HomeMy WebLinkAbout1705 17TH STREETPre = Engineered Restaurant Fire Suppression Systerms Report
4?"- /o 7,5;71 /-/
AM QUALITY SERVICES9INC.
5800 SO. UNION
3AKERSFIELD, CA 93307 -5426
8r,l) 533 -5510 FAX 83,3 -5512
Name z± /:I ' i'
Address
City StateC42- ZIP
Telephone 4741/ R Store No.
Owner or Manager Z-2- Z_ ilJ ,'
COOKING APPLIANCE LOCATIONS: LEFT TO RIGHT
DATE OF SE VICE TIME A.M. P.M.
21. Check travel of cable nuts /S -hooks
3. Check positioning of all nozzles. 22. Piping & conduit securely bracketed
ANNUAL SEMI - ANNUAL I RECHARGE INSTALLATION RENOVATION
LOCATION OF SYSTEM CYLINDERS ULUL 300
a Iv /_ e- AYES C] NO
MANUFACTURER MODEL NUMBER WET DRY CHEMICAL
8. es ure gauge in proper range (If gauged) 27. Fuel shut -off in on position
9. peck cartridge weight (If applicable)
CYLINDER SIZE MASTER CYLINDER SIZE SLAVE CYLINDER SIZE SLAVE
29. Replace systems covers
11. 6 yea,maintenance date
FUSE LINKS 360° F. FUSE LINKS 450° F. FUSE LINKS 500° F. OTHER
9P 171
13. Operate\system from terminal link 32. Clean cylinder & mount
FUEL SHUT -OFF ELECTRIC GAS SIZE
SERIAL NUMBER LAST HYDRO TEST DATE T LAST RECHARGE DATE
35. Proper hand portable extinguishers
D -5
17. Clean nozzles
MANUFACTURER'S MANUAL REFERENCE
PAGE NUMBER: DRAWING NUMBER: DATE
1. All appliances properly covered w /correct nozzles 20. Replaced fuse links
2. Duct and plenum covered w /correct nozzles 21. Check travel of cable nuts /S -hooks
3. Check positioning of all nozzles. 22. Piping & conduit securely bracketed
4. System installed in accordance w /MFG UL listing 23. Proper separation between fryers & flame
5 Hood /duct penetrations sealed w /weld or UL device 24. Proper clearance -flame to filters
6 Check if seals intact, evidence of tampering 25. Exhaust fan in operating order
7 If system has been discharged, report same 26. All filters in place
8. es ure gauge in proper range (If gauged) 27. Fuel shut -off in on position
9. peck cartridge weight (If applicable) 28. Manual & remote set/seals in place
10.- Hydrostatic test date 29. Replace systems covers
11. 6 yea,maintenance date 30. System operational & seals in place
12. Inspect cylinder and mount 31. Slave system operational
13. Operate\system from terminal link 32. Clean cylinder & mount
14. Test for proper operation from remote 33. Fan warning sign on hood
15. Check operation of micro switch 34. Personnel instructed in manual operation of system
16. Check oper ion of gas valve 35. Proper hand portable extinguishers
17. Clean nozzles 36. Portable extinguishers properly serviced
18. Proper nozzle covers in place 37. Service & Certification tag on system
19. Check fuse links and clean NOTE DISCREPANICES OR DEFICIENCIES BELOW
COMMENTS: 45 Elz 144/ 444a n ; -44 7' 4-7.4426_-
On this date, this pre- engineered fire suppression system was inspected and operationally tested in accordance with the fire
suppression system requirements of NFPA17 or 17A, 96 and the manufacturer's manual with the results indicated above.
19 "ea `I- I / / /' /1/ V --
SERVICE TEOHNICIAN' PERMIT NO. DATE: TIME: AM PM CUST -MER' 3 AUTHORIZED AGENT
The above service technician certifies that the system was personally inspected and found conditions to be as indicated on this report.
uwomvv C;IQN/ r. JURISDICTION
Pre"Engineered Restaurant Fire Suppression Systems Report
AM ° (2UALM SERVICES, INC.
