HomeMy WebLinkAboutHAZ WASTE GENERATOR INSPECTION REPORT 8-11-11HAZARDOUS WASTE BAKERSFIELD FIRE DEPARTMENT
UNIFIED PROGRAM CONSOLIDATED FORMS Prevention Services
1501 Truxtun Ave 1sT FLR
HAZARDOUS WASTE GENERATOR o r Bakersfield, CA 93301
INSPECTION REPORT I Phone: 661 - 326 -3979 • Fax: 661 - 852 -2171
Facility Name
Site Address
Date
Time In 3r ��� Time Out
Owner /Operator Phone Misc.
Type of Inspection Inspection Consolidation EPA ID # CAI 050 G &
❑ Routine ❑ Re- inspection/Follow -up Combined Routine Inspection ❑ Joint Inspection ❑ Complaint ❑ Focused ❑ Other
❑ Integrated or Multi -Media Inspection - CUPA Facility 1D#
i
CONSENT TO INSPECT GRANTED BY (Name / Title): rr) V" /"t V- —,I r'A V:�t° 1—
Inspection may involve obtaining photographs, review and copying of records, and determination of compliance with hazardous waste handling requirements.
[-Class I Violation, 11 -Class 11 Violation, M -Minor Violation
Page of
1
J_
M
HAZARDOUS WASTE REQUIREMENTS
Code I
Y
N
N/A
COMMENTS /NOTES/DOCUMENT(S) REVIEWED
MISSING INFORMATION/ UNRESOLVED ISSUES
Recordkee in documentation
GR01
Generator has an EPA ID number
GR02
Hazardous waste determination made for all wastes
❑ Anal sisV Generator Knowled a
.!
GR03
Contin enc plan information posted near phone
GR04
Facility personnel demonstrate training/awareness
GR05
Mani fests/Consolidated Manifest receipts complete
GR06
Blue co (s) of manifest mailed to Disc
GR07
TSDF signed copy of manifest available Win 35
da s of waste shipment
GR08
Bills of Ladin recei is available
�{
GR09
LDRs available and complete
GR 10
1 Onsite recycling reported using UPCF
ti
Container /tank management
GC01
Containers are in good condition
GCO2
Containers are closed except when adding/removing
GC03
Empty containers are empty
GC04
Containers inspected week)
GC05
Tanks inspected daily
GC06
Satellite containers at or near point of generation
GC07
Satellite containers under control of operator
GC08
One container per wastestream at satellite area
i(
GC09
Exclude recyclable materials stored in accordance
with local ordinance/hazardous materials codes
n
Accumulation Time Limits
GA01
Waste is accumulated not more than 90/180/270
a zfLT lam% p
GA02
Satellite wastes accumulated for less than 1 year
GA03
Empty containers managed within one year
GA04
Universal waste accumulated less than one year
X
GA05
Used oil filters offsite within 180 (l year if <1 ton)
GA06
Pb -acid batteries offsite within 180 (1 yr. if < I ton))!
Labeling/Marking
GL01
Containers are prop S rl labeled
GL02
Satellite containers h. AS marked once full
ave 2"
GL03
Excluded recyclable materials marked properly
GL04
Universal waste container properly labeled
,
GL05
Used oil filters marked "drained used oil filters"
GL06
Date written on spent lead -acid batteries
GL07
"Used Oil' marked on all used oil tanks /containers
GL08
Tank marked with "haz waste" , contents, start date
GL09
Empty containers marked with date emptied
Treatment Transport and Disposal/Other
Print and sign in this box for receipt of this report. Signature does
not imply agreement -with findings, only receipt of report.
