Loading...
HomeMy WebLinkAboutFMC Results 2015 (North)MONITORING SYSTEM CERTIFICATION For Use By All Jurisdictions Within the State of CaliforniaAuthority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. A.General Information Facility Name:Bldg. No.: Site Address:City:Zip: Facility Contact Person: Contact Phone No.: Make/Model of Monitoring System:Date of Testing/Servicing: B.Inventory of Equipment Tested/Certified Check the appropriate boxes to indicate specific equipment inspected/serviced: Tank ID:Tank ID: In-Tank Gauging Probe.Model:In-Tank Gauging Probe.Model: Annular Space or Vault Sensor.Model:Annular Space or Vault Sensor.Model: Piping Sump / Trench Sensor(s).Model:Piping Sump / Trench Sensor(s).Model: Fill Sump Sensor(s).Model:Fill Sump Sensor(s).Model: Mechanical Line Leak Detector.Model:Mechanical Line Leak Detector.Model: Electronic Line Leak Detector.Model:Electronic LineLeak Detector.Model: Tank Overfill / High-Level Sensor.Model:Tank Overfill / High-Level Sensor.Model: Other (specify equipment type and model in Section E on Page 2).Other (specify equipment type and model in Section E on Page 2). Tank ID:Tank ID: In-Tank Gauging Probe.Model:In-Tank Gauging Probe.Model: Annular Space or Vault Sensor.Model:Annular Space or Vault Sensor.Model: Piping Sump / TrenchSensor(s).Model:Piping Sump / Trench Sensor(s).Model: Fill Sump Sensor(s).Model:Fill Sump Sensor(s).Model: Mechanical Line Leak Detector.Model:Mechanical Line Leak Detector.Model: Electronic Line Leak Detector.Model:Electronic Line Leak Detector.Model: Tank Overfill / High-Level Sensor.Model:Tank Overfill / High-Level Sensor.Model: Other (specify equipment type and model in Section E on Page 2).Other (specify equipment type and model in Section E on Page 2). Dispenser ID:Dispenser ID: Dispenser Containment Sensor(s).Model:Dispenser Containment Sensor(s).Model: Shear Valve(s).Shear Valve(s). Dispenser Containment Float(s) and Chain(s).Dispenser Containment Float(s) and Chain(s). Dispenser ID:Dispenser ID: Dispenser Containment Sensor(s).Model:Dispenser Containment Sensor(s).Model: Shear Valve(s).Shear Valve(s). Dispenser Containment Float(s) and Chain(s).Dispenser Containment Float(s) and Chain(s). Dispenser ID:Dispenser ID: Dispenser Containment Sensor(s).Model:Dispenser Containment Sensor(s).Model: Shear Valve(s).Shear Valve(s). Dispenser Containment Float(s) and Chain(s).Dispenser Containment Float(s) and Chain(s). *If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. C.Certification -I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers’ guidelines. Attached to this Certification is information (e.g. manufacturers' checklists)necessary to verify that this information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a copy of the report;(check all that apply):System set-up Alarm history report Technician Name (print):Signature: Certification No.:License. No.:804904 Testing Company Name:Confidence UST Services, Inc.Phone No.:(800)339-9930 Site Address:Date of Testing/Servicing: Page 1 of 3 Sully'sDowntown(North) 2317LStreetBakersfield93301 FrankSullivan (661)327-5008 Veeder-RootTLS-350 11/10/2015 12,000gal.Regular 847390-107 794390-420 794390-420 794380-208 794380-208 FX1V 847390-107 8,000gal.Plus 847390-107 FX1V 847390-107 8,000gal.Super 847390-107 794390-420 ■794390-420 794380-208 794380-208 847390-107 12,000gal.Diesel 847390-107 FX1V FX1DV 794380-208 847390-107 13-14 794380-208 794380-208 794380-208 15-16 17-18 19-20 DustinReese B43426 2317LStreet Bakersfield,CA93301 11/10/2015 Monitoring System Certification D.Results of Testing/Servicing Software Version Installed: Complete the following checklist: Yes No*Isthe audible alarm operational? Yes No*Is the visual alarm operational? Yes No*Were all sensors visually inspected, functionally tested, and confirmed operational? Yes No*Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere with their proper operation? Yes No* N/A If alarms are relayed to a remote monitoring station, is all communications equipment (e.g., modem) operational? Yes No* N/A For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate positive shut-down? (Check all that apply) Sump/Trench Sensors; Dispenser Containment Sensors. Did you confirm positive shut-down due to leaks and sensor failure/disconnection? Yes; No. Yes No* N/A For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e., no mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank fill point(s) and operating properly? If so, at what percent oftank capacity does the alarm trigger? % Yes*NoWas any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced and list the manufacturer name and model for all replacement parts in Section E, below. Yes*NoWas liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) Product; Water. If yes, describe causes in Section E, below. Yes No*Was monitoring system set-up reviewed to ensure proper settings? Attach set up reports, if applicable Yes No*Is all monitoring equipment operational per manufacturer’s specifications? * In Section E below, describe how and when these deficiencies were or will be corrected. E.Comments: Page 2 of 3 329.00 90 Changed out a 208 liquid sensor for the 87 STP Sump then I changed the 91 fill Dust Cap. Monitoring System Certification F.In-Tank Gauging / SIR Equipment: Check this box if tank gauging is used only for inventory control. Check this box if no tank gauging or SIR equipment is installed. This section must be completed if in-tank gauging equipment is used to perform leak detection monitoring. Complete the following checklist: Yes No*Has all input wiring been inspected for proper entry and termination, including testing for ground faults? Yes No*Were all tank gauging probes visually inspected for damage and residue buildup? Yes No*Was accuracy of system product level readings tested? Yes No*Was accuracy of system water level readings tested? Yes No*Were all probes reinstalled properly? Yes No*Were all items on the equipment manufacturer’s maintenance checklist completed? * In the Section H, below, describe how and when these deficiencies were or will be corrected. G.Line Leak Detectors (LLD):Check this box if LLDs are not installed. Complete the following checklist: Yes No* N/A For equipment start-up or annual equipment certification, was a leak simulated to verify LLD