Loading...
HomeMy WebLinkAboutHAZ WASTE GENERATOR INSPECTION REPORT 8-11-11HAZARDOUS WASTE BAKERSFIELD FIRE DEPARTMENT UNIFIED PROGRAM CONSOLIDATED FORMS Prevention Services 1501 Truxtun Ave 1sT FLR HAZARDOUS WASTE GENERATOR o r Bakersfield, CA 93301 INSPECTION REPORT I Phone: 661 - 326 -3979 • Fax: 661 - 852 -2171 Facility Name Site Address Date Time In 3r ��� Time Out Owner /Operator Phone Misc. Type of Inspection Inspection Consolidation EPA ID # CAI 050 G & ❑ Routine ❑ Re- inspection/Follow -up Combined Routine Inspection ❑ Joint Inspection ❑ Complaint ❑ Focused ❑ Other ❑ Integrated or Multi -Media Inspection - CUPA Facility 1D# i CONSENT TO INSPECT GRANTED BY (Name / Title): rr) V" /"t V- —,I r'A V:�t° 1— Inspection may involve obtaining photographs, review and copying of records, and determination of compliance with hazardous waste handling requirements. [-Class I Violation, 11 -Class 11 Violation, M -Minor Violation Page of 1 J_ M HAZARDOUS WASTE REQUIREMENTS Code I Y N N/A COMMENTS /NOTES/DOCUMENT(S) REVIEWED MISSING INFORMATION/ UNRESOLVED ISSUES Recordkee in documentation GR01 Generator has an EPA ID number GR02 Hazardous waste determination made for all wastes ❑ Anal sisV Generator Knowled a .! GR03 Contin enc plan information posted near phone GR04 Facility personnel demonstrate training/awareness GR05 Mani fests/Consolidated Manifest receipts complete GR06 Blue co (s) of manifest mailed to Disc GR07 TSDF signed copy of manifest available Win 35 da s of waste shipment GR08 Bills of Ladin recei is available �{ GR09 LDRs available and complete GR 10 1 Onsite recycling reported using UPCF ti Container /tank management GC01 Containers are in good condition GCO2 Containers are closed except when adding/removing GC03 Empty containers are empty GC04 Containers inspected week) GC05 Tanks inspected daily GC06 Satellite containers at or near point of generation GC07 Satellite containers under control of operator GC08 One container per wastestream at satellite area i( GC09 Exclude recyclable materials stored in accordance with local ordinance/hazardous materials codes n Accumulation Time Limits GA01 Waste is accumulated not more than 90/180/270 a zfLT lam% p GA02 Satellite wastes accumulated for less than 1 year GA03 Empty containers managed within one year GA04 Universal waste accumulated less than one year X GA05 Used oil filters offsite within 180 (l year if <1 ton) GA06 Pb -acid batteries offsite within 180 (1 yr. if < I ton))! Labeling/Marking GL01 Containers are prop S rl labeled GL02 Satellite containers h. AS marked once full ave 2" GL03 Excluded recyclable materials marked properly GL04 Universal waste container properly labeled , GL05 Used oil filters marked "drained used oil filters" GL06 Date written on spent lead -acid batteries GL07 "Used Oil' marked on all used oil tanks /containers GL08 Tank marked with "haz waste" , contents, start date GL09 Empty containers marked with date emptied Treatment Transport and Disposal/Other Print and sign in this box for receipt of this report. Signature does not imply agreement -with findings, only receipt of report. GT01 Have permit/authorization to do treatment GT02 Waste sent with authorized transport en. eligible) GD01 Waste disposed of to authorized point/part GH01 Failed to properly handle appliance wastes POST INSPECTION INSTRUCTIONS: • Refer to the back of this inspection report for regulatory citations and corrective actions • Correct the violation(s) noted above by • Within 5 days of correcting all of the violations, sign and return a copy of this page to: Bakersfield Fire Dept., Prevention Services, 1501 Truxtun Avenue, California 93301 inspector Medina n� White — Prevention Services Copy 326 °3662 Signature (that all violations have been corrected as noted) Date Yellow— Business Copy FD2179 (Rev 10/21/08) Re;;ulatory Citations and Corrective