Loading...
HomeMy WebLinkAboutINSPECTION REPORT 2015Underground Storage Tank Program DW Inspection Repo Permission to Inspect: BAKERSFIELD FIRE DEPARTMENT Prevention Services Division 2101 H Street Bakersfield, CA 93301 Phone: 661 - 326 -3979 Fax: 661 -852 -2171 Business Name: AT &T CORP - CAK010 -15- 021 - 003742 -AT &T Corp Date:12/4/2015 Address Name: 1520 20TH ST- CAD982000200 Inspector Name: Shane Gardner #8248557 Inspection Type: Routine Report: Final NVO = No Violation Observed OUT = Out of Compliance NA = Not Applicable UD = Undetermined COS = Corrected On Site RPT = Repeat Violation Violation Program Requirement d o SOC Comments No (0) 2 e� W z O z U p> File Review Facility Tank Information 2030021 Facility has a valid Permit Tank 1- 8000 -DW -DSO to Operate from the Tank 2- CUPA - 23 CCR 16 2712(1); ® ❑ ❑ ❑ ❑ ❑ None Tank 3- HSC 6.7 25284 Tank 4- 2010010 UST Operating Permit Application for Facility information and Tank information ® ❑ ❑ ❑ ❑ ❑ None submitted /maintained - 23 CCR 16 2711; HSC 6.7 25286(a 2010001 Current BOE number submitted to the CUPA ® ❑ ❑ ❑ ❑ ❑ None and /or CERS - HSC 6.7 25286(c) 2030011 UST compliance statement and /or Designated Operator ® ❑ ❑ ❑ ❑ n None current certification submitted - 23 CCR 16 2715(a), 2715(b 2030046 A complete and accurate response plan has been submitted, approved and ® ❑ ❑ ❑ ❑ None maintained - 23 CCR 16 2632, 2634(e), 2641(h), 2712(1) 2030041 A complete and accurate plot plan has been submitted, approved and ® ❑ ❑ ❑ ❑ ❑ Minor maintained - 23 CCR 16 2632(d)(1)(C, 2711 a (8) 2010006 Owner /Operator has not made false statements or representation on any ❑ ❑ ❑ ❑ ❑ None required document - HSC 6.7 25299 2010003 Owner /Operator has a DO and /or informed the CUPA of any change (s) ® ❑ ❑ ❑ ❑ [� None within 30 days - 23 CCR 16 2715(a) Violation Program Requirement °� o SOC Comments _NO _ ,_ Q 0 O n~. CD's __ ..............._.._.__....__. __,._ _ _ _. ,. z O z M 0 W ) ], Testing 2030002 Owner /Operator has tested and certified leak ® ❑ ❑ ❑ ❑ ❑ None detection equipment annual) - 23 CCR 16 2638 2030048 Secondary containment testing conducted every 36 months in accordance ® ❑ ❑ ❑ ❑ ❑ None with requirements - 23 CCR 16 2637 2030055 Spill buckets have been tested annually as ® ❑ ❑ ❑ ❑ ❑ None required - HSC 6.7 25284.2 2010009 Secondary containment test results submitted to the CUPA within 30 days ❑ ❑ ❑ ❑ ❑ None after the test - 23 CCR 16 2637(e) 2030064 CUPA was poperly notified within the prescribed number of ® ❑ ❑ ❑ ❑ ❑ None hours prior to testing - 23 CCR 16 2637(0, 2638(e), 2643(8), 2644.1(a)(4) Install /Repair 2060009 Permits obtained to install, replace, repair, or ® ❑ ❑ ❑ ❑ ❑ None modify part of the UST s stem - 23 CCR 16 2712 UST System Observation General Monitoring 2030003 Leak detection system maintains continuous RD monitoring that activates ® ❑ ❑ ❑ ❑ ❑ None ❑ an audible and visual Yes alarm - 23 CCR 16 2632, 2634, 2636, 2666 2030016 The annular space of the tank, piping and sumps are continuously RD monitored and activates ® ❑ ❑ ❑ ❑ ❑ None ❑ the alarm - 23 CCR 16 Yes 2631(g), 2632(c)(2)(A) &(B), 2633(c , 2636 2030017 Product piping outside the UDC is fail -safe and shuts down the pump or ® ❑ ❑ ❑ ❑ ❑ None restricts flow - 23 CCR 16 2636(/, (5) 2030018 Turbine sump monitor activates an audible and RD visual alarm or stops the ® ❑ ❑ ❑ ❑ ❑ None ❑ flow of at the dispenser - Yes 23 CCR 16 2636(0(1) Underground Storage Tank Program - DW Inspection Report v 2.0 Violation Program Requirement °, o SOC Comments No O (L d z NO z 0 o> 