Loading...
HomeMy WebLinkAbout2011 FMC RESULTSSlli // evV4--iS oti /,2,3 MONITORING SYSTEM CERTIFICATION For Use By All Jurisdictions Within the State ofCalifornia Authority Cited: Chapter 6 7, Health andSafety Code; Chapter 16, Division 3, Title 23, California Code ofRegulations This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner /operator. The owner /operator must submit a copy of this form to the local agency regulating UST systems within 30 days of this date. A. General Information Facility Name: #1001 Wholesale Fuels, Inc. Site Address: 2200 East Brundage Lane City: Bakersfield Facility Contact Person: Omero Garcia Make /Model of Monitoring System: Veeder -Root TLS -350 B. Inventory of Equipment Tested /Certified esChecktheappropriatebox to indicate specific equipment inspected /serviced: Bldg. No.: Zip: 93307 Contact Phone No.: 661 - 393 -7000 Date of Testing/Servicing: 9/30/2011 Tank ID: T -1 L -S Clear 10000 gallons Tank ID: T -2 L -S Dyed 10000 gallons U In -Tank Gauging Probe. Model: 847390-107 U In -Tank Gauging Probe. Model: 847390 -107 Annular Space or Vault Probe. Model: Annular Space or Vault Sensor. Model: Piping Sump / Trench Sensor(s). Model: Piping Sump / Trench Sensor(s). Model: Fill Sump Sensor(s) Model: Fill Sump Sensor(s). Model: Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: U Electronic Line Leak Detector. Model: Campo - Miller U Electronic Line Leak Detector. Model: Campo - Miller X] Tank Overfill / High Level Sensor. Model: 847390 -107 Tank Overfill / High Leval Sensor. Model: 847390 -107 Other (specify equip. type and model in Sec. E on Pg. 2) Other (specify equip. type and model in Sec. E on Pg. 2) Tank ID: T -3 Clear Diesel 20000 gallons Tank ID: TA Unleaded 20000 gallons x] In -Tank Gauging Probe. Model: 847390-107 In -Tank Gauging Probe. Model: 847390 -107 Annular Space or Vault Sensor. Model: Annular Space or Vault Sensor. Model: Piping Sump / Trench Sensor(s). Model: Piping Sump / Trench Sensor(s). Model: Fill Sump Sensors(s). Model: Fill Sump Sensor(s). Model: Mechanical Line Leak Decector. Model: Mechanical Line Leak Detector. Model: X] Electronic Line Leak Detector. Model: Campo-Miller Electronic Line Leak Detector. Model: Campo - Miller Fx] Tank Overfill / High Level Sensor. Model: 847390-107 Tank Overfill / High Level Sensor. Model: 847390 -107 Other (specify equip. type and model in Sec. E on Pg. 2) Other (specify equip. typs and model in Sec. E on Pg. 2) Dispenser ID: T -1 Clear Dispenser ID: _T -2 L-S Dyed Fx7 Dispenser Containment Sensor(s). Model: 794380 -208 xI Dispenser Containment Sensor(s). Model: 794380 -208 X] Shear Valve(s). U Shear Valve(s). Dispenser Containment Float(s) and Chain(s). Dispenser Containment Float(s) and Chain(s) Dispenser ID: T -3 Clear Diesel Dispenser ID: TA Unleaded Lx] Dispenser Containment Sensor(s). Model: 794380 - 208 U Dispenser Containment Sensor(s). Model: 794380 -208 fx] Shear Valve(s). Shear Valve(s). Dispenser Containment Float(s) and Chains(s). Dispenser Containment Float(s) and Chain(s). Dispenser ID: T -5 Dyed Dispenser ID: T-6 Dyed FX] Dispenser Containment Sensor(s). Model: 794380 -208 X] Dispenser Containment Sensor(s). Model: 794380 -208 L] Shear Valve(s). K Shear Valve(s). Dispenser Containment Float(s) and Chain(s) Dispenser Containment Float(s) and Chain(s). If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. C. Certification - I certify that the equipment identified in this document was inspected /seryices in accordance with the manufacturers' guidlines. Attached to this Certification is information (e.g. manufacturers' checklist) necessary to varify that this information is correct and a plot plan showing the layout of monitoring equipment. For equipment capable of generating such reports, 1 have attached a copy of the report; (check all that apply) x System Set -up Lx] Alar histo report Technician Name (print): Bradley Seykora Signature: ,/ s Certification No: 840738 License No: 804904 Testing Company Name: Confidence UST Services, Inc. Phone No: 800- 339 -9930 Site Address: 2200 East Brundage Lane , Bakersfield, CA 93307 Date of Testing/Servicing: 9/30/2011 MONITORING SYSTEM CERTIFICATION For Use By All Jurisdictions Within the State ofCalifornia Authority Cited.