Loading...
HomeMy WebLinkAbout1.2-6824 Ph 2LEGEND: ABBREVIATIONS CL INV SD MH CB JB SMH SCO SDMH EXIST ELEV R/W T. M. 363 22 s O CENTERLINE INVERT STORM DRAIN MANHOLE CATCH BASIN JUNCTION BOX SEWER MANHOLE SEWER CLEANOUT STORM DRAIN MANHOLE EXISTING ELEVATION RIGHT OF WAY TOP OF MANHOLE /TOP OF CLEANOUT ELEVATION CONSTRUCT SEWER PER CITY STANDARDS CONSTRUCT SEWER MANHOLE TYPE "A" PER C.O.B. STD. S -7. CONSTRUCT SEWER CLEANOUT PER C.O.B. STD. S -20. CONSTRUCT STORM DRAIN PER CITY STANDARDS 0 CONSTRUCT STORM DRAIN MANHOLE TYPE "A" PER C.O.B. STD. S -7. 15� CONSTRUCT CATCH BASIN TYPE "A" PER C.O.B. STD. S -12. SUMMARY OF IMPROVEMENTS SEWER IMPROVEMENTS TOTAL 6" SEWER LINE 224 LF 8" SEWER LINE 2111 LF 4" LATERALS 2205 LF STANDARD MANHOLE 6 EA SEWER CLEAN OUT 3 EA STORM DRAIN IMPROVEMENTS TOTAL 18" STORM DRAIN LINE 510 LF 24" STORM DRAIN LINE 185 LF STORM DRAIN MANHOLES 3 EA CATCH BASINS 2 EA MULTIPLE UTILITY TRENCH (L SEWER MAIN ' R 5' 4 R TYP. " „ 4' 4FACE P AN S 5' WATERLINE Y E CURB TYP Y mR LEOTERAL FINISHED STREET GRADE 3 36" TYP. 0" 7' MAX . ° YP. O 7' MAX. 1 � MIN 1% MIN. 4- LATERAL (TYP) \ _ 4" LATERAL (TYP) � \ ON DEEP SEWER, SLOPE LATERALS-/ ' ' SET LATERAL PROVIDING PROPER TO LOT LINE SO THAT THE END OF CLEARANCE UNDER WATERLINE AND LATERAL IS WITHIN REQUIRED UTILITY TRENCHES TOLERANCE. DETAIL TYPICAL SEWER LATERAL INSTALLATION * FOR SHALLOW INSTALLATION OF SEWER LATERALS FROM SHALLOW SEWER MAINS, THE SEWER LATERALS MUST CROSS OVER THE WATER OR UTILITY TRENCH. THESE INSTALLATIONS MUST RECEIVE SPECIAL TREATMENT FOR LATERALS WHEN CROSSING OVER THE WATERMAN. A SEWER LATERAL CROSSING ABOVE A WATER MAIN SHALL BE CONSTRUCTED OF A CONTINUOUS 20' SECTION OF CLASS 200 (DR 14 PER AWWA C900) PLASTIC PIPE OR EQUIVALENT, CENTERED ON THE PIPE BEING CROSSED. VICINITY MAP N. T. S. INDEX OF SHEETS SHEET TITLE 1. COVER SHEET 2. NOTES 3. FORT SANDERS AVENUE 4. ESTACADA AVENUE 5. COOPER LAKE AVENUE & VOYAGEURS DRIVE 42 43 40 41 44 4tf 4e 47 48 /e s0 64 — LI— — — 4 - �o1__I�._JJ _ _ _ s _ _ as �J° I —ij 1 I f2B 27 ] � N °° � 31 5 4 0 PHASE f j(_', J ee C"ER LAKE AVENUE &-- — I 12 I ' I ;dt_ _ I I I i I ! , _► , C� � �10 II 11 12 13 14 I 16 1s 17 to 19 i �e I I LP �� EL_LI1 =J I I J r Ta 7 a l 754 I 3 g I CITY OF BAKERSFIELD KERN COUNTY CALIFORNIA STORM DRAIN AND SEWER PLANS FOR V E 3 T I N G T E N T A T I V E 0 T R A C T M A P 6 g g Z J NOTE: w KEY MAP ALL PHASES ARE OWNED BY THE SAME OWNER. ALL PHASES TO BE CONSTRUCTED SIMULTANEOUS_ • SCALE: 1" = 200' VESTING TENTATIVE TRACT NO. 6824 PHASE 2 NOTE: 1. PRIOR TO THE START OF ANY PHASE OF CONSTRUCTION, THE CITY CONSTRUCTION INSPECTION DEPARTMENT SHALL BE GIVEN 24 HOURS NOTICE. TELEPHONE 326 -3049 2. ALL MATERIALS SUPPLIED FOR THIS PROJECT WILL REQUIRE A CERTIFICATE OF COMPLIANCE STATING THAT THE REQUIREMENTS & STANDARDS SET FORTH BY THE CITY OF BAKERSFIELD HAVE BEEN MET. 3. NO CITY INSPECTIONS WILL BE GIVEN FOR THE WORK IN THIS AREA UN11L STREET PERMIT WITH APPROPRIATE SECURITY AND INSURANCE HAS BEEN OBTAINED. LNVINLLN'S STATEMENT THESE PLANS AND SPECIFICATIONS WERE PREPARED BY ME OR UNDER MY DIRECTION AND TO THE BEST OF MY KNOWLEDGE AND BELIEF COMPLY WITH CITY OF BAKERSFIELD ORDINANCES, STANDARDS, AND DESIGN CRITERIA AND INCLUDE ALL IMPROVEMENT REQUIREMENTS OF THE ADVISORY AGENCY OR OTHER REVIEW BOARD. I AM RESPONSIBLE FOR ALL CALCULATIONS AND DRAWINGS ON THESE PLANS AND ANY ERRORS, OMISSIO S, OR VIOLATIONS OF THOSE INANCES, STANDARDS AND DE IG�J CRITERIA SHALL BE COR , TED DURING CONSTRUCTION. / ! I VV �'i APPROVED BY: ROGER A. McINTOSH R.C.E. 33322 EXP. 6 -30 -16 1'13-15 DATE IN ACCORDANCE WITH THE CONDITIONS OF THE VESTING TENTATIVE MAP, THE IMPROVEMENT PLANS HAVE BEEN REVIEWED BY THE CITY OF BAKERSFIELD PUBLIC WORKS DEPARTMENT. ALL IMPROVEMENTS INDICATED AS "PRIVATE" HEREIN ARE PRIVATE AND ARE TO BE PRIVATELY MAINTAINED. APPROVED BY: NICOLAS FIDLER, PUBLIC WORKS DIRECTOR R.C.E. NO. 61069 EXP. 12 -31 -16 1_0 is DATE REVIEWED BY: ASSISTANT PUBLIC WORKS DIRECTOR DIG ALERT Cali: TOLL FREE 1 - 800 - 227 -2600 AT LEAST TWO DAYS BEFORE YOU DIG UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA BASIS OF BEARINGS: THE BEARING OF N. 89'06'48" W. SHOWN FOR THE NORTH LINE OF THE NORTHEAST QUARTER OF SECTION 30, T. 30S., R. 27E. ON K.C.S. FILED MAP NO. 7 -1 BK. 6, PG. 26 IN THE OFFICE OF THE KERN COUNTY SURVEYOR WAS USED AS THE BASIS OF BEARINGS SHOWN HEREON. BENCHMARK: TOP OF CONCRETE MONUMENT IN LAMPHOLE AT THE INTERSECTION OF PANAMA LANE AND MOUNTAIN VISTA DRIVE. ELEVATION = 350.20' (USGS DATUM) LEGAL DESCRIPTION: LOTS 15 AND 16 OF SECTION 30, TOWNSHIP 30 SOUTH, RANGE 27 EAST, M.D.M., CITY OF BAKERSFIELD, COUNTY OF KERN, STATE OF CALIFORNIA, ACCORDING TO THE SALES MAP OF LANDS OF THE KERN COUNTY LAND COMPANY FILED JANUARY 22, 1892. CITY RECORDS NO: 0) OD V♦ W WHITE LN 0 0 v ° 0 < z WHITE LN r O Z 00 o D 4� U Q _ O z Z LL_ I m D ° o LLj U _ a W 00 CL AR m ~ W;D- LWU PANAMA LN = W N O (n v CI) J c co N c1f m o Ld m z z Y < 9 W Y U F cn O Z t Z O r � O m N a W ® ° PROJECT SITE 3: Q m ; m 0 w J 0 TAFT HWY o ° 9'ORTS MLLAGE VICINITY MAP N. T. S. INDEX OF SHEETS SHEET TITLE 1. COVER SHEET 2. NOTES 3. FORT SANDERS AVENUE 4. ESTACADA AVENUE 5. COOPER LAKE AVENUE & VOYAGEURS DRIVE 42 43 40 41 44 4tf 4e 47 48 /e s0 64 — LI— — — 4 - �o1__I�._JJ _ _ _ s _ _ as �J° I —ij 1 I f2B 27 ] � N °° � 31 5 4 0 PHASE f j(_', J ee C"ER LAKE AVENUE &-- — I 12 I ' I ;dt_ _ I I I i I ! , _► , C� � �10 II 11 12 13 14 I 16 1s 17 to 19 i �e I I LP �� EL_LI1 =J I I J r Ta 7 a l 754 I 3 g I CITY OF BAKERSFIELD KERN COUNTY CALIFORNIA STORM DRAIN AND SEWER PLANS FOR V E 3 T I N G T E N T A T I V E 0 T R A C T M A P 6 g g Z J NOTE: w KEY MAP ALL PHASES ARE OWNED BY THE SAME OWNER. ALL PHASES TO BE CONSTRUCTED SIMULTANEOUS_ • SCALE: 1" = 200' VESTING TENTATIVE TRACT NO. 6824 PHASE 2 NOTE: 1. PRIOR TO THE START OF ANY PHASE OF CONSTRUCTION, THE CITY CONSTRUCTION INSPECTION DEPARTMENT SHALL BE GIVEN 24 HOURS NOTICE. TELEPHONE 326 -3049 2. ALL MATERIALS SUPPLIED FOR THIS PROJECT WILL REQUIRE A CERTIFICATE OF COMPLIANCE STATING THAT THE REQUIREMENTS & STANDARDS SET FORTH BY THE CITY OF BAKERSFIELD HAVE BEEN MET. 3. NO CITY INSPECTIONS WILL BE GIVEN FOR THE WORK IN THIS AREA UN11L STREET PERMIT WITH APPROPRIATE SECURITY AND INSURANCE HAS BEEN OBTAINED. LNVINLLN'S STATEMENT THESE PLANS AND SPECIFICATIONS WERE PREPARED BY ME OR UNDER MY DIRECTION AND TO THE BEST OF MY KNOWLEDGE AND BELIEF COMPLY WITH CITY OF BAKERSFIELD ORDINANCES, STANDARDS, AND DESIGN CRITERIA AND INCLUDE ALL IMPROVEMENT REQUIREMENTS OF THE ADVISORY AGENCY OR OTHER REVIEW BOARD. I AM RESPONSIBLE FOR ALL CALCULATIONS AND DRAWINGS ON THESE PLANS AND ANY ERRORS, OMISSIO S, OR VIOLATIONS OF THOSE INANCES, STANDARDS AND DE IG�J CRITERIA SHALL BE COR , TED DURING CONSTRUCTION. / ! I VV �'i APPROVED BY: ROGER A. McINTOSH R.C.E. 33322 EXP. 6 -30 -16 1'13-15 DATE IN ACCORDANCE WITH THE CONDITIONS OF THE VESTING TENTATIVE MAP, THE IMPROVEMENT PLANS HAVE BEEN REVIEWED BY THE CITY OF BAKERSFIELD PUBLIC WORKS DEPARTMENT. ALL IMPROVEMENTS INDICATED AS "PRIVATE" HEREIN ARE PRIVATE AND ARE TO BE PRIVATELY MAINTAINED. APPROVED BY: NICOLAS FIDLER, PUBLIC WORKS DIRECTOR R.C.E. NO. 61069 EXP. 12 -31 -16 1_0 is DATE REVIEWED BY: ASSISTANT PUBLIC WORKS DIRECTOR DIG ALERT Cali: TOLL FREE 1 - 800 - 227 -2600 AT LEAST TWO DAYS BEFORE YOU DIG UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA BASIS OF BEARINGS: THE BEARING OF N. 89'06'48" W. SHOWN FOR THE NORTH LINE OF THE NORTHEAST QUARTER OF SECTION 30, T. 30S., R. 27E. ON K.C.S. FILED MAP NO. 7 -1 BK. 6, PG. 26 IN THE OFFICE OF THE KERN COUNTY SURVEYOR WAS USED AS THE BASIS OF BEARINGS SHOWN HEREON. BENCHMARK: TOP OF CONCRETE MONUMENT IN LAMPHOLE AT THE INTERSECTION OF PANAMA LANE AND MOUNTAIN VISTA DRIVE. ELEVATION = 350.20' (USGS DATUM) LEGAL DESCRIPTION: LOTS 15 AND 16 OF SECTION 30, TOWNSHIP 30 SOUTH, RANGE 27 EAST, M.D.M., CITY OF BAKERSFIELD, COUNTY OF KERN, STATE OF CALIFORNIA, ACCORDING TO THE SALES MAP OF LANDS OF THE KERN COUNTY LAND COMPANY FILED JANUARY 22, 1892. CITY RECORDS NO: 0) OD V♦ W 0 0 v F- 0) 0 < .o J r O Z 00 o 0 U Q _ O z Z LL_ I m < J ° o LLj U _ a W 00 CL 3: o -. m ~ W;D- LWU w = W N O (n v CI) J c co N c1f m Ld m z z Y < 9 W Y U F m O U t Z Y Ni LLj U MM J Q L ¢ v d p, �P F- OD V♦ W Z co v I co .o J IL J 0 ^ fi _ CV "WZ W � _ a CL ~ LWU w = W N cr CI) J c co �W W z z 0 d F 0 V 0 t Z Y � v < N a W °° 3: 8 W W m 0 w J 0 a OD W co W r I co .o IL 0 STANDARD NOTES 1. GENERAL CONTRACTOR WILL FURNISH ALL MATERIALS, TOOLS, LABOR, EQUIPMENT AND SUPERVISION NECESSARY TO COMPLETE INSTALLATION. UNDERGROUND SERVICE ALERT (USA) SHALL BE NOTIFIED AT LEAST 2 WORKING DAYS BEFORE CONSTRUCTION. TELEPHONE 1- 800 - 227 -2600. CONTRACTOR TO CALL FOR USA LOCATE AND POTHOLE ALL MARKED UTILITIES THAT CROSS OR ARE WITHIN 5' HORIZONTAL DISTANCE OF SEWER AND STORM DRAIN LINES. VERTICAL AND HORIZONTAL LOCATION SHALL BE ASCERTAINED BY THE CONTRACTOR AHEAD OF ANY EXCAVATIONS TO VERIFY THAT THE PROPOSED DESIGN DOES NOT CONFLICT WITH ANY UTILITIES. IN THE EVENT A CONFLICT EXISTS THE ENGINEER SHALL BE NOTIFIED IN ORDER TO REDESIGN THE ALIGNMENT. IF RELOCATION OF EXISTING UTIUTIES IS DEEMED NECESSARY THE CONTRACTOR SHALL BE COMPENSATED FOR INSTRUCTED RELOCATION. IF REDESIGN OF THE ALIGNMENT REQUIRES ADDITIONAL FITTINGS, PIPE OR EXCAVATION THE CONTRACTOR SHALL BE COMPENSATED FOR REVISION. IN THE EVENT A UTILITY IS DAMAGED THE CONTRACTOR SHALL BE WHOLLY RESPONSIBLE FOR ITS REPAIR. CONTRACTOR SHALL VERIFY LOCATIONS AND ELEVATIONS OF EXISTING SEWER LINES THAT THE NEW SYSTEM TIES INTO PRIOR TO TRENCHING. ANY DISCREPANCIES SHAD_ BE REPORTED TO THE ENGINEER SO THAT ANY NECESSARY ADJUSTMENTS MAY BE MADE. U11UTIES SHALL BE THOROUGHLY RESEARCHED AND LOCATED BY CONTRACTOR PRIOR TO TRENCHING. CROSSING UTILITIES SHALL BE DAYLIGHTED AND CHECKED FOR GRADE, BY CONTRACTOR PRIOR TO TRENCHING. ALL EXISTING IMPROVEMENTS, (CURB, GUTTER, SIDEWALK, CROSS GUTTER, FENCES, ETC.) THAT ARE REMOVED, DAMAGED OR UNDERCUT SHALL BE REPAIRED OR REPLACED AS DIRECTED BY THE CITY ENGINEER. ALL EXISTING PAVING AND SURFACING REMOVED, DAMAGED OR UNDERCUT SHALL BE REPLACED IN ACCORDANCE WITH THE CITY OF BAKERSFIELD STANDARD DRAWING ST -6, EXCEPT AS NOTED ON PANS. 2. STANDARD DETAILS THE FOLLOWING CITY OF BAKERSFIELD STANDARDS SHALL BE CONSIDERED PART OF THESE PLANS: S -6, S -7, S -8, S -9, S -10, S -11, S -12, S -20, S -21, S -22. 3. VCP INSTALLATION MATERIALS : THE PIPE AND FITTINGS SHALL BE EXTRA STRENGTH VITRIFIED CLAY CONFORMING TO CURRENT ASTM SPECIFICATION C -700 AND SHALL BE INSTALLED IN CONFORMANCE WITH THE PROVISIONS OF SECTION 71 OF THE STANDARD SPECIFICATIONS OF THE STATE OF CALIFORNIA, DEPARTMENT OF TRANSPORTATION, CURRENT EDITION AND THE CURRENT ASTM SPECIFICATIONS C -12. JOINTS : THE PIPE AND FITTINGS SHALL HAVE A SOCKET END AND A SPIGOT END WITH COMPRESSION JOINTS CONFORMING WITH THE CURRENT ASTM SPECIFICATION C -425. THE PIPE AND FITTINGS FOR 6 ", 8 ", 10 ", AND 12" SANITARY SEWER MAINS MAY BE PLAIN -END WITH COMPRESSION COUPLINGS CONFORMING WITH THE CURRENT ASTM SPECIFICATION C -425. EXCEPTING THAT A STAINLESS STEEL SHEAR RING AS MANUFACTURED BY MISSION CLAY PRODUCTS CORPORATION FOR THEIR "MAINUNE" BANDSEAL COMPRESSION COUPLING, OR APPROVED EQUAL, SHALL BE REQUIRED. THE PIPE AND FITTINGS FOR PRIVATE SANITARY SEWER HOUSE OR BUILDING LATERALS MAY BE PLAIN -END WITH COMPRESSION COUPLINGS CONFORMING WITH THE CURRENT ASTM SPECIFICATION C -425. (STAINLESS STEEL SHEAR RINGS ARE NOT REQUIRED) 4. ABS PIPE INSTALLATION MATERIALS : PIPE AND FITTINGS SHALL MEET THE REQUIREMENTS OF THE CURRENT ASTM SPECIFICATIONS D -2680 AND D -2751. PIPE AND FITTINGS SHALL BE HOMOGENEOUS THROUGH OUT AND FREE FROM CRACKS, HOLES, FOREIGN INCLUSIONS OR OTHER INJURIOUS DEFECTS. FITTINGS SHALL BE INJECTION MOLDED AND SHALL BE INSTALLED IN UNE ON NEW PIPELINES; CUT -IN FITTINGS ARE NOT PERMITTED. JOINTS : USE ONLY SOLVENT WELDED JOINTS. THE ASSEMBLY OF JOINTS SHALL BE IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. WHERE ABS PIPE CONNECTS TO VCP, USE COUPLINGS APPROVED BY THE CITY OF BAKERSFIELD. INSTALLATION : PIPE AND FITTINGS SHALL BE INSTALLED IN ACCORDANCE WITH THE CURRENT ASTM SPECIFICATION D -2321. ONLY CLASS I, II, AND III EMBEDMENT MATERIALS WILL BE CONSIDERED SUITABLE. 5. PVC PIPE INSTALLATION MATERIALS : PIPE AND FITTINGS SHALL MEET THE REQUIREMENTS OF THE CURRENT ASTM SPECIFICATION D -3034 FOR SDR35. PIPE AND FITTINGS SHALL BE HOMOGENEOUS THROUGHOUT AND FREE FROM CRACKS, HOLES, FOREIGN INCLUSIONS OR OTHER INJURIOUS DEFECTS. FITTINGS SHALL BE INJECTION MOLDED AND SHALL BE INSTALLED IN UNE ON NEW PIPELINES; CUT -IN FITTINGS ARE NOT PERMITTED. JOINTS : USE ONLY ELASTOMERIC GASKET JOINTS. THE ASSEMBLY OF JOINTS SHALL BE IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS WHERE PVC PIPE CONNECTS TO VCP PIPE, USE COUPLINGS APPROVED BY THE CITY OF BAKERSFIELD. INSTALLATION : PIPE AND FITTINGS SHALL BE INSTALLED IN ACCORDANCE WITH THE CURRENT ASTM SPECIFICATION D -2321. ONLY CLASS I, It, AND III EMBEDMENT MATERIALS WILL BE CONSIDERED SUITABLE. 6. REINFORCED CONCRETE PIPE WITH PVC UNING. REINFORCED CONCRETE PIPE WITH PVC LINING SHALL MEET THE FOLLOWING REQUIREMENTS: 1.A. MATERIALS. REINFORCED CONCRETE PIPE (RCP) SHALL BE EITHER CLASS IV OR CLASS V WITH WALLS "B" OR V. RCP SHALL MEET ASTM C 76 FOR STRENGTH, ASTM C 361 OR AWWA C302 EXCEPT TEST PRESSURE SHALL BE 5 PSI FOR RUBBER GASKETS, AND LINER TESTS IN ACCORDANCE WITH THE FOLLOWING PARAGRAPHS. PIPE SHALL BE WET CAST, VIBRATED AND STEAM OR WATER CURED. JOINTS SHALL BE BELL AND SPIGOT DESIGN WITH A CONTAINED 0 -RING GASKET. PVC LINER SHALL BE CAST INTO THE WALL OF THE RCP AND SHALL COVER 360' OF THE PIPE. ALL WORK FOR AND IN CONNECTION WITH THE INSTALLATION OF THE LINING IN CONCRETE PIPE AND FIELD SEALING AND WELDING OF JOINTS SHALL BE DONE IN STRICT CONFORMITY WITH ALL APPLICABLE SPECIFICATIONS, INSTRUCTIONS AND RECOMMENDATIONS OF THE LINING MANUFACTURER. LINER SHALL MEET THE FOLLOWING REQUIREMENTS. 1.B. PHYSICAL PROPERTIES OF LINER. ALL PLASTIC LINER PLATE SHEETS, WELDING STRIPS AND OTHER ACCESSORY ITEMS, SHALL HAVE THE FOLLOWING PHYSICAL PROPERTIES WHEN TESTED AT 77-F t5 (25'C t3 ). PROPERTY INITIAL (a 6R. 1.0 TENSILE STRENGTH 2200 PSI MIN. 2100 PSI MIN. THE INSTRUMENT SET BETWEEN 18,000 AND 22,000 VOLTS. (15 MPA MIN.) (14.5 MPA MIN.) ELONGATION AT BREAK 200% MIN. 200% MIN. SHORE DUROMETER, TYPE D 1 -SEC. 50 -60 t5 (WITH RESPECT TO INITIAL TEST RESULT) 10 -SEC. 35 -50 t5 WEIGHT CHANGE BE CONSOLIDATED BY VIBRATORY OR MECHANICAL TAMPING AND THE EQUIPMENT AND t1.5 TENSILE SPECIMENS SHALL BE PREPARED AND TESTED IN ACCORDANCE WITH ASTM D412 USING DIE B. WEIGHT CHANGE SPECIMENS SHALL BE 1 -INCH (25 -MM) BY 3 -INCH (75 -MM) SAMPLES. SPECIMENS FOR TESTING OF INITIAL PHYSICAL PROPERTIES MAY BE TAKEN FROM LINER PLATE SHEET AND WELDING STRIP AT ANY TIME PRIOR TO FINAL ACCEPTANCE OF THE WORK. LINER PLATE LOCKING EXTENSIONS EMBEDDED IN CONCRETE SHALL WITHSTAND A TEST PULL OF AT LEAST 100 POUNDS PER LINEAR INCH (1800 KG /M), APPLIED PERPENDICULARLY TO THE CONCRETE SURFACE FOR A PERIOD OF ONE MINUTE, WITHOUT RUPTURE OF THE LOCKING EXTENSIONS OR WITHDRAWAL FROM EMBEDMENT. THIS TEST SHALL BE MADE AT A TEMPERATURE OF 70' - 80' F(21' - 27' C) INCLUSIVE. ALL PLASTIC LINER PLATE SHEETS, INCLUDING LOCKING EXTENSIONS, ALL JOINT, CORNER AND WELDING STRIPS SHALL BE FREE OF CRACKS, CLEAVAGES OR OTHER DEFECTS ADVERSELY AFFECTING THE PROTECTIVE CHARACTERISTICS OF THE MATERIAL. THE ENGINEER MAY AUTHORIZE THE REPAIR OF SUCH DEFECTS BY APPROVED METHODS. THE LINING SHALL HAVE GOOD IMPACT RESISTANCE, SHALL BE FLEXIBLE AND SHALL HAVE AN ELONGATION SUFFICIENT TO BRIDGE UP TO 1/4 -INCH (6 MM) SETTLING CRACKS, WHICH MAY OCCUR IN THE PIPE OR IN THE JOINT AFTER INSTALLATIONS, WITHOUT DAMAGE TO THE LINING. 1.C. CHEMICAL RESISTANCE OF UNER.