Loading...
HomeMy WebLinkAboutCUPA Report 2013Facility Name: Fastbreak Mobil Date of Inspection: Time In: Time Out: Address: White Lane Bakersfield, CA 933 Inspected by: Ernie Medina ICC# 8012428 -Ul Contact: Firoz Daredia Ty o I ns pectio n: XA, Compliance ❑Re- inspection om laint Phone: (661) 1- 8103 (4 r.) Permis for Inspection Granted by: Tank ID #1 #2 #3 #4 Size 10,000 10,000 10,000 10; 000 Contents REG. MID PREM DSL' Construction SW CP SW CP SW CP SW CP Tank Monitoring: DW: Continuous Interstitial Monitoring Dry El Brine/Hydrostatic ❑ Vacuum /Pressure. r� J'L' SW: SIR and Line Test every 2 years. El El ❑ ❑ SW: ATG 0.1 annual. ❑ ❑ ❑ ❑ SW: ATG 0.2 monthly. ❑ ❑ ❑ ❑ SW: Continuous In -Tank Leak Detection (CITLD). ❑ ❑ ❑ ❑ SW: Tank Gauging. ❑ ❑ ❑ ❑ - SW: Vadose /GW Monitoring. ❑ ❑ ❑ ❑ Other Description: ❑ ❑ ❑ ❑ Piping Monitoring: DW Suction: Continuous Interstitial at UDC and Tank Sump. ❑ ❑ ❑ ❑ DW Pressurized: Interstitial at UDC and Turbine Sump and 3.0 gph LLD, ❑ Annual Line Test or ❑ Auto - shutdown and Failsafe. ❑ o ❑ 0 DW VPH Monitoring: Includes lines, sumps, fill pipe, vapor lines, etc. ❑ ❑ ❑ ❑ SW Conventional Suction: Triennial 0.1 gph line test., and daily monitoring. ❑ F-1 ❑ El SW Pressurized: Line 0.1 gph annual or 0.2 gph monthly line test and LLD with Auto - Shutdown. ❑ ❑ ❑ E SW or DW Safe Suction. ❑ ❑ ❑ ❑ SW: Vadose Zone or GW Monitoring. ❑ ❑ ❑ ❑ DW or SW: Gravity Flow Pipe. ❑ ❑ ❑ ❑ Other Description: ❑ ❑ ❑ ❑ References to the Health and Safety Code, the California Code of Regulations and the Code of Federal Regulations throughout this Appendix are intended to be useful but are not necessarily exhaustive of all legal references that might apply or be relevant to a specific compliance determination. Laws and regulations are subject to change, so the references contained herein may not be up to date. It is the responsibility of the owner and operator to know and comply with all applicable legal requirements. UNDERGROUND STORAGE TANK COMPLIANCE INSPECTION REPORT Fa..c.ility Name: Date: Bakersfield Fire Department — Prevention Services Division, 2101 H Street, Bakersfield, CA 93301 (661) 326-3979 If in compliance, check the box. Check NA if not applicable. If a violation, determine if Minor, Class 11, or Class 1, or To Violations Be Determined (TBD) if uncertain and will be determined later. '7 3511, "'U Q File Review i UST Permit to Operate is current. HSC 25284(a), 25299(a)(1) 25299 (b)(1) El ❑ 2 Transfer of permit and/or change of information provided within 1 30 days of ownership/information changes. HSC 25284(b) (c); T23 KI CCR 2712(d) ;93 UST form information current/correct for facility, including BOE number. HSC 25286(a) 04 Fees are paid up-to-date. HSC25285(c), 25287 ,195 Monitoring Plan approved for current owner with appropriate El content and level of detail. T23 CCR 2632(d), 2634 (d), 2641(h) -)(6— Current Emergency Response Plan submitted with appropriate content and level of detail. T23 CCR 2632(d), 2634 (d), 2641(h) ISZ7 Plot Plan/Site Map submitted with appropriate content and E� level of detail. T23 CCR 2632(d), 2634(d), 2641(h), 2711(a)(9) 1 %8 owner/operator agreement submitted, if required. HSC 25284(a)(3) El 9 Certification of Compliance and Designated Operator 171 Certification submitted by current tank owner. T23 CCR 2715 1-0 Certificate of Financial Responsibility submitted and is current for the permit period. HSC 25292.2,25299.30-25299.34; T23 CCR 2711; 2808.1; El 2809-2809.2 p611 Monitoring system certification (most recent) conducted within allowable timeframe (sensors and console). Results submitted El and show all required components with passing results. HSC 25284.1 a 4 c ; T23 CCR 2638 Spill-bucket test results (most recent) conducted within ,X12 allowable time frame. Results submitted and indicate a passing El test. HSC 25284.2 pfl _3 Leak Detector testing conducted within allowable time frame. The most recent annual certification submitted and shows RD RD RD RD passing results. 