY OF THE REQUIREMENTS OF THESE DRAWINGS AND SPECIFICATIONS SHALL BE REMEDIED, OR REMOVED AND REPLACED BY THE CONTRACTOR IN AN ACCEPTABLE MANNER, AND NO COMPENSATION WILL BE ALLOWED FOR SUCH CORRECTION. 11. IN THE EVENT CONSTRUCTION STAKING BASED ON THE CONSULTANT'S PLANS DRAWINGS OR OTHER DOCUMENTS IS ACCOMPLISHED BY ANYONE OTHER THAN THE CONSULTANT, THE OWNER OR CONTRACTOR SHALL NOTIFY THE BUILDING OFFICIAL IN WRITING AS TO THE CHANGE OF ENGINEER IN RESPONSIBLE CHARGE. 12. THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT; INCLUDING EROSION, SEDIMENTATION & DUST CONTROL PLAN AND STORM WATER POLLUTION PREVENTION PLAN IMPLEMENTATION AND THE SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS; AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER. 13, IF THE CONTRACTOR IS IN DOUBT AS TO THE MEANING OF ANY PART OF THE DRAWINGS AND SPECIFICATIONS OR FINDS DISCREPANCIES IN OR OMISSIONS FROM THE DRAWINGS, HE SHALL SUBMIT A WRITTEN REQUEST FOR AN INTERPRETATION OR A CORRECTION THEREOF PRIOR OR TO FILING HIS BID PRICE FOR THE PROJECT. 14, PORTER & ASSOCIATES, INC. WILL NOT BE RESPONSIBLE OR LIABLE FOR UNAUTHORIZED CHANGES TO OR USES OF THESE PLANS. ANY AND ALL CHANGES TO THESE PLANS MUST BE APPROVED IN WRITING BY PORTER & ASSOCIATES, INC. 15. NORMAL STAKING AND MARKING OF THE PROJECT WILL BE SUPPLIED ONLY ONCE., ALL ESTAKING OR REMARKING SHALL BE AT THE EXPENSE OF THE CONTRACTOR. COB STREET IMPROVEMENT NOTES 1. THE SUBDIVIDER, IF REQUIRED, SHALL OBTAIN GRADING APPROVAL AS REQUIRED BY CITY OF BAKERSFIELD ORDINANCE, PRIOR TO START OF ANY EARTHWORK. 2. ANY TRENCHING TO BE CONDUCTED WITHIN THIS PROJECT SHALL BE BACKFILLED AND COMPACTED PER CITY STANDARD DETAIL ST --22. 3. THE CONTRACTOR SHALL REMOVE OR RELOCATE ALL OBSTRUCTIONS WITHIN THE STREET RIGHT -OF -WAY AS DIRECTED BY THE CITY ENGINEER. 4. ALL STREETS HAVE BEEN DESIGNED USING A MINIMUM "R" VALUE AS STATED IN THE SOILS REPORT. SEE STRUCTURAL SECTIONS FOR EACH STREET FOR SPECIFIC INFORMATION. SHOULD FURTHER TESTING SHOW A LOWER "R" VALUE OF THE ACTUAL IN PLACE MATERIAL, STREETS SHALL BE REDESIGNED ACCORDING TO THE LOWER "R" VALUE, IN ACCORDANCE WITH CITY ENGINEER. 5. RELATIVE COMPACTION OF NOT LESS THAN 95% SHALL BE OBTAINED FOR A MINIMUM DEPTH (T) OF 1.1 FOOT BELOW FINISH GRADE ON LOCAL STREETS ( T =1.5' TO 2.5' AS DIRECTED BY THE PUBLIC WORKS DIRECTOR ON COLLECTOR AND ARTERIAL HIGHWAYS) FROM LIP OF GUTTER TO LIP OF GUTTER. IN ADDITION, RELATIVE COMPACTION OF NOT LESS THAN 90% SHALL BE OBTAINED FOR A MINIMUM DEPTH OF 0.5' FEET BELOW GRADING PLANE FOR THE ENTIRE WIDTH OF PAVEMENT (LIP OF GUTTER TO LIP OF GUTTER). 6. THE CONTRACTOR SHALL OBTAIN 90% RELATIVE COMPACTION UNDERNEATH THE SIDEWALK AND CURB AND GUTTER TO A DEPTH OF 6 ". THE LOCATION OF THE TESTS SHALL BE DETERMINED BY THE CITY. 7. COMPACTION TESTS SHALL BE THE RESPONSIBILITY OF THE DEVELOPER. THE NUMBER AND LOCATION OF REQUIRED TESTS SHALL BE DETERMINED BY THE CITY ENGINEER. THE COST OF RETESTING DUE TO FAILED COMPACTION TESTS WILL BE BACKCHARGED TO THE CONTRACTOR. g• ALL CONCRETE SHALL BE CLASS 3 AND SHALL CONTAIN A MINIMUM OF 505 LBS. /CU. YD. OF CEMENT AND HAVE A MAXIMUM WATER /CEMENT RATIO OF 0.50. 