Actions ill'�-r,r nth r�i: •.tl Description of violation I Re ulatory /stattttory citation I Corrective actions to be taken br minor violations marked in the "AI" cnlunuh oil fi,0110 GRo I The facility failed to obtain an EPA ID number [Title 22, CCR, 66262.12] For a California EPA ID # contact the Department of Toxic Substances Control at 1 -800 -618 -6942. For a EPA ID # call 415- 495 -NN95. Write the number in the s ace marked "EPA /D # " on the fi-ont oflhis page. GR02 The facility failed to make a waste determination 11or the noted in the [Title 22, CCR, 66262.111 Make ar determination o.0he waste based on Your knowledge (you can ase A1SDS or other documents.foi help) at- have the waste sampled and sent to a state certified laboratory for analysis•. if sans pling is conducted tell the lab to analyze for GR03 The facility did not have the name and phone number of the emergency coordinator, the location of fire extinguishers and spill control equipment, or the fire de partnpent telephone number posted next to the telephone. ITitle 22, CCR, 66262.34(d)(2)j Prepare and post the above information nest to a phone. GIZ04 Facility personnel did not demonstrate that they were familiar with proper waste handling procedures due to Title 22, CCR, 66262.34(d)(2)j Provide braining to personnel re arc ling GR05 ]'lie facility tailed to properly complete a hazardous waste manifest. Manifest # was missing [Title 22, CCR, 66262.23(a)(I )]. Correct the information on the manifest in Boxtes) I initial and elate. Submit a letter to DTSC, GISS:: P.O. Box 800 Fh l -l: Sacramento, CSI 95812 -0806 stating the manifest #, the strip date. pour EPA ID #. the Box #cant correction shade and pour signature. (Correction for more than one manifest nun; be included in the same letter GR06 Facility failed to submit a copy of the manifest to DTSC within 30 clays of shipment. [Title 22, CCR, 66262.32(a)(4)1 Mail the blue coley (?/ manifest # to: DTSC PO Bo.r 400, Sacramento. CA 95812 -0400 or a photoco v ofthe TSDF eo v to: DTSC. PO Box 3001), Sacramento. CA 95812 GR07 The facility tailed to file an exception report to DTSC after not receiving the signed TSDF copy ol•a manifest within 35 clays. [Title 22, CCR, 66262.421 Xtake a copy of the manilest and send it wish a letter to DTSC. PO Box A'A'A', Sacramento. CA 95812 stating what you are doing !o find out wltp you have not received the final, signed co v of the manifest. Include a signature and your findings while looking for the manifest in the cover letter. GROS The facility failed to have copies of receipts fir the removal of . [fISC 25160.2- Consolidated manifests/ 66266.81(a)(6)(B)- lead acid batteries /66266.130- oil filters The /hc•ilita; shall contract and request copies of receipts between et- GR09 The facility failed to complete or maintain a Land Disposal Restriction notification for manifest # ["Title 22, CCR, 66262.34(a)(4)1 The lacility shall determine if'its waste is subject to LDR requirements. and it so, ensure that a LDR is prepared and submitted with each shipment ollwaste. GRIO The facility did not submit a recycling report [H SC 25 143. 101 The./acility shall complete and submit the UPCFforin "Readable A•laterials Report ". The lorm can be found ct www.calepa.ca.gov/pub I ications/title27/defqu I ditm (Havfi-eeve. p(If) GCOI The facility failed to maintain containers holding hazardous waste in good condition. The container of was Title 22, CCR, 66262.34(a)(1)(A) 7'he contents oftne container of shall iuunechatdv be transferred to a container in good condition GCO2 The facility tailed to keep containers closed except when adding /removing waste. The container of was observed open [Title 22, CCR, 66262.34(a )(I )(A fl. . The liacility shall im inediateh; close all containers and ensure that containers remain closet/ e ee t when adding a- removing waste. GC03 