performance? (Check all that apply)Simulated leak rate: 3 g.p.h.; 0.1 g.p.h ; 0.2 g.p.h. Yes No*Were all LLDs confirmed operational and accurate within regulatory requirements? Yes No*Was the testing apparatus properly calibrated? Yes No* N/A For mechanical LLDs, does the LLD restrict product flow if it detects a leak? Yes No* N/A For electronic LLDs, does the turbine automatically shut off if the LLD detects a leak? Yes No* N/A For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? Yes No* N/A For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a test? Yes No* N/A For electronic LLDs, have all accessible wiring connections been visually inspected? Yes No*Were all items on the equipment manufacturer’s maintenance checklist completed? * In the Section H, below, describe how and when these deficiencies were or will be corrected. H.Comments: Page 3 of 3 Leak Detector Test Results Sheet Customer Address: Work Order: Site Address: Test Date: Site Contact: Phone: Technician: Phone: 800-339-9930 ICC No.: Product Type LLD Type Model Serial No. Check Valve Holding Pressure Bleed Off ML. Leak Rate Tested: Pass/Fail 3 gph @ 10 psi 3 gph @ 10 psi 3 gph @ 10 psi 3 gph @ 10 psi 3 gph @ 10 psi 3 gph @ 10 psi 3 gph @ 10 psi 3 gph @ 10 psi Technician Name: Technician No.: Signature: Date: SullivanPetroleum,LLC 1000TruxtunAvenue Bakersfield,CA93301 35410 11/10/2015 8216722-UT Regular Mechanical FX1V DustinReese (661)327-5008FrankSullivan Bakersfield,CA93301 2317LStreet Sully'sDowntown(North) 16psi125ml Pass FX1VMechanicalPlus 17psi140ml Pass FX1VMechanicalPremium 19psi133ml Pass FX1DVMechanicalDiesel 14psi120ml Pass DustinReese 8216722-UT 11/10/2015 Downtown chevron north System setup Responses Received: 200 189413 DOWNTOWN CHEV 2317 L ST. BAKERSFIELD,CA NOV 10, 2015 11:42 AM TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 1 PLUS 3533 54.34 0.0 77.9 4496 2 UNLEADED 8995 83.91 0.0 76.3 3049 3 SUPREME 4318 63.57 0.0 78.6 3711 4 DIESEL 3604 40.75 0.0 80.4 8440 I90500 NOV 10, 2015 11:42 AM SOFTWARE REVISION LEVEL VERSION 329.00 SOFTWARE# 346329-100-A CREATED - 08.10.09.17.08 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD I50500 NOV 10, 2015 11:42 AM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM I50201 NOV 10, 2015 11:42 AM SHIFT TIME 1 : 6:00 AM I50202 NOV 10, 2015 11:42 AM SHIFT TIME 2 : DISABLED I50203 NOV 10, 2015 11:42 AM SHIFT TIME 3 : DISABLED I50204 NOV 10, 2015 11:42 AM SHIFT TIME 4 : DISABLED I54600 NOV 10, 2015 11:42 AM TANK PER TST NEEDED WRN: DISABLED I54900 NOV 10, 2015 11:42 AM TANK ANN TST NEEDED WRN: DISABLED I55300 NOV 10, 2015 11:42 AM LINE RE-ENABLE METHOD PASS LINE TEST I55600 NOV 10, 2015 11:42 AM LINE PER TST NEEDED WRN: DISABLED I55900 NOV 10, 2015 11:42 AM LINE ANN TST NEEDED WRN: DISABLED I50D00 NOV 10, 2015 11:42 AM PRINT TC VOLUMES ENABLED I50E00 NOV 10, 2015 11:42 AM TEMP COMPENSATION VALUE (DEG F ): 60.0 I60B00 NOV 10, 2015 11:42 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I51400 NOV 10, 2015 11:42 AM H-PROTOCOL DATA FORMAT HEIGHT I51A01 NOV 10, 2015 11:42 AM DAYLIGHT SAVING TIME ENABLED OFF I51B00 NOV 10, 2015 11:42 AM DAYLIGHT SAVING TIME START DATE MAR WEEK 2 SUN 2:00 AM END DATE NOV WEEK 1 SUN 2:00 AM I51600 NOV 10, 2015 11:42 AM RE-DIRECT LOCAL PRINTOUT DISABLED I50400 NOV 10, 2015 11:42 AM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 231782 ENABLED 2 231782 ENABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED I21900 NOV 10, 2015 11:42 AM TANK CHART SECURITY DISABLED I5BD00 NOV 10, 2015 11:42 AM CUSTOM ALARM LABELS DISABLED I56000 NOV 10, 2015 11:42 AM MASS/DENSITY DISABLED I88101 NOV 10, 2015 11:42 AM PORT SETTINGS: COMM BOARD : 1 (EDIM ) RS-232 SECURITY CODE : 231782 I88102 NOV 10, 2015 11:42 AM PORT SETTINGS: COMM BOARD : 2 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : 231782 I88103 NOV 10, 2015 11:42 AM I88104 NOV 10, 2015 11:42 AM I88105 NOV 10, 2015 11:42 AM PORT SETTINGS: COMM BOARD : 5 (S-SAT ) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED DTR NORMAL STATE: HIGH I88106 NOV 10, 2015 11:42 AM I52000 NOV 10, 2015 11:42 AM RECEIVER AUTO DIAL TYPE & START TIME RCVR LOCATION LABEL DIAL TYPE START TIME 1 ON DATE APR 24, 2013 DISABLED 2 ON DATE APR 24, 2013 DISABLED 3 ON DATE APR 24, 2013 DISABLED 4 ON DATE APR 24, 2013 DISABLED 5 ON DATE APR 24, 2013 DISABLED 6 ON DATE APR 24, 2013 DISABLED 7 ON DATE APR 24, 2013 DISABLED 8 VEEDER ROOT (FMS) WEEKLY WED 5:02 PM I60100 NOV 10, 2015 11:42 AM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 PLUS ON 2 UNLEADED ON 3 SUPREME ON 4 DIESEL ON I60200 NOV 10, 2015 11:42 AM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 PLUS 2 UNLEADED 3 SUPREME 4 DIESEL I60300 NOV 10, 2015 11:42 AM TANK PRODUCT CODE TANK PRODUCT LABEL 1 PLUS 1 2 UNLEADED 2 3 SUPREME 3 4 DIESEL 4 I60900 NOV 10, 2015 11:42 AM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 PLUS 0.000700 2 UNLEADED 0.000700 3 SUPREME 0.000700 4 DIESEL 0.000450 I60700 NOV 10, 2015 11:42 AM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 PLUS 120.00 2 UNLEADED 120.00 3 SUPREME 120.00 4 DIESEL 120.00 I60A00 NOV 10, 2015 11:42 AM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 PLUS 1 PT 8029 2 UNLEADED 1 PT 12044 3 SUPREME 1 PT 8029 4 DIESEL 1 PT 12044 I60400 NOV 10, 2015 11:42 AM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 PLUS 8029 2 UNLEADED 12044 3 SUPREME 8029 4 DIESEL 12044 I60500 NOV 10, 2015 11:42 AM TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 PLUS 8029 0 0 0 2 UNLEADED 12044 0 0 0 3 SUPREME 8029 0 0 0 4 DIESEL 12044 0 0 0 I60600 NOV 10, 2015 11:42 AM TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 PLUS 8029 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 UNLEADED 12044 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 SUPREME 8029 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4 DIESEL 12044 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I61500 NOV 10, 2015 11:42 AM TANK PRODUCT LABEL METER DATA 1 PLUS NO 2 UNLEADED NO 3 SUPREME NO 4 DIESEL NO I62F00 NOV 10, 2015 11:42 AM MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: 1 PLUS 4.0 INCHES 2 UNLEADED 4.0 INCHES 3 SUPREME 4.0 INCHES 4 DIESEL 4.0 INCHES I62700 NOV 10, 2015 11:42 AM TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES 1 PLUS 2.0 2 UNLEADED 2.0 3 SUPREME 2.0 4 DIESEL 2.0 9999FF1B I62400 NOV 10, 2015 