HomeMy WebLinkAboutINSPECTION REPORT 2014Underground Storage Tank Pr ram DW Inspection Report ' Permission to Inspect: BAKERSFIELD FIRE DEPARTMENT Prevention Services Division 2101 H Street Bakersfield, CA 93301 Phone: 661 - 326 -3979 Fax: 661 -852 -2171 Business Name: HUNGRY'S MARKET -15- 021 - 000443 Date: 10/3012014 Address Name: 3711 Mount Vernon Ave- Inspector Name: Shane Gardner #8248557 Inspection Type: Routine Report: Final NVO = No Violation Observed OUT = Out of Compliance NA = Not Applicable UD = Undetermined COS = Corrected On Site RPT = Repeat Violation Violation Program Requirement d o SOC Comments No > > Q G O a 030 z O z n 0 W 05 File Review Facility Tank Information 2030021 Facility has a valid Permit Tank 1- 10000- SW -REG to Operate from the Tank 2- 10000- SW -PRM CUPA - 23 CCR 16 2712(1); ❑ ❑ ❑ ❑ ❑ None Tank 3- 10000- SW -DSL HSC 6.7 25284 Tank 4- 2010010 UST Operating Permit Application for Facility information and Tank information ❑ ❑ ❑ ❑ ❑ None submitted /maintained - 23 CCR 16 2711; HSC 6.7 25286(a) 2010001 Current BOE number submitted to the CUPA ❑ ❑ ❑ ❑ E] None and /or CERS - HSC 6.7 25286(c) 2030011 UST compliance statement and /or Designated Operator n ❑ ❑ ❑ ❑ ❑ None current certification submitted - 23 CCR 16 2715(a), 2715(b 2030046 A complete and accurate response plan has been submitted, approved and r7l ❑ ❑ ❑ ❑ ❑ None maintained - 23 CCR 16 2632, 2634(e), 2641(h), 2712(i) 2030041 A complete and accurate plot plan has been submitted, approved and ❑ ❑ ❑ ❑ ❑ None maintained - 23 CCR 16 2632 d 1 C), 2711 a (8 2010006 Owner /Operator has not made false statements or representation on any ❑ ❑ ❑ ❑ ❑ None required document - HSC 6.7 25299 2010003 Owner /Operator has a DO and /or informed the CUPA of any change (s) ❑ ❑ ❑ ❑ ❑ None within 30 days - 23 CCR 16 2715(a) Violation Program Requirement 4- 0 SOC Comments No 0 CO 0 a. 030 Z 0 z M 0 W Testing 2030002 Owner/Operator has tested and certified leak None detection equipment Zvi annually - 23 CCR 16 2638 2030048 Secondary containment testing conducted every 36 months in accordance P" ❑ ❑ ❑ ❑ ❑ None with requirements - 23 CCR 16 2637 2030055 Spill buckets have been /a, I r,- \D tested annually as 1:1 ❑ ❑ None required - HSC 6.7 25284.2 2010009 Secondary containment test results submitted to the CUPA within 30 days None after the test - 23 CCR 16 2637(e) 2030064 CUPA was poperly notified within the prescribed number of ❑ ❑ ❑ ❑ R None hours prior to testing - 23 CCR 16 26370, 2638(e), 2643(g), 2644.1(a)(4) Install/Repair 2060009 Permits obtained to install, replace, repair, or F1 R ❑ L ❑ ❑ None modify part of the UST system - 23 CCR 16 2712 -A LIST System Observation General Monitoring 2030003 Leak detection system maintains continuous RD monitoring that activates None ❑ an audible and visual Yes alarm - 23 CCR 16 2632, 2634, 2636, 2666 2030016 The annular space of the tank, piping and sumps RD are continuously monitored and activates El R ❑ None [:1 the alarm - 23 CCR 16 Yes 2631(8), 2632(c)(2)(A)&(B), 2633 c , 2636(o 2030017 Product piping outside the UDC is fail-safe and shuts down the pump or ❑ ❑ ❑ ❑ ❑ None restricts flow - 23 CCR 16 2636(0(5) 2030018 Turbine sump monitor RD activates an audible and visual alarm or stops the ❑ ❑ ❑ None ❑ flow of at the dispenser - Yes 23 CCR 16 26360(1) 1 1 1 1 Underground Storage Tank Program - DW Inspection Report v 2.0 Violation Program Requirement a o SOC Comments No OO D Q p p a �o z O z f 2030019 Monitoring system in the UDCs activates an audible and visual alarm ❑ ❑ ❑ ❑ ❑ None or stops the flow at the UDC -23 CCR 16 2636 (0(1) 2030043 Leak detection equipment properly programmed or , RD properly operated - 23 ❑ ❑ ❑ ❑ ❑ None ❑ CCR 16 2632, 2634, 2636, Yes 2666 2060005 System constructed with a monitoring system capable of detecting entry ❑ ❑ ❑ ❑ ❑ None into secondary fi containment - HSC 6.7 25291(b) 2060014 Correct leak detection equipment