GT01
Have permit/authorization to do treatment
GT02
Waste sent with authorized transport en. eligible)
GD01
Waste disposed of to authorized point/part
GH01
Failed to properly handle appliance wastes
POST INSPECTION INSTRUCTIONS:
• Refer to the back of this inspection report for regulatory citations and corrective actions
• Correct the violation(s) noted above by
• Within 5 days of correcting all of the violations, sign and return a copy of this page to:
Bakersfield Fire Dept., Prevention Services, 1501 Truxtun Avenue, California 93301
inspector Medina
n�
White — Prevention Services Copy
326 °3662
Signature (that all violations have been corrected as noted)
Date
Yellow— Business Copy
FD2179 (Rev 10/21/08)
Re;;ulatory Citations and Corrective Actions
ill'�-r,r nth r�i: •.tl
Description of violation I Re ulatory /stattttory citation I Corrective actions to be taken br minor violations marked in the "AI" cnlunuh oil fi,0110
GRo I
The facility failed to obtain an EPA ID number [Title 22, CCR, 66262.12] For a California EPA ID # contact the Department of Toxic Substances Control at
1 -800 -618 -6942. For a EPA ID # call 415- 495 -NN95. Write the number in the s ace marked "EPA /D # " on the fi-ont oflhis page.
GR02
The facility failed to make a waste determination 11or the noted in the
[Title 22, CCR, 66262.111 Make ar determination o.0he waste based on Your knowledge (you can ase A1SDS or other documents.foi help) at- have the waste
sampled and sent to a state certified laboratory for analysis•. if sans pling is conducted tell the lab to analyze for
GR03
The facility did not have the name and phone number of the emergency coordinator, the location of fire extinguishers and spill control equipment, or the fire
de partnpent telephone number posted next to the telephone. ITitle 22, CCR, 66262.34(d)(2)j Prepare and post the above information nest to a phone.
GIZ04
Facility personnel did not demonstrate that they were familiar with proper waste handling procedures due to
Title 22, CCR, 66262.34(d)(2)j Provide braining to personnel re arc ling
GR05
]'lie facility tailed to properly complete a hazardous waste manifest. Manifest # was missing
[Title 22, CCR, 66262.23(a)(I )]. Correct the information on the manifest in Boxtes) I initial and elate. Submit a letter to DTSC, GISS:: P.O.
Box 800 Fh l -l: Sacramento, CSI 95812 -0806 stating the manifest #, the strip date. pour EPA ID #. the Box #cant correction shade and pour signature.
(Correction for more than one manifest nun; be included in the same letter
GR06
Facility failed to submit a copy of the manifest to DTSC within 30 clays of shipment. [Title 22, CCR, 66262.32(a)(4)1 Mail the blue coley (?/ manifest
# to: DTSC PO Bo.r 400, Sacramento. CA 95812 -0400 or a photoco v ofthe TSDF eo v to: DTSC. PO Box 3001), Sacramento. CA 95812
GR07
The facility tailed to file an exception report to DTSC after not receiving the signed TSDF copy ol•a manifest within 35 clays. [Title 22, CCR, 66262.421
Xtake a copy of the manilest and send it wish a letter to DTSC. PO Box A'A'A', Sacramento. CA 95812 stating what you are doing !o find out wltp you have not
received the final, signed co v of the manifest. Include a signature and your findings while looking for the manifest in the cover letter.
GROS
The facility failed to have copies of receipts fir the removal of . [fISC 25160.2- Consolidated manifests/ 66266.81(a)(6)(B)-
lead acid batteries /66266.130- oil filters The /hc•ilita; shall contract and request copies of receipts between et-
GR09
The facility failed to complete or maintain a Land Disposal Restriction notification for manifest # ["Title 22, CCR, 66262.34(a)(4)1
The lacility shall determine if'its waste is subject to LDR requirements. and it so, ensure that a LDR is prepared and submitted with each shipment ollwaste.
GRIO
The facility did not submit a recycling report [H SC 25 143. 101 The./acility shall complete and submit the UPCFforin "Readable A•laterials Report ". The
lorm can be found ct www.calepa.ca.gov/pub I ications/title27/defqu I ditm (Havfi-eeve. p(If)
GCOI
The facility failed to maintain containers holding hazardous waste in good condition. The container of was
Title 22, CCR, 66262.34(a)(1)(A) 7'he contents oftne container of shall iuunechatdv be transferred to a container in good condition
GCO2
The facility tailed to keep containers closed except when adding /removing waste. The container of was observed open [Title 22, CCR,
66262.34(a )(I )(A fl. . The liacility shall im inediateh; close all containers and ensure that containers remain closet/ e ee t when adding a- removing waste.
