Loading...
HomeMy WebLinkAbout3200 GOSFORD ROADPre - Engineered Restaurant Fire Suppression Systems Report SERVICE COMPANY / 7 GM QUALM SERVICES, INC. 5800 SO. UNION BAKERSFIELD, CA 93307 -5426 661 ) 833-5510 FAX 833 -5512 CUSTOMER Name 44 .4 - i Address /e_*::7 i/ I / '/ city State a 2z / Telephone EZ202- 12: eECE Store No. Owner or Manager ? rz'._ r =Zu"a/ COOKING APPLIANCE LOCATIONS: LEFT TO RIGHT 1. All appliances properly covered w /correct nozzles ` 2. Duct and plenum covered w /correct nozzles 3. Check positioning of all nozzles. 4. System installed in accordance w /MFG UL listing 5. Hood /duct penetrations sealed w /weld or UL device 6. Check if seals intact, evidence of tampering 7. If system has been discharged, report same 8. Pressure gauge in proper range (If gauged). 9. Check cartridge weight (If applicable) 10. Hydrostatic test date 11. 6 year maintenance date 12. Inspect cylinder and mount 13. Operate system from terminal link 14. Test for proper operation from remote 15. Check operation of micro switch 16. Check operation of gas valve 17. Clean nozzles 18. Proper nozzle covers in place i 19. Check fuse links and clean DATE OF SERV E TIME A.M. P.M. ANNUAL SEMI- ANNUAL 1. RECHARGE INSTALLATION RENOVATION LOCATION OF SYSTEM CYLINDERS UL 300 OF llalaD //I/ /T- YES C] NO MANUFACTURER MODEL NUMBER WET DRY CHEMICAL CYLINDER SIZE MASTER CYLINDER SIZE SLAVE CYLINDER SIZE SLAVE 2_5,;::;_,91_ FUSE LINKS 360° F. FUSE LINKS 450° F. FUSE LINKS 500° F. OTHER FUEL SHUT -OFF ELECTRIC GAS SIZE SERIAL NUMBER LAST HYDROTEST DATE LAST RECHARGE DATE OO MANUFACTURER'S MANUAL REFERENCE PAGE NUMBER: DRAWING NUMBER: DATE COMMENTS: 44_7-' 41 20. Replaced fuse links 21. Check travel of cable nuts /S -hooks 22. Piping & conduit securely bracketed 23. Proper separation between fryers & flame 24. Proper clearance -flame to filters 25. Exhaust fan in operating order 26. All filters in place 27. Fuel shut -off in on position 28. Manual & remote set/seals in place 29. Replace systems covers 30. System operational & seals in place 31. Slave system operational 32. Clean cylinder & mount 33. Fan warning sign on hood 34. Personnel instructed in manual operation of system 35. Proper hand portable extinguishers 36. Portable extinguishers properly serviced 37. Service & Certification tag on system NOTE DISCREPANICES OR DEFICIENCIES BELOW On this date, this pre- engineered fire suppression system was inspected and operationally tested in accordance with the fire suppression system requirements of NFPA17 or 17A, 96 and the manufacturer's manual with the results indicated above:' 8ERVICC14NICIAN PERMIT NO. DATE: TIME: AM PM C08TOMER7AUT1-16RIZED AGENT The above service technician certifies that the system was personally inspected and found conditions to be-as Indicated on this report. AUTHORITY HAVING JURISDICTION