* AFTER CONDITIONING TO CONSTANT WEIGHT AT 110 F(43 C), TENSILE SPECIMENS AND WEIGHT CHANGE SPECIMENS SHALL BE EXPOSED TO THE FOLLOWING SOLUTIONS FOR A PERIOD OF 112 DAYS AT 77' F t5 (25' C t3 ). AT 28 -DAY INTERVALS, TENSILE SPECIMENS AND WEIGHT CHANGE SPECIMENS SHALL BE REMOVED FROM EACH OF THE CHEMICAL SOLUTIONS AND TESTED IN ACCORDANCE WITH SECTION 7- 2.03(1.8) PARA. 2 ABOVE. IF ANY SPECIMEN FAILS TO MEET THE 112 -DAY REQUIREMENTS BEFORE COMPLETION OF THE 112 -DAY EXPOSURE, THE MATERIAL WILL BE SUBJECT TO REJECTION. CHEMICAL SOLUTION SULFURIC ACID SODIUM HYDROXIDE AMMONIUM HYDROXIDE NITRIC ACID FERRIC CHLORIDE 1% SOAP DETERGENT (LINEAR ALKYL BENZYL SULFONATE OR AS BACTERIOLOGICAL CONCENTRATION 20% ** 5% 5 % ** 1 % ** 1% 0.1% 0.1% BOD NOT LESS THAN 700 PPM *THIS IS TO BE USED AS A PRE - QUALIFICATION TEST AND WHEN MATERIAL FORMULATIONS ARE CHANGED. * *VOLUMETRIC PERCENTAGES OF CONCENTRATED C.P. GRADE REAGENTS. 1.D. DETAILS AND DIMENSIONS OF LINER SHEETS. LINER SHEETS SHALL BE A MINIMUM OF 0.065 INCH (1.65 MM) IN THICKNESS. LOCKING EXTENSIONS OF THE SAME MATERIAL AS THAT OF THE LINER SHALL BE INTEGRALLY EXTRUDED WITH THE SHEET. I.E. INSTALLATION OF LINING. INSTALLATION OF THE LINING, INCLUDING PREHEATING OF SHEETS IN COLD WEATHER AND THE WELDING OF ALL JOINTS, SHALL BE DONE IN ACCORDANCE WITH THE RECOMMENDATIONS OF THE LINER MANUFACTURER. COVERAGE OF THE LINING SHALL NOT BE LESS THAN THE MINIMUM SHOWN ON THE PANS. THE LINING SHALL BE INSTALLED WITH THE LOCKING EXTENSIONS RUNNING PARALLEL WITH THE LONGITUDINAL AXIS OF THE PIPE. THE LINING SHALL BE HELD SNUGLY IN PLACE AGAINST INNER FORMS. LOCKING EXTENSION SHALL TERMINATE NOT MORE THAN 1 -1/2 INCHES (38 MM) FROM THE END OF THE INSIDE SURFACE OF THE PIPE SECTION. JOINT FLAPS WHEN USED SHALL EXTEND APPROXIMATELY 4 INCHES (100 MM) BEYOND THE END OF THE INSIDE SURFACE. CONCRETE POURED AGAINST LINING SHALL BE VIBRATED, SPADED OR COMPACTED IN A CAREFUL MANNER SO AS TO PROTECT THE LINING AND PRODUCE A DENSE, HOMOGENOUS CONCRETE, SECURELY ANCHORING THE LOCKING EXTENSIONS INTO THE CONCRETE. IN REMOVING FORMS, CARE SHOULD BE TAKEN TO PROTECT THE LINING FROM DAMAGE. SHARP INSTRUMENTS SHALL NOT BE USED TO PRY FORMS FROM LINED SURFACES. WHEN FORMS ARE REMOVED, ANY NAILS THAT REMAIN IN THE LINING SHALL BE PULLED, WITHOUT TEARING THE LINING, AND THE RESULTING HOLES CLEARLY MARKED. ALL NAIL AND 11E HOLES AND ALL CUT, TORN AND SERIOUSLY ABRADED AREAS IN THE LINING SHALL BE PATCHED. PATCHES MADE ENTIRELY WITH WELDING STRIP SHALL BE FUSED TO THE LINER OVER THE ENTIRE PATCH AREA. LARGER PATCHES MAY CONSIST OF SMOOTH LINER SHEET APPLIED OVER THE DAMAGED AREA WITH ADHESIVE. ALL EDGES MUST BE COVERED WITH WELDING STRIP FUSED TO THE PATCH AND THE SOUND LINING ADJOINING THE DAMAGED AREA. HOT JOINT COMPOUNDS, SUCH AS COAL TAR, SHALL NOT BE POURED OR APPUED TO THE LINING. THE CONTRACTOR SHALL TAKE AU_ NECESSARY MEASURES TO PREVENT DAMAGE TO INSTALLED LINING FROM EQUIPMENT AND MATERIALS USED IN OR TAKEN THROUGH THE WORK. 1.F APPUCAIION TO CONCRETE PIPE - SPECIAL REQUIREMENTS. THE LINING SHALL BE SET FLUSH WITH THE INNER EDGE OF THE BELL OR SPIGOT END OF A PIPE SECTION AND SHALL EXTEND TO THE OPPOSITE END OR TO APPROXIMATELY 4 INCHES (100 MM) BEYOND THE OPPOSITE END DEPENDING UPON THE TYPE OF LINING JOINT TO BE MADE WITH THE ADJOINING CONCRETE PIPE. WHEREVER CONCRETE PIPE OR CAST -IN -PLACE STRUCTURES PROTECTED WITH LINING, JOIN STRUCTURES NOT SO LINED (SUCH AS BRICK STRUCTURES, CONCRETE PIPE OR CAST -IN -PLACE STRUCTURES WITH CLAY LINING OR CLAY PIPE), THE UNING SHALL BE EXTENDED OVER AND AROUND THE END OF THE PIPE AND BACK INTO THE STRUCTURE FOR NOT LESS THAN 4 INCHES (100 MM). THIS PROTECTING CAP MAY BE MOLDED OR FABRICATED FROM THE LINING MATERIAL BUT NEED NOT BE LOCKED INTO THE PIPE. WHERE A PIPE LATERAL (NOT OF PLASTIC LINED CONCRETE) IS INSTALLED THROUGH LINED CONCRETE PIPE, THE SEAL BETWEEN THE LINED PORTION AND THE LATERAL SHAD_ BE PER THE MANUFACTURER'S RECOMMENDATIONS. LINED CONCRETE PIPE MAY BE CURED BY STANDARD CURING METHODS. CARE SHALL BE EXERCISED IN HANDLING, TRANSPORTING AND PLACING LINED PIPE TO PREVENT DAMAGE TO THE UNING. NO INTERIOR HOOKS OR SLINGS SHALL BE USED IN UTTING PIPE. ALL HANDLING OPERATION SHALL BE DONE WITH AN EXTERIOR SUNG OR WITH A SUITABLE FORK LIFT. ON PIPE HAVING A 360' LINER COVERAGE, THE LONGITUDINAL EDGES OF THE SHEET SHALL BE BUTT WELDED. WHEN PIPE TUBES ARE FURNISHED, THESE ARE SHOP- WELDED JOINTS. NO PIPE WITH DAMAGED LINING WILL BE ACCEPTED UNTIL THE DAMAGE HAS BEEN REPAIRED TO THE SATISFACTION OF THE ENGINEER. 1.G. FIELD JOINTS IN LINING FOR CONCRETE PIPE. THE JOINT BETWEEN SECTIONS OF UNED PIPE SHALL BE PREPARED IN THE FOLLOWING MANNER: IF REQUIRED, THE INSIDE JOINT SHALL BE FILLED AND CAREFULLY POINTED WITH CEMENT MORTAR IN SUCH A MANNER THAT THE MORTAR SHALL NOT, AT ANY POINT, EXTEND INTO THE PIPE BEYOND THE STRAIGHT LINE CONNECTING THE SURFACES OF THE ADJACENT PIPE SECTIONS. PIPE JOINTS MUST BE DRY BEFORE LINING JOINTS ARE MADE. ALL MORTAR AND OTHER FOREIGN MATERIAL SHALL BE REMOVED FROM LINING SURFACES ADJACENT TO THE PIPE JOINT, LEAVING THEM CLEAN AND DRY. FIELD JOINTS IN THE LINING AT PIPE JOINTS MAY BE EITHER OF THE FOLLOWING DESCRIBED TYPES: TYPE P -1: THE JOINT SHALL BE MADE WITH A SEPARATE 4 -INCH (100 -MM) JOINT STRIP AND TWO WELDING STRIPS. THE 4 -INCH (100 -MM) JOINT STRIP SHALL BE CENTERED OVER THE JOINT, HEAT - SEALED TO THE UNING, THEN WELDED ALONG EACH EDGE TO ADJACENT LINER SHEETS WITH A 1 -INCH (25 -MM) WELD STRIP. THE 4 -INCH (100 -MM) JOINT STRIP SHALL LAP OVER EACH SHEET A MINIMUM OF 1/2 INCH (13 MM). TYPE P -2: THE JOINT SHALL BE MADE NTH A JOINT FLAP WITH LOCKING EXTENSIONS REMOVED AND EXTENDING APPROXIMATELY 4 INCHES (100 MM) BEYOND THE PIPE END. THE JOINT FLAP SHALL OVERLAP THE LINING IN THE ADJACENT PIPE SECTION A MINIMUM OF 1/2 INCH (13 MM) AND BE HEAT - SEALED IN PLACE PRIOR TO WELDING. THE FIELD JOINT SHALL BE COMPLETED BY WELDING THE FLAP TO THE LINING OF THE ADJACENT PIPE USING 1 -INCH (25 -MM) WELD STRIP. CARE SHALL BE TAKEN TO PROTECT THE FLAP FROM DAMAGE. EXCESSIVE TENSION AND DISTORTION IN BENDING BACK THE FLAP TO EXPOSE THE PIPE JOINT DURING LAYING AND JOINT MORTARING SHALL BE AVOIDED. AT TEMPERATURES BELOW 50 F(10 C), HEATING OF THE LINER MAY BE REQUIRED TO AVOID DAMAGE. THE JOINT FLAP OR STRIP ON BEVELED PIPE SHALL BE TRIMMED TO A WIDTH (MEASURED FROM THE END OF THE SPIGOT) OF APPROXIMATELY 4 INCHES (100 MM) FOR THE ENTIRE CIRCUMFERENTIAL LENGTH OF THE LINING. ALL WELDING OF JOINTS IS TO BE IN STRICT CONFORMANCE WITH THE SPECIFICATIONS AND INSTRUCTIONS OF THE LINING MANUFACTURER. WELDING SHALL FUSE BOTH SHEETS AND WELD STRIP TOGETHER TO PROVIDE A CONTINUOUS JOINT EQUAL IN CORROSION RESISTANCE AND IMPERMEABILITY TO THE LINER PLATE. HOT -AIR WELDING TOOLS SHALL PROVIDE EFFLUENT AIR TO THE SHEETS TO BE JOINED AT A TEMPERATURE BETWEEN 500 AND 600 F (260 AND 316 C). WELDING TOOLS SHALL BE HELD APPROXIMATELY 1/2 INCH (13 MM) FROM AND MOVED BACK AND FORTH OVER THE JUNCTION OF THE TWO MATERIALS TO BE JOINED. THE WELDING TOOL SHALL BE MOVED SLOWLY ENOUGH AS THE WELD PROGRESSES TO CAUSE A SMALL BEAD OF MOLTEN MATERIAL TO BE VISIBLE ALONG BOTH EDGES AND IN FRONT OF THE WELD STRIP. THE FOLLOWING SPECIAL REQUIREMENT SHALL APPLY WHEN THE LINER COVERAGE IS 360 DEGREES: WHEN GROUNDWATER IS ENCOUNTERED THE LINING JOINT SHALL NOT BE MADE UNTIL PUMPING OF GROUNDWATER HAS BEEN DISCONTINUED FOR AT LEAST THREE DAYS AND NO VISIBLE LEAKAGE IS EVIDENT AT THE JOINT. WHEN WELDING THE DOWNSTREAM SIDE OF A JOINT STRIP OR FLAP, DO NOT WELD 6 TO 8 INCHES (150 TO 200 MM) AT THE PIPE INVERT TO PROVIDE RELIEF OF POTENTIAL FUTURE GROUNDWATER BUILD -UP. 1.H. APPLICATION TO CAST -IN -PLACE CONCRETE STRUCTURES - SPECIAL REQUIREMENTS. LINER SHEETS SHALL BE CLOSELY FITTED AND PROPERLY SECURED TO THE INNER FORMS. SHEETS SHALL BE CUT TO FIT CURVED AND WARPED SURFACES USING A MINIMUM NUMBER OF SEPARATE PIECES. UNLESS OTHERWISE SHOWN ON THE PANS„ THE LINING SHALL BE RETURNED AT LEAST 3 INCHES (75 MM) AT THE SURFACES OF CONTACT BETWEEN THE CONCRETE STRUCTURE AND ITEMS NOT OF CONCRETE (INCLUDING MANHOLE FRAMES, GATE GUIDES, CLAY PIPE OR BRICK MANHOLES AND CLAY OR CAST IRON PIPES). THE SAME PROCEDURE SHALL BE FOLLOWED AT JOINTS WHERE THE TYPE OF PROTECTIVE UNING IS CHANGED OR THE NEW WORK IS BUILT TO JOIN EXISTING UNLINED CONCRETE. AT EACH RETURN, THE RETURNED LINER SHALL BE SEALED TO THE ITEM IN CONTACT WITH THE PLASTIC -LINED CONCRETE. IF THE LINER CANNOT BE SEALED WITH ADHESIVE BECAUSE OF THE JOINT AT THE RETURN BEING TOO WIDE OR ROUGH OR BECAUSE OF SAFETY REGULATIONS, THE JOINT SPACE SHALL BE DENSELY CAULKED WITH LEAD WOOL OR OTHER APPROVED CAULKING MATERIAL TO A DEPTH OF 2 INCHES (50 MM) AND FINISHED WITH A MINIMUM OF 1 INCH 925 MM) OF AN APPROVED CORROSION RESISTANT MATERIAL 1.1. TESTING AND REPAIRING DAMAGED SURFACES. AFTER THE PIPE IS INSTALLED IN THE TRENCH, ALL SURFACES COVERED WITH LINING, INCLUDING WELDS, SHALL CONTRACTOR SHALL SHOVEL -SUCE OR HAND TAMP BEDDING IN THE HAUNCH AREAS, AS THIS WILL MINIMIZE VOIDS BENEATH THE PIPE AND IN THE HAUNCH AREAS. 