- Chapter 6 7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code ofRegulations This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner /operator. The owner /operator must submit a copy of this form to the local agency regulating UST systems within 30 days of this date. A. General Information Facility Name: #1001 Wholesale Fuels, Inc. Bldg. No.: Site Address: 2200 East Brundage Lane City: Bakersfield Zip: 93307 Facility Contact Person: Ornero Garcia Make /Model of Monitoring System: Veeder -Root TLS -350 B. Inventory of Equipment Tested /Certified Check the appropriate boxes to in mate specific equipment inspected /serviced: Contact Phone No.: 661 - 393 -7000 Date of Testing/Servicing: 9/30/2011 Tank ID: T-5 L -S Dyed 20000 gallons Tank ID: T -6 L -S Dyed 20000 gallons X] In -Tank Gauging Probe. Model: 847390-107 x] In -Tank Gauging Probe. Model: 847390 -107 Annular Space or Vault Probe. Model: Annular Space or Vault Sensor. Model: Piping Sump / Trench Sensor(s). Model: Piping Sump / Trench Sensor(s). Model: Fill Sump Sensor(s) Model: Fill Sump Sensor(s). Model: Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: X] Electronic Line Leak Detector. Model: Campo - Miller U Electronic Line Leak Detector. Model: Campo - Miller L] Tank Overfill / High Level Sensor. Model: 847390 -107 L] Tank Overfill / High Leval Sensor. Model: 847390 -107 Other (specify equip. type and model in Sec. E on Pg. 2) Other (specify equip. type and model in Sec. E on Pg. 2) Tank ID: (AST) T -7 L -S Dyed 20000 gallons Tank ID: (AST) T -8 Clear Diesel 12000 gallons x] In -Tank Gauging Probe. Model: x] In -Tank Gauging Probe. Model: Annular Space or Vault Sensor. Model: Annular Space or Vault Sensor. Model: Piping Sump / Trench Sensor(s). Model: Piping Sump / Trench Sensor(s). Model: Fill Sump Sensors(s). Model: Fill Sump Sensor(s). Model: Mechanical Line Leak Decector. Model: Mechanical Line Leak Detector. Model: Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: jx] Tank Overfill / High Level Sensor. Model: Lx] Tank Overfill / High Level Sensor. Model: Other (specify equip. type and model in Sec. E on Pg. 2) Other (specify equip. typs and model in Sec. E on Pg. 2) Dispenser ID: Dispenser ID: Dispenser Containment Sensor(s). Model: Dispenser Containment Sensor(s). Model: Shear Valve(s). Shear Valve(s). Dispenser Containment Float(s) and Chain(s). Dispenser Containment Float(s) and Chain(s) Dispenser ID: Dispenser ID: Dispenser Containment Sensor(s). Model: Dispenser Containment Sensor(s). Model: Shear Valve(s). Shear Valve(s). Dispenser Containment Float(s) and Chains(s). Dispenser Containment Float(s) and Chain(s). Dispenser ID: Dispenser ID: Dispenser Containment Sensor(s). Model: Dispenser Containment Sensor(s). Model: Shear Valve(s). Shear Valve(s). Dispenser Containment Float(s) and Chain(s) Dispenser Containment Float(s) and Chain(s). If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. C. Certification -1 certify that the equipment identified in this document was inspected /services in accordance with the manufacturers' guidlines. Attached to this Certification is information (e.g. manufacturers' checklist) necessary to varify that this information is correct and a plot plan showing the layout of monitoring equipment. For equipment capable of generating such reports, I have attached a copy of the report; (check all that apply) x System Set -up E Alarm histo eport Technician Name (print): Bradley Seykora Signature: Certification No: 840738 License No: 804904 Testing Company Name: Confidence UST Services, Inc. Phone No: 800 - 339 -9930 Site Address: 2200 East Brundage Lane, Bakersfleld, CA 93307 Date of Testing/Servicing: 9/30/2011 D. Results of Testing /Servicing Software Version Installed: 123.02 Complete the following checklist: x] Yes No* Is the audible alarm operational? x Yes No* Is the Visual alarm operational? x Yes No* Were all sensors visually inspected, functionally tested, and confirmed operational? x Yes No* Were all sensors installed at the lowest point of secondary containment and positioned so that other equipment will not interfere with their proper operation? LJ Yes No* If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) Hx N/A operational? x Yes No* For pressurized piping systems, does the turbine automatically shut down ifthe piping secondary N/A containment monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initate positive shut -down? E Sump /Trench Sensors [x] Dispenser Containment Sensors Did you confirm positive shut -down due to leaks and sensor failure /disconnected? U Yes; No; U Yes No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no r] N/A mechanical overfill prevention valve is installed), is the overfill warning alarm visual and audible at the tank fill point(s) and operating properly? If so, at what percent of tank capasity does the alarm trigger? 