installed for RD the type of system ❑ ❑ El ❑ ❑ None ❑ present - 23 CCR 16 2638; Yes HSC 6.7 25290.1, 25290.2, 25291 2060015 Sensor located in the RD proper position /location - A ❑ ❑ ❑ ❑ ❑ None ❑ 23 CCR 16 2630(d), 2641(a) Yes 2030062 Facility is in compliance with not tampering with or RD disabling leak detection ( ❑ ❑ ❑ ❑ ❑ None ❑ devices or alarms - HSC Yes 6.7 25299 a 9 2060022 System constructed with a monitoring system capable of detecting entry ❑ ❑ ❑ ❑ None into secondary containment - HSC 6.7 25290.2(d) 2030034 Tag /sticker on affixed monitoring equipment being certified, repaired, � ❑ ❑ F] ❑ F1 None or replaced - 23 CCR 16 2638 VPH Monitoring VPH 2030065 Interstitial monitoring of the annular spaces of the RD UST is properly ❑ ❑ ❑ ❑ ❑ None ❑ maintained - HSC 6.7 Yes 25290.1 e 2060023 System constructed with a monitoring system capable of detecting entry into secondary ❑ ❑ ❑ ❑ ❑ None containment - HSC 6.7 25290.1(d) Underground Storage Tank Program - DW Inspection Report v 2.0 Violation Program Requirement 4- 0 SOC Comments No C) cr) 0 CL 0 Z 0 Z Line Leak Detector 2060012 Line leak detector installed on pressurized A RD piping system - HSC 6.7 ❑ None ❑ 25290. 1 (h), 25290.2(g), Yes 252910, 25292(e), 2636(0(2) 2030026 Line leak detectors detect a 3 gph leak and/or RD audible and visual alarm None function properly - 23 CCR 16 2636(0(6), es 2666(c) 2030027 Turbine shuts down when a leak is detected or RD -tor is when line leak detector None ❑ disconnected - 23 CCR 16 Yes 2666 2030025 Pressurized piping able to detect a 3.0 gph leak RD within an hour, and ❑ None ❑ restricts the flow or Yes alarms - 23 CCR 16 2636(0(2) Secondary Containment 2060010 UST storing a hazardous RD substance has secondary None ❑ containment - HSC 6.7 Yes 25292 Underground Storage Tank Program - DW Inspection Report v 2.0 Violation Program Requirement 4- 0 .2 w S-- 0C Comments No >0 a 0 (L 12% 1 0 Z 01 Z =1 0 W1 2030008 UDC, sumps, and/or other secondary containment in good ❑ ❑ ❑ ❑ ❑ None condition and/or are free of debris/liquid - HSC 6.7 25290.1, 25290.2, 25291 2030040 Secondarily contained RD piping maintained to allow None [:1 liquid to drain into sump - Yes 23 CCR 16 2630(d), 2641 (a) 2060006 Secondary containment piping slopes back to the jZf ❑ ❑ ❑ ❑ ❑ None collection sump - 23 CCR 16 263(c) 2030047 Secondary containment maintained tight and has been confirmed by testing ❑ 1:1 ❑ ❑ ❑ None - 23 CCR 16 2662, HSC 6.7 ZZ 25290.1(c)(2), 25290.2(c)(2), 25291 a ), 25292(e) 2030060 Entry fittings in secondary containment for UST system maintained None tight/sealed - 23 CCR 16 2630, 2635(d), 2636(c), 2666 2060020 Spill bucket is installed RP and has a functional drain valve or other means to ❑ None ❑ remove liquid - 23 CCR 16 Yes 2635(b), 2665 2030054 Spill bucket maintained in RP good condition and free of ❑ 1:1 ❑ None ❑ debris and/or liquid - 23 Yes CCR 16 2635(b), 2715(c)(2) 2060019 Spill bucket to has a minimum capacity of five None gallons - 23 CCR 16 2635(b), 2665 Overfill 2030035 UST system is operated to prevent unauthorized RP release, including spills ❑ F-1 None F-1 and overfills - HSC 6.7 Yes 25292.1 (a) 2030036 Overfill prevention system RP has not been overridden and meets overfill None r-1 requirements - 23 CCR 16 Yes 2635(b)(2), 2665 Underground Storage Tank Program - DW Inspection Report v 2.0 Violation Program Requirement 0 0.0 SOC Comments No 0 0 a. 0 z 0 z On Site Records Certifications 2030023 Required designated operators or contractors maintain a proper and None current ICC certification - 23 CCR 16 2715 2030024 Service technician, installer, and/ or employee maintain a None proper license - 23 CCR 162715 2030031 Employee or contractor obtained and maintained proper manufacturer ❑ ❑ ❑ None certification - 23 CCR 16 2715 2010007 Submit/maintain current Certificate of Financial Responsibility/mechanism of financial assurance - XE] None 23 CCR 16 2711; 23 CCR 