13. ALL SEWER STUBS SHALL BE CLOSED WITH A STANDARD PLASTIC PLUG. SOLVENT WELDED. BE TESTED WITH AN APPROVED, CONTRACTOR SUPPLIED, ELECTRICAL HOLIDAY DETECTOR (TINKER & RASOR MODEL NO. AP -W WITH POWER PACK OR APPROVED EQUAL) WITH SHOVEL- SLICING OR HAND TAMPING SHALL BE DONE BEFORE THE BEDDING IS BROUGHT UP TO THE QUARTER POINT OF THE PIPE. 14. ALL MANHOLES SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE CITY OF BAKERSFIELD STANDARD THE INSTRUMENT SET BETWEEN 18,000 AND 22,000 VOLTS. DRAWINGS S -7, S -8, AND S -21 AND SECTIONS 70 -1.02H AND 71 -1.07 OF THE ALL WELDS SHALL BE PHYSICALLY TESTED BY A NONDESTRUCTIVE PROBING METHOD. INITIAL BACKFI I _ -BEDDING MATERIAL- AS SPECIFIED BY ASTM 2321 -8 SHALL BE USED IN THE PIPE ZONE FOR INITIAL BACKFILL. AFTER THE PIPE HAS BEEN PROPERLY AID STANDARD SPECIFICATIONS OF THE STATE OF CALIFORNIA, DEPARTMENT OF TRANSPORTATION, CURRENT EDITION. ALL CLEANOUTS SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE CITY ALL PATCHES OVER HOLES, OR REPAIRS TO THE LINER WHEREVER DAMAGE HAS AND INSPECTED, INITIAL BACKFILL SHALL BE PACED ON BOTH SIDES AND OVER THE OF BAKERSFIELD STANDARD DRAWING S -20. OCCURRED, SHALL BE ACCOMPLISHED IN ACCORDANCE WITH SECTION 7- 2.03(1.E) PARA. 8 ABOVE. PIPE TO SUCH A DEPTH THAT, AFTER THOROUGH CONSOLIDATION, THE FINAL DEPTH SHALL BE AT LEAST TO THE ELEVATION SHOWN ON THE PANS. THE MATERIAL SHALL MANHOLES SHALL BE TYPE "A" FOR PIPES UNDER 48" IN DIAMETER AND TYPE "B" FOR BE CONSOLIDATED BY VIBRATORY OR MECHANICAL TAMPING AND THE EQUIPMENT AND PIPES 48" IN DIAMETER OR LARGER. UNLESS NOTED OTHERWISE. THE BOTTOM MANHOLE EACH TRANSVERSE WELDING STRIP WHICH EXTENDS TO A LOWER EDGE OF THE LINER MANNER OF TAMPING MUST BE APPROVED IN WRITING BY THE ENGINEER PRIOR TO BARREL AT THE MANHOLE FOUNDATION SHALL BE SET ON A 2" MORTAR BED OR SET ON WILL BE TESTED BY THE PURCHASING AGENCY. THE WELDING STRIPS SHALL EXTEND 2 COMMENCING OPERATION. IMPACT EQUIPMENT MAY BE ALLOWED UNDER THE DIRECTION KENT -SEAL, IN A GROOVED FOUNDATION. INCHES (50 MM) BELOW THE LINER TO PROVIDE A TAB. A 10 -POUND (5 KG) PULL OF THE ENGINEER. HOWEVER, THE CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE WILL BE APPLIED TO EACH TAB. THE FORCE WILL BE APPUED NORMAL TO THE FACE OF RESULTING FROM THE USE OF THIS EQUIPMENT. HYDRA - HAMMER WILL NOT BE PERMITTED. 15. STORM DRAIN PIPE THE STRUCTURE BY MEANS OF A SPRING BALANCE. LINER ADJOINING THE WELDING STRIP WILL BE HELD AGAINST THE CONCRETE DURING APPLICATION THE FORCE. THE STORM DRAIN PIPE. CONTRACTOR SHALL UTILIZE RCP PIPE, CLASS III WITH RUBBER 10 -POUND (5 KG) PULL WILL BE MAINTAINED IF A WELD FAILURE DEVELOPS, UNTIL NO FURTHER SEPARATION OCCURS. SUBSEQUENT BACKED I ABOVE THE LEVEL OF INITIAL BACKFILL, THE TRENCH MAY BE BACKFILLED WITH NATIVE MATERIAL RESULTING FROM TRENCH EXCAVATION, OR AT THE GASKET JOINTS PER ASTM SPECIFICATION C -76, UNLESS OTHERWISE NOTED ON THE CONTRACT PLANS. DEFECTIVE WELDS WILL BE RETESTED AFTER REPAIRS HAVE BEEN MADE. TABS SHALL BE TRIMMED AWAY NEATLY BY THE INSTALLER OF THE LINER AFTER THE WELDING OPTION OF THE CONTRACTOR, SELECT IMPORTED MATERIALS MAY BE USED. NATIVE MATERIAL OR IMPORTED MATERIAL MAY BE COMPACTED BY TAMPING REINFORCED CONCRETE PIPE. REINFORCED CONCRETE STRIP HAS PASSED INSPECTION. INSPECTION SHALL BE MADE WITHIN 2 DAYS AFTER THE JOINT HAS BEEN COMPLETED IN ORDER TO PREVENT TEARING AND /OR ROLUNG, USING EQUIPMENT AND METHODS APPROVED BY THE ENGINEER. PIPE SHALL CONFORM TO THE PROVISIONS IN SECTION 65, -REINFORCED CONCRETE PIPE ", OF THE STANDARD THE PROJECTING THE LINER FROM WELD STRIP AND CONSEQUENT DAMAGE THE SPECIFICATIONS AND THESE SPECIAL PROVISIONS. EQUIPMENT T AND MATERIALS USED IN OR TAKEN THROUGH T T WORK. WHEN THE CONTRACTOR COMPACTS BY TAMPING AND /OR ROLLING, THE BACKFILL SHALL BE PLACED IN LAYERS NOT EXCEEDING EIGHTEEN (18) INCHES IN LOOSE EXCEPT AS OTHERWISE DESIGNATED BY CLASSIFICATION ON THE PANS OR IN THE HOP DRAWINGS. CONTRACTOR SHALL SUBMIT MANUFACTURER INFORMATION DEPTH, EACH LAYER BEING THOROUGHLY COMPACTED BY TAMPING AND /OR ROLLING SPECIFICATIONS, JOINTS FOR CULVERT AND DRAINAGE PIPES SHALL CONFORM TO THE SHOWING DIMENSIONAL, MATERIAL AND JOINT CRITERIA TO THE ENGINEER FOR REVIEW. BEFORE SUCCEEDING LAYERS ARE PLACED. PLANS OR SPECIFICATIONS FOR STANDARD JOINTS. PIPE TRENCH CLASSIFICATION. RCP CLASS IV SHALL BE INSTALLED PER ASTM "C ". COMPACTION OF SUBSEQUENT BACKFILL WITHIN TWO AND ONE -HALF (2 -1/2) FEET OF HYDROSTATIC TESTS SPECIFIED BY SECTION 65 -1.08 "LAYING SIPHON AND PRESSURE TRENCH DESIGNATION RCP CLASS V SHALL BE INSTALLED PER ASTM TRENCH "D ". FINISHED PERMANENT SURFACING GRADE SHALL BE ACCOMPLISHED BY TAMPING AND /OR PIPE ", OF THE STANDARD SPECIFICATIONS WILL NOT BE REQUIRED. DESIGNATION ROLLING AS SPECIFIED ABOVE. WHERE THE TRENCH IS WITHIN THE PAVEMENT ON STREETS, THE BACKFILL WITHIN TWO AND ONE -HALF (2 -1/2) FEET OF FINISHED REINFORCED CONCRETE PIPE SHALL HAVE RUBBER GASKETED JOINTS CONFORMING TO "RUBBER PVC FOR PIPE SIZES 18° AND LESS. POLY VINYL CHLORIDE PIPE SHALL MEET PERMANENT GRADE SHALL BE COMPACTED TO NINETY PERCENT (907.) RELATIVE COMPACTION. SECTION 65- 1.068, GASKETED JOINTS ", OF THE STANDARD SPECIFICATIONS. THE FOLLOWING REQUIREMENTS: HANDLING OF MATERIALS. ALL PIPE, FITTINGS, SPECIALS AND CASTINGS MUST BE 1. MATERIAL. PVC PIPE SHALL MEET OR EXCEED ALL REQUIREMENTS SET FORTH SUBSEQUENT BACKFILL PLACED BY TAMPING AND /OR ROLLING SHALL BE FREE FROM STONES OR LUMPS EXCEEDING THREE (3) INCHES IN GREATEST DIMENSIONS, CAREFULLY HANDLED AT ALL TIMES. ONLY SUITABLE AND PROPER EQUIPMENT AND APPLIANCES SHALL BE USED FOR THE SAFE LOADING, HAULING, UNLOADING, HANDLING IN ASTM D 3034 WITH SDR OF 35. EASTOMERIC SEALS AND JOINTS SHALL CONFORM TO ASTM D 3212 AND AS TM VEGETABLE MATTER, OR OTHER UNSATISFACTORY MATERIALS. AND PLACING OF MATERIALS, SPECIAL CARE SHALL BE EXERCISED SO THAT PREFORMED RESILIENT F 477. JOINTS ON PIPE AND FITTINGS WILL NOT BE DAMAGED. ANY PIPE OR FITTING 2. TESTING. MANUFACTURING TESTING METHODS SHALL CONFORM TO ASTM IN NO CASE SHALL JETTING BE ALLOWED FOR BACKFILL COMPACTION WITHIN THE STREET. WITH A JOINT DAMAGED OR FATTENED WILL CAUSE THAT PIPE OR FITTING TO BE REJECTED. F -679 (T- WALL). CERTIFICATES OF COMPLIANCE SHALL BE MADE AVAILABLE TO THE WHEN APPROVED BY THE ENGINEER, JETTING MAY BE USED IN NON- STREET AREAS. ENGINEER. BACKFILL TESTING AND COMPACTION TESTING OF BACKFILL MATERIALS AND COMPACTION "EARTHWORK" PIPE LAYING. NO PIPE SHALL BE LAID UNTIL THE ENGINEER INSPECTS AND APPROVES THE CONDITION OF THE BOTTOM OF THE TRENCH. PIPE SHALL BE INSTALLED IN STRICT 3. INSTALLATION. INSTALLATION OF PIPE SHALL FOLLOW MANUFACTURER'S SHALL BE IN ACCORDANCE WITH SECTION 19, AND SECTION 6 -3, "TESTING ", OF THE STANDARD SPECIFICATIONS, STATE OF CALIFORNIA, DEPARTMENT OF ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. GUIDEUNES, THESE SPECIFICATIONS AND ASTM D 2321 "UNDERGROUND INSTALLATION OF FLEXIBLE THERMOPLASTIC SEWER PIPE. ". PUBLIC WORKS, DIVISION OF HIGHWAYS. EACH LAYER OF BACKFILL MATERIAL SHALL MEET THE COMPACTION, PIPE LAYING SHALL BEGIN FROM THE DOWNSTREAM END OF THE STORM DRAIN OR AS SAND EQUIVALENT, AND GRADATION REQUIREMENTS BEFORE THE NEXT LAYER IS PLACED. DIRECTED BY THE ENGINEER. PIPE LAYING SHALL PROCEED WITH EACH PIECE LAID TRUE 4. FIELD TESTS. IN -FIELD PRESSURE TESTS SHALL CONFORM TO THESE TO LINE AND GRADE, AND IN SUCH A MANNER AS TO FORM A CLOSE CONCENTRIC JOINT SPECIFICATIONS AND THE FOLLOWING: EACH LAYER OF BACKFILL SHALL BE THOROUGHLY COMPACTED TO THE RELATIVE WITH