2030019 Monitoring system in the UDCs activates an audible and visual alarm ® ❑ ❑ ❑ ❑ ❑ None or stops the flow at the UDC -23 CCR 16 2636(0_(l) 2030043 Leak detection equipment RD properly programmed or properly operated - 23 ® ❑ ❑ ❑ ❑ ❑ None ❑ CCR 16 2632, 2634, 2636, Yes 2666 2060005 System constructed with a monitoring system capable of detecting entry ® ❑ ❑ ❑ ❑ ❑ None into secondary containment - HSC 6.7 25291(b) 2060014 Correct leak detection equipment installed for RD . the type of system ® ❑ ❑ ❑ ❑ ❑ None ❑ present - 23 CCR 16 2638; Yes HSC 6.7 25290.1, 25290.2, 25291 2060015 Sensor located in the RD proper position /location - ® ❑ ❑ ❑ ❑ ❑ None ❑ 23 CCR 16 2630(d), 2641(a) Yes 2030062 Facility is in compliance RD with not tampering with or disabling leak detection ® ❑ ❑ ❑ ❑ ❑ None ❑ devices or alarms - HSC Yes 6.7 25299(a)(9) .2060022 System constructed with a monitoring system capable of detecting entry Z ❑ ❑ ❑ ❑ ❑ None into secondary containment - HSC 6.7 25290.2(d) 2030034 Tag /sticker on affixed monitoring equipment being certified, repaired, ® ❑ ❑ ❑ ❑ ❑ None or replaced - 23 CCR 16 2638(1) VPH Monitoring VPH 2030065 Interstitial monitoring of RD the annular spaces of the UST is properly ® ❑ ❑ ❑ ❑ ❑ None ❑ maintained - HSC 6.7 Yes 25290.1(e 2060023 System constructed with a monitoring system capable of detecting entry into secondary ® ❑ ❑ ❑ ❑ ❑ None containment - HSC 6.7 25290.1(d) Underground Storage Tank Program - DW Inspection Report v 2.0 Violation Program Requirement 00 .0 SOC Comments No Oj D C1 0 M 0 'W C %. O 0 CO Z 0 Z U 05 C) Line Leak Detector 2060012 Line leak detector installed on pressurized RD piping system - HSC 6.7 El ❑ F] n ❑ None ❑ 25290.1(h), 25290 . 2(g), Yes 252910, 25292(e), 2636(1) (2) 2030026 Line leak detectors detect a 3 gph leak and/or RD audible and visual alarm None ❑ function properly - 23 Yes CCR 16 26360(6), 2666(c) 2030027 Turbine shuts down when a leak is detected or RD when line leak detector is ❑ ❑ Z ❑ ❑ ❑ None ❑ disconnected - 23 CCR 16 Yes 2666(c) 2030025 Pressurized piping able to detect a 3.0 gph leak RD within an hour, and E ❑ ❑ 1:1 1:1 ❑ None F-1 restricts the flow or Yes alarms - 23 CCR 16 2636(0(2) Secondary Containment 2060010 UST storing a hazardous RD substance has secondary F-1 None ❑ containment - HSC 6.7 Yes 25292 Underground Storage Tank Program - DW Inspection Report v 2.0 Violation Program Requirement 4- 0 9.2 SOC Comments No O 0 Co 0 � 0. - 14-) % 0 Z 0 Z 0 W > 0.- 2030008 UDC, sumps, and/or other secondary containment in good ❑ ❑ ❑ ❑ ❑ None condition and/or are free of debris/liquid - HSC 6.7 25290.1, 25290.2, 25291 2030040 Secondarily contained RD piping maintained to allow Z ❑ E] ❑ ❑ ❑ None ❑ liquid to drain into sump - Yes 23 CCR 16 2630(d), 2641(a) 2060006 Secondary containment piping slopes back to the 0 El F-1 ❑ F-1 ❑ None collection sump - 23 CCR 16 263(c) 2030047 Secondary containment maintained tight and has been confirmed by testing Z ❑ ❑ ❑ ❑ ❑ None - 23 CCR 16 2662; HSC 6.7 25290.1(c)(2), 25290.2(c)(2), 25291(a), 25292(e) 2030060 Entry fittings in secondary containment for UST system maintained Z ❑ ❑ ❑ None tight/sealed - 23 CCR 16 2630, 2635(d), 2636(c), 2666 2060020 Spill bucket is installed RP and has a functional drain valve or other means to ❑ ❑ ❑ ❑ None ❑ remove liquid - 23 CCR 16 Yes 2635 2665 2030054 Spill bucket maintained in RP good condition and free of E Ej ❑ ❑ ❑ ❑ None ❑ debris and/or liquid - 23 Yes CCR 16 2635(b), 2715(c)(2) 2060019 Spill bucket to has a minimum capacity of five E El