HomeMy WebLinkAboutINSP TEST 12/23/2011f 1 90VII., 7- OP_L` 25 -78 INSPECTION, TESTING, AND MAINTENANCE, OF WATER -BASED FIRE PROTECTION SYSTEMS r inspection, Testing, and Maintenance Cover Sheet NFPA 25 as amended by CCR, Title 19 Property Information: Name: . yBi/ a k M1.1 ]-A4tWOccupancy /Use: Meal. c1. _I or- CA4j' Address: Construction Type: City: a— _';( c( No. Stories: ZIP: 4 3 3 3 nnP` Year Constructed: Contact: iM : c,% l Pa r, y C Q N C O rh M tr c.,{ j Telephone: Contractor Information: n Number of System Risers Name: /T'IT 1f %cr Qr(j I Copy sent to: Address: Jr'8'Ot3 c'[^.l`l?'d 17`p -t: /Owner Date City: _UU I''4 1 Q(,c erj"re AHJ Date State: _ ( f7 /Contractor Date Telephone: ry 6V1— T33— 6510 NOTES: 1) For specific inspection, testing, andCALicense# _ maintenance requirements and information, j see NFPA 25, 2002 Edition as amended by California Code of Regulations, Title 19, §901 Performed by: to §906. f Qi Print) 2) Inspection Items may be performed by the Owner In accordance with California Code of Note: Contractor information may be pre - printed Regulations Title 19 904.1 a Forms included with this report NFPA 25 Chapter Number of Forms N/A FAIL* PASS Automatic Sprinkler System 5 Standpipe and Hose Systems 6 Private Water Supply System 7 Fire Pump 8 Water Storage Tank 9 Water Spray System 10 Foam Water Sprinkler System 11 See "Deficiencies and Comments" section at end of each respective form I State Fire Marshal AES 1 March 21, 20 Inspection, Testing, and Maintenance Fire Sprinkler System Page 1 of 4 NFPA 25 Chapter 5 as amended by CCR, Title 19 Date of Inspection, Testing, Maintenance: System Riser ID: Property Information: Initial Static Pressure: (psi) Name: (3 dQiWo..K Meal', c_a. P Ic-#-ZG. Address: 9 336 Slo cX da, ls, -- IA - w j Type 9f System: `o` A;rt1 l7 Wet Pipe N% Dry Pipe Preaction u l M = Maintenance A -O = After Operation Deluge MP. L q City: S.K•er s ; e 1 Main Drain Test Results: Abbreviation Key: I = Inspection Initial Static Pressure: (psi) T = Test Residual Pressure: u (psi) M = Maintenance A -O = After Operation Oy MI =Per Manufacturer's Instructions Restored Static Pressure: (psi) Item Activity Frequency Description NFPA 25 Fail N/A PassReference 1.1 1 Daily Preaction /Deluge Valves — Enclosure 12.4.3.1Weeklytemperature 1.2 1 Daily Weekly Dry Pipe Valves — Enclosure temperature 12.4.4.1.1 1.3 1 Quarterly Gauges (Dry, Preaction, Deluge Systems) 5.2.4.2 5.2.4.3 1.4 1 Quarterly Control Valves 12.3.2.1 1- 01 1.5 1 Quarterly Alarm Devices 5.2.6 1.6 1 Quarterly Gauges (Wet Pipe Systems) 5.2.4.1 1.7 1 Quarterly Hydraulic nameplate 5.2.7 1.8 1 Quarterly Sprinklers 5.2.1 1.9 1 Quarterly Spare Sprinklers 5.2.1.3 1.10 1 Quarterly Fire Department Connections 12.7.1 1.11 1 Quarterly Alarm Valves — Exterior Inspection 12.4.1.1 1.12 1 Quarterly Preaction /Deluge Valves — Exterior Inspection 12.4.3.1.6 1.13 1 Quarterly Pressure Reducing Valves 12.5.1.1 1.14 1 Quarterly Dry Pipe Valves — Exterior Inspection 12.4.4.1.4 1.15 1 Quarterly Backflow Preventers 12.6.1 1.16 1 Annually Pipe and Fittings 5.2.2 1.17 1 Annually Buildings 5.2.5 State Fire Marshal AES 2 June 17, 2008 Inspection, Testing, and Maintenance Fire Sprinkler System Page 2 of 4 NFPA 25 Chapter 5 as amended by CCR Title 19 Date of Inspection, Testing, Maintenance: I System Riser ID: Property Information: NFPAn aRefere Name: R;r G!w al Y, dv c.a., 17 oN,o, Address: 9330 $oGiGd c„1 -4 Type o ystem: ° ,V qA±c %I1 Wet Pipe Dry Pipe PreactionJDeluge 1 E MPQ City: Saxers e.1 d 5.2.3 Item Activity Frequency Description NFPAn aRefere Fail N/A Pass 1.18 1 Annually Hangers 5.2.3 1.19 1 Annually Seismic Braces 5.2.3 1.20 1 5 Years Hangers (Accessible