Loading...
HomeMy WebLinkAbout2013 FMC RESULTS'TAIT !--:7 141560!8222 �iv, yi, i -.o ryi December 19, 2013 VIA FED EX 7721 5773 8378 Bakersfield Fire Department 2101 H Street Bakersfield CA 93301 Re: Product Line Testing Monitoring System Certification Spill Bucket Testing Pacific Bell Telephone Co. dba AT&T California 1918 I'M" STREET, BAKERSFIELD, CA GEOPAR: SA004 To Whom It May Concern: Enclosed are the results for the following tests completed on December 2, 2014: ■ Product Line Testing Report Form ■ Monitoring System Certification Report Form ■ Spill Bucket Testing Report Form Please do not hesitate to call me if you have any questions. Very Truly Yours, �aalrlos E. Cardenas Program Manager CA ::ic MO98 AZ 095984 11: NV hc;; 0049666 1 TX CU000041 DATA CHART FOR USE WITH PETRO TITS LINE TESTER Job Number: ATTPL14 Date of Test: 12/02/2014 LOCATION: 1918 M STREET BAKERSFIELD CA. OWNER: OPERATOR: REASON FOR TEST: TEST REQUESTED BY: Street No. city State Telephone No. Pacific Bell Telephone Company dba AT&T California Name Address Representative Position Telephone No. Grant Armstrong Environmental Site Manager 661-327-6903 Name Dealer, Mgr. Or Other Address (if different than location) Telephone No. Annual Compliance Shane Gardner Bakersfield Fire Dept. Name Position SPECIAL IMIKULAIUNZ: TECHNICIAN: Patrick Banbury ,-4 Name IS A TANK TEST TO BE MADE WITH THIS LINE TEST? MAKE AND TYPE OF PUMP OR DISPENSERS WEATHER Overcast COVER OVER LINES Concrete I Black Top Order No. Signature ❑ Yes [D No FE- PETRO TURBINE Billing Address 90-1413 License Number TEMPERATURE IN TANKS OF Oc APPROX. BURIAL DEPTH 24" Concrete, Black Top, Etc. PRESSURE VOLUME EACH LINE TIME PSI READING TEST RESULTS AS TESTED MILITARY) BEFORE AFTER BEFORE AFTER NET CHANGE CONCLUSIONS DIESEL 1045 START 80 +.0000 G.P.H. Line Tight E YES ❑ NO Bleed Back 0 OK ❑ NOT OK SA0040001 1115 STABILIZATION 80 60 1145 START TEST 60 60 1200 60 60 .0570 .0570 +.0000 1215 60 60 .0570 .0570 +.0000 1216 BLEED BACK 60 0 .0570 .0910 +.0340 BLEED BACK START TEST BLEED BACK BLEED BACK START TEST BLEED BACK COMMENTS: Local CUPA on site Shane Gardner. 1.5" Western Fiberglass Flex Line. G.P.H. Line Tight F-1 YES ❑ NO Bleed Back r-1 OK F-1 NOT OK G.P.H. Line Tight F-1 YES F-1 NO Bleed Back F-1 OK ❑ NOT OK Appendix VI (Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at http: / /w•ww.waterboards.ca.gov .) MONITORING SYSTEM CERTIFICATION For Use By,411 Jurisdictions Within the State of California Authority Cited. Chapter 6.7, Health andSafety Code; Chapter 16, Division 3, Title 23, California Code ofRegulations This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner /operator owner /operator must submit a copy ofthis form to the local agency regulating UST systems within 30 days of test date. A. General Information Facility Name: Pacific Bell Telephone Co. dba AT &T California Building No.: SA004 Site Address: 1918 M STREET City: Bakersfield Zip: 93301 The Facility Contact Person: Grant Armstrong Contact Phone No.: (661) 327 -6903 Make/Model of Monitoring System: Veeder Root TLS -350 Plus Date of Testing/Servicing: 12/2/2014 B. Inventory of Equipment Tested /Certified Check the appropriate boxes to indicate specific equipment inspected /serviced: Tank ID: SA004U001�� _�_,.w,_,_._,.,•...,.,. -..� ,...�� .w.,.w..�...�.....M,...