Loading...
HomeMy WebLinkAbout1109 PACHECO ROAD (3)Range Hood Systems Report SERVICE COMPANY DATE OF 7V7_ TIME A.M. I P.M. AAA M ALITY SERV Ar -G, INC. ANNUAL SEMI- ANNUAL RECHARGE INSTALLATION RENOVATION 5800 SO. UNION A VLRCSFIIFLD, CA 93307 -5426 1) 833 -5510 FAX 833 -5512 4. System installed in accordance w /MFG UL listing 23. Proper separation between fryers & flame 5. LOCATION OF SYSTEM CYLINDERS r t ` r C, UL 300 xes No ANUFACTURER MODELrrNUMBER WET DRY CHEMICAL CYLINDER SIZE MASTER CYLINDER SIZE SLAVE CYLINDER SIZE SLAVE Ct 26. All filters in place -- FUSE LINKS 360° F. 3 FUSE LINKS 450° F. FUSE LINKS 500' F. OTHER C STOMER Name 66'eeK Prr r /IiC' `l /tlLtiG' Address FUEL SHUT -OFF ELECTRIC GAS SIZE l /'l z City =l! p State( ZIPS / J / I SERIAL NUMBER LAST HYDRO TEST DATE Os LAST RECHARGE DATE l J jI MANUFACTURER'S MANUAL REFERENCE Telephone 7/S / [ /7( /i yy Store No. Inspect cylinder and mount PAGE NUMBER: DRAWING NUMBER: DATE Owner or Manager 71/l. t_' V (- U y COOKING APPLIANCE LOCATIONS: LEFT TO RIGHT 1. All appliances properly covered w /correct nozzles 20. Replaced fuse links 2. Duct and plenum covered w /correct nozzles 21. Check travel of cable nuts /S -hooks 3. Check positioning of all nozzles. 22. Piping & conduit securely bracketed 4. System installed in accordance w /MFG UL listing 23. Proper separation between fryers & flame 5. Hood /duct penetrations sealed w /weld or UL device 24. Proper clearance -flame to filters 6. Check if seals intact, evidence of tampering i` 25. Exhaust fan in operating order 7. If system has been discharged, report same z 26. All filters in place -- 8. Pressure gauge in proper range (If gauged) 27. Fuel shut -off in on position 9. Check cartridge weight (If applicable) 28. Manual & remote set/seals in place - 10. Hydrostatic test date 29. Replace systems covers 11. 6 year maintenance date 30. System operational & seals in place 12. Inspect cylinder and mount 31. Slave system operational 13. Operate system from terminal link 32. Clean cylinder & mount 14. Test for proper operation from remote 33. Fan warning sign on hood 15. Check operation of micro switch 34. Personnel instructed in manual operation of system 16. Check operation of gas valve 35. Proper hand portable extinguishers 17. Clean nozzles i 36. Portable extinguishers properly serviced 18. Proper nozzle covers in place 37. Service & Certification tag on system 19. Check fuse links and clean i NOTE DISCREPANICES OR DEFICIENCIES BELOW -- r VCOMMENTS: F- E r On this date, this range hood fire suppression system was inspected and operationally tested in accordance with the fire suppression system` requirements of NFPA17 or 17A, 96 and the manufacturer's manual, with the results indicated above. SERVICE TECHNICIAN PERMIT NO. DATE: TIME: AM PM CUSTOMER'S AUTHORIZED AGENT The above service technician certifies that the system was personally inspected and found conditions to be as indicated on this report. AU4HOR[IT 7 HAVING dU6 I]S011 yl]OM