HomeMy WebLinkAbout3150 PANAMA LANE (2)Pre - Engineered Restaurant Fire Suppression Systems Report
AAA QUALITY SERVCCES, INC.
5800 SO. UNION
BAKERSFIELD, CA 93307 -5426
661) 833 -5510 FAX 833 -5512
C, L
CUSTOMER /
Name y t.- l i y J 0rt
Address 7 t-- J 7
n
City l~ L- d J State ZIP
Telephone Store No.
Owner or Manager
COOKING APPLIANCE LOCATIONS: LEFT TO RIGHT
DATE OF SERVICE TIME A.M. P.M.
21. Check travel of cable nuts /S -hooks
3. Check positioning of all nozzles. 22. Piping & conduit securely bracketed
4. System installed in accordance w /MFG UL listing 23. Proper separation between fryers & flame
ANNUAL SEMI - ANNUAL RECHARGE INSTALLATION RENOVATION
25. Exhaust fan in operating order
7. If system has been discharged," report same 26. All filters in place
8. Pressure gauge in proper range (If gauged)
LOCATION OF SYSTEM CYLINDERS J / UL 300
v `! % YES NOt..! • ' ' " '? r; /:
MANUFACTURER MODEL NUMBER
11. 6 year maintenance date
DRY CHEMICAL
30. System operational & seals in place
12. Inspect cylinder and mount
WET
31. Slave system operational
CYLINDER SIZE MASTE CYLINDER SIZE SLAVE CYLINDER SIZE SLAVE
T 33. Fan warning sign on hood
FUSE LINKS 360° F. FUSE LINKS 450° F. FUSE LINKS 500" F. OTHER
FUEL SHUT -OFF ELECTRIC GAS SIZE
36. Portable extinguishers properly serviced
18. Proper nozzle covers in place 37. Service & Certification tag on system
SERIAL NUMBER LAST HYDRO TEST DATE LAST RECHARGE DATE
1 J
MANUFACTURER'S MANUAL REFERENCE
PAGE NUMBER: DRAWING NUMBER: DATE
1. All appliances properly covered w /correct nozzles 20. Replaced fuse links
2. Duct and plenum covered w /correct nozzles 21. Check travel of cable nuts /S -hooks
3. Check positioning of all nozzles. 22. Piping & conduit securely bracketed
4. System installed in accordance w /MFG UL listing 23. Proper separation between fryers & flame
5. Hood /duct penetrations sealed w /weld or UL device 1
r
24. Proper clearance -flame to filters
6. Check if seals intact, evidence of tampering 25. Exhaust fan in operating order
7. If system has been discharged," report same 26. All filters in place
8. Pressure gauge in proper range (If gauged) 27. Fuel shut -off in on position
9. Check cartridge weight (if applicable) i 28. Manual & remote set/seals in place
10. Hydrostatic test date 29. Replace systems covers
11. 6 year maintenance date f 30. System operational & seals in place
12. Inspect cylinder and mount 31. Slave system operational
13. Operate system from terminal link 32. Clean cylinder & mount
14. Test for proper operation from remote T 33. Fan warning sign on hood
15. Check operation of micro switch 1 34. Personnel instructed in manual operation of system
16. Check operation of gas valve 35. Proper hand portable extinguishers
17. Clean nozzles E 36. Portable extinguishers properly serviced
18. Proper nozzle covers in place 37. Service & Certification tag on system
19. Check fuse links and clean NOTE DISCREPANICES OR DEFICIENCIES BELOW
COMMENTS:
On this date, this pre- engineered fire suppression system was inspected and operationally tested in accordance with the fire
suppression system requirements of NFPA17 or 17A, 96 and the manufacturer's manual with the results indicated above.
SERVICE TECHNICIAN PERMIT NO. DATE: TIME: AM PM QUSTOMER'S AUTHORIZED AGENT
The above service technician certifies that the system was personally inspected and found conditions to be as indicated on this report.
AU7HOM7V bQF9U0 JdDMSMC' ltOM