Loading...
HomeMy WebLinkAboutFMC 2011MONITORING SYSTEM CERTIFICATION For Use By All Jurisdictions Within the State ofCalifornia Authority Cited: Chapter 6 7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code ofRegulations This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner /operator. The owner /operator must submit a copy ofthis form to the local agency regulating UST systems within 30 days of this date. A. General Information Facility Name: Arco AM PM Bldg. No.: Site Address: 900 Monterey Street City: Bakersfield Zip: 93305 Facility Contact Person: Alondra Hemandez Contact Phone No.: 661 - 835 -8044 Make/Model of Monitoring System: Veeder Root TLS 350 B. Inventoryy of Equipment Tested /CertifiedChecktheappropriateboxestoIndicatespecificequipmentInspected/serviced: Date ofTesting/Servicing: 9/6/2011 Tank ID: 12000 gal. Regular Master Tank ID: 12000 gal. Regular Slave x] In -Tank Gauging Probe. Model: 847390 -107 x] In -Tank Gauging Probe. Model: 847390 -107 x] Annular Space or Vault Probe. Model: 794390 -420 X] Annular Space or Vault Sensor. Model: 794390 -420 x] Piping Sump / Trench Sensor(s). Model: 794380 -208 x] Piping Sump / Trench Sensor(s). Model: 794380 -208 X] Fill Sump Sensor(s) Model: 794380 -208 Fill Sump Sensor(s). Model: 794380 -208 Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: N Electronic Line Leak Detector. Model: Red Jacket g Electronic Line Leak Detector. Model: Red Jacket x] Tank Overfill / High Level Sensor. Model: 847390 -107 Tank Overfill / High Leval Sensor. Model: Other (specify equip. type and model in Sec. E on Pg. 2) Other (specify equip. type and model in Sec. E on Pg. 2) Tank ID: 12000 gal. Super Tank ID: x] In -Tank Gauging Probe. Model: 847390-107 In -Tank Gauging Probe. Model: x] Annular Space or Vault Sensor. Mode1:794390 -420 Annular Space or Vault Sensor. Model: x] Piping Sump / Trench Sensor(s). Model: 794380 -208 Piping Sump / Trench Sensor(s). Model: x] Fill Sump Sensors(s). Model: 794380 -208 Fill Sump Sensor(s). Model: x1 Mechanical Line Leak Decector. . Model: FE Petro Mechanical Line Leak Detector. Model: Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: x] Tank Overfill / High Level Sensor. Model: 847390 -107 1 Tank Overfill / High Level Sensor. Model: El Other (specify equip. type and model in Sec. E on Pg. 2) Other (specify equip. typs and model in Sec. E on Pg. 2) Dispenser ID: 1& 2 Dispenser ID: _3 & 4 c Dispenser Containment Sensor(s). Model: 794380 -208 x] Dispenser Containment Sensor(s). Model: 794380 -208 7 Shear Valve(s). x] Shear Valve(s). Dispenser Containment Float(s) and Chain(s). Dispenser Containment Float(s) and Chain(s) Dispenser ID: 5 & 6 Dispenser ID: 7 & 8 x] Dispenser Containment Sensor(s). Model: 794380 -208 X] Dispenser Containment Sensor(s). Model: 794380 -208 x] Shear Valve(s). X] Shear Valve(s). Dispenser Containment Float(s) and Chains(s). Dispenser Containment Float(s) and Chain(s). Dispenser ID: 9 & 10 Dispenser ID: 11 & 12 X] Dispenser Containment Sensor(s). Model: 794380 -208 x] Dispenser Containment Sensor(s). Model: 794380 -208 x] Shear Valve(s). x] Shear Valve(s). Dispenser Containment Float(s) and Chain(s) Dispenser Containment Float(s) and Chain(s). Ifthe facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. C. Certification - I certify that the equipment identified in this document was inspected /services in accordance with the manufacturers' guidlines. Attached to this Certification is information (e.g. manufacturers' checklist) necessary to varify that this information is correct and a plot plan showing the layout of monitoring equipment. For equipment capable of generating such reports, I have attached a copy of the report; (check all that apply) x Syyste Set -up ( Alar ory report Technician Name (print): Bryan A Self Signature: Certification No: B37501 License No: 804904 Testing Company Name: Confidence UST Services, Inc. Phone No: 800- 339 -9930 Site Address: 900 Monterey Street, Bakersfield, CA 93305 Date of Testing/Servicing: 91612011 D. Results of Testing /Servicing Software Version Installed: 331.01 Complete the following checklist: Lx] Yes No* Is the audible alarm operational? x Yes No* Is a Visua a arm operational? x Yes No* Were all sensors visually inspected, functionally tested, and confirmed operational? x I Yes No* Were all sensors installed at the lowest point of secondary containment and positioned so that other equipment will not interfere with their proper operation? Yes No* Ifalarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) Hx N/A operational? x Yes No* For pressurized piping systems, does the turbine automatically shut down if the piping secondary N/A containment monitoring system detects a leak, fails to operate, or is electrically disconnected? Ifyes: which sensors initate positive shut -down? [x] Sumparench Sensors [] Dispenser Containment Sensors Did you confirm positive shut -down due to leaks and sensor failure /disconnected? [X] Yes; No; X] Yes No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no r ] N/A mechanical overfill prevention valve is installed), is the overfill warning alarm visual and audible at the tank fill point(s) and operating properly? Ifso, at what percent oftank capasity does the alarm trigger? I 9p I % Yes* X] No Was any monitoring equipment replaced'? If Yes, identify specific sensors, probes, or other equipment replaced and list the manufacturer name and model for all replacement parts in Section E, below. Yes* U No Was liquid found inside any secondary containment systems designed as dry systems? Product; Water. Ifyes, describe causes in Section E, below. x Was monitoring system set -up reviewed to ensure proper settings? Attach set -up reports, if applicable. W yes No* Is all monitoring equipment operational per manufacturer's specifications? In Section E below, discribe how and when these deficiencies were or will be corrected. E. Comments: F. In -Tank Guaging / SIR Equipment: Check this box if tank guaging is used only for inventory control. Check this box if tank guaging or SIR equipment is installed. This section must be completed if in -tank guaging equipment is used to perform leak detection monitoring. the following checklist: U Yes No* Has all input wiring been inspected for proper enter and termination,including testing for ground faults? x Yes No* Were all tank guaging probes visually inspected for damage and residue buildup? x Yes No* Was accuracy of system product level readings tested? x Yes No* Was accuracy of system water level readings tested? Yes No* Were all probes reinstalled properly? xl x] Yes No* I Were all items on the equipment manufacturer's maintenance checklist completed? In the Section H, below, describe how and when these deficiencies were or will be corrected. G. Line Leak Detectors (LLD): Complete the following checklist: Check this box if LLD's are not installed. x] Yes No* For equip. start-up or annual equipment certification, was a leak simulated to varify LLD performance? Check all that apply) Simulated leak rate: [x]3 g.p.h.: 0.1 g.p.h.; 0.2 g.p.h.; x Yes No* Were all LLD's confirmed operational and accurate within regulatory requirments? x Yes No* Was the testing apparatus properly calibrated? es No For machanical LLD s, does the LLD restrict product flow n it detects a leak? N/A x] Yes No* For electronic LLD's, does the turbine automatically shut off if the LLD detects a leak? N/A x] Yes No* For electronic LLD's, does the turbine automatically shut off if any portion of the monitoring system is N/A disabled or disconnected? x] Yes No* For electronic LLD's, does the turbine automatically shut off if any portion of the monitoring system N/A malfunction or fails a test? U Yes No* For electronic LLD's, have all accessible wiring connections been visually inspected? N/A x Yes No Were all items on the equipment manufacturer's maintenance checklist completed? In the section H, below, describe how and when these deficiencies were or will be corrected. H. Comments: The Super has a FE Petro Mechanical LLD and both ofthe Regular have Red Jacket Electrical LLD's. ARCO 5526 900 MONTEREY ST BAI:ERSF I ELD•- CA93305 M 805 -861 -1972 - SEP 6 P011 12:40 PM SYSTEM - STATUS - REPORT - T 3:LOW PRODUCT ALARM INVENTORY REPORT I T I:UNLEADED SYPHON I VOLUME = 3268 GALS t ULLAGE = 8359 GALS 90% ULLAGE- 7196 GALS ! TC VOLUME - 3209 GALS HEIGHT = 30.32 INCHES WATER VOL - 0 GALS WATER = 0.00 INCHES TEMP = 85.4 DEC F T 2:UNLEADED MAIN VOLUME = 3454 GALS ULLAGE o 8.173 GALS 90%tULLAGE- 7010 GALS TC•- VOLUME - 3387 GALS HE;IGHT - 3i.52 INCHES WATER VOL m 0 GALS INTER - . 0.00 INCHES TEMP - 87.3 DEG F T.3:PREMIUM VollME,,,' - 1185 GALS UL:LAG ' - 10442 GALS 90P. ULLAGE- 9279 GALS TO VOLUME - 1160 GALS HEd4:3HT - 15.19 1 NCHES WATER VOL - 0 GALS WATER o 0.00 INCHES TEMP = 89.4 DEG F X x x r, A END * w x A% SOFTWARE REVISION LEVEL VERSION 331.01 SOFTWAREU 346331 -100 -B CREATED - 11.03.22.16.29 S- MODULEU 330160 -004 -a SYSTEM FEATURES: PERIODIC IN -TANK TESTS ANNUAL IN -TANK TESTS ISD/APM SYSTEM SETUP - - - - - - SEP 6. 2011 12:10 PM SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM' DATE /T I ME FORMAT MON DD YYYY HH:hIM:SS xM ARCO 5526 900 MONTEREY ST BAKERSFIELD.l;A93305 805 -861 -1972 SHIFT TIME 1 6:00 AM SHIFT TIME 2 DISABLED SHIFT TIME 3 DISABLED SHIFT TIME 4 DISABLED TANK PER TST NEEDED WRN DISABLED TANK ANN TST NEEDED WRN DISABLED LINE RE- ENABLE'METHOD PASS LINE TEST LINE PER TST NEEDED WRN DISABLED LINE ANN TST NEEDED WRN DISABLED PRINT TC VOLUMES ENABLED TEMP COMPENSATION VALUE (DEG F ): 60.0 STICK HEIGHT OFFSET D I,SABLED OLLAGE: 90% HE; H.