HomeMy WebLinkAbout3150 PANAMA LANE (2)Pre - Engineered Restaurant Fire Suppression Systems Report AAA QUALITY SERVCCES, INC. 5800 SO. UNION BAKERSFIELD, CA 93307 -5426 661) 833 -5510 FAX 833 -5512 C, L CUSTOMER / Name y t.- l i y J 0rt Address 7 t-- J 7 n City l~ L- d J State ZIP Telephone Store No. Owner or Manager COOKING APPLIANCE LOCATIONS: LEFT TO RIGHT DATE OF SERVICE TIME A.M. P.M. 21. Check travel of cable nuts /S -hooks 3. Check positioning of all nozzles. 22. Piping & conduit securely bracketed 4. System installed in accordance w /MFG UL listing 23. Proper separation between fryers & flame ANNUAL SEMI - ANNUAL RECHARGE INSTALLATION RENOVATION 25. Exhaust fan in operating order 7. If system has been discharged," report same 26. All filters in place 8. Pressure gauge in proper range (If gauged) LOCATION OF SYSTEM CYLINDERS J / UL 300 v `! % YES NOt..! • ' ' " '? r; /: MANUFACTURER MODEL NUMBER 11. 6 year maintenance date DRY CHEMICAL 30. System operational & seals in place 12. Inspect cylinder and mount WET 31. Slave system operational CYLINDER SIZE MASTE CYLINDER SIZE SLAVE CYLINDER SIZE SLAVE T 33. Fan warning sign on hood FUSE LINKS 360° F. FUSE LINKS 450° F. FUSE LINKS 500" F. OTHER FUEL SHUT -OFF ELECTRIC GAS SIZE 36. Portable extinguishers properly serviced 18. Proper nozzle covers in place 37. Service & Certification tag on system SERIAL NUMBER LAST HYDRO TEST DATE LAST RECHARGE DATE 1 J MANUFACTURER'S MANUAL REFERENCE PAGE NUMBER: DRAWING NUMBER: DATE 1. All appliances properly covered w /correct nozzles 20. Replaced fuse links 2. Duct and plenum covered w /correct nozzles 21. Check travel of cable nuts /S -hooks 3. Check positioning of all nozzles. 22. Piping & conduit securely bracketed 4. System installed in accordance w /MFG UL listing 23. Proper separation between fryers & flame 5. Hood /duct penetrations sealed w /weld or UL device 1 r 24. Proper clearance -flame to filters 6. Check if seals intact, evidence of tampering 25. Exhaust fan in operating order 7. If system has been discharged," report same 26. All filters in place 8. Pressure gauge in proper range (If gauged) 27. Fuel shut -off in on position 9. Check cartridge weight (if applicable) i 28. Manual & remote set/seals in place 10. Hydrostatic test date 29. Replace systems covers 11. 6 year maintenance date f 30. System operational & seals in place 12. Inspect cylinder and mount 31. Slave system operational 13. Operate system from terminal link 32. Clean cylinder & mount 14. Test for proper operation from remote T 33. Fan warning sign on hood 15. Check operation of micro switch 1 34. Personnel instructed in manual operation of system 16. Check operation of gas valve 35. Proper hand portable extinguishers 17. Clean nozzles E 36. Portable extinguishers properly serviced 18. Proper nozzle covers in place 37. Service & Certification tag on system 19. Check fuse links and clean NOTE DISCREPANICES OR DEFICIENCIES BELOW COMMENTS: On this date, this pre- engineered fire suppression system was inspected and operationally tested in accordance with the fire suppression system requirements of NFPA17 or 17A, 96 and the manufacturer's manual with the results indicated above. SERVICE TECHNICIAN PERMIT NO. DATE: TIME: AM PM QUSTOMER'S AUTHORIZED AGENT The above service technician certifies that the system was personally inspected and found conditions to be as indicated on this report. AU7HOM7V bQF9U0 JdDMSMC' ltOM