GC03
'The facility is handling contaminated containers as empty when they are not. A container of was noted as not meeting the definition of
empty. [Title 22, CCR, 66261.71 Ae,facility shall mark the con lei iner as hazardous waste or consolidate ill con tell ts• o/ the cotainer
with a like waste and immecliateh; label the emptied container ivith the words "em tv" and the elate.
GC04
The facility could not demonstrate that containers were being inspected weekly. [Title 22, CCR, 66262.34(a)(1)(A)] The facilitr shall develop and implement
it plan that ensurer than all containers holding waste are inspected weekiv
GC'05
The facility could not demonstrate that tanks were being inspected claily. [Title 22, CCR, 66262.34(a)(I )(A)] 77he. .facility shall keep a log showing thal tanks
holding waste are inspected daily.
GCO6
Containers utilizing satellite accumulation rules were not at or near the point of generation. [Title 22, CCR, 66262.34(e)(1)(A)l Thefacilih shall move the
container hohling to a location that is at or near the point ofgeneration or shall enure that the waste is removed within 90/1 MI /270
days of first drop oflvaste being added, (iflhe facility; generates less than 100 14f, the clock aloes not start until 100 kg. are ,,enerated)
GC 07
Containers utilizing satellite accumulation rules were not under the control of an operator. l isle 22, CCR, 66262.34(c)(I )(A)l 77te /ac•ilio- shall ensure that
ono eraror is at or near the point ofaccunurlation or shall ensure that the waste is removed lvilhnh 90118012711 days of first drop ofivaste being added
GC08
The facility kept more than one satellite container of at a satellite accumulation area. [Title 22, CCR, 66262.34(c)(1)] The facility;
shall innmediateh; remove all bill one container from the accumulation area or shall demonstrate that it is not practical or safe to do such.
GC09
' The facility stored excluded recyclable materials not in accordance with local ordinance/tire codelhazardous materials codes [TISC 25143.9(()1 The liac•ility
shall return to code by
GAO
The facility accumulated waste for greater than allowed time limits (Storage without a permit). A container of had an start (late of
marked on it. [Title 22, CCR, 66262.34(a)] The facilitl; shall immediately (arrange for the remora( ofllie waste, and shall supply it coin; ol'the manifest or bill
or lading demonstrating removal within elays.
GA02
'Tile facility held satellite accumulation wastes for greater than one year. "Ville 22, CCR, 66262.34(e)(1)(B)i .See G401 above for corrections.
GA03
The lacility failed to n'o perry handle contaminated containers within I vear. ITitle 22, CCR, 66261.7(1) See GA01 above for corrections.
GA04
The facility held universal wastes Ion greater than one Year. ITitle 22, CCR, 66273.15(a ) or 66273..35(a)l See G1101 above. or correction.
GA05
The facility held drained used oil filters for greater than 180 days /one vear. ITitle 22, CCR, 66266.130(c)(4)1 See GA01 above for corrections.
GA06
The facility held lead acid batteries for greater than 130 clays/one vear. ITitle 22, CCR, 66263.81(x)(6) See G1 ill above or corrections.
GL01
'file facility tailed to properly label all containers. Containers, contents and missing information are noteci on the front of this page. [Title 22, CCR,
66262.34(f)l Theflcilin shall clearly mark all containers with the following: /) the words "Hazardous waste ". 2) composition andphysical state. 3) hazard
property, 4 name and address ol'!he generator. and 5) accumulation start date.
GI-02
'file facility tailed to mark the (late the container was moved from the satellite accumulation area [Title 22, CCR, 66262.34(e)(I )(B)] Dc,facility shall shark
all satellite accumulation with the date waste is first cackled cis well cis the date the container is Jill.