�... Tank ID. In -Tank Gauging Probe. Model: 846390 - 109/729482 In -Tank Gauging Probe. Model: 794390-420/N/A kk Annular Space or Vault Sensor. Model: F Annular Space or Vault Sensor. Model: ')v 794380- 208/729482 Piping Sum / Trench Sensors . Model: Piping Sump/ Sensor(s). Model: p g p () Fill Sump Sensor(s). Model: 794380- 208/797241 Fill Sump Sensor(s). Model: } F Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: j F Electronic Line Leak Detector. Model: F Electronic Line Leak Detector. Model: '. Tank Overfill / High -Level Sensor. Model: 790091 -001 r Tank Overfill / High -Level Sensor. Model: € Other (specify equipment type and model in Section on Page 2). F Other (specify equipment type and model in Section on Page 2). :°aXSU.azo:.•n;,x �xx::rx„- .a.:x- ;.,-: s::: �tts�x: �a» ax��uaraaax :✓••�"x:•a. >: >kz: ^,:::nm�: x:a;.•:x;;.�;xmra �z. ra�v;. vzacuwc�ww» ax> e, 7:.: ::r.„,;,:ws:r;.a- x;^,:wxcrrxs� wcx;c �' '�,s�e. ° Y. h.";'" 5¢% �;. a" a', ?X�"���`Fc�&zika�`"F✓4t,,xgmr,„ �' .. ... .... .. Tank ID: Tank ID. In -Tank Gauging Probe. Model: In -Tank Gauging Probe. Model: Annular Space or Vault Sensor. Model: Annular Space or Vault Sensor. Model: Piping Sump/ Trench Sensor(s). Model: Piping Sump/ Trench Sensor(s). Model: Fill Sump Sensor(s). Model: r Fill Sump Sensor(s). Model: Mechanical Line Leak Detector. Model: F Mechanical Line Leak Detector. Model: F Electronic Line Leak Detector. Model: F Electronic Line Leak Detector. Model: F Tank Overfill / High -Level Sensor. Model: Tank Overfill / High -Level Sensor. Model: j Other (specify equipment type and model in Section E on Page 2). Other (specify equipment type and model in Section on Page 2). Dispenser ID:� Dispenser ID: Dispenser Containment Sensor(s). Model: r Dispenser Containment Sensor(s). Model: Shear Valve(s). Shear Valve(s). k Dispenser Containment Float(s) and Chain(s). Dispenser Containment Float(s) and Chain(s). � Dispenser ID' Dispenser ID: Dispenser Containment Sensor(s). Model: _� Dispenser Containment Sensor(s). Model: i Valve(s). Shear Valve(s). �� Shear e( s )• { � k j Dispenser Containment Float(s) and Chain(s). F Dispenser Containment Float(s) and Chain(s). *If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. C. Certification - I certify that the equipment identified in this document was inspected /serviced in accordance with the manufacturers' guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a copy of the report; (check all that apply) : System set -up Alarm history report Technician Name (print): Pat Banbury Signature: Certification No.: A20465 License. No.: 588098 Testing Company Name: TAIT ENVIRONMENTAL SERVICES Phone No.: 714560 -8222 Testing Company Address: 2131 soUTHDUPON U;UV y Ar1A1MM,CA92806 Date of Testing/Servicing: 12/2/2014 D. Results of Testing /Servicing Software Version Installed: 123.01 Complete the following checklist: ,�..,�.�...�.,. ..�.. � ..... _.,... �.w MM,_wM � � p..__ __ww,.__._ w_ w.. ------ Yes No* Its the audible alarm operational? �ys��'..,, GF' �K�. i3.. s``.'. r` z.'."` w3,' a'' w`'=.'"' n' a'':". r� "`m.�"a'S��'x�a'x"a�4``�"�i:'�. `..Y�"Y'�.'.�`?a' �xs'.v t. � .?`ks.�uu'"`i'$s�.c�%'���«.�`3' `•6,v� Yes N o *. ,= Is the visual alarm operational? v `-' ; Were all sensors visually inspected, functionally tested, an conrme operational? €�. � Yes s� No * W i f i ll d d fi d ,, f.- M�..