HomeMy WebLinkAboutNOTICE OF INTENTNATURAL RESOURCES AGENCY OF CALIFORNIA
DEPARTMENT OF CONSERVATION
DIVISION OF OiL, GAS, AND GEOTHERMAL RESOURCES
FOR DIVISION USE ONLY
Bond
Forms
TOP
OGD114
OGD121
FORMATION
PRESSURE
(Estimated Maximum)
CALCULATED FILL BEHIND
CASING (Linear Feet)
160
%0 Wall
NOTICE OF INTENTION TO DRILL NEW WELL
Detailed instructions can be found at: vv%,rw_conservation ca.gov/d
compliance with Section 3203, Division 3, Public Resources Code, notice is hereby given that it is our intention to drill
well Red Ribbon Ranch #87 , well type
Sec. 27 , T. 29S , R. 27E , MD B.&M.,
Fruitvale
Cell
Field,
API No. ,
(Assigned by Division)
Kern County.
Legal description of mineral -right lease, consisting of 300 acres (attach map or plat to scale), is as follows:
Lots 1, S, 9, 14, 16, 17, 18, 19, 22, 23, 24, 25, 26,&27 in Sec 27, except the W. 24 acres of lot 27 and E/2 of lot 1
Do mineral and surface leases coincide? Yes® No []. If answer is no, attach legal description of both surface and mineral leases,
and map or plat to scale.
Location of well 1265 feet South along section ® / property [1 line and 125(
Direction (Check one)
at right angles to said line from the Northeast corner of section [@ I property ❑
(Check one)
!_at.lLona_ in decimal dearees_ to six decimal places. NAD 83 format: Latitude: 35.3797990
feet West
(Direction)
27 and
Longitude., - 119.0606800
If well is to be directionally drilled, show proposed coordinates (from surface location) and true vertical depth at total depth:
- feet - and - feet - . Estimated true vertical depth 4500' Elevation of ground
(Direction) (Direction)
above sea level 401 feet. All depth measurements taken from top of Kelly Bushing that is 14 feet above ground.
(Derrick Floor, Rotary Table, or Kegy Bushing)
Is this a critical well as defined in the California Code of Regulations, Title 14, Section 1720(a) (see next page)? Yes[] No®
Is a California Environmental Quality Act (CEQA) document required by a local agency? Yes[] No® If yes, see next page.
PROPOSED CASING PROGRAM
SIZE OF
CASING
(Incites API}
WEIGHT
GRADE AND
TYPE
TOP
BOTTOM
CEMENTING
DEPTHS
FORMATION
PRESSURE
(Estimated Maximum)
CALCULATED FILL BEHIND
CASING (Linear Feet)
160
%0 Wall
Conductor
0'
54'
54'
NA
54'
9-5180
36#
K-65, BTC
0'
500'
500'
500'
5-120
15.5#
K-55, LTC
0'
4500'
3550'
±1300 psi
3550'
(Attach a complete drilling program Including wellbore schematics in addition to the above casing program.)
Estimated depth of base of fresh water: 3000' Anticipated geological markers: Chanac 3360'TVD, Martin 3550'TVD
(Name, dertfi)
Intended zone(s) of completion: Kernco, 3360' TVD, 11300 psi Estimated total depth: 4500'
(Name, depth and expected pressure)
The Division must be notified immediately of changes to the proposed operations. Failure to provide a true and accurate
representation of the well and proposed operations may cause rescission of the permit.
Name of Operator
San Joaquin Facilities Management
Address
4520 California Ave, Suite 300
City /State
Bakersfield, CA
Zip Code
93309
Name of Person Filing Notice
Telephone Number:
Signature
Date
Tim Spriet
(661) 337 -9770
ginwffu, aq sp %id
7/25/14
Individual to contact for technical questions:
Telephone Number:
E -Mail Address:
Tim Spriet
(661) 337 -9770
tim.spriet@driltek.com
This notice and an indemnity or cash bond shall be filed, and approval given, before drilling begins. If operations have not
commenced within one year of the Division's receipt of the notice, this notice will be considered cancelled.
00105 (W09)