Loading...
HomeMy WebLinkAbout2011 RESULTSMONITORING SYSTEM CERTIFICATION P0!55 For Use By All Jurisdictions Within the State ofCalifornia Authority Cited: Chapter 6 7, Health and Safety Code; Chapter l6, Division 3, Title 23, California Code ofRegulations This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner /operator. The owner /operator must submit a copy ofthis form to the local agency regulating UST systems within 30 days ofthis date. A. General Information Facility Name: #346 Fastrip #621 Site Address: 805 34th Street Facility Contact Person: Omero Garcia Make /Model of Monitoring System: Gilbarco EMC B. Inventory of Equipment Tested /CertifiedChecktheappropriateboxestoindicatespecificequipmentinspected /wrviced: City: Bakersfield Bldg. No.: Zip: 93301 Contact Phone No.: 661 - 393 -7000 Date of Testing/Servicing: 06/16/2011 Tank ID: 12000 gal. Regular 1 Tank ID: 12000 gal. Regular 2 X] In -Tank Gauging Probe. Model: 847390-107 x] In -Tank Gauging Probe. Model: 847390 -107 Lx] Annular Space or Vault Probe. Model:794390 -420 jx] Annular Space or Vault Sensor. Model: 794390 -420 x] Piping Sump / Trench Sensor(s). Model: 794380-208 x] Piping Sump / Trench Sensor(s). Model: 794380 -208 Fill Sump Sensor(s) Model: Fill Sump Sensor(s). Model: J Mechanical Line Leak Detector. Model:FXIV x] Mechanical Line Leak Detector. Model: FX1V Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: L] Tank Overfill / High Level Sensor. Model: 847390 -107 U Tank Overfill / High Leval Sensor. Model: 847390 -107 Other (specify equip. type and model in Sec. E on Pg. 2) Other (specify equip. type and model in Sec. E on Pg. 2) Tank 1D: 12000 gal. Super Tank ID: 12000 gal. Diesel x] In -Tank Gauging Probe. Mode1:847390 -107 x] In -Tank Gauging Probe. Model: 847390 -107 x] Annular Space or Vault Sensor. Model:Ronan x] Annular Space or Vault Sensor. Model: 794390 -420 X] Piping Sump / Trench Sensor(s). Model:794380 -208 X] Piping Sump / Trench Sensor(s). Model: 794380 -208 Fill Sump Sensors(s). Model: Fill Sump Sensor(s). Model: xx Mechanical Line Leak Decector. Model:FX1V x] Mechanical Line Leak Detector. Model: FXiDV Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: x] Tank Overfill / High Level Sensor. Model: 847390-107 x] Tank Overfill / High Level Sensor. Model: 847390 -107 Other (specify equip. type and model in Sec. E on Pg. 2) Other (specify equip. typs and model in Sec. E on Pg. 2) Dispenser ID: 1 & 2 Dispenser ID: 3&4 R Dispenser Containment Sensor(s). Model: 794380 -208 x] Dispenser Containment Sensor(s). Model: 794380 -208 x] Shear Valve(s). x] Shear Valve(s). Dispenser Containment Float(s) and Chain(s). Dispenser Containment Float(s) and Chain(s) Dispenser ID: 5 & 6 Dispenser ID: 7&8 x] Dispenser Containment Sensor(s). Model: 794380 - 208 x] Dispenser Containment Sensor(s). Model: 794380 -208 x] Shear Valve(s). x] Shear Valve(s). Dispenser Containment Float(s) and Chains(s). Dispenser Containment Float(s) and Chain(s). Dispenser ID: Trans. East Dispenser ID: Trans. West U Dispenser Containment Sensor(s). Model: 794380 -208 U Dispenser Containment Sensor(s). Model: 794380 -208 L] Shear Valve(s). X] Shear Valve(s). Dispenser Containment Float(s) and Chain(s) Dispenser Containment Float(s) and Chain(s). If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. C. Certification - I certify that the equipment identified in this document was inspected /services in accordance with the manufacturers' guidlines. Attached to this Certification is information (e.g. manufacturers' checklist) necessary to varify that this information is correct and a plot plan showing the layout of monitoring equipment. For equipment capable of generating such reports, 1 have attached a copy of the report; (check all that apply) Ex] Syst Set -up U Alarm hist epo. Technician Name (print): Bryan