GI-03
The facility I'ailed to mark tanks /container(s) of excluded recyclable materials properly [I-ISC 25143.9(a)] Tlhe truiG_s/coaailhers gfnmler•ials shall be elearlf;
marked with the words "Excluded recyclable material" instead of "'hazardous waste"
GI-04
•I'he tacility Iailed to murk a container of universal waste properly. [•Title 22, CCR, 66273.14 for SQI-I or 66273.34 for LQI-i 1. 77iefacilin;shcn/1 imnhediotely
mark all containers holding universal waste with the words "Universal Waste- "
GL05
'file facility failed to mark a container of drained used oil filters with the words "drained used oil filters ". [Title 22, CCR, 66266.130(c)(3)1 Theliacilirn shall
inrr k all filler containers with the words "drained used oil llters"
GL06
The facility failed to mark the date on which the battery was received. 'rifle 22, CCR, 66266.8 1 (a)(6)(D)l The ficility shall v mark the dare on each baaerv.
C.L07
The facility Railed to mark a tank /container of used oil destined 1'or recycling with the words "used oil" [DISC 25143.9(a)] Clearly mark all ranks and
containers with the words "used oil ".
GL08
The I'acility failed to mark the tank of with the [Title 22, CCR, 66234(t)j The /hcilimshall
clearly mark the tank with
G1_09
The facility failed to mark contaminated container's with the date emptied. ITitle 22, CCR, 66261.7(t)l Clecti1v nna•kall containers with the date emptied.
GI-101
The facility failed to remove from an appliance prior to crushing, baling, shredding, salving or disposing of the appliance [I ISC
2521 (a)]. Tire fiteilihl must submit to DTSC an application to be certified as a •'Certified A p pliance Recvcler"
Gr01
The facility tailed to obtain a permit or other authorization for treaunent ol•hazardous waste. 1-1 SC 25189.5(d)
GT02
The lacility failed to use a registered transporter/used a transporter or consolidated waste when thcv were not eligible I -ISC 25165(a)/25160
GDO I
The lacility disposed of hazadous waste at an unauthorized point. 11-ISC 25189.5(a)
ill'�-r,r nth r�i: •.tl
0
HAZARDOUS'WASTE BAKERSFIELD FIRE DEPARTMENT
UNIFIED PROGRAM CONSOLIDATED FORMS Prevention Services
a 1501 Truxtun Ave 1s'r FLR
HAZARDOU6'WASTE GENERATOR �A_Rt� Bakersfield, CA 93301
INSPECTION REPORT Phone: 661- 326 -3979 • Fax: 661 - 852 -2171
Facility Name~ _' / ,� . "2 Date
/� Site Address /L,1 7 � Time In �� d Y�'r� Time Out
Owner /Operator Phone Mi�c
Type of Inspection Inspection Consolidation EPA ID # r 1 i ">
❑ Routine /❑ Re- inspection/Follow -up "'�6 Combined Routine Inspection ❑ Joint Inspection ❑ Complaint ❑ Focused ❑ Other
0 or Multi -Media Inspection CUPA Facility ID#
` 1 CONSENT TO INSPECT GRANTED BY (Name / Title): ti'"'' r! r r
Inspection may involve'obtaining photographs, review and copying of records, and determination of compliance with hazardous waste handling requirements.
I - Class 1 Violation. 11 - Class 11 Violation, M - Minor Violation Paee of
1
II
M
Code
HAZARDOUS WASTE REQUIREMENTS
Y
N
N/A
COMMENTS/NOTES /DOCUMENT(S) REVIEWED
MISSING INFORMATION/ UNRESOLVED ISSUES
Recordkee in documentation
GR01
Generator has an EPA ID number
GR02
Hazardous waste determination made for all wastes
❑ Anal sis.)o Generator Knowledge
GR03
Contingency Ian information posted near phone
GR04
Facility personnel demonstrate training/awareness
?=,
GR05
Manifests/Consolidated Manifest receipts complete
X
GR06
Blue co (s) of manifest mailed to DTSC
GR07
TSDF signed copy of manifest available Win 35
days of waste shipment
;
`
GR08
Bills of Lading/receipts available
GR09
LDRs available and complete
X
GRID
Onsite recycling reported using UPCF
Container /tank management
GC01
Containers are in good condition
GCO2
Containers are closed except when adding/removing
GC03
Empty containers are em pt
Y,
GC04
Containers inspected week)
GC05
Tanks inspected daily�C
GC06
Satellite containers at or near point of generation
^
GC07
Satellite containers under control of operator
GC08
One container per wastestream at satellite area
ti
GC09
Exclude recyclable materials stored in accordance
with local ordinance/hazardous materials codes
A.
