Loading...
HomeMy WebLinkAbout2500 BRUNDAGE LANEHOODS ALARMS SPRINKLER SYSTEMS SPRAY 0007H AST UST Permit No. Permit No. Permit No. Permit No. Permit No. Permit No. loom -22-7 File Number: Zoo Address: 25-0 p 610 Bakersfield, CA 933 _ Date Received: 5-- Zz._ i-r— Business Name: Other: Comments: 41d90c Qb'-ceaA c C-e-4- e J L. - IN F'L:;TIcl N LC c; Signature SYSTEM: BUILDING SQUARE FEET: New Mod. Commercial Hood System Building Sq. Feet: Fire Alarm System Calculation Bldg. Sq. Ft: -3 T Fire Sprinkler System Spray Finish System Aboveground Storage Tank Underground Storage Tank minor modification Underground Storage Tank removal Underground Storage Tank Other: Comments: 41d90c Qb'-ceaA c C-e-4- e J L. - IN F'L:;TIcl N LC c; Signature INDEPENDENT FIRE AND SAFETY, INC. 10016 ROSEDALE HWY. BAKERSFIELD, CA C -16 # 800579 (805) 589 -9091 FIRE SYSTEM INSTALLATION DATA JOB NAME: DATE: L.,-5 Moicajete Restaurant 5121112 JOB SITE: CITY: 2500 Brundace Lane Bakersfield, CA CONTRACTOR 1 OWNER: DESIGNER: Armondo Art Montanlo Jr. SYSTEM TYPE: Pyro Chem PCL %0 U.L 300 Wet Chemical System. CONTROL TYPE: Mechanical Control Head Model MCH3 SYSTEM LOCATION: Kitchen Wall Next To Exaust Hood HOOD DIMENSIONS HOOD: 12'x 4' PLENUM: 8'x 2' DUCT: 18" x 18" HOOD: NOZZLES PLENUM: FRYER: DUCT: 15" HOOD NOZZLES: Gas PLENUM: 1H DUCT: 2D DISCHARGE PIPING SUPPLY LINE: 3/8" PLENUM: 318" DUCT: 3/8" APPLIANCE: 318" PIPE TYPE: Black Iron PIPE SCH_: 40# PAGE 1 of 2 APPLIANCE SIZE NOZZLES TYPE FRYER: 14"x 15" 2H Gas FRYER: 14"x 15" 2H Gas FRYER: GRIDDLE: 36" x 24" 2H Gas GRIDDLE: RANGE: 48" x 24" 21-121- Gas RANGE: WOKS: STOCK POT RANGE: STOCK POT RANGE: SALAMANDER: 69" x 12" i L/ 1 L Gas CHAR BROILER: 15" x 24" 1H-, Gas TILTING SKILLET: TILTING SKILLET: y STEAM TABLE: OVEN:` PAGE 1 of 2 SYSTEM NOZZLES MECH. GAS VALVE ELECT. GAS VALVE APPLIANCE: 4@ 2F = 8 flow MODEL: 1112" 1F= 4flow DUCT: 1 2F = 2 flow LINE SIZE: 1112" PLENUM: 190 1E = 1 flow VALVE SIZE: 1112" MODEL: WA LINE SIZE: WA VALVE SIZE: WA TOTAL NOZZLES:(-±L— LOCATION: Main Gas Line To Appliance's. TOTAL FLOW POINTS: 15 MAXIMUM ALLOWABLE FLOW POINTS: 11C, v CORNER PULLEY TYPE: Model S1BP -1 DETECTION EQUIPMENT: FUSIBLE LINK KIT: 5 - Model FLK -1 FUSIBLE LINK: 5 - Model FL-450 LOCATION: in Exhaust Hood Over Appliances. REMOTE PULL STATION: PULL TYPE: Model RPS-M Mechanical PULL LOCATION: On Wall 48" Above The Floor Next To Kitchen Exit Door. SIGNALING DEVICE: STROBE LIGHT: Yes AUDIBLE ALARM: Yes BUILDING ALARM: No SPECIAL NOTES : Electric to hom strobe done by electricial contractor supplied by others. Inspecw By Data PAGE 2of2 LC75 Molcajete Restaurant 2500 Brundage Lane Bakersfield, CA iterr ate PuU_ StediW FRYER FRYER RANGE ( GRIDDLE CHAR BROILER CL PYRO CHEM U.L. 300 INSTALLATION INDEPENDENT FIRE AND SAFETY, INC. 10016 ROSEDALE HWY. BAKERSFIELD, CA C -16 # 800579 (805) 589 -9091 FIRE SYSTEM INSTALLATION DATA JOB NAME: Molca}ets Restaurant JOB SITE: 2500 Brundage Lane DATE: CITY: 5/21/12 Bakersfield, CA CONTRACTOR / OWNER: DESIGNER: Armondo Art Montanlo Jr. SYSTEM TYPE: Pyro Chem PCL 300 U.L. 300 Wet Chemical System. CONTROL TYPE: Mechanical Control Head Model MCH3 SYSTEM LOCATION: Kitchen Wall Next To Exaust Hood HOOD DIMENSIONS HOOD: 7'x 4' PLENUM: 7'x 2' DUCT: 12" x 12" HOOD: PLENUM: DUCT: HOOD NOZZLES: PLENUM: 1 H DUCT: 2D DISCHARGE PIPING SUPPLY LINE: 318" PLENUM: 318" DUCT: 318" APPLIANCE: 318" PIPE TYPE: Black Iron PIPE SCH_: 40# FRYER: FRYER: FRYER: GRIDDLE: GRIDDLE: RANGE: RANGE: WOKS: STOCK POT RANGE: STOCK POT RANGE: SALAMANDER: CHAR BROILER: TILTING SKILLET: TILTING SKILLET: STEAM TABLE: OVEN: PAGE 1 of 2 SIZE 36"k 24" 16''x 16" 16"X 16" APPLIANCE NOZZLES 2H 2L 2L TYPE Gas Gas Gas ilffiw al iIV Itsacx- a.t SYSTEM NOZZLES MECH. GAS VALVE ELECT. GAS VALVE APPLIANCE: 3ft 2F = 6 flow MODEL: 1" MODEL: N/A 001F= 0 flow DUCT: 1ft 2F = 2 ow LINE SIZE: in LINE SIZE: N/A PLENUM: 1@ 1F = 1 flow VALVE SIZE: In VALVE SIZE: NIA TOTAL NOZZLES:-60 LOCATION: Main Gas Line To Appliance's. 1 TOTAL FLOW POINTS: MAXIMUM ALLOWABLE FLOW POINTS: --10i' CORNER PULLEY TYPE: Model SBP -1 DETECTION EQUIPMENT: FUSIBLE LINK KIT: 3 - Model FLK -1 FUSIBLE LINK: 3 - Model FL450 LOCATION: In Exhaust Hood Over Appliances. REMOTE PULL STATION: PULL TYPE: Model RPS-M Mechanical PULL LOCATION: On Wail 48" Above The Floor Next To Kitchen Exit Door. SIGNALING DEVICE: STROBE LIGHT: Yes AUDIBLE ALARM: Yes BUILDING ALARM: No SPECIAL NOTES: Electric to hom strobe done by eiectricial contractor supplied by others. Inspected By Dam PAGE 2of2 L,051 Mok:ajete Restaurant 2500 Brundage Lane Bakersfield,CA TT tr, PYRO CHEM U.L. 300 INSTALLATION 0 0 Fusible Link 0 Fusible Linkt-f 1H Fusible Link PYRO CHEM U.L. 300 INSTALLATION 4, PyrhCend Pyro -Chem Kitchen Knight II KITCHENi PCL- 300/46Qi6QO KNIGHT. II -- Nozzle Coverage Summary Sheet Oi* a Deep Fat Fryer— Vat Deep Fat Fryer (Low Proximity) — Vat Deep Fat Fryer — Drip Pan (Vat 18” x 18' max.) Deep Fat Fryer (Low Proximity) - Drip