Loading...
HomeMy WebLinkAbout1419 BRUNDAGE LANE (2)WE Pre - Engineered Restaurant Fire Suppression Systems Report C ,k-i AAA QUALITY SERVICES, INC. 5800 SO. UNION BAKERSFIELD, CA 93307 -5426 661) 833 -5510 FAX 833 -5512 CUSTOMER Name v.c.S['S f\IC Address t ` { S u c` G G -f y City ) , State ZIP 9 33U'I Telephone 3Z7.. - oV 1 1 I 1 Store No. Owner or Manager DATE OF SERVICE TIME A.M. P.M. 22. Piping & conduit securely bracketed 23. Proper separation between fryers & flame I ANNUAL SEMI- ANNUAL RECHARGE INSTALLATION RENOVATION 27. Fuel shut -off in on position 28. Manual & remote set/seals in place LOCATION OF SYSTEM CYLINDERS UL 300 1 YES r_1 NO t, FDRYMANUFACTURERSMN8Rf*. WET CHEMICAL 34. Personnel instructed in manual operation of system 35. Proper hand portable extinguishers 36. Portable extinguishers properly serviced a 37. Service & Certification tag on system CYLINDER SIZE MASTER AL SIZE SLAVECAL CYLINDER SIZE SLAVEkINQER 2 0 FUSE LINKS 360° F. FUSE LINKS 450° F. FUSE LINKS 500° F. OTHER Cr FUEL SHUT -OFF ELECTRIC GAS SIZE Y SERIAL NUMBER LAST HYDRO TEST DATE LAST RECHARGE DATE MANUFACTURER'S MANUAL REFERENCE PAGE NUMBER: DRAWING NUMBER: DATE COOKING APPLIANCE LOCATIONS: LEFT TO RIGHT 21. Check travel of cable nuts /S -hooks s 22. Piping & conduit securely bracketed 23. Proper separation between fryers & flame 24. Proper clearance -flame to filters A 1. All appliances properly covered w /correct nozzles 2. Duct and plenum covered w /correct nozzles 3. Check positioning of all nozzles. 4. System installed in accordance w /MFG UL listing 5. Hood /duct penetrations sealed w /weld or UL device 6. Check if seals intact, evidence of tampering 7. If system has been discharged, report same 8. Pressure gauge in proper range (If gauged) 9. Check cartridge weight (If applicable) 10. Hydrostatic test date 11. 6 year maintenance date 12. Inspect cylinder and mount 13. Operate system from terminal link 14. Test for proper operation from remote 15. Check operation of micro switch 16. Check operation of gas valve 17. Clean nozzles 18. Proper nozzle covers in place 19. Check fuse links and clean COMMENTS: \ \R A\ C e 20. Replaced fuse links 21. Check travel of cable nuts /S -hooks s 22. Piping & conduit securely bracketed 23. Proper separation between fryers & flame 24. Proper clearance -flame to filters A 25. Exhaust fan in operating order s 26: All filters in place 27. Fuel shut -off in on position 28. Manual & remote set/seals in place 29. Replace systems covers 30. System operational & seals in place 31. Slave system operational t 32. Clean cylinder & mount 33. Fan warning sign on hood 34. Personnel instructed in manual operation of system 35. Proper hand portable extinguishers 36. Portable extinguishers properly serviced a 37. Service & Certification tag on system N TE DISCREPANICES OR DEFICIENCIES BELOW r On this date, this pre- engineered fire suppression system was inspected and operationally tested in accordance with the fire suppression system requirements of NFPA17 or 17A, 96 and the manufacturer's manual with the results indicated above. SERVICE TECHNICIAN PERMIT NO. , DATE: TIME: AM PM CUSTOMER'S AUTHORIZED AGENT The above service technician certifies that the system was personally inspected and found conditions to be as indicated on this report. AU7H00 WV aQVUB JMR20270M