40 CFR 280.40(a)(2),280.43(g)(I)&(2),280.44(a); HSC 25292(e); T23 CCR 2638, 2641 ' 1 A4 Secondary containment testing conducted within allowable time frame. Most recent testing results submitted and indicate a passing test. HSC 25284.1(a)(4)(8); T23 CCR 2637(a) ❑15 Pipe and/or tank integrity testing conducted within allowable time frame. Most recent testing results submitted and indicate passing results. 40 CFR 280.33, 280.40, 280.41, 280.44; T23 CCR 26360, 2643(b)(3), (c)(3), (d) (je ❑16 Repaired tanks/piping are tightness tested within 30 days of RD RD RD RD the repair. 40 CFR 280.33; T23 CCR 2661 7 ELD test conducted within allowable time frame. Most recent test results submitted and passing results achieved. T23 CCR El 2644.1 1_8 The corrosion protection system is checked by a corrosion Z specialist within six months of instal lation/repair and at least every three years thereafter; results show protection to be RP RP RP RP L JI adequate. Impressed current inspected every 60-calendar days. 40 CFR 280.31, 280.70, T23 CCR 2635(a)(2) 17-9 Tank Lining recertification is current (within 10 years of lining and every 5 years thereafter) and compliant. 40CFR280.21(b)(1)(fi,); RP El T23 CCR 2663(h) RP RP RP Bakersfield Fire Department — Prevention Services Division, 2101 H Street, Bakersfield, CA 93301 (661) 326-3979 UNDERGROUND STORAGE TANK COMPLIANCE INSPECTION REPORT F&Jlitv Name: Date: MMMIN RP RP RP RP E ��mm RP RP RP ri Cf On-Site Review This Inspection is being conducted during the annual monitoring certification. '''YES ONO The service technician has provided ICC Certification and manufacturers training documentation, and possesses a tank tester's license or works under a CSLB contractor's license. OYES L7 NO I W c It b I bh b g.4 General X20 Tank systems meet current construction standards as required for type of system. HSC 25288 ;ivi Hazardous substance tanks have secondary containment. 40 CFR 280.42(b); T23 CCR 2631 X2 Electronic monitoring system has audible and visual alarm in operating condition. T23 CCR 2632, 2634, 2636 023 Monitor console programmed appropriately for monitoring option used. T23 CCR 2638, 2643, 2643.1 ❑24 Tank systems in temporary closure meet requirements. 40 CFR 280.70, T23 CCR 2670 & 2671 ❑25 Overfill Prevention mechanism present and operational according to type: ❑Flapper valve % Audible-visual alarm ❑ball float. ❑ AN alarm and Ball Float 40 CFR 280.20(c)(1)(fl), 280.21(d); T23 CCR 2635(b)(2), 2631(d)(4) ❑26 Spill prevention device is present and functional (in good condition and drain mechanism operational if applicable). 40 CFR 280.20(c)(1)(1), 280.21(d); T23 CCR 2635(b)(1);2665 ❑27 Piping and piping penetration boots within sumps/UDC are in qood condition. HSC 25288(a), 25292.1 5928 All sumps, spill buckets, and UDC's free from debris and liquid. HSC 25291(e), 25290.1, 25290.2; T23 CCR 2635(b)(1)(C) A9 Areas around vents appear to be free from signs of liquid releases. HSC 25288(a), 25290.1, 25290.2, 25295.5 I 1430 Release Detection methods are present and meet performance standards. See LG-1 13. 