Loading...
HomeMy WebLinkAbout11101 178 HWY (7)MONITORING SYSTEM CERTIFICATION Pa55 For Use By All Jurisdictions Within the State ofCalifornia Authority Cited: Chapter 6 7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner /operator. The owner /operator must submit a copy of this form to the local agency regulating UST systems within 30 days of this date. A. General Information Facility Name: Mesa Marin Food Mart Site Address: 11101 Highway 178 City: Bakersfield Facility Contact Person: Moe Make /Model of Monitoring System: Veeder -Root TLS 350 B. Inventory of Equipment Tested /CertifiedChecktheappropriateboxestoIndicatespecificequipmentinspectediserviced: Bldg. No.: Zip: 93306 Contact Phone No.: 661 - 3664886 Date of Testing/Servicing: 01/4/2012 Tank ID: 10000 gal. Regular Tank x] ID: 10000 gal. Plus In -Tank Gauging Probe. Model: 847390 -107UIn -Tank Gauging Probe. Model: 847390-107 Annular Space or Vault Probe. Model: Annular Space or Vault Sensor. Model: Piping Sump / Trench Sensor(s). Model: Piping Sump / Trench Sensor(s). Model: Fill Sump Sensor(s) Model: Fill Sump Sensor(s). Model: Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: X] Electronic Line Leak Detector. Model: WPLLD U Electronic Line Leak Detector. Model: WPLLD x] Tank Overfill / High Level Sensor. Model: 847390 -107 Tank Overfill / High Leval Sensor. Model: 847390 -107 Other (specify equip, type and model in Sec. E on Pg. 2) Other (specify equip. type and model in Sec. E on Pg. 2) Tank ID: 10000 gal. Super Tank ID: 10000 gal. Diesel x] In -Tank Gauging Probe. Mode1:847390-107 x] In -Tank Gauging Probe. Model: 847390 -107 Annular Space or Vault Sensor. Model: Annular Space or Vault Sensor. Model: Piping Sump / Trench Sensor(s). Model: Piping Sump / Trench Sensor(s). Model: Fill Sump Sensors(s). Model: Fill Sump Sensor(s). Model: Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: x] Electronic Line Leak Detector. Model:WPLLD x] Electronic Line Leak Detector. Model: WPLLD x] Tank Overfill / High Level Sensor. Model: 847390-107 x] Tank Overfill / High Level Sensor. Model: 847390 -107 Other (specify equip. type and model in Sec. E on Pg. 2) Other (specify equip. typs and model in Sec. E on Pg. 2) Dispenser ID: 1 8t 2 Dispenser ID: 3 8t 4 Dispenser Containment Sensor(s). Model: Dispenser Containment Sensor(s). Model: X] Shear Valve(s). x] Shear Valve(s). x] Dispenser Containment Float(s) and Chain(s). X] Dispenser Containment Float(s) and Chain(s) Dispenser ID: Dispenser ID: Dispenser Containment Sensor(s). Model: Dispenser Containment Sensor(s). Model: Shear Valve(s). Shear Valve(s). Dispenser Containment Float(s) and Chains(s). Dispenser Containment Float(s) and Chain(s). Dispenser ID: Dispenser ID: Dispenser Containment Sensor(s). Model: Dispenser Containment Sensor(s). Model: Shear Valve(s). Shear Valve(s). Dispenser Containment Float(s) and Chain(s) Dispenser Containment Float(s) and Chain(s). If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. C. Certification -1 certify that the equipment identified in this document was inspected /seryices in accordance with the manufacturers' guidlines. Attached to this Certification is information (e.g. manufacturers' checklist) necessary to varify that this information is correct and a plot plan showing the layout of monitoring equipment. For equipment capable of generating such reports, I have attached a copy of the report; (check all that apply) x System Set -up x] Alarm his ry report Technician Name (print): Bradley Seykora Signature: Certification No: B40738 License No: 80490 Testing Company Name: Confidence UST Services, Inc. Phone No: 800 - 339 -9930 Site Address: 11101 Highway 178, Bakersfield, CA 93306 Date of Testing/Servicing: 0114/2012 D. Results of Testing /Servicing Software Version Installed: 14.00 Complete the following checklist: Lx] Yes No* Is the audible alarm operational? rxj Yes No* Is the Visual alarm operational? Yes F I No* Were all sensors visually inspected, functionally tested, and confirmed operational? Yes No* Were all sensors installed at the lowest point of secondary containment and positioned so that other equipment will not interfere with their proper operation? Yes No* If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) Hx N/A operational? x Yes No* For pressurized piping systems, does the turbine automatically shut down if the piping secondary N/A containment monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initate positive shut -down? Sump /Trench Sensors El Dispenser Containment Sensors Did you confirm positive shut -down due to leaks and sensor failure /disconnected? [X] Yes; No; U Yes No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no II N/A mechanical overfill prevention valve is installed), is the overfill warning alarm visual and audible at the tank fill point(s) and operating properly? If so, at what percent of tank capasity does the alarm trigger? 90 % Yes* F_ 1 No Was any monitoring equipment replaced? If Yes, identify specific sensors, probes, or other equipment replaced and list the manufacturer name and model for all replacement parts in Section E, below. U Yes* No Was liquid found inside any secondary containment systems designed as dry systems? Product; Fxl Water. If yes, describe causes in Section E, below. x No* Was monitoring system set -up reviewed to ensure proper settings? Attach set -up reports, if applicable. Lx_J Yes 10 No* I Is all monitoring equipment operational per manufacturer's specifications? In Section E below, discribe how and when these deficiencies were or will be corrected. E. Comments: Roughly 15 gallons of water was removed from the diesel STP. F. In -Tank Guaging / SIR Equipment: [X] Check this box if tank guaging is used only for inventory control. Check this box if tank guaging or SIR equipment is installed. This section must be completed if in -tank guaging equipment is used to perform leak