��- ��,,_._,,...,.. � �.r��____ m��_:�.�.. �..�N..�_...�.���.�mmw..� _�- �w.��..�:;�w:� w�mm���µ :�.�:�,.�:,�,�•,.....�..� . ���. �,. �. ���� ..�.�.�m,.:m�,:m.�..�r��w��mm.m �.�.�� € fF Yes F No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere with theirs proper operation? ��u` x`. z` k? 8:;,' sswa�s.`.' s.<; e.: 3s' fii°•' QP's A.'.8.`.`�s..E.k�.'P<'%,P,m..�' .`,.�,":?az<s:�..;c."aY.'z;:>& .-; sCw^.'.''"? 3,' a`: a...` r, d?.., k2': t. c: o. aiz"" s' iaa'`."., aa' 7s3" 3: i.`. y2:: a�n ;�us't::;`x�.'za>5'"�Snat''r,. yr4"..0 >srr.: - .:$STr.<. .","Ii.h^.:'E3 �q * Yes No* If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) t N/A ` =operational. s �y ... ... .... .. ..y, :,_b. 'T' ak.'S ]S# ... , .. , .; ..� ,. .,+.wd.: `'Er. .mu <. ¢'Y •tJ.• y;. ,>� ,:Yw -y ..+,., �y,y ...SY ` �.`�$�. '�``^.:' '(a.. ,Z..wt� =ir:�.�r:(��R:. ..`=?.3kkk'::;'.�p1 '�.;..�5'.R3".�..eLk".i ..aw.='c.�.�b'zx,.?c`"x: �.. �%,,.: 3% a... �.. P£ O..>??> ��e"'.. K�%. v.°,< �3. �` �C���:, ffi` ��e,'.. �.' �a° �2" a` a�`'" r35,<> �. r�: a.<.".., 9...,... .:rsk�..n�.�iO'C.°..�ea"�.�.'�. ". ��s��y a�. �.`.»$ �.' �s�e�,> s.` y',". �'° �"°. A. �v. �. ix�..,.. ��ias: 5�' c' �° ios3�i�:" F:.. �: M"` 3' .':�.<"t3':.v�'�.�v.«S,�'�..n. ,,,". �' i.;.+\`%," ro�. �' �.><.+a�.��v°:.T.. >�.w.s:•.,.�m X59..., >,., „X.&.s$ Yes No * For pressurized piping systems, does the turbine automatically shut down if the piping secondary N/A ;containment monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate positive shut -down? (Check all that apply)' ' F Sump /Trench Sensors; r Dispenser Containment Sensors. Did you confirm positive shut-down due to leaks and sensor failure /disconnection? F F Yes; F N o. Yes No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the a; N/A = =tank fill point (s) and operating properly? If so , at what percent of tank capacity ndoes the alarm tri gg er? J; €�. % w Yes v No any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment �i f replaced and list the manufacturer name and model for all replacement parts in Section E, below. EYes *) ' No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) r Product; F Water. If yes, describe causes in Section E, below. Yes No* Was monitoring system set -up reviewed to ensure proper settings? Attach set up reports, if applicable Yes No* $GIs all monitoring equipment operational per manufacturer's specifications ?' * In SectionE below, describe how and when these deficiencies were or will be corrected E. Comments: Other lens ors from page one: L4 Piping transition sump sensor 794380 -208/ N/A certified L5 Day tank containment sensor 794380- 208 - 930304 certified. L6 Generator room floor sensor 7943 80- 208/930141 certified. A mechanical drop tube overfill prevention valve is installed as primary overfill. F. In -Tank Gauging / SIR Equipment: Check this box if tank gauging is used only for inventory control. Check this box if no tank gauging or SIR equipment is installed This section must be completed if in -tank gauging equipment is used to perform leak detection monitoring. *In the Section H, below, describe how andwhen these deficiencies were or will be corrected. G. Line Leak Detectors (LLD): Check this box if LLDs are not installed. Complete the following checklist: Yes . ° No* For equipment start -up or annual equipment certification, was a leak simulated to verify LLD performance ?