A Self Signature: Certification No: 837501 License No: 804904 Testing Company Name: Confidence UST Services, Inc. Site Address: 805 34th Street, Bakersfield, CA 93301 Phone No: 800- 339 -9930 Date of Testing/Servicing: 06/16/2011 D. Results of Testing /Servicing Software Version Installed: 329.02 Complete the following checklist: x] Yes No* Is the audible alarm operational? x Yes No* Is the Visual alarm operational? x Yes No* Were all sensors visually inspected, functionally tested, and confirmed operational? x Yes No* Were all sensors installed at the lowest point of secondary containment and positioned so that other equipment will not interfere with their proper operation? Lj Yes No* If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) Hx N/A operational? x Yes No* For pressurized piping systems, does the turbine automatically shut down if the piping secondary N/A containment monitoring system detects a leak, fails to operate, or is electrically disconnected? Ifyes: which sensors initate positive shut -down? U Sump/Trench Sensors [x] Dispenser Containment Sensors Did you confirm positive shut -down due to leaks and sensor failure /disconnected? L] Yes; No; X] Yes No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no N/A mechanical overfill prevention valve is installed), is the overfill warning alarm visual and audible at the tank fill point(s) and operating properly? Ifso, at what percent oftank capasity does the alarm trigger? gp % Yes* No Was any momtonng equipment replaced? If Yes, identify specific sensors, pro s, or other equipment replaced and list the manufacturer name and model for all replacement parts in Section E, below. Yes* No Was liquid found inside any secondary containment systems designed as dry systems? Product; Water. Ifyes, describe causes in Section E, below. x N * Was monitoring system set -up reviewed to ensure proper settings? Attach set -up reports, if applicable. Lxj yes No* I Is all monitoring equipment operational per manufacturer's specifications? In Section E below, discribe how and when these deficiencies were or will be corrected. E. Comments: Replaced the light bulb on the Exterior overfill alarm. F. In -Tank Guaging / SIR Equipment: [X] Check this box if tank guaging is used only for inventory control. Check this box if tank guaging or SIR equipment is installed. This section must be completed if in -tank guaging equipment is used to perform leak detection monitoring. Complete the following checklist: Fx] Yes No* Has all input wiring been inspected for proper enter and termination,including testing for ground faults? x Yes No* Were all tank guaging probes visually inspected for damage and residue buildup? x7 Yes 171 No* Was accuracy of system product level readings tested? x Yes No* Was accuracy of system water level readings tested? x Yes 7 No* Were all probes reinstalled properly? U Yes No* Were all items on the equipment manufacturer's maintenance checklist completed? In the Section H, below, describe how and when these deficiencies were or will be corrected. G. Line Leak Detectors (LLD): Check this box if LLD's are not installed. Complete the following checklist: x] Yes No* For equip. start-up or annual equipment certification, was a leak simulated to varify LLD performance? Check all that apply) Simulated leak rate: [X]3 g.p.h.: 0.1 g.p.h.; 0.2 g.p.h.; 7x -yes No* Were all LLD's confirmed operational and accurate within regulatory requirments? x Yes No Was the testing apparatus properly calibrated? Yes No For machamca LLD's, does the LLD restrict product ow it detects a leak? N/A Yes No* For electronic LLD's, does the turbine automatically shut off if the LLD detects a leak? x] N/A Yes No* For electronic LLD's, does the turbine automatically shut off if any portion of the monitoring system is x] N/A disabled or disconnected? Yes No* For electronic LLD's, does the turbine automatically shut off if any portion of the monitoring system U N/A malfunction or fails a test? Yes 7 No* For electronic LLD's, have all accessible wiring connections been visually inspected? X] N/A x Yes No I Were all items on the equipment manufacturer's maintenance checklist completed? In the section H, below, describe how and when these deficiencies were or will be corrected. H. Comments: FASTRIP 346 SYSTEM SETUP 805 34TH COMMUNICATIONS SETUP BAKERSFIELD i :a JUN 16. 