Loading...
HomeMy WebLinkAboutRange Hood Systems Report 10/24/2011Range Hood Systems Report AAA CUftLITY SERVICES, IONC. 5300 SO. UNION BAKERSFIELD, CA 93307 -54' -5 661) 833 -5510 FAX 833 -5 i CUSTOMER yy Name O G 4-f-c/('t• Gn i(C Address 2 3 City u /'( State 4& ZIP s Telephone 2 - Q2 6:6 Store No. Owner or Manager COOKING APPLIANCE LOCATIONS: LEFT TO RIGHT DATE OF SERVICE TIME A.M. 6 r_ ! 22. Piping & conduit securely bracketed 23. Proper separation between fryers & flame ANNUAL SEMI- ANN RECHARGE INSTALLATION RENOVATION 25. Exhaust fan in operating order UAL 6/ IZV-0 26. All filters in place LOCATION OF SYSTEM CYLINDERS UL 300 f ` f;jWeS' NO 28. Manual & remote set/seals in place T MANU ACTURER ODEL NUMBER WET DRY CHEMICAL. 30. System operational & seals in place V 31. Slave system operational 32. Clean cylinder & mount CYLINDER SIZE MASTER C91 NhF SIZE SLAVE CYLINDER SIZE SLAVE 34. Personnel instructed in manual operation of system FU INKS 360° F FUSE LINKS 450° F. FUSE LINKS 500° F OTHER FUEL SHUT -OFF ELECTRIC GAS SIZE NOTE DISCREPANICES OR DEFICIENCIES BELOW SERIAL NUMBER LAST HYDROTEST DATE LAST RECHARGE DATE MANUFACTURER'S MANUAL REFERENCE PAGE NUMBER: DRAWING NUMBER: DATE 1. All appliances properly covered w /correct nozzles 2. Duct and plenum covered w /correct nozzles 3. Check positioning of all nozzles. 4. System installed in accordance w /MFG UL listing 5. Hood /duct penetrations sealed w /weld or UL device 6. Check if seals intact, evidence of tampering 7. If system has been discharged, report same 8. Pressure gauge in proper range (If gauged) 9. Check cartridge weight (If applicable) 10. Hydrostatic test date 11. 6 year maintenance date 12. Inspect cylinder and mount 13. Operate system from terminal link 14. Test for proper operation from remote 15. Check operation of micro switch 16. Check operation of gas valve 17. Clean nozzles 18. Proper nozzle covers in place 19. Check fuse links and clean COMMENTS: On this date, this range hood fire suppression system was inspected and operationally tested in accordance with the fire suppression system requirements of NFPA17 or 17A, 96 and the manufacturer's manual, with the results indicated above. X SERVICE TECHNICIAN PERMIT NO. ' %D]kTE: c TIME: AM PM CUSTOMER'S AUTHORIZED AGENT The above service technician certifies that the system was personally inspected and found conditions'to be as indicated on this report. 20. Replaced fuse links 21. Check travel of cable nuts /S -hooks 22. Piping & conduit securely bracketed 23. Proper separation between fryers & flame 24. Proper clearance -flame to filters 25. Exhaust fan in operating order IZV-0 26. All filters in place 27. Fuel shut -off in on position T 28. Manual & remote set/seals in place T 29. Replace systems covers 4 30. System operational & seals in place V 31. Slave system operational 32. Clean cylinder & mount 7714 33. Fan warning sign on hood 34. Personnel instructed in manual operation of system 1T 35. Proper hand portable extinguishers 36. Portable extinguishers properly serviced 37. Service & Certification tag on system NOTE DISCREPANICES OR DEFICIENCIES BELOW On this date, this range hood fire suppression system was inspected and operationally tested in accordance with the fire suppression system requirements of NFPA17 or 17A, 96 and the manufacturer's manual, with the results indicated above. X SERVICE TECHNICIAN PERMIT NO. ' %D]kTE: c TIME: AM PM CUSTOMER'S AUTHORIZED AGENT The above service technician certifies that the system was personally inspected and found conditions'to be as indicated on this report.