(Check N/A : all that apply) Simulated 1 eak rate: F 3 g. p.h.; 0.1 g. p. h ; 0.2 g.p.h. ....�..............�.. ...... ...... Yes f No* Were all LLDs confirmed operational and accurate within regulatory requirements? Yes a F No* Was the testing apparatus properly calibrated? fYes F No* For mechanical LLDs, does the LLD restrict product flow if it detects a leak? r � I l N/A i Yes No* For electronic LLDs, does the turbine automatically shut off ifthe LLD detects a leak? k N/A i Yes No* For electronic LLDs, does the turbine automatically shut off ifany portion of the monitoring system is disabled or disconnected? s #I F Yes F No* For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or N/A fails a test? y ..... ..:...».».�a..n..... w.�w '...........:....w.v..w..rr . r.....+..........+ .............ua.uw . r....a..n.....vv......w..... .....,......,. ...,.. u....... w.... x.. www+.......................... .... ... w.... x... n. ... wrw».. r .rM...w.r.rmmmnrw..mw.......... .V..v....w.vnwmmmv.......... tS Yes i No* For electronic LLDs, have all accessible wiring connections been visually inspected? >a ! N/A � Yes � �' No* Were all items on the equipment manufacturer's maintenance checklist completed? * In the Section H, below, describe how and when these deficiencies were or will be corrected. H. Comments: Pressurized double wall supply line. The supply line passed a precision line rest. Site Address • 1918 M STREET, Bakersfield, 93301 atat UST Monitoring Site Plan Monitoring Plan Site Flap Business Name: Pacific Bell Telephone Co. dba AT &T Cal. (SA004) Business Address: 1980 M St Bakersfield Fluor Sensor 11-5) 794380 -208 N S Drawing NOT to Scale Transition Sump wl Sensor (L4) 794380 -208 Vent Riser --� ;` IL71 1NMAt -4ZU Fill ' Sump vrl Sensor Vent Line I j - 1-2. 79438t 2i8, Spill Bucket & ATG Fuel Lines - I I SAD04€1009 I i 20K UST Diesel Piping Sump W1 Sensor (1-3) 794380 -208 Date map was drawn: 12/2/2014 Instructions If you already have a diagram that shows all required information, you may include it, rather than this page, with your Monitoring System Certification. On your site plan, show the general layout of tanks and piping. Clearly identify locations of the following equipment, if installed: monitoring system control panels; sensors monitoring tank annular spaces, sumps, dispenser pans, spill containers, or other secondary containment areas; mechanical or electronic line leak detectors; and in -tank liquid level probes (if used for leak detection). In the space provided, note the date this Site Plan was prepared Spill Bucket Testing Report Form This form is intendedfor use by contractors performing annual testing of UST spill containment structures. The completed form and printouts from tests (if applicable), should be provided to the facility owner /operatorfor submittal to the local regulatory agency. FAC'TT.TTV INFORMATION Facility M- SA004 Facility Name: Pacific Bell Telephone Co. dba AT &T California Date of Testing: 12 /2/2014 Facility Address: 1918 M STREET, Bakersfield, CA 93301 Facility Contact: Grant Armstrong Phone: 661- 327 -6903 Date Local Agency Was Notified of Testing. 