2011 8 48 661 -325 -0110 JUN 16. 2011 8:47 AM PORT SETTINGS: SYSTEM UNITS U.S. COMM BOARD : 1 <EDIM ) SYSTEM LANGUAGE RS -232 SECURITY SYSTEM STATUS REPORT ENGLISH CODE : DISABLED SYSTEM DATE:T1ME FORMAT T 3:DELIVERY NEEDED MON DD YYYY HH:MM:SS ,M COMM BOARD 2 IRS -232 BAUD RATE 9600 FASTRIP 346 PARITY NONE INVENTORY REPORT 805 34TH STOP BIT 1 STOP BAKERSFIELD CA DATA LENGTH: 8 DATA 661- 325 -0110 RS -232 :SECURITY T I:UNLEADED VOLUME s I 5_65 ALS SHIFT TIME 1 b:00 All CODE : DISABLED ULLAGE 6797 GGALS SHIFT TIME 2 DISABLED COMM BOARD 3 (RS -232) 90% ULLAGE- 5590 GALS SHIFT TIME 3 DISABLED BAUD RATE 9600 TG VOLUME = 5194 GALS SHIFT TIME 4 DISABLED PARITY NONE HEIGHT = WATER VOL a 50.18 0 INCHES GALS TANK PER TST NEEDED WRN STOP BIT I STOP DATA LENGTH: 8 DATA WATER a 0.00 INCHES DISABLED RS -232 SECURITY TEMP a 79.0 DEC F TANK ANN TST NEEDED WRN CODE : DISABLED DISABLED T 2 :UNLEADED 2 LINE RE- ENABLE METHOD AUTO TRANSMIT SETTINGS: VOLUME 5269 GALS PASS LINE TEST ULILAG•E 90% ULLAGE- 6794 5587 GALS GALS LINE PER TST NEEDED WRN AUTO LEAK ALARM LIMIT DISABLED TC VOLUME = 5196 GALS DISABLED LINE ANN TST NEEDED WRN AUTO HIGH WATER LIMIT DISABLEDHEIGHT = WATER 140L = 50.20 0 INCHES GALS DISABLED AUTO OVERFILL LIMIT WATER = Tp1P a 0.00 79.3 INCHES DEC F PRINT TC VOLUMES AUTOBLOW PRODUCT ENABLED DISABLED AUTO THEFT L 1 IM 1 T T 3:PREMIUII TEMP COMPENSATION DISABLED VOLUME n 1532 GALS VALUE (DEG F ): 60.0 AUTO DELIVERY START ULLAGE a 10530 GALS STICK HEIGHT OFFSET DISABLED 9014 ULLAGE- 9323 GALS DISABLED AUTO DELIVERY END TC VOLUME a 1512 GALS ULLAGE: 90": DISABLED AUTOAUTO EXTERNAL INPUT ONWEIGHT WATER VOL - 24.59 d INCHES GALS DATA FORMAT DISABLED WATER a 0.00 1NCtIES HEIGHT AUTO EXTERNAL INPUT OFF TEMP 78.1 DEG F DAYLIGHT SAVING TIME DISABLED DISABLED AUTO SENSOR FUEL ALARM RE- DIRECT LOCAL PRINTOUT DISABLED T 4:DIESEL DISABLED AUTO SENSOR WATER ALARM VOLUME = ULLA(,E a 2226 9836 GAL...,`' GALS EURO PROTOCOL PREFIX AUTOBSSENSOR OUT ALARM 90% ULLAGE- 8629 GALS S DISABLED TC VOLUME o 2059 GALS HEIGHT - 26.76 INCHES WATER VOL = WATER - = 14 0.90 GALS INCHES SYSTEM SECURITY TEMP a 76.6 DEG F CODE : 000000 MAINTENANCE HISTORY MANIFOLDED TANKS DISABLED END OF MESSAGEINVENTORYTOTALSDISABLEDDISABLEDTI:UNLEADED I T 2: UNLEADED 2 tCHARTSECURITY VOLUME o 10533 GALS SADISABLEDDISABLED TC VOLUME = 10390 GALS NDE * r x } CUSTOM ALARMS DISABLED SERVICE NOTICE DISABLED ISO 3166 COUNTRY CODE: SOFTWARE REVISION LEVEL MASS.-DENSITY VERSION 329.02 DISABLED SOFTWAREP 346329 -100 -C CREATED - 09.07.01.16.29 S- MODULE- 330160 -004 -d SYSTEM FEATURES: PERIODIC IN -TANK TESTS ANNUAL IN -TANK TESTS 1SD IN -TANK SETUP T ]:UNLEADED I PRODUCT CODE i THERMAL COEFF :.000700 TANK DIAMETER : 111.50 TANK PROFILE 1 PT FULL VOL 12062 FLOAT SIZE: 4.0 IN. WATER WAR14I NG 2.0 HIGH WATER LIMIT: 3.0 MAX OR LABEL VOL: 12062 OVERFILL LIMIT 90% 10855 HIGH PRODUCT 95% 11459 DELIVERY LIMIT 1515 1809 LOW PRODUCT : 500 LEAK ALAR11 LIMIT: 99 SUDDEN LOSS LIMIT: 99 TANK TILT 2.50 PROBE OFFSET 0.00 SIPHON MAN I FO]_LED TANKS TO: NONE LINE MANIFOLDED TANKS TO: 02 LEAK MIN PERIODIC: 1% 120 PERIODIC TEST TYPE STANDARD PERIODIC: TEST FAIL ALARM DISABLED GROSS TEST FAIL ALARM DISABLED PER TEST AVERAI 1 NC; : OFF TANK TEST NOTIFY: OFF TNK TST SIPHON BREAK:OFF DELIVERY DELAY I MIN PUMP THRESHOLD 