Loading...
HomeMy WebLinkAbout1419 19TH STREETRange Hood Systems Report SERVICE COMPANY p i J. / f Cd , y y /"'f° 5_'V ddd///llllll AAA QUALITYU 3R6PM1'o77•gpWIImic. r DATE OF SERVICE f' / i' 0 TIME 11,L, A.M. P.M. X ANNUAL SEMI-ANNUAL RECHARGE INSTALLATION RENOVATION LOCATION OF SYSTEM CYLINDERS 8. Pressure gauge in proper range (If gauged) UL 300 5300 SO. UNION BAKERSFELD, CA 93307 -5426 j fN Gn ! i :r 1,' j YES RNO MANUFACTURE J MODEL NUMBER WET DRY CHEMICAL 667) 833 -5510 FAX 833 -5512 RCYINDERZIZEMASTER 1-! CYLINDER SIZE SLAVE CYLINDER SIZE SLAVE lD VVV 111 FUSE LINKS 360° F. FUSE LINKS 450° F 71NKS 500° F OTHER CUSTOMtR Name AI Ti ,Gv Address FUEL SHUT -OFF ELECTRIC GAS SIZE ` SERIAL NUMBER LAST HYDROTEST DATE LAST RECHARGE DATE City / /I 1 Lf State ZIP v. MANUFACTURER'S MANUAL REFERENCE Telephone Store No. PAGE NUMBER: DRAWING NUMBER: DATE Owner or Manager COOKING APPLIANCE LOCATIONS: LEFT TO RIGHT 1. All appliances properly covered w /correct nozzles 2. Duct and plenum covered w /correct nozzles a 3. Check positioning of all nozzles. 4. System installed in accordance w /MFG UL listing 5. Hood /duct penetrations sealed w /weld or UL device I 6. Check if seals intact,, evidence of tampering 7. If system has been discharged, report same il- 8. Pressure gauge in proper range (If gauged) I 9. Check cartridge weight (If applicable) 10. Hydrostatic test date 11 6 year maintenance date 12. Inspect cylinder and mount a 1`3. Operate system from terminal link 14. Test for proper operation from remote 15. Check operation of micro switch 16. Check operation of gas valve 17. Clean nozzles il- 18. Proper nozzle covers in place I 19. Check fuse links and clean 4 1 f , Ih UL5 CCOMMENTS: S J 20. Replaced fuse links 21. Check travel of cable nuts /S -hooks 22. Piping & conduit securely bracketed 23. Proper separation between fryers & flame 24. Proper clearance -flame to filters 25. Exhaust fan in operating order " 26. All filters in place 27. Fuel shut -off in on position 28. Manual & remote set/seals in place 29. Replace systems covers 30. System operational & seals in place 31. Slave system operational 32. Clean cylinder & mount 33. Fan warning sign on hood 34. Personnel instructed in manual operation of system 35. Proper hand portable extinguishers 36. Portable extinguishers properly serviced 37. Service & Certification tag on system NOTE DISCREPANICES OR DEFICIENCIES BELOW I I On this date, this range hood fire suppression system was inspected and operationally tested in accordance with the fire suppression system requirements of NFPA17 or 17A, 96 and the manufacturer's manual, with the results indicated above. X SERVICE TECHNICIANNICIAN PERMIT NO. DATE: TIME: AM PM CUSTOMER'S AUTHORIZED AGENT above service technician certifies that the system was personally inspected and found conditions to be as indicated on this report.