HomeMy WebLinkAboutSB989 2014TA INT I A LUING£ 7 14! 5 6 2 2 2 September 23, 2014 VIA FED EX 7712 4837 4540 Bakersfield Fire Department 2101 H Street Bakersfield CA 93301 Re: Secondary Containment Testing Pacific Bell Telephone Co. dba AT&T California 1918 "Mvv STREET, BAKERSFIELD5 CA GEOPAR: SA004 To Whom It May Concern: 2 3 CA 9,�"(;6 Enclosed are the results for the following tests completed on September 19, 2014: ■ Secondary Containment Testing Report Form Please do not hesitate to call me if you have any questions. Very, Truj;v Yours ar4losE. Cardenas Program Manager CA lics 588098 1; AZ hc# 0959 84 "r NV lic�,'; 0049666 1 TX lica CPQOv0041 Secondary Containment Testing Report Form This form is intended for use by contractors performing periodic testing of UST secondary containment systems. Use the appropriate pages of this form to report results for all components tested. The completed form, written test procedures, and printouts from tests (if applicable), should be provided to the facility owner /operator for submittal to the local regulatory agency. . err .m 7 W kTV1d'%"%/V ♦ TYd -%XT C.,,.;l,+- TTI• C' A OOA Facili Name: Pacific Bell Telephone Co. dba AT &T California Date of Testing: 9/19/2014 Facility Address: 1918 M STREET, Bakersfield, CA 93301 Facility Contact: Grant Armstrong Phone: (661) 327 -6903 r— Initial - Repair Test Date Local Agency Was Notified Of Testing: 9/16/2014 - 6 Month r— Other Name of Local Agency Inspector (if present during testing): Shane Gardner Tri ennial m C1nrV%Td" rd-%XM D A d -rlrnD irwr D x4ATMN Company Name: Tait Environmental Services Technician Conducting Test: Adolfo Aguilar Credentials: CSLB Licensed Contractor SWRCB Licensed Tank Tester ICC UST Service Technician License Type: A B AS C -10 HAZ I License Number: 588098 Repairs Made Man ufactu rer T raining_ Pass Manufacturer Component(s) Repairs Made Date Training Expires ICC Technician 5238610 6/17/2016 _ Franklin Fueling / Incon TS -STS 1732573702 r7 7/14/2016 _ I crTlt4A4At2V nlP TF.CTRFCTTI,T If hydrostatic testing was performed, describe what was done with the water after completion of tests: _..__w...,.- . -- --- r .._. .. w..,... ......w........_ ............... . w...__......_.... ,. Took Non -Haz. Test Water To TAIT Shop. For .............................................................................................. ............................... any equipment capable of generating a print out of test results, you must attach a copy of the test report to this certification System printout attached. CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING To the best of my knowledge, the facts stated in this document are accurate and in full compliance with legal requirements Technician's Signature: Date: 9/19/2014 Companent Pass Fail Not Tested Repairs Made Component Pass Fail Not Tested Repairs Made Fill Sump SA004UO01 F r7 r7 r r r— I— F r F f r7 r 17 r If hydrostatic testing was performed, describe what was done with the water after completion of tests: _..__w...,.- . -- --- r .._. .. w..,... ......w........_ ............... . w...__......_.... ,. Took Non -Haz. Test Water To TAIT Shop. For .............................................................................................. ............................... any equipment capable of generating a print out of test results, you must attach a copy of the test report to this certification System printout attached. CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING To the best of my knowledge, the facts stated in this document are accurate and in full compliance with legal requirements Technician's Signature: Date: 9/19/2014 o rrr r nrcro rnNTA 1NA41P.NT CTT1ViP TFIRTTNG Facility is Not Equipped With Fill Riser Containment Sumps Fill Riser Containment Sumps are present, but were Not Tested Test Method Developed By: F ' Sump Manufacturer Industry Standard F Professional Engineer Other(Specify) Test Method Used: F Pressure r Vacuum F1 Hydrostatic Other(Specify) Test Equipment Used: Incon TS -STS Equipment Resolution: u `$ ill Sump Fill S ump Fill SA004U00I Sump Diameter: 48" .0006 Fill Sump Fill Sump Sump Depth: 54" Height from Tank Top to Top of Highest Piping Penetration: 2511 Height from Tank Top to Lowest Electrical Penetration: 35" Condition of sump prior to testing : Portion of Sump Tested: Excellent 2" above penetration Sump Material: Fiberglass Wait time between applying pressure /vacuum /water and st arti ng test: 15 Minutes Test Start Time: 9:15 AM 9:30 AM Initial Reading (RI): 6.6625" 6.6622" Test End Time: 9:30 AM 9:45 AM Final Reading (RF): 6.6621" 6.6618" Test Duration: Change in Reading (RF-RI): 15 Min. 15 Min. .0004" .0004" Pass/Fail Threshold or Criteria: .002" .002" Test Result: Pass Fail Pass Fail Pass F' Fail Pass Fail Is there a sensor in the sump? V Yes r No F Yes No r Yes f No Yes No Does the sensor alarm when either product or water is detected ?; Was sensor removed for testing? r Yes '" No NA v ! y� No NA Yes No NA Yes 1 No NA Yes No NA Yes' No NA "' Yes No NA Yes No ! NA Was sensor properly replaced and verified functional after testing? Yes No NA Yes No NA Yes No NA Yes ' No ! :NA Comments - (include information on repairs made prior to testing, and recommended follow -up for failed tests) Re- Installed Sensor To Lowest Point But Not Tested. ATT SA004 1918 M. ST, BAKERSFIELD CALIFORNIA TAIT ENVIRONMENTAL 09/19/2014 9:30 AM SUMP LEAK TEST REPORT FILL TEST STARTED 9:15 AM TEST STARTED 09/19/2014 BEGIN LEVEL 6,6625 IN END TIME 9:30 AM END DATE 09/19/2014 END LEVEL 6.6621 IN LEAK THRESHOLD 0,002 IN TEST RESULT PASSED ATT SA004 1918 M. ST, BAKERSFIELD CALIFORNIA TAIT ENVIRONMENTAL 09/19/2014 9:45 AN SUMP LEAK TEST REPORT FILL TEST STARTED 9:30 AM TEST STARTED 09/19/2014 BEGIN LEVEL 6,6622 IN END TIME 9:45 AM END DATE 09/19/2014 END LEVEL 6.6618 IN LEAK THRESHOLD 0,002 IN TEST RESULT PASSED TEST DATE: 9/19/2014 CLIENT: AT &T GEOPAR: SA004 PAGE J- OF �---