Loading...
HomeMy WebLinkAboutAST INSP 3/22/2013UNIFIED PROGRAM INSPECTION CHECKLIST Aboveground Petroleum Storage Tank Program BAKERSFIELD FIRE DEPT. L H s P t Prevention Services FIRE 2101 H StreetARTMr Bakersfield, CA 93301 Tel.: (661) 326 -3979 Fax: (661) 852 -2171 FACILITY NAME INSP CTION DATE I _1 I Z- INSPECTION TIME ADDRESS , ! 1 .1 I 1 vV P S JlNOS.94 NO OF EMPLOYEES FACILITY CONTACT 1l111 t 1rC. i'1G r9cGSf BUSINESS ID NUMBER ONSENT TO INSPECT NAME /TITLE SECTION 1: Records Review: California Health & Safety Code: 25270 DESCRIPTION YJ N N/A COMMENTS Prepare an SPCC plan [CFR 112.3 to Review or amend SPCC plan [CFR 112.5 (a)(d) 10 SPCC plan available on site [CFR 112.3 e Conduct inspections and test in accordance with written procedures [CFR 112.7 e 0 7 Maintain records of inspections, tests and/or procedures [CFR 1 12.7 e o Records of inspections or tests signed by inspector [CFR 112.7 (e) b SECTION 2: SPCC Plan Elements: California Health & Safety Code: 25270.4.5. 25270.12 DESCRIPTION Y N N/A COMMENTS Self- certification for Tier I or II facility 112.6 (a) (1), b 1) Professional engineer certification CFRI 12.3(d) and 112.6(b)(4)] Documentation of5 year review and evaluation ofSPCC plan [CFR 112.5(b)] Amendments required within 6 months of changes/certifications [CFR 112.5 (a) and II2.6(a)(2 ), (b)(4)] O 7 Management authorization of resource commitment to implement the SPCC [CFR 112.7 & 112.6(a)] o Diagram with location and contents ofcontainers, transfer stations, connecting piping 112.7(a)(3) b T e'of oil and storage capacity for each container [CFR 112.7(a)(3)] b Discharge prevention measures and procedures for routine handling CFR 112.7(a)(3)] o Countermeasures for discovery, response and clean-up CFR112.7(a)(3) 10 Required contact list and phone numbers [CFR I I2.7(a)(3) SECTION 3- General SPCC Renuirements- California Health & Safety Code: 25270.4.5. 25270.5. 25270.12 DESCRIPTION Y N N/A COMMENTS Provide corrosion protection [CFR 1 12.8 c 4 5), (d)(1)] Containers compatible with materials stored [CFR 112.8(c)(1)] Implement SPCC plan review changes or amendments within 6 months [CFR 112.5 a d Prepare an oil contingency Ian or written control /removal commitments [CFR 1 12.7(d) O SECTION 4: SPCC Plan Trainina: California Health & Safety Code: 25270.4.5 DESCRIPTION Y N N/A COMMENTS Training program [CFR 112.7 f) Train personnel in operation and maintenance of equipment CFR 112.7 Conduct annuals ill prevention briefings [CFR 112.7(0(3)] SECTION 5: Facility Insnection: California Health & Safety Code: 25270.4.5 DESCRIPTION Y N N/A COMMENTS Meet provisions of conditional exemption [H &S 25270.4.5 b Facility security adequate [CFR 112.7(g)] Clean-up materials readily available [CFR 112.7 c Overfill protection procedures or devices in place and operative [CFR 112.8(c)(8 Portable /mobile containers positioned to prevent discharge [CFR 112.8 (c) (11) Loading / unloading rack drains into containment area [CFR 112.7(h)] Provide appropriate containment /diversionary structures to prevent discharge [CFR 112.8(a), 112.7(c)] b Secondary containment adequate to contain capacity of largest container + precipitation [CFR 1 12.8(c)] Remove accumulation of oil in secondary containment [CFR 112.8 (c) (10) 10 Secondary containment valves closed [CFR 112.8 Implement SPCC plan elements [CFR 112.31 30 NY HAZARDOUS WASTE ON SITE? 'LYES NO i natureofRecei t p / xplain: POST INSPECTION INSTRUCTIONS: Refer to the back ofthis inspection report for regulatory citations and corrective actions Correct the violation(s) noted above by Within 5 days of correcting all ofthe violations, sign and return a copy of this page to: Bakersfield Fire Dept., Prevention Services, 2101 H Street, California 93301 Signature (that all violations have been corrected as noted) 4 Date White- Business Copy Yellow - Business Copy to be Sent inafter return to Compliance Pink- Prevention Services Copy FD2156b (Rev 9/10) m