Pan (Vat 18" x 18' max.) Deep Fat Fryer — Drip Pan (Vat 19 1/2 x 19' max.) Deep Fat Fryer (Low Proximity) - Drip Pan (Vat 191/2" x 19' max.) Two Burner Range Two Burner Range (Low Proximity) Four Burner Range Small Wok Small Wok (Low Proximity) Large Wok Large Wok (Low Proximity) Small Griddle Small Griddle (Low.Proximity) Large Griddle Large Griddle (Low Proximity) Gas Radiant Char - Broiler Gas Radiant Char - Broiler (Low Proximity) Large Gas Radiant Char - Broiler Large Gas Radiant Char-Broiler (Low Proximity) Lava Rock Char - Broiler Natural Charcoal Char - Broiler (max. fuel depth 6 ") Natural Charcoal Char - Broiler (Low Proximity) Mesquite Char- Broiler (max. fuel depth 61) Mesquite Char- Broiler (Low Proximity) UPrighUSalamander Broiler Chain Broiler (Internal Chamber) Tilt SkiileVBraising Pan Plenum Single Bank/V Bank Coverage limitations are.based on fryer sizes including the drip boards. Exception: Tilt Skillets and Braising Parts may exceed maximum of 6 sq. it Nozzle Flow Width LengthTypePoints (ft) (n) 1H 1 4 10 Nozzle Placement (See manual for more detail) 0'— 6" from and of plenum Duct Nozzle Width Length Min. Max. Nozzle Flow in) In) Height Height Type Points . Max- Side Area Sq. In in) in) UnlimitedRectangle/Circular 2D 2H 2 191/2 19 In. 24 48 13 242L 24 482H 2 273/4 500 Sq. In. 13. 242L 24 482H 2 253/.8 495 Sq. In: 13 242L 40 501H 1 12 28 In. 13 241L 28 281n. 34 482L2 24 481H 1 24" dia.. 6' depth 13 241L 2H 24 48230" dia, B" depth 13 242L 1H 24 481361080Sq. In. 10 241L 2H. 2 48 1440 Sq. In. 24 48 10 482L 1H 24 48126624Sq. In. 13 241L 2H 36 48 2L 2 36 864 Sq. In. 13 36 2L 2 26 624 Sq. In. 15 35 1H 1 24 480 Sq. In. 24 48 15 241L 1 H 1 24 35 1L 24 480 Sq. In. 15 24 11- 1 36 W 28 D Front edge; above the grate 1L 1 27 W 38'D Front edge; 1 -3' above the chain Coverage limitations are.based on fryer sizes including the drip boards. Exception: Tilt Skillets and Braising Parts may exceed maximum of 6 sq. it Nozzle Flow Width LengthTypePoints (ft) (n) 1H 1 4 10 Nozzle Placement (See manual for more detail) 0'— 6" from and of plenum Duct Nozzle Flow Max- Side Perimeter Diameter Length RectwVe/Circular Type Points in) in) in) in) 2 34 100 317/8 UnlimitedRectangle/Circular 2D 2) 2D 4 51 150 471/2 Unlimited A MODEL MCH3 - MECHANICAL CONTROL HEAD (P /N 551200) The Model MCH3 mechanical control head is a fullymechanicalcontrolheadwhichcanbeconnectedto thePCL- 300/460/600 cylinder valve. This control head will sup- port a fusible link detection system, a remote mechanicalPullstation (Model RPS -M), and a mechanical or.electric gasshutoffvalve. A miniature electric switch (Model MS -SPDT, MS =DPDT, MS -3PDT, or MS -4PDT) can be ordered sepa- rately and field installed. It is equipped with a local manualcontrolhandlethatallowsformechanicalsystemactuation. Operation of the local manual control requires removing thepullpinandrotatingthehandleclockwise. The Model MCH3controlheadcanactuateamaximumofthree (3) cylinders. See Figure 2-4. MODEL MCH3 CONTROL HEAD MK T" 70 AELAUZ ,W FM oa, W12rIL.na UL Figure 2-4. Mechanical Control Head. oa79OPc MODEL ECH3 -- ELECTRIC CONTROL HEAD The Model ECH3 electric control head is an electrically oper- ated control head which can be connected to the PCL - 300/460/600 cylinder valve. This control head will support anelectricthermaldetectionsystem, a remote mechanical pull. station (Model RPS -M), and an electric gas shutoff valve. Itwillnotsupportafusiblelinkdetectionsystem. A.miniatureelectricswitch (Model MS -DPDT) is included. The ModelECH3controlheadisavailableinboth120VAC (ModelECH3 -120, P/N 551202) and 24 VDC (Model ECH3 -24, P/N551201). It is equipped with a local manual control handlethatallowsformechanicalsystemactuation. Operation of thelocalmanualcontrolrequiresremovingthepullpinandrotat- ing the handle clockwise. The Model ECH3 control head cantactuateamaximumofthree (3) cylinders. See Figure 2 -5: MODEL ECH3 CONTROL HEAD Pt" nt 7ua 1y cu TO Meaee rae ornmMa src7r„ ri nwiaaa U Figure 2 -5. Electric Control Head. oa78opc Chapter 2 — Components Page 2 -3 MODEL NMCH3 - MECHANICAL' CONTROL HEAD (P /N 551203) The Model NMCH3 Mechanical Control Head is a fullymechanicalcontrolheadwhichcanbeconnectedtothe PCL- 300/460/600 cylinder valve. This control head will sup- port a fusible link detection system, a remote mechanical pullstation (Model RPS -M), and a mechanical or electric gas shut -off valve. .A miniature electrical switch (Model MS -SPDT, MS -DPDT, MS -3PDT, or MS -4PDT) can be ordered separate- ly and field installed. There is no local manual actuation for the Model NMCH. The Model NMCH3 control head can actu- ate a maximum of three (3) cylinders. The.Model NMCH3 can be used as a direct replacement for the Model MCH3. MODEL EN -MCU3 ENCLOSURE P /N 551208) The Model EN -MCU3 Enclosure is used for vertical mount- ing of a single PCL -300 or PCL -460. The EN -MCU3 also includes a mechanical control unit, eliminating