'The facility is handling contaminated containers as empty when they are not. A container of was noted as not meeting the definition of empty. [Title 22, CCR, 66261.71 Ae,facility shall mark the con lei iner as hazardous waste or consolidate ill con tell ts• o/ the cotainer with a like waste and immecliateh; label the emptied container ivith the words "em tv" and the elate. GC04 The facility could not demonstrate that containers were being inspected weekly. [Title 22, CCR, 66262.34(a)(1)(A)] The facilitr shall develop and implement it plan that ensurer than all containers holding waste are inspected weekiv GC'05 The facility could not demonstrate that tanks were being inspected claily. [Title 22, CCR, 66262.34(a)(I )(A)] 77he. .facility shall keep a log showing thal tanks holding waste are inspected daily. GCO6 Containers utilizing satellite accumulation rules were not at or near the point of generation. [Title 22, CCR, 66262.34(e)(1)(A)l Thefacilih shall move the container hohling to a location that is at or near the point ofgeneration or shall enure that the waste is removed within 90/1 MI /270 days of first drop oflvaste being added, (iflhe facility; generates less than 100 14f, the clock aloes not start until 100 kg. are ,,enerated) GC 07 Containers utilizing satellite accumulation rules were not under the control of an operator. l isle 22, CCR, 66262.34(c)(I )(A)l 77te /ac•ilio- shall ensure that ono eraror is at or near the point ofaccunurlation or shall ensure that the waste is removed lvilhnh 90118012711 days of first drop ofivaste being added GC08 The facility kept more than one satellite container of at a satellite accumulation area. [Title 22, CCR, 66262.34(c)(1)] The facility; shall innmediateh; remove all bill one container from the accumulation area or shall demonstrate that it is not practical or safe to do such. GC09 ' The facility stored excluded recyclable materials not in accordance with local ordinance/tire codelhazardous materials codes [TISC 25143.9(()1 The liac•ility shall return to code by GAO The facility accumulated waste for greater than allowed time limits (Storage without a permit). A container of had an start (late of marked on it. [Title 22, CCR, 66262.34(a)] The facilitl; shall immediately (arrange for the remora( ofllie waste, and shall supply it coin; ol'the manifest or bill or lading demonstrating removal within elays. GA02 'Tile facility held satellite accumulation wastes for greater than one year. "Ville 22, CCR, 66262.34(e)(1)(B)i .See G401 above for corrections. GA03 The lacility failed to n'o perry handle contaminated containers within I vear. ITitle 22, CCR, 66261.7(1) See GA01 above for corrections. GA04 The facility held universal wastes Ion greater than one Year. ITitle 22, CCR, 66273.15(a ) or 66273..35(a)l See G1101 above. or correction. GA05 The facility held drained used oil filters for greater than 180 days /one vear. ITitle 22, CCR, 66266.130(c)(4)1 See GA01 above for corrections. GA06 The facility held lead acid batteries for greater than 130 clays/one vear. ITitle 22, CCR, 66263.81(x)(6) See G1 ill above or corrections. GL01 'file facility tailed to properly label all containers. Containers, contents and missing information are noteci on the front of this page. [Title 22, CCR, 66262.34(f)l Theflcilin shall clearly mark all containers with the following: /) the words "Hazardous waste ". 2) composition andphysical state. 3) hazard property, 4 name and address ol'!he generator. and 5) accumulation start date. GI-02 'file facility tailed to mark the (late the container was moved from the satellite accumulation area [Title 22, CCR, 66262.34(e)(I )(B)] Dc,facility shall shark all satellite accumulation with the date waste is first cackled cis well cis the date the container is Jill. GI-03 The facility I'ailed to mark tanks /container(s) of excluded recyclable materials properly [I-ISC 25143.9(a)] Tlhe truiG_s/coaailhers gfnmler•ials shall be elearlf; marked with the words "Excluded recyclable material" instead of "'hazardous waste" GI-04 •I'he tacility Iailed to murk a container of universal waste properly. [•Title 22, CCR, 66273.14 for SQI-I or 66273.34 for LQI-i 1. 