2014 -10 -23 Name of Local Agency Inspector (ifpresent during testing): Shane Gardner T1P4ZTTNC;' CnNTRAC'TnP TNFnPMATION Company Name: TAIT Environmental Services, Inc. Technician Conducting Test: Pat Banbury Credential I : CSLB Contractor ICC Service Tech. r SWRCB Tank Tester Other (Specify) License number(s): A B ASB C -10 HAZ License Number 588098 : 5254955 GATT T RTTi -k'l 'r TTi'QTTNC:' TNFnPI%4ATInN Test Method Used: Hydrostatic Vacuum Other Test Equipment Used: Tape Measure Equipment Resolution: 1/ 16th inch Identify Spill Bucket (By Tank Number, Stored Product, etc. 1 SA004UO01 Bucket Installation Type: Direct Bury Contained in Sump On top of AST Direct Bury Contained in Sump On top of AST Direct Bury F Contained in Sump r7 On top of AST Direct Bury Contained in Sump r7 On top of AST Bucket Diameter: 11" Bucket Depth: 16.5" Wait time between applying vacuum /water and start of test: 5 min Test Start Time (TI): 9:55 am Initial Reading (RI): 15.5" Test End Time (TO: 10:55 am Final Reading (RF): 15.5" Test Duration (TF — TI): One H our Change in Reading (RF -RI): 0.00" Pass/Fail Threshold or Criteria: 0.00" Test Result: Pass Fail r Pass 17 Fail Pass Fail Pass Fail Comments — (include information on repairs made prior to testing, and recommendedfollow -zip for Jailed tests) Transport test water to Tait shop. CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING I hereby certify that all the information contained in this report is true, accurate, and in full compliance with legal requirements. Technician's Signature: Date: 12/2/2014 I 5 0,3 01 DEC 9, 2014 9:04 AM # 1:BKFDCAI2 SA004 S -S L I50302 DEC 9, 2014 9:04 AM # 2:1918 M ST. L I50303 DEC 9, 2014 9:04 AM # 3:BAKERSFIELD,CA 93301 L I50304 DEC 9, 2014 9:04 AM # 4:661- 631 -2540 L I51700 DEC 9, 2014 9:04 AM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE /TIME FORMAT MON DD YYYY HH:MM:SS xM L I50F00 DEC 9, 2014 9:04 AM MON DD YYYY HH:MM:SS xM L I10200 DEC 9, 2014 9:05 AM BKFDCA12 SA004 S -S. 1918 M ST. BAKERSFIELD,CA 93301 661- 631 -2540 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 4 PROBE / G.T. 163858 162909 2 INTERSTITIAL BD 201571 200974 3 UNUSED 9807749 9740626 4 UNUSED 9779270 9731856 5 UNUSED 9773701 9733099 6 UNUSED 9777894 9736328 7 UNUSED 9762690 9729456 8 UNUSED 9771838 9745252 9 COMBO I/O BOARD 9933 9969 10 COMBO I/O BOARD 9955 9969 11 UNUSED 9777370 9740536 12 UNUSED 9766698 9732681 13 UNUSED 9769260 9735321 14 UNUSED 9767566 9728231 15 UNUSED 9766910 9741321 16 UNUSED 9765364 9730129 COMM 1 FAXMODEM BOARD 40262 40298 COMM 2 UNUSED 9774427 9739772 COMM 3 UNUSED 9760324 9728973 COMM 4 UNUSED 9766571 9740448 COMM 5 UNUSED 9764941 9726900 COMM 6 UNUSED 9764496 9736783 L I60100 DEC 9, 2014 9:05 AM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 DIESEL TK #SA004U001 ON 2 OFF 3 OFF 4 OFF L I60200 DEC 9, 2014 9:05 AM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 DIESEL TK #SA004U001 2 3 4 L I60300 DEC 9, 2014 9:05 AM TANK PRODUCT CODE TANK PRODUCT LABEL 1 DIESEL TK #SA004U001 1 2 2 3 3 4 4 L 260400 DEC 9, 2014 9:05 AM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 DIESEL TK #SA004U001 20149 2 0 3 0 4 0 L I60700 DEC 9, 2014 9:06 AM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 DIESEL TK #SA004U001 114.00 2 0.00 3 0.00 4 0.00 L I60900 DEC 91 2014 9:06 AM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 DIESEL TK#SA004U001 0.000450 2 0.000000 3 0.000000 4 0.000000 L I61200 DEC 9, 2014 9:06 AM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS 1 DIESEL