F-1 ❑ ❑ ❑ None gallons - 23 CCR 16 2635(b), 2665 Overfill 2030035 UST system is operated RP to prevent unauthorized release, including spills None ❑ and overfills - HSC 6.7 Yes 25292.1 (a) 2030036 Overfill prevention system RP has not been overridden and meets overfill E ❑ ❑ ❑ ❑ r-1 None ❑ requirements - 23 CCR 16 Yes 2635(b)(2), 2665 Underground Storage Tank Program - DW Inspection Report v 2.0 Violation Program Requirement 0 0 0 SOC Comments No co 0 (L = ('D (u 075 z 0 z M M 0 w 05 On Site Records Certifications 2030023 Required designated operators or contractors maintain a proper and ❑ ❑ ❑ ❑ F-1 None current ICC certification - 23 CCR 16 2715 2030024 Service technician, installer, and/ or employee maintain a ❑ ❑ ❑ ❑ ❑ None proper license - 23 CCR 162715 2030031 Employee or contractor obtained and maintained proper manufacturer None certification - 23 CCR 16 2715 2010007 Submit/maintain current Certificate of Financial Responsibility /mechanism of financial assurance - E El ❑ ❑ ❑ F-1 None 23 CCR 16 2711; 23 CCR 18 2808.1, 2809-2809.2; HSC 6.7 25292.2; HSC 6.75 25299.30-25299.34 Designated Operator 2010004 Copies of DO inspections for last 12 months and list of trained employees E ❑ ❑ 1:1 ❑ ❑ None maintained - 23 CCR 16 2715 2030013 Designated operator properly conducted the monthly inspection and E ❑ ❑ ❑ ❑ ❑ None the reports are complete - 23 CCR 16 2715 2030010 DO notified operator of any condition observed during the monthly E ❑ ❑ ❑ F-1 r-1 None inspection that may require action - 23 CCR 16 2715(d) 2030012 DO employee training performed, current for at least one employee on E ❑ ❑ F-1 ❑ r-1 None site, and a log kept - 23 CCR 16 2715(c)(6), 2715(1) Underground Storage Tank Program - DW Inspection Report v 2.0 Violation Program Requirement 4- 0 .2 v SOC Comments No 0 > 1— M :t a C* 0 a. 2 (a 075 Z 0 Z M 0 W > Logs 2030001 Leak detection alarm logs, maintenance and RD records of appropriate ❑ ❑ ❑ ❑ ❑ None ❑ follow-up actions Yes maintained - 23 CCR 16 2632, 2634, 2712(b) Maintenance/Tests 2010008 Monitoring, maintenance, repairs, linings, and RD upgrade records ED ❑ ❑ [__j ❑ ❑ None ❑ maintained for the proper Yes time period - 23 CCR 16 2712(b) Documentation 2030033 Failure to maintain on site an approved monitoring ❑ None plan - 23 CCR 16 2632, 2634, 2711, 2712(1) 2030037 Written agreement between the tank owner and tank operator to monitor the tank system S ❑ ❑ ❑ ❑ ❑ None is maintained - 23 CCR 16 2620(b); HSC 6.7 25284(a)(3) 2030061 Suspected or actual RD unauthorized release reported in appropriate ❑ ❑ S ❑ ❑ ❑ None ❑ time frame - HSC 6.7 Yes 29294,29295 General Operating Requirements Permit Condition/Approval 2030039 Compliance with all operating permit None conditions - 23 CCR 16 2712, HSC 6.7 25299 2030059 UST system maintained in accordance with exclusion/exemption ❑ ❑ ❑ 1:1 ❑ None status - HSC 6.7 25281.6, 25283.5 2030014 Owner/Operator received approval and has implemented a training El ❑ 0 ❑ None program at an unstaffed facility - 23 CCR 16 2715(f)(2) 2030015 Facility exhibited that the method used to monitor the tank meets the monitoring methods in ❑ ❑ ❑ ❑ ❑ None 2643(f - 23 CCR 16 2643 Underground Storage Tank Program - DW Inspection Report v 2.0 Violation Program Requirement ° o SOC Comments No a0.' 