Accumulation Time Limits
GA01
Waste is accumulated not more than 90/180/270
}L
;77 t ' r, .. c /I
GA02
Satellite wastes accumulated for less than I year
7e
GA03
Empty containers managed within one year
jf
GA04
Universal waste accumulated less than one year
k
GA05
Used oil filters offsite within 180 (I year if <1 ton)
GA06
Pb -acid batteries offsite within 180 (I yr. if < l ton)
Labeling/Marking
GLOI
Containers are properly labeled
GL02
Satellite containers have 2 ASD marked once full
GL03
Excluded recyclable materials marked properly
Js.
GL04
Universal waste container properly labeled
GL05
Used oil filters marked "drained used oil filters"
X.
GL06
Date written on spent lead -acid batteries
GL07
"Used Oil' marked on all used oil tanks /containers
f
GLO8
Tank marked with "haz waste" , contents, start date
�.
GUN
Empty containers marked with date emptied
K
Treatment Transport and Disposal/Other
Print and sign in this box for receipt of this report. Signature does
not imply agreement with findings, only receipt of report.
�l
GT01
orization to do treatment
GT02
Waste sent with authorized transport (en. eligible)
GD01
Waste dis used of to authorized point/party
GH01
Failed to properly handle appliance wastes
POST INSPECTION INSTRUCTIONS:
• Refer to the back of this inspection report for regulatory citations and corrective actions
• Correct the violation(s) noted above by
• Within 5 days of correcting all of the violations, sign and return a copy of this page to:
Bakersfield Fire Dept., Prevention Services, 1501 Truxtun Avenue, California 93301
Inspector Medina
326 -3632
White — Prevention Services Copy
Signature (that all violations have been corrected as noted)
Date
Yellow— Business Copy
FD2179 (Rev 10/21/08)
Regulatory Citations and Corrective Actions
' l):' i ll .. :''I I
Description of violation I Re gulatory /statutory citation Cbrrec•tve actions to be taken for minor violations (,narked in the "M" column on front)
GRo I
The facility failed to obtain an EPA ID number [Tide 22, CCR, 66262.121 For a Caliloraia ERR ID # contact t+e Depannent q/ Toxic Substances Control ai
1 -800 -618-0942. For a EPA 1D # call 415 - 495- 8S'95. 11 %rite the number in the s ac:e marked "EP.4 1D # all the fi-ont ol'tais page.
GR02
The facility failed( to make a waste determination for the noted in the
[Title 22, CCR, 66262.11 ] klake a determination ol'the waste based on your knondeclge (you can use rt1SD.S or other elocanentsJor helm) or have the waste
scan led and sent to a slue certilied laboratory for unalvsis. itsani piing is conducted tell the lab to analyze for
GR03
The facility clid not have the name and phone number ol'Ihe emergency coordinator, the location of fire extinguishers and spill control equipment, or the fire
department telephone number posted next to the telephone. 'Title 22, CCR, 66262.34(d)(2) Prepare and post the above inlornurtion next to ti hone.
GR04
Facility personnel did not demonstrate that they were familiar with proper waste handling procedures due to
Title 22, CCR, 66262.34(d)(2)j Provide training to personnel regarding
GR05
The facility failed to properly complete a hazardous waste manifest. Manifest # was missing
[Title 22, C'CR, 66262.23(a)(1)]. Correct rte ii jorrnatiora otn tlne ntauilert in Box(es) initial and date. Submit a letter to DISC. GISS:: P.O.
Box 8116 1--h-1 -1: Sacramento. CA 95812 -0806 stating the manifest #, the ship dale, Your EP.4 ID #• the Box # aad correction made and i -our signcrrure.
