HomeMy WebLinkAboutFIRE SUPPRESSION SYS 11/18/2011Pre - Engineered Restaurant Fire Suppression Systems Report SERVICE k11,A CU"MTV S'_7rVa1'7; 0I, UPCf. 5300 CO. UN ;3N DAK°'TIZIIELD, CA 93'c'07 -0,425 A) 833 -5510 FAX 833 -5512 C < CUSTOMER Name &.f7 Address t f ",-t Z2 City State ZIP Telephone (/ - Store No. Owner or Manager COOKING APPLIANCF LOCATIONS- LEFT TO RIGHT DATE OF SERVICE TIME A.M P.M. ANNUAL SEMI- NNUAL I RECHARGE INSTALLATION RENOVATION LOCATION OF SYSTEM CYLINDERS 300 1U UL VES NO AN F C MODEL NU B R WET DRY CHEMICAL gURER 23. Proper separation between fryers & flame 5. Hood /duct penetrations sealed w /weld or UL device 24. Proper clearance -flame to filters 6. Check if seals intact, evidence of tampering CYLIN ER SIZE ASTER CYLINDER SIZE SLAVE CYLINDER SIZE SLAVE FUSELINKS 360* F. FUSE LINKS 450° F. FUSE LINKS 500° F. OTHER FUEL SHUT -OFF ELECTRIC GAS/ SIZE 9. Check cartridge weight (If applicable) G 28. Manual & remote set/seals in place i SERIAL NUMBER LAST HYDRO TEST DATE LAST RECHARGE DATE 11. 6 year maintenance date MANUFACTURER'S MANUAL REFERENCE PAGE NUMBER: DRAWING NUMBER: DATE 6I ` yJ Q uv n . J) -P r ) t N , 'I ci tPv t 01 yi P 20. Replaced fuse links SERVICE TECHNICIAN' v PERMIT NO. 10T TIME: AM PM C RIZED AGENT The above service technician certifies that the system was personally inspected and found conditions to be as indicated on this report. AUTHORITY HAVING JURISDICTION 1. All appliances properly covered w /correct nozzles 20. Replaced fuse links 2. Duct and plenum covered w /correct nozzles Z 21. Check travel of cable nuts /S -hooks 3. Check positioning of all nozzles. 22. Piping & conduit securely bracketed 4. System installed in accordance w /MFG UL listing 23. Proper separation between fryers & flame 5. Hood /duct penetrations sealed w /weld or UL device 24. Proper clearance -flame to filters 6. Check if seals intact, evidence of tampering 25. Exhaust fan in operating order 7. If system has been discharged, report same 26. All filters in place 8. Pressure gauge in proper range (If gauged) 27. Fuel shut -off in on position 9. Check cartridge weight (If applicable) G 28. Manual & remote set/seals in place i 10. Hydrostatic test date 29. Replace systems covers 11. 6 year maintenance date 30. System operational & seals in place 12. Inspect cylinder and mount 31. Slave system operational 13. Operate system from terminal link 32. Clean cylinder & mount 14. Test for proper operation from remote i 33. Fan warning sign on hood 15. Check operation of micro switch 34. Personnel instructed in manual operation of system 16. Check operation of gas valve 35. Proper hand portable extinguishers 17. Clean nozzles 36. Portable extinguishers properly serviced 18. Proper nozzle covers in place 37. Service & Certification tag on system 19. Check fuse links and clean NOTE DISCREPANICES OR DEFICIENCIES BELOW COMMENTS: On this date, this pre- engineered fire suppression system was inspected and operationally tested in accordance with the fire suppression system requirements of NFPA17 or 17A, 96 and the manufacturer's manual with the results indicated above. SERVICE TECHNICIAN' v PERMIT NO. 10T TIME: AM PM C RIZED AGENT The above service technician certifies that the system was personally inspected and found conditions to be as indicated on this report. AUTHORITY HAVING JURISDICTION ri`' Yf.l r