HomeMy WebLinkAbout3150 PANAMAPre - Engineered Restaurant Fire Suppression Systems Report
SERVICE COMPANY
C I--i(
30. UNION
BAKL-2f :, D, CA 93307 -5425
661) L' 10 FAX 333 -5512
Name 0 1 0
Address -5
City) tl t State ZIP
Telephone Store No.
Owner or Manager
COOKING APPLIANCE LOCATIONS: LEFT TO FIGHT
DATE OF SERVICE TIME _ A.M. I P.M.
ANNUAL SEMI - ANNUAL RECHARGE INSTALLATION RENOVATIONI
LOCATION OF SYSTEMM CY,LIN ERS UL 300
lC; 5, W I // i YES NO
L )tip 'T°ar/
MANUFACTURER MODEL NUMBER WET DRY CHEMICAL
CYLINDER SIZE MASTER CYLINDER SIZE SLAVE CYLINDER SIZE SLAVE
FUSE LINKS 360° F. FUSE LINKS 450° F. FUSE LINKS 500° F. OTHER
FUEL SHUT -OFF ELECTRIC GAS SIZE
SERIAL NUMBER LAST HYDRO TEST DATE LAST RECHARGE DATE
1 7
MANUFACTURER'S MANUAL REFERENCE
PAGE NUMBER: DRAWING NUMBER: DATE
i,$ theoi l
r
1,/q EIVZ4 Al a!
1. All appliances properly covered w /correct nozzles
2. Duct and plenum covered w /correct nozzles
3. Check positioning of all nozzles.
4. System installed in accordance w /MFG UL listing
5. Hood /duct penetrations sealed w /weld or UL device
6. Check if seals intact, evidence of tampering
7. If system has been discharged, report same
8. Pressure gauge in proper range (If gauged)
9. Check cartridge weight (If applicable)
10. Hydrostatic test date
11. 6 year maintenance date
12. Inspect cylinder and mount
13. Operate system from terminal link
14. Test for proper operation from remote
15. Check operation of micro switch
16. Check operation of gas valve
17. Clean nozzles
18. Proper nozzle covers in place
19. Check fuse links and clean
r
COMMENTS:--144
20. Replaced fuse links
21. Check travel of cable nuts /S -hooks
22. Piping & conduit securely bracketed
23. Proper separation between fryers & flame
T+
24. Proper clearance -flame to filters
t 25. Exhaust fan in operating order 1
26. All filters in place
27. Fuel shut -off in on position
1 28. Manual & remote set/seals in place I
f 29. Replace systems covers
30. System operational & seals in place
31. Slave system operational
32. Clean cylinder & mount
j 33. Fan warning sign on hood
34. Personnel instructed in manual operation of system E
35. Proper hand portable extinguishers
36. Portable extinguishers properly serviced
37. Service & Certification tag on system
NOTE DISCREPANICES OR DEFICIENCIES BELOW
I
On this date, this pre- engineered fire suppression system was inspected and operationally tested in accordance with the fire.
suppression system requirements of NFPA17 or 17A, 96 and the manufacturer's manual with the results indicated above.
SERVICE TECHNICIAN PERMIT NO. DATE: TIME: AM PM ClJ$TOMER'S AUTHORIZED AGENT
The above service technician certifies that the system was personally inspected and found conditions to be as indicated on this report.
AUTHORITY HAVIMG JURISDICTION