(Correction /or more than one manifest man; be included in (lie some peter)
GIZ06
Facility failed to submit a copy ofthe manifest to DTSC within 30 days ofshipment. [Title 22, CCR, 66262.32(x)(4)] itlail the hluc colrn gl'rnanilest
# to: DTSC. PO Boa 400, Sacramento. CA 95812 - 0400 or a photocn n; ofthe TSDF co v to: DTSC. PO Box 3000. Sacramento. C.4 95812
GR07
The facility failed to file an exception report to DTSC alter not receiving the signed TSDF copy of a manifest within 35 days. [Title 22, CCR, 66262.421
Make a color ofthe manifest and send it with a letter to DTSC. PO Box XXV Sacramento, CA 95812 slating what you are doing toJind out it h.v.vou have not
received tine linal. signed coot otdne maniles(. Include a signatave aunt vour findings while looking for rile manifest in the cover letter.
GROS
The facility failed to have copies of receipts for the removal of . [TISC 25160?- Consolidated nwnifests/ 66266.31(a)(6)(B)-
lead acid batteries /66266.130- oil hitersl The larcilin; shall coalact and request copies ol'receipts between cr
GR09
The facility tailed to complete or maintain a Land Disposal Restriction notification for manifest # ['title 22, CCR, 66262.34(a)(4)l
The facility shall determine it'its waste is subject to LDR requirements, and it so, ensure that a LDR is pre pared and submitted with each shipment ol'ivtiste.
GR10
The facility diet not submit a recycling report [HSC 25143.10{ TheJitcility shall complete and submit the UPCFfnr in "Recy duble Materials Report ". The
form can be found at www.cale a.ca.arov/ ub] ications /title27 /default.htm (Hiw/i•eeve.adi)
GC'01
The facility tailed to maintain containers holding haZU1 -d0l1$ waste in good condition. The container of was
1'itle 22, C'C'R, 66262.34(a)(1)(A) The c•ottenrs oldie container of stroll immediauel- be transfered to a container in good condition
GC'02
The facility failed to keep containers closed except when adding /removing waste. The container of was observed open ITille 72, CCR,
66262.34(a)(1)(A) . 77+e laciliry shall inunediaael- close all containers and ensure that containers remain closed except when adding or reoto i -ing waste.
GC'03
The facility is handling contaminated containers as empty when they are not. A container of was noted as not meeting the definition of
empty. [Title 22, CCR, 66261.71 TheJiicility shall mark the container cis hazardous waste or consolidate the contents ofthe container
ivilh a like waste and ihnmediatelv label the emptied container with the words "em )tv "cant the date.
GC04
The facility could not demonstrate that containers were being inspected weekly. ITitle 22, CCR, 66262.34(a)(1)(A)] TheJacililp shall develop mild implement
a plan that ensues that all containers holding waste are inspected weekly
GC'05
The facility could not demonstrate that tanks were being inspected daily. [Title 22, CCR, 66262.34(a)(1)(A)J The /ircilin; ,shall keep a log showing that tanks
holding waste are inspected dai /v.
GC06
Containers utilizing satellite accumulation rules were not at or near the point of generation. I.Title 22, CCR, 66262.34(e)(1)(A)l The /uci /in +shut/ more the
container holding to a location than is art or near the point otgeneration or shall ensure that the waste is realoved within 9(1118(1 1270
clans of lust drop ofivaste being addeel. (ifihe liaciliw vnerates less than /00 kg. the clock does not start ratil /00 kg. are �enercued)
GC'07
Containers utilizing satellite accumulation rules were not under the control of an operator. ['Title 22, CCR, 66262.34(e)(1)(A)l The /ncilin; shall ensure drat
an operator is at or near the point of accumulation or shoal/ ensure that the waste is removed within 9011801270 darns of first drop ofivaste being cadeletl
GC03
The facility kept more than one satellite container of at a satellite accunnllalion area. [Title 22, CCR, 66262.34(e)(I )l Theflcilin;
shall immediately remove all but one container front the accumulation area or shall demonstrate that it is not practical or sale to do such.
