Loading...
HomeMy WebLinkAbout#725 Fire Safety 7-23-11H FIRE PREVENTION INSPECTION B x a R S P I R D FIRE A f BAKERSFIELD FIRE DEPARTMENT Prevention Services 1501 Truxtun Avenue 1St Floor Bakersfield, CA 93301 Phone: 661-326-3979 • Fax: 661-852-2171 rs DISTRICT BLOCK NO. DATE 2 -. EE FACILITY ADDRESS 1 CITY, STATE, ZIP FACILITY NAME 1 . k MANAGER'S NAME PH NO. BUSINESS OWNER'S NAME AND ADDRESS CITY, STATE, ZIP PH NO. BILL (IF DIFFEREN FRO VE) NA E, ADDRESSt TYY STATE, ZI , OCC TYPE OCC LOAD NO. OF FLOORS HIGH RISE BLDG RISER DATE YES NO CORRECT ALL VIOLATIONS VIOLA ION REQUIREMENTS CHECKED BELOW NO. I Remove and safely dispose of all hazardous refuse and dry vegetation on the above premises (CFC COMBUSTIBLE WASTE / DRY VEGETATION 304.1.1 ) 2 Provide non - combustible containers with tight fitting lids for the storage of combustible waste and rubbish pending Its safe disposal. (CFC 304.3.1) COMBUSTIBLE STORAGE 3 Relocate combustible storage to provide at least 3 feet clearance around motor fuse box /fire door (CFC 605.3) 4 Relocate fire extinguisher(s) so that they will be in a conspicuous location, hanging on brackets with the top to the extinguisher not more than 5 feet above the floor. (CFC 906.5 & 906.9) EXTINGUISHERS 5 Provide and Install ( amount ) _____ approved (type & size __________________ portable fire extinguisher to be immediately accessible for use in (area) _____________________________ (CFC TABLE 906.3(1)) 6 Re- charge all fire extinguishers. Fire extinguishers shall be serviced at least once each year, and /or after each use, by a person having a valid license or certificate. (CCR TITLE 19: 575.1) 7 Provide and maintain "EXIT" sign(s) with letters 5 or more inches in height over each required exit SIGNS door /window) to fire escape. (CFC 1011.5.1) 8 Provide and maintain appropriate numbers on a contrasting background and visible from the street to indicate the correct address of the building. (CFC 505) 9 Repair all (cracks /holes /openings) in plaster in (location) ________ ______________________________. FIRE DOORS/ FIRE SEPARATIONS Plastering shall return the surface to its original fire resistive condition. (CFC 703.1) 10 Remove /repair(item &location) ___________________________ ______________________________. Self - closing doors shall be designed to close by gravity, or by the action of a mechanical device, or by an approved smoke and heat sensitive device. Self- closing doors shall have no attachments capable of preventing the operation of the closing device. (CFC 703.2) EXITS 11 Remove all obstruction from hallways. Maintain all means of egress free of any storage. (CFC 1028.3) 12 Provide a contrasting colored and permanently installed electric light over or near required exit location) ______________________________ to clearly indicate it as an exit. (CFC 2403.12.6) STORAGE 13 Remove all storage and /or other obstructions from fire escape landings and stairways stair shafts. (Fire escapes /stair shafts are to be maintained free from obstructions at all times.) (CFC 1028.3) 14 Extension cords shall not be used in lieu of permanent approved wiring. Install additional approved ELECTRICAL APPLIANCES electrical outlets where needed. (CFC 605.5) 15 Remove multiple attachment cords from specific electrical convenience outlet (one plug per outlet) (CFC 605.4) OUTDOOR BURNING 16 Recreational fires or open burning. CFC 1102 FIREWORKS 17 Violations of Section 7802 (CFC) & 8.49.040 (B.M.C.). OTHER 18 t"__pkM -to(- eco(\d '-___)M e CUSTOMER: LEGEND: gnat ) (Please Print Name Legibly, Tid C.F.C. CALIFORNIA FIRE CODE C. B, C. CALIFORNIA BUILDING CODE B.M.C. BAKERSFIELD MUNICIPAL CODE INSPECTOR: AP NO.: N.F.P.A. NATIONAL FIRE PROTECTION re ASSOCIATION N.E.C. NATIONAL ELECTRIC CODE FD 2022 (Rev, 03/08) White - Customer /Original Yellow - Station Copy Pink - Prevention Services