77iefacilin;shcn/1 imnhediotely mark all containers holding universal waste with the words "Universal Waste- " GL05 'file facility failed to mark a container of drained used oil filters with the words "drained used oil filters ". [Title 22, CCR, 66266.130(c)(3)1 Theliacilirn shall inrr k all filler containers with the words "drained used oil llters" GL06 The facility failed to mark the date on which the battery was received. 'rifle 22, CCR, 66266.8 1 (a)(6)(D)l The ficility shall v mark the dare on each baaerv. C.L07 The facility Railed to mark a tank /container of used oil destined 1'or recycling with the words "used oil" [DISC 25143.9(a)] Clearly mark all ranks and containers with the words "used oil ". GL08 The I'acility failed to mark the tank of with the [Title 22, CCR, 66234(t)j The /hcilimshall clearly mark the tank with G1_09 The facility failed to mark contaminated container's with the date emptied. ITitle 22, CCR, 66261.7(t)l Clecti1v nna•kall containers with the date emptied. GI-101 The facility failed to remove from an appliance prior to crushing, baling, shredding, salving or disposing of the appliance [I ISC 2521 (a)]. Tire fiteilihl must submit to DTSC an application to be certified as a •'Certified A p pliance Recvcler" Gr01 The facility tailed to obtain a permit or other authorization for treaunent ol•hazardous waste. 1-1 SC 25189.5(d) GT02 The lacility failed to use a registered transporter/used a transporter or consolidated waste when thcv were not eligible I -ISC 25165(a)/25160 GDO I The lacility disposed of hazadous waste at an unauthorized point. 11-ISC 25189.5(a) ill'�-r,r nth r�i: •.tl 0 HAZARDOUS'WASTE BAKERSFIELD FIRE DEPARTMENT UNIFIED PROGRAM CONSOLIDATED FORMS Prevention Services a 1501 Truxtun Ave 1s'r FLR HAZARDOU6'WASTE GENERATOR �A_Rt� Bakersfield, CA 93301 INSPECTION REPORT Phone: 661- 326 -3979 • Fax: 661 - 852 -2171 Facility Name~ _' / ,� . "2 Date /� Site Address /L,1 7 � Time In �� d Y�'r� Time Out Owner /Operator Phone Mi�c Type of Inspection Inspection Consolidation EPA ID # r 1 i "> ❑ Routine /❑ Re- inspection/Follow -up "'�6 Combined Routine Inspection ❑ Joint Inspection ❑ Complaint ❑ Focused ❑ Other 0 or Multi -Media Inspection CUPA Facility ID# ` 1 CONSENT TO INSPECT GRANTED BY (Name / Title): ti'"'' r! r r Inspection may involve'obtaining photographs, review and copying of records, and determination of compliance with hazardous waste handling requirements. I - Class 1 Violation. 11 - Class 11 Violation, M - Minor Violation Paee of 1 II M Code HAZARDOUS WASTE REQUIREMENTS Y N N/A COMMENTS/NOTES /DOCUMENT(S) REVIEWED MISSING INFORMATION/ UNRESOLVED ISSUES Recordkee in documentation GR01 Generator has an EPA ID number GR02 Hazardous waste determination made for all wastes ❑ Anal sis.)o Generator Knowledge GR03 Contingency Ian information posted near phone GR04 Facility personnel demonstrate training/awareness ?=, GR05 Manifests/Consolidated Manifest receipts complete X GR06 Blue co (s) of manifest mailed to DTSC GR07 TSDF signed copy of manifest available Win 35 days of waste shipment ; ` GR08 Bills of Lading/receipts available GR09 LDRs available and complete X GRID Onsite recycling reported using UPCF Container /tank management GC01 Containers are in good condition GCO2 Containers are closed except when adding/removing GC03 Empty containers are em pt Y, GC04 Containers inspected week) GC05 Tanks inspected daily�C GC06 Satellite containers at or near point of generation ^ GC07 Satellite containers under control of operator GC08 One container