9. ASPHALT REJUVENATING AGENT SHALL BE APPLIED TO NEW ASPHALT CONCRETE PAVEMENT IN ACCORDANCE WITH THE PROVISIONS FOR FOG SEAL IN SECTION 37, BITUMINOUS SEALS, OF THE STATE DEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATIONS, CURRENT EDITION, AND THE STATE DEPARTMENT OF TRANSPORTATION STANDARD SPECIAL PROVISIONS CURRENTLY IN EFFECT, AS DIRECTED BY THE CITY ENGINEER. 10. NEW STREETS SHALL BE EXTENDED AT INTERSECTIONS AS DIRECTED BY THE PUBLIC WORKS DIRECTOR IN ORDER TO PROVIDE A TIE INTO EXISTING STREET PAVEMENT. 11. SEWER LATERAL LOCATIONS TO BE STAMPED (S) INTO THE CURB FACE OVER EACH LATERAL. 12. ELEVATIONS AND GRADES SHOWN ON THE PROFILES ARE GUTTER FLOW LINES (INVERTS). 13. THE CONTRACTOR SHALL INSTALL PERMANENT TRAFFIC CONTROL SIGNING AND OTHER SAFETY DEVICES (NOT SHOWN ON THESE PLANS) TO MEET WITH THE APPROVAL OF THE CITY PUBLIC WORKS DIRECTOR. THE PRICE FOR THIS ITEM SHALL BE INCLUDED IN THE PAVEMENT PRICE. 14. SIGN PANELS SHALL BE MOUNTED ON POSTS WITH HAWKINS M2G SERIES BOLT AND VANDAL PROOF NUT ASSEMBLY OR EQUAL, ROADSIDE SIGNS INSTALLED PER CITY STANDARD DETAIL T--19 SHALL BE LOCATED WITHIN SIDEWALK, 6" FROM BACK. 15. SEE WATER, STORM - DRAIN, AND SEWER IMPROVEMENT PLANS FOR OTHER IMPROVEMENTS THAT ARE A PART OF THIS PROJECT. COB ASPHALT CONCRETE PAWING MOTES 1- ASPHALT CONCRETE SHALL BE TYPE A (MODIFIED) FOR ALL ARTERIAL AND COLLECTOR STREETS AND TYPE B (MODIFIED) FOR LOCAL STREETS AND SHALL CONFORM TO THE PROVISIONS IN SECTION 39, "ASPHALT CONCRETE it OF THE CAL TRANS STANDARD SPECIFICATIONS AND THESE SPECIAL PROVISIONS. 2. PRIOR TO THE ADDITION OF ASPHALT BINDER, THE COMBINED MINERAL AGGREGATE FOR TYPE A (MODIFIED) OR TYPE B (MODIFIED) ASPHALT CONCRETE SHALL CONFORM TO THE REQUIREMENTS OF SECTION 39 -2.02 "AGGREGATE," OF THE STANDARD SPECIFICATIONS FOR 3/4" MAXIMUM, MEDIUM GRADING. 3. ASPHALT BINDER FOR TYPE A (MODIFIED) ASPHALT CONCRETE AND TYPE B (MODIFIED) ASPHALT CONCRETE SHALL BE PG 64 -10 PERFORMANCE GRADED ASPHALT, UNLESS OTHERWISE DIRECTED BY THE CITY ENGINEER. THE ASPHALT BINDER SHALL CONFORM TO THE REQUIREMENTS IN THE TABLE FOR PERFORMANCE GRADED ASPHALT BINDER, IN SECTION 92- 1.02(B), "GRADES," OF THE STANDARD SPECIFICATIONS. 4. THE AMOUNT OF ASPHALT BINDER TO BE MIXED WITH THE MINERAL AGGREGATE SHALL BE DETERMINED BY THE CONTRACTOR IN ACCORDANCE WITH CALIFORNIA TEST METHOD 367 USING SAMPLES OF MATERIALS PROPOSED FOR USE IN THE WORK. THE AMOUNT OF ASPHALT BINDER SHALL BE APPROVED BY THE CITY ENGINEER. 