11:42 AM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 PLUS 3.0 2 UNLEADED 3.0 3 SUPREME 3.0 4 DIESEL 3.0 I62800 NOV 10, 2015 11:42 AM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 PLUS 8029 2 UNLEADED 12044 3 SUPREME 8029 4 DIESEL 12044 I62300 NOV 10, 2015 11:42 AM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 PLUS 7226 2 UNLEADED 10839 3 SUPREME 7226 4 DIESEL 10839 I62200 NOV 10, 2015 11:42 AM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 PLUS 7627 2 UNLEADED 11441 3 SUPREME 7627 4 DIESEL 11441 I62900 NOV 10, 2015 11:42 AM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 PLUS 802 2 UNLEADED 1204 3 SUPREME 802 4 DIESEL 1204 I62100 NOV 10, 2015 11:42 AM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 PLUS 500 2 UNLEADED 500 3 SUPREME 500 4 DIESEL 1200 I62600 NOV 10, 2015 11:42 AM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 PLUS 99 2 UNLEADED 99 3 SUPREME 99 4 DIESEL 99 I62500 NOV 10, 2015 11:42 AM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 PLUS 50 2 UNLEADED 50 3 SUPREME 99 4 DIESEL 99 I60800 NOV 10, 2015 11:42 AM TANK TILT TANK PRODUCT LABEL INCHES 1 PLUS 0.60 2 UNLEADED 0.00 3 SUPREME 0.96 4 DIESEL 1.60 I60B00 NOV 10, 2015 11:42 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I60C00 NOV 10, 2015 11:42 AM TANK STICK HEIGHT OFFSET TANK PRODUCT LABEL INCHES 1 PLUS 0.00 2 UNLEADED 0.00 3 SUPREME 0.00 4 DIESEL 0.00 I61200 NOV 10, 2015 11:42 AM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 PLUS NONE NONE 2 UNLEADED NONE NONE 3 SUPREME NONE NONE 4 DIESEL NONE NONE I63600 NOV 10, 2015 11:42 AM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 PLUS 802 2 UNLEADED 1204 3 SUPREME 802 4 DIESEL 1204 I62A00 NOV 10, 2015 11:42 AM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 PLUS 802 2 UNLEADED 1204 3 SUPREME 802 4 DIESEL 1204 I62C00 NOV 10, 2015 11:42 AM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 PLUS QUICK 2 UNLEADED QUICK 3 SUPREME STANDARD 4 DIESEL STANDARD I62D00 NOV 10, 2015 11:42 AM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 PLUS GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 2 UNLEADED GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 3 SUPREME GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 4 DIESEL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED I63100 NOV 10, 2015 11:42 AM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 PLUS OFF OFF 2 UNLEADED OFF OFF 3 SUPREME OFF OFF 4 DIESEL OFF OFF I63000 NOV 10, 2015 11:42 AM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 PLUS OFF 2 UNLEADED OFF 3 SUPREME OFF 4 DIESEL OFF I63200 NOV 10, 2015 11:42 AM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 PLUS OFF 2 UNLEADED OFF 3 SUPREME OFF 4 DIESEL OFF I61000 NOV 10, 2015 11:42 AM TANK DELIVERY DELAY TANK PRODUCT LABEL 1 PLUS 1 2 UNLEADED 1 3 SUPREME 1 4 DIESEL 1 I63A00 NOV 10, 2015 11:42 AM LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD TANK PRODUCT LABEL PUMP THRESHOLD 1 PLUS 10.00% 2 UNLEADED 10.00% 3 SUPREME 10.00% 4 DIESEL 10.00% I61100 NOV 10, 2015 11:42 AM LEAK TEST METHOD - - - - - - - - - - - - TEST ON DATE : ALL TANK OCT 9, 2008 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED I61300 NOV 10, 2015 11:42 AM CSLD PROBABLITY OF DETECTION I61400 NOV 10, 2015 11:42 AM CSLD CLIMATE FACTOR I61600 NOV 10, 2015 11:42 AM TANK PRODUCT LABEL CAL UPDATE 1 PLUS IMMEDIATE 2 UNLEADED IMMEDIATE 3 SUPREME IMMEDIATE 4 DIESEL IMMEDIATE I61A00 NOV 10, 2015 11:42 AM IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 PLUS DISABLED 2 UNLEADED DISABLED 3 SUPREME DISABLED 4 DIESEL DISABLED I61B00 NOV 10, 2015 11:42 AM IN-TANK LEAK GROSS TEST AUTO-CONFIRM I61C00 NOV 10, 2015 11:42 AM CSLD REPORT ONLY I62B00 NOV 10, 2015 11:42 AM TANK LAST ANNUAL TEST TANK PRODUCT LABEL DATE 1 PLUS ??? 0, 0 2 UNLEADED ??? 0, 0 3 SUPREME ??? 0, 0 4 DIESEL ??? 0, 0 I63300 NOV 10, 2015 11:42 AM LEAK TEST REPORT FORMAT: NORMAL I63400 NOV 10, 2015 11:42 AM RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 PLUS 0 2 UNLEADED 0 3 SUPREME 0 4 DIESEL 0 I63500 NOV 10, 2015 11:42 AM RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 PLUS 1 2 UNLEADED 1 3 SUPREME 1 4 DIESEL 1 I63900 NOV 10, 2015 11:42 AM ACCU CHART END SHAPE FACTOR TANK PRODUCT LABEL 1 PLUS END FACTOR: NONE 2 UNLEADED END FACTOR: NONE 3 SUPREME END FACTOR: NONE 4 DIESEL END FACTOR: NONE I78000 NOV 10, 2015 11:42 AM I77700 NOV 10, 2015 11:43 AM I77800 NOV 10, 2015 11:43 AM I78C00 NOV 10, 2015 11:43 AM I78300 NOV 10, 2015 11:43 AM I78F00 NOV 10, 2015 11:43 AM I78700 NOV 10, 2015 11:43 AM I70200 NOV 10, 2015 11:43 AM LIQUID LABEL DEVICE LABEL 1 89 STP 2 89-87 ANN 3 87 STP 4 91 STP 5 DSL STP 6 91 DSL ANN 7 PAN 15-16 8 PAN 17-18 9 PAN 19-20 10 PAN 13-14 11 12 13 14 15 16 I70300 NOV 10, 2015 11:43 AM LIQUID TYPE SENSOR LOCATION TYPE 1 89 STP TRI-STATE (SINGLE FLOAT) 2 89-87 ANN TRI-STATE (SINGLE FLOAT) 3 87 STP TRI-STATE (SINGLE FLOAT) 4 91 STP TRI-STATE (SINGLE FLOAT) 5 DSL STP TRI-STATE (SINGLE FLOAT) 6 91 DSL ANN TRI-STATE (SINGLE FLOAT) 7 PAN 15-16 TRI-STATE (SINGLE FLOAT) 8 PAN 17-18 TRI-STATE (SINGLE FLOAT) 9 PAN 19-20 TRI-STATE (SINGLE FLOAT) 10 PAN 13-14 TRI-STATE (SINGLE FLOAT) 11 TRI-STATE (SINGLE FLOAT) 12 TRI-STATE (SINGLE FLOAT) 13 TRI-STATE (SINGLE FLOAT) 14 TRI-STATE (SINGLE FLOAT) 15 TRI-STATE (SINGLE FLOAT) 16 TRI-STATE (SINGLE FLOAT) I70400 NOV 10, 2015 11:43 AM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 89 STP STP SUMP 2 89-87 ANN ANNULAR SPACE 3 87 STP STP SUMP 4 91 STP STP SUMP 5 DSL STP STP SUMP 6 91 DSL ANN ANNULAR SPACE 7 PAN 15-16 DISPENSER PAN 8 PAN 17-18 DISPENSER PAN 9 PAN 19-20 DISPENSER PAN 10 PAN 13-14 DISPENSER PAN 11 OTHER SENSORS 12 OTHER SENSORS 13 OTHER SENSORS 14 OTHER SENSORS 15 OTHER SENSORS 16 OTHER SENSORS I74200 NOV 10, 2015 11:43 AM I74300 NOV 10, 2015 11:43 AM I74400 NOV 10, 2015 11:43 AM I74700 NOV 10, 2015 11:43 AM I74800 NOV 10, 2015 11:43 AM I74900 NOV 10, 2015 11:43 AM I7BC00 NOV 10, 2015 11:43 AM I80200 NOV 10, 2015 11:43 AM I80300 NOV 10, 2015 11:43 AM I80400 NOV 10, 2015 11:43 AM I80700 NOV 10, 2015 11:43 AM RELAY LABEL DEVICE LABEL 1 UNLEADED 2 PLUS 3 SUPREME 4 DIESEL 5 OVERFILL ALARM 6 7 8 I80900 NOV 10, 2015 11:43 AM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 UNLEADED NORMALLY CLOSED 2 PLUS NORMALLY CLOSED 3 SUPREME NORMALLY CLOSED 4 DIESEL NORMALLY CLOSED 5 OVERFILL ALARM NORMALLY