90 % Yes* U No Was any monitoring equipment replaced? If Yes, identify specific sensors, probes, or other equipment replaced and list the manufacturer name and model for all replacement parts in Section E, below. Yes* No Was liquid found inside any secondary containment systems designed as dry systems? Product; Water. If yes, describe causes in Section E, below. x No* Was monitoring system set -up reviewed to ensure proper settings? Attach set -up reports, if applicable. Lxj Yes 10 No* I Is all monitoring equipment operational per manufacturer's specifications? In Section E below, discribe how and when these deficiencies were or will be corrected. E. Comments: F. In -Tank Guaging / SIR Equipment: [X] Check this box if tank guaging is used only for inventory control. Check this box if tank guaging or SIR equipment is installed. This section must be completed if in -tank guaging equipment is used to perform leak detection monitoring. Complete the following checklist: X] Yes No* Has all input wiring been inspected for proper enter and termination,including testing for ground faults? x Yes No* Were all tank guaging probes visually inspected for damage and residue buildup? x Yes 7 No* Was accuracy of system product level readings tested? x Yes No* Was accuracy of system water level readings tested? x Yes No* Were all probes reinstalled properly? x] Yes I No* I Were all items on the equipment manufacturer's maintenance checklist completed? In the Section H, below, describe how and when these deficiencies were or will be corrected. G. Line Leak Detectors (LLD): Check this box if LLD's are not installed. Complete the following checklist: Cx] Yes No* For equip. start -up or annual equipment certification, was a leak simulated to varify LLD performance? Check all that apply) Simulated leak rate: [X]3 g.p.h.: 0.1 g.p.h.; 0.2 g.p.h.; Lx Yes No* Were all LLD's confirmed operational and accurate within regulatory requirments? x Yes No Was t e testing apparatus proper y ca i rate ? Yes No* For machanica LLD's, does the LLD restrict product flow if it detects a leak? x N/A x] Yes No* For electronic LLD's, does the turbine automatically shut off if the LLD detects a leak? N/A Fx] Yes No* For electronic LLD's, does the turbine automatically shut off ifany portion of the monitoring system is N/A disabled or disconnected? x] Yes No* For electronic LLD's, does the turbine automatically shut off if any portion ofthe monitoring system N/A malfunction or fails a test? Yes No* For electronic LLD's, have all accessible wiring connections been visually inspected? N/A x 'Yes No Were all items on the equipment manufacturer's maintenance checklist completed? In the section H, below, describe how and when these deficiencies were or will be corrected. H. Comments: WHOLE :;F;l_E FUELS2200EBRO19DAGEBAKERSFIELDCA93304 SEP 30. 2011 7:49 tvl SYSTEM- STHTUS REPORT - ALL FUNCTION:: NORMAL INVENTORY RET'OR'T' T 1:L -S CLEAR VOLUME e 794:1 GALSULLAC:E - 2056 GALS90. ULLAGE- 1056 CALSTCVS }LI.41E tr 7838 GALSHEIGHT70.38 INCHESWATERVOL0 -;ALSWATER30.00 11v_HESTEMPa89.5 DEG F T : L -: DYED VOLUME 16884 GOALS ULLAGE _ 5G23 GALS 1377 GALS90% ULLAGE- 3377 GALSTCVOLUME = 5550 GALSHE1GHT = 52. 16 1 FICHESWATERVOL - 0 GALSWATER, = 0.00 INCHESTEPIP = 88.7 DEG F T 3 : CI.EAP D I ESEL VOLUME - 10243 GALSULLAC;E - 10320 Cml-S 90% ULLAj. E= 8263 CALSTCVOLUI -IE - 10108 GALS HEIGHT - 59.82 INCHESWATERVOL - 0 1:4ALSWATER0.00 1NCliCSTEMPv89. a DEG F T 4: UNLEADED VOLUME = 16884 GOALS ULLAGE = 3679 CALS 90"/. ULLAGE- 1622 i;ALS TC VOLUME - 1652R GHLS HEIGHT = 91 .82 1PICH SWATERVOL - 0 C:HLSWATER0.00 1 NcHI:STEMP = 90.1 DEG F T 5:L -S DYED VOLUME - 18427 GALSULLAGE2136GALS SYSTE1'I SETUP 9CM ULLAGE- 79 GALSTCVOLUME - 18181 GALS SEP 30 2011 50 AM HEIGHT - 100.72 1NCHES WATER VOL - 0 GALWATERm0.00 INCHESTEMP - 89.6 DES : F SYSTEM UN I TS U.S. SYSTEM UANGUA,E T 6:L-.c; DYED ENGLISH VOLUME 19761 GALS SYSTEM DATE,-TIME FORMAT ULLAGE 802 GALS MON DD 1 ^,'1^1 HH:MhI:SS :.hi 90% ULLAGE- 0 GALS TO VOLUME - 19497 GALS WHOLE SALE FUELS HEI13HT - 110.14 1NCHES 2200 E BRUNDAGE WATER VOL - 128 GALS BAY+ERSFIELD CA 6IATER = 2.88 INCHES 93304 TE1•IP e 89.7 DES; F SHIFT TIME 1 I 1: 00 P19 SHIFT TIME 2 12:00 AM T 7:1. -S DYED SHIFT TIME 3 1:00 AM VOLUME = 17723 GALS SHIFT TIME 4 2:00 All ULLAGE _ •2940 GALS 9rr4 ULLAGE 783 GALS TANK PER TST NEEDED I.,IRN TO VOLUME - 17506 GALS DISABLED HE :.HT - 96.51 1NCHE; TANK ANN TST NEEDED WRN WATER VOL - 18 GALS Ul24REE0 WATER. = 0.80 INCHES TEMP = 87.2 DEC F LINE RE- ENABLE METHOD PASS LINE TEST r 8 ! CLEAR D I ESEL I.1 IvE PER TST NEEDED WRN VOLUME = 8115 GALS DISABLED ULLAGE = 3885 GALS LINE ANN TST NEEDED WRN 90% ULLAGE= 2685 GALS DISABLED TC VOLUME = 8026 GALS HEIGHT = 61.47 I h1CHES PR 114T TC VOLLIMES WATER VOL - 0 GALS ENABLED WATER - 0.00 INCHES TEMP = 84.4 DEG F TEMP COMPENSATION VALUE (DEG F ): 60.0 ST1C.I( HEIGHT OFFSET v _ n END t. Y K DISABLED H- PROTOCOL DATA FORMAT HEIGHT PRECISION TEST DURATION HOURS: 1 ^c 0.20 (,PH LINE TEST AUTO - CONFIRM: ENABLED 0.10 GPH LINE TEST AUTO-CONFIRM: ENABLED PRINT PRECISION LINE TEST RESULTS: DISABLED SOFTWARE REVISION LEVEL DA' ,'L I GHT SAV 1 Nf; TIME VERSION 123.02 DISABLED