HomeMy WebLinkAbout2011 FMC RESULTSare olo • y 11000 N. MoPac Expressway, Suite 500 Austin, Texas 78759 Phone: (512) 451 -6334 Fax: (512) 459 -1459 BAKERSFIELD FIRE DEPARTMENT OFFICE OF ENVIRONMENTAL SERVICES INSPECTOR CRAIG PERKINS 1501 TRUXTUN AVE. BAKERSFIELD, CA. 93301 Test Date: 06/29/2011 Order Number: 2282002 Dear Regulator, Date Printed and Mailed: 07/15/2011 Enclosed are the results of recent testing performed at the following facility: VALERO 3074 3225 BUCK OWENS BLVD. HWY 99 /HWY 58 BAKERSFIELD, CA. 93301 Testing performed: Impact Valve Leak detector tests Line tests Monitor Certification Sincerely, Dawn Kohlmeyer Manager, Field Reporting TANKNOLOGY CERTIFICATE OF TESTING di P %an Q:119y 8501 N. MOPAC EXPRESSWAY #400, AUSTIN, TEXAS 78759 TELEPHONE (512) 451 -6334 FAX (512) 459 -1459 PURPOSE: COMPLIANCE TEST RESULT SUMMARY REPORT WORK ORDER NUMBER: 2282002 TEST DATE: 06129/11 CLIENT: VALERO 685 W THIRD ST HANFORD, CA 93230 SANDY HUFF 559)583 -3298 CUSTOMER PO: SITE: VALERO 3074 3225 BUCK OWENS BLVD. HWY 99 /HWY 58 BAKERSFIELD, CA 93301 MANAGER -JOEL 661)324 -9481 Tank Tinhtnacs Taste Rpcultc TFRT TvPF• NONE TANK PRODUCT TANK TANK'' = TANK.. ;' PRODUCT EXTERNAL* TEST RESULT TEST RESULT•: ID A B C , D CAPACITY DIAMETER MATERIAL LEVEL. WATER LEVEL WET. ULLAGE ,`, 87 UNLEADED 14,130 95.00 DW STEEL PRESSURE P 0.000 TLD -1 91 PREMIUM 10,140 95.00 DW STEEL 0.000 TLD -1 Y 201t 6 2011 DIESEL 20,068 129.0 DW STEEL Y SATTELIT8 SATTELIT8 SATTELITES DIESEL 1 1.00 DW STEEL wncrc reguiauons require, [Or vacu r cct external water lever may De aepm of ury wcu or water is assumeu at iowest point mat can oc comirmeu ury. Prndur_t Pine Tiahtness Test Results LINE LINE; -- DELIVERY TEST: RESULT.' FINAL LEAK RATE,. (gph) TEST_ IMPACT ' =' VALVE" ID MATERIAL TYPE:; A B C , D A - B C D RESULT. MANUFACTURER. MODEL # w, SERIAL # 12ESULT 87 3 RED JACKET FX1V FUNCTION 87 3 DW FIBERG PRESSURE P 0.000 TLD -1 Y 91 4 DW FIBERG PRESSURE P 0.000 TLD -1 Y 201t 6 DW FIBERG PRESSURE P 0.000 TLD -1 Y SATTELIT8 SATTELIT8 y Fvictinn I ina I oak natartnr Tact U LINE, ID EXISTING'LEA DETECTOR' 1' = " EXISTING LEAK DETECTOR 2 --, MANUFACTURE MODEL #'. " SERIAL.# RESULT. MANUFACTURER. MODEL # w, SERIAL # 12ESULT 87 3 RED JACKET FX1V 205083195 P 91 4 RED JACKET FX1V 302089410 P 201t 6 RED JACKET FX1 -DV 302047281 P SATTELIT8 Now Ranlacamant I inc± I Pak I)etartnr Tact d LINE RE LACE TECTOR #1 REPL CEDIEAK DETECTOR MANUFACTURER MODEL,*., SERIAL # RESULT - MANUFACTURER' MODEL # SERIAL' - RE8ULTID For owner detailed report information, visit www.tanknology.coni and select Or -t.ine Kcports -W KnP, or contact your local 'fanknology oillec. Tester Name: JON ADAMS Technician Certification Number: Tester Signature: S Date Signed: /Z') I dcclarC under penaltyof perjury that I ant a licensed lank tester in the State ofCalifornia and that the information contained in this report is true and Correct to the best of my knowledge. INDIVIDUAL TANK INFORMATION AND TEST RESULTS Z111111 M3r*rK*W 8501 N MOPAC EXPRESSWAY, SUITE 400 TEST DATE: 06/29/11 AUSTIN, TEXAS 78759 (512) 451 -6334 WORK ORDER NUMBER: 2282002 CLIENT: VALERO SITE: VALERO 3074 TANK INFORMATION Tank ID: 87 3 Tank manifolded: NO Bottom to top fill in inches: 140.5 Product: UNLEADED Vent manifolded: YES Bottom to grade in inches: 146.0 Capacity in gallons: 14,130 Vapor recovery manifolded: YES Fill pipe length in inches: 44.5 Diameter in inches: 95.00 Overfill protection: YES Fill pipe diameter in inches: 4.0 Length in inches: 466 Overspill protection: YES Stage I vapor recovery: DUAL Material: Dw STEEL Installed: ATG Stage II vapor recovery: ASSIST CP installed on: COMMENTS TANK TEST RESULTS Test Method: NONE LEAK DETECTOR TEST RESULTS Test method: PSI at tank bottom: New /passed Failed /replaced New /passed Failed /replaced Fluid level in inches: L.D. #1 L.D. #1 L.D. #2 L.D. #2 LIFT/OFT: Make: RED JACKET Fluid volume in gallons: Model: Fx1V Tank water level in inches: S /N: 205083195 Test time: NOT Open time in sec: 3.00 Number of thermisters: TESTED Holding psi: 12 NOT Specific gravity: Resiliency cc: 75 TESTED Water table depth in inches: rest leak rate ml /m: 189.0 Determined by (method): Metering psi: 10 Leak rate in gph: Calib. leak in gph: 3.00 Result: Results: PASS COMMENTS COMMENTS ULLAGE TEST RESULTSTest Method: NONE LINE TEST RESULTS Test type: TLD -1 Test time: Ullage volume: Material: Dw FIBERG Ullage pressure: Diameter (in): 2.0 Results: Length (ft): 100.0 Test psi: 50 DATA FOR UTS-4T ONLY: Bleedback cc: 11 Time of test 1: Test time (min): 30 Temperature: NOT Start time: 13:30 NOT NOT NOT Flow rate (cfh): TESTED End time: 14:00 TESTED TESTED TESTED Time of test 2: Final gph: 0.000 Temperature: Result: PASS Flow rate (cfh): Pump type: PRESSURE Time of test 3: Pump make: RED JACKET Temperature: Flow rate (cfh): Impact Valves Operational: YES COMMENTS COMMENTS Printed 07/15/2011 09:09 MTUTTLE INDIVIDUAL TANK INFORMATION AND TEST RESULTS p, Tanknobgy 8501 N MOPAC EXPRESSWAY, SUITE 400 TEST DATE: 06/29/11 AUSTIN, TEXAS 78759 (512) 451 -6334 WORK ORDER NUMBER: 2282002 CLIENT: VALERO SITE: VALERO 3074 TANK INFORMATION Tank ID: 91 4 Tank manifolded: NO Bottom to top fill in inches: 138.5 Product: PREMIUM Vent manifolded: YES Bottom to grade in inches: 145.0 Capacity in gallons: 10,140 Vapor recovery manifolded: YES Fill pipe length in inches: 42.5 Diameter in inches: 95.00 Overfill protection: YES Fill pipe diameter in inches: 4.0 Length in inches: 334 Overspill protection: YES Stage I vapor recovery: DUAL Material: Dw STEEL Installed: ATG Stage II vapor recovery: ASSIST CP installed on: COMMENTS TANK TEST RESULTS Test Method: NONE LEAK DETECTOR TEST RESULTS Test method: PSI at tank bottom: New /passed Failed /replaced New /passed Failed /replaced Fluid level in inches: L.D. #1 L.D. #1 L.D. #2 L.D. #2 LIFT/OFT: Make: RED JACKET Fluid volume in gallons: Model: Fx1V Tank water level in inches: S /N: 302089410 Test time: NOT Open time in sec: 5.00 Number of thermisters: TESTED Holding psi: 14 NOT Specific gravity: Resiliency cc: 100 TESTED Water table depth in inches: Test leak rate ml /m: 189.0 Determined by (method): Metering psi: 6 Leak rate in gph: Calib. leak in gph: 3.00 Result: Results: PASS COMMENTS COMMENTS ULLAGE TEST RESULTSTest Method: NONE LINE TEST RESULTS Test type: TLD -1 Test time: Ullage volume: Material: Dw FIBERG Ullage pressure: Diameter (in): 2.0 Results: Length (ft): 100.0 Test psi: 50 DATA FOR UTS-4T ONLY: Bleedback cc: 8 Time of test 1: Test time (min): 30 Temperature: NOT Start time: 13:30 NOT NOT NOT Flow rate (cfh): TESTED End time: 14: 00 TESTED TESTED TESTED Time of test 2: Final gph: 0.000 Temperature: Result: PASS Flow rate (cfh): Pump type: PRESSURE Time of test 3: Pump make: RED JACKET Temperature: Flow rate (cfh): Impact Valves Operational: YES COMMENTS COMMENTS Printed 07/15/2011 09:09 MTUTTLE INDIVIDUAL TANK INFORMATION AND TEST RESULTS Jr Tanknology 8501 N MOPAC EXPRESSWAY, SUITE 400 TEST DATE: 06/29/11 AUSTIN, TEXAS 78759 (512) 451 -6334 WORK ORDER NUMBER: 2282002 CLIENT: VALERO SITE: VALERO 3074 TANK INFORMATION Tank ID: 20k 6 Tank manifolded: NO Bottom to top fill in inches: 193.0 Product: DIESEL Vent manifolded: NO Bottom to grade in inches: 201.0 Capacity in gallons: 20,068 Vapor recovery manifolded: NO Fill pipe length in inches: 64.0 Diameter in inches: 129.00 Overfill protection: YES Fill pipe diameter in inches: 4.0 Length in inches: 358 Overspill protection: YES Stage I vapor recovery: NONE Material: DW STEEL Installed: ATG Stage II vapor recovery: NONE CP installed on: COMMENTS Lines b, c, d and a & b form tank #bare all stilite lines. TANK TEST RESULTS