OPEN 6 NORMALLY OPEN 7 NORMALLY OPEN 8 NORMALLY OPEN I80B00 NOV 10, 2015 11:43 AM RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 UNLEADED 2 2 PLUS 1 3 SUPREME 3 4 DIESEL 4 5 OVERFILL ALARM NONE 6 1 7 1 8 1 I80A00 NOV 10, 2015 11:43 AM RELAY TYPE RELAY DESIGNATION TYPE 1 UNLEADED STANDARD 2 PLUS STANDARD 3 SUPREME STANDARD 4 DIESEL STANDARD 5 OVERFILL ALARM STANDARD 6 STANDARD 7 STANDARD 8 STANDARD I80C00 NOV 10, 2015 11:43 AM I80800 NOV 10, 2015 11:43 AM RELAY SETUP REPORT R 1:UNLEADED TYPE: STANDARD NORMALLY CLOSED TANK #: 2 LIQUID SENSOR ALMS L 2:FUEL ALARM L 3:FUEL ALARM L 7:FUEL ALARM L 8:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L 2:SENSOR OUT ALARM L 3:SENSOR OUT ALARM L 7:SENSOR OUT ALARM L 8:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L 2:SHORT ALARM L 3:SHORT ALARM L 7:SHORT ALARM L 8:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS h 1:GROSS COLLECT FAIL h 2:GROSS COLLECT FAIL h 3:GROSS COLLECT FAIL h 4:GROSS COLLECT FAIL h 5:GROSS COLLECT FAIL h 6:GROSS COLLECT FAIL h 7:GROSS COLLECT FAIL h 8:GROSS COLLECT FAIL h 1:DEGRD COLLECT FAIL h 2:DEGRD COLLECT FAIL h 3:DEGRD COLLECT FAIL h 4:DEGRD COLLECT FAIL h 5:DEGRD COLLECT FAIL h 6:DEGRD COLLECT FAIL h 7:DEGRD COLLECT FAIL h 8:DEGRD COLLECT FAIL R 2:PLUS TYPE: STANDARD NORMALLY CLOSED TANK #: 1 IN-TANK ALARMS ALL:OVERFILL ALARM ALL:HIGH PRODUCT ALARM ALL:MAX PRODUCT ALARM LIQUID SENSOR ALMS L 1:FUEL ALARM L 2:FUEL ALARM L 7:FUEL ALARM L 8:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L 1:SENSOR OUT ALARM L 2:SENSOR OUT ALARM L 7:SENSOR OUT ALARM L 8:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L 1:SHORT ALARM L 2:SHORT ALARM L 7:SHORT ALARM L 8:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS h 1:GROSS COLLECT FAIL h 2:GROSS COLLECT FAIL h 3:GROSS COLLECT FAIL h 4:GROSS COLLECT FAIL h 5:GROSS COLLECT FAIL h 6:GROSS COLLECT FAIL h 7:GROSS COLLECT FAIL h 8:GROSS COLLECT FAIL h 1:DEGRD COLLECT FAIL h 2:DEGRD COLLECT FAIL h 3:DEGRD COLLECT FAIL h 4:DEGRD COLLECT FAIL h 5:DEGRD COLLECT FAIL h 6:DEGRD COLLECT FAIL h 7:DEGRD COLLECT FAIL h 8:DEGRD COLLECT FAIL R 3:SUPREME TYPE: STANDARD NORMALLY CLOSED TANK #: 3 LIQUID SENSOR ALMS L 4:FUEL ALARM L 6:FUEL ALARM L 7:FUEL ALARM L 8:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L 4:SENSOR OUT ALARM L 6:SENSOR OUT ALARM L 7:SENSOR OUT ALARM L 8:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L 4:SHORT ALARM L 6:SHORT ALARM L 7:SHORT ALARM L 8:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS h 1:GROSS COLLECT FAIL h 2:GROSS COLLECT FAIL h 3:GROSS COLLECT FAIL h 4:GROSS COLLECT FAIL h 5:GROSS COLLECT FAIL h 6:GROSS COLLECT FAIL h 7:GROSS COLLECT FAIL h 8:GROSS COLLECT FAIL h 1:DEGRD COLLECT FAIL h 2:DEGRD COLLECT FAIL h 3:DEGRD COLLECT FAIL h 4:DEGRD COLLECT FAIL h 5:DEGRD COLLECT FAIL h 6:DEGRD COLLECT FAIL h 7:DEGRD COLLECT FAIL h 8:DEGRD COLLECT FAIL R 4:DIESEL TYPE: STANDARD NORMALLY CLOSED TANK #: 4 LIQUID SENSOR ALMS L 5:FUEL ALARM L 6:FUEL ALARM L 7:FUEL ALARM L 8:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L 5:SENSOR OUT ALARM L 6:SENSOR OUT ALARM L 7:SENSOR OUT ALARM L 8:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L 5:SHORT ALARM L 6:SHORT ALARM L 7:SHORT ALARM L 8:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM R 5:OVERFILL ALARM TYPE: STANDARD NORMALLY OPEN TANK #: NONE IN-TANK ALARMS ALL:OVERFILL ALARM ALL:HIGH PRODUCT ALARM ALL:MAX PRODUCT ALARM R 6: TYPE: STANDARD NORMALLY OPEN TANK #: 1 - NO ALARM ASSIGNMENTS - R 7: TYPE: STANDARD NORMALLY OPEN TANK #: 1 - NO ALARM ASSIGNMENTS - R 8: TYPE: STANDARD NORMALLY OPEN TANK #: 1 - NO ALARM ASSIGNMENTS - I79000 NOV 10, 2015 11:43 AM EDIM:1 VR:349634-003-C TD:06.05.11.11.15 I79100 NOV 10, 2015 11:44 AM I72300 NOV 10, 2015 11:44 AM 189413 DOWNTOWN CHEV 2317 L ST. BAKERSFIELD,CA SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY 01 FM 13-14 AIR FLOW METER 02 FM 15-16 AIR FLOW METER 03 FM 17-18 AIR FLOW METER 04 FM 19-20 AIR FLOW METER 05 UNKNOWN 06 UNKNOWN 07 UNKNOWN 08 PS 19-20 VAPOR PRESSURE 09 UNKNOWN 10 UNKNOWN 11 UNKNOWN 12 UNKNOWN 13 UNKNOWN 14 UNKNOWN 15 UNKNOWN 16 UNKNOWN 17 UNKNOWN 18 UNKNOWN 19 UNKNOWN 20 UNKNOWN 21 UNKNOWN 22 UNKNOWN 23 UNKNOWN 24 UNKNOWN 25 UNKNOWN 26 UNKNOWN 27 UNKNOWN 28 UNKNOWN 29 UNKNOWN 30 UNKNOWN 31 UNKNOWN 32 UNKNOWN 33 UNKNOWN 34 UNKNOWN 35 UNKNOWN 36 UNKNOWN 37 UNKNOWN 38 UNKNOWN 39 UNKNOWN 40 UNKNOWN I72A00 NOV 10, 2015 11:44 AM VACUUM SENSOR VOLUME DEVICE LABEL VOLUME IV4E00 NOV 10, 2015 11:44 AM 189413 DOWNTOWN CHEV 2317 L ST. BAKERSFIELD,CA EVR/ISD SETUP TYPE: VACUUM ASSIST VACUUM ASSIST TYPE: HEALY VAC IV4F00 NOV 10, 2015 11:44 AM 189413 DOWNTOWN CHEV 2317 L ST. BAKERSFIELD,CA NOZZLE A/L RANGE A/L RATIO: 0.95 - 1.15 IV4000 NOV 10, 2015 11:44 AM 189413 DOWNTOWN CHEV 2317 L ST. BAKERSFIELD,CA VAPOR PROCESSOR TYPE NONE IV4700 NOV 10, 2015 11:44 AM 189413 DOWNTOWN CHEV 2317 L ST. BAKERSFIELD,CA ASSESSMENT TIME START TIME: 10:00 AM TIME DELAY MINUTES: 1 IV5200 NOV 10, 2015 11:44 AM 189413 DOWNTOWN CHEV 2317 L ST. BAKERSFIELD,CA ACCEPT HIGH ORVR: NO IV4A00 NOV 10, 2015 11:44 AM 189413 DOWNTOWN CHEV 2317 L ST. BAKERSFIELD,CA ISD HOSE TABLE HOSE FP FP AFM HOSE ID ID LABEL ID LABEL 01 29 01 01 BLEND3 02 30 02 01 BLEND3 03 31 03 02 BLEND3 04 16 04 02 BLEND3 05 12 05 03 BLEND3 06 13 06 03 BLEND3 07 14 07 04 BLEND3 08 15 08 04 BLEND3 IV4B00 NOV 10, 2015 11:44 AM 189413 DOWNTOWN CHEV 2317 L ST. BAKERSFIELD,CA PRODUCT/HOSE MAP TABLE FP AFID M1/H1 M2/H2 M3/H3 M4/H4 12 03 00/05 01/05 02/05 xx/xx 13 03 00/06 01/06 02/06 xx/xx 14 04 00/07 01/07 02/07 xx/xx 15 04 00/08 01/08 02/08 xx/xx 16 02 00/04 01/04 02/04 xx/xx 29 01 00/01 01/01 02/01 xx/xx 30 01 00/02 01/02 02/02 xx/xx 31 02 00/03 01/03 02/03 xx/xx IV4900 NOV 10, 2015 11:44 AM 189413 DOWNTOWN CHEV 2317 L ST. BAKERSFIELD,CA LABEL TABLE ID LABEL 01 UNASSIGNED 02 BLEND3 03 REGULAR 04 MID GRADE 05 PREMIUM 06 GOLD 07 BRONZE 08 SILVER 09 BLEND2 10 BLEND4 IV1000 NOV 10, 2015 11:44 AM ISD VERSION: 01.02 Downtown chevron north Alarm history before: Responses Received: I10200 NOV 10, 2015 11:47 AM 189413 DOWNTOWN CHEV 2317 L ST. BAKERSFIELD,CA SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 8SMARTSENSOR BD 39382 39446 2 INTERSTITIAL BD 201464 202362 3 INTERSTITIAL BD 200857 201662 4 4 PROBE / G.T. 162400 162884 5 UNUSED 9587041 8759233 6 UNUSED 9578014 15000000 7 UNUSED 9577352 15000000 8 