Loading...
HomeMy WebLinkAboutFIRE PREVENTION INSPECTIONf ; BAKERSFIELD FIRE. DEPARTMENT TT DDQQ ``,, TT N INSPECTION . Prevention Services r B � R S' F >> L D , FIRE- .2.101 H Street aRrM r Bakersfield,-CA 93301 Phone: 661 - 326 - 39:79 • Fax:; 661 - 852 -2171. ' DISTRICT BLOCK NO.. DATE' .- - FEE FACILITY ADDRESS CITY, STATE, ZIP - FACILITY.NAME r. 'MANAGER'S NAME PH, NO. BUSINESS :OWNER'S NAME AND ADDRESS CITY, STATE, ZIP PH NO. - BILL TO: (IF DIFFERENT FROM. ABOVE) NAME, ADDRESS .. CITY, STATE, ZIP, PH NO. OCC TYPE OCC LOAD NO OF FLOORS. HIGH RISE BLDG'. RISER,DATE ., : ❑ YES , :I�NO CORRECT ALL VIOLATIONS VIOLATION REQUIREMENTS CHECKED BELOW N0. 1 Remove a,nd safely dispose of all hazardous .refuse and dry.vegetation on the above premises. (CFC COMBUSTIBLE WASTE' I DRY 3 0 4:1.1 ) VEGETATION 2 Provide non: - _.combustible containers with tight fitting'li.ds for the.stora.ge of combustible waste.and rubbish. pending its safe disposal. (CFC ::30'4,3.2)- .Note: applies`to containers over 40 gala.ons. coMBUSTIBLE STORAGE 3. `i. Relocate combustible storage to provide at. least 3 feet clearance around.motor'f.use box. /f,ire door (CFC -- ' 605:3) 4 R- elocat:e ,fire extingu,isher.(s) so that they: will be in a conspicuous location; hanging on brackets with the top to the extinguisher no.t more than 5.:feet.6bove -•the floor,. (CFC 906..5 & 906,9) EXTINGUISHERS __ Provide an d install: (amount) __ -_. approved (type &size) _ —__ portable fire exti..nguisher to be immediately accessible fo.r use in' (area`) _______ ___ _____ (CFC - - - - -- TABLE 906.3(1)) '6 Re= charge all fire. extinguishers. Fire`ext.inguishers shall `be 'serviced. at least once each year, . an.d /or after each use; by a person 'having a:,v_alid: License oreertifica;te.` (CF0,90.6.2) . Provide'an.d. maintain "'EXIT" sign.(s)- with Fetters 6 or more inches in height over each required exit., SIGNS' i (door /window) to. fire. escape., (CFC. 1011) g Provide and maintain. appropriate. numbers on a contrasting, background and_visble. from_�the street to .. indicate the correct address of the building. ('CFC 505A) 9 Repair all '(cracks /holes /openings) in plaster in (location) ----------------------------- _ FIRE DOORS Plastering shall return the surface to i.ts.origi.nal fire.resistive`cond.i:tion.' (CFC703;;1) FIRE SEPARATIONS 10 Remove/repair. (item & :location ') - - - - - -- - -- - -- -- -------------------------- -- -- - - - - -- Self= closing doors shall be designed to close by gravity', or by the action of a: m:echanic.al, device, or by an app :roved smoke and'heat.sees:itive device. Self= .closing: doors shall :have no attachments capable of preventing the operation of the closing device. (CFC .703:2) Remove all obstruction from h.allwa.ys. Maintain all,means of'egress.free.of any storage. (CFC.1028.3) EXITS 1z Provide a .contrasting colored. and permanently, insta:l,led electric, light.ove'r or near required exit to c.le (l o catlo n) --------------- = - - - -- — - - -- a r ly i n d i ca to : i t a s a.n exit .. (C F`C :10 0 6.3 Remove a.li storage and /or, other obstructions from 'fire'esca'pe ;land.in_gs a.nd. stairw :ays stair shafts.. (Fire : STORAGE 13 escapes /stair shafts are to be maintained free from obstructions "at all times.) (CFC.1003.6). 14 Extension. cords shall not be. used in lieu of permanent ap.,p :roved wiring. Install additional.approved ELECTRICAL APPLIANCES electrical outlets where needed. (CFC 605.5) .• 15' Remove multiple attachment cords from. pecifi:c electrical convenience outlet (one plug..per outlet). (C.FC OUTDOOR BURNING . 16 Recreationa'I fires or open. burning. CFC 307..1 FIREWORKS, 17. Violations of Section (CFC 5608:1). & 8.4.4.040 (B.M.C.). .OTHER 18' CORRECTION'. DATE •, ': rt 'Corr'ectthe. violations noted' above b r y' LEGEND - �` C.P.C. CALIFORNIA FIRE CODE CALIFORNIA BUILDING CODE CUSTOMER:` B M.C. SAKERSFIELD .MU. (Signature) (Please Print Name Legibly, Title) N.F.P.A . NATIONAL FIRE P ROTECTIONDE IN5PECTOR: _ NO . _ f ASSOCIATION N.E.C. NATIONAL ELECTRIC CODE