10.00% T 2:UNLEADED 2 PRODUCT CODE 2 THERMAL COEFF :.000700 TANK DIAMETER 111.50 TANK PROFILE 1 PT FULL VOL 12062 FLOAT SIDE: 4.0 IN. WATER WAR14I NG : 2.0 HIGH WATER LIMIT: 3.0 MAX OR LABEL VOL: 12062 OVERFILL LIMIT 10855 HIGH PRODUCT 95516 11459 DELIVERY LIMIT 115% LOW PRODUCT 500 LEAK ALARM LIMIT: 99 SUDDEN LOSS L1111T: 99 TANK TILT 0.00 PROBE OFFSET 0.00 SIPHON MANIFOLDED TANKS Td: NONE LINE MANIFOLDED TANKS TO: 01 LEAK MIN PERIODIC: 1v 120 PERIODIC TEST TYPE STANDARD PERIODIC TEST FAIL ALARM DISABLED GROSS TEST FAIL ALARM DISABLED PER TEST AVERAGINC;: OFF TANK. TEST NOTIFY: OFF TNK TST SIPHON BREAK:OFF DELIVER`! DELAY 1 MIN PUMP THRESHOLD 10.00% T 3 : PP.EM I UM PRODUCT CODE :f THERMAL COEFF :.000700 TANK. DIAMETER 111.50 TANK PROFILE I PT FULL VOL 12062 FLOAT SIZE: 4.0 1r1. WATER WARNING 2.0 HIGH WATER LIMIT: 3.0 MAX OR LABEL VOL: 1 2062 OVERFILL LIMIT 90i 10855 HIGH PRODUCT 95% 11459 DELIVERY LIMIT 15% 1809 LOW PRODUCT 500 LEAK ALARM LIMIT: 99 SUDDEN LOSS LIMIT: 99 TANK TILT 1.40 PROBE OFFSET 0.00 SIPHON MANIFOLDED TANKS Td: NONE LINE 14ANIFOLDED TANKS TO: NONE LEAK MIN PERIODIC: 1% 120 PERIODIC TEST TYPE STANDARD PERIODIC TEST FAIL ALARM DISABLED GROSS TEST FAIL ALARM DISABLED PER TEST AVERAGING: OFF TANK TEST NOTIFY: OFF TNK TST SIPHON BREAK:OFF DELIVERY DELAY 1 MIN PUMP THRESHOLD 10.00% T 4:DIESEL PRODUCT CODE 4 LIQUID SENSOR SETUP PUMP SENSOR SETUP THERMAL C:OEFF :.004500 TANK DIAMETER TANK PROFILE 111.50 I PT L 1:UNL 1 STP S I:UNLEADED I FULL VOL 12062 TRI -STATE SINGLE FLOAT) TANK d: 1CATEGORYSTPSUMPDISPENSEMODE: MANIFOLDED: ALTERNATE FLOAT SIZE: 4.0 IN. L 2:UNL I ANN S 2:PREMIUM WATER WARNING : 2.0 TRI -STATE SINGLE FLOAT) TAW d: 3 HIGH WATER LIMIT: 3.0 CATEGORY ANNULAR SPACE DISPENSE MODE: STANDARD MAX OR LABEL VOL: 12062 OVERFILL LIMIT 90% L 3:UNL 2 STP HIGH PRODUCT 10853 951: TRI -STATE SINGLE FLOAT) 11459 CATEGORY STP SUMP DELIVERY LIMIT 15% 1809 L 4:UNL 2 ANN LOW PRODUCT 500 NORMALLY CLOSED LEA)'. ALARM LIMIT: 99 CATEGORY ANNULAR SPACE SUDAEN LOSS LIMIT: 99 TANK TILT 0.20 OUTPUT RELAY SETUP PROBE OFFSET 0.00 L 5:PREM STP TRI -STATE SINGLE FLOAT) R I:UNL I SIPHON MANIFOLDED TANI'S CATEGORY STP SUMP TYPE: TO: NONE PUMP CONTROL OUTPUT LINE MANIFOLDED TANKS L 6:PREM ANN d: 1 Td: NONE TRI -STATE SINGLE FLOAT) CATEGORY : ANNULAR SPACE LIQUID SENSOR ALMS LEAK, MIN PERIODIC: 19 L (:FUEL ALARM 120 L 3:FUEL ALARM PERIODIC; TEST TYPE L 9 : FUEL ALARM STANDARD L 7:DSL STP LIO:FUEL ALARMTRI -STATE SINGLE FLOAT) L11:FUEL ALARM PERIODIC: TEST FAIL CATEGORY : STP SUMP L12:FUEL ALARM ALARM DISABLED L I:SENSOR OUT ALARM L 3:SENSOR OUT ALARM GROSS TEST FAIL L B:DSL ANN L 9:SENSOR OUT ALARM ALARM DISABLED TRI -STATE SINGLE FLOAT) L10:SENSOR OUT ALARMCATEGORY : ANNULAR SPACE LII:SENSOR OUT ALARM PER TEST AVERAGING: OFF L12:SENSOR OUT ALARM L I:SHORT ALARM TANK TEST NOTIFY: OFF L 9 :DISP 1 2 L 3:SHORT ALARM L 9:SHORT ALARM TNK TST SIPHON BREAK OFF TRI -STATE ISINCLE FLOAT) LIO:SHORT ALARM CATEGORY : DISPENSER PAN LII:SHORT ALARM DELIVERY DELAY I MIN L12:SHORT ALARM PUMP THRESHOLD : 10.000 ISD SITE ALARMS LIO:DISP 3 -4 ISD GROSS PRES FAIL TRI -STATE SINGLE FLOAT) ISD DEGRD PRES FAIL CATEGORY : DISPENSER PAN ISD VAPOR LEAK FAIL IBD VP PRES FAIL ISD VP STATUS FAIL LII:DISP 5 -6 ISD HOSE ALARMS TRI-STATE SINGLE FLOAT) ALL:GROSS COLLECT FAIL CATEGORY : DISPENSER PAN ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL LEAK TEST METHOD TEST ON DATE : ALL TANK JUL 11 2009 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED LEAK TEST REPORT FORMAT NORMAL L12:DISP 7 -8 TRI -STATE (SINGLE FLOAT( CATEGORY : DISPENSER PAN L13 :E TRANS SUMP TRI -STATE (SINGLE FLOAT) CATEGOR`! : PIPING SUI•IP 1-14:14 TRANS SUMP TRI -STATE (SINGLE FLOAT) CATEGORY : PIPING SUMP R 2: UNLD 2 TYPE: R 4:DSL PUMP CONTROL OUTPUT TYPE: TANK d: 2 STANDARD fEVk18D SETUP NORMALLY CLOSED LIQUID SENSOR