UNUSED 9578936 8541821 9 RELAY BOARD 14900 14932 10 RELAY BOARD 9581002 14992 11 UNUSED 9579818 8197816 12 UNUSED 9578835 9122663 13 UNUSED 9580540 15000000 14 UNUSED 9580781 8590117 15 UNUSED 9581463 15000000 16 UNUSED 9579798 8504381 COMM 1 ELEC DISP INT. 100703 100974 COMM 2 RS232 SERIAL BD 14960 14972 COMM 3 UNUSED 9583810 8488757 COMM 4 UNUSED 9578594 15000000 COMM 5 SERIAL SAT BD 479440 483080 COMM 6 UNUSED 9576749 8553170 I90200 NOV 10, 2015 11:47 AM SOFTWARE REVISION LEVEL VERSION 329.00 SOFTWARE# 346329-100-A CREATED - 08.10.09.17.08 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD I11100 NOV 10, 2015 11:47 AM 189413 DOWNTOWN CHEV 2317 L ST. BAKERSFIELD,CA PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 2 TANK UNLEADED OVERFILL ALARM CLEAR 10-18-15 3:02AM T 2 TANK UNLEADED OVERFILL ALARM ALARM 10-18-15 2:58AM T 2 TANK UNLEADED OVERFILL ALARM CLEAR 10-07-15 9:09PM T 2 TANK UNLEADED OVERFILL ALARM ALARM 10-07-15 9:05PM T 2 TANK UNLEADED PROBE OUT CLEAR 9-14-15 1:33PM T 2 TANK UNLEADED PROBE OUT ALARM 9-14-15 1:30PM h 6 OTHER FP6: BLEND3 DEGRD COLLECT FAIL CLEAR 9-09-15 3:18PM h 6 OTHER FP6: BLEND3 DEGRD COLLECT FAIL ALARM 9-09-15 10:06AM T 2 TANK UNLEADED OVERFILL ALARM CLEAR 9-01-15 2:25AM T 2 TANK UNLEADED OVERFILL ALARM ALARM 9-01-15 2:21AM L 9 DISP PAN PAN 19-20 SENSOR OUT ALARM CLEAR 8-24-15 2:42PM L 9 DISP PAN PAN 19-20 SENSOR OUT ALARM ALARM 8-24-15 2:42PM T 2 TANK UNLEADED OVERFILL ALARM CLEAR 8-20-15 4:40AM T 2 TANK UNLEADED OVERFILL ALARM ALARM 8-20-15 4:37AM T 2 TANK UNLEADED OVERFILL ALARM CLEAR 8-09-15 5:21AM T 2 TANK UNLEADED OVERFILL ALARM ALARM 8-09-15 5:18AM T 2 TANK UNLEADED OVERFILL ALARM CLEAR 7-29-15 9:24PM T 2 TANK UNLEADED OVERFILL ALARM ALARM 7-29-15 9:21PM D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 7-24-15 4:09PM D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 7-20-15 10:29AM D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 7-20-15 10:29AM D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 7-19-15 5:02PM D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 7-19-15 5:02PM D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 7-18-15 4:48PM D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 7-18-15 4:48PM D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 7-16-15 1:07AM D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 7-16-15 1:07AM T 2 TANK UNLEADED OVERFILL ALARM CLEAR 7-16-15 12:47AM T 2 TANK UNLEADED OVERFILL ALARM ALARM 7-16-15 12:42AM D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 7-13-15 4:50PM OTHER MISSING HOSE SETUP CLEAR 7-08-15 3:22PM OTHER MISS VAPOR FLOW MTR CLEAR 7-08-15 2:43PM OTHER MISS VAPOR FLOW MTR ALARM 7-08-15 1:28PM OTHER MISS VAPOR FLOW MTR CLEAR 7-08-15 1:24PM OTHER MISS VAPOR FLOW MTR ALARM 7-08-15 1:20PM OTHER MISSING HOSE SETUP ALARM 7-08-15 1:20PM T 2 TANK UNLEADED OVERFILL ALARM CLEAR 7-07-15 4:06AM T 2 TANK UNLEADED OVERFILL ALARM ALARM 7-07-15 4:01AM L 3 STP SUMP 87 STP FUEL ALARM CLEAR 6-29-15 10:54AM L 1 STP SUMP 89 STP FUEL ALARM CLEAR 6-29-15 10:42AM L 7 DISP PAN PAN 15-16 FUEL ALARM CLEAR 6-29-15 9:43AM L 8 DISP PAN PAN 17-18 FUEL ALARM CLEAR 6-29-15 9:42AM L 9 DISP PAN PAN 19-20 FUEL ALARM CLEAR 6-29-15 9:42AM L 9 DISP PAN PAN 19-20 FUEL ALARM ALARM 6-29-15 9:40AM L 8 DISP PAN PAN 17-18 FUEL ALARM ALARM 6-29-15 9:40AM L 7 DISP PAN PAN 15-16 FUEL ALARM ALARM 6-29-15 9:39AM L 6 ANNULAR 91 DSL ANN FUEL ALARM CLEAR 6-29-15 9:05AM L 6 ANNULAR 91 DSL ANN FUEL ALARM ALARM 6-29-15 9:04AM L 1 STP SUMP 89 STP FUEL ALARM ALARM 6-29-15 9:01AM L 6 ANNULAR 91 DSL ANN SENSOR OUT ALARM CLEAR 6-29-15 9:00AM I11200 NOV 10, 2015 11:47 AM 189413 DOWNTOWN CHEV 2317 L ST. BAKERSFIELD,CA NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME OTHER ISD GROSS PRES WARN ALARM 11-10-15 10:01AM SYSTEM PRINTER ERROR CLEAR 11-10-15 9:15AM SYSTEM PAPER OUT CLEAR 11-10-15 9:15AM SYSTEM PRINTER ERROR ALARM 11-10-15 9:15AM SYSTEM PAPER OUT ALARM 11-10-15 9:15AM h 6 OTHER FP6: BLEND3 DEGRD COLLECT WARN CLEAR 11-09-15 4:20PM h 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN CLEAR 11-09-15 10:00AM h 1 OTHER FP1: BLEND3 DEGRD COLLECT WARN CLEAR 11-09-15 10:00AM h 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN ALARM 11-08-15 10:01AM h 1 OTHER FP1: BLEND3 DEGRD COLLECT WARN ALARM 11-08-15 10:01AM h 1 OTHER FP1: BLEND3 DEGRD COLLECT WARN CLEAR 11-07-15 10:00AM h 6 OTHER FP6: BLEND3 DEGRD COLLECT WARN ALARM 11-06-15 10:03AM h 1 OTHER FP1: BLEND3 DEGRD COLLECT WARN ALARM 11-06-15 10:03AM OTHER ISD GROSS PRES WARN CLEAR 11-03-15 5:34PM SYSTEM PRINTER ERROR CLEAR 11-03-15 10:04AM SYSTEM PAPER OUT CLEAR 11-03-15 10:04AM SYSTEM PAPER OUT ALARM 11-03-15 10:04AM SYSTEM PRINTER ERROR ALARM 11-03-15 10:04AM OTHER ISD GROSS PRES WARN ALARM 11-03-15 10:03AM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN CLEAR 11-02-15 10:00AM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN ALARM 11-01-15 10:04AM h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN CLEAR 10-23-15 12:06PM h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN ALARM 10-22-15 10:05AM h 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN CLEAR 10-20-15 10:00AM h 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN ALARM 10-18-15 10:06AM h 1 OTHER FP1: BLEND3 DEGRD COLLECT WARN CLEAR 10-13-15 10:00AM h 1 OTHER FP1: BLEND3 DEGRD COLLECT WARN ALARM 10-12-15 10:05AM h 1 OTHER FP1: BLEND3 DEGRD COLLECT WARN CLEAR 10-11-15 10:00AM h 1 OTHER FP1: BLEND3 DEGRD COLLECT WARN ALARM 10-10-15 10:04AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN CLEAR 10-06-15 10:00AM SYSTEM PRINTER ERROR CLEAR 10-06-15 3:06AM SYSTEM PRINTER ERROR ALARM 10-06-15 3:06AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN ALARM 10-05-15 10:05AM SYSTEM PRINTER ERROR CLEAR 9-26-15 12:10AM SYSTEM PAPER OUT CLEAR 9-26-15 12:10AM SYSTEM PRINTER ERROR ALARM 9-26-15 12:08AM SYSTEM PAPER OUT ALARM 9-26-15 12:08AM h 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN CLEAR 9-25-15 10:00AM h 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN ALARM 9-24-15 10:05AM h 1 OTHER FP1: BLEND3 DEGRD COLLECT WARN CLEAR 9-20-15 10:00AM h 1 OTHER FP1: BLEND3 DEGRD COLLECT WARN ALARM 9-19-15 10:06AM h 6 OTHER FP6: BLEND3 DEGRD COLLECT WARN CLEAR 9-14-15 2:28PM OTHER ISD GROSS PRES WARN CLEAR 9-14-15 2:28PM T 2 TANK UNLEADED LOW TEMP WARNING CLEAR 9-14-15 1:33PM T 2 TANK