THE ADJOINING PIPE AND TO PREVENT SUDDEN OFFSETS IN THE FLOW LINE. AS THE WORK PROGRESSES, THE INTERIOR OF THE PIPE SHALL BE CLEARED OF ALL DIRT AND DEFLECTION MEASUREMENT OF PVC PIPE. AFTER 30 DAYS OF INSTALLATION THE COMPACTION OF NOT LESS THAN IS SHOWN ON CITY OF BAKERSFIELD STANDARD S -39 AS MODIFIED ON THE CONTRACT PLANS, EXCEPT THAT COMPACTION WITHIN THE DEBRIS OF EVERY DESCRIPTION. PIPE SHALL NOT BE AID WHEN THE CONDITION OF THE TRENCH THE CONTRACTOR SHALL MEASURE PIPE DEFLECTION BY PULUNG A GO -NO -GO 5% MANDREL. THE MANDREL SHALL BE PULLED THROUGH THE PIPE WITH ROPE BY ONE PERSON ROADWAY STRUCTURAL SECTION SHALL BE NO LESS THAN NINETY PERCENT (907.) OR WEATHER IS UNSUITABLE. AT 11MES WHEN WORK IS NOT IN PROGRESS, OPEN ENDS OF PIPE AND FITTINGS SHALL BE CLOSED. WITHOUT MECHANICAL ADVANTAGE. THE MANDREL SHALL HAVE VANES AT LEAST AS LONG AS THE PIPE DIAMETER. THE MANDREL SHALL BE USED IN STRICT CONFORMANCE RELATIVE COMPACTION FOR THE TOP FINISHED 30 ", AND SHALL BE DETERMINED BY CALIFORNIA TEST METHODS 216 OR 231, OR ASTM (CURRENT EDITION) D1557 AND ONE WITH BELLED END PIPE, BELL HOLES SHALL THEN BE EXCAVATED AT EACH JOINT TO WITH PIPE AND MANDREL MANUFACTURER'S RECOMMENDATIONS. THE MANDREL OF THE FOLLOWING D2922 OR D1556. FACILITATE THE JOINT OPERATIONS, AND SHALL BE ONLY OF SUFFICIENT SIZE FOR THAT DIAMETER WILL BE CALCULATED USING THE FOLLOWING FORMULA: IF THE RELATIVE COMPACTION, AS DETERMINED BY TESTING, FAILS TO MEET THE PURPOSE. IN ORDER THAT BELL HOLES MAY BE PROPERLY LOCATED, NOT MORE THAN SIX (6) HOLES SHAD_ BE EXCAVATED AHEAD OF ACTUAL PIPE LAYING, ON ACCOUNT OF MANDREL DIAMETER = BASE PIPE I.D. -(Y /100 X BASE PIPE I.D.) SPECIFIED PERCENTAGE, THE TRENCH SHALL BE RE- EXCAVATED AND RE- COMPACTED. THE VARIATIONS IN JOINT CONSTRUCTION OPERATIONS. WHERE Y = ALLOWABLE DEFLECTION IN % (5 %) BASE I.D. COMPACTION TESTS WILL BE THE SUBDIVIDERS RESPONSIBIUTY. THE NUMBER AND THE CONTRACTOR SHALL MAKE PROVISIONS FOR PREVENTING FOREIGN MATERIAL FROM = ACTUAL INSIDE PIPE DIAMETER (PROVIDED BY PIPE LOCATIONS OF THE TESTS SHALL BE DETERMINED BY THE CITY ENGINEER. BEING FLUSHED INTO AN EXISTING STORM DRAIN UNE. MANUFACTURER) 10. SEWER PIPE INSTALLATION CUTTING PIPE. THE CONTRACTOR SHALL PERFORM ALL WORK OF CUTTING PIPE AND THE MANDREL SHALL HAVE AN ODD NUMBER OF VANES WITH SEVEN (7) MINIMUM. SEWER PIPE SHALL CONFORM TO THE PLANS, AND THESE SPECIAL PROVISIONS. THE SPECIAL CASTING NECESSARY TO THE ASSEMBLY, ERECTION, AND COMPLETION OF THE WORK. ALL PIPE SHALL BE CUT TO FIT ACCURATELY, WITH SMOOTH EDGES AND FACES. PRICE PER LINEAL FOOT SHALL INCLUDE BUT NOT BE UMITED TO EXCAVATION, BEDDING THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE CORRECTNESS OF CUTTING AND NO THE MINIMUM LENGTH OF THE CIRCULAR PORTION OF THE MANDREL SHALL BE AND BACKFILL ADDITIONAL COMPENSATION WILL BE ALLOWED FOR ANY MATERIALS WHICH ARE DAMAGED EQUAL TO THE NOMINAL DIAMETER OF THE PIPE. OR INCORRECTLY CUT. HANDUNG OF MATERIALS. ALL PIPE, FITTINGS, SPECIALS AND CASTINGS MUST BE ANY SECTION OF INSTALLED PIPE THAT FAILS THE MANDREL TEST SHALL BE CAREFULLY HANDLED AT ALL TIMES. ONLY SUITABLE AND PROPER EQUIPMENT AND 16• BORED /JACKED PIPE EXCAVATED, RE- BACKFILLED, RECOMPACTED AND RETESTED UNTIL THE MANDREL TEST APPLIANCES SHALL BE USED FOR THE SAFE LOADING, HAULING, UNLOADING, HANDLING CAN BE PASSED. RE- ROUNDING WILL NOT BE ALLOWED. AND PLACING OF MATERIALS, SPECIAL CARE SHALL BE EXERCISED SO THAT PREFORMED RESILIENT JOINTS ON PIPE AND FITTINGS WILL NOT BE DAMAGED. CASING OR SMOOTH OUTSIDE WALLED PIPE FOR BORED /JACKED PIPE SHALL BE PIPE TRENCH CLASSIFICATION. PVC PIPE SHALL BE INSTALLED PER CITY STANDARD ANY PIPE OR FITTING WITH A JOINT DAMAGED OR FATTENED WILL CAUSE THAT PIPE OR FITTING TO BE INSTALLED. IT SHALL HAVE EVEN BEARING THROUGHOUT ITS LENGTH AND SHALL SLOPE TOWARD ONE END. SPACE BETWEEN CASING AND PIPELINE SHALL BE BACKFILLED WITH S -39, AS MODIFIED ON THE CONTRACT PLANS. COMPACTION ABOVE THE PIPE ZONE SHALL BE AS SHOWN ON THE PLANS. REJECTED. SAND. IF THE PIPE AND CASING ARE INSTALLED BY BORING, THE SPACE AROUND THE 7. TRENCH EXCAVATION PIPE LAYING. NO PIPE SHALL BE LAID UNTIL THE ENGINEER INSPECTS AND APPROVES THE CONDITION OF THE BOTTOM OF THE TRENCH. BETWEEN THE CAS NGBAND THE PIPE SHALL BE SEALED SAND. WITH ROUT.DSTHE STRENGTH THE EXCAVATION OF TRENCHES FOR PIPING LAID IN THE GROUND SHALL BE IN PIPE SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. PIPE LAYING SHALL BEGIN FROM THE DOWNSTREAM END OF THE TRUNK SEWER OR AS DIRECTED BY THE ENGINEER. OF PIPE DESIGNATED IN THE PLANS OR SPECIFICATIONS IS DETERMINED FOR VERTICAL LOAD ONLY ANY ADDITIONAL STRENGTH REQUIRED BY BORING /JACKING OPERATIONS OPEN -CUT FROM THE SURFACE OF THE GROUND EXCEPT WHERE BORING IS REQUIRED. PIPE LAYING SHALL PROCEED WITH EACH PIECE AID TRUE TO LINE AND GRADE, AND IN SHALL BE FURNISHED AT THE CONTRACTOR'S EXPENSE. THE TRENCHES SHALL BE OF WIDTH AS SHOWN ON STANDARD S -39 AND DETAILED SECTIONS ON THE PLANS FOR PROPER PIPE INSTALLATION. SUCH A MANNER AS TO FORM A CLOSE CONCENTRIC JOINT WITH THE ADJOINING PIPE AND TO PREVENT SUDDEN OFFSETS IN THE FLOW LINE. THE CONTRACTOR SHALL SUBMIT TO THE ENGINEER FOR APPROVAL ALL PLANS OF AS THE WORK PROGRESSES, THE INTERIOR OF THE PIPE SHALL BE CLEARED OF ALL DIRT AND DEBRIS OF EVERY BORING /JACKING OPERATIONS PRIOR TO BORING OR JACKING. THE HOLES FOR BELLS AND FITTINGS SHALL BE EXCAVATED BY HAND, TO A WIDTH PROVIDING UNIFORM BEARING ALONG THE LENGTH OF THE PIPE. IT IS THE INTENTION OF DESCRIPTION. PIPE SHALL NOT BE AID WHEN THE CONDITION OF THE TRENCH OR THE WEATHER IS UNSUITABLE. AT TIMES WHEN WORK IS NOT IN PROGRESS, BORING /JACKING OPERATIONS SHALL BE CONDUCTED IN A SAFE AND EFFICIENT MANNER, THESE REQUIREMENTS TO PROVIDE FIRM, UNIFORM BEARING FOR THE PIPE. OPEN ENDS OF PIPE AND FITTINGS SHALL BE CLOSED. CONSISTENT WITH CURRENT ACCEPTED PROCEDURES. WATER BORING SHALL NOT BE PERMITTED. THE CASING PIPE SHALL BE JACKED WITH SUCH PRECISION THAT WILL CONTRACTOR SHALL PROVIDE TRENCHING IN ACCORDANCE WITH THE DETAILED SECTIONS WITH BELLED END PIPE, BELL HOLES SHALL THEN BE EXCAVATED AT EACH JOINT TO ALLOW THE REPLACEMENT OF THE PIPELINE TO THE UNE AND GRADE AS INDICATED ON PROVIDED IN THE PLANS. SELECTION OF TRENCH TYPES WILL BE AS REQUIRED BY THE TYPES OF PIPE SELECTED FOR CONSTRUCTION. FACILITATE THE JOINT OPERATIONS, AND SHALL BE ONLY OF SUFFICIENT SIZE FOR THAT THE PANS. STORM DRAIN AND UTILITY CONDUIT INSTALLATIONS SHALL MEET CITY STANDARD S -39. PURPOSE. IN ORDER THAT BELL HOLES MAY BE PROPERLY LOCATED, NOT MORE THAN SIX (6) HOLES SHALL BE EXCAVATED AHEAD OF ACTUAL PIPE LAYING, UPON COMPLETION OF THE INSTALLATION OF THE CASING AND INSTALLATION OF THE ON ACCOUNT OF THE VARIA1IONS IN JOINT CONSTRUCTION OPERATIONS. PIPELINE TO GRADE, THE VOID BETWEEN THE CASING OR RC PIPE AND THE EXCAVATION TRENCH LINES SHALL MEET ALL FEDERAL AND S TALE SAFETY REQUIREMENTS. SHALL BE COMPLETELY FILLED WITH SAND, COMPACTED BY THE USE OF AIR - BLOWING 8. BRACING AND SHORING CUTTING PIPE. THE CONTRACTOR SHALL PERFORM ALL WORK OF CUTTING PIPE AND SAND EQUIPMENT OR ANY OTHER MEANS ACCEPTABLE TO THE ENGINEER UPON HIS APPROVAL. SPECIAL CASTING NECESSARY TO THE ASSEMBLY, ERECTION, AND COMPLETION OF THE EXCAVATION SHALL BE SUPPORTED AS SET FORTH IN THE RULES, ORDERS, AND WORK. ALL PIPE SHALL BE CUT TO FIT ACCURATELY, WITH SMOOTH EDGES AND FACES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE CORRECTNESS OF CUTTING AND NO IT IS THE CONTRACTOR'S RESPONSIBILITY TO MAINTAIN A SAFE OPERATION AT ALL REGULATIONS OF THE STATE DIVISION OF INDUSTRIAL SAFETY. IF THE CONTRACTOR ADDITIONAL COMPENSATION WILL BE ALLOWED FOR ANY MATERIALS WHICH ARE DAMAGED TIMES. SHOULD THE TUNNEL HEADING OPERATIONS RESULT IN DANGEROUS OR DESIRES TO DEVIATE FROM THE SAFETY ORDERS, HE SHALL SUBMIT DATA BY A OR INCORRECTLY CUT. UNREASONABLE SLOUGHING OF MATERIAL WHICH MAY JEOPARDIZE THE SAFETY OF REGISTERED CIVIL ENGINEER TO THE STATE DIVISION OF INDUSTRIAL SAFETY, JUSTIFYING WORKERS OR THE STABILITY OF THE SOIL AND ROADWAY ABOVE, THE CONTRACTOR THE ALTERNATE PROCEDURES TO BE USED. FAILURE TO COMPLY