the need for aModelMCH3ControlHead. See Figure 2 -6. The PCL -600 cannot be mounted in an EN -MCU3. o O0 28.125 LIL — - — -- — - J 13.125 -- I 10.625 -I Figure 2-6. Model EN -MCU3 Enclosure. om 5pc MODEL EN -S ENCLOSURE PM 550966) The Model EN -S Enclosure is used for vertical mounting of a single PCL -300 or PCL -460 when it is used as a secondaryagentcylinderinasystem. The EN -S has no control mecha- nism, and must be used in conjunction with a Model EN -MCU3 Enclosure or a,Model MCH3 /ECH3 Control Head. The PCL -600 cannot be mounted in an EN -S. ULEX 3470 PN551274 October 1, 2001 fi, CYLINDERS & VALVE CHAPTER II COMPONENTS The Pyro -Chem Kitchen Knight II System has available threedifferentsizecylinders: the Models PCL -300 (P %N 551194), PCL -460 (P /N 551193), and PCL -600 (P /N 551196). Cylindersizesareexpressedintermsofextinguishingagentcapacityi:e:, the PCL -300 uses 3.0 gallons of extinguishing agent). The cylinder is manufactured, tested, and marked in accor- dance with DOT 4BW225. Cylinders come pre - filled withextinguishingagentandarechargedwithdrynitrogento aPressureof225psig ® 70' F. Cylinder and valve assemblydimensionsareshowninFigure2 -1. R B D 1 A—{ Model Max. Flow No A 6 C Point C PCL-300 8.00 25.06 30.81 22 75 ac' PCL 460 10.00 25.06 30.81 22.75 PCL -600 10.00 35.81 41.56 33-501 15 20 bs.MS-15 Figure 2 -1. Cylinder and Valve Assemblies. 00MIPC All cylinders utilize the same valve assembly (P /N 551175) It is a pressure sealed poppet type valve designed to pro- vide rapid actuation and discharge of agent. See Figure 2 -2. Chapter 2 — Components Page 2 -1 Figure 2 -2. Valve Cross Section. OW12PC VALVE REBUILDING EQUIPMENT 1. Wet Valve Seal Rebuilding Kit (P /N550698). After system discharge, the valve assembly must be rebuilt toensureproperfutureoperation. The .Wet Valve Seal Rebuild - ingXt (P /N 550698) should be used. It includes all compo- nents necessary to properly rebuild the valve. See Figure 2 -3. C..0)oo dr Figure 2 -3. Wet Valve Seal Rebuilding KitP /N 550698). 0am"PC Part Number Description 5 ULEX 3470 PN551274 October 1, 2pp1 A. Chapter 2 — Components Page 2 -5 DETECTION EQUIPMENT 3. Model FLH -1 (P /N 550876). 1. Model FLK -1 (P /N 550131). The Model FLH -1 fusible link hanger is an accessory designed to simplify the installation of fusible links in the The Model FLK 1 fusible link kit includes a 10" steel bracket, fusible link line. It can be used with the Model FLK -1/1A two (2) 1/2" EMT connectors, two (2) cable crimps, and two S" fusible link kit (kits must be ordered separately). The Fusible Link Hanger makes it possible to install fusible links without2) hooks. Fusible links must be ordered separately. See Figure 2 -9. cutting and crimping loops in the fusible link line for each link. They are available in packages of 25 (FLH -25) only. See Figure 2 -10. 2. Model FLK -1 A (P /N 550132). The Model FLK -1A fusible link kit includes an 8" steel brack- et, two (2) 1/2" EMT connectors, two (2) cable crimps, and two (2) "S" hooks. Fusible links must be ordered separately. LINK DETECTOR BRACKET TERMINAL LINK S -HOOK 1116' STAINLESS STEEL CABLE FUSIBLE UNK SERIES LINK CABLE CRIMP Figure 2 -9. Model FLK -1 Fusible Link ooxuOPC FUSIBLE LINK KIT SOLD SEPARATELY) FUSIBLE LINK SOLD SEPARATELY) FLH-1 FUSIBLE LINK HANGER Figure 2 -10. Model FLH -1 Fusible LInk.Hanger 0=85opc 1/Y EMT CONNECTOR ULEX 3470 PN551274 October 1, 2001 h hapter 2 ,- Components age 2 -6 4. Fusible Links. The fusible link is designed to separate at a specific temper- ature, releasing tension from the fusible link line, causingsystemactuation. See Figure 2 -11. Figure 2 -11. ML Style Fusible Link. 0i0°7PC After determining the maximum ambient temperature at the fusible link location, select the correct fusible link accordingtothetemperatureconditionchartbelow: Fusible Link Maximum Ambient EMT with corner pulleys at each change in direction. The remote mechanical pull station shall be located at the pointofegress. See Figure 2 -12. CID tD IN CASE Of tit W ® m STANDARD4- x4- ELL ANCTIO + BOX WOOED BRUSHED ALUIMS 1 FACE PLATE RED KWIC BMWROD Model No. Temperature Part Number W o ' Wwto FL -165 95° F. (35° C.) 550368 P=WAND E FL -212. 142° F. (61 ° C.) 550365 1W FL -280 210° F. (99° C.) 550366 ON ALL COMM FL -360 290° F. (143° C.) 550009 Figure 2 -12. Model RPS -M Mechanical Pull Station. FL -450 380° F. (193° C.) 550367 maupc FL -500 430° F. (221° C.) 56816 GAS SHUTOFF VALVES 5. Thermal Detectors. Fixed temperature thermal detectors are normally open, 1 - Mechanical Gas Shutoff Valve. mechanical contact closure switches designed to operate atafactorypresettemperature. They A gas shutoff valve is required on all systems used to pro - are available in four pre- set temperatures which meet NFPA standards and tect a gas fueled cooking appliance to stop gas flow in theeventareULListedandFMApproved. After determining of system actuation. A mechanical gas valve can