5. AT LEAST 14 DAYS PRIOR TO THE START OF WORK, THE CONTRACTOR SHALL SUBMIT THE FOLLOWING FOR THE CITY ENGINEER'S REVIEW AND APPROVAL: A. A LIST OF AGGREGATE AND ASPHALT SOURCES. B. DOCUMENTATION VERIFYING THAT THE AGGREGATES TO BE INCORPORATED IN THE WORK CONFORM TO THE REQUIREMENTS OF SECTION 39- 2.02, "AGGREGATE," OF THE STANDARD SPECIFICATIONS AND THESE SPECIAL PROVISIONS. MATERIAL SIEVE ANALYSIS AND SAND EQUIVALENT TEST RESULTS SHOULD NOT BE OLDER THAN SIX (6) MONTHS. ALL OTHER TEST RESULTS SHOULD NOT BE OLDER THAN ONE 1 YEAR. C. AN ASPHALT CONCRETE MIX DESIGN DETERMINED IN ACCORDANCE WITH CALIFORNIA TEST 367. LABORATORY TEST RESULTS ON WHICH THE DESIGN IS BASED SHALL BE SUBMITTED WITH THE MIX DESIGN ALONG WITH THE THEORETICAL MAXIMUM DENSITY OF THE DESIGN MIXTURE AS DETERMINED BY ASTM D2041. THE ASPHALT CONCRETE MIX SHALL MEET THE REQUIREMENTS OF SECTION 39 -2.02, "AGGREGATE," OF THE STANDARD SPECIFICATIONS AND THESE SPECIAL PROVISIONS. IF THE DATA SUBMITTED SHOWS THAT THE MATERIALS ARE SUBSTANTIALLY THE SAME AS WHEN THE DESIGN WAS PREPARED, THE DESIGN MAY BE UP TO THREE 3 () YEARS OLD. THE CONTRACTOR SHALL BEAR ALL COSTS ASSOCIATED WITH THE ASPHALT CONCRETE MIX DESIGN. 6. WHERE NEW ASPHALT CONCRETE PAVEMENT IS TO CONFORM TO EXISTING PAVED SURFACES, THE EXISTING PAVEMENT IS TO BE SAW CUT IN A NEAT STRAIGHT LINE, EITHER PARALLEL OR PERPENDICULAR TO THE CENTERLINE OF THE STREET, AND AT A MINIMUM DISTANCE OF ONE (1) FOOT FROM THE EXISTING EDGE OF PAVEMENT. 7. A PRIME COAT WILL NOT BE REQUIRED ON NON -PAVED AREAS TO BE SURFACED PRIOR TO THE PLACEMENT OF ASPHALT CONCRETE; HOWEVER, ALL OTHER REQUIREMENTS OF SECTION 39 -4.01, "SUBGRADE," OF THE STANDARD SPECIFICATIONS SHALL BE MET. 8. THE AREA TO WHICH PAINT BINDER HAS BEEN APPLIED SHALL BE CLOSED TO PUBLIC TRAFFIC. CARE SHALL BE TAKEN TO AVOID TRACKING BINDER MATERIAL ONTO THE EXISTING PAVEMENT SURFACE BEYOND THE LIMITS OF CONSTRUCTION. 9. PAVING JOINTS SHALL MATCH STRIPE LOCATIONS UNLESS OTHERWISE PERMITTED BY THE CITY ENGINEER. 10. INTERSECTIONS AND TAPERED SHOULDERS SHALL BE SURFACED AS DIRECTED BY THE CITY ENGINEER. ADDITIONAL ASPHALT CONCRETE SHALL BE PLACED AT ROAD? CONNECTIONS AND PRIVATE DRIVES, WHERE SHOWN ON THE PLANS AND AS DIRECTED BY THE CITY ENGINEER, AND HAND RAKED, IF NECESSARY, AND COMPACTED TO FORM SMOOTH, TAPERED CONNECTIONS. 11. WHERE THE COMPACTED THICKNESS OF A LAYER OF ASPHALT CONCRETE IS 0.15 FOOT OR LESS, PAVING OPERATIONS SHALL BE CONDUCTED IN SUCH A MANNER THAT, AT THE END OF EACH WORK SHIFT, THE LENGTH OF PAVEMENT ALONG THE LONGITUDINAL DROP -OFF BETWEEN ADJACENT LANES IS. NOT GREATER THAN THAT WHICH CAN BE SURFACED DURING THE FOLLOWING SHIFT OF NORMAL PAVING OPERATIONS. ADDITIONAL ASPHALT CONCRETE SHALL BE PLACED ALONG THE TRANSVERSE DROP -OFFS ON EACH LANE. SUCH ADDITIONAL ASPHALT CONCRETE SHALL BE HAND RAKED AND COMPACTED TO FORM TEMPORARY CONFORMS BEFORE THE LANES ARE OPENED TO PUBLIC TRAFFIC. KRAFT PAPER, OR OTHER APPROVED BOND BREAKER, E ER, MAY BE PLACED UNDER THE CONFORMS TO FACILITATE THE REMOVAL OF THE CONFORMS WHEN PAVING OPERATIONS RESUME. 