detection monitoring. Complete the following checklist: X] Yes No* Has all input wiring been inspected for proper enter and termination,including testing for ground faults? x Yes No* Were all tank guaging probes visually inspected for damage and residue buildup? x Yes No* Was accuracy of system product level readings tested? Fxj Yes No* Was accuracy of system water level readings tested? x Yes No* Were all probes reinstalled properly? Lx] Yes No* Were all items on the equipment manufacturer's maintenance checklist completed? In the Section H, below; describe how and when these deficiencies were or will be corrected. G. Line Leak Detectors (LLD): Check this box if LLD's are not installed. Complete the following checklist: x Yes No* For equip. start -up or annual equipment certification, was a leak simulated to varify LLD performance? Check all that apply) Simulated leak rate: [x]3 g.p.h.: 0.1 g.p.h.; 00.2 g.p.h.; x Yes No* Were all LLD's confirmed operational and accurate within regulatory requirments? x Yes D No* Was the testing apparatus properly calibrated? Yes No* For mac amcal LLD's, does the LLD restrict product flow if it detects a leak? x N/A x] Yes No* For electronic LLD's, does the turbine automatically shut off ifthe LLD detects a leak? N/A Lx] Yes No* For electronic LLD's, does the turbine automatically shut off if any portion of the monitoring system is N/A disabled or disconnected? rx] Yes No* For electronic LLD's, does the turbine automatically shut off if any portion of the monitoring system N/A malfunction or fails a test? Yes No* For electronic LLD's, have all accessible wiring connections been visually inspected? N/A Lxj Yes No I Were all items on.the equipment manufacturer's maintenance checklist completed? In the section H, below, describe how and when these deficiencies were or will be corrected. H. Comments: HFsH I-IHRI 1-1 PIT 3Tl,+, VvAREET 11101 1-114Y 176 B;AK•NSFILLD-s`fA 9.-1306 JHN 4. 2012 6:46 AN v,Ll. FUHl'T 10 NORMAL I NfVENTOR'4' DEPORT f VOLMF = 5.140 GALS I1I-1-mr;C 4545 r;i-il.!3 90*1 LfL1-H,,-Lz 354C. (.4ALS TC VOLIRIE = 05405 GAL HE I (:HT = 0 .77 1 NCHES' 61HTEP 1 /01. Ci C ; oLl.-'; WATER' = 0 .00- 1 NCHE:'.' TEIIIP G9. 0 DEC F T :flits 1. VOLUME . 391.6 ULLA-.X- 60113 90'. lil-l-w: 5020 TC* ViAM-iE - 3945 ':;,ALS HE I i'.V 11' = 15.74 1 NCHES WIATEP Ve -L n 0 C;mLs WsATFJ? 0.00 1 f+,HE; TEMP 70.8 LiM F T .3:::!Lll -P UNLEADED vol-1.111F . 282;1 l31•iI-13 IJLI.iA(;E . 7154 l3wil-S 901 IJLI.i-v!E= 61' S Tc• vol i li iE - 2809 13, ALS HEI 13H I - 30.47 1 "':'HES 4"TEP Vr)L 10 WATER m 0.00 TEM!" 70.9 DEG F T 4:10-6 VOLUI iE 2Fj -? u JtiN 4 - '201:! 4t• All ULLA,.;E 7159 1:: P LS 1;0% 611:0 ALP' Tl' VOLUME 0i)3 GH I - S kt I i::Hl' 10.9,1 1 N;l tE 61ATEP VC4 0 LS WATER 0 . Cif, I m4'HE'S Tair. 71 .4 r,E-.-. F Z. A x :- • END *- t A '. -t SUF11 liPL XEV 1`: I ON LEVLL VEPSNIJ I -i.uo SOFT144PLII J,1601.1-100-k REATElf - SIV13TEN Fl*,,,TIJRFP,: pDmewi, m-nim: ANN U;il- I I,I-TFOO: TE--,'I'S PREC' 1:31 oli PLLD SYSTID-1 E-ETUP III I CAT Olt-; SETUP JtiN 4 - '201:! 