Loading...
HomeMy WebLinkAbout800 FAIRVIEW ROAD (2)Pre - Engineered Restaurant Fire Suppression Systems Report pp n ,ry ner,pp n 27h, rn a,7 p.q r'ti..vti1 '.:. mil' =J ^^ m++:.c{. J ov_.y Cw 4s. 11`10 Cio..UppN:1_0N 4C;,A) €;33 -5513 FAX 333 -5512 Name Address ( Ji. iI City P P 1 State, ZIP -2 + \ Telephone 2 7, Store No. Owner or Manager DATE OF SERVICE TIME A.M. Pi 2. Duct and plenum covered w /correct nozzles 411 I ANNUAL SEMI- ANNUAL RECHARGE INSTALLATION RENOVATION v T 5. Hood /duct penetrations sealed w /weld or UL device T LOCATION OF SYSTEM CYLINDERS UL 300 C ! ( r5/ JYES F,1AOIL ` MAN FACTUR MODEL NUMBER WET DRY CHEMICAL 8. Pressure gauge in proper range (If gauged) T 27. Fuel shut -off in on position CYLINDER SIZE MASTER CYLINDER SIZE SLAVE CYLINDER SIZE SLAVE Z L ( C' 10. Hydrostatic test date l FUS LINKS 360° F. FUSE LINKS 450° F. FUSE LINKS 500° F. OTHER 30. System operational & seals in place 12. Inspect cylinder and mount FUEL SHOT -OFF ELECTRIC GAS SIZE 32. Clean cylinder & mounts 14. Test for proper operation from remote G 33. Fan warning sign on hood 15. Check operation of micro switch SERIAL NUMBER LAST HYDROTEST DATE LAST RECHARGE DATE MANUFACTURER'S MANUAL REFERENCE PAGE NUMBER: DRAWING NUMBER: DATE COOKING APPLIANCE LOCATIONS: LEFT TO RIGHT r1 y'1 r 2. Duct and plenum covered w /correct nozzles 411 3. Check positioning of all nozzles. 1. All appliances properlycovered w /correct nozzles 20. Replaced fuse links 2. Duct and plenum covered w /correct nozzles 21. Check travel of cable nuts /S -hooks 3. Check positioning of all nozzles. 22. Piping & conduit securely bracketed T/ 4. System installed in accordance w /MFG UL listing 23. Proper separation between fryers & flame T 5. Hood /duct penetrations sealed w /weld or UL device T 24. Proper clearance -flame to filters 6. Check if seals intact, evidence of tampering 25. Exhaust fan in operating order 7. If system has been discharged, report same 26. All filters in place 8. Pressure gauge in proper range (If gauged) T 27. Fuel shut -off in on position 9. Check cartridge weight (If applicable) 28. Manual & remote set/seals in place 10. Hydrostatic test date l 29. Replace systems covers 11. 6 year maintenance date 30. System operational & seals in place 12. Inspect cylinder and mount 31. Slave system operational LIi 13. Operate system from terminal link 32. Clean cylinder & mounts 14. Test for proper operation from remote G 33. Fan warning sign on hood 15. Check operation of micro switch 34. Personnel instructed in manual operation of system LX 16. Check operation of gas valve 35. Proper hand portable extinguishers 17. Clean nozzles 36. Portable extinguishers properly serviced r 18. Proper nozzle covers in place 37. Service & Certification tag on system y 19. Check fuse links and clean NOTE DISCREPANICES OR DEFICIENCIES BELOW COMMENTS: On this date, this pre- engineered fire suppression system was inspected and operationally tested in accordance with the fire suppression system requirements of NFPA17 or 17A, 96 and the manufacturer's manual with the results indicated above. X J'vIC` ,/,, NV I0- 25 -111 2: y, SERVICE TECHNICIAN PERMIT NO. DATE: TIME: AM PM CU$TUMER'S AUTHORIZED AGENT The above service technician certifies that the system was personally inspected and found conditions to be as indicated on this report. AUTHORITY HAVING JURISDICTION