12. WHERE THE COMPACTED THICKNESS OF A LAYER OF ASPHALT CONCRETE IS MORE THAN 0.15 FOOT, PAVING OPERATIONS SHALL BE CONDUCTED IN SUCH A MANNER THAT THE LAYER OF ASPHALT CONCRETE IS PLACED ON ALL CONTIGUOUS LANES OF THE TRAVELED WAY BEFORE THE LANES ARE OPENED TO PUBLIC TRAFFIC. AT THE END OF EACH WORK SHIFT, THE DISTANCE BETWEEN THE ENDS OF A LAYER OF ASPHALT CONCRETE ON ADJACENT LANES SHALL NOT BE GREATER THAN 10 FEET. ADDITIONAL ASPHALT CONCRETE SHALL BE PLACED ALONG THE TRANSVERSE DROP -OFFS ON EACH LANE AND ALONG THE LONGITUDINAL DROP -OFF BETWEEN ADJACENT LANES, SUCH ADDITIONAL ASPHALT CONCRETE SHALL BE HAND RAKED AND COMPACTED TO FORM TEMPORARY CONFORMS BEFORE THE LANES ARE OPENED TO PUBLIC TRAFFIC. KRAFT PAPER, OR OTHER APPROVED BOND BREAKER, MAY BE PLACED UNDER THE CONFORMS TO FACILITATE THE REMOVAL OF, THE CONFORMS WHEN PAVING OPERATIONS RESUME. 13. ASPHALT CONCRETE SHALL BE COMPACTED TO A MINIMUM 92 PERCENT OF THE MAXIMUM THEORETICAL DENSITY AS DETERMINED BY ASTM D -2041. IN- PLACE DENSITY SHALL BE DETERMINED IN ACCORDANCE WITH CALIFORNIA TEST 375. 14. IF THE IN -PLACE DENSITY OF ANY LOT OF ASPHALT CONCRETE IS LESS THAN 92 PERCENT OR GREATER THAN 94 PERCENT OF THE MAXIMUM THEORETICAL DENSITY, THE CONTRACTOR WILL BE ADVISED THAT THE REQUIRED RELATIVE COMPACTION IS NOT BEING ATTAINED AND THAT THE MATERIALS OR PROCEDURES OR BOTH, IF NEEDED, NEED ADJUSTMENT. ASPHALT CONCRETE SPREADING OPERATIONS SHALL NOT CONTINUE UNTIL THE CONTRACTOR HAS NOTIFIED THE CITY ENGINEER OF THE ADJUSTMENT THAT WILL BE MADE IN ORDER TO MEET THE REQUIRED COMPACTION, IF ANY SUCCESSIVE TEST AFTER NOTICE IS GIVEN DOES NOT MEET THE SPECIFIED RANGE, THE ASPHALT CONCRETE REPRESENTED BY THAT LOT SHALL BE REMOVED AND REPLACED WITH MATERIAL THAT MEETS THE IN -PLACE DENSITY REQUIREMENTS. 15. IF THE TEST RESULTS FOR ANY LOT OF ASPHALT CONCRETE INDICATE THAT THE RELATIVE COMPACTION IS EITHER LESS THAN 90% OR MORE THAN 96%, THE ASPHALT CONCRETE REPRESENTED BY THAT LOT SHALL BE REMOVED AND REPLACED WITH MATERIAL THAT DOES MEET THE IN -PLACE DENSITY REQUIREMENT. THE CORRECTIVE WORK SHALL BE AT THE CONTRACTOR'S EXPENSE. 16. THE FIELD DENSITY OF COMPACTED ASPHALT CONCRETE SHALL BE DETERMINED BY: A. A PROPERLY CALIBRATED NUCLEAR ASPHALT TESTING DEVICE IN THE FIELD, OR B. ASTM D1188 WHEN SLABS OR CORES ARE TAKEN FOR LABORATORY TESTING. ZINC STEARATE MAY BE SUBSTITUTED WITH PARAFFIN. C. IN CASE OF DISPUTE, METHOD "B" SHALL BE USED. 17. IF THE FINISHED SURFACE OF THE ASPHALT CONCRETE DOES NOT MEET THE SPECIFIED SURFACE TOLERANCES IT SHALL BE BROUGHT WITHIN TOLERANCE BY EITHER: (1) ABRASIVE GRINDING WITH EQUIPMENT UTILIZING DIAMOND BLADES, (2) REMOVAL AND REPLACEMENT, OR (3) PLACEMENT OF AN ASPHALT CONCRETE OVERLAY. THE METHOD WILL BE SELECTED BY THE CITY ENGINEER, THE CORRECTIVE WORK SHALL BE AT THE CONTRACTOR'S EXPENSE. 18. IF ABRASIVE GRINDING IS USED TO BRING THE FINISHED SURFACE TO SPECIFIED SURFACE TOLERANCES ADDITIONAL GRINDING SHALL BE PERFORMED, AS NECESSARY, TO ENLARGE THE GRINDING AREA SO THAT THE LONGITUDINAL LIMITS OF GRINDING ARE AT A CONSTANT OFFSET FROM, AND ARE PARALLEL TO, THE NEAREST LANE LINE OR PAVEMENT EDGE, AND THE TRANSVERSE LIMITS OF GRINDING ARE NORMAL TO THE PAVEMENT CENTERLINE. ALL GROUND AREAS SHALL BE NEAT RECTANGULAR AREAS OF UNIFORM SURFACE APPEARANCE. ABRASIVE GRINDING SHALL CONFORM TO THE REQUIREMENTS IN THE FIRST PARAGRAPH AND THE LAST FOUR PARAGRAPHS OF SECTION 42- 2.02, "CONSTRUCTION," OF THE STANDARD SPECIFICATIONS. A FOG SEAL COAT SHALL BE APPLIED TO ALL FINISHED ASPHALT SURFACES AT THE CONTRACTOR'S EXPENSE. THE FOG SEAL COAT SHALL BE EITHER .ASPHALT REJUVENATING AGENT OR ASPHALTIC EMULSION AS DIRECTED BY THE CITY ENGINEER. 