per wastestream at satellite area ti GC09 Exclude recyclable materials stored in accordance with local ordinance/hazardous materials codes A. Accumulation Time Limits GA01 Waste is accumulated not more than 90/180/270 }L ;77 t ' r, .. c /I GA02 Satellite wastes accumulated for less than I year 7e GA03 Empty containers managed within one year jf GA04 Universal waste accumulated less than one year k GA05 Used oil filters offsite within 180 (I year if <1 ton) GA06 Pb -acid batteries offsite within 180 (I yr. if < l ton) Labeling/Marking GLOI Containers are properly labeled GL02 Satellite containers have 2 ASD marked once full GL03 Excluded recyclable materials marked properly Js. GL04 Universal waste container properly labeled GL05 Used oil filters marked "drained used oil filters" X. GL06 Date written on spent lead -acid batteries GL07 "Used Oil' marked on all used oil tanks /containers f GLO8 Tank marked with "haz waste" , contents, start date �. GUN Empty containers marked with date emptied K Treatment Transport and Disposal/Other Print and sign in this box for receipt of this report. Signature does not imply agreement with findings, only receipt of report. �l GT01 orization to do treatment GT02 Waste sent with authorized transport (en. eligible) GD01 Waste dis used of to authorized point/party GH01 Failed to properly handle appliance wastes POST INSPECTION INSTRUCTIONS: • Refer to the back of this inspection report for regulatory citations and corrective actions • Correct the violation(s) noted above by • Within 5 days of correcting all of the violations, sign and return a copy of this page to: Bakersfield Fire Dept., Prevention Services, 1501 Truxtun Avenue, California 93301 Inspector Medina 326 -3632 White — Prevention Services Copy Signature (that all violations have been corrected as noted) Date Yellow— Business Copy FD2179 (Rev 10/21/08) Regulatory Citations and Corrective Actions ' l):' i ll .. :''I I Description of violation I Re gulatory /statutory citation Cbrrec•tve actions to be taken for minor violations (,narked in the "M" column on front) GRo I The facility failed to obtain an EPA ID number [Tide 22, CCR, 66262.121 For a Caliloraia ERR ID # contact t+e Depannent q/ Toxic Substances Control ai 1 -800 -618-0942. For a EPA 1D # call 415 - 495- 8S'95. 11 %rite the number in the s ac:e marked "EP.4 1D # all the fi-ont ol'tais page. GR02 The facility failed( to make a waste determination for the noted in the [Title 22, CCR, 66262.11 ] klake a determination ol'the waste based on your knondeclge (you can use rt1SD.S or other elocanentsJor helm) or have the waste scan led and sent to a slue certilied laboratory for unalvsis. itsani piing is conducted tell the lab to analyze for GR03 The facility clid not have the name and phone number ol'Ihe emergency coordinator, the location of fire extinguishers and spill control equipment, or the fire department telephone number posted next to the telephone. 'Title 22, CCR, 66262.34(d)(2) Prepare and post the above inlornurtion next to ti hone. GR04 Facility personnel did not demonstrate that they were familiar with proper waste handling procedures due to Title 22, CCR, 66262.34(d)(2)j Provide training to personnel regarding GR05 The facility failed to properly complete a hazardous waste manifest. Manifest # was missing [Title 22, C'CR, 66262.23(a)(1)]. Correct rte ii jorrnatiora otn tlne ntauilert in Box(es) initial and date. Submit a letter to DISC. GISS:: P.O. Box 8116 1--h-1 -1: Sacramento. CA 95812 -0806 stating the manifest #, the ship dale, Your EP.4 ID #• the Box # aad correction made and i -our signcrrure. (Correction /or more than one manifest man; be included in (lie some peter) GIZ06 Facility failed to submit a copy ofthe manifest to DTSC within 30 days ofshipment. [Title 22, CCR, 66262.32(x)(4)] itlail the hluc colrn gl'rnanilest # to: DTSC. PO