4t• All PORT SL'ITINt;S: LINIII; Will 130i-iPP I (R-S-2S2> U.S. BAUD RATE 9600 S11STEm LANGLI il,E PAR I TY EVEN STFIl fjHI*E. T I Mr VORM14T rihTm LEP11:111: 7 DiiTr; M DD YYY%, MESH VIARIIII oiTO TR,-II )S,IIT SE171PIT ::,,rop moo -i:E,r 11101 o'lly 178 AUTO LE;A' A41J0,1 1-11-IIT 1) 1 SABLED i4UT0 Hli*;H WtiTEP 1-11,11T SHIFT TIME 1 .1:,30 ",1 1) 1 SmULEDI - THIE L I jASLED AUTO OVFPU-'[ 1.1. L 11-11 T SH I rr TI I IE 3 f; 12i-iBLED D I -SABLED SHIFT TIME 4 D IS ;4hLEr, AI.ITO LOW PRoLlurr FAI-'R I UL, I t-, TE':,'-r w., :N i iqil-cl Auro i*HEr,r L I I'l I T I) SABLE1 i-if-VII.IAL t-jj-jkjq I j,jt-;S AuTo DEL IVER", )t,TART DISmOLEL, 1) 1 SABLED AUTO DEL I VLRY ENDPRINTTCVOLUMESrl1SAHLED AUTO EXTERNAL I 111•UT ON P I SABLED TD,;F- , n-irEpisATioii AUTO E'TERNo4l- ipjr•ur ory V'-iLIJE (DEC F r-,ij, it ft I 2AULED AUTO SENSOR FUEL ALAFTI11-f•ROT04"OL 106(48LErl HE.1(;l1IT AUTO SENSOP u;iTEP t-q-i4RjlHE-DIRECT LOCiil. PP I m-oLrr b I WLED 1) I!:;r-iSLE[) Airro SE111SOP OUT HLiiRI•I SE,`UR ITY ODE : i)rjoCLio I CIA, OF I*IE'!;SFAl';E I N -i'r my SITUP T 2: L I E=: EI. T 3: SUPER uPILEAC,ED PPODW:'T CODE PROLLII_'T CODE 3 PHERh1AL COEFF :.U004713 THEPHfAL CrEFF :. M Nfi T I: UP1LF.1401 THrll'. D 1 w -IETER 95.00 THPIK D I I;hIETEF 95.170 PRODUCT COLE I TAW.' PROFILE I RT TANK PROFILE 1 PT THERMAL + ^EFF :.000700 FULL VOL 1On0:`t FULL VOL 10003 TANK G I rlNh: TIT 95 XO TANK PROFILE I PT FULL 't %OL 10003 FLT0 SIZE: 40i_I I N 806 RAW' 2 ME: 4. 0 1 N . 06, I,,APPllIV(:; 2.0 WHTEP I,.HRNIHC 0 FLOAT IP1. 9496 HI<:II WHTEP, LIPIIT: 3.0 HIGH 6"TER LMIT: 3.0 WATER WARN I NG 2 . U MHX OR LABEL VOL : 9985 I"IF1i: OR LHEIEL VOL: C196`, HIGH WATER L IH I T: 3.0 OVERFILL I-11-11T 5011. C;VEkl =1 I-1- L I Pa I "1' 901. 13986 3986 IvWX OR LABEL VOL: 9985 1.11,::H PRODUCT 953. H I, H PRODUCT 95% OVERFILL LIMIT 90., 9,195 9.1135 8986 DELIVERY LIMIT Mi. DELIVERY L I FI I T 10",:, H I CH PRC'LIJ+ T 95 > 60LI I IJUu 985 DEL l VER K L RH1M 7 15% LOW F'R•:1Dun 500 LOI,.1 PF.orn.10f 5017 1500 LEHI: ALAJAq I . I M I T : 99 LEA}: ALARM L I M I T : 99 5UDL1f -N LO5'S 1.111 I T : 99 SUDDEN LOSS LIMIT: 99 LOW F'RODLb:'T 500 TANK. TILT 0.20 TANK TI LT I .04 LEA).* HI.HRI.1 L 111 I T : 99 JWDDEN LOSS LIMIT: 9,1 Ili-ill 1 FOLDELi THNI.S Mhly 1 FOLDL•'U Tr•;I•lES Two, T I LT 0.::t0 TN : NONE TO: NONE MAN 1 FOLDED TmK:; TO: NONE LEmK P1IN PET OU1+": 15% L }EiiK MIN PER!C;LIC: I5% 1 500 1 500 LEAK H f Iv hER I cm I +:': 15% LEAK I•I I N fiNPNM& IT. . LEAK L9 f N I,NNLk=1L 15" v 1500 1500 1500 I-Bill MIN i7h1 OML 1 ` "a 1500 PIER I Ob I + :: TEST T`,TE PEN I OD 1C TEST TYPE STSHVI: HRf1 TrHVLr -118'0 PER I oD 11" TENT T`, PF. FihlPll.II.1l. 'PEST FOIL ANNIJI -+L 'f1 :5'I' FH I L J'ff1Nf I`:I f;LAR1 °I 4LARH . D l :=:Af3Lr:r, ANNUTAL `I'E : T Fhl I L Tr-'!