Loading...
HomeMy WebLinkAbout1520 20TH STREET (14)J .-'9 Spill Bucket Testing Report Form Thisform is intendedfor use by contractors performing annual testing of UST spill containment structures. The completed fawn and printouts from tests (ifapplicable), should be provided to thefacility owner /operatorforsubmittal to the local regulatory agency. FACILITY INFORMATION Facility ID: CAK010 Facility Name: AT &T Corporation Date of Testing: 5/18/2012 Facility Address: 1520 20TH ST, BAKERSFI ELD, CA 93301 Facility Contact: Grant Armstrong Phone: 661- 327 -6903 Date Local Agency Was Notified of Testing: 5/9/2012 Name ofLocal Agency Inspector (ifpresent during testing): Ernest Medina TESTING CONTRACTOR INFORMATION Company Name: TAIT Environmental Services, Inc. Technician Conducting Test: Stephen Graham Credential I : r CSLB Contractor ICC Service Tech. SWRCB Tank Tester r Other (Specify) License number(s): A B ASB C -10 HAZ License Number 588098 : 5240926 SPILL BUCKET TESTING INFORMATION TestMethod Used: Hydrostatic r Vacuum r Other Test Equipment Used: Marker and tape measure Equipment Resolution: 1/16" Identify Spill Bucket (By Tank Number, Stored Product,etc. ) 1 CAKOl0U001 Bucket Installation Type: f— Direct Bury F Contained in Sump r On top of AST F Direct Bury F Contained in Sump r On top of AST r Direct Bury r Contained in Sump r On top of AST r Direct Bury f— Contained in Sump r On top of AST Bucket Diameter: 12.5" Bucket Depth: 181, Wait time between applying vacuum /water and start of test: 15 minutes Test Start Time (Tl): 10:00 am Initial Reading (RI): 15.0" Test End Time (TF): 11:00 am Final Reading (RF): 15.0" Test Duration (TF —Tl): 1 hour Change in Reading (RF -Rl): 0" Pass /Fail Threshold or Criteria: 0.. Test Result: F Pass r Fail r Pass r Fail r Pass r— Fail r Pass r Fail Comments — (include information on repairs made prior to testing, and recommendedfollow -up for failed tests) All water returned to Tait shop. CERTIFICATION OFTECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING hereby certify that all the information contained in this report is true, accurate, and in full compliance with legal requirements. Technician's Signature: Date: 5/18/2012 d TAP T c,sinc ,o me cnnuta .t p:714'S60i8222 ww.toit _0-r. May 22, 2012 VIA FED EX: 7984 2348 4986 Bakersfield Fire Department 2101 H Street Bakersfield CA 93301 Re: Spill Bucket Testing AT &T Corporation 1520 20th STREET, BAKERSFIELD, CA GEOPAR: CAK010 To Whom it May Concern: 2.13! 5 Dupont fkn -e. Anahonn, CA 9:,806 Enclosed are the results for the following tests completed on May 18, 2012: Spill Bucket Testing Report Form Please do not hesitate to call me if you have any questions. ViheWwL. l rs, M Denison Program Manager CA cN 586098 , A2 1,C,- 095984 r NV I C 0049666 TX uca CR0000041