bethemaximumambienttemperatureatthethermaldetectorusedwiththeModelMCH3controlhead. It is connected to location, select the correct thermal detector according the system control head by stainless steel cable. This cabletothetemperatureconditionchartbelow: Is enclosed in 1/2" EMT with a corner-pulley at each changeindirection. The valves are rated for natural and LP gasThermal. see Figure 2 -13). Mechanical gas valves are available inDetectorMaximumAmbientthefollowingsizes: Model No. Temperature Part NumberTD -225 155° F. (68° C.) 13976 Maximum TD -325 255° F. (124° C.) 13975 Valve OperatingTD -450 380° F. (193° C) 13974 Model No. Size Pressure Part NumberTD -600 530° F. (277° C.) 13971 GV -75 3/4" 5 psi 550593 MODEL RPS -M - REMOTE GV -100 in 5 psi 550594GV -125 1-1/4" 5 550595 MECHANICAL PULL STATION psi GV -150 1 -1/2" 5 psi 550596GV P /N 551074) 200 2° 5 psi 551049GV -250 2 -1/2" 5 550185 Remote manual control for the Model MCH3, NMCH3, psi GV -300 3" 5 psi 550186 orECH3controlheadisprovidedbytheModelRPS -M remotemechanicalpullstation. It is connected to the system controlheadbystainlesssteelcable. This cable is enclosed in 1/2" X 3470 Ober 1, 2001 PN551274 A. 0 Pyro Chent o GAB VALVE StW -OFF O 0 0 Figure 2 -13. GV- Series Mechanical Gas Valve. 002853PC 2. Electric Gas Shutoff Valve. A gas shutoff valve is required on all systems used to pro- tect a gas fueled cooking appliance to stop gas flow in the event of system actuation. A UL Listed electric gas valve can be used with either the Model MCH3 or ECH3 control head. The valves are rated for natural and LP gas. Valves are available in 120 VAC. Electric gas valves are available in the following sizes: Note: A UL Listed manual reset relay is required when using an electric gas valve. The Pyro -Chem Kitchen Knight II Model SM -120 solenoid monitor may be used for this pur- pose. Chapter 2 — Components Page 2 -7 CORNER PULLEYS 1. Model SBP -1 (P /N 415670). A corner.pulley is used whenever a change in stainless steel cable direction is required. The Model SBP -1 corner pulley is equipped with a set screw fitting for connection to 112" EMT. See Figure 2 -14. Figure 2 -14. Model SBP -1 Corner Pulley. 000166 2. Model CBP -1 (P /N 423250). A corner pulley is used whenever a change in stainless cable direction is required. The Model CBP -1 is a grease - tight corner pulley designed for areas likely to experience excessive deposit build -up. It is equipped with a compres- sion fitting for connection to 1/2" EMT. See Figure 2 -15. Note: The Model CBP -1 is not a liquid tight seal for penetra- tion of hoods and/or ducts. r, 'I I Figure 2 -15. Model CBP -1 Corner Pulley. ao0161 3. Model WBP -1 (P /N 550982). A corner pulley is used whenever a change in stainless. cable direction is required. The Model. WBP -1 is a weather- proof comer pulley designed for areas likely to be exposed to moisture. It is equipped with female pipe threads for con- nection to 1/2" rigid conduit. See, Figure 2 -15a. I ci Figure 2 -15a. Model WBP -1 Corner Pulley. 000161 ULEX 3470 PN551274 October 1, 2001 Maximum Valve Operating Model No. Size Pressure Part Number EGVSO -75 3/4" 50 psi 550358 EGVSO -100 1" 25 psi 550359 EGVSO -125. 1 -1/4" 25 psi 550360 EGVSO -150 1 -1/2" 25 psi 550361 EGVSO -200 2" 25 psi 550362 EGVSO -250 2 -1/2" 25 psi 550363 EGVSO -300 3" 25 psi 550385 Note: A UL Listed manual reset relay is required when using an electric gas valve. The Pyro -Chem Kitchen Knight II Model SM -120 solenoid monitor may be used for this pur- pose. Chapter 2 — Components Page 2 -7 CORNER PULLEYS 1. Model SBP -1 (P /N 415670). A corner.pulley is used whenever a change in stainless steel cable direction is required. The Model SBP -1 corner pulley is equipped with a set screw fitting for connection to 112" EMT. See Figure 2 -14. Figure 2 -14. Model SBP -1 Corner Pulley. 000166 2. Model CBP -1 (P /N 423250). A corner pulley is used whenever a change in stainless cable direction is required. The Model CBP -1 is a grease - tight corner pulley designed for areas likely to experience excessive deposit build -up. It is equipped with a compres- sion fitting for connection to 1/2" EMT. See Figure 2 -15. Note: The Model CBP -1 is not a liquid tight seal for penetra- tion of hoods and/or ducts. r, 'I I Figure 2 -15. Model CBP -1 Corner Pulley. ao0161 3. Model WBP -1 (P /N 550982). A corner pulley is used whenever a change in stainless. cable direction is required. The Model. WBP -1 is a weather- proof comer pulley designed for areas likely to be exposed to moisture. It is equipped with female pipe threads for con- nection to 1/2" rigid conduit. See, Figure 2 -15a. I ci Figure 2 -15a. Model WBP -1 Corner Pulley. 