19. BASE MATERIAL IN ALL CITY STREETS INCLUDING ARTERIAL, COLLECTOR, AND LOCAL ROADBEDS SHALL EITHER MEET THE SPECIFICATIONS FOR CLASS 2 AGGREGATE BASE (CL 2 AB) CONFORMING TO SECTION 26 OF THE CALTRANS STANDARD SPECIFICATIONS, LATEST EDITION, OR SHALL BE FINE GRADATION CRUSHED MISCELLANEOUS - BASE (CMB) CONFORMING TO SECTION 200 -2.4 OF THE "GREENBOOK" WHICH ALLOWS UP TO 50% OF THE VOLUME TO BE RECLAIMED ASPHALT CONCRETE, PORTLAND CEMENT CONCRETE, LEAN CONCRETE BASE, CEMENT TREATED BASE, OR A COMBINATION OF THOSE MATERIALS - OTHER RECYCLED BASES SHALL NOT BE ALLOWED. AGGREGATE BASE SHALL BE COMPACTED TO A MINIMUM OF 95% OF MAXIMUM DRY DENSITY, 20. THE PAVING CONTRACTOR SHALL GRADE THE PAVING AREAS TO THE FOLLOWING MODIFIED CALTRANS STANDARD SPECIFICATION SECTION 19 -1.03 PER THE CITY OF BAKERSFIELD: IMMEDIATELY PRIOR TO PLACING SUBSEQUENT LAYERS OF MATERIAL THEREON, THE GRADING PLANE SHALL CONFORM TO ONE OF THE FOLLOWING: A. WHEN ASPHALT CONCRETE OR ASPHALT CONCRETE BASE IS TO BE PLACED ON THE GRADING PLANE, THE GRADING PLANE AT ANY POINT SHALL NOT VARY MORE THAN 0.02 FOOT ABOVE OR BELOW THE GRADE ESTABLISHED BY THE ENGINEER. B. WHEN SUBBASE OR BASE MATERIAL (OTHER THAN ASPHALT CONCRETE BASE ) IS TO BE PLACED ON THE GRADING PLANE, THE GRADING PLANE AT ANY POINT SHALL NOT VARY MORE THAN 0,04 FOOT ABOVE OR BELOW THE GRADE ESTABLISHED BY THE ENGINEER. CITY STANDARD PL TES 1. THE FOLLOWING CITY OF BAKERSFIELD STANDARD DRAWINGS SHALL BE CONSIDERED A PART OF THESE PLANS. (CONTRACTOR TO OBTAIN LATEST EDITION, 10- 26 -89, UNLESS OTHERWISE NOTED) CITY STD. NO. DESCRIPTION CITY STD, NO. DESCRIPTION ST--1 CURB AND GUTTER (TYPE "A" "B" AND "C" � ) El -- ST 17 WIDE CROSS - -GUTTER [] -ST -2 COMMERCIAL DRIVEWAY - ST 18 �, „ s, �f „ MEDIAN CURBS (TYPE M M -1 AND M-2) ST--3 SIDEWALK ❑ _ ST 19 HANDICAP RAMPS ❑ ST -4 RESIDENCE DRIVEWAY ❑ _ ST 20 PRIVATE STREET GATES ❑ ST--5 HOUSE NUMBER FOR CURBS El - ST 21 REFUSE CONTAINER PAD El ST -6 PAVEMENT PATCHES 0 �. ST 22 TRENCH BACKFILL AND COMPACTION REQUIREMENTS r-1 ST-7 CROSS- GUTTERS El D -10 SIDEWALK UNDERDRAIN [] ST -8 26 INCH PART CIRCLE CULVERT ❑ D -11 DRAINAGE BASIN ST -9 STREET SPECIFICATIONS D -14 P$ ,$ CATCH- BASIN, TYPE A ST -10 STREET SECTIONS ❑ _ D 15 31 CATCH - BASIN, TYPE A-1 ay ❑ ST -1 OA STREET SECTIONS D---16 GUTTER DEPRESSIONS ST -11 STREET CROSS SECTIONS SW -4 MANHOLE, TYPE '� „ WITH DROP CONNECTION ❑ ST -12 ALLEY CROSS SECTION SW -5 FRAMES & COVER FOR MANHOLES & CLEANOUTS ST -13 SURVEY MONUMENT - T 1 STREET SIGN, POST TYPE ® ST -14 * *STREET LIGHT, MAST ARM TYPE ❑ T-- 3 MAJOR COLLECTOR TRANSITION ST--15 CUL -DE- -SACS [] - T 12 MINIMUM ACCESS DESIGN ST -16 STREET KNUCKLE El T -34 TRAFFIC SIGNAL INTERCONNECT - WIRING AND PULL