-'.;'I" f =H1 L PEN: I OD I i' TEST FAIL. ALARIV 1+l 101.1=r+ ml-A H ML iR! °I LI: r;h71.tL+ PER[ IC TEST FA I L GROSS TEST FAIL. FH I I . All= D I X81- r, Al..r-;F:1.1 E1'4FiBLEL AL:;RI "I ENAI "iLEr, GROSS TEafFAIL AN1v TEST r•,vEPHC:lriC;: OFF ANN 1'Ei_T mVLEA,71N,::: OFF ALi -4f;1h ENHbI.F.I. PER TEST AWERAC I NI.: OFF PER TE:9T HVERfAG I NC:: iFF ANN TEi:'f a;VEL'H+; I N1; : A F THPU; "l'C:; T NOT 1 F'/ : 014 TAI.11: TEST PER TE21' r;;;I:G:A+::I N11: 431=8 TNIQ 'I w SIPHON BREmK C•FI•' TPU: TST ,;:1 PHON THNE TEST rv:T:F'Y: ON DELIVERY 1!ELAY 1 1,111-1 DEL I VEF:'f (IELtiY T H I N ME TsT SIPHON BREmA OFI fiEL 1 VEPY LELHY I M 1 III T t :PLUS TI-11J.1-IML COEFF :.0007uo rwo., pipmETER 95.01) TWO: PIROF I LL I PT FULL %/01 10C., 01 FLOHT 4.0 IN. 8.136 WiTER WARN MC. 2.0 I-1101 WATER LIMIT: 3.0 PVA* * QP LMREL VOL: 99935 OVERFILL I.Iiill' 9tr, 8966 lflGK 9514 MLIVLp", 1006 LAW PRoril le'l, 500 LE;il: HL mPti 1.111IT: 99 23111DEN Lo!:-", LIMIT: 9Ci TFMY T I LT 11,411FOU'r-Ii TONK.S TO: M)NE LEH). HIUI MPIMPIC: I S. PER101,11" MiT IYJE sT;,I,If+ipD i-INNIJoL, '11,,fl' FWL. PERI%)DK TEAT Fvill- i,;K'a TEST ALIAPN EPli-AiM, W01 TEST %;FF r,r-p Ti I' Or-F i*fim: NoTIFY: ON TPIK TST .-;IPHOPI riRI71HK:(A--F DELIVER, 11EL.Fi% : I I'll III LEE, M-.'T METHOD TEST WEEI'I.* Il rill. Teill)-' motl sThp,r r)m- TEST RmTE C;hl. HR DtIRH'riof,i 2, FIULIF LEHI: TEM REPOW R:-FW;T Mopl,itil- PRESUAd? LINE LE;i; SETUP 11 1 :UNLEmPED PIPE TVPE: :-J PEEL LINE LENr;'11i: 'iO FLE-r n,20 cipij 'rES*r: E1,94BI.I.71f 01. 10 GPH I*Mi:T: D HuTpowi RATE: 3.1.I FFI T I :1.11,11-EmDEF, S.TAODARD GEPISOR: N,,)14-VI:*IrI'E(, f..') : Li I ES.U. PIPE TYPE: STLU. 1,1111 I.Eilpmi: -Al FEET 0.20 C;PH Mf:* Eumpi-Ers o.io 6.pi,i TEST: Lolf.:;mBLED HUTDOIA111 P;ATE: 2.0 '>H T 2:1:11MEI. SEIISOR: 11011-VENTED 0 3:::;UPEP UNI-D-iMl.) F,wi: *r'PE: STEM.L. LANE ]-ENC;'rw 1-60 Fr-ET 0.22 (,'F'H TEP,T: ENIABI-Er, 0. IQ GPH TEST: DI S70EILEL, 21AITElOWN CPh T 3:SUPEP UNLEADED j I.SPEMSE MODE: ID 4: PI.UC PIPE '1','PE: .1.;1 EEL LINE LEPtrTI4: K,) FEET O.':'D GPH TEsT:- EI,IADLEb 0-10 GPH TE.,j: SHUTDOWN Rml,c: 3.0 Gpli T 4: PLUS MODE: 2TAM)HRT- SENWIR: 1,1014-keCtrfEb OUTPLU RE[-j;', SM*tll, R I :UVERFILL Hl. &,I I rl- THPIK H41APNS i4LL:OVERFIIJ- (Al.id-1-1 MLL:11104 PrObtfill' HLikPI-1 PLLD LINE I: SMUP I WNI-ErADED NO MI-AI 1'1 ASS11"'PILENTS - L, I 24CL 116 Al-mKI - NO t-iIjAF1*I 14 4 : PLLFi flIC) OU;M"l MS HES(-i I ViR 114 PIT !;•ro - mmy::' 78 201, 21 9.3i r&I i3m),Ek1.6FIELro.Cr; 93306 JVIPI 4. 2012 9: Ila AM BYSTEM r *4':I'POBE OUT IN-Tol'a, . T I :UICEAPO PROBE OUT jwq a . 2r1121 9:33 "-1 1N -TANK. kLARM T 4: PtAe HIr'I.l PPOIA11 - T i4LARM 114-Ti,illi' hLAPH JAN 4. 2012 9 :4'7 mM T .4-.c'urr-R UNLEAMIJ SUI&EN I.6*,:i HI-r;PM JAPI .11 N-121 9: 34 FAI-1 IN -TWO: FiUIPM T 4 :PLUS PROH ou'r III-THM: -L1iP11 JmN a. 120 1 Z, 9: t7 i4m T 3:F;ur.[:p UNI-DifsEr, PROSE OUT JAN 4. !'l 12" 9 ::a4 HM IN-Ti4NK i4l-i4PI-I T 3:SIJPER UNLEADED HIC.'H PROFWT iiL.wPI-i IN-TA10" til.;iRIII jpilq 41 20121 9:49 w"I T 11:PLUS BUI)DEN hl-14-31 JAN 4. 