Loading...
HomeMy WebLinkAbout4044 MING AVENUEPre - Engineered Restaurant Fire Suppression Systems Report SERVICE COMPANY AAA ClUt"11TV f INC. DATE OF SERVICE 0V TIME . II > > A.M. P.M. ANNUAL SEMI - ANNUAL RECHARGE INSTALLATION RENOVATION LOCATION OF SYSTEM CYLINDERS UL 300 5800 SO. UNION BAKERSFIELD, CA 93307 -5426 601) 833 -5510 FAX 833 -5512 1JaF f ( ' j Y f EnYES (]NO MANUFACTURER MODEL NUMBER -F--/WET DRY CHEMICAL CYLINDER SIZE MASTER CYLINDE SIZE SLAVE CYLINDER SIZE SLAVE FUSE LINKS 360° F. i I FUSE LINKS 450° F FUSE LINKS 500° F. OTHER Name CUSTOMER t'p t -PCIMI (( 241 n Address i i% LI ! ! , i A1 i lir FUEL SHUT -OFF ELECTRIC L GAS SIZE i I y SERIAL NUMBER LAST HYDROTEST DATE LAST RECHARGE DATE 1 City ,1 t F ! i State ZIP t MANUFACTURER'S MANUAL REFERENCE Telephone Store No. PAGE NUMBER: DRAWING NUMBER: DATE Owner or Manager COOKING APPLIANCE LOCATIONS: LEFT TO RIGHT i1; V 1 r MI i A J A 1. All appliances properly covered w /correct nozzles 20. Replaced fuse links 2. Duct and plenum covered w /correct nozzles 1 21. Check travel of cable nuts /S -hooks 3. Check positioning of all nozzles. 22. Piping & conduit securely bracketed_ 4. System installed in accordance w /MFG UL listing EF 23. Proper separation between fryers & flame 5. Hood /duct penetrations sealed w /weld or UL device _J_ 24. Proper clearance -flame to filters 6. Check if seals intact, evidence of tampering 25. Exhaust fan in operating order 7. If system has been discharged, report same 26. All filters in place 8. Pressure gauge improper range (If gauged) 27. Fuel shut -off in on position T- 9. Check cartridge weight (If applicable) 28. Manual & remote set/seals in place y 10. Hydrostatic test date 29. Replace systems covers 11. 6 year maintenance date 1 30. System operational & seals in place 12. Inspect cylinder and mount 31. Slave system operational 13. Operate system from terminal link 32. Clean cylinder & mount 14. Test for proper operation from remote 33. Fan warning sign on hood 15. Check operation of micro switch 34. Personnel instructed in manual operation of system 16. Check operation of gas valve 35. Proper hand portable extinguishers 17. Clean nozzles 36. Portable extinguishers properly serviced 18. Proper nozzle covers in place 37. Service & Certification tag on system 19. Check fuse links and clean qq NOTE DISCREPANICES OR DEFICIENCIES BELOW COMMENTS: !-1. caP `,. ILA On this date, this pre - engineered fire suppression system was inspected and operationally tested in accordance with the fire suppression system requirements of NFPA17 or 17A, 96 and the manufacturer's manual wiA; tie result , sindicated above. G SERVICE TECHNICIAN PERMIT NO. DATE: TIME: AM PM USTOMER'S AUTHORIZED AGENT it The above service technician certifies that the system was personally inspected and found condi ions to be as indicated on this report. AU7H0RVTV HAV7V ,10 JU==70M