- PROTOCOL DATA FORMAT IGHT DAYLIGHT SAVING TIME ENABLED START DATE APR WEEK 1 SUN START TIME 2:00 AM END DATE OCT WEEK 6 SUN END •T I ME 2:00 AM RE- DIRECT' LOCAL PRINTOUT' DISABLED EURO PROTOCOL PREFIX 9 SYSTEM SECURITY CODE : 000000 MAINTENANCE HISTORY DISABLED TANK CHART SECURITY DISABLED CUSTOM ALARMS DISABLED SERVICE NOTICE DISABLED ISO 3166 COUNTRY CODE: VAPOR MONITORING TYPE GARB ISD MASS /DENSITY DISABLED COMMUNICATIOI3 SL-TUP IN-TANK SETUP T 2: UNLEADED MA I N PRODLr;T CODE 2 PORT ShTfINi S: T 1:UNLEADED SYPHON THERMAL COEFF ;.QORI TANK DIAMETER 00 92.00 COMM BOARD : 1 ICEDIM PRODUCT CODE THERMAL COEFF :.000700 I TANK PROFILE FULL VOL 4 PTS 11627RS-232 SECURITY CODE DISABLED TANK DIAMETER TANK PROFILE 92.00 q pT$ 69.0 IJNGH VOL 9438 FULL VOL : 11627 46.0 INCH VOL 23.0 INCH VOL 5814 2190 BOARD 5 <RS -4851CAUS 69.0 INCH VOL 9438 BAUD RATE 9600 46.0 INCH VOL 5814 EVEN 23.0 [NCH VOL 2190 FLOAT SIZE: il.0 IN. OP BIT DATA LENG'fH : 1 DATA RS -232 SECURITY FLOAT SIZE: q,0 N, WATER,WARNiNG HIGH WATER LIMIT: 2.0 3.0CODE : DISABLED WATER WARNING 2.0 WATER ALARM FILTER: LOW COMM WARD : 6 IRS -2321BAUDRATE HIGH WATER LIMIT: WATER ALARM FILTER: 3.0 LOW MAX OR LABEL VOL: 11627 9600 OVERFILL LIMIT : 90`4 PARITY :NONE STOP BIT I STOP MAX OR LABEL VOL: 11627 HIGH PRODUCT t0464 95s: DATA LEND —TH: 8 DATA OVERFILL LIMIT • 90%c 11045 RS -232 SECURITY CORE',.: DISABLED HIGH PRODUCT 464J04b4 DELIVERY LIMIT : 4 10% 11045 4 ^ It 62 DELIVERY LIMIT : Im., LOW PRODUCT 1250 AUTO TkANSM { T SETT ! PIG. , : 1162 LEAK ALARM LIMIT: 99 AUTO LEAK ALARM LIMIT LOW PRODUCT 1250 SUDDEN LOSS LIMPS': TANK TILT 99 2.00 DISABLED AUTO HIGH WATER LIMIT LEAK ALARM LIMIT: SUDDEN LOSS LIMIT: 99 99 PROBE OFFSET 0.00 DISABLED TANK TILT 2.00 AUTO OVERFILL LIMIT PROBE OFFSETOFFSET 0. SIPHON MANIFOLDED TANKSDISABLEDTO: NONE AUTO LOW PRODUCTDISABLED SIPHON MANIFOLDED TANKS MANIFOLDED TANKS AUTO THEFT LIMIT TO: NONE TO: NONE DISABLED LINE MANIFOLDED TANKS AUTO DELIVERY START TO: NONE LEAK M1I4 PERIODIC: 3rf4 DISABLED 3488F{I)7O DELIVERY ENDDISABLED 3LEHKMINDER1OLI 30 % 3488 LEAK MIN ANNUAL 30% AUTO EXTERNAL INPUT ON 3488DISABLED AUTO EXTERNAL INPUT OFF LEAK MIN ANNUAL : 30'4 DISABLED x488 PERIODIC TEST TYPEAUTOSENSORFUELALARMSTANDARDDISABLED AUTO SENSOR WATER ALAPPI PERIODIC TEST TYPE ANNUAL TEST FAILDISABLEDSTANDARDALARMDISABLEDAUTOSENSOROUTALARMDISABLEDAINUAITESTFAILL ALARM DISABLED PERIODIC TEST FAILPERIODIC DISABLED PERIODIC TEST FAIL GROSS TEST FAILALARMDISABLEDALARM DISABLED GROSS TEST FAIL ALARM D 1 SABL.ED ANN T>rST AVERR -,ING: OFF PER TEST AVEP.AG I DG.: OFF R5 -232 END OF MEfr,3AGEDISABLED ANN TEST AVERHGI (Vr; PER TEST AVERAGING: OFF OFF TANK ' TEST 140T I FY : OFF TANK TEST NOTIFY: OFF TNK TST SIPHON BREAK:OFF TNK TST SIPHON BREAK:OFF DELIVERY DELAY PUMP THRESHOLD 5 MIN 10.00'x: DELI'VERY.DELAY : 5 MIN PUMP THRESHOLD : 10.007: L 7:PREMIUM ANNULAR T 3:PREMIUM LEAK TEST METHOD TRI - STATE,(SINGLE FLOAT) PRODUCT CODE 3 CATEGORY ANNULAR SPACE THERMAL COEFF :.000700 TEST ON DATE,: ALL TANK TANK DIAMETER 92.00 14AR22. 2011 TANK PROFILE 4 PTS START TIME : DISABLED FULL VOL : 11627 TEST RATE :0.20 GAL /HR L B:PREMIUI.1 FILL SUMP 69.0 INCH VOL : 9438 DURATION 2 HOURS TRJ -STATE (SINGLE FLOAT) 46.0 INCH VOL 5814 CATEGORY : OTHER :SENSORS 23.0 INCH VOL 2190 TST EARLY STOP:DISABLED LEAK TEST REPORT FORMAT FLOAT SIZE: 4.0 IN. NORMAL TRI RB I NE SUMPS7TEUSI WATER WARNING 2.0 CATEC'.QRY : -STP SUMP HIGH WATER LIMIT: 3.0 WATER ALARM FILTER: LOW 1-10:1 -2 UDC MAX OR LABEL VOL: 11627 TRI -STATE (SINGLE FLOAT) OVERFILL LIMIT 90% CATEGORY : DISPENSER PAN 10464 HIGH PRODUCT 95% 11045 DELIVERY LIMIT 10% 1-11:3-4 UDC 1 162 L I WU I D SENSOR `:ETUP TRI -STATE (S i NCLE -FLOAT) CATEGORY : DISPENSER ,PAN LOW PRODUCT 1500 LEAK ALARM LIMIT: 99 L 1:FINNULAR S`:PF101 SUDDEN LOSS LIMIT: 99 TRI -STATE :(SINGLE FLOAT)' TANK TILT 3.00 CATEGORY ANNULAR SPACE L12:5 -6 UDC PROBE OFFSET 0.00 TR,I -STATE (SINGLE FLOAT) CATEGORY : DISPENSER PAN SIPHON MANIFOLDED TANKS L 2 :SYPHON FILL SL41P TO: NONE TRI -STATE (SINGLE FLOAT) LINE MANIFOLDED TANI:S CATEGORY ; OTHER SENSORS L13:7-0 UDC Td: NONE TRI -STATE !SINGLE FLOAT) CATEGORY : DISPENSER PAN LEAK MIN PERIODIC,: 30% L 3:SYPHON TURBINE SUMP 3488 TRI -STATE (91,NGLE FLOAT) CATEGORY : PIPINt. SUMP L.14:9 -10 UDC LEAK Ihtl N ANNUAL : 30% TR 1•- )STATE (.SINGLE FLOAT) 3488 CATEGORY : DISPENSER PAN L 4:ANNULAR MAIN UNL TR 1 -STATE (S 1 h1GLE FLOAT) PERIODIC TEST 'TYPE CATEGORY ANNULAR :SPACE STANDARD L15:11 -12 UDC, TRI -STATE (S1 WLE FLOAT) ANNUAL TEST FAIL CATEGORY DISPENSER PAN ALARM DISABLED L 5 : MA 6N• UNL FILL TRI-STATE FLOAT) PERIODIC TEST FAIL. SINGLE• CATEGORY OTHER SENSORS ALARM DISABLED GROSS TEST FAIL ALARM DISABLED L 6:MAlN UNL TURBINE TRI- STATE (SINGLE FLOAT) ANN TEST AVERAGING: OFF CATEGORY : STP SUMP PER TEST AVERAGING: OFF TANK TEST NOTIFY: OFF TNK TST SIPHON BREAK:OFF DELIVERY DELAY 5 MIN PUMP THRESHOLD 10.00k OUTPUT RELAY SETUP EVR /ISD SETUP R I:UNLEADED SHUTDOWN EVR TYPE: BALANCETYPE: STANDARD NORMALLY CLOSED BALANCE NOZZLE TYPE VST TANK 0: 2 SMARTSENSOR SETUP y - - - VAPOR PROCESSOR TYPE VEEDER -ROOT POLISHER N -TANK ALARMS 3 1 : 1 -2 AFM CATEGORY AIR FLOW PIETERALL:LEAK ALARM ANALYS -I'S TIMES LIQUID fiENSOk ALMS 2:3-4 AFM T IME't y :'AM L !:FUEL ALARM CATEGORY AIR FLOW METERCATEGORY DELAY MINUTES: i L 2:FUEL ALARM s 3:5 -6 AFML3:FUEL ALARM CATEGORY AIR FLOW METER ACCEPT HIGH ORVR.' L 4:FUEL ALARM DISABLEDL5:FUEL ALARM s 4 :7 -8 AFML6:FUEL ALARM LIO:FUEL ALARM CATEGORY A,IR FLOW METER ISD HOSE TABLE LII:FUEL ALARM ID FP FL HL AA RR 12:FUEL ALARM • LLALARM s 5:9 -10 AFM CATEGORY AIR FLOW METER 00 01• 02 Ol 02FUELALARM01 02 01 02 02 01 02L14:FUEL ALARM s 6:11 -12 AFM 03 02 03 02 02 02L15:FUEL ALARMFUELA CATEGORY AIR FLOW METER 0.4 03 04 02, 02 02 AL5 : OUT aLAkhl 05' 04 05 02 03 02ALL:SHORT ALARM s B:ATMP - _ 06, -06 06 02 03 02 CATEGORY ATM P SENSOR 07 06 07 02 04 02ISDSITEALARMS080708020402ISDGROSSPRESFAIL UVAPORISDDEGRDPEESFAILCATEGORY PRESSURE 110 09 10 02 05 02ISDVAPORLEAKFAIL1110II020602ISDVPs16:CCVP 12 11 12 02 OG 02STATUSSFAISDVPSTATUSFAILCATEGORYVAPORVALVEISDSETUPFAIL SD SENSOR OUT FAIL ISD AIRFLOW METER MAP SD HOSE ALARMS ID SERIAL NUM LABEL ALL :FLOW COLLECT FAIL 1 36585 1 -2 AFM R 2:PREM1UM SHUTDOWN 2 52453 3 -4 AFM 3 38276 5 -6 AFMTYPE: STANDARU 4 53958 7 -8 AFM NORMALLY CLOSED 5 36669 9 -10 AFM 6 36796 11 -12 AFM TANK 0: 3 ISD FUEL GRADE HOSE MAP LIQUID SENSOR ALMf3 1 2 3 4 FP MHH MHH AAL7 :FUEL ALARM L 8:FUEL ALARM IHHH -MHH 00 401 901 501 U U IL9:FUEL ALARM 01 402 902 502 U U 1LIO :FUEL ALARM 02 403 903 503 U U 2LII:FUEL ALARM 03 404 904 504 U U 2L12:FUEL ALARM 04 905 a5 5 U U050405 3L13:FUEL ALARM 05 405 505 U U 3L14:FUEL ALARM 06 407 907 507 U U 4L15:FUEL 07 408 908 508 U U 4OUTALL:SENSOR OUT AL!~P.MT 0808 409 909 509 U U 5ALL:SHORT ALARM 410 910 510 U 11 5 ISD SITE ALARMS 10 411 911 511 U U 11 412 912 512 U U 6 6ISDGROSSPRESSFAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL LABEL TABLE' ISD VP PRES FAIL ISD VP STATUS FAIL 1: UNASSIGNEDISDSETUPFAIL ISD BENSOR OUT FAIL 2: BLENDS 3: REGULAR ISD HOSE ALARMS 4: MID GRADE 5: PREMIUMALL:FLOW COLLECT FAIL 6: GOLD R 3:OVERFILL ALARM 7: BRONZE 8: SILVERTYPE: 9: BLEND2STANDARD10: BLEND4NORMALLYOPEN TANK 0: NONE I N -TANK ALARMS ALL:OVERFILL ALARM PMC SETUP PMC VERSION: 01.04 VAPOR PROCESSOR TYPE VEEDEP. —ROOT POLISHER ALARM H1STORV REPORT SYSTIII ALARM PAPER OUT SEP 3. 2011 8:16 PM PRINTER ERROR SEP 3, 2011 8:16 PM x x x+ r END x xxpi ALARM HIST0RV REPORT I N —TANI: ALARM T 1:UNLEADED SYPHON LOW PRODUCT ALARM SEP 2. 2011 3:99 PM AUG 31' - 2011 11,: 5$ All AUG 29,: 20, 1 9 :013 AM 1 NVAL I D FUEL LEk /lEI. AUG 12. 2011 7:34 PM AUG G. 2011 2125 PM AUG 2. 2011 6:05 PM PROBE OUT JUL 6. 2011 9:02 AM DELIVERY NEEDED SEP 2, 2011 4 :23 PM AUG 31. 2011 12:43 Phl AUG 29. 2011 9:46 AM M; i x 0' x END X x :4 .A A, ALARM HISTORY REPORT IN—TANK ALARM — T 2:UNLEADED MAIN LOW PRODUCT ALARM S!"P 2: 20 t' 1 a : 27 PM AUG 31. 201'1 1:12 PM AUG 29. 2011 10:12 AM INVALID FUEI. LEVEL AUG 12. 2011 7:58 PM AUG 6, 2011 3:09 Phi AUG 2, 2011 6 :45 PM PROBE OUT JUL 6. 2011 10:13 AM JUL 6. 2011 10:11 AM JUL 6. 2011 9 :22 AM DELIVERY NEEDED SEP 2. 2011 4 :57 PM AUG 29. 2011 11:06 AM AUG'26. 2011 9:41 PM kxXxV END xr Axw 6 ALART9 HISTORY REPORT IN —TANK, ALARM T 3:PREMlUM 1:01+1 PRODLI: T ALARM SEP 5. 2011 12 :56 PM AUG 31, 2011 6:08 PM AUG 29, 2011 5:56 AM INVALID FUEL LEVEL SEP 2. 2011 10:05 AM AUG 12, 2011 11:26 AM AUG 2. 2011 6 :13 PIl DELIVERY NEEDED SEP 3. 2011 8:37 PM SEP 1, 2011 2:19 PM AUG 24. 2011 8 :28 PM xxrixEND;cRxr ALARM HISTORY REPORT SENSOR ALARM - -- -- L 1:ANNULAR SYPHON ANNULAR SPACE SETUP DATA WARNING MAR 22, 2011 8:03 AM k m w x X END JA x x k ALARM HISTORY REPORT SENSOR ALARM _ - -- L 2 : SYPHON FILL SUt °1P OTHER SENSORS SETUP DATA WARNING MAR 22,. 2011 8:03 AM x x x x x EIVD A h 4 :, , i ALARM HISTORY REPORT SEWPOR ALARIN - - - -- L 3:SYPHON TURBINE SUMP PIPING SUMP SETUP DATA WARNING MAR 22, 2011 8:03 AM A x A* w END N x A ;i x ALARM HISTORY REPORT SENSOR ALARM - - - -- L 4 :ANNULAR'MAIN UNL ANNULAR SPACE SETUP DATA WARNING MAR 22. 2011 8:03 11M ALARM HISTOW, REPORT SENSOR ALARM - - - -- L 5:MAIN UNL FILL OTHER SENSORS SETUP DATA WARNING MAR 22. 2011 8:03 AM A x x x x END K x is [ w ALARM HISTORY REPORT SENSOR ALARM --- -- L 6:11AIN UNL TURBINE STP SUMP SETUP DATA WARNING MAR 22. 2011 8:03 AM X x x x x END K A x x x ALARM HISTORY REPORT SENSOR ALARM - - - -- L 7:PREMIUM ANNULAR ANNULAR SPACE SETUP DATA WARNING MAR 22. 