HomeMy WebLinkAbout2900 BERKSHIRE (2)Pre - Engineered Restaurant Fire Suppression Systems Report SERVICE COMPANY a.. 0. 1. CA C CUSTOMER Name ! .A u. , +- , >, n S< t Address ' i! )0 r f. City : r •. 1 ti State L ' A ZIP Telephone : j, rl) ')3 2 - hd -Y 2 Store No. Owner or Manager DATE OF SERVICE TIME A.M. P.M. 1 -Eu Iz 21. Check travel of cable nuts /S -hooks J ANNUAL SEMI- NUAL RECHARGE INSTALLATION RENOVATION LOCATION OF SYSTEM CYLINDERS UL 300 tV f. k ' Hoc-)A OYES NO MANUFACTURER MODEL NUMBER WET DRY CHEMICAL A ,v UZ_ 27. Fuel shut -off in on position 9. Check cartridge weight (If applicable) CYLINDER SIZE MASTER CYLINDER SIZE SLAVE CYLINDER SIZE SLAVE 29. Replace systems covers 11. 6 year maintenance date FUSE LINKS 360° F. FUSE LINKS 450° F. FUSE LINKS 500° F OTHER 31. Slave system operational ! 13. Operate system from terminal link 32. Clean cylinder & mount FUEL SHUT -OFF ELECTRIC GAS SIZE 34. Personnel instructed in manual operation of system 16. Check operation of gas valve 35. Proper hand portable extinguishers i 17. Clean nozzles t/ 36. Portable extinguishers properly serviced SERIAL NUMBER LAST HYDROTEST DATE LASTRECHARGE DATE 19. Check fuse links and clean r NOTE DISC OR DEFICIENCIES BELOW MANUFACTURER'S MANUAL REFERENCE PAGE NUMBER: DRAWING NUMBER: DATE COOKING APPLIANCE LOCATIONS: LEFT TO RIGHT 20. Replaced fuse links 2. Duct and plenum covered w /correct nozzles 21. Check travel of cable nuts /S -hooks J 1 22. Piping & conduit securely bracketed 4. System installed in accordance w /MFG UL listing 1. All appliances properly covered w /correct nozzles 20. Replaced fuse links 2. Duct and plenum covered w /correct nozzles 21. Check travel of cable nuts /S -hooks 3. Check positioning of all nozzles. 22. Piping & conduit securely bracketed 4. System installed in accordance w /MFG UL listing 23. Proper separation between fryers & flame >" 5. Hood /duct penetrations sealed w /weld or UL device 24. Proper clearance -flame to filters t 6. Check if seals intact, evidence of tampering 25. Exhaust fan in operating order 7. If system has been discharged, report same 26. All filters in place 8. Pressure gauge in proper range (If gauged) 27. Fuel shut -off in on position 9. Check cartridge weight (If applicable) r 28. Manual & remote set/seals in place 10. Hydrostatic test date 29. Replace systems covers 11. 6 year maintenance date 30. System operational & seals in place 12. Inspect cylinder and mount 31. Slave system operational ! 13. Operate system from terminal link 32. Clean cylinder & mount 14. Test for proper operation from remote 33. Fan warning sign on hood 15. Check operation of micro switch 34. Personnel instructed in manual operation of system 16. Check operation of gas valve 35. Proper hand portable extinguishers i 17. Clean nozzles t/ 36. Portable extinguishers properly serviced 18. Proper nozzle covers in place li' 37. Service & Certification tag on system - 19. Check fuse links and clean r NOTE DISC OR DEFICIENCIES BELOW COMMENTS: U! c +Q 1REPANICES r -' t .- C E_ t t AI J / J On this date, this pre- engineered fire suppression system was inspected and operationally tested in accordance with the fire suppression system requirements of NFPA1.7 or 17A, 96 and the manufacturer's manual with the results indicated above; X e 0 - / Z 1 J 1X_ fit.? % '. SERVICE TECHNICIAN PERMIT NO. DATE: TIME: AM PM CUSTOMER'S AUTHORIZED AGENT The above service technician certifies that the system was personally inspected and found conditions to be as indicated on this report. QM NCQ)P%04V HAV9 MQ JURISDICTION