ALMS TANK. P. NONE L (:FUEL ALARM EVR TYPE: VACUUM ASSIST L 3:FUEL ALARM VACUUM ASSIST TYPE L 9:FUEL ALARM LIQUID SENSOR ALMS HEALY VAC Lt0:FUEL ALARM L 7:FUEL ALARM LII:FUEL ALARM LIO:FUEL ALARM NOZ21-E A ^L RANGE L12:FUEL ALARM L12:FUEL ALARM MAX: 1.15 MIN: 0.95 L 1:SEI480R OUT ALARM L13:FUEL ALARM L 3:SENSOR OUT ALARM L14 :FUEL ALARM VAPOR PROCESSOR TYPE L 9 :SENSOR OUT ALARM L 7 :SENSOR OUT ALARM NONE 1.10:SENSOR OUT ALARM LIO :SENSOR OUT ALARM Ll1:SENSOR OUT ALAR11 L12:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM ANALYSIS TIMES L I :SHORT ALARM L14:SENSOR OUT ALARM TIME: 10:00 AM L 3:SHORT ALARM L 7:SHORT ALARM DELAY MINUTES: 1 L 9:SHORT ALARM LIO:SHORT ALARM LIO :SHORT ALARM L12:SHORT ALARM LII:SHORT ALARM L13 :SHORT ALARM ACCEPT HIGH ORVR: L12:SHORT ALARM L14:SHORT ALARM DISABLED ISD SITE ALARMS R 5:OVERFILL ALARM ISD HOSE TABLE ISD GROSS PRES FAIL TYPE: ID FP FL HL AA RR ISD DEGRD PRES FAIL STANDARD ISD VAPOR LEAK FAIL NORMALLY OPEN 01 01 01 02 01 UU ISD VP PRES FAIL 02 02 02 02 01 UU ISD VP STATUS FAIL TANK 0: NONE 03 03 03 02 02 UU 04 04 04 02 02 UU ISD HOSE ALARMS 05 05 05 02 03 UU ALL:CROSS COLLECT FAIL IN -TANK ALARMS 06 06 06 02 03 UU ALL :DEGRD COLLECT FAIL ALL :OVERFILL ALARM 07 07 07 02 04 UU ALL:FLOW COLLECT FAIL ALL:HIGH PRODUCT ALARM 08 08 08 02 04 UU ALL:MAX PRODUCT ALARM R 3 : PP.E11 TYPE: ISD AIRFLOW METER MAP PUMP CONTROL OUTPUT ID SERIAL NUM LABEL TANK 0: 3 1 8448 FM I -2 2 8409 FM 3 -4 LI+UID SENSOR ALMS 3 8408 FM 5 -6 L 5:FUEL ALARM 4 8455 FM 7 -8 L 9 : FUEL ALAR11 LIO:FUEL ALARM LII:FUEL ALARM ISD FUEL GRADE HOSE MAP L12:FUEL ALARM SMARTSENSOR SETUP 1 2 3 4 L 5:SENSOR OUT ALARM FP MHH MHH MHH MHH AA L 9:SENSOR OUT ALARM LIO:SENSOR OUT ALARM s I:VP 1 -2 01 201 301 901 U U I LII :SENSOR OUT ALARM CATEGORY VAPOR PRESSURE 02 202 302 902 U U I L12:SENSOR OUT ALARM 03 203 303 903 5 U 2 L 5:SHORT ALARM s 2:FM 1 -2 04 2041 304 904 5 U 2 L 9:SHORT ALARM CATEGORY AIR FLOW METER 05 205 305 905 U U 3 LIO :SHORT ALARM 06 206 306 906 U U 3 LII:SHORT ALARM s 3:F11 3 -4 07 207 307 907 5 U 4 L12:9HORT ALARM CATEGORY AIR FLOW METER 08 208 308 908 5 U 4 ISD SITE ALARMS s 4:FM 5 -6 ISD GROSS PRES FAIL CATEGORY AIR FLOW METER LABEL TABLE ISD DEGP.D PRES FAIL I SD VAPOR LEA): FAIL 5 5 : FM 7-8 1: UNASSIGNED ISD VP PRES FAIL CATEGORY AIR FLOW METER' 2: BLENDS ISD VP STATUS FAIL 3: REGULAR 4: MID GRADE ISD HOSE ALARMS 5: PREMIUM ALL:GROS'S COLLECT FAIL 6: BOLD ALL:DEGRD COLLECT FAIL 7: BRONZE ALL :FLOW COLLECT FAIL 6. SILVER 9: BLEND2 10: BLEND4 PMC SETUP PI1C VERSION: 01.02 VAPOR PROCESSOR TYPE. NONE PROCESSOR ':'ONTP.OL LEVEL: NONE x x x x END END * x K X fi x x END A x i X n ALAR11 HISTORY REPORT ALARM HISTORY REPORT IN -TANK ALARM IN -TANK ALARM - - - -- SENSOR ALARM - - - -- IN -TANK ALAR19 T 2: I.INLEADED 2 T 4 : D IESEL T I:UNLEAGEG 1 ALARM HISTORY REPORT OVERFILL ALARM DEC 30. 2010 5: ^4 AM IN -TANK ALARM - - - -- SYSTEM ALARM - - - -- NOV 27. 2010 7:00 AM DELIVERY NEEDED JUN 5, 2011 6:02 AM PAPER OUT NOV 27. 2010 6:36 AM MAY 20. 2011 3:13 PMI MAY 16. 2011 11:52 PM SEP 30. 2010 2:50 P11 MAY 13, 2011 4:57 PMPR114TERERROR A1! DELIVERY NEEDED PROBE OUT MAY 16. 2011 11:52 PM JUN 9. 2011 5:30 P19 DELIVERY NEEDED MAY 22. 2011 10:09 AM JUN 9. 2011 5:33 P19 APR !0, 2011 7:29 PM x x x x END END * x K X fi x x END A x i X n xx. ;i END x;kxx nxxxw END %xx x ALARM HISTORY REPORT ALARM HISTORY REPORT SENSOR ALARM - - - -- IN -TANK ALAR19 L I:UNL 1 STP T I:UNLEAGEG 1 ALARM HISTORY REPORT SPP bump LOW PRODUCT ALARM IN -TANK ALARM - - - -- SEP 30. 2010 2:28 PMI T 3 : PREM I UM INVALID FUEL LEVEL JUN 16. 2011 9:00 AM DELIVERYDELIVERY NEEDEDSEP30. 2010 2:50 P11 14, 2N 1:45 PMSEP30. 2010 11:53 A1! JUN 10. 2011 11:50 AM PROBE OUT JUN 3, =2011 11:04 AM SEP 30. 2010 2 :29 P11 DELIVERY NEEDED JUN 9. 2011 5:33 P19 MAY 22. 2011 10:22 AM APR 10. 