Test Method: NONE LEAK DETECTOR TEST RESULTS Test method: PSI at tank bottom: New /passed Failed /replaced New /passed Failed /replaced Fluid level in inches: L.D. #1 L.D. #1 L.D. #2 L.D. #2 LIFT /OFT: Make: RED JACKET Fluid volume in gallons: Model: Fx1 -DV Tank water level in inches: S /N: 302047291 Test time: NOT Open time in sec: 3.00 Number of thermisters: TESTED Holding psi: 150 NOT Specific gravity: Resiliency cc: 155 TESTED Water table depth in inches: Test leak rate ml /m: 189.0 Determined by (method): Metering psi: 12 Leak rate in gph: Calib. leak in gph: 3.00 Result: Results: PASS COMMENTS COMMENTS ULLAGE TEST RESULTSTest Method: NONE LINE TEST RESULTS Test type: TLD -1 Test time: Ullage volume: Material: DW FIBERG DW FIBERG DW FIBERG DW FIBERG Ullage pressure: Diameter (in): 3.0 2.0 2.0 2.0 Results: Length (ft): 220.0 20.0 20.0 20.0 Test psi: 50 DATA FOR UTS-4T ONLY: Bleedback cc: 80 Time of test 1: Test time (min): 30 Temperature: NOT Start time: 10:15 NOT NOT NOT Flow rate (cfh): TESTED End time: 10:45 TESTED TESTED TESTED Time of test 2: Final gph: 0.000 Temperature: Result: PASS Flow rate (cfh): Pump type: PRESSURE NONE NONE NONE Time of test 3: Pump make: RED JACKET NONE NONE NONE Temperature: Flow rate (cfh): Impact Valves Operational: YES COMMENTS COMMENTS Printed 07/15/2011 09:09 MTUTTLE MONITORING SYSTEM CERTIFICATION For Use By All Jurisdictions Within the State of California Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3 Title 23, California Code of Regulations This form must bb used to document testing and servicing of monitoring equipment. If more than one monitoring system control panel is installed at the facility, a separate certification'or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner /operator. The owner /operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. A. General Information Facility Name: VALERO 3074 Site Address: 3225 BUCK OWENS BLVD. HWY 99 /HWY 58 Facility Contact Person: MANAGER -JOEL Make /Model of Monitoring System:TLS -350 B. Inventory of Equipment Tested /Certified Check the appropriate boxes to indicate specific equipment inspected /serviced City: BAKERSFIELD Contact Phone No: 324 -9481 Date of Testing /Service: 06/29/2011 Work Order Number: 2282002 CA Zip: 93301 Tank ID: T -1 Tank ID: T -2 PREMIUM X In -Tank Gauging Probe. Model: MAG X In -Tank Gauging Probe. Model: MAG X Annular Space or Vault Sensor. Model: 420 Annular Space orVault Sensor. Model: 420 X Piping Sump/Trench Sensor(s). Model: 208 Piping Sump/Trench Sensor(s). Model: 208 X Fill Sump Sensor(s). Model: 208 Fill Sump Sensor(s). Model: 208 X Mechanical Line Leak Detector. Model: FX1V X Mechanical Line Leak Detector. Model: FX1V Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: X Tank Overfill /High -Level Sensor. Model: E/A Tank Overfill /High -Level Sensor. Model: E/A Other (specify equipment type and model in Section E on page 2). Other (specify equipment type and model in Section E on page 2). Tank ID: Tank ID: In -Tank Gauging Probe. Model: MAG In -Tank Gauging Probe. Model: 71 Annular Space or Vault Sensor. Model: 420 Annular Space orVault Sensor. Model: X Piping Sump/Trench Sensor(s). Model: 208 Piping Sump/Trench Sensor(s). Model: X Fill Sump Sensor(s). Model: 208 Fill Sump Sensor(s). Model: X Mechanical Line Leak Detector. Model: FX1 DV Mechanical Line Leak Detector. Model: Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: Tank Overfill/High -Level Sensor. Model: E/A Tank Overfill /High -Level Sensor. Model: Other (specify equipment type and model in Section E on page 2). Otherequipment (specify eq p type and model in Section E on page 2). Dispenser : 1/2 Dispenser ID: 3/4 7 Dispenser Containment Sensor(s) Model: 7 Dispenser Containment Sensor(s) Model: XO Shear Valve(s). X-1 Shear Valve(s) Dispenser Containment