0 z O z D U o> Red Tag 2030045 Red Tag information is legible and has not been ❑ ❑ ® ❑ ❑ ❑ None tampered with - 23 CCR 16 2717.1(g) 2030044 Facility did not allow for deposit of petroleum into a UST that has a red tag ❑ ❑ ® ❑ ❑ ❑ None affixed to the fi II - 23 CCR 16 2717.1( Install /Repair 2060024 UST system is made of or lined with materials that are compatible with the ® ❑ ❑ ❑ ❑ ❑ None substance stored - 23 CCR 16 2631.1 2060021 Striker plate installed and positioned correctly - 23 ® ❑ ❑ ❑ ❑ ❑ None CCR 16 2631(c), 2662(d) ® There were no violations noted for this inspection. ❑This report shall serve as a "NOTICE TO COMPLY" for Minor Violations, and a "NOTICE OF VIOLATION" for Major violations. You are, hereby, ordered to correct the above noted violations within 30 days, or according to correction summaries provided. Formal enforcement and /or penalty assessment may be initiated for any violations noted, and for those not corrected in a timely manner. (NOTE: If this is a preliminary report, a final report will follow.) ,, Inspectors Signature: '' f�� `� `'Z- Date: %2-- c(✓l Inspector: Enter # of Violations: RD:. /--) RP: Check one box for facility Significant Operational Status (SOC) to be reported to SWRCB and US EPA: OC with both Release Detection and Release Detection (Facility has no Release Prevention and no Release revention Violations) ❑ Not in SOC (Facility has both Release Prevention and Release Detection Violations) ❑SOC with Release Detection only (Facility has no Release Detection violations but one or more Release Prevention violations) ❑ SOC with Release Prevention only (Facility has no Release Prevention violations but one or more Release Detection violations) Underground Storage Tank Program - DW Inspection Report v 2.0 FACILITY NAME / CER.S INSPECTION DATE /' V= Violation; 1,11 Minor INSPECTION TIME ADDRESS. PHONE NO. NO OF EMPLOYEES APPROPRIATE PERMIT ON HAND (BMC: 15.65.080) 3010001 FACILITY CONTACT BUSINESS ID NUMBER i2 11-1t�l BUSINESS PLAN, CONTACT INFORMATION ACCURATE (CCR: 2729..1) Consen oInspect Nam, e/ itle l` VISIBLE ADDRESS (CFC: 505.1, BMC: 15.527020) = omp lance (; V OPERATION CER.S V= Violation; 1,11 Minor Violation COMMENT. APPROPRIATE PERMIT ON HAND (BMC: 15.65.080) 3010001 BUSINESS PLAN, CONTACT INFORMATION ACCURATE (CCR: 2729..1) 1010008 l` VISIBLE ADDRESS (CFC: 505.1, BMC: 15.527020) CORRECT OCCUPANCY (CBC: 401) VERIFICATION OF INVENTORY MATERIALS (CCR: 2729.3) . 1010004 VERIFICATION OF QUANTITIES (CCR: 2729.4) 1010006 VERIFICATION OF LOCATION (CCR: 2729.2) >4., - t PROPER SEGREGATION OF MATERIAL (CFC: 2704.1) VERIFICATION OF SDS AVAILABILITY (CCR: 2729.2(3)(b)) VERIFICATION OF.HAZ MAT TRAINING (CCR: 2732) 1020002 :. VERIFICATION OF ABATEMENT SUPPLIES & PROCEDURES (CCR: 2731(c)) EMERGENCY PROCEDURES ADEQUATE (CCR: 2.731) 1010010 CONTAINERS oPROPERLY LABELED (CCR: 66262.34(1); CFC: 2703.5) 3030007 L ' HOUSEKEEPING (CFC: 304.1) FIRE PROTECTION (CFC: 903 & 906) . 3030032 r SITE.DIAGRAM ADEQUATE & ON HAND (CCR: 2729:2) 1010005 ANY HAZARDOUS WASTE ON SITE? DYES ❑ NO Signature of Explain: + Inspector. POST INSPECTION INSTRU.CTIONS:. • Correct the violation(s) noted. above by • Within 5 days of correcting all of the violations, sign and return a copy of this page to: Signature (that all violations have been corrected as noted) Bakersfield Fire Dept., Prevention Services, 2101 H Street, California 93301 Date Wh;tP R„s7nf— Conv Yellow – Station CoUv Pink — Prevention Services FD2155: (Rev 8//14) HAZARDOUS WASTE BAKERSFIELD FIRE.DEPARTMENT UNIFIED PROGRAM CONSOLIDATED FORMS B E R s F 1 Prevention Services FIRE . 2101 Street SMALL QUANTITY HAZARDOUS ARr T Bakersfield, 93301 WASTE GENERATOR I SPECTIO Phone: 661' -326 -3979 •Fax: 661 7852 -2171 Facility Name: .. fr t' { r,�-1. Date: -fir'° I Y Site Address:. a Time In: Time Out: Owner /Operator::: ° % ", ,;' Phone: EPA ID.