Loading...
HomeMy WebLinkAbout-Fire Suppression Systems Report 4/12/2012Pre - Engineered Restaurant -Fire Suppression Systems Report SERVICE L A ',;," CITY SERV,'S, INC. 5300 SO. UNION CA"EMISFoELD, CA 93307 -5426 6 1) 833 -5510 FAX 833 -5512 ti CUSTOMER Name Cx(C LG4CC, `FPt,tCsc E"oow5 Address 23 ( city 45 (-2 V1 State CA- ZI PqDDt Telephone If ' 327• D Z g Store No. Owner or.Manager 2 Ay ME-SA COOKING APPLIANCE LOCATIONS: LEFT TO RIGHT DATE OFS VICE TIME A.fj. P.M. 0/19 ,( 21. Check travel of cable nuts /S- hooks ANNUAL SEM7ALL RECHARGE INSTALLATION RENOVATION LOCATION OF SYSTEM CYLINDERS UL 300 Cir/ 511)e 4DF- - 5100ef4" YES AND MANUFACTURER MODEL NUMBER WET DRY CHEMICAL RO 25. Exhaust fan in operating order 7. If system has been discharged, report same V 26. All filters in place 8. Pressure gauge in proper range (If gauged) CYLINDER SIZE MASTER CYLINDER SIZE SLAVE CYLINDER SIZE SLAVE PCT SO A9(, PC -1 2 AJ3C 28. Manual & remote set/seals in place FUSE LINKS 360° F. FUSE LINKS 450° F. FUSE LINKS 500° F. OTHER 11. 6 year maintenance date J FUEL SHUT -OFF ELECTRIC GAS SIZE AItz A11A 32. Clean cylinder & mount S PPL r 14. Test for proper operation from remote V1, 33. Fan warning sign on hood SERIAL NUMBER LAST HYDROTEST DATE LAST RECHARGE DATE 34. Personnel instructed in manual operation of system 16. Check operation, of- gas.yalve f MANUFACTURER'S MANUAL REFERENCE PAGE NUMBER: DRAWING NUMBER: DATE 1. All appliances properly covered w /correct nozzles 20. Replaced fuse links 2. Duct andplenum covered w /correct nozzles 21. Check travel of cable nuts /S- hooks 3. Check positioning of all nozzles. V/ 22. Piping & conduit securely bracketed 4. System installed in accordance w /MFG UL listing 23. Proper separation between fryers & flame 5. Hood /duct penetrations sealed w /weld or UL device 24. Proper clearance -flame to filters 6. Check if seals intact, evidence of tampering 25. Exhaust fan in operating order 7. If system has been discharged, report same V 26. All filters in place 8. Pressure gauge in proper range (If gauged) V 27. Fuel shut -off in on position 9. Check cartridge weight (If applicable) 28. Manual & remote set/seals in place 10. Hydrostatic test date 7- 29. Replace systems covers 11. 6 year maintenance date 30. System operational & seals in place 12. Inspect cylinder and mount 31. Slave system operational 13. Operate system from terminal link V1.1 32. Clean cylinder & mount 14. Test for proper operation from remote V1, 33. Fan warning sign on hood 15. Check operation of micro switch 34. Personnel instructed in manual operation of system 16. Check operation, of- gas.yalve f 35. Proper hand portable extinguishers 17. Clean nozzles r r ~ 36. Portable extinguishers properly serviced 18. Proper nozzle covers in place o 37. Service & Certification tag on system 19. Check fuse links and clean NO NOTE DISCREPANICES OR DEFICIENCIES BELOW COMMENTS: On this date, this pre- engineered fire suppression system was inspected and operationally tested in accordance with the fire suppression system requirements of NFPA17 or 17A, 96 and the manufacturer's manual with the results indicated above. X R,6- A.4;4 ? /2, 111.12•/? l2 : /T I 1 V SERVICE TECHNICIAN PERMIT NO. DATE:' TIME: AM P 54__ RIZED AGENT The above service technician certifies that the system was personally inspected and found conditions to be as indicated on this report. AUTHORITY HAVING JURISDICTION