Float(s) and Chain(s). X-1 Dispenser Containment Float(s) and Chain(s). Dispenser ID: 5/6 Dispenser ID: 7/8 Dispenser Containment Sensor(s) Model: Dispenser Containment Sensor(s). Model: RI Shear Valve(s). Shear Valve(s). X Dispenser Containment Float(s) and Chain(s). Dispenser Containment Float(s) and Chain(s). Dispenser ID: Dispenser ID: nDispenser Containment Sensor(s) Model: Dispenser Containment Sensor(s). Model: Shear Valve(s). Shear Valve(s). Dispenser Containment Float(s) and Chain(s). Dispenser Containment Float(s) and Chain(s). If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. C. Certification I certify that the equipment identified in this document was inspected /sery iced in accordance with the manufacturers' guidelines. Attached to this certification is information (e.g manufacturers' checklists) necessary to verify that this information is correct. and a Site Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a copy of the (Check all that apply): PflSystem set -up X Alarm history report Technician Name (print): JON ADAMS Signature: U-Li Certification No.: B37367 License. No.: 743160 (Class'A' General Enginering Contractor License) Testing Company Name:Tanknology Phone No.: (800) 8004633 Site Address: 11000 N. MoPac Expressway, suite 500, Austin, TX 78759 Date of Testing /Servicing: 06/29/2011 Monitoring System Certification Page 1 of 3 Based on CA form dated 03/08 Monitoring System Certification Site ,Address , 3225 BUCK OWENS BLVD. Date of Testing /Service: 06/29/2011 HWY 99 /HWY 58 D. Results of Testing /Servicing Software Version Installed: Complete the following checklist: X Yes 11 No' Is the audible alarm operational? Q Yes No • Is the visual alarm operational? Q Yes EJNo Were all sensors visually inspected, functionally tested, and confirmed operational? Q Yes E] No ' Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere with their proper operation? Yes No • x N/A If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) operational? Q Yes No • N/A For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate positive shut -down? (check all that apply) X SumpfTrench Sensors; Dispenser Containment Sensors. Did you confirm positive shut -down due to leaks aad sensor failure /disconnection? X Yes No XD Yes No' N/A For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e.: no mechanicaloverfillpreventionvalveisinstalled), is the overfill warning alarm visible and audible at the tank fill points(s) and operating properly? If so, at what percent of tank capacity does the alarm trigger? Yes* Fx No Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced and list the manufacturer name and model for all replacement parts in Section E, below. Yes* X No Was liquid found inside any secondary containment systems designed as dry systems? (check all that apply) Product; Water. If yes, describe causes in Section E, below. EX Yes No • Was monitoring system set -up reviewed to ensure proper settings? Attach set -up reports, if applicable. x Yes No • Is all monitoring equipment operational per manufacturers' specifications? In Section E below, describe how and when these deficiences were or will be corrected. E. Comments: Page 2 of 3 Based on CA form dated 03/08 Monitoring System Certification Site Address: 3225 BUCK OWENS BLVD. HWY 99 /HWY 58 F. In -Tank Gauging / SIR Equipment Check this box if no tank gauging or SIR equipment is installed. Date of Testing /Service: 06 /29/2011 Check this box if tank gauging is used only for inventory control. Check this box if no tank gauging or SIR equipment is installed. This section must be completed if in -tank gauging equipment is used to perform leak detection monitoring. Complete the following checklist: Yes ONO - Has all input wiring been inspected for proper entry and termination, including testing for ground