SOFTWAREtr 345123 140-C RE- DIRECT LOCAL PRINTOUT CREATED - 02.11.25.15.17 DISABLED S- HODULEd 330160-062 A EURO PROTOCOL PREFIX SYSTEM FEATURES: S PERIODIC I N -TmlgK TES'T'S ANNUAL IN-TANK TE!: 1'S ' CSLD PLLD SYSTEM SECURITY 0.10 AUTO CODE : 000000 0.20 P.EPETITIV WPLLD CUSTOM ALARM LABELS 0.10 AUTO DISABLED 0.20 REPETITIV COM•tUN I CAT I DNS SETUP IN-TANK SETUP T 2 : L -S DYED PRODUCT CODE 2 THERMAL COEFF :.000450 PORT SETTINGS: T I:L -S CLEAR TANK DIAMETER 95.0 PRODUCT CODE I TANK PROFI PT 001'" BOARTJ 1 [RS -2;;2) THERMAL COEFF :.000456 FULL VOL 16000 BAUD RATE 9600 TANK DIAMETER 55.00 PARITY NONE STOP BIT : I STOP TANK PROFILE FULL VOL I PT 10000 FLOAT SIZE: 4.0 N. DATA LENGTH: 8 DATA RS -232 SECURITY WATER WARNING 4.0 CODE DISABLED FLOAT SIZE: 4.0 IN. HIGH WATER LIMIT: 5.0 WATER WAR14ING 4,0 MAX OR LABEL VOL: 10000 AUTO TRANS'MlT SETTINGS HIGH WATER LIMIT: 5.0 OVERFILL LIMIT n0 AUTO LEAK ALARM LIMIT P'IAX OR LABEL. VOL: 10000 HIGH PRODUCT a95 %: 500DISABLED AUTO HIGH bJATER L fl I I T OVERFILL LIMIT 90 9000 DELIVERY LIMIT 1% DISABLED H I GH PRODUCT 95 %:, 100 DITTO OVERFILL L1r1IT DISABLED DELIVERY LIMIT 9500 1% LOW PRODUCT 0 AUTO L441 PRODUCT 100 LEA)( ALARM LIMIT: 75 DISABLED SUDDEN LOSS LIMIT: 99 AUTO THEFT L1111T LOW PRODUCT 0 75 TANK TILT PROBE OFFSET 95 0.00DISABLEDLEA: ALARM LIMIT: AUTO DELIVERY STl:1RT SUDDEN LOSS L I MI T: 99 DISABLED DELIVERY END TANY. TILT PROBE OFFSET 2.40 0.00 SIPHON F1A11 I FOLllED TANK'S DISABLED TO: NONE AUTO EXTERNAL II4PLIT ON LINE MA141FOLDED TANKS Td: NONEDISABLEDSIPHONMANIFOLDEDTANKS AUTO EXTERNAL INPUT OFF TO: NONE DISABLED LINE MANIFOLDED TANKS TO: NONE LEAK i'iiN PERIODIC: I0% AUTO SENSOR. FUEL ALARM k000DISABLED AUTO SENSOR WATER ALARMDISABLED LEAK 11IN PERIODIC: 10: LEAK N I N ANNUAL : 10% AUTO SENSOR OUT w.ARM Inno 1000 DISABLED LEAK MIN ANNUAL 10% 1 000 PER I OC, I C TEST TYPE STANDARD PERIODIC TEST TYPE ANNUAL TEST FAIL STANDARD ALAF.41 DISABLED ANNUAL TEST FAIL PERIODIC TEST FAIL F`3 -232 END OF MESSHCE ALARM DISABLED ALARM DISABLED DISABLED PERIODIC' TEST FAIL GROSS TEST FAIL ALARM DISADLED ALARM DISABLED GROSS TEST FAIL ANN TEST AVERAGING: OFF ALARPI D i SABLED PER 'PEST AVERAG I NG : OFF ANN TEST AVERAGING: OFF TANK TEST NOTIFY: OFF PER TEST AVERAGING: OFF TNK TST SIPHON BREAK:OFF TANK TEST NOTIFY: OFF DELIVERY DELAY 1 MIN TNK TST SIPHON BREA;:OFF PUMP THRESHOLD 10.00% DELIVERY DELAY 1 1,1114 PUMP THRESHOLD 10.00% T 3:CLEAR DIESEL T 4:UNLEADED T 5:L -S DYED PRODUCT (:ODE 3 PRODLr.T CODE 4 PRODUCT CODE 5 THERMAL 1'OEFF :.000450 THERMAL COEFF :.000700 THERMAL COEFF :.000450 TANK DIAMETER 120.00 TANK DIAMETER 120.00 TANK DIAMETER 120.00 TANK, PROFILE 1 PT TANK PROFILE 1 PT TANK PROFILE 1 PT FULL VOL 20563 FULL VOL 20563 FULL VOL 20563 FLOAT SIZE: 4.0 IN. FLOAT SIZE: 4.0 1N. FLOAT SIZE: 4.0 IN. WATER WmRIN 114G 14.0 WATER WARN I NG 4.0 WATER. WAR141 NG 4.0 HIGH WATER LIMIT: 5.0 HIGH WATER LIMIT; 5.0 HIGH WATER LIMIT: 5.0 MAX 09 LABEL VOL: 21151;3 MAX OR LABEL VOL: 20563 MAX OR LABEL VOL: 20563 OVERFILL LIMIT 90;6 OVERFILL LIMIT 90- OVERFILL LIMIT 90% 18506 18506 18506 HIGH PRODUCT 95°, HIGH PRODUCT 95% HIGH PRODUCT 95k 19535 19535 1951: DELIVERY LIMIT I'. DELIVERY LIMIT DELIVERY LIMIT 05205 I 205 LOW PRODUCT 0 LOW PRODUCT 0 LOW PRODUCT : 0 LEAK ALARI•I LIMIT: 75 LEAK. ALARM LIMIT: 75 LEAK ALARM LIMIT: 75 SUDDEN LOSS LIMIT: 200 SUDDEN LOSS LIMIT: 99 SUDDEN LOSS LIMIT: 99 TANK TILT 0.50 TANK TILT 3.00 TANI; TILT 0.00 PROBE OFFSET 0.00 PROBE OFFSET 0.00 PROBE OFFSET 0.00 SIPHON MANIFOLDED TANKS SIPHON MANIFOLDED TANKS SIPHON MANIFOLDED TANKS Td: 14014E TO: NONE TO: NONE LINE MANIFOLDED TAI4YS LI14E MANIFOLDED TANKS LINE MANIFOLDED TANKS Tn: NONE Ta: NONE TO: N014E LEAK MIN PERIODIC:: 10:: LEAK MlN PERIODIC: I0%: LEAK MIN PERIODIC: 10:: 2056 2056 2056 LEAK MIN ANNUAL I0`. LEAK MIN ANNUAL IOs. LEAK MIN ANNUAL 101". 2056 2056 2056 PERIODIC TI-EST TYPE PERIODIC TEST TYPE PERIODIC TEST TYPE STANDARD STANDARD STANDARD ANNUAL TEST FAIL ANNUAL TEST FAIL ANNUAL TENT FAIL ALAPH DISABLED ALARM DISABLED ALARM DISABLED PERIODIC TEST FAIL PERIODIC TEST FAIL PERIODIC TEST FAIL ALARM DISABLED ALARM DISABLED ALARM DISABLED CROSS TEST FAIL ROSS TEST FAIL GROSS TEST FAIL ALARM DISABLED ALARM DISABLED ALARM DISABLED ANN TEST AVERAGING: OFF ANN TEST AVERAGING: OFF ANN TEST AVERAGING: OFF PER TEST AVERAGING: OFF PER TEST AVERAGING: OFF PER TEST AVERAGING: OFF TANK TEST NOTIFY: OFF TA14K TEST NOTIFY: OFF TA14K TEST NOTIFY: OFF TNK TST SIPHON BP.EA)::OFF TNK TS•f SIPHON BP.EAK:OFF TNK TST SIPHON BP.EAK:OFF DELIVERY DELAY 1 1.1114 DELIVERY DELAY 1 MIN DELIVERY DELAY 1 MIN PUMP THRESHOLD : 10.00 %: PUMP THRESHOLD 10.00•%, PUMP THRESHOLD 10.001-- T G: L -S DYED T 7:L -S DYED PRODUCT CODE 7 T B:CLEAP. DIESEL 8 PRODUCT :ODE 6 THEP,MAL COEFF :.000450 PRODUCT CODE THERMAL COEFF :.000450THERMALCOEFF :.000450 TANK DIAMETER 120.00 TANK DIAMETER 96.00TANK1) 1AMETER 120.00 TANK PROFILE 1 PT TANK PROFILE 1 PTTANKPROFILEIPTFULLVOL2'17563 FULL VOL 12000FULLVOL20563 FLOAT SIZE: 4.0 IN. FLOAT SIZE: 4.0 IN. FLOAT SIDE: 3.0 IN. WATEP. 