18 2808.1, 2809-2809.2, HSC 6.7 25292.2; HSC 6.75 25299.30-25299.34 Designated Operator 2010004 Copies of DO inspections for last 12 months and list of trained employees None maintained - 23 CCR 16 2715 2030013 Designated operator properly conducted the monthly inspection and EJ"" ❑ ❑ ❑ ❑ ❑ None the reports are complete - 23 CCR 16 2715 2030010 DO notified operator of any condition observed- during the monthly ❑ ❑ ❑ ❑ ❑ None inspection that may require action - 23 CCR 16 2715(A 2030012 DO employee training performed, current for at least one employee on None site, and a log kept - 23 CCR 16 2715(c)(6), 27150 Underground Storage Tank Program - DW Inspection Report v 2.0 Violation Program Requirement %I- 0 .2 9 SOC Comments No O 0 (0 0 0. IT O)o Z 0 Z M 0 W Logs 2030001 Leak detection alarm logs, maintenance and RD records of appropriate P' ❑ EIn ❑ ❑ None ❑ follow-up actions Yes maintained - 23 CCR 16 2632, 2634, 2712(b) Maintenance/Tests 2010008 Monitoring, maintenance, repairs, linings, and RD upgrade records ❑ ❑ ❑ ❑ ❑ None ❑ maintained for the proper Yes time period - 23 CCR 16 2712(b) Documentation 2030033 Failure to maintain on site an approved monitoring n ❑ ❑ ❑ r-1 None plan - 23 CCR 16 2632, 2634, 2711, 2712(1) 2030037 Written agreement between the tank owner and tank operator to monitor the tank system None is maintained - 23 CCR 16 2620(b); HSC 6.7 25284(a)(3) 2030061 Suspected or actual RD unauthorized release reported in appropriate ❑ ❑ ❑ None ❑ time frame - HSC 6.7 Yes 29294,29295 -A General Operating Requirements Permit Condition/Approval 2030039 Compliance with all operating permit None conditions - 23 CCR 16 2712, HSC 6.7 25299 2030059 UST system maintained in accordance with exclusion/exemption ❑ ❑ None status - HSC 6.7 25281.6, 25283.5 2030014 Owner/Operator received approval and has implemented a training ❑ ❑ None program at an unstaffed facility - 23 CCR 16 2715( (2 2030015 Facility exhibited that the method used to monitor the tank meets the monitoring methods in None 2643(f) - 23 CCR 16 2643 Underground Storage Tank Program - DW Inspection Report v 2.0 Violation Program Requirement o SOC Comments No M ,� o p a �o z O z M V W o> Red Tag 2030045 Red Tag information is legible and has not been ❑ ❑ ❑ ❑ ❑ None tampered with - 23 CCR '0' 16 2717.1 2030044 Facility did not allow for deposit of petroleum into a UST that has a red tag ❑ ❑ ❑ ❑ ❑ None affixed to the fill - 23 CCR 16 2717.1 Install /Repair 2060024 UST system is made of or lined with materials that are compatible with the ❑ ❑ ❑ ❑ ❑ None substance stored - 23 CCR 16 2631.1 2060021 Striker plate installed and positioned correctly - 23 [ ❑ ❑ ❑ ❑ ❑ None CCR 16 2631 c , 2662(d) ❑ There were no violations noted for this inspection. report shall serve as a "NOTICE TO COMPLY" for Minor Violations, and a "NOTICE OF VIOLATION" for Major violations. You are, hereby, ordered to correct the above noted violations within 30 days, or according to correction summaries provided. Formal enforcement and /or penalty assessment may be initiated for any violations noted, and for those not corrected in a timely manner. (NOTE: If this is a preliminary report, a final report will follow.) Operator Name: Date: ICC# Inspectors Signature: Title: Date: 2/ 4 So l 7" Inspector: Enter # of Violations: RD: k _ RP: Check one box for facility Significant Operational Status (SOC) to be reported to SWRCB and US EPA: ❑ SOC with both Release Detection and Release Detection (Facility has no Release Prevention and no Release Prevention Violations) ❑ Not in SOC (Facility has both Release Prevention and Release Detection Violations) ❑SOC with Release Detection only (Facility has no Release Detection violations but one or more Release Prevention vio tions) V�w�ith Release Prevention only (Facility has no Release Prevention violations but one o re Release Detection Underground Storage Tank Program - DW Inspection Report v 2.0