Boa 400, Sacramento. CA 95812 - 0400 or a photocn n; ofthe TSDF co v to: DTSC. PO Box 3000. Sacramento. C.4 95812 GR07 The facility failed to file an exception report to DTSC alter not receiving the signed TSDF copy of a manifest within 35 days. [Title 22, CCR, 66262.421 Make a color ofthe manifest and send it with a letter to DTSC. PO Box XXV Sacramento, CA 95812 slating what you are doing toJind out it h.v.vou have not received tine linal. signed coot otdne maniles(. Include a signatave aunt vour findings while looking for rile manifest in the cover letter. GROS The facility failed to have copies of receipts for the removal of . [TISC 25160?- Consolidated nwnifests/ 66266.31(a)(6)(B)- lead acid batteries /66266.130- oil hitersl The larcilin; shall coalact and request copies ol'receipts between cr GR09 The facility tailed to complete or maintain a Land Disposal Restriction notification for manifest # ['title 22, CCR, 66262.34(a)(4)l The facility shall determine it'its waste is subject to LDR requirements, and it so, ensure that a LDR is pre pared and submitted with each shipment ol'ivtiste. GR10 The facility diet not submit a recycling report [HSC 25143.10{ TheJitcility shall complete and submit the UPCFfnr in "Recy duble Materials Report ". The form can be found at www.cale a.ca.arov/ ub] ications /title27 /default.htm (Hiw/i•eeve.adi) GC'01 The facility tailed to maintain containers holding haZU1 -d0l1$ waste in good condition. The container of was 1'itle 22, C'C'R, 66262.34(a)(1)(A) The c•ottenrs oldie container of stroll immediauel- be transfered to a container in good condition GC'02 The facility failed to keep containers closed except when adding /removing waste. The container of was observed open ITille 72, CCR, 66262.34(a)(1)(A) . 77+e laciliry shall inunediaael- close all containers and ensure that containers remain closed except when adding or reoto i -ing waste. GC'03 The facility is handling contaminated containers as empty when they are not. A container of was noted as not meeting the definition of empty. [Title 22, CCR, 66261.71 TheJiicility shall mark the container cis hazardous waste or consolidate the contents ofthe container ivilh a like waste and ihnmediatelv label the emptied container with the words "em )tv "cant the date. GC04 The facility could not demonstrate that containers were being inspected weekly. ITitle 22, CCR, 66262.34(a)(1)(A)] TheJacililp shall develop mild implement a plan that ensues that all containers holding waste are inspected weekly GC'05 The facility could not demonstrate that tanks were being inspected daily. [Title 22, CCR, 66262.34(a)(1)(A)J The /ircilin; ,shall keep a log showing that tanks holding waste are inspected dai /v. GC06 Containers utilizing satellite accumulation rules were not at or near the point of generation. I.Title 22, CCR, 66262.34(e)(1)(A)l The /uci /in +shut/ more the container holding to a location than is art or near the point otgeneration or shall ensure that the waste is realoved within 9(1118(1 1270 clans of lust drop ofivaste being addeel. (ifihe liaciliw vnerates less than /00 kg. the clock does not start ratil /00 kg. are �enercued) GC'07 Containers utilizing satellite accumulation rules were not under the control of an operator. ['Title 22, CCR, 66262.34(e)(1)(A)l The /ncilin; shall ensure drat an operator is at or near the point of accumulation or shoal/ ensure that the waste is removed within 9011801270 darns of first drop ofivaste being cadeletl GC03 The facility kept more than one satellite container of at a satellite accunnllalion area. [Title 22, CCR, 66262.34(e)(I )l Theflcilin; shall immediately remove all but one container front the accumulation area or shall demonstrate that it is not practical or sale to do such. CIC09 The facility stored excluded recyclable materials not in accordance with local ordinance /lire