Loading...
HomeMy WebLinkAboutNOTICE OF INTENTNATURAL RESOURCES AGENCY OF CALIFORNIA DEPARTMENT OF CONSERVATION DIVISION OF OiL, GAS, AND GEOTHERMAL RESOURCES FOR DIVISION USE ONLY Bond Forms TOP OGD114 OGD121 FORMATION PRESSURE (Estimated Maximum) CALCULATED FILL BEHIND CASING (Linear Feet) 160 %0 Wall NOTICE OF INTENTION TO DRILL NEW WELL Detailed instructions can be found at: vv%,rw_conservation ca.gov/d compliance with Section 3203, Division 3, Public Resources Code, notice is hereby given that it is our intention to drill well Red Ribbon Ranch #87 , well type Sec. 27 , T. 29S , R. 27E , MD B.&M., Fruitvale Cell Field, API No. , (Assigned by Division) Kern County. Legal description of mineral -right lease, consisting of 300 acres (attach map or plat to scale), is as follows: Lots 1, S, 9, 14, 16, 17, 18, 19, 22, 23, 24, 25, 26,&27 in Sec 27, except the W. 24 acres of lot 27 and E/2 of lot 1 Do mineral and surface leases coincide? Yes® No []. If answer is no, attach legal description of both surface and mineral leases, and map or plat to scale. Location of well 1265 feet South along section ® / property [1 line and 125( Direction (Check one) at right angles to said line from the Northeast corner of section [@ I property ❑ (Check one) !_at.lLona_ in decimal dearees_ to six decimal places. NAD 83 format: Latitude: 35.3797990 feet West (Direction) 27 and Longitude., - 119.0606800 If well is to be directionally drilled, show proposed coordinates (from surface location) and true vertical depth at total depth: - feet - and - feet - . Estimated true vertical depth 4500' Elevation of ground (Direction) (Direction) above sea level 401 feet. All depth measurements taken from top of Kelly Bushing that is 14 feet above ground. (Derrick Floor, Rotary Table, or Kegy Bushing) Is this a critical well as defined in the California Code of Regulations, Title 14, Section 1720(a) (see next page)? Yes[] No® Is a California Environmental Quality Act (CEQA) document required by a local agency? Yes[] No® If yes, see next page. PROPOSED CASING PROGRAM SIZE OF CASING (Incites API} WEIGHT GRADE AND TYPE TOP BOTTOM CEMENTING DEPTHS FORMATION PRESSURE (Estimated Maximum) CALCULATED FILL BEHIND CASING (Linear Feet) 160 %0 Wall Conductor 0' 54' 54' NA 54' 9-5180 36# K-65, BTC 0' 500' 500' 500' 5-120 15.5# K-55, LTC 0' 4500' 3550' ±1300 psi 3550' (Attach a complete drilling program Including wellbore schematics in addition to the above casing program.) Estimated depth of base of fresh water: 3000' Anticipated geological markers: Chanac 3360'TVD, Martin 3550'TVD (Name, dertfi) Intended zone(s) of completion: Kernco, 3360' TVD, 11300 psi Estimated total depth: 4500' (Name, depth and expected pressure) The Division must be notified immediately of changes to the proposed operations. Failure to provide a true and accurate representation of the well and proposed operations may cause rescission of the permit. Name of Operator San Joaquin Facilities Management Address 4520 California Ave, Suite 300 City /State Bakersfield, CA Zip Code 93309 Name of Person Filing Notice Telephone Number: Signature Date Tim Spriet (661) 337 -9770 ginwffu, aq sp %id 7/25/14 Individual to contact for technical questions: Telephone Number: E -Mail Address: Tim Spriet (661) 337 -9770 tim.spriet@driltek.com This notice and an indemnity or cash bond shall be filed, and approval given, before drilling begins. If operations have not commenced within one year of the Division's receipt of the notice, this notice will be considered cancelled. 00105 (W09)