2011 7:35 PM x R A END A x A A A ALARM HISTORY REPORT SENSOR ALARM - - - -- L 2:UNL I ANN A14NULAR SPmCE xx. ;i END x;kxx nxxxw END %xx x ALARM HISTORY REPORT ALARM HISTORY REPORT ALARM HISTORY REPORT - - -- SENSOR ALARM - - --- ___ SENSOR ALARM - - - - -- L 6:PREM A1114 L10:DISP 3 -4 L 3:UNL 2 STP SEWOR ALARM - - - -- ANNULAR SPACE DISPENSER PANT STP SUMP FUEL ALARM DEC; 24. 2010 9:37 PM FUEL ALARM DEC 18. 2010 5:05 AM K* K x K END A x x K A ALARn HISTORY REPORT SENSOR ALARM - -- - L 4:UNL 2 ANN ANNULAR SPACE K K ti r K END K x x* x x x x A x END x K* R x * x k a x END K x x K R ALARM HISTORY REPORT ALARM HISTORY REPORT SENSOR ALARM - -- ._ - -- SENSOR (ALARM - -- -- L7:DSL STP LII:DISP 5 -6STPSUMPDISPENSERPAN X h K r x END A k K x Y )e X k x END x X K z* ALARM HISTORY REPORT ALARM HISTORY REPORT SENSOR ALAR11 - - - -- -- SENSOR ALARM - - - -- L 6:DSL ANN 1-12:DISP 7 -8ANNULARSPACEDISPENSERPAN ALARM HISTOR`! REPORT SENSOR ALARM - - - -- L 5:PREM STP r STP SUMP i K K x> END x r x ri x A x h x x E14D X k x k x x x K A A E14D x 4 3 x ALARM HISTORY REPORT SENSOR ALARI'l - -- -- L 9:DISP 1 -2 DISPENSER PAN x x x x x END £ x K x x ALARM HISTORY REPORT SENSOR ALARM - - - -- L13:E TRANS SUMP PIPING SUMP xx:xx END A*Xx;i ALARM HISTORY REPORT SENSOR ALr;Rll ----- L14:14 TRANS SUMP PIPING SUMP w r A END x x)k SENSOR ALARM - - - -- L I: UNL i S"fP STP SUMP FUEL ALARM JUN 16, 2011 9:19 AM SE14SOR ALARM - - - -- L 3: UNL 2 STP STP SUMP FUEL ALARM JUN 16. 2011 9:19 AM SENSOR ALARM - - - -- L 5:PREM STP STP SUMP FUEL ALARM JUN 16, 2011 9:20 All SENSOR ALARM - - - -- L 7:DSL STP STP SUMP FUEL ALARM JUN 16. 2011 9:20 AM SENSOR ALARM - - - -- L 9:DISP 1 -2 DISPENSER PAN FUEL ALARM JUN 16. 2011 9:21 All SE14SOR ALARM - - - -- LIO:DISP 3 -4 DISPENSER PAIN FUEL ALARM JUN 16. 2011 5:22 AM r T I:UNLEADED 1 i NVE14TORY INCREASE INCREASE START JUN 16, 2011 9:20 AM VOLUME . 7884 GALS HEIGHT - 69.34 INCHES WATER . 0.00 INCHES TEMP - 93.7 DEC F INCREASE END JUN 16. 2011 9:22 AM VOLUME - 7980 GALS HEIGHT - 70.06 INCHES WATER - 0.00 INCHES TEMP . 94.0 DEG F GROSS INCREASE- 96 TC NET INCREASE- 92 T 2:UNLEADED 2 1NVENTORY INCREASE INCREASE START JUN 16. 2011 9:20 AM VOLUME - 7804 GALS HEIGHT - 68.74 INCHES WATER - 1.22 INCHES TEMP - 92.9 DEG F INCREASE END JUN 16. 2011 9:22 AM VOLUME s 7806 GALS HEIGHT - 68.75 INCHES WATER - 1.22 INCHES TEMP a 93.0 DEC; F GROSS INCREASE- P TC NET I NC:REASE- I MANIFOLDED TANKS INVENTORY INCREASE T I:UNLEADED I T 2:UNLEADED 2 VOLUME - 98 GALS SENSOR ALARM - - -- LII:DISP 5 -6 DISPENSER PAN FUEL ALARM JUN 16, 2011 9:2^- AM SENSOR ALARM - - - -- L12:DISP 7 -6 DISPENSER PAN FUEL ALARM JUN 16, 2011 9:23 All SENSOR ALARM - - - -- L13:E TRANS SUMP PIPING SUMP FUEL ALARM JUN 16, 2011 9 :24 AM SENSOR ALARM - - - -- L14:W TRANS SUMP PIPING SUMP FUEL ALARM JUN 16. 2011 9:24 AM SENSOR ALARM - - - -- L 2:UNL I ANN ANNULAR SPACE FUEL ALARM JUN 16. 2011 9:25 AM SENSOR ALARM -- - -- L 4:UNL 2 ANN ANNULAR SPACE FUEL ALARM JUN 16. 2011 9:25 AM FASTRIP 346 805 34TH BAKERSFIELD CA 661 - 325 -0110 JUN 16, 2011 9 :27 AM SYSTEM STATUS REPORT ALL FUNCTIONS NORMAL SENSOR ALARM - - - -- L 6:PREM ANN ANNULAR SPACE FUEL ALARM JUN 16, 2011 9:27 AM SENSOR ALARM - - - -- L 8:11SL ANN ANNULAR SPACE FUEL ALARM JUN 16. 2011 9 :26 AM FASTRIP 346 805 34TH BAKERSFIELD CA 661 - 325 -0110 JUN 16. 2011 9:30 AM SYSTEM STATUS REPORT ALL FUNCTIONS NORMAL I14 -TANK ALARM - - - -- T 3:PREMIUM OVERFILL ALARM JUN 16. 2011 9:33 AM IN -TANK ALARM - -- a T 3'. PP.EI,l I UM PROBE OUT JUN 16. 2011 9:34 AM T 4:DIESEL 1 WE14TORY I NCREASE INCREASE START JUN 16, 2011 9:29 AM VOLUME - 8542 GALS HE 1 G14T - 74.33 INCHES WATER - 1.03 INCHES TEMP - 94.3 DEG F INCREASE END JUN 16, 2011 9:34 AM VOLUME - 10635 GALS HEIGHT - 91.90 1NC :HES WATER - 0.80 INCHES TEMP - 95.1 DEG F GROSS INCREASE - 2093 TC NET INCREASE= 1732 IN-TANK ALARM ----- T 3:PREMIUM DELIVERY NEEDED JUN 16. 