000161 ULEX 3470 PN551274 October 1, 2001 V Pyro-ChemPyroKitchenKnight II KITCHEN PCL- 300/460/600 CC KNIGHT. -- Nozzle Coverage Summary Sheet Width Length Min. Max. Appliance Nozzle Flow in) in) Height Height Type Points., Max. Side Area Sq. In in) (in) Deep Fat Fryer – Vat 2H Deep Fat Fryer (L)w Proximity) – Vat 2L 2 191/2 19 In. 24 48 13 24 Deep Fat Fryer – Drip Pan (Vat 18' x 18` max.) 2H Deep Fat Fryer (Low Proximity) - Drip Pan (Vat 18" x 18' max.) 2L 2 27 3/4 500 Sq. In. 24 48 13, 24 Deep Fat Fryer – Drip Pan (Vat 19 1/2 x 19" max.) 2H Fat FDeepFryer (Low Proximity) - Drip Pan (Vat 191/2' x 1.9' max.) 2L 2 25 3/8 495 Sq. In. 24 48 13 24 Two Burner Range 1 H Two Burner Range (Low Proximity) 1 12 28 In. 40 50 1L 13 24 Four Burner Range 2L 2 28 28 In. 34 48 Small Wok 1 H 24 48 Small Wok (Low Proximity) 1 24" dia. 6' depth1L 13 24 Large Wok Large Wok (Low Proximity) 2H 2 30' dta. 8' depth 24 48 2L 13 24SmallGriddle1H2448 Small Griddle (Low.Proximity) 1 36 1080 Sq. In. 1L 10 24 Large Griddle 2H, Large Griddle (Low Proximity) 2 48 1440 Sq. In. 24 48 L 10 48GasRadiantChar - Broiler 1 24 48 Gas Radiant Char - Broiler (Low Proximity) 1 26 624 Sq. In. 1L 13 24 Large Gas Radiant Char - Broiler Large Gas Radiant Char-Broiler, (Low Proximity) 2H 2 36 864 Sq. In. 36 48 2L 13 36LavaRockChar - Broiler Natural Charcoal Char- Broiter (max, fuel depth 6') 2L 2 26 624 Sq. In. 15 35 Natural Charcoal Char - Broiler (Low Proximity) 1H 1 24 480 Sq. In. 24 48 Mesquite Char - Broiler (max. fuel depth 6`) 1L' 15 24 Mesquite Char - Broiler (Low Proximity) 1H 1 24 480 Sq. In. 24 35 UprighUBalamander Broiler 1 L 15 24 1L 1 36 W 28 D Front edge; Chain Broiler (Internal Chamber) above ft grate 1L 1 27 W 38 D Front edge; Tik SkiUet/Braising Pan 1 -3" above the chain Coverage limitations are.based on fryer sizes including the drip boards. Exception.111t Skillets and Braising Pans may exceed maximum of 6 sq. ft. Plenum NOUle Type Flow Points Width Length Noah Placarnent (See Single SankN Bank ft) ft) manual for more detail) 1H 1 4 10 0'- 6'from end of plenum Duct Nye Flow Max. Side Perimeter Diameter Length Type Points in) in) in) (in) Rectangle/Circular Rectangle/Circular 2D 2 34 100 317/8 Unlimited 12) 2D 4 51 150 471/2 Unlimited MODEL MCH3 - MECHANICAL CONTROL HEAD (P /N 551200) The Model MCH3 mechanical control head is a fullymechanicalcontrolheadwhichcanbeconnectedto thePCL- 300/460/600 cylinder valve. This control head will sup- port a fusible link detection system, a remote mechanicalPullstation (Model RPS -M), and a mechanical or.electric gasshutoffvalve. A miniature electric switch (Model MS -SPDT, MS -DPDT, MS -3PDT, or MS -41PDT) can be ordered sepa- rately and field installed. It is equipped with a local manualcontrolhandlethatallowsformechanicalsystemactuation. Operation of the local manual control requires removing thepullonandrotatingthehandleclockwise. The Model MCH3controlheadcanactuateamaximumofthree (3) cylinders. See Figure 2-4. MODEL MCH3 CONTROL HEAD MW Mau 70 IH91W 1M rm a" amf'a'iAna ut. Figure 2 -4. Mechanical Control Head. MONK MODEL ECH3 - ELECTRIC CONTROL HEAD The Model ECH3 electric control head is an electrically oper- ated control head which can be connected to the PCL - 300/460/600 cylinder valve. This control head will support anelectricthermaldetectionsystem, a remote mechanical pullstation (Model RPS -M), and an electric gas shutoff valve. It will not support a fusible link detection system. A miniature electric switch (Model MS -DPDT) is included. The ModelECH3controlheadisavailableinboth120VAC (ModelECH3 -120, P/N 551202) and 24 VDC (Model ECH3 -24, P/N551201). It is equipped with a local manual control handlethatallowsformechanicalsystemactuation. Operation of thelocalmanualcontrolrequiresremovingthe. pull pin and. rotat- ing the handle clockwise. The Model ECH3 control head caniactuateamaximumofthree (3) cylinders. See Figure 2 -5. MODEL ECH3 CONTROL HEAD Q M41 MLnmKWU tHr rmo nee rnfo -au U Figure 2 -5. Electric Control Head. 00470 PC Chapter 2 - Components Page 2 -3 MODEL NMCH3 - MECHANICAL CONTROL HEAD (P /N 551203) The Model NMCH3 Mechanical Control Head is a fully mechanical control head which can be connected to the PCL- 3001460/600 cylinder valve. This control head will sup- port a fusible link detection system, a remote mechanical pull station (Model RPS -M), and a mechanical or electric gas shut -off valve. A miniature electrical switch (Model MS -SPDT, MS -DPDT, MS -3PDT, or MS -4PDT) can. be ordered separate- ly and field installed. There is no local manual actuation for the Model NMCH. The Model NMCH3 control head can actu- ate a maximum of three (3) cylinders. The.Model NMCH3 can be used as a direct replacement for the Model MCH3. MODEL EN -MCU3 ENCLOSURE P /N 551208) The Model EN -MCU3 Enclosure is used for vertical mount- ing of a single PCL -300 or PCL -460. The EN -MCU3 also includes a mechanical control unit, eliminating the need for aModelMCH3ControlHead. See Figure 2 -6. The PCL -600 cannot be mounted in an EN -MCU3. o 00 28.125 13.125 —I 1.