2011 8:03 AM a ALARM HISTORY REPORT SENSOR ALARM - -- -- L 8 :,PREM.1 Uhl FILL SUMP OTHER SENSORS SETUP DATA WARNING MAR 22. 2011 8:03 AM R xhxxEND. - W W W.1r ALARM HISTORY REPORT SENSOR HL(iRM - - - -- L S :PREMIUM TURBI.NE SUMP STP SUMP SETUP DATA WARNING MAR 22, 2011 8:03 AM x x x X END k ALARM HISTORY REPORT SENSOR ALARM --- -- L10:I -2 UDC, DISPENSER PAN SETUP DATA WARNING MAR 22, 2011 8:03 All k END w x x w x ii ii r if x END x "r, k 3ikxxxkENDxxxxx ALARM HISTORY REPORT SENSOR ALARM - -- L11:3 -a UDC: DISPENSER PAN SETUP DATA WARNING MAR 22. 2011 8:03 AM V 9 x r t END A. x X x x ALARM HISTORY REPORT SENSOR ALMR11 -_ - -- L12:5-6 UDC DISPENSER PAN SETUP DATA WARNI W-'- MAR 22. 2011 9:03 AM x x x x k END A A A x if ALARM HISTORY REPORT SENSOR ALARM - - - -- 1-13:7-8 UDC DISPENSER PAN SETUP DATA WARN I W-; MAR 22. 2011 8:03 AM x is N x X END W x k A x ALARM HISTORY REPORT SENSOR.ALARM -- - -- L1 1: -I0 UDC D1 S1;ENSER PAN SETUP DATA WARNING MAR 22, 2011 8:03 AM x x w w x END 9 X w x x ALAR11 HISTORY REPORT SENSOR ALARM -- - -- L15:11 -12 UDC DISPENSER PAN SETUP DATA WARNING MAR 22, 2011 8:03 AM x X x K k END x x W w w T 3:LOW PRODUCT ALARM T 3:INVALID FUEL LEVEL. T 3:DELIVERY NEEDEDI r ARCO 5526 900 MONTEREY ST WEPSI=IELD.CA93305 805 - 861-1972 SEP 6. 2011 12:50 PM I SYSTEM STATUS REPORT T 3:LOW PRODUCT ALARM T 3:INVALID ,FUEL LEVEL T 3 : DELIVER` ' NEEDED ARCO- 5526 900 MONTEREY ST BAICERSFIELD.CA93305 805 -861 - 1972` SEP 6. 2011 12:50 PM SYSTEM STATUS REPORT T 3:LOW PRODUCT ALARM T 3:INVALID FUEL LEVEL T 3:DELIVERY NEEDED ARCO 5526 900 MONTEREY ST i EAKERSFIELD.CA93305 805 - 861 -1972 SEP 6. 2011 12:50 PM SYSTEM STATUS REPORT T 3:LOW PRODUCT ALARM T 3:INVALID FUEL LEVEL 1 3:DELIVERY NEEDED'' IN -TANK ALARM - - - -- T 3:PREMIUM HIGH PRODUCT ALARM SEP 6.. 2011 12:51 PM 1N -TANX ALARM -- - -- T 3:PREMIUM LOW TEMP WARNING SEP 6. 2011 12:51 PM IN-TAN)" ALARM - --- T 2 :UNLEADED MAIN LOW PRODUCT ALARM SEP 6. 2011 12:51 PM IN -TANK ALARM - -- -- T 2 :UNLEADED MAIN DELIVERY NEEDED SEP 6. 2011 12:51 PM 1N -TANK ALARM - - - -- T 2 :UNLEADED MAIN LOW TEMP WARNING SEP 6. 2011 12:52 PM IN -TANK ALARM - - - -- T I :UNLEADED SYPHON LOW PRODUCT ALARM SEP 6. 2011 12:52 PM IN -TANK ALARM - - - -- T I:UNLEADED SYPHON DELIVERY NEEDEU SEP 6. 2011 12:52 PM IN -TANK ALARM - - - -- T 2:UNLEADED MAIN OVERFILL ALARM SEP 6. 2011 12 :53 PM IN -TANK ALARM - - - -- T !:UNLEADED SYPHON INVALID FUEL LEVEL SEP 6. 2011 12:54 PM ARCO 5526 900 MONTEREY ST BAKERSFIELD.C493305 805 -861 -1972 SEP 6, 2011 12:56 PM SYSTEM STATUS REPORT T 2 :OVERFILL ALARM T 3:HIGH PRODUCT Ni-ARM m ARCO 5526 900 MONTEREY ST BAKERSFIELD,CA93305 805 -861 -1972 SEP 6. 2011 12:56 PM SYSTEM STATUS REPORT T 2:OVERFILL ALARM T 3:HIGH PRODXT ALARM ARCO 55'26 900 MONTEREY ST BAKERSFIELD.CA93305 805 -861 -1972 SEP 6, 2011 12:56 PM SYSTEM STATUS REPORT T 2 :OVERF 1 LL ALiiP.M T 3: H 1 GH PRODLY T ALARM ALARM HISTOk1 REPORT SENSOR ALARM - -- - 1-15:11-12 UDC DISPEK9ER PAN SETUP DATA WARNING MAR 22, 2011 8:03 AM A. ;i x x x END x* A x W T 2:UNLEADED MAIN INVENTORY INCREASE INCREASE START SEP 6. 2011 12:51 PM VOLUME = 1131 GALS HEIGHT - 14.72 INCHES WATER . 0.00 INCHES TEMP = 87.3 DEC F INCREASE END SEP 6, 2011 12:58 PIN VOLUME a 10670 GALS HEIGHT d 78.82 INCHES WATER = 0.00 INCHES TEMP . 90.2 DEG F GROSS INCREASE= 9539 TC PIET INCREASE- 9335 T I* UNLEADED SYPHON INVENTORY INCREASE INCREASE START SEP 6. 2011 12:52 PM VOLUME = IOV9 GALS HEIGHT - 14.44 INCHES WATER = 0.00 INCHES TEMP = 85.4 DEG F INCREASE END SEP 6. 2011 1:00 P11 VOLUME a 9527 GALS HEIGHT = 69.64 INCHES WATER = O.UO INCHES TEMP - 90.8 DEG F ARCO 5526 900 MONTEREY ST BAXERSFIELD.CA93305 805- 861 -1972 SEP 6. 2011 1:19 PM SYSTEPI STATUS REPURT T 3:HIGH PRODUCT ALARM SENSOR ALARM L 3:SYPHON TURBINE SUMP PIPIPN3 SUMP FUEL ALARM SEP 6. 2011 .1:21 PM SENSOR ALARM L 6 : KA I N UNL TURBINE STP SUMP FUEL ALARM SEP 6. 2011 1:23 PIN SENSOR ALARM L 9:PREMIUM TURBINE SUMP STP SUMP FUEL ALARM SEP 6, 2011 1:24 PM ARCO 5526 900 MONTEREY ST BAKERSFI ELI) .CA93305 805-861 -1972 SEP 6. 2011 1:24 PM SYSTEM STATUS REPORT T 3: H IGHPRODM-r ALARM L 3:FUEL ALARM L 6:FUEL ALARM L 9:FUEL ALARM INVENTORY REPORT T I:UNLEADED SYPHON VOLUME = 9528 GALS ULLAGE a 2099 GALS 90% ULLAGE- 936 GALS TO VOLUME - 9209 GALS HEIGHT - 69.65 INCHES WATER VOL e 0 GALS WATER = 0.00 INCHES TEMP o 107.8 DEG F T 2:UNLEADED MAIN VOLUME = 10671 GALS ULLAGE - 956 GALS 90 ULLAGE- 0 GALS TO VOLUME - 10314 GALS HEIGHT = 78.93 INCHES WAFER VOL = 0 GALS WATER = 0.00 INCHES TEMP a 107.7 DEG F T 3 :PREMIUM VOLUME 11281 GALS ULLAGE = 346 GAL..S 90s: ULLAGE- 0 GALS TO VOLUME = 10897 GALS HEIGHT = 85.25 INCHES WATER VOL - 15 GALS WATER - 0.95 INCHES TEMP = 108.4 DEG F GROSS INCREASE= 8428 TO NET INCREASE- 8242 x END i ARCO 5526 900 MONTEREY ST EAKERSFIELD•CA93305 805 -861 -1972 SEP 6. 