TK #SA004U001 NONE 2 NONE 3 NONE 4 NONE L 162100 DEC 9, 2014 9:06 AM LINE MANIFOLDED TANKS NONE NONE NONE NONE TANK LOW 'PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL TK #SA004U001 12000 2 0 3 0 4 0 L 262200 DEC 9, 2014 9:06 AM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL TK #SA004U001 19141 2 0 3 0 4 0 L I62300 DEC 9, 2014 9:06 AM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL TK #SA004U001 18134 2 0 3 0 4 0 L 262400 DEC 9, 2014 9:06 AM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 DIESEL TK #SA004U001 2.0 L I62800 DEC 9, 2014 9:06 AM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL TK #SA004U001 20149 2 0 3 0 4 0 L I62900 DEC 9, 2014 9:06 AM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL TK #SA004U001 12000 2 0 3 0 4 0 L 270300 DEC 9, 2014 9:06 AM LIQUID TYPE SENSOR LOCATION TYPE 1 ANNULAR SPACE TRI -STATE (SINGLE FLOAT) 2 FILL SUMP TRI -STATE (SINGLE FLOAT) 3 PIPING SUMP TRI -STATE (SINGLE FLOAT) 4 TRANSITION SUMP TRI -STATE (SINGLE FLOAT) S DAY TANK CONTAINMENT TRI -STATE (SINGLE FLOAT) 6 GEN ROOM FLOOR TRI -STATE (SINGLE FLOAT) 7 TRI -STATE (SINGLE FLOAT) 8 TRI -STATE (SINGLE FLOAT) L 290200 DEC 9, 2014 9:07 AM SOFTWARE REVISION LEVEL •VERSION 123.01 SOFTWARE## 346123 -100 -B CREATED - 02.06.21.13.00 S- MODULE# 330160 -002 -A SYSTEM FEATURES: PERIODIC IN -TANK TESTS ANNUAL IN -TANK TESTS CSLD I11100 DEC 9, 2014 9:08 AM BKFDCAI2 SA004 S -S 1918 M ST. BAKERSFIELD,CA 93301 661 -631 -2540 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME I 3 INPUT GEN RUN EXTERN INPUT ALARM CLEAR 12 -05 -14 7:54PM I 3 INPUT GEN RUN EXTERN INPUT ALARM ALARM 12 -05 -14 7:54PM I 3 INPUT GEN RUN EXTERN INPUT ALARM CLEAR 12 -05 -14 7:52PM I 3 INPUT GEN RUN EXTERN INPUT ALARM ALARM 12 -05 -14 7 :52PM I 3 INPUT GEN RUN EXTERN INPUT ALARM CLEAR 12 -05 -14 7:51PM I 3 INPUT GEN RUN EXTERN INPUT ALARM ALARM 12 -05 -14 7:50PM I 3 INPUT GEN RUN EXTERN INPUT ALARM CLEAR 12 -05 -14 7:50PM I 3 INPUT GEN RUN EXTERN INPUT ALARM ALARM 12 -05 -14 7:49PM I 3 INPUT GEN RUN EXTERN INPUT ALARM CLEAR 12 -05 -14 7 :49PM I 3 INPUT GEN RUN EXTERN INPUT ALARM ALARM 12 -05 -14 7:43PM I 3 INPUT GEN RUN EXTERN INPUT ALARM CLEAR 12 -05 -14 7:43PM 13 INPUT GEN RUN EXTERN INPUT ALARM ALARM 12 -05 -14 7:43PM I 3 INPUT GEN RUN EXTERN INPUT ALARM CLEAR 12 -05 -14 7:40PM I 3 INPUT GEN RUN EXTERN INPUT ALARM ALARM 12 -05 -14 7:40PM I 3 INPUT GEN RUN EXTERN INPUT ALARM CLEAR 12 -05 -14 7:40PM I 3 INPUT GEN RUN EXTERN INPUT ALARM ALARM 12 -05 -14 7:40PM I 3 INPUT GEN RUN EXTERN INPUT ALARM CLEAR 12 -05 -14 7:36PM 13 INPUT GEN RUN EXTERN INPUT ALARM ALARM 12 -05 -14 7:32PM I 3 INPUT GEN RUN EXTERN INPUT ALARM CLEAR 12 -05 -14 7:27PM I 3 INPUT GEN RUN EXTERN INPUT ALARM ALARM 12 -05 -14 7:20PM I 3 INPUT GEN RUN EXTERN INPUT ALARM CLEAR 12 -05 -14 7:19PM I 3 INPUT GEN RUN EXTERN INPUT ALARM ALARM 12 -05 -14 7:19PM I 3 INPUT GEN RUN EXTERN INPUT ALARM CLEAR 12 -05 -14 7:18PM I 2 INPUT PUMP RUN EXTERN INPUT ALARM CLEAR 12 -05 -14 7:17PM I 3 INPUT GEN RUN EXTERN INPUT ALARM ALARM 12 -05 -14 7:09PM I 3 INPUT GEN RUN EXTERN INPUT ALARM CLEAR 12 -05 -14 7:09PM I 3 INPUT GEN RUN EXTERN INPUT ALARM ALARM 12 -05 -14 7:08PM I 3 INPUT GEN RUN EXTERN INPUT ALARM CLEAR 12 -05 -14 7:08PM I 3 INPUT GEN RUN EXTERN INPUT ALARM ALARM 12 -05 -14 7:08PM I 2 INPUT PUMP RUN EXTERN INPUT ALARM ALARM 12 -05 -14 7:07PM I 3 