4.0 WATER WARN I NG : HIGH WATER LIMIT: 4.0 5.0 WATER WARM I I4G : 4.0 5.0HIGHWATERL1N11T: WATER 5.0 HIGH WATER LIMIT: MAX OR LABEL VOL: 0 G3 MAX OR LABEL VOL: OVERFILL LIMIT 20563 0 ° MAX OR LABEL VOL: 12000 90%, OVERFILL LI III lT 901 18506 O ERF 1 LL LIMIT 1080018506HIGHPRODUCT95% HIGH PRODUCT 95.E HIGH PRODUCT 94% 19535 1195% DELIVERY LIMIT 20357 1% DELIVERY LIMIT 2 5 DELIVERY L1111T 1% 205 205 LOW PRODUCT : 0 LOW LEAY, RODUCTLIMIT: 75 LOW PRODUCT : LEAK ALARM LIMIT: 70 LEAK ALARM LIMIT: 75 SUDDEN LOSS LIMIT: 99 SUDDEN! LOSS LIMIT : 99 SADDEN LOSS LIMIT: TILT 99 TANK TILT 0.00 TANK TILT - 5.00 TANK 3.00 PROBE OFFSET 0.00 PROBE OFFSET 0.00PROBEOFFSET0.00 SIPHON MAN I FOLDED 'TANKS TO: NONE LINE PLAN I FOLDED TANKS T4: NONCE LEAK MIN PERIODIC: 101. 2056 LEAK MIN ANNUAL 10% 205E PERIODIC TEST TYPE STANDARD ANNUAL TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARN,1 DISABLED GROSS TEST FAIL ALARM DISABLED ANN TEST AVERAGING: OFF PER TEST AVERAGING: OFF TANK TEST NOTIFY: OFF TNK: TST SIPHON BREAK :OFF DELIVERY DELAY 1 MIN PUMP THRESHOLD 10.00 SIPHON MANIFOLDED TAN)"S Tit: NONE LINE MANIFOLDED TANKS Td: NONE LEAK MIN PERIODIC: IO 2056 LEAK MIN ANNUAL 10'/ 2056 PERIODIC TEST TYPE STANDARD ANNUAL TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED GROSS TEST FAIL. ALARM DISABLED ANN TEST AVERAGING: OFF PER TEST AVERAGING: OFF TANK. TEST NOTIFY: OFF TNK TST SIPHON BREAK:OFF DELIVERY DELAY 1 MIN PUMP THRESHOLD 10.00'%o 0 SIPHON MANIFOLDED TANKS TO: NONE LINE MANIFOLDED TANKS TO: NONE LEAK MIN PERIODIC: 2056 LEAK MIN A14NUAL 217% PERIODIC TEST TYPE STANDARD AiVNIJAL TEST FAILALARMDISABLED PERIODIC TEST FAIL ALARM DISABLED GROSS TEST A`ARM I) I SABLED ANN TEST AVERAGING: OFF PER TEST AVERAGING: OFF TANK TEST NOTIFY: OFF TNK TST SIPHON BF'EriK:OFF DELIVERY DELAY I hIIN PUMP THRESHOLD 10.00°. LEmY TEST METHOC, TEST CSLD T'FHNI: I Pd - 95% CLIMATE FACTOR : EXTREME EVAP G014P : NO GROSU TEST AUTO- CONFIRM: DISABLED REPORT ONLY: END OF I tONTH TST EARLY STOP : C,1 SADLEV, TEST C:SLE, TANK 2 Pd s ?5%.. CLIMATE FA,_TOR : EXTREME EVAP COMP: NO GROSS TEST AUTO- CONFIRM: DISABLED REPORT 014L%': END OF MONTH TST EARLY STOP : D 1 Sf -* (BLED TEST CSLD TANK 3 Pd - 95% CLIMATE FACTOR : E;TP.EME EVAP COMP: NO GROSS TEST AUTO-CONFIRM: D i 3ABLI_D REPORT ONLY: END OF MONTH TST EARLY ST'0N : D 1 S(-%bL.ED TEST CSLO : TANK 4 Pd = 95`s CL 1MATE FAC'TJR : F,APEME FVAP COMP: I,10 GROSS TEST AUTO -CONF i Ril : V I S1ABLED REPORT ONL`; : END OF HOI4TH TST RARLY STOF• : D 1 GABLFL, TEST O'SLD TGd4H: 5 Pd - 95% CL I m fE FACTOR : EYTR1:ME EVAP COMP: Nl) r.,ROSS: TEST H11TO- CONFIRM : D l 2ABLEG REPORT ONLY: ENT? OF MONTH TST EARL`: STOP : E,1 GASLEO TEST C.SLE, TANK E Pd - 95`. CL I MmTE FACTOR : E)1'REME EVAP COMP: NO i:P0S. S TESf AUTO-CONFIRM: 111 StiBLED REPORT ONLY: EN17 OF MONTH TST EARLY STOP:DISABLED TEST ON DATE : TANK 7 APP. 22. 2011 START TIME : 3:52 mH TEST FATE :0.20 OMI..,/HR DURATION 2 !TOURS TST EARLY STOP:DISABLED TEST ON DATE : TANK 8 APR 22. 2011 START TIME : 3 :52 AM TEST RATE :0.20 GAL /HR DURATION : 2 HOURS TST EARLY STOP:DISABLED LEAK TEST REPORT FORMAT NORMAL PRESSURE LINE LEAK SlyFUP 0 1 : L. -S CLEAR. TYP:2.0.-3.01N FIBERGLASS 2.01N DIA LEN:500 FEET 3.0IN DIA LEN :200 FEET 0.20 GPH TEST: P.EPETITIv C1.10 GPH TEST: AUTO sHUfDOWN PATE: 3.0 GPH 1.014 PRESSURE SHUTOFF : NO LOW PRESSURE 0 PSI T I:L-S CLEAR, DISPENSE MODE: STANDARD SENSOR: NON- VENTED PRESSURE OFFSET: 5.OPS :1 0 2:L -S DYED TYP : 2.0,, 3.0 I N F T 13ERGL,kSS ' 1,.0114 DIrA LE14'.500 FEET 3.01N DIA LEN:200 FEET 0.20 C :PH TEST: REPET I T I V 0.10 OPH TEST: AUTO SHUTDOWN RATE: 3.0 GPH LOW PRESSURE SHUTOFF:NO LOW PRESSURE 0 PSI T 2:L-S DYED DISPENSE MODE: STANDARD SErVSOP NON- VENTED PRESSURE OFFSET: 5.OPS1 Q 3:CLEAR DIESEL TYP : 2.0/3.0I N F I BEP.,aL.ASS 2,01N DIA LEN:400 FEET 3.01N Dim LEN:-700 FEET 0.20 GPH TEST: REPETITIV 0.10 GPH TEST: AUTO SHUTDOWN RATE: 3.0 GPH LOW PRESSURE SHUTOFF:NO LOW PRESSURE : 0 PSI T 3:CLEAR DIESEL DISPENSE MODE: STANDARD SENSOR: NON - VEN'T'ED PRESSURE OFFSET: 5.OPS1 0 4:UNLEADED TYP : 2.0/3.0114 F I E+ERGLA:SS z.01N DIA LEN :500 FEET3.01N DIA LEN:200 FEET 0.20 GPH TEST: REPETITIV 0.10 GPH TEST: AUTO SHUTDOWN RATE: 3.0 GPH LOW PRESSURE SHUTOFF: 140 LOW PRESSURE : 0 PSI T 4:UNLEADED DISPENSE MODE : STANDARD SENSOR: NON- VENTED PRESSURE OFFSET: 5,0PS1 0 5:1.. -S DYED TYP:2.0 /3,01I9 FIBERGLHSS 2.01N DIA LEN:500 FEET 3.0114 DIN LEN:200 FEET 0,21) GPH TEST: REPETITIV 0.10 G.PH TEST: AUTO SHUTDOWN RATE: 3.0 GPH LOW PRESSURE SHIJTOFF : NO LOW