code /hazardous materials codes [fISC 25143.9(c)l Thefiacilitv shall return to erode by GAO The facility accumulated waste for greater than allowed time limits (Storage without a permit). A container of had an stall date of marked on it. [Title 22, CCR, 66262.34(a)l TheJacili(p shall immediately arrange .fbr the removal ql the waste, and shall supply a cujpv ofthe manilest or bill or lading demonsiratin , removal within days. GA02 The facility held satellite accumulation wastes for greater than one vear. jTiilc 22, CCR, 66262.34(c)(1)(B)l See GA01 above for corrections. GA03 The facility failed to properly handle contaminated containers within I vear. ITitle 22, CCR, 66261.7(1 )1 See 0401 above for corrections. GA04 The facility held universal wastes for greater than one vear. ITille 22, CCR, 66273.15(a) of 66273..35(x) I See G2101 above for corrections. GA05 The facility held drained used oil filters for greater than 130 days /one vear. ITitle 22, CCR, 66266.130(c)(4) .See G1101 above for corrections. GA06 The lacilily held lead acid batteries for greater than 130 days /one vear. Title 22, CCR, 66268.8 l(a)(6)1 See G1101 above for corrections. GL,01 The facility failed to properly label all containers. Containers, contents and missing inlormalion are noted on the front of this page. ITitle 22, CCR, 66262.34(111 TheJiacility shall clearly mark all containers )with tine following: 1) the words "hlazardous waste ". 2) c•onnpos•ilion crud plrnsical state, 3) hazard ro perm. 4) name and address ofthe ,generator. and 5) accumulation start date. GI-02 The facility tailed to mark the date the comainer was moved from the satellite accumulation area [Title 22, CCR, 66262.34(c)(I )(B)l Thefcac•i/i(v shall nark till satellite accumulation with the duce waste is first added cis well as• the elate the container is Ball. Col-03 The facility failed to mark tanks /container(s) of excluded recyclable materials properly [DISC 25143.9(a)1 The tankslcontainer•s• ol'inaterials shall be clearly larked with the words "Esclali'd recyclable material" instead of " hazardous t'as'te ". GI-04 The facility failed to mark a container of universal waste properly. [Tillc 22, CCR, 66273.14 for SQI-I or 66273.34 Ibr LQH 1. Thefarc•ility shall imntedlately mark all containers holding universal waste with the words "Universal Waste- " GI-05 The facility failed to mark a container of (trained used oil filters with the words "drained used oil lilters ". [Title 22, CCR, 66266.130(c)(3)l Thefircility shall mark all filter containers with the words "drained used oil filters ". GI-06 The facility failed to mark the date on which the battery was received. ITitle 22, CCR, 66266.8 1 (a)(6)(D)l The laacility shall v marl.' the date on each baterv. GL07 The facility failed to nark a tank /container of used oil destined for recycling with the words "used oil" I HSC 25143.9(a),l Clearly mark all tanks caul containers with the wads "used oil ". GI-03 The facility failed to mark the tank of with the 1'title 22, CCR, 66234(11,1 The facility shall clearly mark the lank with GL09 The facility failed to mark contaminated containers with the date ell plied. ITitle 22, CCR, 66261.7(8 C /each- nuukal! cauuiners n•ith the date ent pried. GI101 The facility tailed to remove from an appliance prior to crushing, baling, shredding, sawing or disposing ofthe appliance [DISC 25212(a) l. The lac•i /ity must submit to D7SC an application to be certifier/ as a "Certified Appliance Reevcler" GT01 The facility failed to obtain a permit ov other authorization for treatment of hazardous waste. IiSC 25189.5(cl) G 102 The facility failed It) Use a reklCtered trans porterbise'd a transporter or Consolidated waste when they were not eligible -I -ISC 25165(a)/25160 GD01 the facility disposed of hazarcloU5 waste at all UllaUlh01'IZed point. HSC 25139.5(x) ' l):' i ll .. :''I I