INPUT GEN RUN EXTERN INPUT ALARM CLEAR 12 -05 -14 7:05PM I 3 INPUT GEN RUN EXTERN INPUT ALARM ALARM 12 -05 -14 7:05PM I 3 INPUT GEN RUN EXTERN INPUT ALARM CLEAR 12 -05 -14 7:04PM I 3 INPUT GEN RUN EXTERN INPUT ALARM ALARM 12 -05 -14 7:04PM I 3 INPUT GEN RUN EXTERN INPUT ALARM CLEAR 12 -05 -14 6:49PM I 3 INPUT GEN RUN EXTERN INPUT ALARM ALARM 12 -05 -14 6:45PM I 3 INPUT GEN RUN EXTERN INPUT ALARM CLEAR 12 -05 -14 6:39PM I 3 INPUT GEN RUN EXTERN INPUT ALARM ALARM 12 -05 -14 6:26PM I 3 INPUT GEN RUN EXTERN INPUT ALARM CLEAR 12 -05 -14 5:53PM I 3 INPUT GEN RUN EXTERN INPUT ALARM ALARM 12 -05 -14 5:52PM I 3 INPUT GEN RUN EXTERN INPUT ALARM CLEAR 12 -05 -14 5:42PM 13 INPUT GEN RUN EXTERN INPUT ALARM ALARM 12 -05 -14 5:42PM 13 INPUT GEN RUN EXTERN INPUT ALARM CLEAR 12 -05 -14 5:41PM 13 INPUT GEN RUN EXTERN INPUT ALARM ALARM 12 -05 -14 5:40PM I 3 INPUT GEN RUN EXTERN INPUT ALARM CLEAR 12 -03 -14 4:46AM I 3 INPUT GEN RUN EXTERN INPUT ALARM ALARM 12 -03 -14 4:32AM I 3 INPUT GEN RUN EXTERN INPUT ALARM CLEAR 12 -03 -14 4:27AM I 3 INPUT GEN RUN EXTERN INPUT ALARM ALARM 12 -03 -14 3:11AM 13 INPUT GEN RUN EXTERN INPUT ALARM CLEAR 12 -03 -14 2:55AM I 3 INPUT GEN RUN EXTERN INPUT ALARM ALARM 12 -03 -14 2:50AM I11200 DEC 9, 2014 9:09 AM BKFDCAI2 SA004 S -S 1918 M ST. BAKERSFIELD,CA 93301 661 -631 -2540 NON - PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 1 TANK DIESEL TK##SA004U001 LOW TEMP WARNING CLEAR 12 -02 -14 10:51AM T 1 TANK DIESEL TK #SA004U001 LOW TEMP WARNING ALARM 12 -02 -14 10:48AM T 1 TANK DIESEL TK #SA004U001 HIGH WATER WARNING CLEAR 12 -02 -14 10:48AM T 1 TANK DIESEL TK #SA004U001 HIGH WATER WARNING ALARM 12 -02 -14 10:37AM T 1 TANK DIESEL TK #SA004U001 HIGH PRODUCT ALARM CLEAR 12 -02 -14 10:31AM T 1 TANK DIESEL TK #SA004U001 HIGH PRODUCT ALARM ALARM 12 -02 -14 10:29AM T 1 TANK DIESEL TK #SA004U001 DELIVERY NEEDED CLEAR 12 -12 -13 10:20AM T 1 TANK DIESEL TK #SA004U001 DELIVERY NEEDED ALARM 12 -12 -13 10:19AM T 1 TANK DIESEL TK #SA004U001 HIGH WATER WARNING CLEAR 12 -12 -13 9:58AM T 1 TANK DIESEL TK #SA004U001 HIGH WATER WARNING ALARM 12 -12 -13 9:54AM T 1 TANK DIESEL TK #SA004U001 HIGH PRODUCT ALARM CLEAR 12 -12 -13 9:47AM T 1 TANK DIESEL TK #SA004U001 HIGH PRODUCT ALARM ALARM 12 -12 -13 9:47AM T 1 TANK DIESEL TK #SA004U001 INVALID FUEL LEVEL CLEAR 12 -12 -13 9:45AM T 1 TANK DIESEL TK #SA004U001 INVALID FUEL LEVEL ALARM 12 -12 -13 9:45AM T 1 TANK DIESEL TK #SA004U001 HIGH WATER WARNING CLEAR 4 -11 -13 12:14PM T 1 TANK DIESEL TK #SA004U001 LOW TEMP WARNING CLEAR 4 -11 -13 12:14PM T 1 TANK DIESEL TK #SA004U001 LOW TEMP WARNING ALARM 4 -11 -13 12:13PM T 1 TANK DIESEL TK #SA004U001 HIGH PRODUCT ALARM CLEAR 4 -11 -13 12:06PM T 1 TANK DIESEL TK #SA004U001 HIGH PRODUCT ALARM ALARM 4 -11 -13 12:06PM T 1 TANK DIESEL TK #SA004U001 LOW TEMP WARNING CLEAR 2 -01 -13 3:58PM T 1 TANK DIESEL TK #SA004U001 LOW TEMP WARNING ALARM 2 -01 -13 3:54PM T 1 TANK DIESEL TK #SA004U001 LOW TEMP WARNING CLEAR 2 -01 -13 3:49PM T 1 TANK DIESEL TK##SA004U001 LOW TEMP WARNING ALARM 2 -01 -13 3:41PM T 1 TANK DIESEL TK #SA004U001 LOW TEMP WARNING CLEAR 2 -01 -13 7:33AM T 1 TANK DIESEL TK #SA004U001 LOW TEMP WARNING ALARM 2 -01 -13 7:24AM T 1 TANK DIESEL TK #SA004U001 LOW TEMP WARNING CLEAR 2 -01 -13 7 :17AM T 1 TANK DIESEL TK#SA004U001 LOW TEMP WARNING ALARM 2 -01 -13 6:55AM T 1 TANK DIESEL TK #SA004U001 LOW TEMP WARNING