PRESSURE : 0 PSI T 5:L -S DYED PISPENSE MODE: STANDARD SENSOR.: NON - VENTED PRESSURE OFFSET: 5.OPS1 A 6:L -S DYED OUTPUT RELAY SETUP RE-- CILIA SETUP - T`IP:2.0 /3.01N FIBERGLAETS fiIN DIA L.EN:500 FEET R I:SHUTDOWN EPA AUTOMATIC DAILY CLOSING 3.01N DIA LEN:100 FEET TYPE: TIME: 2:00 AM 0.20 GPH TEST: REPETITIV STANDARD 0.10 GPH TEST: AUTO NORMALLY OPEN PERIODIC RECONCILIATION SHUTDOWN RATE: 3.0 r ;PH MODE: MONTHLY LOW PRESSURE SHUTOFF :IJO LOW PRESSURE 0 PSI IN -TANK ALARMS TEMP COMPENSATIONALL:LEAY, ALARM STANDARD T 6: L -S DYED T 7:OVERF I LL ALARr-1 DISPENSE MODE: BUS SLOT FUEL DIETER TANK STANDARD R 2:OVERFILL ALARM SENSOR: NON- VErITED TYPE TANK MAP EMPTY PRESSURE- OFFSET: 5.0PSI STANDARD NORMALLY OPEN I N -TANK ALARPI_S Al_L : OVERF 1 LL ALARM ALL:HIGH PRODUCT AL .oRr•1 ALL :MAX PRODUCT ALARM LIOUID SENSOR ALMS ALL:FUEL ALARM ALL:SENSOR OUT ALARM ALARM HISTORY REPORTALL:SHORT ALARM SENSOR ALARM - - - -- LINE LEAK LOC}; OLI'I' SETUP R 3:PANS 1.23 L I : PANSTYPE: DISPENSER PAN LOC}:OUT SCHEDULE STANDARD FUEL ALARM DAILY NORMALLY CLOSED FEB 21. 2011 9:22 AM START 1' 11.1E : DISABLED STOP TIME DISABLED SENSOR OUT ALARMLIQUIDSENSORALMSFEB21, 2011 9:21 AMLI :FUEL ALARM L 3:FUEL ALARM FULL ALARMLI:SENSOR OUT ALARM FEB 21. 2011 9 :15 AML3:SENSOR OUT ALARM L I:SHORT ALARM L 3:SHORT ALARM R4:PAN- -j 4.5.6 TYPE: STANDARD NORMALLY CLOSED I. I ou I D SENSOR SETUF LIQUID SENSOR ALMS r. >: k END L I :PANS L 2:FUEL ALARM NORI,WLL`! CLOSED L 2:SENSOP. OUT ALARM CATEGORY : DISPENSER PAN L 2:SHOP.T ALARM L 2: PANS NORMALLY CLOSED CATEGORY : DISPENSER PAN ALARM HISTORY REPORT L 3:PANS NORMALLY CLOSED PLLD LINE DISABLE SETUP --- -- SENSOR ALARM ----- CATEGORY DISPENSER PAN _ _ L 2:PANS DISPENSER PAN 0 I : L -S CLEAR FUEL ALARM NO ALARI ASSIGNMENTS - FEB 18. 2011 11:54 AM P FUEL ALARM 0 2:1 - -5 DYED FEB 18, 2011 9 :30 AM NO ALARM ASSIGNMENTS - FUEL ALARM DEC 18, 2010 4:16 P11 C1 1:('I-EAR DIESEL NO ALARM ASS I GNNENT:= - A 4 :UNLEADED NO ALARM ASSICNMENTS - 0 5:L -S DYED NO ALARM ASSIGNMENTS - Y x x x END r 0 6 :L -S DYED 1,10 ALARM ASSIGNMENTS - IN-TANK ALARM - - - -- T 6:1_ -S D'E'ED PROBE OUT SEP 30, 2011 0:30 AM s s END IN-TANK (ALARM - - - -- T 6:L -S DYED PROBE OUT SEP 30. 217111 8:35 AM WHOLE SALE FUELS 2200 E BRUNDAGE BAKERSFIELL, CA ALARM HISTORY REPORT 93304 SEP 30. 2011 8:31 AM L a OTHER SEN..S-DRS SYSTEM STATUS REPORT - - -- IN -TANK. ALARM - - - -- T 4:UNLEADED ALL FUNCTIONS 14OR11AL SUDDEN LOSS ALARM SEP 30. 2011 8:37 AM a ,v, E Nll IN -TANK ALARM - - - -- T 6:1 DYED -- -- IN -TANY ALARM - - - -- OVERFILL ALARM T 3: :LEAK DIESEL SEP 30, 2011 8:33 AM SUDDEN LOSS ALARM SEP 70, -011 8:37 AM ARi>l I VE U'1" I L I Ty SAVE SETUP DATA: START T l i °IC : SEP 30. 2011 7:5,1:39 AM - - -- 1N -TANK ALARM - - - -- T b:L -S 11YED - - -- 114 -TAIVK ALARM - - - -- MAX PRODUCT ALARM T 4:UNLEADED SEP 30. 2011 8:33 AM PROBE OUT SEP 30. 2011 8:37 AM I N -TANK. ALARM - - - -- - I N -TANI! ALARM - - - -- T 5:L -S DYED T DIESEL3:CLEARSUDDEI4LOSSALARMPROBE EAR SEP 30. 2011 8:31 AM SEP 30. 2011 8:37 AM IN-TANK T 6: L -S DYED T 6:1--S, DYED I NVENTORY I NCREASE SUDDEN LOSS ALARM INCREASE STARTSEP30. 2011 8:27 Am SEP 30, 2011 8:32 AM VOLUME n 15142 GALS HEIGHT = K. 84 INCHES ALARM HISTORY REPORT WATER - 0.00 INCHES TEMP = 90.1 DEG F SEI4SOR ALARM - - - -- L 3: PANS: DISPENSER PAN INCREASE END FUEL ALARM IN -TANI: ALARM _____ SEP 30. 2011 8:35 AM APR 25. 2011 11:50 AM T 6:L -S DYED PROBE OUT VOLUME 20092 GALS FUEL ALARM SSEP 3U. 2Otl 8:2, All HEIGHT =113.12 IIW;HES FEB 28. 2011 6: 15 All WATER 0.00 1I4CHES TEMP = 90.6 DEC: F FUEL ALARM DEC 19, 2010 4:14 AM GROSS INCREASE- 4950 TC NET INCREASE= 4878 IN-TANK ALARM - - - -- T 6:1_ -S D'E'ED PROBE OUT SEP 30, 2011 0:30 AM s s END IN-TANK (ALARM - - - -- T 6:L -S DYED PROBE OUT SEP 30. 217111 8:35 AM WHOLE SALE FUELS 2200 E BRUNDAGE BAKERSFIELL, CA ALARM HISTORY REPORT 93304 SEP 30. 2011 8:31 AM L a OTHER SEN..S-DRS SYSTEM STATUS REPORT - - -- IN -TANK. ALARM - - - -- T 4:UNLEADED ALL FUNCTIONS 14OR11AL SUDDEN LOSS ALARM SEP 30. 2011 8:37 AM a ,v, E Nll IN -TANK ALARM - - - -- T 6:1 DYED -- -- IN -TANY ALARM - - - -- OVERFILL ALARM T 3: :LEAK DIESEL SEP 30, 2011 8:33 AM SUDDEN LOSS ALARM SEP 70, -011 8:37 AM ARi>l I VE U'1" I L I Ty SAVE SETUP DATA: START T l i °IC : SEP 30. 2011 7:5,1:39 AM - - -- 1N -TANK ALARM - - - -- T b:L -S 11YED - - -- 114 -TAIVK ALARM - - - -- MAX PRODUCT ALARM T 4:UNLEADED SEP 30. 2011 8:33 AM PROBE OUT SEP 30. 2011 8:37 AM I N -TANK. ALARM - - - -- - I N -TANI! ALARM - - - -- T 5:L -S DYED T DIESEL3:CLEARSUDDEI4LOSSALARMPROBE EAR SEP 30. 2011 8:31 AM SEP 30. 2011 8:37 AM T 5:L -S DYED 1N -TANK ALARM - - T I:1 --5 CLEAR 114VE14TORti I IVCREAr(E T I: L -S CLEAR I NVENTORY I NCREASE I NCREASE Sl'raRT PROBE OUT 30 • 2011 8 : 14 AM 1 NCREASE START EP 30. 