2011 1:24 PM. SYSTEM STATUS•REPORT t 3:H1GH PRODUCT ALARM L 3:FUEL ALARM L 6:FUEL ALARM L 9:FUEL ALARM INVENTORY REPORT T I:UNLEADED SYPHON VOLUME - 9528 C;ALS ULLAGE - 2099 GALS 90% ULLAGE- 936 GALS TC VOLUME = 9209 GALS HEIGHT - 69.65 INCHES WATER VOL - 0 GALS WATER - 0.00 INCHES TEMP - 107.8 DEC F T 2:UNLEADED MAIN VOLUME = 10671 GALS ULLAGE = 956 GALS 90% ULLAGE- 0 GALS TC VOLUME = 10314 GALS HEIGHT = 78.83 INCHES WATER VOL 0 GALS WATER = 0.00 INCHES TEMP 107.7 DEC F T 3:PREMIUM VOLUME = 11281 GALS ULLAGE - 346 GALS 90% ULLAGE- 0 GALS TC VOLUME = 10897 GALS HEIGHT - 85.25 INCHES WATER VOL - 15 GALS WATER = 0.95 INCHES TEMP - 108.4 DEC F x x x x x Elgrl x A x x x ARCO 5526 900 MONTEREY ST BAKERSFIELD.CA93305 805 -861 -1972 SEP 6, 2011 1:24 PM SYSTEM STATUS REPORT T 3:HIGH PRODUCT ALARM L 3:FUEL ALARM L 6:FUEL ALARM L 9:FUEL ALARM INVENTORY REPORT° T I:UNLEADED SYPHON VOLUME = 9528 GALS ULLAGE - 2099 GALS 909 ULLAGE- 936 GALS TO VOLUME - 9208 GALS HEIGHT - 69.65 INCHES WATER VOL - 0 GALS WATER - 0.00 INCHES TEMP - 107.8 DEC F T 2:UNLEADED MAIN VOLUME - 10671 GALS ULLAGE = 956 GALS 90% ULLAGE- 0 GALS TC VOLUME - 10314 GALS HEIGHT - 78.83 INCHES WATER VOL - 0 GALS WATER = 0.00 INCHES TEMP - 107.7 DEG F T 3:PREMIUM VOLUME = 11280 GALS ULLA:.E = 347 GALS 90% ULLAGE- 0 GALS TO VOLUME - 10897 GALS HEIGHT = 85.24 INCHES WATER VOL - 15 GALS WATER - 0.95 INCHES TEMP - 108.5 DEG F x x x x x END x 9 x x x n ARCO 5526 900 MONTEREY ST BAKERSFIELD.CA93305 805 - 861-1972 SEP 6. 2011 1:24 PM SYSTEM STATUS REPORT T 3:HICHPRODUCT ALARM L 3:FUEL ALARM L 6:FUEL ALARM L 9:FUEL ALARM INVENTORY REPORT T I:UNLEADED SYPHON VOLUME 9528 GALS ULLAGE m 2099 GALS 904 ULLAGE- 936 GALS TO VOLUME = 9208 GALS HEIGHT - 69.65 11NCHES WATER VOL - 0 GALS WATER - 0.00 INCHES TEMP - 1.07. 8 DEG F T 2:UNLEADED MAIN VOLUME = 10671 GALS ULLAGE = 956 GALS 909 ULLAGE- 0 GALS TO VOLUME - 10314 GALS HEIGHT - 78.83 INCHES WATER VOL - 0 GALS WATER = 0.00 INCHES TEMP - 107.7 DEG F T 3:PREMIUM VOLUME = 11280 GALS ULLAGE 347 GALS 909 ULLAGE- 0 GALS TC VOLUME - 10897 GALS HEIGHT - 85.24 INCHES WATER VOL - 15 GALS WATER - 0.95 INCHES TEMP - 108.5 DEG F XXXXw END XXXXx SE14BOR ALARM L 9:PREMIUM TURBINE SUMP STP SUMP FUEL ALARM SEP 6. 2011 1:25 PM SENSOR ALARM - - - -- ARCO 5526L8:PREMIUM FILL SUMP ARCO 5526 900 MONTEREY ST OTHER SENSORS 900 MONTEREY ST BAKERSFIELD.CA93305FUELALARMBAKERSFIEL.D.CA93305 805- 861 -1972 SEP 6, 2011 1:26 PM 805-861 -1972 SENSOR ALARM - - - -- L 5:MAIN UNL FILL OTHER SENSORS FUEL ALARM SEP 6. 2011 1:27 PM SENSOR ALARM - - - -- L 2:5YPHON FILL SUMP OTHER SENSORS FUEL ALARM SEP 6, 2011 1 :30 P1i ARCO 5526 900 MONTEREY ST BAKEk1417 IELD- CA93305 805 - 861-1972 SEP 6 - 201 1 1 :3'D P11 SYSTEM STATUS REPORT T 3:HIGH PRODUCT ALARM L 2:FUEL ALARM SENSOR. ALARM L I:ANNUU R SYPHON ANNULAR SPACE FUEL ALARM SEP 6, 2011 1:33 PM SEP 6. 2011 1:35 PM SYSTEM STATUS REPORT T 3:HIGH PRODUCT ALARM L 1:FUEL ALARM SEIC40P ALARM - - - -- L 4:ANNULAR MAIN UNL ANNULAR SPACE - FUEL ALARM SEP 6. 2011 1:39 PM SENSOR ALARM --- -- L 7': NREM 1 UPI ANNULAR ANNULAR SPACE FUEL ALARM SEP 6. 2011 '1:44 PM SENSOR ALARM --- -- L 7:PREMIUM ANNULAR ANNULAR SPACE FUEL ALARM SEP 6. 2011 1:44 PM SEP 6. 2011 1:45 P1l SYSTEM STATUS REPORT T 3:HIGH PRODUCT ALARM L 7:FUEL ALARM IN -TANK ALARM - -- -- T 2 : UNLEADED MAI N HIGH PRODUCT ALARM SEP 6, 2011 1 :49, PM IN-TANK ALARM -- - -- T 2:UNLEADED MAIN MAX PRODUCT ALARM SEP 6, 2011 1:49 PM ARCO 5526 900 MONTEREY ST 6AKERSFIELD.CA93305 805 - 861 -1972 SEP 6, 2011 1:50 PM SYSTEM STATUS REPORT T 2:HIGH PRODUCT ALARM T 2:MAX PRODW7 ALARM T 3:1-11(;H PRODUCT ALARM ARCO 5526 900 MONTEREI' ST BAKERSFIELD.CA93305 805 - 861 -1972 SEP 6. 2011 1:50 P11. SYSTEM - STATUS - REiPORT T 2:HICH PRODUCT ALARM T 2:MAX PRODUCT ALARM T 3:HIGH PRODUCT ALARM ARCO 5526 900 MONTEREY ST BAYERSFIELD.CA93305 805 - 861-1972 SEP 6. 2011 1:50 PM SYSTEM STATUS REPORT T 2:H1GHPRODUCT ALARM T 2:MAX PRODUCT ALARM T 3:HIGH PRODUCT ALARM SENSOR ALARM - - - -- L10:1-2 UDC DISPENSER PAN FUEL ALARM SEP 6, 2011 1 :53 PM T I:UNLEADED SYPHON INVENTORY INCREASE INCREASE sTAKrr SEP 6. 20111 1:4e PM VOLUME 9527 GALS HEIGHT - 69.64 INCHES WATER 000 INCHES TEMP 10i A DEC F INCREASE END SEP 6. 2011 1:55-Ph1 VOLUME' - 9706 GALS HEIGHT - 71.18 INCHES WATER - 0.00 LNCHES TEMP - 107.8 DEG F GROSS INCREASE- 209 TC NET INCREASE- 203 SENSOR ALARM --- -- 1.11:3-4 UDC DISPENSER PAN FUEL ALARM SEP 6. 2011 1:57 PM SENSOR ALARM - -- -- L13:7 -S UDC DISPENSER PAN FUEL ALARM SEP 6. 2011 1:59 PM SEP60R ALARM - - - -- L12:5-6 UDC DISPENSER PAN FUEL ALARM SEP 6. 2011 2:00 PM SEN50R ALARM L14:9-10 Urr<.' DISPENSER PAN FUEL ALAR11 SEP 6. 2011 2:01 PM SENSOR ALARM -- - -- L15:11-12 UK' DISPENSER PAN FUEL ALARM SEP 6. 