Loading...
HomeMy WebLinkAboutFIRE SUPPRESSIN SYSTEM REP 9/24/2012Pre - Engineered Restaurant" Fire Suppression Systems Report hM QUAUTY SERVICES, INC. 5300 S0. UNNION BAKERSFIELD, Cry 93307 -5426 661) 833 -5510 FAX 833 -5x12 Name I-10 P _: - 0 Address q ?_ -Z I -S • f 7 _ 5+ City l`7 ,- t:L State n ZIP _'13_3024 Telephone Store No. Owner or Manager D[ ATE OF SERVICE TIME A. A.M. P.M. r i ; v° a e ANNUAL SEMI - ANNUAL RECHARGE INSTALLATION RENOVATIONI LOCATION OF SYSTEM CYLINDERS UL300 0 f ; loo 4:> QYES NO MANUFACTURER MODEL NUMBER WET DRY CHEMICAL CYLINDER SIZE MASTER CYLINDER SIZE SLAVE CYLINDER SIZE SLAVE 33,1 721 FUSE LINKS 360° F. FUSE LINKS 450° F. FUSE LINKS 500° F. OTHER 0 3 FUEL SHUT -OFF ELECTRIC GAS SIZE SERIAL NUMBER LAST HYDRO TEST DATE LAST RECHARGE DATE r 0 -T 0.S" MANUFACTURE 'S MANUAL REFERENCE PAGE NUMBER: DRAWING NUMBER: DATE COOKING APPLIANCE LOCATIONS: LEFT TO RIGHT 0 v e ov r:- o C i,,7 r roj I -e r i ; v° a e 1. All appliances properly covered w /correct nozzles 2. Duct and plenum covered w /correct nozzles P. Check positioning of all nozzles. 4. System installed in accordance w /MFG UL listing 5. Hood /duct penetrations sealed w /weld or UL device 6. Check if seals intact, evidence of tampering 7. If system has been " d: ischarged, report same 8. Pressure gauge in proper range (If gauged) 9. Check cartridge weight (If applicable) 10. Hydrostatic test date 11. 6 year maintenance date 12. Inspect cylinder and mount 13. Operate system from terminal link 14. Test for proper operation from remote 15. Check operation of micro switch 16. Check operation of gas valve 17. Clean nozzles 18. Proper nozzle covers in place 19. Check fuse links and clean COMMENTS: 20. Replaced fuse links 3 21. Check travel of cable nuts /S -hooks 22. Piping & conduit securely bracketed . 23. Proper separation between fryers & flame 1 24. Proper clearance -flame to filters f t 25. Exhaust fan in operating order 26. All filters in place J-- d 1 27. Fuel shut -off in on position 28. Manual & remote set/seals in place 29. Replace systems covers i 30. System operational & seals in place - 31. Slave system operational i- 32. Clean cylinder & mount 9 33. Fan warning sign on hood 34. Personnel instructed in manual operation of system 35. Proper hand portable extinguishers Q 36. Portable extinguishers properly serviced 37. Service & Certification tag on system N NOTE DISCREPANICES OR DEFICIENCIES BELOW Vto F ? 111 1 1 ..d t/ "-' ( 1) r, ^ '' , 11 . _. A, 1 T • 4 On this date, this pre- engineered fire suppression system was inspected and operationally, tested in accordancewith the fire suppression system requirements of NFPA17 or 17A, 96 and the manufacturer's manual with the results indicated above. X ' "'} I C,I -L f-f L l•( tit SERVICE TECHNICIAN PERMIT NO. DATE: TIME: AM PM CUSTOMER'S AUTHORIZED AGENT The above service technician certifies that the system was personally inspected and found conditions to be as indicated on this report. AUiTHOR11 TV HAV(I G dURMDIiCTIOM