HomeMy WebLinkAbout4044 MINGPre- Engineered Restaurant Fire Suppression Systems Report SERVICE COMPANY 0. 6 1' CUSTOMER Name 1 tt1_p( Address YIN I (i I ul City State ZIP Telephone Store No. Owner or Manager COOKING APPLIANCE LOCATIONS: LEFT TO RIGHT DATE OF SERVICE TIM -- -- A. P.M. 17_1 eyjf f)> 23. Proper separation between fryers & flame ANNUAL SEMI - ANNUAL RECHARGE INSTALLATION RENOVATION 26. All filters in place 0r 27. Fuel shut -off in on position LOCATION OF SYSTEM CYLINDERS UL 300 YES NO 29. Replace systems covers MANUFACTURER MODEL NUMBER WET DRY CHEMICAL 501 K 32. Clean cylinder & mount CYLINDER SIZE MASTER CYLINDER SIZE SLAVE CYLINDER SIZE SLAVE l A 34. Personnel instructed in manual operation of system FUSE LINKS 360° F. FUSE LINKS 450° F. FUSE LINKS 500° F OTHER 36. Portable extinguishers properly serviced FUEL SHUT-OFF ELE C GAS SIZE SERIAL NUMBER LAST HYDRO TEST DATE LAST RECHARGE DATE MANUFACTURER'S MANUAL REFERENCE PAGE NUMBER: DRAWING NUMBER: DATE 1 ' AAA f rlia I r i t 21. Check travel of cable nuts /S -hooks 22. Piping & conduit securely bracketed 23. Proper separation between fryers & flame 1. All appliances properly covered w /correct nozzles 2. Duct and plenum covered w /correct nozzles 3. Check positioning of all nozzles. 4. System installed in accordance w /MFG UL listing 5. Hood /duct penetrations sealed w /weld or UL device 6. Check if seals intact, evidence of tampering 7. If system has been discharged, report same 8. Pressure gauge in proper range (If gauged) 9. Check cartridge weight (If applicable) 10. Hydrostatic test date 11. 6 year maintenance date 12. Inspect cylinder and mount 13. Operate system from terminal link 14. Test for proper operation from remote 15. Check operation of micro switch 16. Check operation of gas valve 17. Clean nozzles 18. Proper nozzle covers in place 19. Check fuse links and clean, 1 r COMMENTS: al 10499, On this date, this pre- engineered fire suppression system was inspected and operationally tested in accordance with the fire suppression system requirements of NFPA17 or 17A, 96 and the manufacturer's manual with.the resultiindicated above. X 01- SERVICE TECHNICIAN PERMIT NO. DATE: TIME: AM PM 'CUSTOMER'S AUTHORIZED AGENT The above service technician certifies that the system was personally inspected and found conditions to be as indicated on this report. AUTHORITY HAVING JURISDICTION 20. Replaced fuse links i t 21. Check travel of cable nuts /S -hooks 22. Piping & conduit securely bracketed 23. Proper separation between fryers & flame I 24. Proper clearance -flame to filters 25. Exhaust fan in operating order i i%1 26. All filters in place 0r 27. Fuel shut -off in on position 28. Manual & remote set/seals in place 29. Replace systems covers r 30. System operational & seals in place E 31. Slave system operational 32. Clean cylinder & mount 1 33. Fan warning sign on hood 34. Personnel instructed in manual operation of system 7- 35. Proper hand portable extinguishers . 36. Portable extinguishers properly serviced 37. Service & Certification tag on system NOTE DISCREPANICES OR DEFICIENCIES BELOW On this date, this pre- engineered fire suppression system was inspected and operationally tested in accordance with the fire suppression system requirements of NFPA17 or 17A, 96 and the manufacturer's manual with.the resultiindicated above. X 01- SERVICE TECHNICIAN PERMIT NO. DATE: TIME: AM PM 'CUSTOMER'S AUTHORIZED AGENT The above service technician certifies that the system was personally inspected and found conditions to be as indicated on this report. AUTHORITY HAVING JURISDICTION