CIC09
The facility stored excluded recyclable materials not in accordance with local ordinance /lire code /hazardous materials codes [fISC 25143.9(c)l Thefiacilitv
shall return to erode by
GAO
The facility accumulated waste for greater than allowed time limits (Storage without a permit). A container of had an stall date of
marked on it. [Title 22, CCR, 66262.34(a)l TheJacili(p shall immediately arrange .fbr the removal ql the waste, and shall supply a cujpv ofthe manilest or bill
or lading demonsiratin , removal within days.
GA02
The facility held satellite accumulation wastes for greater than one vear. jTiilc 22, CCR, 66262.34(c)(1)(B)l See GA01 above for corrections.
GA03
The facility failed to properly handle contaminated containers within I vear. ITitle 22, CCR, 66261.7(1 )1 See 0401 above for corrections.
GA04
The facility held universal wastes for greater than one vear. ITille 22, CCR, 66273.15(a) of 66273..35(x) I See G2101 above for corrections.
GA05
The facility held drained used oil filters for greater than 130 days /one vear. ITitle 22, CCR, 66266.130(c)(4) .See G1101 above for corrections.
GA06
The lacilily held lead acid batteries for greater than 130 days /one vear. Title 22, CCR, 66268.8 l(a)(6)1 See G1101 above for corrections.
GL,01
The facility failed to properly label all containers. Containers, contents and missing inlormalion are noted on the front of this page. ITitle 22, CCR,
66262.34(111 TheJiacility shall clearly mark all containers )with tine following: 1) the words "hlazardous waste ". 2) c•onnpos•ilion crud plrnsical state, 3) hazard
ro perm. 4) name and address ofthe ,generator. and 5) accumulation start date.
GI-02
The facility tailed to mark the date the comainer was moved from the satellite accumulation area [Title 22, CCR, 66262.34(c)(I )(B)l Thefcac•i/i(v shall nark
till satellite accumulation with the duce waste is first added cis well as• the elate the container is Ball.
Col-03
The facility failed to mark tanks /container(s) of excluded recyclable materials properly [DISC 25143.9(a)1 The tankslcontainer•s• ol'inaterials shall be clearly
larked with the words "Esclali'd recyclable material" instead of " hazardous t'as'te ".
GI-04
The facility failed to mark a container of universal waste properly. [Tillc 22, CCR, 66273.14 for SQI-I or 66273.34 Ibr LQH 1. Thefarc•ility shall imntedlately
mark all containers holding universal waste with the words "Universal Waste- "
GI-05
The facility failed to mark a container of (trained used oil filters with the words "drained used oil lilters ". [Title 22, CCR, 66266.130(c)(3)l Thefircility shall
mark all filter containers with the words "drained used oil filters ".
GI-06
The facility failed to mark the date on which the battery was received. ITitle 22, CCR, 66266.8 1 (a)(6)(D)l The laacility shall v marl.' the date on each baterv.
GL07
The facility failed to nark a tank /container of used oil destined for recycling with the words "used oil" I HSC 25143.9(a),l Clearly mark all tanks caul
containers with the wads "used oil ".
GI-03
The facility failed to mark the tank of with the 1'title 22, CCR, 66234(11,1 The facility shall
clearly mark the lank with
GL09
The facility failed to mark contaminated containers with the date ell plied. ITitle 22, CCR, 66261.7(8 C /each- nuukal! cauuiners n•ith the date ent pried.
GI101
The facility tailed to remove from an appliance prior to crushing, baling, shredding, sawing or disposing ofthe appliance [DISC
25212(a) l. The lac•i /ity must submit to D7SC an application to be certifier/ as a "Certified Appliance Reevcler"
GT01
The facility failed to obtain a permit ov other authorization for treatment of hazardous waste. IiSC 25189.5(cl)
G 102
The facility failed It) Use a reklCtered trans porterbise'd a transporter or Consolidated waste when they were not eligible -I -ISC 25165(a)/25160
GD01
the facility disposed of hazarcloU5 waste at all UllaUlh01'IZed point. HSC 25139.5(x)
' l):' i ll .. :''I I