Loading...
HomeMy WebLinkAboutNOTICE OF INTENTF Bond 0GD1 1 4 FOR ISION USE ONLY NATURAL RESOURCES AGENCY OF CALIFORNIA Forms Bond OGD114 DEPARTMENT OF CONSERVATION 4GD121 DIVISION OF OIL, GAS, AND GEOTHERMAL RESOURCES M-0 NOTICE OF INTENTION TO DRILL NEW WELL Detailed instructions can be found at: Ih compliance with Section 3203, Division 3, Public Resources Code, notice is hereby given that it is our intention to drill well Red Ribbon Ranch #92 well type Oil API No. (Assigned by �Division] 27 T. 29S R. 27E MD B.&M., Fruitvale Field, Kern County. Legal description of mineral-right lease, consisting of 300 acres (attach map or plat to scale), is as follows: Lots 1, 8, 9, 14, 16, 17, 18, 19, 22, 23, 24, 25, 26,&27 in Sec 27, except the W. 24 acres of lot 27 and E/2 of lot I 0 l o mineral and surface leases coincide? Yes0 Non. If answer is no, attach legal description of both surface and mineral leases, a�d map or plat to scale. Location of well 2460 feet North along section property [:] line and 1900 feet West (Direction) (Check one) (Direction) at right angles to said line from the Southeast corner of section property r_1 27 and (Check one) Lot./Long. in decimal degrees, to six decimal places, NAD 83 format: Latitude: 35.3754706* Longitude: -119-06293640 if IWO is to be directionally drilled, show proposed coordinates (from surface location) and true vertical depth at total depth: feet - and - feet (Direction) (Direction) . Estimated true vertical depth 4500 Elevation of ground above sea level 397 feet. All depth measurements taken from top of Kelly Bushing that is 14 feet above ground. (Derrick 600r, —Rotary Table, or Kelly Bushing) — Is this a critical well as defined in the California Code of Regulations, Title 14, Section 1720(a) (see next page)? Yes❑ Non Is is California Environmental Quality Act (CEQA) document required by a local agency? Yes❑ No[D If yes, see next page. PROPOSED CASING PROGRAM i SIZE OF CASING WEIGHT GRADE AND TOP BOTTOM ("Inches APQ TYPE 16" '1a" Wall Conductor 01 54' 9-5/8" 36# K-55, BTC 01 500' 5-1/2" 15.5# K-65, LTC 01 4500' CEMENTING I DEPTHS FORMATION CALCULATED FILL BEHIND PRESSURE CASING (Linear Feet) (Estimated Maximum) 54' NA 54' ------------- 500' 500' 3630 ±1300 psi 3630' (Attach a complete drilling program including wellbore schematics in addition to the above casing program) Estimated depth of base of fresh water: 3000' Anticipated geological markers: Martin 3635TVD kName, depth) lntp� nded zone(s) of completion: Martin/Kernco. 3635'TVD, t1300 psi Estimated total depth: 4500' (Name, depth and expected pressure) rho.- Division must be notified immediately of changes to the proposed operations. Failure to provide a true and accurate representation of the well and proposed operations may cause rescission of the permit. Sari Joaquin Facilities Management 4520 California Ave, Suite 300 1 Name of Person Filing Notice Telephone Number: Tim,. . Spriet 1(661) 337-9770 lndivkdual to contact for technical questions: Telephone Number: Tim Spriet (661) 337-9770 '! City/State Zip— —Code Bakersfield, CA 93309 Signature Date 5&?w&� aq Sp.,-L,, 7/28/14 tim.sprietO,driltek.com Thlis notice and an indemnity or cash bond shall be filed, and approval given, before drilling begins. If operations have not commenced within one year of the Division's receipt of the notice, this notice will be considered cancelled. OG1165 (08/M)