-10.625 -0-I 04KWT) MM) Figure 2-6. Model EN -MCU3 Enclosure. oamsrc MODEL EN -S ENCLOSURE P/N 550966) The Model EN -S Enclosure is used for vertical mounting of asinglePCL -300 or PCL -460 when it is used as a secondaryagentcylinderinasystem. The EN -S has no control mecha. nism, and must be used in conjunction with a Model EN -MCU3 Enclosure or a•Model MCH3 /ECH3 Control Head. The PCL -600 cannot be mounted in an EN -S. ULEX 3470 PN551274 October 1, 2001 CYLINDERS & VALVE CHAPTER II COMPONENTS The Pyro -Chem Kitchen Knight II System has available threedifferentsizecylinders: the Models PCL -300 (P %N 551194), PCL -460 (P /N 551193), and PCL -600 (P /N 551196). Cylindersizesareexpressedintermsofextinguishingagentcapacityie., the PCL -300 uses 3.0 gallons of extinguishing agent). The cylinder is manufactured, tested, and marked in accor- dance with DOT QW225. Cylinders come pre - filled withextinguishingagentandarechargedwithdrynitrogento apressureof225psig ® 70° F. Cylinder and valve assemblydimensionsareshowninFigure2 -1. Model No. I A 1 13 1 C D v-YOU iu.uu 25.08 30.81 22.75 PC' -600 10.00 35.81 41.56 33.50 MaJIP MB-1 Figure 2 -1. Cylinder and Valve Assemblies. mzaiPc All cylinders utilize the same valve assembly (P /N 551175). It is a pressure sealed poppet type valve designed to pro- vide rapid actuation and discharge of agent. See Figure 2 -2. Chapter 2 — Components Page 2 -1 Figure 2-2. Valve Cross Section. OW12PC VALVE REBUILDING EQUIPMENT 7 - Wet Valve Seal Rebuilding Kit (P /N550698), After system discharge, the valve assembly must be rebuilt to ensure proper future operation. The Wet Valve Seal Rebuild - ing.Kit (P /N 550698) should be used. It includes all compo- nents necessary to properly rebuild the valve. See Figure 2 -3. o 1 Figure 2 -3. Wet Valve Seal Rebuilding KitP /N 550698). o0eaoepc Part Number Description ULEX 3470 PN551274 October 1, 2001 Chapter 2 Components Page 2 -5 DETECTION EQUIPMENT 3. Model FLH -1 (P /N 550876). 1. Model FLK -1 (P /N 550131). The Model FLH -1 fusible link hanger is an accessory designed to simplify the installation of fusible links in the The Model FLK -1 fusible link kit includes a 10" steel bracket fusible link line. It can be used with the Model FLK -1 /1A two (2) 1/2" EMT connectors, two (2) cable crimps, and two S" fusible link kit (kits must be ordered separately). The Fusible Link Hanger makes it possible to install fusible finks without2) hooks. Fusible links must be ordered separately. See Figure 2 -9. cutting and crimping loops in the fusible link line for each link. They are available in packages of 25 (FLH -25) only. See Figure 2 -10. 2. Model FLK -1 A (P /N 550132). The Model FLK -1A fusible link kit includes an 8" steel brack- et, two (2) 1/2" EMT connectors,. two (2) cable crimps, and two (2) "S" hooks. Fusible links must be ordered separately. LINK DETECTOR BRACKET-\ TERMINAL LINK S-MOOK — MOO STAINLESS STEEL CABLE FUSIBLE LINK— SERIES LINK CABLE CRIMP Figure 2 -9. Model FLK -1 Fusible Link oozaoPc FUSIBLE LINK KIT SOLD SEPARATELY) FUSIBLE LINK SOLD SEPARATELY) FLH-1 FUSIBLE UNK F'I WER Figure 2 -10. Model FLH -1 Fusible Link.Hanger 002BSDPC 1/2" EMT CONNECTOR ULEX 3470 PN551274 October 1, 2001 hapter 2 -- Components aoe 2 -6 4. Fusible Links. The fusible link is designed to separate at a specific temper- ature, releasing tension from the fusible link line, causingsystemactuation. See Figure 2 -11. Figure 2 -11. ML Style Fusible Link. 00MIPC After determining the maximum ambient temperature at the fusible link location, select the correct fusible link accordingtothetemperatureconditionchartbelow: Fusible Link Maximum Ambient EMT with corner pulleys at each change in direction. The remote mechanical pull station shall be located at the point of egress. See Figure 2 -12. m m IN CASE OF FIRE Puss M L m Sm STAMARO t x s• ELE. JUNCTION Box MOOED BRUBM® AI JN M1Y FACE PLATE RED PLASTIC arm" RW I i i f Model No. Temperature Part Number W FL -165 95° F. (35° C.) 550368 vuLCNAMxE FL -212. 142° F. (61 ° C.) 550365FL -280 210° F. (99° C.) 550366 ONALICORNEM FL -360 290° F..(143° C.) 550009 Figure 2 -12. Model RPS -M Mechanical Pull Station. FL -450 380° F. (193° C.) 550367 00202PC FL -500 430° F. (221 ° C.) 56816 5. Thermal Detectors. GAS SHUTOFF VALVES Fixed temperature thermal detectors 1- Mechanical Gas Shutoff Valve. are normally open, mechanical contact closure switches designed to operate atafactorypresettemperature. They A gas shutoff valve is required on all systems used to pro - are available in four pre- set temperatures which meet NFPA standards and are UL tect a gas fueled cooking appliance to stop gas flow in theeventListedandFMApproved. After determining of system actuation. A mechanical gas valve can bethemaximumambienttemperatureatthethermaldetectorusedwiththeModelMCH3controlhead. It is connected tolocation, selectthecorrectthermaldetectoraccording the system control head by stainless steel cable. This cabletothetemperatureconditionchartbelow: is enclosed in 1/2" EMT with a corner pulley at each change in direction. The valves are rated for natural and LP gasThermal. see Figure 2 -13). Mechanical gas valves are available inDetectorMaximumAmbientthefollowingsizes: Model No. Temperature Part NumberTD -225 155° 6FC.) 13976 Maximum TD -325. 