2012, 9 :36 till I N -T MK AI-m?ll - -.- f 3:c;Ul;'EF.' UNLEHIJED PROBE OUT IN -Tw,W ml.oRl'•l ji•11.1 '20 121 9: •19 Hm T 4 : PL U',- PROBE OUT jw4 .1. '201 9; 36 F41 I N Fil-AF.1 I - - - - - T 2 1 01 P-3EL HIC:H WATEP WtAPNIM; IN T,-;NK JAN 4 . ='01 2 51:,19 'im r 2:1.11 CHEL PROBE toUT 114111 4. 201- 9 1 T •I:f'D-6' JiAPI 4 - 20 12 VOLUME . WP ' TER - T I'lV, . 61 9 DES,'- F I Ni-REFASE EIJLI JAN +d - 20 L 2 9:50 W VOLUME WATER 6.1710 TEMP 61 .9 DE,; F I IN TI-411): kL;iF.11 T I WHILEADEt- HIGH PRODUCT HLARVI PAN 1. 2012 9:50 All 11•1-THNK r I : U14LEW)ED H)< PRODUC.,T AL14.'11 JAN 4 , '?01 2 9:'---ri Px,OHE OUT JI-0.) .1 . =U 12 9:50 T 3:,MPEP UNI-EtiEtFli I NVENTORY I l!A.'RLHSF. I PI,:*RDSE fTmRT J14N 4. 9:48 WiLUME 8.101 tJiil*EP = 0.79 1 W.'HES TEHP 62.6 bul; F I PICIPEASE 011.) VOLIAIE 0748 :;iiLS WATER 0.84 INCHES TEMP 62.15 LEC; F GRNT I N,:PD-iSE= 3617 TC* NET ltll.'RE'iSE- 3,16 IN—T41): T -,:roihSEI- Y11CM PRODO-I ALOW1 Jrol 4. 1- 0 12. °.4:50 ;im Pporjuc-r iil-mPM 4. q: S-j fill 2: C, I E.,aEL PPOBE OUT jfiN 4. S-131 2 9: 5"1 HI-I VIE::;; I'lli)p 11.1 PIT STOP MARKET 11101 HlAill, 178 RH):LP`:3FIELD.Ci4 93308 J"N 4. 2012 10:26 N1 T .2': PROBE OUT I'llil.::H MIR I N PIT Mml.'KET 11101 Hl.-Pc 178 jjjjq Ll. -"(J)2 ID:J-j All T '-`:PP08E GOT PRMSURE L1141: LEAK iiLi-IP•I 1, LINE Ft-,IL Lj, 'CJI2 10:41-1 Hj j LINE I.F;if: Al.t4FTI Co Cr.11-iAl 4, ;:01 2, 10:413 All IN-T;41,11' T 2:111ESEL LOSS J;iN 4. 2012 10:11'3 "'I IL I WE LBO: AI.PiRli D :NEGEI. CRC:3:3 Llmr:. FHIL JHPI -1. 2012 10:52, r-V•l 1 >PES*7Uk,E LINE I.Fii' oil.."Pll it 2: 1111 ES'll. F-LLD 8111-ri'll-CNAN AU-411 Ji-,N .1 - 201 ., 10 : 5.:, mm LINF L&if' UrILD-WED C;FUSy LINE FW1. JFAIJ 4. 21012 10:r"? HIII PPE>A)kr. LINE LEFW N.I.IP11 u 3:sora, 1,11•ILLADEL, PLIA, SHUMOWN N.HP1,1 Ji-1111 4. 211)-" 10:1?7 HI-1 PF•S:' ;UkH I,JNE LCHK ml.HRIN ID I i.1 HE PHIL JIAN 4. :LC' 12 1 1: L12 H11 PFFS' ORE L 111 Lrrif' iI.iARjI o I Kill ILHIITI',(A,IN 1-4i"Ilm JI-w I. :.' Lj 12' 11 : (12 I 1ESA [ IiiR I M PIT Sll'ol 11101 HWY ]?a 93:'w6 JA1'1 V) : I.' in GI I LINE FiAlL k) `.HU'rFpDWrJ i-iUAM LINE Fr; IL 2:N-1 D IMUTDOWN t-it-o4d"I QSS LINE FAIL rj:r'LLI) 2Hu*rr1om,i ;-iL#ARPI 4: GROS',-.i L I HE FA I L 1.113&1H rtpip I W PIT STop Pwimp IIIUI HWY 178 Pi-;I*F;,PS*FIEI b,C*o 94306 JAN -1 - 20 12 1 1 : 3.1 ", t'l S1- 1 YITII E;TmUT'. I?EFCRT ,'L r4-L FUNcT I Oltz' 1109.3-1AL I PA/E- lfroPY PEI <)PT T I :1-INLY(ADED 28 17 o4l-S VOLUME . 541 1 L.--', ULLAC,E = w37,i :;iiLS 90% LILLit;E= a576 i:-';ALS D.- VIOLIVIE = 5376 t' ,;LS HE 11.; HT = 50.51 1 fir-11ES WATER VOL - ri CALS LIHTER . 0.110 1 NCHES TDIP . 69 . 1 1. 11 _*., G F T 2: D I 28 17 o4l-S ULIAGE . VOLUME 3441" t:;ALS ULU-iC-E n r.64 90". ULLAC.E 5044 0 G' LS TC VOLUME - 3921 f.ALS HEIGHT - 39. 5t INCHES WATER VOL - 12 GALS L• . 0.77 1 NCHES TEMP . 70. 1) DEC., F T 3: SUPER LINUAlEl'.1 VOLUME . 28 17 o4l-S ULIAGE . 716u 9(Al, LJI-Lmi*;L:- 61 c,9 43441-S TC- VOLLIHE - 2713';, 13o.,I.S, srj. 66 1 NO-IFSJ.66 VOL 0 G' LS WmTER . U. Of's I NO IES TEMP . 