2011 2:03 PM SENSOR ALARM L13:7 -8 UDC DISPENSER PAN SENSOR OUT ALARM SEP 6, 2011 2:05 PM SENSOR ALARM - - - -- L 9: PREM I UM TURB 114E SUMP STP SUMP SENSOR OUT ALARM SEP 6. 2011 2:05 PM SENSOR ALARM L14:9 -10 UDC DISPENSER PAN SENSOR OUT ALARM SEP 6. 2011 2 :05 PM SENSOR ALARM - - - -- L 1:ANNULAR SYPHON ANNULAR. SPACE SENSOR OUT ALARM SEP 6, 2011 2:05 PM SENSOR ALARM - - - -- 1-10:1-2 UDC DISPENSER PAN SENSOR OUT ALARM SEP 6, 2011 2:05 PM SEW-OR ALARM - -- -- 1-1,5:11 -12 UDC DISPENSER PAN ttENSOR OUT ALARM SEP 6, 2011 2:05 PM SENSOR ALARM -- L 2:SYPfWN FILL SUMP. OTHER SENSORS SENSOR OUT ALARM SEP 6. 2011 2:05 P11 SENSOR ALARM -- --- L 1' 1 : 3- 4 UDC DISPENSER PAP! SENSOR OUT ALARM SEP 6, 2011 . 2:05 PM SENSOR ALARM -- --- L 3:SYPHON TURDINE SUMP PIPING SUMP SENSOR OUT ALARM SEP 6, 2011 2:05 PM SENSOR ALARM - - - -- L12:5-6 Utt DISPENSER PAN SENSOR OUT ALARM SEP 6, 2011 2:05 PM SENSOR ALARM - - - -- L 5:MAIN UNL FILL OTHER SENSORS SENSOR OUT ALARM SEP 6, 2011 2:05 PM ARCO 5526 900 MONTEREY ST BAMERSFIELD,CA93305 805 - 861 -1972 SEP 6. 2011 2:05 PM SYSTEM STATUS REPORT T 3:HIGH PRODUCT ALARM L I:SENSOR OUT ALARM L 2:SENSOR OUT ALARM L 3 :SENSOR OUT ALARM L 4:SENSOR OUT ALARM L 5:SENSOR OUT ALARM L 6:SENSOR OUT ALARM L 9:SENSOR OUT ALARM LIO:SENSOR OUT ALARM LII:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L14:SENSOR OUT ALARM L 15 : SEPItSOR OUT ALARM 0 ARCO 5526 900 MONTEREY ST BAKERSFIELD- CA93305 805 -861 -1972 SEP 6, 2011 2:05 P1l SYSTEM STATUS REPORT T 3: H I GH PRODUCT AI..ARM L 1:SENSOR OUT ALARM L 2:SENSOR OUT ALARM L 3:SENSOR OUT ALARM L 4 : SEIVSOR OUT ALr -RM L 5:SENSOR OUT ALARM L 6:SENSOR OUT ALARM L 9:SENSOR OUT ALARM LIO:SENSOR OUT ALARM L I I : SENSOR OU1' ALARM L12:SENSOR OUT ALARM L13 : SENSOR OUT ALARM L14:SENSOR OUT ALARM L15. :SENSOR OUT ALARM SENSOR ALARM - - -- L 4tANNULAR MAIN UNL ANNULAR SPACE SENSOR OUT ALARM SEP 6, 2011 2:05 PM SENSOR ALARM - - - -- L-6: MA I N U14L 'TURBINE STS? SUMP SENSOR OUT ALARM SEP 6.. 2611, 2:05 PM SENSOR ALARM L ?:PREMIUM ANNULAR ANNULAR SPACE SENSOR OUT ALARM SEP 6, 2011 2:05 PM SENSOR ALARM -- - -- L B:PREMIUM FILL SUMP OTHER SENSORS SENSOR OUT ALARM SEP 6, 2011 2:06 PI-1 TENSOR ALARM - - - -- L13:74 UDC- DISPENSER PAN SENSOR OUT ALARM SEP 6. 2011 2:08 PM SENSOR ALARM - - - -- 14:9-10 UDC DISPENSER PAN SENSOR OUT ALARM SEP 6, 2011 2:09 PM SENSOR (ALARM - - - -- L !:ANNULAR SYPHON ANNULAR SPACE SENSOR OUT ALARM SEP 6. 2011 2:09 P11 SENSOR ALARM - - - -- L 9:PREMIUM TURBINE SUMP STP SUMP SENSOR OUT ALARM SEP 6. 2011 2:09 PM SENSOR ALAPI.1 - - - -- L15:11-12 UDC DISPENSER PAN SENSOR OUT ALARM SEP 6. 2011 2:09 PM SENSOR ALARM LID: 1-2 UDC DISPENSER PAN SENSOR OUT ALARM SEP 6. 2011 2:09 PM SENSOR ALARM - - - -- L 5:MAIN UNL FILL OTHER SENSORS SENSOR OUT ALARM SEP E. 20i1 2:09 PM SENSOR ALARM - - - -- L 6:MAIN UNL TURBINE STP SUMP SENSOR OUT ALARM SEP 6. 2011 2:09 PIH SENSOR ALARM - - - -- L B:PREMIUM'FILL SUMP OTHER ,SENSORS SENSOR OUT ALARM SEP 6, 2011 * 2:09 P11 i SENSOR ALARM - -- L 2:SYFHO0 FILL'SUMP OTHER. SENSORS - SENSOR OUT ALARM SEP, 6. 2011 2:09 PM I SENSOR ALARM - ---- L 3.:SYPHON TURBINE SUMP PIPING SUMP SENSOR OUT ALARM SEP 6, 2011 2:09 PI•I SENSOR ALARM - - - -- L 4:ANNULAR MAIN IJNL ANNULAR SPACE SENSOR"OUT ALARM SEP 6, 2011 2:09 PM SENSOR ALARM - - - -- LIC:3 -4 UDC D•1SPE14SER PAN SENSOR OUT ALARM SEPa 6. 2011 2:09 PM SENSOR ALARM - - - -- L12:5-6 UDC DISPENSER PAN SENSOR OUT ALARM SEP 6. 2011 2:09 PM SENSOR ALARM - - - -- L 7:PREMIUM ANNULAR ANNULAR SPACE SENSOR OUT ALARM SEP 6, 2011 2:09 PM ARCO 5526 900 MC- NTEREY ST BAI'MF I ELD - CA93305 805 -861 -1972 SEP 6. 2011 2:09 PM SYSTEM STATUS REPORT T 3:H1GH PRODUCT ALARM IN -TANK ALARM - - - -- - - -- IN -TANK ALARM - - - -- - - -- IN -TANK. ALARM -- -- T 2:UNLEADED MAIN T 3:PREMIUM T 2:UNLEAISED MAIN HIGH PRODUCT ALARM PROBE OUT PROBE OUT SEP 6. 2011 2:21 PM SEP 6. 2011 2:24 PM SEP 6. 2011 2:26 PM IN -TANK ALARM - - - -- - - -- IN -TANK ALARM - - - -- __ -- IN-TANX ALARM - - - -- f 2: UIVI.EADED MA I N T 3: PREM 1 Uhl T 2: UNLEADED MA IN MAX PRODUCT ALARM 1 LAVAL I D FUEL LEVEL LOW TEMP WAR141 Ni` SEP 6, 2011 2:21 PM SEP 6. 2011 2:25 PM SEP 6, 2011 2:27 Pl1 AKO 5526 IN -TANK ALARM - - - -- 1N-TANX: ALARM ----' 900 MONTEREY ST T 3:PREMIUM • T I:UNLEADED SYPHONBAKERSFI,ELD- CA93305 LOW PRODUCT ALARM MAX PRODUCT ALARM 805-861-11972 SEP 6. 2011 2:25 PM SEP 6, 2011 2:27 PM SEP 6. 2011 2:22 PIi SYSTEM S'PATUS REPORT T 2 :HIGH PRODU C -T ALARM T 2:MAX PRODUCT ALARM IN-TANK ALARM - - - -- IN -TANi, ALARM - - --- T 3:PREMIUM T I:UNLEADED SYPHONDELIVERYNEEDEDHIGHPRODUCTALARMSEP6. 2011 2 :25 PM SEP 6. 2011 2:27 PM IN -TANK ALARM - - - -- T 3:PREMIUM - - -- IN -TANK ALARM - - - -- - - -- 1N -TANK ALARM -- - -- HIGH PRODUCT ALARM T 2:UNLEADED MAIN T I:UNLEADED SYPHONSEP6. 