Loading...
HomeMy WebLinkAbout1101 UNION AVENUE (2)Pre- Engineered Restaurant Fire Suppression Systems Report AAA QUALITY SE tl,12C. 5300 SO. UNION BAKEISMELD, CA 93307 -5426 601) 833 -5510 FAX 833 -5512 CU TOMER / y Name /d/ 0 Role Address ®' City State ZIPy Telephone b & 0 - 325_ 7 :7'l Store No. Owner or Manager DATE OF SERVICE TIME A.M. P.MI f%O i ANNUAL SEMI= ANNUAL RECHARGE INSTALLATION RENOVATION LOCATION OF SYSTE CYLINDERS UL 300 O S NOVE MANUFACTURER MODEL NUMBER WET DRY CHEMICAL U ® I 4 CY INDER SIZE MASTER CYLINDER SIZE SLAVE CYLINDER SIZE SLAVE 29. Replace systems covers FUSE LINKS 360' F. FUSE LINKS 450° F. FUSE LINKS 500° F. OTHER 31. Slave system operational FUEL SHUT -OFF ELECTRIC GAS SIZE V k_ L„/ SERIAL NUMBER LAST HYDRO TEST DATE LAST RECHARGE DATE MANUFACTURER'S MANUAL REFERENCE PAGE NUMBER: DRAWING NUMBER: DATE 1. All appliances properly covered w /correct nozzles 2. Duct and plenum covered w /correct nozzles 3. Check positioning of all nozzles. 4. System installed in accordance w /MFG UL listing 5. Hood /duct penetrations sealed w /weld or UL device 6. Check if seals.intact, evidence of tampering 7. If system has been discharged, report same 8. Pressure gauge in proper range (If gauged) 9. Check cartridge weight (If applicable) 10. Hydrostatic test date 11. 6 year maintenance date 12. Inspect cylinder and mount 13. Operate system from terminal link 14. Test for proper operation from remote 15. Check operation of micro switch 16. Check operation of gas valve 17. Clean nozzles 18. Proper nozzle covers in place 19. Check fuse links and clean COMMENTS: On this date, this pre- engineered fire s,p4ression system was inspected and operationally tested in accordance with the fire suppression system requirements oJNF WA F -17A, 96 and the manufacturer's manual with the results indicated above. X dr"" fv _ r4y. c-SERVICE ECHNICIAN PERMIT NO. 'DATE: TIME: AM PM -- _CUSTOM ER'S AUTHORIZED AGENT The above`Fvice technician certifies that the system was personally inspected and found conditions to=be as indicated on this report. AUTHORITY HAV! NG JURISDICTION 20. Replaced fuse links 21. Check travel of cable nuts /S -hooks 22. Piping & conduit securely bracketed 23. Proper separation between fryers & flame 24. Proper clearance -flame to filters 25. Exhaust fan in operating order 26. All filters in place 27. Fuel shut -off in on position T 28. Manual & remote set/seals in place 29. Replace systems covers 30. System operational & seals in place 31. Slave system operational 32. Clean cylinder & mount 33. Fan warning sign on hood 34. Personnel instructed in manual operation of system 35. Proper hand portable extinguishers 36. Portable extinguishers properly serviced 0 37. Service & Certification tag on system _ NOTE DISCREPANICES OR DEFICIENCIES BELOW On this date, this pre- engineered fire s,p4ression system was inspected and operationally tested in accordance with the fire suppression system requirements oJNF WA F -17A, 96 and the manufacturer's manual with the results indicated above. X dr"" fv _ r4y. c-SERVICE ECHNICIAN PERMIT NO. 'DATE: TIME: AM PM -- _CUSTOM ER'S AUTHORIZED AGENT The above`Fvice technician certifies that the system was personally inspected and found conditions to=be as indicated on this report. AUTHORITY HAV! NG JURISDICTION