# A i / �)260 t1 C,C Type of lnspection 0 Routine 0 Re- inspection/Follow -up C'bmbined Routine Ins , ectio 0 o' ton Complaint 0 Focused 0 Other � Q CONSENT TO INSPECT GRANTED BY (Name / Title): �✓ Inspection may involve obtaining photographs, review and copying of records, and determination of compliance with hazardous waste handling requirements. C V HAZARDOUS WASTE REQUIREMENT CERS N/A Violation # COMMENTS Recordkee ing/documentation . Generator -has an EPA ID number [HSC 25143:131 3010002 Hazardous wast�etermination made for all wastes 0 Analysis ,DGenerator Knowledge [CCR 66262.401 3030005 `. Contingency plan information posted near phone . [CCR 66262.34(d)(2)] 3010022 Facility personnel demonstrate training /awareness [CCR 66262.34(d)(2)]. 3020001 . Manifests /Consolidated Manifest receipts complete [CCR 66262.23(x)] 3010008 Blue copy(s) of manifest hailed to DTSC [CCR 66262.23(a)(4)] 3010011 Bills of Lading/receipts available [CCR 66262.40(a)] l 3010010 LDRs available and complete [CCR.66268.7(a)] 3030006 Onsiterecycling reported using UPCF [HSC 25143.101 3030001 Container /tank.management Containers are in good condition [CCR 66262.34(d)(2)] 3030013 Containers are closed except when. adding /removing [CCR66262.34(d)(2)] 3030017 Satellite containers at or near point of generation [CCR 66262.34(e)(1)(A)] Empty containers are empty [CCR 66262.34(f)] ' ' 3030007 Containers inspected weekly [CCR 66262.34(d)(2)] 3030019 Tanks ins ected Bail. [CCR. 66262.34(d)(2), 40CFR 265.2011 '; 3030027 One container per waste stream at satellite area [CCR 66262.34(d)(2)] - ' 3030022 Exclude recyclable materials stored in accordance with local ordinance/hazardous materials codes [HSC 25143.10] 3010016 Accumulation Time Limits ; Waste is accumulated not more than 90/CW/,170 [CCR 66262.34(d)] 3030010 Empty containers managed within one year [CCR 66262.34(d)] 3030010 Universal waste accumulated less than one year [CCR 66273:15(a)] 3030011 Used oil filters offsite within 180 (1 year <1 ton) . [CCR 66266.130(c)(4)] 3030004 Pb -acid batteries offsite within 180 (l yr. < 1 ton) . [CCR66266.81(a)(3)] 3030002 Labeling/Marking .�` Containers are properly labeled [66262.34(f)] 3030007 Excluded recyclable materials marked properly [HSC 25143.9(a)] 3050005 Universal waste container properly labeled (CCR 66273.341 3030008 Used oil filters marked "drained used oil filters" [CCR 66266.1301 1 3030004 Date written on spent lead -acid batteries [CCR 66266.8.1(a)(6)(B)] 1 3030003 "Used Oil" marked on all used oil tanks /containers [CCR 66279.21(b)] 3030007 7' Tank marked with "haz waste" ;contents, start date [66262.34(f)] 3030007 Treatment, Trans ort and Disposal /Other Have ermit/authorization to do treatment [HSC 25136.21 1 3040003 Waste sent with authorized transport (gen. eligible) .. [CCR 66263.41] 3050001 Waste disposed of to authorized point/ arty [HSC 25189.5(a)] 3050002 Failed to properly handle appliance wastes [HSC 25212(a)] Fire Protection [66262:34(d)(2)] 3030032 Print and sign in t 'box for recet of this report. Signature does not imply agreement with findings only receipt of report. L INSPECTOR; POST INSPECTION INSTRUCTIONS: • Correct the violation(s) noted above by • Within 5 days of correcting all of the violations, sign and return a copy of this page to: Bakersfield Fire Dept., Prevention Services, 2101 H St. Bakersfield, CA 93301 White = Business Copy Yellow— Station Copy FD2171 (Rev 9/14) Pink - Prevention Services Copy