BOXES * *FIBERGLASS STREET LIGHTS NOT ALLOWED CALTRANS STANDARD PLANS, �• THE FOLLOWING CALTRANS STANDARD PLANS SHALL BE CONSIDERED A PART OF THESE PLANS. (CONTRACTOR TO OBTAIN LATEST EDITION THEREOF) CALTRANS STD. PLAN 0 RSP A88A DESCRIPTION CURB RAMP DETAILS i ayf FREO . W, PORTER, DATE v a a,r,)O w0u� ���� tua�¢ �m wL "uj c� LL z =az ;0 �>� �C �0, 3z ;cnC/i2 w�� ;ems =gym w z Lu W�0�:c uj m cl) 0 I -- . U F_ W 12 zz � Uwz� Lu C0 LU z 0 0 �CjWo�- C W>022 =,u w Ir Q2 00 (Laoom a fLlJ0z%' =U -U� C0�W� CL o�z�?W�� z< �UJ0 m O t0W� -zU` LDLLI �� U. Lu a. Q< W M 0 m6< zap z 0L L P c_c, c >° a 7w- U t/3 Lt�l = � ul p 6 w 0 ctu - w LLI W w z cry a- � = =�c�3: W 00 0 N N cCQ z o Lu 0 C) ._._ Cil L0 .� o _ E W V� ...�. > T_ (0 w x LL �C U) CD oes UJ cy) Z z 4_0 Ce) w (.0 C) �oXAEE R c 0 4 mot- v- to L LJ > U 01 U N DATE 8/13/2013 N PA JOB No. 12 -2642N E SHEET 0 E i z i OF 3 SHEETS ui Q_ ILL CL w W 0 m Z w W LL C) W 0 U < > �oXAEE R c 0 4 mot- v- to L LJ > U 01 U N DATE 8/13/2013 N PA JOB No. 12 -2642N E SHEET 0 E i z i OF 3 SHEETS CONSTRUCTION NOTES a] 'CONSTRUCT 6" CURB & GUTTER PER C.O.B. STD. DWG. ST-1 02 CONSTRUCT 5.5' WIDE COMBINATION TYPE SIDEWALK PER C.O.B. STD. DWG. ST-3. ❑CONSTRUCT WHEELCHAIR RAMP PER CALTRANS REVISED STANDARD PLAN A88A CASE "A". 1-41 CONSTRUCT TYPE "A' CATCH BASIN PER C.O.B. STD. DWG. NO. D-14. INSTALL STREET NAME SIGN PER CITY STANDARDS. INSTALL TRAFFIC SIGN PER CITY STANDARDS. Rl -1 INSTALL Rl -1 STOP SIGN W/ STOP BAR. ALL PLAN VIEW STATIONING IS BASED ON CENTERLINE DATA UNLESS OTHERWISE NOTED. ALL PROFILE STATIONING IS BASED ON FLOWLINE DATA UNLESS OTHERWISE NOTED. ADJUST ALL EXISTING MANHOLES, CLEANOUTS9 VALVE COVERS, ETC. TO FINISHED GRADE PER CITY STANDARDS. FL FLOWLINE STATIONING F FL 8+92.35 0 0 3�LL Lo Lr, 04 C's (D 0 + -4 co 0( -i U-11; CONSTRUCT SURVEY MONUMENT ENCASEMENT PER C.O.B. STD. DWG. ST-13. _c> INSTALL DECORATIVE L.E.D. STREET LIGHT. CONTRACTOR SHALL COORDINATE APPROVAL WITH CITY OF BAKERSFIELD AND. OWNER. 0 EXISTING SURVEY MONUMENT - PROTECT IN PLACE. SEWER MANHOLE SEWER CLEAN OUT STORM DRAIN MANHOLE RIGHT-OF-WAY SEWER STORM DRAIN EXISTING EDGE OF PAVEMENT CONSTRUCT MIN. 0.30" TYPE "B" A.C. PAVING OVER MIN. 0.409 CRUSHED CLASS 11 AGGREGATE BASE OVER MIN. 1.00" NAT. GRD. COMPACTED TO 95% MAX. DENSITY 0 n r^ v-'w rL M, 3�`r U-) C-) v)w�'; m 00 MM • 0-00 N ro po 00 pr) C2 24.67 33.00 0; 00 + C3 45.10 + 352 ...... co ................... + 0 .............. 0 30.0� . U- ....... U- ................ _j ..................... 06 z w C) L_ 350:...:. :...:...:......... CL w 0 z CL 00- ow t 0 < ZZ 0 < ......................... CWL OW FX- W W w Ly i OL, ZLU 'z 0 oz czr) 0 G (o .......................... 348:...:...'.... ......................... .... _0728% 0- A %j Ee7o 2 ffiw,, zo Z LL- Lij w u- mcn > 0���a 04 AG -x.21% b% �, <:� C6 LLJ 0 0 a. x wo W> 0�_ ............................ Df S GV fZ 0#UNE Sl ....................... 