255° F. (124° C.) 13975 Valve Operating TD -450 380° F. (193° C.) 13974 Model No. Size Pressure Part NumberTD -600 530° F. (277° C.) 13971 GV -75 3/4" 5 psi 550593 MODEL RPS -M - REMOTE GV -100 1 " 5 psi 550594GV-125 1 -1/4" 5 550595 I MECHANICAL PULL STATION psi Gv 2„1/2" 551048P /N 551074) 200 5 psiGV -250 2 -1/2" Remote manual control for the Model 5 psi 550185GV -300 3" 5 psi 550186MCH3, NMCH3, orECH3controlheadisprovidedbytheModelRPS -M remotemechanicalpullstation. It is connected to the system controlheadbystainlesssteelcable. This cable is enclosed in 1/2" X 3470 cber 1, 2001 PN551274 o Pyro Chard C GASVALVE SHUT-OFF n 0 o Figure 2 -13. GV- Series Mechanical Gas Valve. 004667PC 2. Electric Gas Shutoff Valve. A gas shutoff valve is required on all systems used to pro- tect a gas fueled cooking appliance to stop gas flow in the event of system actuation. A UL Listed electric gas valve can be used with either the Model MCH3 or ECH3 control head. The valves are rated for natural and LP gas. Valves are available in 120 VAC. Electric gas valves are available in the following sizes: Note: A UL Listed manual reset relay Is required when usinganelectricgasvalve. The Pyro -Chem Kitchen Knight It Model SM -120 solenoid monitor may be used for this.pur- pose. Chapter 2 — Components Page 2 -7 CORNER PULLEYS 1. Model SBP -1 (P /N 415670). A corner.pulley is used whenever a change in stainless steel cable direction is required. The Model SBP -1 corner pulley is equipped with a set screw fitting for connection to 1/2" EMT. See Figure 2 -14. 0a Figure 2 -14. Model SBP -1 Corner Pulley. o60,6o 2. Model CBP -1 (P /N 423250). A corner pulley is used whenever a change in stainless cable direction is required. The Model CBP -1 is a grease - tight comer pulley designed for areas likely to experience excessive deposit build -up: It is equipped with a compres- sion fitting for connection to 1/2" EMT. See Figure 2 -15. Note: The Model CBP -1 is not a liquid tight seal for penetra- tion of hoods and/or ducts. I Figure 2 -15. Model CBP -1 Corner Pulley. 600,6, 3. Model WBP -1 (P /N 550982). A corner pulley is used whenever a change in stainless cable direction is required. The Model., WBP -1 is a weather- proof corner pulley designed for areas likely to be exposed to moisture. It is equipped with female pipe threads for con- nection to 1/2" rigid conduit. See. Figure 2 -15a. 70,A Figure 2 -15a. Model WBP -1 Corner Pulley. OW16, ULEX 3470 PN551274 October 1, 2001 Maximum Valve Operating Model No. Size Pressure Part Number EGVSO -75 3/4" 50 psi 550358 EGVSO -100 1" 25 psi 550359 EGVSO -125. 1 -1/4" 25 psi 550360 EGVSO -150 1 -1/2" 25 psi 550361 EGVSO -200 2" 25 psi 550362 EGVSO -250 2 -1/2" 25 psi 550363 EGVSO -300. 3" 25 psi 550385 Note: A UL Listed manual reset relay Is required when usinganelectricgasvalve. The Pyro -Chem Kitchen Knight It Model SM -120 solenoid monitor may be used for this.pur- pose. Chapter 2 — Components Page 2 -7 CORNER PULLEYS 1. Model SBP -1 (P /N 415670). A corner.pulley is used whenever a change in stainless steel cable direction is required. The Model SBP -1 corner pulley is equipped with a set screw fitting for connection to 1/2" EMT. See Figure 2 -14. 0a Figure 2 -14. Model SBP -1 Corner Pulley. o60,6o 2. Model CBP -1 (P /N 423250). A corner pulley is used whenever a change in stainless cable direction is required. The Model CBP -1 is a grease - tight comer pulley designed for areas likely to experience excessive deposit build -up: It is equipped with a compres- sion fitting for connection to 1/2" EMT. See Figure 2 -15. Note: The Model CBP -1 is not a liquid tight seal for penetra- tion of hoods and/or ducts. I Figure 2 -15. Model CBP -1 Corner Pulley. 600,6, 3. Model WBP -1 (P /N 550982). A corner pulley is used whenever a change in stainless cable direction is required. The Model., WBP -1 is a weather- proof corner pulley designed for areas likely to be exposed to moisture. It is equipped with female pipe threads for con- nection to 1/2" rigid conduit. See. Figure 2 -15a. 70,A Figure 2 -15a. Model WBP -1 Corner Pulley. OW16, ULEX 3470 PN551274 October 1, 2001 i BILLING & PERMIT STATEMENT iwi „; - SAKE RSFIELD FIRE DEPARTMENT h Prevention Services PERMIT # FIRB 2101 H StreetAR1rf Bakersfield, CA 93301 Aii permits must De revie"d, stamped, and approved PRIOR TO BEGINNING WORK. TM. PERMIT TYPE FEE CALCULATION • AC9 Alarm - New & Modification (mini mum charge) $280 DUE Over 10,000 sq ft 0 .028 x sq ft Sprinkler - New & Modification (rhinimum charge) $280 Over 10,000 sq ft ! $0 .028 x sq ft Sprinkler - Minor Modification ( <10 heads) $ 96 (Inspection only) 84 Commercial Hood (New & UL 300 Upgrade Modification) 0 Additional Hood i 8 Commercial Hood - Minor