HomeMy WebLinkAbout2508 MEANY AVENUEft. -n ALARMS SPRNKLER SYSTEMS AST UST
Permit No. Permit No. Permit No. Permit No. Permit No. Permit No.
File Number:
Date Received:
35 -6 /el Address: 7 - 'E>
Bakersfield, CA 933
Business Name:
Other:
Comments: V'3 , S ` .
1.
2.
3.
4.
BR9 I CYMN LOG
Date Time
Signature
SYSTEM: BUILDING SQUARE FEET:
New Mod.
Commercial Hood System Building Sq. Feet:
Fire Alarm System Calculation Bldg. Sq. Ft:
Fire Sprinkler System
Gd' Aboveground Storage Tank
Underground Storage Tank
minor
modification Underground Storage Tank
removal Underground Storage Tank
Other:
Comments: V'3 , S ` .
1.
2.
3.
4.
BR9 I CYMN LOG
Date Time
Signature
ABOVEGROUND STORAGE TANK
GUIDELINES FOR PERMIT TO INSTALL /REMOVE AST
FOR DISPENSING OF FLAMMABLE OR COMBUSTIBLE
LIQUIDS AND CONDITIONS FOR CLOSURE, EXCAVATION,
REMOVAL & DISPOSAL, SOIL SAMPLING, PRELIMINARY
SITE ASSESSMENTS
13 A I S P It
f /RS:
ARrm , f
BAKERSFIELD FIRE DEPARTMENT
Prevention Services
2101 H Street
Bakersfield, CA 93301
Phone: 661-326-3979 . Fax: 661-852-2171
Page 2 of 2
GUIDELINES FOR PERMIT TO INSTALL AN AST
FOR DISPENSING OF PLAMMABLE OR COMBUSTIBLE LIQUIDS
1. Any aboveground storage tank installed within the City of Bakersfield for the purpose of Dispensing motor vehicle fuels must meet the
requirements of Section 2206.2.3 (1) of the California Fire Code, 2007 Edition and Bakersfield Municipal Code.
2. The tank sizes shall not exceed a capacity of 12,000 gallons individual or 48,000 gallons aggregate.
3. Any aboveground storage of petroleum with a cumulative capacity of more than 1,320 gallon must complete a Spill Prevention, Control
and Countermeasure (SPCC) Plan, per California Health & Safety Code Division 20 Chapter 6.67. A copy of this plan must be submitted
to the Bakersfield Fire Department Office of Prevention Services located at 2101 H Street, Bakersfield, CA 93301 and can be reached at
661 - 326 -3979.
APPLICATION PROCESS
1. Provide two sets of a plot plan for the facility. This plan must include location of property lines, all buildings and openings to each building
i.e., windows, doors, vents, etc.), nearest road or intersection, all tanks piping, any fixed source of ignition (i.e., water heaters, forced
air, AC units, etc.), all foundations, and equipment to be installed.
2. Construction details of tank pad seismic straps or fixtures, and crash posts.
3. Certification by the manufacturer that the tank meets the applicable codes.
4. Identification of the material to be stored in the aboveground storage tank.
5. Building permits for all reinforced concrete and electrical work must be obtained at the Bakersfield City Building Department located at
1715 Truxtun Avenue, Bakersfield, CA 661 -326 -3720. Construction cannot begin without their approved permit.
6. Complete any necessary application for the Air Pollution Control District for any storage or dispensing of gasoline or aviation fuel.
7. Applications must be fully completed or they will be returned - no exceptions.
8. Permit fee must be submitted with the application or the application will not be processed.
9. A final inspection must be completed before AST system is operational. This is to ensure compliance with the UFC regarding placement of
placards, and where applicable, the testing of emergency shut -off device, and overfill /overspill.
GUIDELINES FOR PERwIIT TO REMOVE AN AST
1. Tanks may not be removed without an inspector present.
2. Tanks shall be either decontaminated or transported as hazardous waste.
3. A Hazardous Waste manifest will accompany either the rinseate or the tank and shall be present on site and presented upon request.
4. The interior of tanks being transported not as hazardous waste (decontaminated) shall have a lower explosive limit (LEL) of no greater
than 5 percent immediately following cleaning and prior to the introduction of carbon dioxide (CO2).
5. The contractor shall certify on the inspection form that the cleaning process was properly conducted and the LEL results did not exceed 5
percent.
6. The decontaminated tank shall be inerted with the introduction of CO2, in the form of dry ice or from canisters.
7. A rate of 20 pounds of dry ice to 1,000 gallons of tank capacity, or the corresponding weight of CO2.
8. If canisters are used, they shall be bonded to the tanks.
9. A receipt for the CO2 shall remain on site and presented upon request.
10. Prior to the removal of a decontaminated tank the LEL level will be no greater than 5 percent and the oxygen level will be no grater than
9 percent.