40 CFR 280.40(a)(3) W1 All sensors are correct for the type of system and operational. 40 CFR 280.40(a)(2), 280.43(g)(1)&(2); HSC 25290.1 e , 25290.2, 25291; T23 CCR 2638 All sensors are located in the proper position/location. 40 CFR J$32 280.40(a)(2), 280.43(g)(1)&(2); HSC 25290.1, 25290.2, 25291; T23 CCR 2630(d); 2632(c);264 I (ja .W33 All secondary containment, including UDC shall be equipped with a continuous monitoring system that either activates an A/V alarm or stops the flow of product at the dispenser when it detects a leak. T23 CCR 2636 (0(1) Tank Monitoring ❑34 ❑ Interstitial monitoring conducted properly. 40 CFR 280.40(a)(2), 280.43(g) 1)&(2); T23 CCR 2632 (c)(2); 2634(d)(1) ❑35 ❑ VPH monitoring conducted properly. HSC 25290.1 O SIR ❑36 SIR and Biennial 0.1 gph tank test performed properly. 40 CFR 280.41, 280.43; T23 CCR 2643, 2646.1 ❑37 Non-passing SIR monitoring report results are reported and investigated properly. 40 CFR 280.41(a), 280.43(h)(1),(2); T23 CCR 2646.1 ..... MMMIN RP RP RP RP E ��mm RP RP RP O IMENE EMMEE F1 MMMIN RP RP RP RP RP RP RP RP L J F1 ®®W® N OWWW O He M'.. MME U_0e_,5 ow�/ Bakersfield Fire Department — Prevention Services Division, 2101 H Street, Bakersfield, CA 93301 (661) 326-3979 UNDERGROUND STORAGE TANK COMPLIANCE INSPECTION REPORT Facility Name: i Date: O Line Integrity Testing 051 SW pressurized piping: annual 0.1 gph line integrity test or a monthly 0.2 gph line integrity test is performed properly. 40 CFR RD RD RD RD El 280.41, 280.44; T23 CCR 2643(c)(2),(3) ❑52 SW conventional suction system: 0.1 gph line integrity test is RD RD RD RD performed every three nears. 40 CFR 280.40,280.41; T23 CCR 2643(d) Bakersfield Fire Department — Prevention Services Division, 2101 H Street, Bakersfield, CA. 93301 (661) 326 -3979 O Automatic Tank Gauging (ATG) / Continuous In -Tank Leak 044 Detection CITLD 038 ATG or CITLD 0.2 gph monthly test performed properly. 40 CFR RD RD RD RD ❑ '7 � � +� 280.43; T23 CCR 2643(b)(1), 2643(4)(5 ) b ,K39 ATG generates a hard copy printout of all data reported ;10/3 dvg 74�' 45 including time and date, tank I. D., fuel depth, water depth, temperature, liquid volumfa and duration of test. If installed after El 1/1/95 printout includes calculated leak rate and leak threshold. T23 CCR 2643 b 1 046 O Manual Tank Gauging SW tanks </ =1000 gal. ONLY) 040 Weekly manual tank gauging performed properly. 40 CFR 280.43; RD RD RD RD A T23 CCR 2645 041 Tank Integrity test performed, if necessary. 40 CFR 280.43, T23 CCR RD RD RD RD 2645 , O Vadose Zone and /or Groundwater Monitoring RD RD RD RD El 042 Monitoring system is installed and monitored properly. 40 CFR RD RD RD RD 280.43; T23 CCR 2647 -48 OTank Exemption 043 Tanks /piping meet tank exemption criteria, and weekly visual ❑48 monitoring records are kept up-do-date. HsC 25283.5 Pipe Monitoring RD RD RD RD J, O Line Integrity Testing 051 SW pressurized piping: annual 0.1 gph line integrity test or a monthly 0.2 gph line integrity test is performed properly. 40 CFR RD RD RD RD El 280.41, 280.44; T23 CCR 2643(c)(2),(3) ❑52 SW conventional suction system: 0.1 gph line integrity test is RD RD RD RD performed every three nears. 