2011 9:34 AM T 3: PRE11 t UM 114VENTORY 114CREASE INCREASE START JUN 16. 2011 9:33 AM VOLUME a 7428 GALS HEIGHT - 65.95 INCHES WATER - 1.01 INCHES TEMP - 94.1 DEG F INCREASE END JUN 16. 2011 9:35 AM VOLUME - 11002 GALS HEIGHT - 95.54 INCHES WATER - 1.15 INCHES TEMP - 94.3 DEC F GROSS INCREASE- 3574 TC NET INCREASE- 3487 T I : UNLEADED 1 INVENTORY INCREASE IPh:REASE START JUN 16. 2011 9:34 AM VOLUME - 7980 GALS HEIGHT - 70.06 INCHES WATER - 0.00 INCHES TEMP - 95.4 DEC F INCREASE END JUN 16, 2011 9:37 AM VOLUME 7980 GALS HEIGHT 70.06 INCHES WATER 0.00 114CHES TEMP 95.6 DEC F GROSS I WREASEa 0 TC NET INCREASE= -1 T 2:UNLEADED 2 INVENTORY INCREASE INCREASE START JUN 16. 2011 9:34 AM VOLUME - 7805 GALS HEIGHT - 68.75 INCHES WATER - 1.22 INCHESTEMP - 94.7 DEC F INCREASE END JUN 16. 2011 9:37 AM VOLUME - 10653 GALS HEIGHT - 92.07 INCHES WATER - 0.00 1WHES TEMP - 94.8 DEG F i.,ROSS INCREASE- 2848 TC NET INCREASE- 2777 MANIFOLDED TANKS INVENTORY INCREASE T I:UNLEADED 1 T 2:UNLEADED 2 VOLUME - 2848 GALS FA.STR 1 P 346 805 34TH BAKERSF I ELI: C:A 661 -325 -0110 JUN 16, 2011 9 :37 AM S'fSTEM STATUS REPORT T 3 :LIVERY NEEDEDDE IN -TANK ALARM - - - -- T 2:UNLEADED 2 OVERFILL ALARM JUN 16. 2011 9:39 AM IN -TANK ALARM T 2 :UNLEADE6 2 PROBE OUT JUN 16. 2011 9:39 AM IN -TANK ALARM - - - -- T 2:UNLEADED 2 LOW TEMP WARNING JUN 16, 2011 9:40 AM s T I:UNLEADED I INVENTORY INCREASE INCREASE START JUN 16, 2011 9:38 AM VOLUME - 7960 GALS HEIGHT - 70.06 INCHES WATER - 0.00 INt'HES TEMP - 96.0 DE F INCREASE END JUN 16. '?Olf 9:40 AM VOLUME - 7980 GALS HEIGHT - 70.06 INCHES WATER - 0.00 INCHES TEMP 0 96.2 DEC F GROSS INCREASE- 0 TC NET INCREASE- -1 T 2:UNLEADED 2 1NVENTORY INCREASE INCREASE START JUN 16. 2011 9 :38 AM VOLUME - 5940 GALS HEIGHT - 55.09 INCHES WATER - 0.00 INCHES TEMP - 95.4 DEG F INCREASE END JUN 16. 2011 9:40 AM VOLUME - 10852 GALS HEIGHT - 94.01 114CHES WATER - 0.00 INCHES TEMP - 95.2 DEG F GROSS INCREASE- 4912 TC NET INCREASE - 4792 MANIFOLDED TANKS INVENTORY INCREASE T I :UNLEADED 1 T 2:UNLEADED 2 VOLUME - 4912 GALS FASTRIP 346 - - -- IN -TANK ALAR11 - - - -- - - -- IN -TANK ALARM - -- -- 805 34TH T 4:DIESEL T 4:DIESELBAKERSFIELDCAINVALIDFUELLEVELDELIVERYNEEDED661 -325 -0110 JUN 16. 2011 9:44 AM JUN 16, 2011 9:45 AM JUN 16. 2011 1):41 AM SYSTEM STATUS REPORT T 2:LOW TEMP WARNING T 3:DELIVERY NEEDED IN -TANK ALARM -•• - -- T I:UNLEADED I OVERFILL ALARM JUN 16. 2011 9:42 AM IN -TAN), ALARM - - - -- T I:UNLEADED IPROBEOUT JUN 16. 2011 9:43 Ahl IN -TANK ALARM - - - -- T I:UNLEADED 1 LOW TEMP WARNING JUN 16. 2011 9:43 NM IN -TANK ALARM - - - -- T 4:DIESEL OVERFILL ALARM JUN 16. 2011 9:44 AM 1N-TANK ALARM - - - -- T-4:DIESEL PROBE OUT JUN 16. 2011 9:44 AI T I:UNLEADED I INVENTORY INCREASE INCREASE START JUN 16. 2011 9:43 AM VOLUME - 0 GALS HEIGHT m 0.00 INCHES WATER - 0.00 INCHES TEMP 0.0 DEG F INCREASE END JUN 16, 2011 9:45 AM VOLUME v 11007 GALS HEIGHT - 95.59 INCHES WATER a 0.00 INCHES TEMP - 96.4 DEG F GR08S INCREASE- 11007 TC NET INCREASE- 10726 T 2:UNLEADED 2 INVENTORY INCREASE INCREASE START JUN 16. 2011 9:43 AM VOLUME e 5280 GALS HEIGHT a 50.29 INCHES WATER a 0.77 INCHES TEMP = 86.7 DEG F INCREASE END JUN 16. 2011 9:45 AM VOLUME D 5278 GALS HEIGHT - 50.28 INCHES WATER o 0.77 INCHES TEMP - 87.4 DEG F GROSS l NCCEASE- -2 TC NET INCREASE- -3 MANIFOLDED TANKS INVENTORY INCREASE T (:UNLEADED 1 T 2:UNLEADED 2 VOLUME - 11007 CALS T 4:DIESEL INVENTORY INCREASE INCREASE START JUN 16, 2011 9:43 AM VOLUME a 6622 GALS HEIGHT a 60.04 INCHES WATER . 0.00 INCHES TEMP a 97.4 DEG, F INCREASE END JUN 16. 2011 9:46 AM VOLUME o 10941 GALS HEIGHT a 94.91 INCHES WATER . 1.11 INCHES TEMP . 97.1 DEG F GROSS INCREASEv 4319 TC NET INCREASE- 3610 SEICOR ALAR11 LII:DISP 5 -6 DISPENSER PAN SENSOR OUT ALARM JUN 16. 