Modification (add /move nozzle) $ 96 (inspection only) 84 I SDrav Booth (New R MrviifiraNnnl _ 6 311 JPMorgan Chase Bank, N.A. Independent Fire and Safety, Inc. www.Chase.com 10016 ROSEDALE HWY. BAKERSFIELD, CA 93312 90- 7162 -3222 661) 589.9091 5/22/2012 5 PAY TO THE ORDER OF Bakersfield Fire Department- Permits $ * *528.00 Five Hundred Twenty -Eight and 00/ 100*************************************************** * * * * * * * * * * * * * * * * * * * * * " "` * * * * * ** DOLLARS Bakersfield Fire Department 81501TruxtunAve1stFloor ; t_ Bakersfield, CA 93301 MEMO ion S® y5ttem lnatapatgn Permit 111006 3 L L0 1: 3 2 2 2 7 L6 2 71: 308 3 50688911' SIGNATURE 34 13 Portable LPG (Propane): # of Cages? — $ 96 /hr 84 Explosive Storage ! $266 84 Copying & File Research (File Research fee $50 /hr) $0.25 /page 84 Miscellaneous 84 SITE INFORMATION LOCATION OF PROJECT PROPERTY OWNER l0 NAMESTARTINGDATECOMONDATE PROJECT NAME ti ADDRESS PHONE # PROJECTADDRESS CITY pA 1`/ ESFI FL-D STATE CA ZIP CODE CONTRACTOR ME CA LICENSE #' TYPE OF LICENSE EXPIRATION DATE PHONE # CONTRACjaQ.G9MP NY NAME FAX # P ADDRESS CITY ZIP CODE 7 ! Aii permits must De revie"d, stamped, and approved PRIOR TO BEGINNING WORK. TM. PERMIT TYPE FEE CALCULATION • AC9 Alarm - New & Modification (mini mum charge) $280 DUE Over 10,000 sq ft 0 .028 x sq ft Sprinkler - New & Modification (rhinimum charge) $280 Over 10,000 sq ft ! $0 .028 x sq ft Sprinkler - Minor Modification ( <10 heads) $ 96 (Inspection only) 84 Commercial Hood (New & UL 300 Upgrade Modification) 0 Additional Hood i 8 Commercial Hood - Minor Modification (add /move nozzle) $ 96 (inspection only) 84 I SDrav Booth (New R MrviifiraNnnl _ 6 311 JPMorgan Chase Bank, N.A. Independent Fire and Safety, Inc. www.Chase.com 10016 ROSEDALE HWY. BAKERSFIELD, CA 93312 90- 7162 -3222 661) 589.9091 5/22/2012 5 PAY TO THE ORDER OF Bakersfield Fire Department- Permits $ * *528.00 Five Hundred Twenty -Eight and 00/ 100*************************************************** * * * * * * * * * * * * * * * * * * * * * " "` * * * * * ** DOLLARS Bakersfield Fire Department 81501TruxtunAve1stFloor ; t_ Bakersfield, CA 93301 MEMO ion S® y5ttem lnatapatgn Permit 111006 3 L L0 1: 3 2 2 2 7 L6 2 71: 308 3 50688911' SIGNATURE 34 13 Portable LPG (Propane): # of Cages? — $ 96 /hr 84 Explosive Storage ! $266 84 Copying & File Research (File Research fee $50 /hr) $0.25 /page 84 Miscellaneous 84 BILLING & PERMIT STATEMENT ;id "; i. BAKERSFIELD FIRE DEPARTMENT Prevention Services PERMIT # FIRE 2101 H Street Bakersfield, CA 93301 All permits must be revie", d, stamped, and approved PRIOR TO BEGINNING WORK. 0 Alarm - New & Modification (minimum INFORMATION 280 LOCATION OF PROJECT r' I PROPERTY OWNER 0 STARTING DATE COM ON DATE NAME PROJECT NAME / 0 ,% / L05 1OfGrA ADDRESS PHONE # j C-7 G charge) 280 PROJECT ADDRESS j gf f'CERSF16LD STATE Cis ZIP CODE T R INFORMATION Sprinkler - Minor Modification (i 10 heads) 96 (Inspection only) Aft CONTRACTOR ME CA LICENSE TYPE OF LICENSE EXPIRATION DATE PHONE Commercial Hood (New & UL 300 Upgrade Modification) Additional Hood j 51 09/ CONTRACIW6 -WMP NY NAME 0 FAX t I / 84 ADDRESS 0 0 CITY ZIP CODE 470 180 /tank i L All permits must be revie", d, stamped, and approved PRIOR TO BEGINNING WORK. 0 Alarm - New & Modification (minimum charge) 280 0 Over 10,000 sq ft 0 .028 x sq ft 0 Sprinkler - New & Modification (minimum charge) 280 0 Over 10,000 sq ft T 0 .028 x sq ft 0 Sprinkler - Minor Modification (i 10 heads) 96 (Inspection only) Aft 84 Commercial Hood (New & UL 300 Upgrade Modification) Additional Hood 0 5.22-Z 81hggd 0 Commercial Hood - Minor Modi Iicatlon (add /move nozzle) 96 (inspection only) 84 0 0 Spray Booth (New & Modification) boveground Storage Tank (1 inspection per installation) AST 470 180 /tank 98 82 0 Additional Tank ATI 96 /tank 82 0 Aboveground Storage Tank (Removal, Mod,or Inspect'n) ATR 109 /tank 82 0 Underground Storage Tank (Installation Inspection) NI 878 /tank 82 0 Underground Storage Tank ( Modification) MOD 878 /site 82 Underground Storage Tank (Min r Modification) MTM 167 /site 82 Underground Storage Tank (Removal) TR 573 /tank 84 0 Mandated UST Testing: Fuel Mont NOTE: $96 /hr for each type of t est/per ven if scheduled at the same time Cert/SB989 /Cath. Prot. site /per UST system 96 /hr (2 hrs minimum) _ $192 82 Oil well (Installation, Inspection, or re- inspection) X 96 /hr 82 Tent 96 /tent 84 0 After -hours inspection fee 121 /hr (2 hrs minimum) _ $242 0 Pyrotechnic (1 permit per event, 96 /hr during business hours) NOTE: After hours Pyrotechnic event plus an inspection fee of Py Inspection is @ $121 /hr 96 /hr + (5 hrs min standby fee /insp) _ $576 15 hrs min standby fee Ins = 605 84 0 Re- Inspection /Follow -up Inspection 96 /hr 84 84 84 84 0 Portable LPG (Propane): # of Cages? 96 /hr 0 Explosive Storage I 266 0 Copying & File Research (File Research fee $50 /hr) 0.25 /page 0 Miscellaneous 84 rn'W)l /Da AC /I 1\ US=