faults? Yes No Were all tank gauging probes visually inspected for damage and residue buildup? Yes No Was accuracy of system product level readings tested? EEYes No' Was accuracy of system water level readings tested? X Yes No • Were all probes reinstalled properly? x Yes No Were all items on the equipment manufacturers' maintenance checklist completed? In the Section H, below, describe how and when these deficiencies were or will be corrected. G. Line Leak Detectors (LLD) : Check this box if LLDs are not installed. Complete the following checklist: O Yes No'E] N/A For equipment start-up or annual equipment certification, was a leak simulated to verify LLD performance? Check all that apply) Simulated leak rate: x 3 g.p.h 0.1 g.p.h 0.2 g.p.h x Yes No' Were all LLDs confirmed operational and accurate within regulatory requirements? FX-1 Yes No • Was the testing apparatus properly calibrated? Yes No' N/A For mechanical LLDs, does the LLD restrict product flow if it detects a leak? Yes No " x N/A For electronic LLDs, does the turbine automatically shut off if the LLD detects a leak? Yes No • 0 N/A For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? Yes El No x N/A For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a test? Yes No " x N/A For electronic LLDs, have all accessible wiring connections been visually inspected? 2 Yes No • Were all items on the equipment manufacturers' maintenance checklist completed? In the Section H, below, describe how and when these deficiencies were or will be corrected. H. Comments: Page 3 of 3 Based on CA form dated 03/08 Work Order: 2282002 NSO) & Perm - Vurs`.on I- 2W2A(i7 AOA Emergency Shut Off (ESO) & Dispenser Emergency Shutoff valve (ESV) ANNUAL TEST RECORD LOCATIONS AND TEST DATA Testing C:ontCon pan)': . -. - --- - - - - -- Hate- ..., _._.. Location Name. Store H: " State Ii) #: 4t dresS: 7.Z JUGIG C &-, VS ,y>d City: State: , Emergency Shut_Off (ESO) Testing, Results Un? _ m accordance with "ESO Vendor Letter (3- 21- 05).doe ", from Valero's Retail Compliance Department, as a part of annual compliance testing, (his representative tested the F.mct- geucyShut Off (ESO) switches indicated on this sketch. Findin s fisted below: l:mcrgcauy Shut Off (LSO) If No, Provide i Operational? M:Lintenance Log 4 Date Called: eraser Emergenev Shutoff Valve (EW)Jesting Results Ott ll in accordance with NFPA 30A this representative tested the automatic- closing feature of 0-ic Ili,.nenser Emergency Shutoff VALVE(S) (ESV) located in the supply linc5 at )6c base of cash individual island type dispenser indicated on the diagram below. Each dovice (4) / in ail, would: aut0ma(ical1V close. Findings listed below-, I)isa. F.mereencv Shut (lfl ' IfNo, Providc Valve (LSV) Operational? ( I - Maintenance I.og # Date Called : id :occmcni or Devicca Ttnk,:d 1 Si nature Of Representative: Tanknology Inc. 11000N. MoPac Expressway, Suite 500, Austin, Texas 78759 Work Order: 2282002 RJ LD TW RO;*rt(2-05a) (4),UDC RJ - LEAK DETECTOR TEST REPORT GaaWietioa vF ttus report fa regWred ftw aff mecharmaa/ leak dotector testing Valero Location Testin Com an Store #: Name Date of Test- I cr(y 1 State: I I CV/ Test Equipment Used MakelModel Type of Leak Detectors tested XLD XLP BFLD FX1D FX2 FX21D FX1 V FX2V OTHE=R l% Technigiian Name (print): Tachnician ificatiDn #: S Test Method Used AVO FTA FXT RJ 21) (RJ 20) (RJ 051 - 272 -1) DLD PLD 8FLD FX1 FX1 BFLD FX2BFLD J r FX1 DV FX2DV TEST INFORMATION Technician Signature: Date: Tanknology Inc. 1 1000 N. MoPac Expressway, Suite 500, Austin, Texas 78759 UL Leak Serial Resiliency Func. Opening Test Meterin Pass UL¢ Detector Number ml) Element Time Leak g PSI Or SU Type check sec) Rate Fail DIE see valve) mllmin above) Holding or PSI al/hr. IV3 is I b 912A2'0VA qio to 5 3 3 t, 4 5 6 7 8 Technician Signature: Date: Tanknology