CLEAR 2 -01 -13 6:44AM T 1 TANK DIESEL TK #SA004U001 LOW TEMP WARNING ALARM 2 -01 -13 6:02AM T 1 TANK DIESEL TK #SA004U001 LOW TEMP WARNING CLEAR 2 -01 -13 5:57AM T 1 TANK DIESEL TK #SA004U001 LOW TEMP WARNING ALARM 2 -01 -13 5:12AM T 1 TANK DIESEL TK #SA004U001 LOW TEMP WARNING CLEAR 2 -01 -13 4:29AM T 1 TANK DIESEL TK #SA004U001 LOW TEMP WARNING ALARM 2 -01 -13 4:06AM T 1 TANK DIESEL TK #SA004U001 LOW TEMP WARNING CLEAR 2 -01 -13 1:41AM T 1 TANK DIESEL TK #SA004U001 LOW TEMP WARNING ALARM 2 -01 -13 1:38AM T 1 TANK DIESEL TK #SA004U001 LOW TEMP WARNING CLEAR 2 -01 -13 12:55AM T 1 TANK DIESEL TK #SA004U001 LOW TEMP WARNING ALARM 2 -01 -13 12 :44AM T 1 TANK DIESEL TK #SA004U001 LOW TEMP WARNING CLEAR 2 -01 -13 12:38AM T 1 TANK DIESEL TK #SA004U001 LOW TEMP WARNING ALARM 2 -01 -13 12:27AM T 1 TANK DIESEL TK #SA004U001 LOW TEMP WARNING CLEAR 2 -01 -13 12:21AM T 1 TANK DIESEL TK #SA004U001 LOW TEMP WARNING ALARM 2 -01 -13 12:14AM T 1 TANK DIESEL TK #SA004U001 LOW TEMP WARNING CLEAR 2 -01 -13 12:05AM T 1 TANK DIESEL TK #SA004U001 LOW TEMP WARNING ALARM 1 -31 -13 11:22PM T 1 TANK DIESEL TK #SA004U001 LOW TEMP WARNING CLEAR 1 -31 -13 11:OOPM T 1 TANK DIESEL TK #SA004U001 LOW TEMP WARNING ALARM 1 -31 -13 10:41PM T 1 TANK DIESEL TK #SA004U001 LOW TEMP WARNING CLEAR 1 -31 -13 10:35PM T 1 TANK DIESEL TK #SA004U001 LOW TEMP WARNING ALARM 1 -31 -13 10:12PM T 1 TANK DIESEL TK #SA004U001 HIGH WATER WARNING ALARM 1 -31 -13 10:08PM T 1 TANK DIESEL TK#SA004U001 LOW TEMP WARNING CLEAR 1 -31 -13 10:08PM T 1 TANK DIESEL TK #SA004U001 LOW TEMP WARNING ALARM 1 -31 -13 9:41PM I20600 DEC 9, 2014 9:11 AM BKFDCA12 SA004 S -S 1918 M ST. BAKERSFIELD,CA 93301 661 -631 -2540 TANK ALARM HISTORY TANK 1 DIESEL TK #SA004U001 HIGH WATER ALARM DEC 2, 2014 10:37 AM DEC 12, 2013 9:54 AM JAN 31, 2013 10:08 PM OVERFILL ALARM DEC 2, 2014 10:30 AM DEC 12, 2013 9:46 AM APR 11, 2013 12:06 PM LOW PRODUCT ALARM DEC 12, 2013 10:19 AM JAN 30, 2013 3:27 PM JAN 30, 2013 2:43 PM HIGH PRODUCT ALARM DEC 2, 2014 10:29 AM DEC 12, 2013 9:47 AM APR 11, 2013 12:06 PM INVALID FUEL LEVEL DEC 12, 2013 9:45 AM AUG 29, 2012 3:13 AM AUG 29, 2012 3:13 AM PROBE OUT DEC 2, 2014 10:46 AM DEC 2, 2014 10:26 AM DEC 12, 2013 9:57 AM HIGH WATER WARNING DEC 2, 2014 10:37 AM DEC 12, 2013 9:54 AM 2014 JAN 31, 2013 10:08 PM DELIVERY NEEDED DEC 12, 2013 10:19 AM 9:08 AM JAN 30, 2013 3:27 PM DEC JAN 30, 2013 2:43 PM MAX PRODUCT ALARM JAN 30, 2013 3:27 PM MAY 31, 2012 11:06 AM LOW TEMP WARNING DEC 2, 2014 10:48 AM FUEL APR 11, 2013 12:13 PM 12, FEB 1, 2013 3:54 PM 130200 DEC 9, 2014 9:12 AM BKFDCA12 SA004 S-S 1918 M ST. BAKERSFIELD,CA 93301 661-631-2540 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 ANNULAR SPACE DEC 2, 2014 9:58 AM FUEL ALARM DEC 12, 2013 9:08 AM FUEL ALARM DEC 20, 2012 9:49 AM FUEL ALARM 2 FILL SUMP DEC 2, 2014 10:04 AM FUEL ALARM DEC 12, 2013 9:14 AM FUEL ALARM DEC 20, 2012 9:57 AM FUEL ALARM 3 PIPING SUMP DEC 2, 2014 10:07 AM FUEL ALARM DEC 12, 2013 9:20 AM FUEL ALARM DEC 20, 2012 10:00 AM FUEL ALARM 4 TRANSITION SUMP DEC 2, 2014 10:11 AM FUEL ALARM DEC 12, 2013 9:28 AM FUEL ALARM DEC 20, 2012 10:04 AM FUEL ALARM 5 DAY TANK CONTAINMENT DEC 2, 2014 10:14 AM FUEL ALARM DEC 12, 2013 9:34 AM FUEL ALARM DEC 20, 2012 10:14 AM FUEL ALARM 6 GEN ROOM FLOOR DEC 2, 2014 10:17 AM FUEL ALARM DEC 12, 2013 9:31 AM FUEL ALARM DEC 20, 2012 10:10 AM FUEL ALARM