SOIL SAMPLING/ PRELIMINARY SITE ASSESSMENT
1. Soil samples shall be obtained under the direction of a professional engineer, geologist, or authorized representative of a State - approved
laboratory.
2. Samples shall be collected, at a minimum, from depths of 2 and 6 feet below the tank bottom, dispensers, and product lines and from the
following locations (unless waived by the local agency inspector on site):
A. From the center of the tank.
B. Below all dispensers.
C. Piping - every 20 feet and /or at connections, joints, bends, etc.
3. Any area of obvious contamination of likely areas of contamination may be required to be sampled.
4. All samples shall be analyzed by a State - certified laboratory.
5. Soil samples shall be analyzed for all known and suspected substances to have been stored in the tank. Additionally, methyl tertiary butyl
ether (MTBE) shall be analyzed in all soil samples taken from beneath tank systems which contained any motor vehicle fuel.
6. All samples will be accompanied by a Chain -of- Custody sheet.
7. A soil sample report/preliminary assessment shall be submitted to the Office of Prevention Services within 5 days after results have been
received and shall contain at a minimum the following information.
A. Name and location of where tanks were disposed.
B. Name and location of where rinseate was disposed.
C. A signed copy of the Hazardous Waste Manifest.
D. A tank disposal receipt from the scraping facility.
E. Copies of all lab data sheets and Chain -of- Custody documentation.
F. A plot plan showing the location of buildings, tanks, piping runs, dispensers, and ALL SAMPLE LOCATIONS WITH CORRESPONDING I.D.
NUMBERS AND DEPTHS.
FD2081 (Rev 05/10)
In'
qt
errstat 1 "and
6501 FrOvale Ave., Bakersfield, CA 93308
Randall Bergquist
P.L.S. 5880
Office: (661) 399 -9000 Mobile: (661) 808 -5997
Fax: (661) 399 -9191 rabergq@gmail.com
i
ro
w A
TRANSMITTAL
Interstate Land Company
6501 Fruitvale Avenue Bakersrield, CA 93308
Phone 661 - 399 -9000 Fax 661 - 399 -9191
TO: CITY OF BAKERSFIELD FIRE DEPT. DATE: 07/21/10
HSTREET
BAKERSFIELD, CA 93301
ATTENTION: DAVE WEIRATHER
PROJECT: RIVERLAKES SURGERY CENTER
WE TRANSMIT: X ORIGINALS K]COPIES DISKETTE MAPS
F-JBLUELINES K]DOCUMENTS APPLICATIONS CHECK
VIA: QDELIVERY AIRBORNE F-]CA OVERNIGHT
MAIL El UPS OTHER
FOR YOUR: USE FILES SIGNATURE
XAPPROVAL X REVIEW AND INFORMATION
COMMENT
QUANTITY DESCRIPTION
1 ABOVE GROUND FUEL TANK PERMIT REQUEST
1 CHECK FOR $180
1 EA VARIOUS INFORMATION ON GENERATOR
COMMENTS:
PLEASE LET ME KNOW IF YOU NEED ANYTHING ELSE
THANK YOU
CC SINCERELY,
RANDALL BERGQUIST
PLS 5880 EXP/ 12/31/10
rabergq(a)gmail.com
ABOVEGROUND STORAGE TANK
INSTALL REMOVE
PERMIT #
BAKERSFIELD FIRE DEPARTMENT
Prevention Services
101 H Street
Bakersfield, CA 93301
Phone: 661-326-3979 • Fax: 661-852-2171
Page 1 of 2
FACILITY NAME
ADDRESS
75oe> - (3 GA r-5-eS l 1> C•A
OPERATOR NAME
C10 m H I ls U.3 C-
PERMIT TO OPERATE #
OWNER NAME
PAVI'D
OF TANKS TO BE INSTALLED /REMOVED
COMM105, 2 -P(E5E'L- 170 GAL.
NAME OF COMPANY INSTALLING AND/OR REMOVING TANK
c7'0r-1LA6-4'T' E=—LeCTTZ4CAL, CUIMKIrJS Lje7 r
MAILING ADDRESS
P.O. go c 61-7016
NAME & PHONE # OF CONTACT PERSON
L)pq(zp- 661 31 5 6) 0
DATE & TIME TANK IS TO BE INSTALLED /REMOVED
L. 2i4 2-0 10
SIGNATURE O PP CANT DATE
Ir L 200
APPROZ,..' I DATE
FD2081 (Rev 05/10)
m
0