concealed spaces) 5.2.3.3 1.21 1 5 Years Seismic Braces (Accessible concealed spaces) 5.2.3.3 1.22 I 5 Years Pipe and Fittings (Accessible concealed spaces) 5.2.2.3 1.23 1 5 Years Sprinklers (Accessible concealed spaces) 5.2.1.1.4 1.24 1 5 Years Alarm Valves — Interior Inspection 12.4.1.2 1.25 1 5 Years Alarm Valves - Strainers, filters, orifices 12.4.1.2 1.26 1 5 Years Check Valves — Interior Inspection 12.4.2.1 1.27 1 5 Years Preaction /Deluge Valves — Interior Inspection 12.4.3.1.7 1.28 1 5 Years Preaction /Deluge Valves - Strainers, filters, orifices 12.4.3.1.8 1.29 1 5 Years Dry Pipe Valves — Interior Inspection 12.4.4.1.5 1.30 1 5 Years Dry Pipe Valves - Strainers, filters, orifices 12.4.4.1.6 2.1 T Annually Alarm Devices (90 Sec) 5.3.3 12.2.7 2.2 T Annually Main Drain Test (Enter.data on Page 1) 12.2.6 12.2.6.1 12.3.3.4 2.3 T Annually Antifreeze Test 5.3.4 2.4 T Annually Control Valve - Position 12.3.3.1 2.5 T Annually Control Valve — Operation 12.3.3.1 2.6 T Annually Supervisory ' 12.3.3.5 2.7 T Annually Preaction Valve — Priming Water 12.4.3.2.1 2.8 T Annually Preaction Valve — Low Air Pressure Alarm 12.4.3.2.10 State Fire Marshal AES 2 June 17, 2008 Inspection, Testing, and Maintenance Fire Sprinkler System Page 3 of 4 NFPA 25, Chapter 5 as amended by CCR Title 19 Date of Inspection, Testing, Maintenance: \I - Z 03.4 11 System Riser ID: Property Information: NFPA 25 Reference Name: , VVStj -N1 k Medl IC41A 'P1rOVIAP -. Type of ystem: f CA4; 11MetPipe Address: q'33 -3 ko so a.A Q, VA ` Dry Pipe rPreaction T Deluge 9. i SAPLF /REMPP; City: Qo.hCE;!'S rrie. d 12.4.3.2.2 Item Activity Frequency Description NFPA 25 Reference Fail N/A Pass 2.9 T Annually Preaction Valve — Full Flow Trip Test 12.4.3.2.2 2.10 T Annually Dry Pipe Valve — Priming Water 12.4.4.2.1 2.11 T Annually Dry Pipe Valve — Low Air Pressure Alarm 12.4.4.2.6 2.12 T Annually Dry Pipe Valve — Quick - Opening Device 12.4.4.2.4 2.13 T Annually Dry Pipe Valve — Trip Test 12.4.4.2.2 2.14 T Annually Backflow Preventer Assemblies 12.6.2 2.15 T 3 Years Dry Pipe Valve — Full Flow Trip Test 12.4.4.2.2.2 2.16 T 5 Years Gauges 5.3.2 2.17 T 5 Years Pressure Reducing Valve 12.5.1.2 2.18 T 5 Years Fire Department Connection Backflush 12.7.4 2.19 T 5 Years Sprinklers — Extra High Temperature 5.3.1.1.1.3 2.20 T 5 Years Sprinklers — Corrosive environment or corrosive water 5.3.1.1.2 2.21 T 10 Years Sprinklers - Dry 5.3.1.1.1.5 2.22 T 20 Years Sprinklers - Fast Response 5.3.1.1.1.2 2.23 T 50 Years Sprinklers 5.3.1.1.1 2.24 T 75 Years Sprinklers 75 years in service 5.3.1.1.1.4 2.25 T Sprinklers manufactured prior to 1920 — Replace 5.3.1.1.1.1 3.1 M Annually Control Valves 12.3.4 3.2 M Annually Preaction /Deluge Valves 12.4.3.3.2 3.3 M Annually Dry Pipe Valves /Quick- Opening Devices 12.4.4.3.2 3.4 M Annually Dry Pipe Valve — Low Point Drains 12.4.4.3.3 3.5 M 5 Years Obstruction Investigation Chapter 13 State Fire Marshal AES 2 jurie 1 /, cuUo Item Inspection, Testing, and Maintenance Fire Sprinkler System NFPA 25 Chapter 5 as amended by CCR Title 19 Page 4 of 4 Date of Inspection, Testing, Maintenance: -- V) System Riser ID: Property Information: Name: R veirwgak Meoi G 0CAZ0. Type of ystem: Type Pipe o "1 Address: ?jQ S .e, K `1 u! y 0 Dry Pipe 0 Preaction D O Deluge Zl yj4EMA City: !94J&qxS 91 Zia See Continuation Page(s) _ Indicate the number of continuation pages) o FAILS Z-2-113 Signature Date Item Deficiencies and Comments: Deficiencies and Comments Item number must correspond to the Item number of the Activit listed above: 1) ,, K , o A% 1 See Continuation Page(s) _ Indicate the number of continuation pages) o FAILS Z-2-113 Signature Date State Fire Marshal AES 2 June 17, 2008