71 . C, DEC; )-' r 4 : Puip, VOLUME . 2830 r;tiLS ULL.ol:;E . 7l 55 SIM 6 156 1: L,.-, ri: vouoc z 266'? -, HI -s HE I C.'H,r - 30. 14 C. I NrlIES IthM-*Il`,' VOL 1-1 C;MLS WATER . U. 011 1 PC: I I ES TEMF' . ?1 .5 r-EG F x P* .. 4 1714D - , -z :. SWRCB, January 2006 Spill Bucket Testing Report Form Thisform is intendedfor use by contractors performing annual testing of UST spill containment structures. The completedform and printoutsfrom tests (fapplicable), should be provided to thefacility owner /operatorfor submittal to the local regulatory agency. 1. FACILITY INFORMATION Facility Name: Mesa Marin Food Mart I Date of Testing: 1/4/2012 Facility Address: I 1 101 Highway 178, Bakersfield, CA 93306 Facility Contact: Moe I Phone: 661 - 366 -4886 Date Local Agency Was Notified of Testing: 12/7/2011 Name of Local Agency Inspector (fpresent during testing): Ernie Medina 2. TESTING CONTRACTOR INFORMATION Company Name: Confidence UST Services, Inc. Technician Conducting Test: Bradley Seykora Credentials': X CSLB Contractor X ICC Service Tech. SWRCB Tank Tester Other (Spec) License Number(s): CSLB #804904 ICC # 8111231 3. SPILL BUCKET TESTING INFORMATION Test Method Used: x Hydrostatic Vacuum Other Test Equipment Used: Lake Test Equipment Resolution: .0625" Identify Spill Bucket (By Tank Number, Stored Product, etc. 1 Regular 2 Plus 3 Super 4 Diesel Bucket Installation Type: x Direct Bury Contained in Sump x Direct Bury Contained in Sump x Direct Bury Contained in Sump x Direct Bury Contained in Sum Bucket Diameter: 12.00" 12.00" 12.00" 12.00" Bucket Depth: 15.00" 14.75" 14.00" 14.00" Wait time between applying vacuum /water and start of test: 5 min. 5 min. 5 min. 5 min. Test Start Time (Ti): 9:30 am 9:30 am 9:30 am 9:30 am Initial Reading (111): 8.75" 8.50" 9.00" 9.75" Test End Time (TF): 10:30 am 10:30 am 10:30 am 10:30 am Final Reading (RF): 8.75" 8.50" 9.00" 9.75" Test Duration (TF — Tj): 1 hour 1 hour 1 hour 1 hour Change in Reading (RF - Ri): 0.00" 0.00" 0.00" 0.00" Pass /Fail Threshold or Criteria: 0625" 0625" 0625" 0625" Test Result: X Pass Fail X Pass Fail X Pass Fail X Pass Fail Comments — (include information on repairs made prior to testing, and recommendedfollow -upfor jailed tests) CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING I hereby certify that all the information contained in this reportis true, accurate, and infull compliance with legal requirements. Technician's Signature: Date: 1/4/2012 State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements may be more stringent. 1= Gilbarco EMC 2= Overfill Alarm 3= ESO Switch 4= ATG 5= Regular Turbine 6= Plus Turbind 7= Super Turbine 8= Diesel Turbine 9= Bravo Box 10= PLLD Mesa Main CHevron & Food Mart, 11101 Highway 178 Bakersfield, .CA 93306 1/24/2011 Lj 5,10 8,10 7,10 6,10 O O O4 4O O OO O O O O Regular Fill Diesel Fill Super Fill Plus FillDirectBurialDirectBurialDirectBurialDirectBurial