Inc. 1 1000 N. MoPac Expressway, Suite 500, Austin, Texas 78759 g3n 8501 N MOPAC EXPRESSWAY, SUITE 400 AUSTIN, TEXAS 78759 512) 451 -6334 FAX (512) 459 -1459 TEST DATE:06 /29/11 WORK ORDER NUMBER2282002 CLIENT:VALERO SITE:VALERO 3074 COMMENTS PARTS REPLACED QUANTITY DESCRIPTION 8 1 10 MICRON HIGH CAPACITY FILTER ETHANOL 3/4" MX 3/4" F SWIVEL HELIUM PINPOINT TEST RE5ULT5 (IF APPLICABLE) ITEMS TESTED HELIUM PINPOINT LEAK TEST RESULTS Printed 07/15/2011 09:09 MTUTTLE SITE DIAGRAM p, Tar*nology 8501 N MOPAC EXPRESSWAY, SUITE 400 AUSTIN, TEXAS 78759 512) 451 -6334 FAX (512) 459 -1459 TEST DATE: 06/29/11 WORK ORDER NUMBER2282002 CLIENT:VALERO SITE: VALERO 3074 9 s u m p 0-1 9 10 11 12 13 J ILL 9 1 1 2 S 0 S S 3 A S A A S T T T T A 5 T S P C -STORE MONITOR o U S O VALERO 3074 3225 Buck Owens Blvd 0 Bakersfield, CA CAR WASH I DSL co Co W TIN Co 4—/ c A 0p O VENTS REG :3 3 L- STP F V I a14K TP # 4 L S10" F V I PREM Printed 07/15/2011 09:09 MTUTTLE ATG Information 110100 JUN 29, 2011 3:00 PM VALERO 3074 3225 BUCK OWENS BAKERSFIELD,CA 93308 661- 324 -9481 SYSTEM STATUS REPORT ALL FUNCTIONS NORMAL 3 3 120100 JUN 29, 2011 3:00 PM VALERO 3074 3225 BUCK OWENS BAKERSFIELD,CA 93308 661- 324 -9481 IN -TANK INVENTORY TANK PRODUCT VOLUME TC VOLUME ULLAGE HEIGHT WATER TEMP 1 UNLEADED 7563 7403 6567 50.40 0.00 90.17 2 PREMIUM 2641 2596 7499 29.32 0.00 84.36 4 DIESEL 10172 10003 9896 64.44 0.00 96.87 3 130100 JUN 29, 2011 3:00 PM VALERO 3074 3225 BUCK OWENS BAKERSFIELD,CA 93308 661- 324 -9481 LIQUID STATUS REPORT SENSOR LOCATION STATUS 1 PREMIUM STP SUMP SENSOR NORMAL 2 UNLEADED STP SUMP SENSOR NORMAL 3 UNLEADED INT SENSOR NORMAL 4 PREMIUM INT SENSOR NORMAL 5 DIESEL STP SUMP SENSOR NORMAL 6 DIESEL INT SENSOR NORMAL 7 FILTER SUMP SENSOR NORMAL 8 UNLEADED FVR SUMP SENSOR NORMAL 9 PREMIUM FVR SUMP SENSOR NORMAL 10 DIESEL FVR SUMP SENSOR NORMAL 3 3 150301 JUN 29, 2011 300 PM 1:VALERO 3074 3 3 150302 JUN 29, 2011 3:00 PM 2:3225 BUCK OWENS 3 3 150303 JUN 29, 2011 300 PM 3:BAKERSFIELD,CA 93308 3 3 150304 JUN 29, 2011 3:00 PM 4:661- 324 -9481 3 3 151700 JUN 29, 2011 3:00 PM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM 3 3 150F00 2282002 Work Order# 2282002 ATG Information JUN 29, 2011 300 PM MON DD YYYY HH:MM:SS xM 3 3 110200 JUN 29, 2011 3:00 PM VALERO 3074 3225 BUCK OWENS BAKERSFIELD,CA 93308 661- 324.9481 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 4 PROBE / G.T. 159366 159416 2 INTERSTITIAL BD 199128 199168 3 INTERSTITIAL BD 200111 200097 4 UNUSED 9357814 8716645 5 UNUSED 9359316 8715658 6 UNUSED 9359034 8718022 7 UNUSED 9362068 8715364 8 UNUSED 9362155 8721385 9 RELAY BOARD 14972 14955 10 RELAY BOARD 15018 15017 11 UNUSED 9362143 8718471 12 UNUSED 9362716 8715772 13 UNUSED 9359139 8717829 14 UNUSED 9363293 8717082 15 UNUSED 9357616 8715731 16 UNUSED 9362127 8715316 COMM 1 SERIAL SAT BD 475630 475826 COMM 2 RS232 SERIAL BD 9362434 15059 COMM 3 PRINTER BOARD 9987 9990 3 3 160100 JUN 29, 2011 3:00 PM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 UNLEADED ON 2 PREMIUM ON 3 DIESEL OFF 4 DIESEL ON 3 160200 JUN 29, 2011 3:00 PM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 UNLEADED 2 PREMIUM 3 DIESEL 4 DIESEL 3 3 160300 JUN 29, 2011 300 PM TANK PRODUCT CODE TANK PRODUCT LABEL 1 UNLEADED 1 2 PREMIUM 3 3 DIESEL 4 4 DIESEL 4 3 3 160400 JUN 29, 2011 300 PM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 14130 2 PREMIUM 10140 3 DIESEL 20068 4 DIESEL 20068 3 3 160700 JUN 29, 2011 3:00 PM 2282002 Work Order# 2282002 ATG Information Work Order# 2282002 TANK DIAMETER TANK PRODUCT LABEL INCHES 1 UNLEADED 95.50 2 PREMIUM 95.50 3 DIESEL 127.50 4 DIESEL 127.50 3 160900 JUN 29, 2011 3:D0 PM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 UNLEADED 0.000700 2 PREMIUM 0.000700 3 DIESEL 0.000450 4 DIESEL 0.000450 3 3 161200 JUN 29, 2011 3:00 PM TANK MANIFOLDED