40 CFR 280.40,280.41; T23 CCR 2643(d) Bakersfield Fire Department — Prevention Services Division, 2101 H Street, Bakersfield, CA. 93301 (661) 326 -3979 O Continuous Monitoring System 044 DW piping (gravity, suction, pressure) in the turbine sump has continuous monitoring system that activates an audible and RD RD RD RD visual alarm or restricts or stops flow at dispenser. T23 CCR 2636 (0(1) 45 DW piping in the UDC is continuously monitored and method either shuts down the flow of product to the dispenser or El activates an AN alarm. T23 CCR 26361(1) O Line Integrity Testing for Pressurized Piping 046 An annual 0.1 gph line integrity test is performed properly. (Either third party or by Enhanced Line Leak Detection) T23 CCR RD RD RD RD A 2636 (0(4) ,X47 In lieu of the annual tightness test for DW pressurized piping, the monitoring system for all product piping outside the dispenser is fail -safe and shuts down the pump when a leak is RD RD RD RD El detected and the monitoring system shuts down the pump or flow restriction occurs when a leak is detected in the UDC. T23 CCR 26360(5) O Line Leak Detectors (LLD) ❑48 LLD's installed, annually tested, and operational on DW pressurized piping that detects a 3.0 -gph leak, and restricts or RD RD RD RD J, shuts off flow of product. T23 CCR 26360(2) O DW Emergency Generator Tank ❑49 LLD activates AN alarm and monitoring system is checked RD RD RD RD daily. T23 CCR 26360(2) 050 In lieu of LLD, continuous monitoring system of DW emergency generator tank activates AN alarm, system is checked daily, and loos are kept. T23 CCR 2636 (0(6) O Line Integrity Testing 051 SW pressurized piping: annual 0.1 gph line integrity test or a monthly 0.2 gph line integrity test is performed properly. 40 CFR RD RD RD RD El 280.41, 280.44; T23 CCR 2643(c)(2),(3) ❑52 SW conventional suction system: 0.1 gph line integrity test is RD RD RD RD performed every three nears. 40 CFR 280.40,280.41; T23 CCR 2643(d) Bakersfield Fire Department — Prevention Services Division, 2101 H Street, Bakersfield, CA. 93301 (661) 326 -3979 UNDERGROUND STORAGE TANK COMPLIANCE INSPECTIONi REPORT Facility Name: Date: 053 SW conventional suction system: inspections conducted for presence of air in the pipeline. Daily monitoring records are , kept. T23 CCR 2643(d) 054 SW gravity flow piping: biennial 0.1 gph integrity test or overfill tank integrity test is conducted within allowable time frames. T23 CCR 2643(g) O Safe Suction (SS) System 055 Piping meets the SS requirements. 40 CFR 280.49; T23 CCR 2636(a)(3) RD RD RD RD (A-D O LLD for Pressurized Piping 056 LLD's installed, annually tested and operational on SW pressurized piping. Pump shuts down when a leak occurs and RD RD RD RD El when the LLD fails or is disconnected. T23 CCR 2666 177157 LLD's installed, annually tested, and operational on SW emergency generator systems; LLD is connected to an AN alarm. 40 CFR 280.40(a)(2), 280.43(g)(9), (2), 280.44(a); T23 CCR 2666 Corrosion Protection 58 Metal Tanks and piping components have corrosion protection, RP RP RP RP or are isolated from the backfill. 40 CFR 280.20, 280.29 X59 Corrosion protection equipment turned on, functioning properly and provides continuous protection. 40 CFR 280.39(a),(b)(9); T23 CCR RP RP RP RP 2635 X60 Cathodic protection system is tested within 6 months of installation and then every 3 years. 