WITH ANY OF THESE RULES, ORDERS AND REGULATIONS SHALL BE SUFFICIENT CAUSE FOR THE STATE DIVISION PIPELINE TESTING, ALL SEWERS SHALL BE TESTED FOR TIGHTNESS WHEN COMPLETED AND READY FOR SERVICE. TESTING SHALL BE CONDUCTED IN ACCORDANCE NTH THE SHALL FURNISH AND INSTALL BREASTBOARDING AND /OR FACE CLOSURE WITH SUFFICIENT JACKS TO INHIBIT THE SLOUGHING AND /OR CLOSING THE WORK FACE. TO IMMEDIATELY SUSPEND ALL WORK. COMPENSATION FOR LOSSES INCURRED BY THE CONTRACTOR BY SUCH AN EMERGENCY SUSPENSION SHALL NOT BE ALLOWED. DURING UNIFORM PLUMBING CODE AIR TEST METHOD UPC SEC. 318 -6(4), OR THE WATER THE CONTRACTOR, BEFORE RESUMING WORK, SHALL FURNISH THE ENGINEER WITH A DETAILED PLAN OF PRECEDING WITH THE WORK, BACKFILUNG, THE BOTTOM OF THE SHORING SHALL BE KEPT ABOVE THE LEVEL OF THE BACKFILL AT ALL TIMES. EXFILTRATION TEST OR AIR PRESSURE TEST PER SECTION 306 -1.4, "TESTING PIPELINES" OF THE 1994 EDITIONS, "STANDARD SPECIFICATIONS" FOR PUBLIC WORKS CONSTRUCTION, FOR HIS REVIEW AND APPROVAL ANY AND ALL EXPENSES THEREFORE WILL CONSIDERED AS INCLUDED IN THE BID AND CHAPTER 1.3 OF THE CITY OF BAKERSFIELD SUBDIVISION DESIGN MANUAL, AND THE PRICE AND NO ADDITIONAL COMPENSATION WILL BE MADE THEREFORE. WILL SECTION 6422 OF THE CALIFORNIA LABOR CODE REQUIRES THE CONTRACTOR TO SUBMIT PIPE SUPPLIER'S REQUIREMENTS. THE CONTRACTOR SHALL NOTIFY THE ENGINEER 24 17. MINOR STRUCTURES TO THE ENGINEER A DETAILED PLAN, DRAWING THE DESIGN OF SHORING, BRACING, HOURS PRIOR TO ANY TESTING. SLOPING OR OTHER PROVISIONS TO BE MADE BY THE CONTRACTOR FOR THE PURPOSE OF WORKER PROTECTION FROM THE HAZARD OF CAVING GROUND DURING THE CLEANING PIPE LINES. CARE SHALL BE EXERCISED IN APING OF PIPE LINES TO MINOR STRUCTURES. PORTLAND CEMENT CONCRETE MINOR STRUCTURES SHALL CONFORM, IN DESIGN, MATERIALS, AND CONSTRUCTION, TO THE PROVISIONS OF EXCAVATION OF TRENCHES NECESSARY FOR THE CONSTRUCTION OF THE PROJECT. IF SUCH PLAN VARIES FROM THE SHORING SYSTEM STANDARD ESTABLISHED BY THE EXCLUDE DIRT AND ANY OTHER FOREIGN MATERIAL. WHEN PIPE LAYING IS INTERRUPTED, AS AT NIGHT, THE PIPE ENDS SHALL BE SUITABLY CLOSED. UPON COMPLETION, AND SECTIONS 70 -1.02 H OF THE STANDARD SPECIFICATIONS AND THESE SPECIAL PROVISIONS. MANHOLES SHALL CONFORM TO THE CITY OF BAKERSFIELD CONSTRUC110N SAFETY ORDERS, THE PLANS SHALL BE PREPARED AND CERTIFIED BY A REGISTERED CIVIL OR STRUCTURAL ENGINEER; HOWEVER, USE OF SYSTEMS THAT ARE BEFORE PLACING INTO SERVICE, ALL LINES SHALL BE FLUSHED AND MANDRELLED TO REMOVE ANY DIRT OR FOREIGN MATERIALS WHICH WOULD CLOG PUMPS, EQUIPMENT, STANDARDS S -7 AND S -8. DROP INLETS SHALL CONFORM TO THE CITY OF BAKERSFIELD STANDARD S -12. TEMPORARY INLET GRATES SHALL CONFORM TO DETAILS LESS EFFECTIVE THEN THOSE REQUIRED BY THE CONSTRUCTION SAFETY ORDERS IS SPRAY HEADS, ETC. THE CONTRACTOR SHALL MAKE PROVISIONS FOR PREVENTING ON THE PLANS. PROHIBITED ON THIS PROJECT. FOREIGN MATERIAL FROM BEING FLUSHED INTO AN EXISTING SEWER LINE. 9. TRENCH BACKFILL SEWER LATERALS. SEWER LATERALS SHALL CONFORM TO THIS IN EVERY REGARD. EXISTING SEWER LATERALS SHALL BE LOCATED BY THE CONTRACTOR AND CONNECTED TO THE PRECAST CYUNDER, TAPER, AND ECCENTRIC FLAT TOP SECTIONS SHALL MEET THE STRENGTH REQUIREMENT OF ASTM. C -478. EACH SUCCESSIVE MANHOLE SECTION SHALL "KENT TRENCHES SHALL NOT BE LEFT OPEN FARTHER THAN THREE HUNDRED (300) FEET IN COUDPLI GS MAY O E UTILIZED FOR DCONNECTING GTOOE STI GA ATERAOLS.PRP BE SET ON A BED OF PORTLAND CEMENT GROUT OR SEAL" TO MAKE A WATERTIGHT JOINT, SHALL BE NEATLY POINTED ON THE INSIDE, AND SHALL BE SET ADVANCE OF PIPE LAYING OPERATIONS OR TWO HUNDRED (200) FEET TO THE REAR THEREOF, UNLESS OTHERWISE PERMITTED BY THE ENGINEER. POSITIVE GRADE TO THE TRUNK SEWER SHALL BE MAINTAINED AND INVERT GRADES SET AS CALLED ON THE PLANS. SEWER WYES SHALL BE INSTALLED ON THE TRUNK IN ACCORDANCE WITH THE PIPE MANUFACTURERS RECOMMENDATIONS. PAYMENT FOR SEWER LATERALS WILL BE 18. ADJUST SURVEY MONUMENT ENCASEMENTS ALL WORK SHALL CONFORM TO THE APPLICABLE SECTIONS OF THE STANDARD PAID AS SEWER FOR THE APPROPRIATE DIAMETERS. SPECIFICATIONS, DATED JULY, 1992. BEDDING CLASS SHALL BE AS SPECIFIED IN THE SURVEY MONUMENT AND FRAME AND COVER WITH ENCASEMENTS SHALL BE ADJUSTED OR PIPE OPTIONS. STORM DRAIN AND UTILITY CONDUIT INSTALLATIONS TIONS SHALL BE IN NEW TO FINISH GRADE AT THE LOCATIONS SHOWN ON THE P LAN PLANS, IN ACCORDANCE WITH CITY STANDARD ST -22, EXCEPT THAT COMPACTION SHALL BE NO LESS 11. SYSTEM TESTING ACCORDANCE WITH THESE SPECIAL PROVISIONS, AND CITY STANDARD 5 THAN NINETY PERCENT (907.) UP TO THIRTY INCHES (30 ") FROM FINISHED GRADE. A MANDREL TEST AND PRESSURE TEST SHALL BE PERFORMED ON INSTALLED PIPE THE SURFACE OF THE CONCRETE SHALL BE PROTECTED FROM PUBLIC TRAFFIC FOR A BACKFILL MATERIALS IN THE PIPE ZONE SHALL BE PLACED IN LAYERS NOT TO EXCEED IN ACCORDANCE WITH THE CITY OF BAKERSFIELD SUBDIVISION MANUAL AND THE MINIMUM OF THREE DAYS. TWELVE (12) INCHES SIMULTANEOUSLY, ON EACH SIDE OF THE PIPE, IN SUCH A MANNER RECOMMENDATIONS OF THE MANUFACTURER. AS NOT TO DAMAGE OR DISTURB THE PIPE OR ITS ALIGNMENT AND GRADE. AT THE OPTION OF THE CONTRACTOR, MINOR CONCRETE CONTAINING A MINIMUM OF PRIOR TO FINAL ACCEPTANCE, ALL SEWER UNES SHALL BE INSPECTED WITH VIDEO EQUIPMENT SEVEN SACKS OF CEMENT PER CUBIC YARD MAY BE USED AND THE TIME REQUIRED FOR BACKFILL MATERIAL ABOVE THE PIPE ZONE SHALL BE FREE OF DELETERIOUS MATERIALS DESIGNED FOR THIS PURPOSE. THE TELEVISION CAMERA SHALL HAVE THE CAPABILITY OF ROTATING PROTECTION OF THE CONCRETE SURFACE FROM PUBLIC TRAFFIC SHALL BE REDUCED TO AND LUMPS OR STONES EXCEEDING THREE (3) INCHES IN GREATEST DIMENSION AND 360', IN ORDER TO VIEW AND RECORD THE TOP AND SIDES OF THE PIPE, AS REQUIRED. THE VIDEO A MINIMUM OF ONE DAY. SHALL BE PLACED IN LAYERS NOT EXCEEDING EIGHTEEN (18) INCHES. EACH LAYER SHALL BE THOROUGHLY COMPACTED BY VIBRATORY OR MECHANICAL TAMPING, INSPECTION SHALL BE WITNESSED BY THE CITYS CONSTRUCTION INSPECTOR, WHO WILL ALSO INITIAL AND DATE THE "CHAIN OF CUSTODY" FORM. THE SUBDIVIDER SHALL IMMEDIATELY NOTIFY CITY OF THE MONUMENT WILL BE SET BY OTHERS. THE OWNER WILL PROVIDE SURVEYS. OR BY A COMBINATION OF THESE METHODS. FLOODING AND JETTING SHALL NOT BE ALLOWED. ANY PIPE LOCATIONS REVEALED TO BE NOT IN COMPLIANCE WITH THE SPECIFICATIONS. A RECORDED CONTRACTOR SHALL GIVE THE OWNER 24 HOURS NOTICE WHEN SURVEYS ARE REQUIRED. THERE MUST BE AT LEAST ONE FOOT OF COVER OVER THE PIPE BEFORE COMPACTION VIDEO CASSET E, THE COMPLETED "CHAIN OF CUSTODY" FORM AND A WRITTEN LOG (WHICH INCLUDES ABOVE THE PIPE ZONE WILL BE ALLOWED. THE STATIONING, BASED ON THE STATIONING OF THE APPROVED PLANS, OF ALL CONNECTED LATERALS ) OF THE INSPECTION SHALL BE PROVIDED FOR VIEWING, ANY MONUMENT FRAME OR COVER DAMAGED BY THE CONTRACTOR OR HIS OPERATIONS SHALL BE REPLACED BY THE CONTRACTOR AT NO COST TO THE OWNER. IMPORTED BEDDING AND BACKFILL MATERIAL SHALL BE OBTAINED, AND ANY EXCESS AND SHALL BE APPROVED BY THE CITY ENGINEER PRIOR TO ACCEPTANCE. AFTER ACCEPTANCE, THE VIDEO CASSETTE SHALL BECOME THE PROPERTY OF BEDDING AND BACKFILL MATERIAL SHALL BE DISPOSED, BY ANY LEGAL MEANS AT THE THE CITY' AN OPEN STREET T PERMIT S HALL BE OBTAINED FROM THE CITY OF BAKERSFIELD DISPOSAL OF THE CONTRACTOR. IS PUBLIC WORKS PR FOR ANY WORK PERFORMED WITHIN ACCEPTED STREET 12. WYE FITTINGS SHALL BE INJECTION MOLDED IN -LINE TYPE AND SHALL BE USED FOR ALL RIGHT -OF -WAY. UNLESS SECURED BY A SUBDIVISION AGREEMENT, A DEPOSIT THE CONTRACTOR MAY SUBMIT TO THE ENGINEER SIEVE ANALYSIS FOR UTILIZATION OF LATERAL CONNECTIONS AND SHALL BE ROTATED A MINIMUM OF 23 DEGREES ABOVE THE BASED ON APPROVED ENGINEER'S ESTIMATE FOR THE WORK PERFORMED WITHIN THE IN -SITU MATERIALS. HORIZONTAL PLANE RUNNING THROUGH THE CENTERLINE OF THE MAIN. RIGHT -OF -WAY AND INSURANCE SHALL BE POSTED PRIOR TO ISSUANCE OF THE PERMIT. ACHIEVING FIRM BEDDING BELOW PIPE SPRINGLINE CONTRACTOR SHALL PROVIDE "FIRM ALL LATERALS SHALL BE 4" IN DIAMETER EXCEPT AS NOTED ON PLANS, EXTENDING A MINIMUM BEDDING" SUPPORT FOR THE PIPE BELOW THE SPRINGUNE, FIRM BEDDING MEANS THAT OF 4' BEYOND THE PROPERTY LINE OR RIGHT -OF -WAY LINE WITH 30" OF COVER AT FLOW UNE. THE PIPE MUST REST ON THE GRANULAR MATERIAL SPECIFIED PREVIOUSLY IN THE SPECIFICATIONS. SURFACE MARKERS FOR SEWER LATERALS SHALL BE INSTALLED AT THE PROPERTY UNE OR RIGHT -OF- BELL OR COUPLING HOLES SHALL BE CAREFULLY EXCAVATED AT PROPER INTERVALS, SO WAY LINE AS SHOWN IN THE "SEWER LATERAL MARKER" DETAIL, C.O.B. STD. DET. SW -1. THAT NO PART OF THE LOAD IS SUPPORTED BY THE BELLS OR COUPLINGS. DURING BEDDING AND BACKFILUNG, CONSOLIDATION OF MATERIAL AROUND AND LATERALS SHALL BE A MINIMUM OF 2.25' DEEP AND A MAXIMUM OF 7' DEEP AT PROPERTY LINE OR RIGHT UNDER BELLS AND COUPLINGS SHALL BE AVOIDED. -OF -WAY LINE AND A MINIMUM OF 2.5' DEEP AT FLOWUNE. ld -,All Pk F H A 5 , I 344 1 � 342 i 340 338 INVERT 18" DRAIN 336 A SECTION 3 SCALE: 1" = 50' HORIZ. 