9+00 10+00 11+00 YARIES R/W GRADE LINE SEE C.O.B. STD. DWG. ST-11 FOR SLOPE PARAMETERS 60�� SEDR�SEE I PM 119522 EE I OM ENT PLANS) 349 342 Z 0 0 0 W l °' C3 U-) 1 14+53.95 r- --w I F- z C4 z 9, 34' 34s ;SEE BOT DRIVE PM 11952�2 MPRO VEMENT SEE RIGHT FOR STRIPING MOD CATIONS PLANS) I �C�, ROAD B STA 45.10' ON CURVE w * N U w m 00 .00 • 42.00 0 Ic- 265040*01" C2 C/L ,3 t- L_ I- I- 111 i v it- v I %., I x STRUCTURAL SECTION 60' RIGHT-OF-WAY ION N.T.S. !wp� R/W 6" TYPE "B" CURB & GUTTER W/ 5.5 WIDE SIDEWALK COMPACT UNDER CURB, GUTTER AND SIDEWALK (TYP.) 6" MIN. TO 90% MAX. DENSITY. DATE CURVE TABLE CURVE I LENGTH RADIUS TANGENT DELTA Cl 194.74 42.00 0 Ic- 265040*01" C2 24.67 33.00 12.94 42"50*00" C3 45.10 30.0 28.04 86*08"l 7'2 C4 49.15 0 30.0� 32.09 n9'3051 *43$9 -a TRADE CENTER COURT (SEE TRADE CENTER COURT STREET PLANS) d 0 Ll- 0!,y tt ui 0 cn Lu 0 LLI I_ cl, cl i__ o a. z 0 ui z UJ Lu ir co C) ul uj w m LLJ _j 0 LL ao- cy) cy} w Z ;2� CL :;� Z c) a: < z ZO uw, LML I cr) :c Lu L0 (D C z o czy) tz) 0 Ic- Z u •u a co 2 LLI z co umi z 4. 0 CD o ow cwn om I Io-- W m . Z F,- a 0 LL- 0 'm g z z t5 0 ILLJ > T- (D -00ow4f Duja w LL) CFe- XF- z C) m 0 CWL F=- z 0 az > ui 2L a-' z uj 0 < Z 0 z z CL 0- 0 3: U- U) 2 ow �= 9 �] ? W> (/) 0 zw w w a Lu Z L LLI w 0 Mau) LL cl) 0 ZO zo ucj J L.L U < W (o W (y) 0 0 06 z w C) L_ 0. <lLup<w,wz W 4-1 0 U) CL w 0 z CL 00- ow t 0 < ZZ 0 < z clo w CWL OW FX- W W w Ly i OL, ZLU 'z 0 oz czr) 0 G (o , wo w �< - �E w w o C) 2 ffiw,, zo Z LL- Lij w u- mcn > 0���a 04 CL , cn 9 wo >- 0 u- W �, <:� C6 LLJ 0 0 a. x wo W> 0�_ �- :� z"'z6�w =��° o' , LLco r u, o � > 5_� m 6wwwmw -wig W> < 0 ul- z w m!� D o>: (w co J) Q W F- UJ Lu co 3 w z o uiz=) I �- MCLWF=-00X<M - HORIZONTAL.- 1 is =40' VERTICAL: 1'*=2' + ..352 .... Lo ir CL ...................... ............... r IoW. Z .(o + ..................................... .............................. EXS1)-1A1G GROUND Pl? 0-FIL • A T FL OW Z AF 350 - .... :...:...:...........: ...:...:...:................ . .. ....:...: .............................................. 348 ........................ ............. ........................ .pro.. two �• ............. .......... ..... 12 +00 ** '13 +00 *' 14+00 15+00 WEST FLOWLINE PROFILE 49.15' ON CURVE 0 9;t)' VFPTIrAl r[IRVF. I %-Of I - 41 000 110 N >�NI W4d- a. M�00 a- 00 Lo 00 IDENTICAL POINT 14- M m ,0- clq *In po qd-m Lo nri I w- * 00 14- co • to %t to U co N -J.J 352 + ................... '47 U-7U7(0. 4- r-., M . . . . . . + oo m . T . . . . . . . . . . . . + . . . . . . 352 ......................... *+ w U- U- U- c� z ....... ........... (o ........................ •r . . . . . . ..... .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EXISPIN6 6ROUND PRORIE - . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 350 350 . . . . . .. .__ _ . ................................................... .......................... ................ "Wawa 4mmem : - ' - - .. �:... :...... , . 348 0- . • . . . . . . . . . . . . . . . . . . . . . . . .. .. . +4a: IL mot . d• 5 . . . . . . . . . . . . . . . 348* 0 Z7 •Q . • . . - . . . . . . . . . . . . . . . . . . . DESIGN ROKINE PRMLE ........................................................ ...... 9+aa . . . . . . . . . . . . . . . 1 0+00 ............... 1 . 1 . +00 ......... 12+00 13+00 14+00 15+00 EAST FLOWLINE PROFILE UUKFUKAlt UUUKI (SEE LEFT) R I ROADSIDE SIGN &PAVEMENT D NOTES 1. TRAFFIC STRIPING, PAVEMENT LEGENDS, & RECESSED MARKERS SHALL BE PER CALTRANS STANDARD PLANS AND SPECIFICATIONS DATED MAY 2006 AND THE CALIFORNIA MUTCD 2010 EDITION, DATED JANUARY 211 2010. 2. PAINTING PROCEDURES FOR STRIPING AND MARKINGS SHALL BE PER STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION (APWA/AGC). 3. ALL CONFLICTING MARKINGS SHALL BE REMOVED BY WET SANDBLASTING. ALL CONFLICTING RAISED PAVEMENT MARKERS SHALL BY PRIED OFF AND ANY REMAINING RESIDUE SHALL BE REMOVED BY WET SANDBLASTING. ALL SANDBLASTED AREAS NOT COVERED BY OVERLAY OR SEAL COAT SHALL BE FOG SEALED. 4. ALL SIGNING AND TRAFFIC CONTROL DURING CONSTRUCTION SHALL BE PER THE CALIFORNIA MUTCD 2010 EDITION, DATED JANUARY 21, 2010. 5. ALL POSTS SHALL BE PER CITY STANDARD OR APPROVED EQUAL. 6. STRIPING AND SIGNING TO BE DONE BY THE CONTRACTOR AND IS SUBJECT TO APPROVAL BY THE CITY OF BAKERSF{ELD PUBLIC WORKS DEPARTMENT. 7. STRIPING AND MARKINGS FOR STOP BARS AND "STOP" TEXT SHALL BE THERMOPLASTIC CONFORMING TO SECTION 84 OF THE STATE STANDARD SPECIFICATIONS EXCEPT WHERE NOTED OTHERWISE. 8. ALL PERMANENT STRIPING TO BE THERMOPLASTIC PAINT PER CALTRANS STANDARD SPECIFICATION PTH-02ALKYD 9. ALL CONSTRUCTION MATERIALS FOR ROADSIDE SIGNS, TRAFFIC STRIPING, PAVEMENT MARKERS, AND PAVEMENT MARKINGS SHALL BE FURNISHED AND INSTALLED BY THE CONTRACTOR. 10., 'LANE WIDTHS SHOWN ON THE PLAN ARE DIMENSIONED FROM FACE OF CURB TO CENTER OF STRIPE, OR BETWEEN CENTERS OF STRIPES. 11. ALL EXISTING STRIPING AND PAVEMENT MARKINGS IN THE AREA WHICH IS TO REMAIN AND WHICH IS DAMAGED DUE TO THE CONTRACTOR'S OPERATIONS SHALL BE REPLACED AT THE CONTRACTOR'S EXPENSE. 1 SCALE: 1"=40' PAVEMENT DELINEATION LEGEND INSTALL TRAFFIC STRIPE PER CALTRANS STANDARD PLAN NOS. A20A, A2013, O AND A20D. NUMBER INC)INDICATES DETAIL NO. ON STANDARD PLAN. LL INSTALL 12" WHITE LIMIT LINE AS SHOWN. REMOVE ALL EXISTING PAVEMENT MARKINGS AND/OR TRAFFIC STRIPING IN 0 CONFLICT WITH NEW CONSTRUCTION (TYPICAL). DY INSTALL 12" YELLOW DIAGONALS AS SHOWN (501 MAX O.C.) INSTALL TYPE IV(L) WHITE ARROW CENTERED IN LANE AS SHOWN. STOP INSTALL WHITE "STOP" LEGEND AS SHOWN NOTE: PRIOR TO PAVING, THE DESIGN ENGINEER FOR THE PROJECT SHALL VERIFY CONDITIONS REMAIN THE SAME AS SHOWN IN THE APPROVED PLANS. SHOULD CONDITIONS BE CHANGED, A REVISED STRIPING PLAN SHALL BE SUBMITTED TO THE CITY FOR APPROVAL 10 DAYS PRIOR TO PAVING. SIGN CODES R1 -1 " STOP SIGN R3-2 " NO LEFT TURN NOTE: SIGN CODES ARE FEDERAL CODES UNLESS OTHERWISE INDICATED BY (CA). (CA) INDICATES CALIFORNIA CODES. Lii 0- uj LL cl) cr_ z t CL w ___ w r 0 Z 0 r) z Z w w 1- 2 w 0 W > w LLI LL F_ w 0 < E� cr. < LL 0- © CL \,lt;aER oc bo/l, 41, o Q� 00 S1038 �c SAP 0 (D U) z 0 W w V) • 71 • • • DATE 9/12/2013 PA JOB No. 12-2642N c: Q) SHEET E 0 E co N OF 3 SHEETS �2