2'011 9:47 AM y - - - -- SENSOR ALARM - - - -- L 9:DISP 1 -2 DISPENSER PAN SENSOR OUT ALARM JUN 16, 2011 9:47 All SENSOR ALARM - - - -- L12:DISP 7 -8 DISPENSER PAN SENSOR OUT ALARM JUN 16. 2011 9:47 AM SENSOR ALARM - -- -- L13:E TRANS SUMP PIPING SUMP SENSOR OUT ALARM JUN 16. 2011 9:47 AM SENSOR ALARM - - - -- LID:DISP 3 -4 DISPENSER PAN SENSOR OUT ALARM JUN 16, 2011 9:47 All SENSOR ALARM - - - -- L14:W TRANS SUMP PIP114G SUMP SENSOR OUT ALARM JUN 16. 2011 9:47 All SENSOR ALARM - - - -- L 3:UNL 2 STP STP SUMP SENSOR OUT ALARM JUN 16. 2011 9:47 AM SENSOR ALARM - - - -- L 4:UNL 2 ANN ANNULAR SPACE FUEL ALARM JUN 16. 2011 9:47 AM SENSOR. ALARM - - - -- L 5:PREM STP STP SUMP SENSOR OUT ALARM JUN 16, 2011 9:47 AM SENSOR ALARM - - - -- L 7:DSL STP STP SUMP SENSOR OUT ALARM JUN 16. 2011 9 :47 14.1 SENSOR ALARM - - --- L 1:UNL I STP STP SUMP SENSOR OUT ALARM JUN 16. 2011 9:47 AM SENSOR ALARM - - - -- L 6:PREM ANN ANNULAR SPACE SENSOR OUT ALARM JUN 16, 2011 9:47 All SENSOR ALARM - - - -- L 9:DSL ANN ANNULAR SPACE SENSOR OUT ALARM JUN 16. 2011 9:47 AM SENSOR ALARM - -- -- L 2:UNL 1 ANN ANNULAR SPACE SENSOR OUT ALARM JUN 16. 2011 9:47 AM 6 FASTRIP 346 605 34TH BAKERSFIELD CA 661- 325-0110 JUN lb. 2011 9:49 kM SYSTEM STATUS REPORT T 3:DELIVERY NEEDED L 2:SENSOR OUT ALARM L 3:SENSOR OUT ALARM L 4:FUEL ALARM L 5:SENSOR OUT ALkRM L 6:SENSOR OUT ALARM L 7:SENSOR OUT ALARM L 8:SENSOR OUT ALARM ARCHIVE UTILITY SAVE SETUP DATA: START TIME: JUN 16. 2011 9:49:21 AM ARCHIVE UTILITY SAVE SETUP DATA: END TIME: JUN 16. 2011 9:50:51 All BYTES : 19200 SWRCB, January 2006 Spill Bucket Testing Report Form Thisform is intendedfor use by contractors performing annual testing of UST spill containment structures. The completedform and printoutsfrom tests (fapplicable), should be provided to thefacility owner /operatorfor submittal to the local regulatory agency. 1. FACILITY INFORMATION Facility Name: #346 Fastrip #621 Date ofTesting: 06/16/2011 Facility Address: 805 34` Street, Bakersfield, CA 93301 Facility Contact: Omero Garcia Phone: 661 - 393 -7000 Date Local Agency Was Notified of Testing: Name of Local Agency Inspector (c(present during testing): Ernie Medina 2. TESTING CONTRACTOR INFORMATION Company Name: Confidence UST Services, Inc. Technician Conducting Test: Bryan A Self Credentials: X CSLB Contractor X ICC Service Tech. X SWRCB Tank Tester Other (Spec) License Number(s): CSLB #804904 ICC #8022804 -UT Tank Tester 11 -1756 3. SPILL BUCKET TESTING INFORMATION Test Method Used: x Hydrostatic Vacuum Other Test Equipment Used: Lake Test Equipment Resolution: 0.0625" Identify Spill Bucket (By Tank Number, Stored Product, etc.) 1 Regular 1 2 Regular 2 3 Super 4 Diesel Bucket Installation Type: Direct Bury x Contained in Sump Direct Bury x Contained in Sump Direct Bury x Contained in Sump Direct Bury x Contained in Sum Bucket Diameter: 12.00" 12.00" 12.00" 12.00" Bucket Depth: 14.25" 14.50" 13.75" 14.00" Wait time between applying vacuum /water and start of test: 5 min. 5 min. 5 min. 5 min. Test Start Time (Ti): 9:00 am 9:00 am 9:00 am 9:00 am Initial Reading (Ri): 10.00" 9.75" 10.00" 10.25" Test End Time (TF): 10:00 am 10:00 am 10:00 am 10:00 am Final Reading (RF): 10.00" 9.75" 10.00" 10.25" Test Duration (TF — Ti): 1 hour 1 hour 1 hour I hour Change in Reading (RF - Rj): 0.00" 0.00" 0.00" 0.00" Pass/Fail Threshold or Criteria: 0.0625" 0.0625" 0.0625" 0.0625 Test Result: X Pass Fail X Pass Fail X Pass Fail X Pass Fail Comments — (include information on repairs made prior to testing, and recommendedfollow -upforfailed tests) CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING I hereby certify that all the information contained in this report is trug, accurate, and in full compliance with legal requirements. Technician's Signature' Date: 06/16/2011 State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements may be more stringent.