2011 2:24 PM HIGH PRODO3'T ALARM OVERFILL ALARM SEP 6, 2011 2:25 PM SEP 6, 2011 2 :28 PM 1N -TANK ALARM - - - -- T 3:PREMIUM - - -- IN -TANI' ALARM - - IN -TANi: ALARM - ---- MAX PRODUA T ALARM T 2:UNLEADED MAIN T I:UNLEADED SYPHONSEP6, 2011 2:24 PM MAX PRODLk-,T ALARM PROBE OUTSEP6. 2011 2:25 PM SEP 6. 2011 2:28 Pit IN -TANK ALHRil - - - -- T 3:PREMIUM - - -- IN -TANY ALARM - - - -- - -- IN -TANK ALAP.M - - - -- OVERFILL ALARM T 2:UNLEADED MAIN T I:UNLEADED SYPHONSEP6. 2011 2:24 PH OVERFILL ALARM LOW TEMP WARNINGSEP6.. 2011 2:26 P14 SEP 6. 2011 2:29 PM T 3:PREMIUM INVENTORY INCREASE INCREASE START SEP 6. 2011 2:23 PM VOLUME - 8114 GALS HEIGHT - 60.09 INCHES WATER - 0.76 INCHES TEMP - 109.1 DEC F INCREASE END SEP 6. 2011 2:30 PM VOLUME - 11627 GALS HE1r,HT - 108.25 INCHES WATER - 1.07 INCHES TEMP - 108.5 DEG F GROSS INCREASE- 3513 TC NET INCREASE- 3396 T 2:UNLEADED MAIN I NVENTOR`,' I NCREASE INCREASE START SEP 6. 2011 2:25 PM VOLUME - 9576 GALS HEIGHT - 70.00 INCHES WATER - 1.02 INCHES TEMP - 106.8 DEG F INCREASE END SEP 6. 2011 2:32 PM VOLUME - 11627 GALS HEIGHT - 108.32 INCHES WATER - 1.25 INCHES TEMP - 108.4 DEG F GROSS INCREASE- 2051 TC NET INCREASE- 1983 ARCO 5526 900 MONTEREY ST SAKERSFIELD.CA933U5 805 -861 -1972 SEP 6. 2011 2:32 PM SYSTEM STHTUS REPORT T 3:LOW PRODIA:T ALARM T 3:DELIVERY NEEDED ARCO 5526 900 MONTEREY ST BAKERSFIELD.CA93305 805 - 861 -1972 SEP 6, 2011 2:32 PM SYSTEM STATUS REPORT T 3:LOW PRODUCT ALARM T 3:DELIvERY NEEDED ARM 5526 900 MONTEREY ST BAKERSFIELD.CA93305 805 - 861 -1972 SEP 6. 2011 2:.32 Phl SYSTEM STATUS REPORT T 3:LOW PRODUCT ALARM T 3:DELIVERY NEEDED ARCO 5526 900 MONTEREY ST BAXERSFIELD.CA93305 805-861 -1972 SEP 6, 2011 2:32 P11 SYSTEM STATUS REPORT r 3:LOW PRODUCT ALARM T 3:DELIVERY NEEDED a ARCO 5526 900 MONTEREY ST BAXERSFIELD.CA93305 805- 861 -1972 SEP 6. 201,1 2:32 PM SYSTEM STATUS REPORT T 3:LOW PRODUCT ALARM T 3:15ELIVERY WEEDED T I:UNLFADED SYPHON INVENTORY INCREASE INCREASE START SEP 6. 2011 2:27 PM VOLUME - 9737 GALS HEIGHT - 71.19 INCHES WATER - 0.00 INCHES TEMP - 109.2 DEG F I NCREA.SE END SEP 6. 2011 2:31 PM VOLUME - 11627 GALS HEIGHT - 111.66 1NCHES WATER - 0.00 INCHES TEMP - 109.1 DEG F GROSS INCREASE- 1090 TC NET INCREASE- 1827 SWRCB, January 2006 Spill Bucket Testing Report Form Thisform is intendedfor use by contractors performing annual testing of USTspill containment structures. The completedform and printoutsfrom tests (ifapplicable), should be provided to thefacility owner /operatorfor submittal to the local regulatory agency. 1. FACILITY INFORMATION Facility Name: Arco AM PM I Date of Testing: 9/6/2011 Facility Address: 900 Monterey Street, Bakersfield, CA 93305 Facility Contact: Alondra Hernandez I Phone: 661- 835 -8044 Date Local Agency Was Notified of Testing: 8/22/2011 Name of Local Agency Inspector (fpresent during testing): Ernie Medina 2. TESTING CONTRACTOR INFORMATION Company Name: Confidence UST Services, Inc. Technician Conducting Test: Bryan A Self Credentials: Z CSLB Contractor Z ICC Service Tech. Z SWRCB Tank Tester Other (Sped) License Number(s): CSLB# 804904 ICC# 8022804 SWRCB# 11 -1756 3. SPILL BUCKET TESTING INFORMATION Test Method Used: x Hydrostatic Vacuum Other Test Equipment Used: Lake Test Equipment Resolution: 0.0625" Identify Spill Bucket (By Tank Number, Stored Product, etc.) 1 Regular Master 2 Regular Slave 3 Super 4 Bucket Installation Type: Direct Bury x Contained in Sump Direct Bury x Contained in Sump Direct Bury x Contained in Sump Direct Bury Contained in Sum Bucket Diameter: 14.00" 14.00" 14.00" Bucket Depth: 12.00" 12.00" 12.00" Wait time between applying vacuum /water and start of test: 5 min. 5 min. 5 min. Test Start Time (Ti): 1:00pm 1:00pm 1:00pm Initial Reading (RQ: 9.75" 10.25" 9.75" Test End Time (TF): 2:00pm 2:00pm 2:00pm Final Reading (RF): 9.75" 10.25" 9.75" Test Duration (TF — Tj): 1 hour 1 hour 1 hour Change in Reading (RF - Ri): 0.00" f 0.00" 0.00" Pass/Fail Threshold or Criteria: 0.0625" 0.0625" 0.0625" Test Result: 9 Pass Fail x Pass Fall Z Pass Fail Pass Fail Comments — (include information on repairs made prior to testing, and recommendedfollow -upforfailed tests) CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING I hereby certify that all the information contained in this report is true, accurate, and in full compliance with legal requirements. Technician's Signature: Date: 9/6/2011 State laws and regulations do not cuVently require testing to be performed by a qualified contractor. However, local requirements may be more stringent. Key 1) VeederRooT TLS 350 2) ESO 3) Exterior Overfill Alarm 4) ATG Probe 5) VeederRoot 208 Sump Senser 6) VeederRoot 209 Annular Senser 7) VeederRoot Red Jackit LLD 8) F.E.Petro LLD 9) Fill SB 10) Vapor SB roll Arco AM /PM 900 Monterey ST Bakersfield CA, 93305 ILI 2 5 O 9 10 0 8 Super 2 5 09100 7 Re ular 2 5 O 90 10 40 7 Regular