UNLEADED LOW TEMP WARNING ALARM 9-14-15 1:33PM h 6 OTHER FP6: BLEND3 DEGRD COLLECT WARN ALARM 9-13-15 10:03AM OTHER ISD GROSS PRES WARN ALARM 9-12-15 10:03AM h 6 OTHER FP6: BLEND3 DEGRD COLLECT WARN CLEAR 9-09-15 10:00AM SYSTEM PRINTER ERROR CLEAR 9-08-15 10:22PM SYSTEM PAPER OUT CLEAR 9-08-15 10:22PM I20600 NOV 10, 2015 11:47 AM 189413 DOWNTOWN CHEV 2317 L ST. BAKERSFIELD,CA TANK ALARM HISTORY TANK 1 PLUS TANK 2 UNLEADED OVERFILL ALARM OCT 18, 2015 2:58 AM OCT 7, 2015 9:05 PM SEP 1, 2015 2:21 AM PROBE OUT SEP 14, 2015 1:30 PM MAY 4, 2015 11:49 AM LOW TEMP WARNING SEP 14, 2015 1:33 PM TANK 3 SUPREME LOW PRODUCT ALARM JUN 8, 2015 10:04 AM INVALID FUEL LEVEL JUN 8, 2015 10:12 AM PROBE OUT JUN 15, 2015 6:59 AM JUN 11, 2015 6:49 AM JUN 10, 2015 7:28 AM DELIVERY NEEDED JUN 8, 2015 9:51 AM TANK 4 DIESEL I38200 NOV 10, 2015 11:47 AM I30200 NOV 10, 2015 11:47 AM 189413 DOWNTOWN CHEV 2317 L ST. BAKERSFIELD,CA LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 89 STP JUN 29, 2015 9:01 AM FUEL ALARM JUN 29, 2015 8:52 AM FUEL ALARM JUN 29, 2015 7:51 AM FUEL ALARM 2 89-87 ANN JUN 29, 2015 8:37 AM FUEL ALARM JUN 10, 2015 9:27 AM FUEL ALARM MAR 12, 2015 10:39 AM SENSOR OUT ALARM 3 87 STP JUN 29, 2015 8:35 AM FUEL ALARM JUN 22, 2015 3:07 PM FUEL ALARM JUN 22, 2015 11:46 AM FUEL ALARM 4 91 STP JUN 29, 2015 8:36 AM FUEL ALARM JUN 25, 2015 9:32 AM FUEL ALARM JUN 19, 2015 8:48 AM FUEL ALARM 5 DSL STP JUN 29, 2015 8:52 AM FUEL ALARM JUN 29, 2015 8:36 AM FUEL ALARM JUN 25, 2015 10:23 AM FUEL ALARM 6 91 DSL ANN JUN 29, 2015 9:04 AM FUEL ALARM JUN 29, 2015 8:56 AM SENSOR OUT ALARM JUN 29, 2015 8:56 AM SENSOR OUT ALARM 7 PAN 15-16 JUN 29, 2015 9:39 AM FUEL ALARM JUN 23, 2015 7:13 AM SENSOR OUT ALARM JUN 20, 2015 11:01 AM SENSOR OUT ALARM 8 PAN 17-18 JUN 29, 2015 9:40 AM FUEL ALARM JUN 22, 2015 8:15 AM SENSOR OUT ALARM JUN 22, 2015 8:10 AM FUEL ALARM 9 PAN 19-20 AUG 24, 2015 2:42 PM SENSOR OUT ALARM JUN 29, 2015 9:40 AM FUEL ALARM JUN 23, 2015 11:49 AM SENSOR OUT ALARM 10 PAN 13-14 JUN 22, 2015 7:49 AM SENSOR OUT ALARM JUN 22, 2015 7:48 AM FUEL ALARM JUN 22, 2015 7:34 AM SENSOR OUT ALARM I31600 NOV 10, 2015 11:47 AM 189413 DOWNTOWN CHEV 2317 L ST. BAKERSFIELD,CA SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 FM 13-14 JUN 3, 2015 10:41 AM COMMUNICATION ALARM 2 FM 15-16 JUN 3, 2015 11:22 AM COMMUNICATION ALARM 3 FM 17-18 JUN 3, 2015 10:36 AM COMMUNICATION ALARM 4 FM 19-20 JUN 3, 2015 10:49 AM COMMUNICATION ALARM 8 PS 19-20 JUN 3, 2015 10:46 AM COMMUNICATION ALARM I40200 NOV 10, 2015 11:47 AM I40300 NOV 10, 2015 11:47 AM I34200 NOV 10, 2015 11:47 AM I34700 NOV 10, 2015 11:47 AM IV0100 NOV 10, 2015 11:47 AM 189413 DOWNTOWN CHEV 2317 L ST. BAKERSFIELD,CA ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.02 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :WARN EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :WARN ISD MONITOR UP-TIME :100% STAGE I TRANSFERS: 0 of 0 NOTEST EVR/ISD PASS TIME : 0% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 15-11-10 10:01:30 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.64 15-11-08 10:01:59 A/L RATIO DEGRADATION FP 6 BLEND3 0.76 15-11-08 10:01:59 A/L RATIO DEGRADATION FP 5 BLEND3 0.80 15-11-08 10:01:59 A/L RATIO DEGRADATION FP 1 BLEND3 0.81 15-11-07 10:03:12 A/L RATIO DEGRADATION FP 6 BLEND3 0.76 15-11-06 10:03:18 A/L RATIO DEGRADATION FP 6 BLEND3 0.80 15-11-06 10:03:18 A/L RATIO DEGRADATION FP 1 BLEND3 0.80 15-11-03 10:03:55 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.40 15-11-01 10:04:17 A/L RATIO DEGRADATION FP 7 BLEND3 0.78 15-10-23 10:04:51 A/L RATIO DEGRADATION FP 3 BLEND3 0.79 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 15-09-09 10:06:19 A/L RATIO DEGRADATION FP 6 BLEND3 0.76 15-06-23 10:01:09 SENSOR OUT SELFTEST s 8 15-06-23 10:01:09 SENSOR OUT SELFTEST s 4 15-06-23 10:01:09 SETUP SELFTEST MISSING SHUTDOWN RELAY(S) 15-06-22 10:01:09 SENSOR OUT SELFTEST s 8 15-06-22 10:01:09 SENSOR OUT SELFTEST s 4 15-06-22 10:01:09 SENSOR OUT SELFTEST s 3 15-06-22 10:01:09 SENSOR OUT SELFTEST s 2 15-06-22 10:01:09 SENSOR OUT SELFTEST s 1 15-06-22 10:01:09 SETUP SELFTEST MISSING SHUTDOWN RELAY(S) SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 15-11-09 16:20:24 COLLECTION TEST HH06 GRADE TEST MANUALLY CLEARED 15-11-03 17:34:34 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 15-11-01 01:00:00 TIME CHANGE DETECTED AT: 15-11-01 02:00:13 15-10-23 12:06:41 COLLECTION TEST HH03 GRADE TEST MANUALLY CLEARED 15-09-14 14:28:45 COLLECTION TEST HH06 GRADE TEST MANUALLY CLEARED 15-09-14 14:28:37 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 15-09-09 15:18:55 COLLECTION TEST HH06 GRADE TEST MANUALLY CLEARED 15-09-09 10:48:05 PUMPS MANUALLY RE-ENABLED 15-09-09 10:06:19 A/L RATIO GROSS DEGRADATION DISABLED FP 06 BLEND3 15-07-25 10:04:48 READINESS ISD:PP EVR:PP ISD & EVR READY Downtown Chev North Alarm Hist After: Responses Received: I10200 NOV 10, 2015 3:27 PM 189413 DOWNTOWN CHEV 2317 L ST. BAKERSFIELD,CA SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 8SMARTSENSOR BD 39382 39456 2 INTERSTITIAL BD 201464 202867 3 INTERSTITIAL BD 200857 201330 4 4 PROBE / G.T. 162400 163169 5 UNUSED 9587041 15000000 6 UNUSED 9578014 8905919 7 UNUSED 9577352 15000000 8 UNUSED 9578936 9115882 9 RELAY BOARD 14900 14892 10 RELAY BOARD 9581002 14972 11 UNUSED 9579818 8239482 12 UNUSED 9578835 7992948 13 UNUSED 9580540 9530808 14 UNUSED 9580781 15000000 15 UNUSED 9581463 8258127 16 UNUSED 9579798 8260208 COMM 1 ELEC DISP INT. 100703 100922 COMM 2 RS232 SERIAL BD 14960 14972 COMM 3 UNUSED 9583810 8215454 COMM 4 UNUSED 9578594 8391147 COMM 5 SERIAL SAT BD 479440 485169 COMM 6 UNUSED 9576749 15000000 I90200 NOV 10, 2015 3:27 PM SOFTWARE REVISION LEVEL VERSION 329.00 SOFTWARE# 346329-100-A CREATED - 08.10.09.17.08 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD I11100 NOV 10, 2015 3:27 PM 189413 DOWNTOWN CHEV 2317 L ST. BAKERSFIELD,CA PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME L 9 DISP PAN PAN 19-20 FUEL ALARM CLEAR 11-10-15 1:27PM L 9 DISP PAN PAN 19-20 FUEL ALARM ALARM 11-10-15 1:26PM L 7 DISP PAN PAN 15-16 FUEL ALARM CLEAR 11-10-15 1:25PM L 7 DISP PAN PAN 15-16 FUEL ALARM ALARM 11-10-15 1:25PM L10 DISP PAN PAN 13-14 FUEL ALARM CLEAR 11-10-15 1:23PM L10 DISP PAN PAN 13-14 FUEL ALARM ALARM 11-10-15 1:22PM L 8 DISP PAN PAN 17-18 FUEL ALARM CLEAR 11-10-15 1:20PM