1" = 5' VERT. INSTALL 17.37 LF OF 18" RCP ® 0.12% L H A i r II S8912'10" ESBE "" INER ��o �A� Lu �0 F -0 J p J p I�o 0 1 41 0 oil o M 10 Mo�0 11 IoM O Iz`n o rn1 z Z O - Z 0 IMO 120 :o�° 13 Mw� <' Q+ o IN -'n zJolQ'n N o, J of Q No, I >> i € WW Q U L p 0 0 N Z I O .+ Z t N O I o rn Z N I� Z cr a z) 1 1¢- 1 ,� Q U) � N t a I I -- I -- cn I N - -y ! En o a N �f-` CD 7R - - -y -- 0U20'M - +,N� Ui ro sn 8 � 12 +00 13 +00 24" SD N8912'08 "W 1 .80' 0 `+°con l'_ a °a°° » -- -- f- - _ Q ' Z I — N8912'10'W- - - I 344 1 � 342 i 340 338 INVERT 18" DRAIN 336 A SECTION 3 SCALE: 1" = 50' HORIZ. 1" = 5' VERT. INSTALL 17.37 LF OF 18" RCP ® 0.12% L H A i r II S8912'10" ESBE "" INER 185.22' �A� Lu Z oN-co Z M II OJ _ 0 rn • II w� z > > J W I z Z O - Z 0 Z • 00 0) z Vt w o J Lq <' Q+ '- 01 00 M 00 Q mn-i U•i I J O VrnmNl J oa ww 0 a 348 I >> i € WW Q U it O aQOzl UH. Z X I O M v o i I o rn a. U( I of O N Io:O I N I ,, aYO °I1-o aY O o 14 Mo �0 15 Nd °z_MJ O IN3 I Q_ I 18 Qo19Ma p +O 0U20'M 42 +,N� 9 ro sn 8 � Ooi3��N 7 6 `+°con l'_ a °a°° » -- -- f- - _ Q ' Z I ,.O I 1 I o,N3 Nr- v ^JAI 1�t°n VWi (n N � M� U�Ow I o� I I N W I r r� 1 VI I z+ r7 w + 0 + O INSTALL 25.71 LF OF J I ¢ I I - I v N 18" RCP ® 0.12% I (~n I � I < , d Z if Z I (fl Z a + co t Z I Z d m a N$ I rn ^N 0 ►- 1- F- I F I 0 z o w N 3 C' z TRACT BOUNDARY' 00mm o� ON.0 <U Z Z Z (O ZU Z c z O aD cV o0 Z O ln Q wU) rl i N N N 066 06 1n Q� 1- N O 0+r7 't n r mn� W W W U ~ > O in Q VS W W W U J (n W I 344 1 � 342 i 340 338 INVERT 18" DRAIN 336 A SECTION 3 SCALE: 1" = 50' HORIZ. 1" = 5' VERT. INSTALL 17.37 LF OF 18" RCP ® 0.12% L H A i r II -; C) ZJ z3 �A� Lu Z oN-co Z M II OJ _ - rn • II w� z > > J W I z Z O - Z W 2 . - Z • 00 0) z Vt w o J Lq <' Q+ '- 01 00 M 00 Q mn-i W W O I J O VrnmNl J oa ww 0 a 348 I >> i € WW Q U owJ A Z Q W 344 342 I ' ' I 340 338 INVERT 18" DRAIN 336 B SECTION 3 SCALE: 1" = 50' HORIZ. 1" = 5' VERT. 346 APPROXIMATE FINISHED GRADE ® CENTERLINE I 342 INVERT 24" DRAIN 338 • ' 334 IN S. _ I 00 r 330 V) w z J 326 Q I d I 322 INSTALL 185.22 LF OF 8" ® 0.48% 1 O zJw3 w . J O N z J Q > > -zz Z , in In Q 00 m MM uj Q J J V1 w w .CA T.03- jJ H A �i> r II -; C) I 1 -zzz lolly Z oN-co Z r �� J � -tdC04 � N II II 1 r ci 06 I ZUJJI I I (fl . IF�3 U Q 00 + J IJ p 1J' m + _j a I J o W I J O VrnmNl J I Z�' a; I ON zp? I >> i € J N o M 10 M aQOzl UH. Z X I O M v o i I o rn a. I o M o F- ° aw o 14 Mo �0 15 X016 °z_MJ I MW 17 I Q_ 1 18 Qo19Ma p +O 0U20'M I ! I OI 'rn +o° `�N ro sn usC',WJ o � W I I `+°con l'_ a °a°° » -- -- f- - _ Q ' Z I r4ul I,�,n 1 �m v ^JAI 1�t°n VWi (n IU Lnn � M� U�Ow o o� N n I C! 1� I N I r r� , c� 1� I z+ r7 w I J Uri �j v cO d. I0o � t` sr o a,, 1* d Z if Z I (fl Z + co t Z I Z d^ Z N$ I rn ^N ►- F- I F I 0 I cn VOYAGEURS DR. 15 +00 18" SD N891 '08'W 350.48' 16 +00 17 +00 18 +00 18" SD N8?-33 12-W 159.79' 1 1 1 �- I Imo I o N ,o N O CD �? N a 5 +^ 4 I ^ N 0 + co to O VI I IQ 1— IN S8912'10 "E 8" SEE SHEET 5 I1 -; C) Z > > > z > > -zzz 3ooriMl Z oN-co Z r �� J � -tdC04 � N II II 1 r ci 06 rn ZUJJI 0 W W t Q2 1Z `� l Q 00 + + ^T 1J' m + _j a it ' W .-� VrnmNl �-- ,°I a; I ON or, N I >> i € z aZ aQOzl UH. Z X N ■ v o i Of O'� a. o F- ° M u 15 +00 18" SD N891 '08'W 350.48' 16 +00 17 +00 18 +00 18" SD N8?-33 12-W 159.79' 1 1 1 �- I Imo I o N ,o N O CD �? N a 5 +^ 4 I ^ N 0 + co to O VI I IQ 1— IN FORT SANDERS AVENUE (STA. 12 +19.78 TO 21+15.80) SCALE: 1" = 50' HORIZONTAL –_ —._ _T_ -- INSTALL 350.48 LF OF 18' RCP ® 0.12% I 1 U7 O • O zJw(n3 z-1 S8912'10 "E 8" WEIR 385.22' I1 I Z > > > z > > -zzz -zz Z oN-co Z co Coo) Q N N N Q T T r ci 06 Ij a 0 a Q A + ^T VJ W W W Vl it ' c)1w U) .- 3 �-- I '' OJ a; I ON or, N I >> i € z ' >> i O '� N ■ O N 3 Of O'� o o 1 N 3 0I I O 3 , 2 `� 3,�,°n `rN M u I O 3 IzJ(wJ1 I ^ I N- 'Lnl�r;r °z_MJ of m cD i I Q_ �J Li 'm --- a p +O W W I ! I OI 'rn +o° `�N ro sn usC',WJ o � z rn I I `+°con l'_ a °a°° » -- -- f- - _ Q ' Z I I < ++ IW�� W W I 1 ' ? v ^JAI H J J 1 VWi (n W W I IN I IN U�Ow I Wr,I III V1 Ln FORT SANDERS AVENUE (STA. 12 +19.78 TO 21+15.80) SCALE: 1" = 50' HORIZONTAL –_ —._ _T_ -- INSTALL 350.48 LF OF 18' RCP ® 0.12% I 1 U7 O • O zJw(n3 z-1 z3 o "��� o 2J m I Z > > > z > > -zzz -zz Z oN-co Z co Coo) Q N N N Q d t o6 6 c6 of °+ M H M °+ ci 06 M N 0 > ar Q Q 0 J J J 0 J J VJ W W W Vl W W _! _ INSTALL 159.79 LF OF 18" RCP 0 0.13x U) .- 1- J c J :cr C3 5� jU i g no o (n 62 I � J n I " 63 I N N I � o I rn z 20 +00 S86. 22'43 'W 21�h00 i . -I- 1-x-5 N88-17'1 8'E 8' SEWER 31198' J Cj O m tn N -.4 ul r Q Z 0 m F- U a O Z II z Q� U Of J La 3 CU VI U)00r, >- of of a ++ Of N N a_ W1-� HV)V! IIII APPROXIMATE FINISHED L GRADE ® CENTERINE - - - -- - -- - -- - 344 �- INVERT 18" DRAIN ■ INVERT 18" DRAIN '� (~'8" WATER ■ 12 +00 13 +00 14 +00 15 +00 16 +00 17 +00 18 +00 (STA. 12 +19.78 TO 21+15.80) SCALE: 1" = 50' HORIZONTAL SCALE: 1" = 5' VERTICAL LEGEND: ABBREVIATIONS CL CENTERUNE SMH SEWER MANHOLE INV INVERT SCO SEWER CLEANOUT SD STORM DRAIN SDMH STORM DRAIN MANHOLE MH MANHOLE EXIST EXISTING CB CATCH BASIN ELEV ELEVATION JB JUNCTION BOX R/W RIGHT OF WAY SCP STREET CONSTRUCTION PLAN T M. )cI-_ TOP OF MANHOLE/TOP OF CLEANOUT ELEVATION S CONSTRUCT SEWER PER CITY STANDARDS ® CONSTRUCT SEWER MANHOLE TYPE "A" PER C.O.B. STD. S -7. ® CONSTRUCT SEWER CLEANOUT PER C.O.B. STD. S -20. CONSTRUCT STORM DRAIN PER CITY STANDARDS ® CONSTRUCT STORM DRAIN MANHOLE TYPE "A" PER C.O.B. STD. S -7. Itr CONSTRUCT CATCH BASIN TYPE "A" PER C.O.B. STD. S -12. NOTES 1) ALL CATCH BASINS ARE TO BE TYPE "A" NTH 3.5. OPENINGS PER C.O.B. STD. S -12 UNLESS OTHERWISE NOTED. 2) ALL PIPE ELEVATIONS SHOWN ARE INVERT ELEVATIONS UNLESS OTHERWISE NOTED. SECTION 0 ESIGNA110N: SECTION LETTER _2 SHEET WERE SECTION IS SH0 MI INSTALL 319.98 LFOF 8" ® 0.25% 19 +00 20 +00 ■ - SIZE 336 BEARING ' . �___• ' ��� . - INVERT-W-- -SEWER + - N14' 23' 01.05 "E INVERT 8" SEWER Z 17.39 N32' 38' 23.70 'E I I 0 332 w3 I Z < w3 Q . - - - -t- U) .- Z- J 00 00 jj � jj i I '' OJ 0000 I 1 (i I >> i € z ' >> i N ■ Lad ? o � ■ o 'n jE co(o I ; z U•i I z of m cD i Q O �. _ � Sri - - - -- _ _ --- a f- -- -- 6,6 -- -- - _ 8 ■ I n M i 324 V) M rn mW 3 » -- -- f- - _ Q w --I- W W I 1 ' ? I W i H J J 1 VWi (n W W I I (n V) W W I 12 +00 13 +00 14 +00 15 +00 16 +00 17 +00 18 +00 (STA. 12 +19.78 TO 21+15.80) SCALE: 1" = 50' HORIZONTAL SCALE: 1" = 5' VERTICAL LEGEND: ABBREVIATIONS CL CENTERUNE SMH SEWER MANHOLE INV INVERT SCO SEWER CLEANOUT SD STORM DRAIN SDMH STORM DRAIN MANHOLE MH MANHOLE EXIST EXISTING CB CATCH BASIN ELEV ELEVATION JB JUNCTION BOX R/W RIGHT OF WAY SCP STREET CONSTRUCTION PLAN T M. )cI-_ TOP OF MANHOLE/TOP OF CLEANOUT ELEVATION S CONSTRUCT SEWER PER CITY STANDARDS ® CONSTRUCT SEWER MANHOLE TYPE "A" PER C.O.B. STD. S -7. ® CONSTRUCT SEWER CLEANOUT PER C.O.B. STD. S -20. CONSTRUCT STORM DRAIN PER CITY STANDARDS ® CONSTRUCT STORM DRAIN MANHOLE TYPE "A" PER C.O.B. STD. S -7. Itr CONSTRUCT CATCH BASIN TYPE "A" PER C.O.B. STD. S -12. NOTES 1) ALL CATCH BASINS ARE TO BE TYPE "A" NTH 3.5. OPENINGS PER C.O.B. STD. S -12 UNLESS OTHERWISE NOTED. 2) ALL PIPE ELEVATIONS SHOWN ARE INVERT ELEVATIONS UNLESS OTHERWISE NOTED. SECTION 0 ESIGNA110N: SECTION LETTER _2 SHEET WERE SECTION IS SH0 MI INSTALL 319.98 LFOF 8" ® 0.25% 19 +00 20 +00 ■ LINE # SIZE 336 BEARING ■ O 25.71 N14' 23' 01.05 "E ■ Z 17.39 N32' 38' 23.70 'E I 0 332 ■ Z < 3 o■ OR to U 0o + J > N ■ Lad ? 