PARTNERS. TANK PRODUCT LABEL MANIFOLDED TANKS 1 UNLEADED NONE 2 PREMIUM NONE 3 DIESEL NONE 4 DIESEL NONE 3 3 162100 JUN 29, 2011 3:00 PM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 0 2 PREMIUM 0 3 DIESEL 2000 4 DIESEL 0 3 3 162200 JUN 29, 2011 3:01 PM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 14130 2 PREMIUM 10140 3 DIESEL 20068 4 DIESEL 20068 3 3 162300 JUN 29, 2011 3:01 PM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 12717 2 PREMIUM 9126 3 DIESEL 18061 4 DIESEL 18061 3 3 162400 JUN 29, 2011 3:01 PM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 UNLEADED 1.5 2 PREMIUM 1.5 4 DIESEL 2.0 3 3 162800 JUN 29, 2011 3:01 PM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 14130 2 PREMIUM 10140 3 DIESEL 20068 2282002 ATG Information Work Order# 2282002 4 DIESEL 20068 3 3 162900 JUN 29, 2011 3:01 PM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 141 2 PREMIUM 101 3 DIESEL 200 4 DIESEL 200 3 3 170300 JUN 29, 2011 3:01 PM LIQUID TYPE SENSOR LOCATION TYPE 1 PREMIUM STP SUMP TRI -STATE (SINGLE FLOAT) 2 UNLEADED STP SUMP TRI -STATE (SINGLE FLOAT) 3 UNLEADED INT TRI -STATE (SINGLE FLOAT) 4 PREMIUM INT TRI -STATE (SINGLE FLOAT) 5 DIESEL STP SUMP TRI -STATE (SINGLE FLOAT) 6 DIESEL INT TRI -STATE (SINGLE FLOAT) 7 FILTER SUMP TRI -STATE (SINGLE FLOAT) 8 UNLEADED FVR SUMP TRI -STATE (SINGLE FLOAT) 9 PREMIUM FVR SUMP TRI -STATE (SINGLE FLOAT) 10 DIESEL FVR SUMP TRI -STATE (SINGLE FLOAT) 11 TRI -STATE (SINGLE FLOAT) 12 TRI -STATE (SINGLE FLOAT) 13 TRI -STATE (SINGLE FLOAT) 14 TRI -STATE (SINGLE FLOAT) 15 TRI -STATE (SINGLE FLOAT) 16 TRI- STATE (SINGLE FLOAT) 3 3 190200 JUN 29, 2011 3:01 PM SOFTWARE REVISION LEVEL VERSION 20.04 SOFTWARE# 346020 -100 -E CREATED - 02.12.27.05.00 NO SOFTWARE MODULE SYSTEM FEATURES: PERIODIC IN -TANK TESTS ANNUAL IN -TANK TESTS 3 3 IA0100 JUN 29, 2011 3:01 PM TYPE CODE LENGTH SERIAL NO. D /CODE TANK 1 UNLEADED MAG C001 96.00 070035 4144 TANK 2 PREMIUM MAG 0001 96.00 070037 4144 TANK 4 DIESEL MAG D004 132.00 516815 1804 3 3 IA0200 JUN 29, 2011 3:01 PM TANK 1 UNLEADED MAG GRADIENT = 348.8600 TANK 2 PREMIUM MAG GRADIENT= 348.3600 TANK 4 DIESEL MAG GRADIENT= 394.9500 3 3 120600 JUN 29, 2011 3:01 PM VALERO 3074 3225 BUCK OWENS BAKERSFIELD,CA 93308 661- 324 -9481 TANK ALARM HISTORY TANK1 UNLEADED SETUP DATA WARNING DEC 14, 2006 1:58 PM HIGH WATER ALARM JUN 29, 2011 12:52 PM JUL 1, 2010 9:35 AM JUN 23, 2009 8:54 AM 2282002 ATG Information OVERFILL ALARM JUN 29, 2011 12:56 PM JUN 29, 2011 12:44 PM AUG 8, 2010 12:30 PM LOW PRODUCT ALARM JUN 26, 2007 12:01 PM INVALID FUEL LEVEL JUN 29, 2011 12:46 PM JUL 1, 2010 9:21 AM JUN 12, 2008 9:27 AM PROBE OUT JUN 29, 2011 12:56 PM JUN 29, 2011 12:42 PM JUL 1, 2010 9:51 AM HIGH WATER WARNING JUN 29, 2011 12:52 PM JUL 1, 2010 9:35AM JUN 23, 2009 8:54 AM MAX PRODUCT ALARM JUN 29, 2011 12:45 PM JUL 1, 2010 9:43 AM JUN 23, 2009 9:00 AM LOW TEMP WARNING JUN 29, 2011 12:57 PM TANK 2 PREMIUM SETUP DATA WARNING DEC 14, 2006 1:58 PM HIGH WATER ALARM JUN 29, 2011 1:00 PM JUL 1, 2010 9:28 AM JUN 23, 2009 9:07 AM OVERFILL ALARM JUN 29, 2011 12:52 PM JUL 1, 2010 9:46 AM JUL 1, 2010 9:38 AM LOW PRODUCT ALARM JUN 26, 2007 12:01 PM APR 27, 2007 3:18 PM MAR 17, 2007 9:22 AM INVALID FUEL LEVEL JUL 1, 2010 9:51 AM JUL 1, 2010 9:20 AM MAR 30, 2009 10:53 AM PROBE OUT JUN 29, 2011 1:03 PM JUN 29, 2011 12:53 PM JUN 29, 2011 12:41 PM HIGH WATER WARNING JUN 29, 2011 1:00 PM JUL 1, 2010 9:28 AM JUN 23, 2009 9:07 AM MAX PRODUCT ALARM JUN 29, 2011 12:53 PM JUN 23, 2009 9:00 AM JUN 12, 2008 9:24 AM TANK 4 DIESEL HIGH WATER ALARM JUL 1, 2010 12:37 PM JUN 23, 2009 12:07 PM JUN 12, 2008 12:32 PM OVERFILL ALARM JUN 29, 2011 9:07 AM MAR 22, 2011 3:00 AM NOV 24, 2010 7:31 PM LOW PRODUCT ALARM JUN 26, 2007 11:04 AM MAR 26, 2007 6:38 PM INVALID FUEL LEVEL APR 24, 2010 7:52 PM APR 24, 2010 6:55 PM APR 24, 2010 6:39 PM PROBE