L 8 DISP PAN PAN 17-18 FUEL ALARM ALARM 11-10-15 1:20PM L 6 ANNULAR 91 DSL ANN FUEL ALARM CLEAR 11-10-15 1:17PM L 6 ANNULAR 91 DSL ANN FUEL ALARM ALARM 11-10-15 1:09PM L 2 ANNULAR 89-87 ANN FUEL ALARM CLEAR 11-10-15 1:07PM L 2 ANNULAR 89-87 ANN FUEL ALARM ALARM 11-10-15 1:07PM L 3 STP SUMP 87 STP FUEL ALARM CLEAR 11-10-15 1:05PM L 3 STP SUMP 87 STP FUEL ALARM ALARM 11-10-15 1:04PM L 3 STP SUMP 87 STP FUEL ALARM CLEAR 11-10-15 12:57PM L 3 STP SUMP 87 STP FUEL ALARM ALARM 11-10-15 12:57PM L 3 STP SUMP 87 STP SENSOR OUT ALARM CLEAR 11-10-15 12:56PM L 3 STP SUMP 87 STP SENSOR OUT ALARM ALARM 11-10-15 12:54PM L 5 STP SUMP DSL STP FUEL ALARM CLEAR 11-10-15 12:47PM L 5 STP SUMP DSL STP FUEL ALARM ALARM 11-10-15 12:47PM L 4 STP SUMP 91 STP FUEL ALARM CLEAR 11-10-15 12:46PM L 4 STP SUMP 91 STP FUEL ALARM ALARM 11-10-15 12:46PM L 1 STP SUMP 89 STP FUEL ALARM CLEAR 11-10-15 12:45PM L 1 STP SUMP 89 STP FUEL ALARM ALARM 11-10-15 12:45PM T 1 TANK PLUS PROBE OUT CLEAR 11-10-15 12:44PM T 1 TANK PLUS OVERFILL ALARM CLEAR 11-10-15 12:44PM T 1 TANK PLUS PROBE OUT ALARM 11-10-15 12:44PM T 1 TANK PLUS OVERFILL ALARM ALARM 11-10-15 12:43PM T 2 TANK UNLEADED PROBE OUT CLEAR 11-10-15 12:42PM T 2 TANK UNLEADED OVERFILL ALARM CLEAR 11-10-15 12:41PM T 2 TANK UNLEADED PROBE OUT ALARM 11-10-15 12:41PM T 2 TANK UNLEADED OVERFILL ALARM ALARM 11-10-15 12:41PM T 3 TANK SUPREME PROBE OUT CLEAR 11-10-15 12:40PM T 3 TANK SUPREME PROBE OUT ALARM 11-10-15 12:40PM L 4 STP SUMP 91 STP SENSOR OUT ALARM CLEAR 11-10-15 12:39PM L 3 STP SUMP 87 STP SENSOR OUT ALARM CLEAR 11-10-15 12:39PM L 2 ANNULAR 89-87 ANN SENSOR OUT ALARM CLEAR 11-10-15 12:39PM L 8 DISP PAN PAN 17-18 SENSOR OUT ALARM CLEAR 11-10-15 12:39PM L 7 DISP PAN PAN 15-16 SENSOR OUT ALARM CLEAR 11-10-15 12:39PM L 6 ANNULAR 91 DSL ANN SENSOR OUT ALARM CLEAR 11-10-15 12:39PM L 1 STP SUMP 89 STP SENSOR OUT ALARM CLEAR 11-10-15 12:39PM L 5 STP SUMP DSL STP SENSOR OUT ALARM CLEAR 11-10-15 12:39PM L10 DISP PAN PAN 13-14 SENSOR OUT ALARM CLEAR 11-10-15 12:39PM L 9 DISP PAN PAN 19-20 SENSOR OUT ALARM CLEAR 11-10-15 12:39PM L 8 DISP PAN PAN 17-18 SENSOR OUT ALARM ALARM 11-10-15 12:38PM L 7 DISP PAN PAN 15-16 SENSOR OUT ALARM ALARM 11-10-15 12:38PM L 6 ANNULAR 91 DSL ANN SENSOR OUT ALARM ALARM 11-10-15 12:38PM L 4 STP SUMP 91 STP SENSOR OUT ALARM ALARM 11-10-15 12:38PM L 3 STP SUMP 87 STP SENSOR OUT ALARM ALARM 11-10-15 12:38PM L 2 ANNULAR 89-87 ANN SENSOR OUT ALARM ALARM 11-10-15 12:38PM I11200 NOV 10, 2015 3:27 PM 189413 DOWNTOWN CHEV 2317 L ST. BAKERSFIELD,CA NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 4 TANK DIESEL HIGH PRODUCT ALARM CLEAR 11-10-15 3:27PM T 4 TANK DIESEL HIGH PRODUCT ALARM ALARM 11-10-15 3:25PM OTHER ISD GROSS PRES WARN CLEAR 11-10-15 1:59PM T 1 TANK PLUS LOW TEMP WARNING CLEAR 11-10-15 12:46PM T 1 TANK PLUS LOW TEMP WARNING ALARM 11-10-15 12:44PM T 2 TANK UNLEADED HIGH PRODUCT ALARM CLEAR 11-10-15 12:41PM T 2 TANK UNLEADED HIGH PRODUCT ALARM ALARM 11-10-15 12:41PM T 3 TANK SUPREME HIGH PRODUCT ALARM CLEAR 11-10-15 12:40PM T 3 TANK SUPREME HIGH PRODUCT ALARM ALARM 11-10-15 12:40PM T 1 TANK PLUS INVALID FUEL LEVEL CLEAR 11-10-15 12:22PM T 1 TANK PLUS DELIVERY NEEDED CLEAR 11-10-15 12:22PM T 1 TANK PLUS DELIVERY NEEDED ALARM 11-10-15 12:22PM T 1 TANK PLUS INVALID FUEL LEVEL ALARM 11-10-15 12:22PM OTHER ISD GROSS PRES WARN ALARM 11-10-15 10:01AM SYSTEM PRINTER ERROR CLEAR 11-10-15 9:15AM SYSTEM PAPER OUT CLEAR 11-10-15 9:15AM SYSTEM PRINTER ERROR ALARM 11-10-15 9:15AM SYSTEM PAPER OUT ALARM 11-10-15 9:15AM h 6 OTHER FP6: BLEND3 DEGRD COLLECT WARN CLEAR 11-09-15 4:20PM h 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN CLEAR 11-09-15 10:00AM h 1 OTHER FP1: BLEND3 DEGRD COLLECT WARN CLEAR 11-09-15 10:00AM h 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN ALARM 11-08-15 10:01AM h 1 OTHER FP1: BLEND3 DEGRD COLLECT WARN ALARM 11-08-15 10:01AM h 1 OTHER FP1: BLEND3 DEGRD COLLECT WARN CLEAR 11-07-15 10:00AM h 6 OTHER FP6: BLEND3 DEGRD COLLECT WARN ALARM 11-06-15 10:03AM h 1 OTHER FP1: BLEND3 DEGRD COLLECT WARN ALARM 11-06-15 10:03AM OTHER ISD GROSS PRES WARN CLEAR 11-03-15 5:34PM SYSTEM PRINTER ERROR CLEAR 11-03-15 10:04AM SYSTEM PAPER OUT CLEAR 11-03-15 10:04AM SYSTEM PAPER OUT ALARM 11-03-15 10:04AM SYSTEM PRINTER ERROR ALARM 11-03-15 10:04AM OTHER ISD GROSS PRES WARN ALARM 11-03-15 10:03AM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN CLEAR 11-02-15 10:00AM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN ALARM 11-01-15 10:04AM h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN CLEAR 10-23-15 12:06PM h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN ALARM 10-22-15 10:05AM h 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN CLEAR 10-20-15 10:00AM h 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN ALARM 10-18-15 10:06AM h 1 OTHER FP1: BLEND3 DEGRD COLLECT WARN CLEAR 10-13-15 10:00AM h 1 OTHER FP1: BLEND3 DEGRD COLLECT WARN ALARM 10-12-15 10:05AM h 1 OTHER FP1: BLEND3 DEGRD COLLECT WARN CLEAR 10-11-15 10:00AM h 1 OTHER FP1: BLEND3 DEGRD COLLECT WARN ALARM 10-10-15 10:04AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN CLEAR 10-06-15 10:00AM SYSTEM PRINTER ERROR CLEAR 10-06-15 3:06AM SYSTEM PRINTER ERROR ALARM 10-06-15 3:06AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN ALARM 10-05-15 10:05AM SYSTEM PRINTER ERROR CLEAR 9-26-15 12:10AM SYSTEM PAPER OUT CLEAR 9-26-15 12:10AM SYSTEM PRINTER ERROR ALARM 9-26-15 12:08AM SYSTEM PAPER OUT ALARM 9-26-15 12:08AM I20600 NOV 10, 2015 3:27 PM 189413 DOWNTOWN CHEV 2317 L ST. BAKERSFIELD,CA TANK ALARM HISTORY TANK 1 PLUS OVERFILL ALARM NOV 10, 2015 12:43 PM LOW PRODUCT ALARM NOV 10, 2015 12:22 PM INVALID FUEL LEVEL NOV 10, 2015 12:22 PM PROBE OUT NOV 10, 2015 12:44 PM NOV 10, 2015 12:21 PM DELIVERY NEEDED NOV 10, 2015 12:22 PM LOW TEMP WARNING NOV 10, 2015 12:44 PM TANK 2 UNLEADED OVERFILL ALARM NOV 10, 2015 12:41 PM OCT 18, 2015 2:58 AM OCT 7, 2015 9:05 PM HIGH PRODUCT ALARM NOV 10, 2015 12:41 PM PROBE OUT NOV 10, 2015 12:41 PM NOV 10, 2015 12:20 PM SEP 14, 2015 1:30 PM LOW TEMP WARNING SEP 14, 2015 1:33 PM TANK 3 SUPREME LOW PRODUCT ALARM JUN 8, 2015 10:04 AM HIGH PRODUCT ALARM NOV 10, 2015 12:40 PM INVALID FUEL LEVEL JUN 8, 2015 10:12 AM PROBE OUT NOV 10, 2015 12:40 PM NOV 10, 2015 12:18 PM JUN 15, 2015 6:59 AM DELIVERY NEEDED JUN 8, 2015 9:51 AM TANK 4 DIESEL HIGH PRODUCT ALARM NOV 