Loading...
HomeMy WebLinkAbout800 FAIRFVIEW ROADPre - Engineered Restaurant Fire Suppression Systems Repaint COMPANY AAA QUALITY SERVICES, INC. 5800 SO. UNION BAKERSFIELD, CA 93307 -5426 661) 833 -5510 FAX 833 -5512 tom', " CUSTOMER Name _('-'Cr / /C fir'_ h Address Te:: lQ - r e 1/I P &L - y City I !a /< P y P /( State -(/4 ZIP ? Telephone Store No. Owner or Manager"_;, / iP/JC Ca COOKING APPLIANCE LOCATIONS: LEFT TO RIGHT b .h "/y v" (I -y- '/Jr) e lit h) Vr DATE OF SERVICE TIME A.M. P.M. 1. All appliances properly covered w /correct nozzles I ANNUAL SEMI - ANNUAL RECHARGE INSTALLATION RENOVATION T_ 3. Check positioning of all nozzles. 22. Piping & conduit securely bracketed LOCATION OF SYSTEM CYLINDERS UL 300 YES NOViv,C / i. MANUFACTURER MODEL NUMBER WET DRY CHEMICAL 25. Exhaust fan in operating order d 2 7. If system has been discharged, report same n CYLINDER SIZE MASTER CYLINDER SIZE SLAVE CYLINDER SIZE SLAVE z 27. Fuel shut -off in on position C FCKE LINKS 360° F. FUSE LINKS 450° F. FUSE LINKS 500° F. OTHER 10- Hydrostatic test date 29. Replace systems covers FUEL 9AUT -OFF ELECTRIC GAS SIZE L11 It SERIAL NUMBER LAST HYDRO TEST DATE LAST CHARGE DATE 14. Test for proper operation from remote MANUFACTURER'S MANUAL REFERENCE PAGE NUMBER: DRAWING NUMBER: DATE X / f ,o'1/,i/ Z -(_ % / I Z`" I I " ,'L lll_f -r %,l /j%li s_°r SERVICE TECHNICIAN PERMIT NO. ATE: TIME: AM PM - CUSTOMER'S AUTHORIZED AGENT The above service technician certifies that the system was personally inspected and found conditions to be as indicated on this report. I QMMMU NAV ma JUR20=0M 1. All appliances properly covered w /correct nozzles 20. Replaced fuse links C 2. Duct and plenum covered w /correct nozzles 21. Check travel of cable nuts /S -hooks T_ 3. Check positioning of all nozzles. 22. Piping & conduit securely bracketed 4. System installed in accordance w /MFG UL listing 23. Proper separation between fryers & flame 5. Hood /duct penetrations sealed w /weld or UL device 24. Proper clearance -flame to filters 6. Check if seals intact, evidence of tamperingI 25. Exhaust fan in operating order 7. If system has been discharged, report same n 26. All filters in place 8. Pressure gauge in proper range (If gauged) z 27. Fuel shut -off in on position 9. Check cartridge weight (If applicable) 28. Manual & remote set/seals in place G 10- Hydrostatic test date 29. Replace systems covers 11.. 6 year maintenance date 30. System operational & seals in place 12. Inspect cylinder and mount 31. Slave system operational f 13. Operate system from terminal link 32. Clean cylinder & mount 14. Test for proper operation from remote 33. Fan warning sign on hood 15. Check operation of micro switch 34. Personnel instructed in manual operation of system 7` 16. Check operation of gas valve 35. Proper hand portable extinguishers 17. Clean nozzles fir 36. Portable extinguishers properly serviced 18. Proper nozzle covers in place 37. Service & Certification tag on system 19. Check fuse links and clean i / NOTE DISCREPANICES OR DEFICIENCIES BELOW f COMMENTS: t C'r C f . On this date, this pre- engineered fire suppression system was inspected and operationally tested in accordance with the fire suppression system requirements of NFPA17 or 17A, 96 and the manufacturer's manual with the results indicated above. X / f ,o'1/,i/ Z -(_ % / I Z`" I I " ,'L lll_f -r %,l /j%li s_°r SERVICE TECHNICIAN PERMIT NO. ATE: TIME: AM PM - CUSTOMER'S AUTHORIZED AGENT The above service technician certifies that the system was personally inspected and found conditions to be as indicated on this report. I QMMMU NAV ma JUR20=0M