HomeMy WebLinkAbout2900 BERKSHIRE (2)Pre - Engineered Restaurant Fire Suppression Systems Report
SERVICE COMPANY
a..
0. 1.
CA C
CUSTOMER
Name ! .A u. , +- , >, n S<
t
Address ' i! )0 r f.
City : r •. 1 ti State L ' A ZIP
Telephone : j, rl) ')3 2 - hd -Y 2 Store No.
Owner or Manager
DATE OF SERVICE TIME A.M. P.M.
1 -Eu Iz
21. Check travel of cable nuts /S -hooks
J
ANNUAL SEMI- NUAL RECHARGE INSTALLATION RENOVATION
LOCATION OF SYSTEM CYLINDERS UL 300
tV f. k ' Hoc-)A OYES NO
MANUFACTURER MODEL NUMBER WET DRY CHEMICAL
A ,v UZ_
27. Fuel shut -off in on position
9. Check cartridge weight (If applicable)
CYLINDER SIZE MASTER CYLINDER SIZE SLAVE CYLINDER SIZE SLAVE
29. Replace systems covers
11. 6 year maintenance date
FUSE LINKS 360° F. FUSE LINKS 450° F. FUSE LINKS 500° F OTHER
31. Slave system operational !
13. Operate system from terminal link 32. Clean cylinder & mount
FUEL SHUT -OFF ELECTRIC GAS SIZE
34. Personnel instructed in manual operation of system
16. Check operation of gas valve 35. Proper hand portable extinguishers i
17. Clean nozzles t/ 36. Portable extinguishers properly serviced
SERIAL NUMBER LAST HYDROTEST DATE LASTRECHARGE DATE
19. Check fuse links and clean r NOTE DISC OR DEFICIENCIES BELOW
MANUFACTURER'S MANUAL REFERENCE
PAGE NUMBER: DRAWING NUMBER: DATE
COOKING APPLIANCE LOCATIONS: LEFT TO RIGHT
20. Replaced fuse links
2. Duct and plenum covered w /correct nozzles 21. Check travel of cable nuts /S -hooks
J 1
22. Piping & conduit securely bracketed
4. System installed in accordance w /MFG UL listing
1. All appliances properly covered w /correct nozzles 20. Replaced fuse links
2. Duct and plenum covered w /correct nozzles 21. Check travel of cable nuts /S -hooks
3. Check positioning of all nozzles. 22. Piping & conduit securely bracketed
4. System installed in accordance w /MFG UL listing 23. Proper separation between fryers & flame >"
5. Hood /duct penetrations sealed w /weld or UL device 24. Proper clearance -flame to filters t
6. Check if seals intact, evidence of tampering 25. Exhaust fan in operating order
7. If system has been discharged, report same 26. All filters in place
8. Pressure gauge in proper range (If gauged) 27. Fuel shut -off in on position
9. Check cartridge weight (If applicable)
r
28. Manual & remote set/seals in place
10. Hydrostatic test date 29. Replace systems covers
11. 6 year maintenance date 30. System operational & seals in place
12. Inspect cylinder and mount 31. Slave system operational !
13. Operate system from terminal link 32. Clean cylinder & mount
14. Test for proper operation from remote 33. Fan warning sign on hood
15. Check operation of micro switch 34. Personnel instructed in manual operation of system
16. Check operation of gas valve 35. Proper hand portable extinguishers i
17. Clean nozzles t/ 36. Portable extinguishers properly serviced
18. Proper nozzle covers in place li' 37. Service & Certification tag on system -
19. Check fuse links and clean r NOTE DISC OR DEFICIENCIES BELOW
COMMENTS: U! c +Q
1REPANICES
r -' t .- C E_ t t AI
J / J
On this date, this pre- engineered fire suppression system was inspected and operationally tested in accordance with the fire
suppression system requirements of NFPA1.7 or 17A, 96 and the manufacturer's manual with the results indicated above;
X e 0 - / Z 1 J 1X_ fit.? % '.
SERVICE TECHNICIAN PERMIT NO. DATE: TIME: AM PM CUSTOMER'S AUTHORIZED AGENT
The above service technician certifies that the system was personally inspected and found conditions to be as indicated on this report.
QM NCQ)P%04V HAV9 MQ JURISDICTION