OUT JUN 29, 2011 10:17 AM JUN 29, 2011 9:05 AM JUL 1, 2010 12:55 PM HIGH WATER WARNING JUL 1, 2010 11:48 AM APR 24, 2010 6:44 PM APR 24, 2010 6:38 PM DELIVERY NEEDED APR 24, 2010 7:52 PM APR 24, 2010 6:56 PM APR 24, 2010 6:39 PM MAX PRODUCT ALARM JUN 29, 2011 9:09AM JUL 1, 2010 11:41 AM APR 26, 2010 11:42 AM LOW TEMP WARNING APR 24, 2010 6:56 PM APR 24, 2010 1:49 PM APR 24, 2010 9:29 AM 3 3 IB01DO JUN 29, 2011 3:01 PM LIQUID DIAGNOSTIC REPORT SAMPLE HIGH LOW SENSOR COUNTER REF REF VALUE 1 5 5070 757 96604 2282002 Work Order# 2282002 ATG Information 2 5 5071 757 99983 3 5 5074 756 100442 4 5 5070 757 101143 5 5 5070 758 100285 6 5 5070 758 99782 7 5 5069 757 100329 8 5 5074 757 100760 9 5 5071 761 100814 10 5 5073 762 100303 11 5 5077 761 999999680 12 5 5074 761 999999680 13 5 5079 759 999999680 14 5 5080 760 999999680 15 5 5080 760 999999680 16 5 5078 760 999999680 3 3 130200 JUN 29, 2011 3:01 PM VALERO 3074 3225 BUCK OWENS BAKERSFIELD,CA 93308 661- 324 -9481 LIQUIDALARM HISTORY REPORT SENSOR LOCATION 1 PREMIUM STP SUMP JUN 29, 2011 12:37 PM SENSOR OUT ALARM JUN 29, 2011 12:29 PM FUEL ALARM JUL 1, 2010 12:11 PM SENSOR OUT ALARM 2 UNLEADED STP SUMP JUN 29, 2011 12:37 PM SENSOR OUT ALARM JUN 29, 2011 12:30 PM FUEL ALARM JUL 1, 2010 12:11 PM SENSOR OUT ALARM 3 UNLEADED INT JUN 29, 2011 12:37 PM SENSOR OUT ALARM JUN 29, 2011 12:25 PM FUEL ALARM JUL 1, 2010 12:11 PM SENSOR OUT ALARM 4 PREMIUM INT JUN 29, 2011 12:38 PM SENSOR OUT ALARM JUN 29, 2011 12:24 PM FUEL ALARM JUL 1, 2010 12:11 PM SENSOR OUTALARM 5 DIESEL STP SUMP JUN 29, 2011 12:37 PM SENSOR OUT ALARM JUN 29, 2011 8:58 AM FUEL ALARM JUL 1, 2010 12:11 PM SENSOR OUT ALARM 6 DIESEL INT JUN 29, 2011 12:37 PM SENSOR OUT ALARM JUN 29, 2011 8:59 AM FUEL ALARM JUN 8, 2011 1:06 PM FUEL ALARM 7 FILTER SUMP JUN 29, 2011 12:37 PM SENSOR OUT ALARM JUN 29, 2011 9:03 AM FUEL ALARM JUL 1, 2010 12:11 PM SENSOR OUT ALARM 8 UNLEADED FVR SUMP JUN 29, 2011 12:37 PM SENSOR OUT ALARM JUN 29, 2011 12:26 PM FUEL ALARM DEC 20, 2010 11:34 PM FUELALARM 9 PREMIUM FVR SUMP JUN 29, 2011 12:37 PM SENSOR OUT ALARM JUL 1, 2010 12:11 PM SENSOR OUT ALARM JUL 1, 2010 9:14 AM FUEL ALARM 10 DIESEL FVR SUMP JUN 29, 2011 12:37 PM SENSOR OUT ALARM JUN 29, 2011 8:57 AM FUEL ALARM APR 7, 2011 11:51 PM FUEL ALARM 3 3 120700 JUN 29, 2011 3:01 PM VALERO 3074 3225 BUCK OWENS BAKERSFIELD,CA 93308 661- 324 -9481 TANK LEAK TEST HISTORY 2282002 Work Order# 2282002 ATG Information Work Order# 2282002 T VUNLEADED LAST GROSS TEST PASSED: NO TEST PASSED LAST PERIODIC TEST PASS: NO TEST PASSED FULLEST PERIODIC TEST PASSED EACH MONTH: TEST START TIME HOURS VOLUME % VOLUME TEST TYPE TANK LEAK TEST HISTORY T 2:PREMIUM LAST GROSS TEST PASSED: NO TEST PASSED LAST PERIODIC TEST PASS: NO TEST PASSED FULLEST PERIODIC TEST PASSED EACH MONTH: TEST START TIME HOURS VOLUME % VOLUME TEST TYPE TANK LEAK TEST HISTORY T 4:DIESEL LAST GROSS TEST PASSED: NO TEST PASSED LAST ANNUAL TEST PASSED: NO TEST PASSED FULLEST ANNUAL TEST PASS NO TEST PASSED LAST PERIODIC TEST PASS: NO TEST PASSED FULLEST PERIODIC TEST PASSED EACH MONTH: TEST START TIME HOURS VOLUME % VOLUME TEST TYPE 3 3 130100 JUN 29, 2011 3:01 PM VALERO 3074 3225 BUCK OWENS BAKERSFIELD,CA 93308 661- 324 -9481 LIQUID STATUS REPORT SENSOR LOCATION STATUS 1 PREMIUM STP SUMP SENSOR NORMAL 2 UNLEADED STP SUMP SENSOR NORMAL 3 UNLEADED INT SENSOR NORMAL 4 PREMIUM INT SENSOR NORMAL 5 DIESEL STP SUMP SENSOR NORMAL 6 DIESEL INT SENSOR NORMAL 7 FILTER SUMP SENSOR NORMAL 8 UNLEADED FVR SUMP SENSOR NORMAL 9 PREMIUM FVR SUMP SENSOR NORMAL 10 DIESEL FVR SUMP SENSOR NORMAL 130600 JUN 29, 2011 3:01 PM 3 3 131100 JUN 29, 2011 3:01 PM 3 3 134100 JUN 29, 2011 3:01 PM 3 3 134600 JUN 29, 2011 3:01 PM 3 3 134B00 JUN 29, 2011 3:01 PM 3 B9999FFlBL 3 137400 2282002 ATG Information JUN 29, 2011 3:01 PM B9999FF18o B9999FFIBo 2282002 Work Order# 2282002