40 CFR 280.39(a) & (b)(9); T23 CCR RP RP RP RP 2635 a 2 ;X*61 Impressed current systems checked every 60- calendar days RP RP RP RP and records are up-to-date. 40 CFR 280.39(c); T23 CCR 2635(a)(2) On -site Paperwork W2 Permit and conditions available on -site. Facility is operated 0 according to permit and conditions. HSC 25293,25299; T23 CCR 2792(i) X63 Monitoring and response plans are on -site and are the approved version. T23 CCR 2792(i); 2632 ;2634; 2649 A64 Site plan depicts current site conditions and has all required El elements. T23 CCR 2632(d) 65 All release detection records for monitoring method are available, up -to -date, and appropriate for leak detection RD RD RD RD El method. 40 CFR 280.49, 280.45 1966 All monitoring /testing records /documents are available for the required timeframe. (3 years, 6'/2 years, five years, life of tank) T23 CCR E] 2792 1967 Equipment maintenance records/logs available. T23 CCR 2792(b) El 1 068 Alarm logs /tapes available and appropriate follow -up actions 0 f,2�C 14 R15_a&18WiY occurred. T23 CCR 2792(b); 2632; 2634 J ! ❑69 Visual observation logs available, up -to -date, and appropriate - follow-up actions to problems occurred. T23 CCR 2792(b); 2642 - ;,70 Designated UST Operator monthly reports available and 0 complete. T23 CCR 2795 X71 Employee training records available and training appropriate and up -to -date. T23 CCR 2795 ,K72 Suspected or actual unauthorized releases are recorded and /or reported within allowed timeframes, including non- RD RD RD RD El passing test results. Leak and Spill Logs available. 40 CFR 280.50, T23 CCR, 2650, 2652 W3 Financial Responsibility Certificate and mechanisms (CFO Letter, etc.) on -site and up -to -date. HSC 25292.2, 25299.30- 25299.34; T23 Ll I I CCR 2711; T23 2808.9; 2809 - 2809.2 Bakersfield Fire Department — Prevention Services Division, 2101 H Street, Bakersfield, CA 93301 (661) 326 -3979 UNDERGROUND STORAGE TANK COMPLIANCE INSPECTION REPORT Facilitv Name: Date: On -Site Observation of Periodic Testing 074 Spill- bucket testing conducted appropriately and a passing test achieved. 075 Secondary Containment testing conducted appropriately and a passing test achieved. SOC AND RED TAG Item # Inspection Comments: Bakersfield Fire Department — Prevention Services Division, 2101 H Street, Bakersfield, CA 93301 (661) 326 -3979 �l a. This facility is in compliance with Release Detection (RD) requirements only. (No violations in boxes marked RD, but one or more in boxes marked RP.) ❑ b. This facility is in compliance with Release Prevention (RP) requirements only. (No violations in boxes marked RP, but one or more in boxes marked RD.) c. This facility is in compliance with BOTH Release Detection (RD) and Release Prevention (RP) requirements. (No violations in boxes marked RD or RP.) ❑ d. This facility is NOT in compliance with both Release Detection (RD) and Release Prevention (RP) requirements. (One or more violations marked in (broth) boxes RD ❑ and RP.) 4% �i4cY. � r .. '.9.. .K x ... •�xN A .. ...u"dkri.. ... . -.. .:wfm`v�`�`�w�.l?9 �+�'� .. a. � $a.^w+k�T3. >�.,.�ht vaP!^,1M 3�'.aw. G. f. 3c`};. n. s'`:.. �. i2:` A��'........::.trc.":.1....a..�. `'ii.:.S�'�tsss� �4 \ "k+"'�` ..�: id.5v >.�'kiSsrrr"y'hW'Fr'. �`Y.. A Red Tag was issued to this facility based on the results of this inspection. ❑ Red Tag # Reason for Red Tag (Choose one): 1. Violation that causes or threatens to cause a liquid release. CCR 2717(a)(1) ❑ 2. Violation that impairs the ability of an UST system to detect a leak: CCR 2717(x)(2) El 3. Chronic violation or committed by a recalcitrant violator. CCR 2717(a)(3) ❑ Item # Inspection Comments: Bakersfield Fire Department — Prevention Services Division, 2101 H Street, Bakersfield, CA 93301 (661) 326 -3979