2'01 1 8:34 Ah1 SEP SEP 30. _Olt 8: 46 Art VOLUME - 16758 ' ;ALS VOLUME - 4281 GALS HEIGHT - 91.15 114CHES HEIGHT - 42.12 1NCHES WATER - 0.76 1Nr_HES WATER = 0.00 INCHES TEMP - 88.r DEG F TEMP - 88.8 DEG F 114CREASE END INCREASE END SEP 30. 2011 8:37 All IN -TANK ALARM -____ SEP 30. 2011 8:53 AM VOLUME - 18393 i ALS I' I : L -S CLEAR INVALID FUEL LEVEL VOLUME - 9591 GALS HEIGHT - 100.51 1NCHES SEP 30. 2011 8:45 AM HEIGHT - 86.93 INCHES WATER - 0.00 INCHES WATER - 0.00 INCHES TEMP - 89.6 DEG F TEMP = 90.1 DEC F GROS t I IvC:REASE- I i:,35 GROSS I ti 531 l 1'C NET INCREASE- 1607 TC NET INCREASE- 5235 T 3:01.EAR DIESEL INVENTORY INCREASE INCREASE START SEP 30. 2011 •8:41 AM VOLUME - 1671 CALS HEIGHT - 16.27 INCHES tIV -TAN), ALARM - - - -- WATER - 7.18 INCHES TEMP o 88.3 DEC F IN -TANK ALARM - - - -- T CLINLEADED T 4;L -c; DYED HIGH PRODUCT ALARM SUDDEN LOSS ALARM SEP 30• ='011 E:39 AM INCREASE END SEP 30. 2011 8:53 AM SEP 30. 2011 8:46 AM VOLUME - 18842 GALS HEIGHT - 103.39 INCHES WATER - 0.00 INCHES TEMP - 90.0 DEG F IIV -THNk: ALwF99 - - - -- GROSS INCREASE- 17171 TC NET 1NCP.EASE= 16938 IN -TANK ALMRIM - - - -- T 4:UNLE•ADED T 2:L -S DYED LOW TEMP WARNING PROBE OUT SEP 30. :'011 8:39 AM SEP 30. 2011 8:54 AM IN -TANK ALARM - - - -- - --- 1 N -TAN 1' a: iiNL EODED - IN-TANK' ALARM -- - -- Y ALrtiRM - - --- T I: :L-S' ClEAR T 2: L -S DYED PROBE OUC 114VALID FUEL LEVEL SSEP30, 2011 8:39 AM IPH PRODUCT ALARI'1 SEP 30. 2011 8:47 AM SEP 30. 2011 8:55 AM I N -TANK Al..MR11 - - - -- 1 rt -TANK ALARM T 3:LLEAP. DIESEL - IN- TArI}; ALARM -- - -- T 2 :L -S DYED - -- - OVEP,FILL ALARM T I: FIL CLEAR HIGH PRODUCT ALARM SEP 30. 2011 8:42 Art OVERFILL ALARM SEP :0. 2011 8:56 AMSEP30. 2011 8:47 AM IN -TANK ALARM --- IN -TANK ALARM - -- -- -- IN -TANK AL;,RrI - - - -- T 3:CLEmR DIESEL T I:L -g :LEAP. T 2:L-c3 DYED PROBE OUT PROBE OUT SUDDEN LOSS ALARM SEP 30. 2011 8:42 AM SEP 30, 2011 8:47 AM SEP 30. 2011 8:56 AM I N -TANI; ALARM - -- -- T 2:1. -S DYED 6IHOLE SALE FUELS 61HOLE SALE FUELS PROBE OUT 2200 E BRUNDACE 2200 E BRUNDAGE SEP 30. 22011 8:57 AM BAKERSF I ELD CA BA);EP.SF I ELD CA9330493304 T 2:L.-::.; DYED I NVI? PRESSURE LINE LEAK ALARM06 :L -S DYED CROSS LINE FAILSEP30. 201, 11:01 AM PRE5SUR1: LINE LEAK ALARM74b :L -S DYED PLLD SHUTDOWN ALAFtlSEP30. 2011 11:01 AM WHOLE SALE FUELS2200EI3RUPIDA,.:kBAKERSF1ELDCA9330'1 SEP 30. 2011 11:40 Ahl SYSTEM STATUS REPORT 0 6:0ROSS LINE FAIL 0 6 :PLLD SHUTDOWN ALARM PRE' SURE LINE LEmY ALARM 0 2:L -S DYED GROS'S LINE FAIL SEP 30, 2011 12:12 PM PRESSURE LINE LEAK ALARM 0 3:CLEAR DIESEL GROSS LINE FAIL SEP 20, 2011 11:55 AH PRESSURE LINE LEAK. ALARM G 2:1--S. DYED PLLD SHUTDOWN ALARM SEP 30. 2011 12:12 PM PRESSURE LINE LEAK ALARM 0 3:CLEAR DIESEL PLI-D SHUTDOWN ALARM SEP 30. 2011 11:55 AM WHOLE SALE FUELS 2200 E BRUNDAGE BARERSFIELD CA 93304 SEP 30. 2011 12 :54 PM SYSTEM STATUS REPORT 0 2:GROSS LINE FAIL Q 2:PLLD SHUTDOWN ALARM 0 3:GROSS LINE FAIL 0 3:PLLD SHUTDOWN ALARM WHOLE SALE FUELS 2200 E BRUNDAGE BAKEF.'SFIELD CA 93304 PRESSURE LINE'LEAK ALARM SEP 30. 2011 12:53 P1i01:1--S CLEAR GROSS LINE FAIL SEP 30. 1011 12:02 PM SYSTEM STATUS REPORT 0 I :GROSS LINE FAIL 0 I : PLLD SHUTDOWN ALARM 0 2:C:P.OSS LINE FAIL PRESSURE LINE LEAK, ALARM W 2 :F'LLD SHUTDOWN ALARM 0 1:L`S CLEAR PLLD S7HUTDOWN ALARM 3:uROSS LINE FAIL SEP 30. 2011 12:02 Pm 0 3:PLLD SHUTDOWN ALARM WHOLE SALE FUELS 2200 E BRUNDAGE BARERSFIELD CA 93304 SEP 30. 2011 12 :54 PM SYSTEM STATUS REPORT 0 2:GROSS LINE FAIL Q 2:PLLD SHUTDOWN ALARM 0 3:GROSS LINE FAIL 0 3:PLLD SHUTDOWN ALARM WHOLF. SALP FUELS 2200 E SRUNDrI,.E BAKERSF I ELI) Cap 9331 4 SEP 30. 20)t 12:57 PM SYSTEM STATUS REPORT 0 1: GP.OSS LINE I'A I L r~ 0 3 :PLLD SHUTDOWN ALARM PRESSURE LINE LE,-,iY: ALARM45:L -S DYED PERIODIC LINE FAIL SEP 30, 2011 1 :()4 F,M PRESSURE L I NE LEAP. ALARM1 : rJIVI_EADEC GRQfiS LINE FAIL EP 30. ,ol l I :12 PI•I FRE:St IFE L 1 NE LEF K riLraRl"I UNLEmDEC, F'LLD SHUTDOWN HLAPM SEP 30. 2011 1 :12 PI.1 WHOLE SALE FUELS 2200 E BRUNI)AGE BAKERSFIELD CA 93304 SEP 20. 2011 t :21 PP1 112TEM STATI-IS REPORT Cr 5: PERIOPIC LINE FAIL WHOLE `SALE FUEL: 22D0 E flRUNDIE HAKERSF 1 ELI) CA 93304 SEP' 30, 20)1 1:24 PM SYSTEM STHTUS REPORT V 0 5:PERIODIC LINE FOIL SWRCB, January 2006 Spill Bucket Testing Report Form Thisform is intendedfor use by contractors performing annual testing of UST spill containment structures. The completedform and printoutsfrom tests (fapplicable), should be provided to thefacility owner /operatorfor submittal to the local regulatory agency. 