10, 2015 3:25 PM I38200 NOV 10, 2015 3:27 PM I30200 NOV 10, 2015 3:27 PM 189413 DOWNTOWN CHEV 2317 L ST. BAKERSFIELD,CA LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 89 STP NOV 10, 2015 12:45 PM FUEL ALARM NOV 10, 2015 12:38 PM SENSOR OUT ALARM JUN 29, 2015 9:01 AM FUEL ALARM 2 89-87 ANN NOV 10, 2015 1:07 PM FUEL ALARM NOV 10, 2015 12:38 PM SENSOR OUT ALARM JUN 29, 2015 8:37 AM FUEL ALARM 3 87 STP NOV 10, 2015 1:04 PM FUEL ALARM NOV 10, 2015 12:57 PM FUEL ALARM NOV 10, 2015 12:54 PM SENSOR OUT ALARM 4 91 STP NOV 10, 2015 12:46 PM FUEL ALARM NOV 10, 2015 12:38 PM SENSOR OUT ALARM JUN 29, 2015 8:36 AM FUEL ALARM 5 DSL STP NOV 10, 2015 12:47 PM FUEL ALARM NOV 10, 2015 12:38 PM SENSOR OUT ALARM JUN 29, 2015 8:52 AM FUEL ALARM 6 91 DSL ANN NOV 10, 2015 1:09 PM FUEL ALARM NOV 10, 2015 12:38 PM SENSOR OUT ALARM JUN 29, 2015 9:04 AM FUEL ALARM 7 PAN 15-16 NOV 10, 2015 1:25 PM FUEL ALARM NOV 10, 2015 12:38 PM SENSOR OUT ALARM JUN 29, 2015 9:39 AM FUEL ALARM 8 PAN 17-18 NOV 10, 2015 1:20 PM FUEL ALARM NOV 10, 2015 12:38 PM SENSOR OUT ALARM JUN 29, 2015 9:40 AM FUEL ALARM 9 PAN 19-20 NOV 10, 2015 1:26 PM FUEL ALARM NOV 10, 2015 12:38 PM SENSOR OUT ALARM AUG 24, 2015 2:42 PM SENSOR OUT ALARM 10 PAN 13-14 NOV 10, 2015 1:22 PM FUEL ALARM NOV 10, 2015 12:38 PM SENSOR OUT ALARM JUN 22, 2015 7:49 AM SENSOR OUT ALARM I31600 NOV 10, 2015 3:27 PM 189413 DOWNTOWN CHEV 2317 L ST. BAKERSFIELD,CA SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 FM 13-14 JUN 3, 2015 10:41 AM COMMUNICATION ALARM 2 FM 15-16 JUN 3, 2015 11:22 AM COMMUNICATION ALARM 3 FM 17-18 JUN 3, 2015 10:36 AM COMMUNICATION ALARM 4 FM 19-20 JUN 3, 2015 10:49 AM COMMUNICATION ALARM 8 PS 19-20 JUN 3, 2015 10:46 AM COMMUNICATION ALARM I40200 NOV 10, 2015 3:27 PM I40300 NOV 10, 2015 3:27 PM I34200 NOV 10, 2015 3:27 PM I34700 NOV 10, 2015 3:27 PM IV0100 NOV 10, 2015 3:27 PM 189413 DOWNTOWN CHEV 2317 L ST. BAKERSFIELD,CA ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.02 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :WARN EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :WARN ISD MONITOR UP-TIME :100% STAGE I TRANSFERS: 0 of 0 NOTEST EVR/ISD PASS TIME : 0% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 15-11-10 10:01:30 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.64 15-11-08 10:01:59 A/L RATIO DEGRADATION FP 6 BLEND3 0.76 15-11-08 10:01:59 A/L RATIO DEGRADATION FP 5 BLEND3 0.80 15-11-08 10:01:59 A/L RATIO DEGRADATION FP 1 BLEND3 0.81 15-11-07 10:03:12 A/L RATIO DEGRADATION FP 6 BLEND3 0.76 15-11-06 10:03:18 A/L RATIO DEGRADATION FP 6 BLEND3 0.80 15-11-06 10:03:18 A/L RATIO DEGRADATION FP 1 BLEND3 0.80 15-11-03 10:03:55 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.40 15-11-01 10:04:17 A/L RATIO DEGRADATION FP 7 BLEND3 0.78 15-10-23 10:04:51 A/L RATIO DEGRADATION FP 3 BLEND3 0.79 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 15-09-09 10:06:19 A/L RATIO DEGRADATION FP 6 BLEND3 0.76 15-06-23 10:01:09 SENSOR OUT SELFTEST s 8 15-06-23 10:01:09 SENSOR OUT SELFTEST s 4 15-06-23 10:01:09 SETUP SELFTEST MISSING SHUTDOWN RELAY(S) 15-06-22 10:01:09 SENSOR OUT SELFTEST s 8 15-06-22 10:01:09 SENSOR OUT SELFTEST s 4 15-06-22 10:01:09 SENSOR OUT SELFTEST s 3 15-06-22 10:01:09 SENSOR OUT SELFTEST s 2 15-06-22 10:01:09 SENSOR OUT SELFTEST s 1 15-06-22 10:01:09 SETUP SELFTEST MISSING SHUTDOWN RELAY(S) SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 15-11-10 13:59:12 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 15-11-10 12:37:50 READINESS ISD:PP EVR:NN EVR READINESS PENDING 15-11-10 12:37:50 ISD STARTUP 15-11-10 12:36:42 ISD SHUTDOWN 15-11-09 16:20:24 COLLECTION TEST HH06 GRADE TEST MANUALLY CLEARED 15-11-03 17:34:34 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 15-11-01 01:00:00 TIME CHANGE DETECTED AT: 15-11-01 02:00:13 15-10-23 12:06:41 COLLECTION TEST HH03 GRADE TEST MANUALLY CLEARED 15-09-14 14:28:45 COLLECTION TEST HH06 GRADE TEST MANUALLY CLEARED 15-09-14 14:28:37 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED SWRCB, January 2006 Spill Bucket Testing Report Form This form is intended for use by contractors performing annual testing of UST spill containment structures. The completed form and printouts from tests (if applicable), should be provided to the facility owner/operator forsubmittal to the local regulatory agency. 1.FACILITY INFORMATION Facility Name:Date of Testing: Facility Address: Facility Contact:Phone: Date Local Agency Was Notified of Testing : Name of Local Agency Inspector (if present during testing): 2.TESTING CONTRACTOR INFORMATION Company Name:Confidence UST Services, Inc. Technician Conducting Test: Credentials1:CSLB Contractor ICC Service Tech. SWRCB Tank Tester Other (Specify) License Number(s):CSLB#804904 ICC# 3.SPILL BUCKET TESTING INFORMATION Test Method Used:Hydrostatic Vacuum Other Test Equipment Used:Lake TestEquipment Resolution:0.0625” Identify Spill Bucket (By Tank Number, Stored Product, etc.) 1234 Bucket Installation Type: Direct Bury Contained in Sump Direct Bury Contained in Sump Direct Bury Contained in Sump Direct Bury Contained in Sump Bucket Diameter: Bucket Depth: Wait time between applying vacuum/water and start of test: Test Start Time (TI): Initial Reading (RI): Test End Time (TF): Final Reading (RF): Test Duration (TF – TI): Change in Reading (RF -RI): Pass/Fail Threshold or Criteria: Test Result: Pass Fail Pass Fail Pass Fail Pass Fail Comments –(include information on repairs made prior to testing, and recommended follow-up for failed tests) CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING I hereby certify that all the information contained in this report is true, accurate, and in full compliance with legal requirements. Technician’s Signature:________________________________________________ Date:_________ 1 State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements may be more stringent. Sully'sDowntown(North)11/10/2015 2317LStreet Bakersfield,CA93301 FrankSullivan(661)327-5008 11/3/2015 Kris Karns DustinReese 8216722-UT Regular 12.00" 11.75" 5min. 12:00 pm 9.75" 1:00 pm 9.75" 1hour 0.00" 0.0625" Plus 12.00" 12.25" 5min. 12:00 pm 10.25" 1:00 pm 10.25" 1hour 0.00" 0.0625"0.0625" Super 12.00" 12.00" 5min. 12:00 pm 10.25" 1:00 pm 10.25" 1hour 0.00" Diesel 12.00" 12.25" 5min. 12:00 pm 10.75" 1:00 pm 10.75" 1hour 0.00" 0.0625" 11/10/2015