5800 SO. UNION
BAKERSFIELD, CA 93307 -5426
661) 633 -5510 FAX 8.33-!5512
Name-
Address / 745: 772
City State ( ,, ZIP 9;1 ;7e
Telephone 9/ ' Store No.
Owner or Manager grlG /e;1T
COOKING APPLIANCE LOCATIONS: LEFT TO RIGHT
DATE OF S5RVICE TIME A.M. P.M.
2. Duct and plenum covered w /correct nozzles 21. Check travel of cable nuts /S -hooks
3. Check positioning of all nozzles. 22. Piping & conduit securely bracketed
ANNUAL SEMI - ANNUAL RECHARGE INSTALLATION RENOVATION
LOCATION OF SYSTEM CYLINDERS UL 300
c// G Gz: YES E] NO
MANUFACTURER MODEL NUMBER WET DRY CHEMICAL
X l e:7 e -
11. 6 year maintenance date 30. System operational & seals in place
12. Inspect cylinder and mount 31. Slave system operational
13. Operate system from terminal link 32. Clean cylinder & mount
CYLINDER SIZE MASTER CYLINDER SIZE SLAVE CYLINDER SIZE SLAVE
GAG
FUSE LINKS 360° F. FUSE LINKS 450° F. FUSE LINKS 500° F OTHER
Ii19. Check fuse links and clean NOTE DISCREPANICES OR DEFICIENCIES BELOW
FUEL SHUT -OFF ELECTRIC GAS SIZE
Z
SERIAL NUMBER LAST HYDROTEST DATE LASTRECHARGE DATE
MANUFACTURER'S MANUAL REFERENCE
PAGE NUMBER: DRAWING NUMBER: DATE
COMMENTS: -4/
Oh this date, this pre- engineered fire suppression system was inspected and operationally tested in accordance with the fire
suppression system requirements of NFPA17 or 17A, 96 -and the manufacturer's manual with the results indicated; above.
X
SERVICE TECHNIC A PERMIT NO. DATE: TIME: AM PM IATO ER'S AUTHORIZED AGENT
The above service technician certifies that the system was personally inspected and found conditions to be as indicated on'tithis report.
AUTHORITY HAVING JURISDICTION
1. All appliances properly covered w /correct nozzles 20. Replaced fuse links
2. Duct and plenum covered w /correct nozzles 21. Check travel of cable nuts /S -hooks
3. Check positioning of all nozzles. 22. Piping & conduit securely bracketed
4. System installed in accordance w /MFG UL listing 23. Proper separation between fryers & flame
5. Hood /duct penetrations sealed w /weld or UL device 24. Proper clearance -flame to filters
6. Check if seals intact, evidence of tampering 25. Exhaust fan in operating order
7. If system has been discharged, report same :Iiz 26. All filters in place
8. Pressure gauge in proper range (if gauged) 27. Fuel shut -off in on position
9. Check cartridge weight (If applicable) 7Z7 28. Manual & remote set/seals in place
10. Hydrostatic test date 29. Replace systems covers
11. 6 year maintenance date 30. System operational & seals in place
12. Inspect cylinder and mount 31. Slave system operational
13. Operate system from terminal link 32. Clean cylinder & mount
14. Test for proper operation from remote 33. Fan warning sign on hood
15. Check operation of micro switch 34. Personnel instructed in manual operation of system
16. Check operation of gas valve 35. Proper hand portable extinguishers
17. Clean nozzles 36. Portable extinguishers properly serviced
18. Proper nozzle covers in place 37. Service & Certification tag on system
Ii19. Check fuse links and clean NOTE DISCREPANICES OR DEFICIENCIES BELOW
COMMENTS: -4/
Oh this date, this pre- engineered fire suppression system was inspected and operationally tested in accordance with the fire
suppression system requirements of NFPA17 or 17A, 96 -and the manufacturer's manual with the results indicated; above.
X
SERVICE TECHNIC A PERMIT NO. DATE: TIME: AM PM IATO ER'S AUTHORIZED AGENT
The above service technician certifies that the system was personally inspected and found conditions to be as indicated on'tithis report.
AUTHORITY HAVING JURISDICTION