1. FACILITY INFORMATION Facility Name: #1001 Wholesale Fuels I Date of Testing: 9/30/2011 Facility Address: 2200 East Brundage Lane , Bakersfield, CA 93307 Facility Contact: Omero Garcia I Phone: 661- 393 -7000 Date Local Agency Was Notified of Testing: 8/29/2011 Name of Local Agency Inspector (rfpresent during testing): Ester 2. TESTING CONTRACTOR INFORMATION Company Name: Confidence UST Services, Inc. Technician Conducting Test: Bradley Seykora Credentials': x CSLB Contractor x ICC Service Tech. SWRCB Tank Tester Other (Spec) License Number(s): CSLB #804904 ]CC # 8111231 3. SPILL BUCKET TESTING INFORMATION Test Method Used: x Hydrostatic Vacuum Other Test Equipment Used: Lake Test Equipment Resolution: 0.0625" Identify Spill Bucket (By Tank Number, Stored Product, etc. 1) T -1 2) T -2 3) T -3 4) T -4 Bucket Installation Type: x Direct Bury Contained in Sump x Direct Bury Contained in Sump x Direct Bury Contained in Sump x Direct Bury Contained in Sum Bucket Diameter: 12.00" 12.00" 12.00" 12.00" Bucket Depth: 14.25" 13.75" 13.75" 14.00" Wait time between applying vacuum /water and start oftest: 5 minutes 5 minutes 5 minutes 5 minutes Test Start Time (Tj): 9:30 A.M. 9:30 A.M. 9:30 A.M. 9:30 A.M. Initial Reading (Rj): 11.50" 11.25" 11.50" 11.75" Test End Time (TF): 10:30 A.M. 10:30 A.M. 10:30 A.M. 10:30 A.M. Final Reading (RF): 10.00" 11.25" 10.50" 11.25" Test Duration (TF — Tj): 10 min. 1 hour 10 min. 1 hour Change in Reading (RF - Rj): 1.50" 0.00" 1.00" 0.50" Pass /Fail Threshold or Criteria: 0.0625" 0.0625" 0.0625" 0.0625" Test Result. Pass © Fail Pass Fail Pass x Fail Pass O Fail Comments — (include information on repairs made prior to testing, and recommendedfollow -upforfailed tests) The Phil -Tite spill buckets on tank's 1 2 and 3 failed and need to be replaced. CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING hereby certify that all the information contained in this report is true, accurate, and in full compliance with legal requirements. Technician's Signature: Date: 9/30/2011 State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements may be more stringent. SWRCB, January 2006 Spill Bucket Testing Report Form This, form is intendedfor use by contractors performing annual testing ofUST spill containment structures. The completedform and printoutsfrom tests (if applicable), should be provided to thefacility owner /operatorfor submittal to the local regulatory agency. 1. FACILITY INFORMATION Facility Name: #1001 Wholesale Fuels I Date of Testing: 9/30/2011 Facility Address: 2200 East Brundage Lane, Bakersfield, CA 93307 Facility Contact: Omero Garcia Phone: 661- 393 -7000 Date Local Agency Was Notified of Testing: 8/29/2011 Name ofLocal Agency Inspector (rfpresent dewing testing): Ester 2. TESTING CONTRACTOR INFORMATION Company Name: Confidence UST Services, Inc. Technician Conducting Test: Bradley Seykora Credentials: ® CSLB Contractor ® ICC Service Tech. SWRCB Tank Tester Other (Specify) License Number(s): CSLB #804904 ICC # 8111231 3. SPILL BUCKET TESTING INFORMATION Test Method Used: ® Hydrostatic Vacuum Other Test Equipment Used: Lake Test Equipment Resolution: 0.0625" Identify Spill Bucket (By Tank Number, Stored Product, etc.) 1) T -5 2) T -6 3) 4) Bucket Installation Type: Direct Bury Contained in Sump Direct Bury Contained in Sump Direct Bury Contained in Sump Direct Bury Contained in Sum Bucket Diameter: 12.00" 12.00" Bucket Depth: 14.00" 14.25" Wait time between applying vacuum /water and start of test: 5 minutes 5 minutes Test Start Time (Ti): 9:30 A.M. 9:30 A.M. Initial Reading (Rj): 11.75" 12.00" Test End Time (TF): 10:30 A.M. 10:30 A.M. Final Reading (RF): 11.75" 12.00" Test Duration (TF — Ti): 1 hour 1 hour Change in Reading (RF- Rj): 0.00" 0.00" Pass /Fail Threshold or Criteria: 0.0625" 0.0625" Test Result: Pass Fail Pass Fail Pass Fail Pass Fail Comments — (include information on repairs made prior to testing, and recommendedfollow -upforfailed tests) CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING I hereby certify that all the information contained in this report is true, accurate, and in full compliance with legal requirements. Technician's Signature: Date: 9/30/2011 State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements may be more stringent. 40 1DF C, tt Tj CE5 + M4PLuMCU WIT" ODwimwc- Invoice No.: 27797 Repairs completed: Required Repairs, Still Pending: The fill spill buckets or tank's 1, 2 and 3 need to be replaced and retested, and there is a diesel leak from the turbine on tank 3 that needs to be fixed. Signature: Date: 9/30/2011 1001 Wholesale Fuels 2200 East Brundage Lane Bakersfield, CA 93380 -2277 TLS -350 Overfill Alarm Tank 2 UDC STP 2 O Tank 1 UDC L3 STP 2 O L3 L2 - UDC, tank's 4, 5, 6, 208 sensor L3 - UDC, tank's 1, 2, 3, 208 sensor 1 - Mag Probe 2 - WPLLD ESO OClear Diesel 10,000 gal. STP 2 O ODyed Diesel 10,000 gal. STP 2 O Clear Diesel 20,000 gal. STP 1,2 O STP Regular unleaded 20,000 1, 2 O Ogal. Dyed Diesel 20,000 gal. STP 1,2 FO Dyed Diesel 20,000 gal. STP 1 2 FO