328 � ■ � 'n O 8 ■ W w- 324 mW _ 21+00 TEMPORARY SUMP 7 PER C.O.B. DOC# 0215028734 I I I I 22±00 I I I I 1 11 — — — — — — — — — — I -- I m I SUMP VOLUME REQUIRED: V = E(CXA) X 0.15 V = ((3.10 *0.40)(1.07 *0.15)) *0.15 V = 0.21 AF PROVIDED: V = (110 *60) *1.5 = 0.23 AF SUMP SIZE = BOTTOM 107 X 57 TOP 113 X 63 113' LINE TABLE LINE # SIZE LENGTH BEARING L1 18' 25.71 N14' 23' 01.05 "E L2 18' 17.39 N32' 38' 23.70 'E 107' iA 1� �1 A TEMPORARY SUMP SECTION SCALE: N.T.S. 63' 57' 2 2 B TEMPORARY SUMP SECTION SCALE: N.T.S. SCALE: 1"=50' 25 0 50 100 50 12.5 5 � ��' o P H A 5 r 3 -- - -} — -- F ° I O -- — 1- - — -� - — _ I -- -- I — -- — I -- - — _ . — VOYAGEURS DR. DR. JoilJOpi I-'° I �o I E-o �o �o��o I — I — — — — — — d! -0 0) - Iovi , of J01 Jol JoIJo 1�0 I J°0 �o ro ° °� o'`�' o°'' oM1 0,°.�'lo,°�' IDOi I oil J °I JOI J° I pe) 11 +� 40MO�MO41 ��w42 43Mw 44 �W �W �w �"'� oMl o J I ��1w� 11�-i°n -° n 45 a 46 nR �n: 47 I�,w 48 49 �W 0W 0) 0 o 54 I-J r� r J d I Ki : l (0 ; r i r� , �r i rn u I !n l o �n I o �n I ai �°n I ai �°n I _ o _ o uj I 5 2 M w I 5 vi ;.� I w Q w w I + Z I ± Z I+ O I N Z I w, < (n IN IN I I _ ( I cn 11 +00 -� 12 +00 13 +00 - s s - - -I r — - -I I s r s- 346 342 338 334 330 326 322 d Ico d' N O O O O + ZI �zl �ZItoZ � ' gam- 14 +00 15 +00 s - - �o of �olw° ��O T• Of o Of 0 ON i oNI rn oN 1 M ,o ao �0 !o!o N3 ` 00, oN'° I °oN IOoN --uiaf IoN Imo° I -0 04 C14 I N3 I 0 ZJW I O) p N N 3 I n ^I �!�i rn� , 0)LO 00 wv� 1 0 12 i +039 38 poi 37010036 I X035 ENO 3 °001 0 33 I� (n I N (n En I n ((n N O <00 + 0 i H I Q I I t U) ��� I d} VOl I (n I c~n I ►a- 1� i ! Q ���le m d to �t I LO 0 I� Z I W z I I I N U1I N t[)I I I ca �( o a cOO p I LO n , 04 to Z o + + 0 L Z Z + c, � � I I t - I Z, ,vr u"!0 I w J < l < , I o° :' J v V) E V)Z S5 - -- - -�_ V' Z ' CD LO - -4- N89'12'10 "W -16 +00 - 17 +00 18 +00 19 +00 s � # ---{- S - --+ -- - - i - 89'12'10 E 8 SEYyER 395.00' �— S89'12'10 "E 6° SEWER 110.84' ESTACADA AVENUE (STA. 10 +95.00 TO 19 +70.00) SCALE: 1" = 50' HORIZONTAL 1- p — 0 ub 11 F-- I. I ' o'ol t- 0 0-01 o f -°o F- p lo`o ,o c� o l r-o (I 56 A 5 r � p N' N 0 NI 1 o N I N �ip0'l 61 X00 I Nol cm, C, INo O IN3 Z-i °3 Z�3 0_ 1 1 o 0 1 32 I -- 01 0 u) 31 0 I 0 30 1 .- ,n I N c) 29 I N O I n uj J 28�OO; 0 cn N_ I 27 °� Z> 26 Z� uj 0 (n I } 0I + 0l O I + 0 + <0)m I (0 � wNtn W Ln (n (I) (n (� V) ! 0l Urn + I ' < i I �- I J i a+o W (� '- -�- rQ- W�� I w�I- H a ROXIMATE FINISHED m W r m ESTACADA AVENUE (STA. 10 +95.00 TO 19 +70.00) SCALE: 1" = 50' HORIZONTAL 11+00 12 +00 13 +00 14 +00 15 +00 16 +00 (STA. 10 +95.00 TO 19 +70.00) SCALE: 1" = 50' HORIZONTAL SCALE: 1" = 5' VERTICAL LEGEND: ABBREVIATIONS CL CENTERLINE SMH SEWER MANHOLE INV INVERT SCO SEWER CLEANOUT SD STORM DRAIN SDMH STORM DRAIN MANHOLE MH MANHOLE EXIST EXISTING CB CATCH BASIN ELEV ELEVATION JB JJNC11ON BOX R/W RIGHT OF WAY SCP STREET CONSTRUCTION PLAN T p M, 363.22 TOP OF MANHOLE /TOP OF CLEANOUT ELEVATION S CONSTRUCT SEWER PER CITY STANDARDS G CONSTRUCT SEWER MANHOLE TYPE "A' PER C.O.B. STD. S -7. ® CONSTRUCT SEWER CLEANOUT PER C.O.B. STD. S -20. 17 +00 CONSTRUCT STORM DRAIN PER CITY STANDARDS ® CONSTRUCT STORM DRAIN MANHOLE TYPE "A" PER C.O.B. STD. S -7. -tr CONSTRUCT CATCH BASIN TYPE "A' PER C.O.B. STD, S -12. NOTES 1) ALL CATCH BASINS ARE TO BE TYPE "A" WITH 3.5' OPENINGS PER C.O.B. STD. S -12 UNLESS OTHERWISE NOTED. 2) ALL PIPE ELEVATIONS SHOWN ARE INVERT ELEVATIONS UNLESS OTHERWISE NOTED. SECTION DESIGNATION: SECTION LETTER _2 SHEET WHERE SECTION IS SHOWN 18 +00 19 +00 344 340 336 332 328 324 SCALE: 1 " =50' 25 0 50 100 50 12.5 r m d I ¢V) N - ._. P j' 56 A 5 r � �< o 0 � o� 0 O Z 00 C� cr- d APP OXIMATE FINISHED cn H---- - - - - - - ° O Z w z I Q J o I J Q �. W W U I co GRADE ® CENTERLINE J J i W (� (n (� 0 V) H a ROXIMATE FINISHED m W r m 0 Y x W Y a W Jt II II m O U 11+00 12 +00 13 +00 14 +00 15 +00 16 +00 (STA. 10 +95.00 TO 19 +70.00) SCALE: 1" = 50' HORIZONTAL SCALE: 1" = 5' VERTICAL LEGEND: ABBREVIATIONS CL CENTERLINE SMH SEWER MANHOLE INV INVERT SCO SEWER CLEANOUT SD STORM DRAIN SDMH STORM DRAIN MANHOLE MH MANHOLE EXIST EXISTING CB CATCH BASIN ELEV ELEVATION JB JJNC11ON BOX R/W RIGHT OF WAY SCP STREET CONSTRUCTION PLAN T p M, 363.22 TOP OF MANHOLE /TOP OF CLEANOUT ELEVATION S CONSTRUCT SEWER PER CITY STANDARDS G CONSTRUCT SEWER MANHOLE TYPE "A' PER C.O.B. STD. S -7. ® CONSTRUCT SEWER CLEANOUT PER C.O.B. STD. S -20. 17 +00 CONSTRUCT STORM DRAIN PER CITY STANDARDS ® CONSTRUCT STORM DRAIN MANHOLE TYPE "A" PER C.O.B. STD. S -7. -tr CONSTRUCT CATCH BASIN TYPE "A' PER C.O.B. STD, S -12. NOTES 1) ALL CATCH BASINS ARE TO BE TYPE "A" WITH 3.5' OPENINGS PER C.O.B. STD. S -12 UNLESS OTHERWISE NOTED. 2) ALL PIPE ELEVATIONS SHOWN ARE INVERT ELEVATIONS UNLESS OTHERWISE NOTED. SECTION DESIGNATION: SECTION LETTER _2 SHEET WHERE SECTION IS SHOWN 18 +00 19 +00 344 340 336 332 328 324 SCALE: 1 " =50' 25 0 50 100 50 12.5 r m N - ._. P j' Z 0 APP OXIMATE FINISHED cn 3 W GRADE ® CENTERLINE i H a ROXIMATE FINISHED 0 +GBAQE -- a rFNTP RI INF 6 G i 8" 1AATJ . INVERT 8" SE R F-: _ NV ,, RT co C i IN w 3 RT 6" EWER Z (� - WER 1 O ° Z. -00 00 W ZZ J ZZ LO + JU 0 O C3 Op 200 Mr_ Z� QOOiCi OD M N �� wN» ( to to En V) w 3�ww Z J Q W W (n W W w 1 N (n W w Q -- a. INSTALL 395.00 LF OF 8" SEWER 0.35% INSTALL 11U.64 SEWER LF OF a 1 I .00% P T-I 11+00 12 +00 13 +00 14 +00 15 +00 16 +00 (STA. 10 +95.00 TO 19 +70.00) SCALE: 1" = 50' HORIZONTAL SCALE: 1" = 5' VERTICAL LEGEND: ABBREVIATIONS CL CENTERLINE SMH SEWER MANHOLE INV INVERT SCO SEWER CLEANOUT SD STORM DRAIN SDMH STORM DRAIN MANHOLE MH MANHOLE EXIST EXISTING CB CATCH BASIN ELEV ELEVATION JB JJNC11ON BOX R/W RIGHT OF WAY SCP STREET CONSTRUCTION PLAN T p M, 363.22 TOP OF MANHOLE /TOP OF CLEANOUT ELEVATION S CONSTRUCT SEWER PER CITY STANDARDS G CONSTRUCT SEWER MANHOLE TYPE "A' PER C.O.B. STD. S -7. ® CONSTRUCT SEWER CLEANOUT PER C.O.B. STD. S -20. 17 +00 CONSTRUCT STORM DRAIN PER CITY STANDARDS ® CONSTRUCT STORM DRAIN MANHOLE TYPE "A" PER C.O.B. STD. S -7. -tr CONSTRUCT CATCH BASIN TYPE "A' PER C.O.B. STD, S -12. NOTES 1) ALL CATCH BASINS ARE TO BE TYPE "A" WITH 3.5' OPENINGS PER C.O.B. STD. S -12 UNLESS OTHERWISE NOTED. 2) ALL PIPE ELEVATIONS SHOWN ARE INVERT ELEVATIONS UNLESS OTHERWISE NOTED. SECTION DESIGNATION: SECTION LETTER _2 SHEET WHERE SECTION IS SHOWN 18 +00 19 +00 344 340 336 332 328 324 SCALE: 1 " =50' 25 0 50 100 50 12.5 r m N Z 0 cn W 0= H a 0 VOYAGEURS DR. SEE RIGHT 0 -� O p � 58 o0o po 0 1 p "' 1 O zou) -T 24 25 co 0 L025Jq,. 1 , `n o r` Z v cO 1 - I r Q N+ 0 Hoorn W 7,1 59 N V)- I Q 1 V) I o ¢ o I -- - - - - -- -- - r` �---- - - - - o ° I )0 `n z 18 +00 19 +00 6 0 5 - - -+— - - +N89'12'10 "W— --I - 9lZ10'E 8 SEWER 3 00' f M, 342 338 334 330 326 322 COOPER LAKE AVENUE (STA. 18 +15.00 TO 19 +70.00) SCALE: 1" = 50' HORIZONTAL DR. AVE. I ROXIMATE FINIS ® ENTER LLJ LEFT - -- -- -- -- -- -- F -- I > �- �' -- - -- S0� I co 1 zow '� I �o 10 Z< w o I , O i o r-> + N O �� 61 U�+ �o I -� 53 V cr `` O° u UJ I + 'O �0 °N � 22 1 21 Y 27 26 Ld o0 O N 22N W o0 Z 5.00' 8" WA R-,) 1 I I U I rn Z Qrn v� O � _ C" Q to tn { - - + p U I 00 A N N ° orll� I ° I 1 O O ' + W n t'1 F- '� F- I c ' I V, ++ 62 -- �- -_—j -_ - -� -- --< G INVERT " SEWER--' II t� (n co FE O M, 342 338 334 330 326 322 COOPER LAKE AVENUE (STA. 18 +15.00 TO 19 +70.00) SCALE: 1" = 50' HORIZONTAL 18 +00� 19 +00 (STA. 18 +15.00 TO 19 +70.00) SCALE: 1" = 50' HORIZONTAL SCALE: 1" = 5' VERTICAL 348 344 340 336 332 328 324 320 20 +00 SCALE: 1"=50' 346 342 338 334 330 326 322 FORT SANDERS DR. AVE. I ROXIMATE FINIS ® ENTER SEE LEFT ZO II 4.i > I I AP GRADE ED NE N 20 0�3 23 � S0� I 1 zow '� I �o U + Sri co - - - - +�- - - Z< La Z Z I W=n I ?Qw -< -- r) -_ __ W J N O �� a- 00-- U�+ �o I -� 53 V JU `` O° I UJ I + 'O �0 O U u Lj I 22 1 21 °U) F- w N o0 �� + I Z 5.00' 8" WA R-,) 1 I I U I rn Z Qrn v� I � _ C" Q to tn { o- I � N 00 V A N N M I ° I 1 I I N �� N MF- N In F- 3�1 TRACT BOUNDARY STA. 21 +15.80 C.L. G INVERT " SEWER--' t� co FE O Z v Qcl) _ --- _._V_. --M Z O Z to 00 co 00 J� A li ui .1. 0D N W ul Z V W ccQa < cr � < Q � J ? ? O O Z o. M O Q c0 rn in M M 0_ r w 3aWww W H J J J (n(nwWW - , — Z�� I 150.00 LF OF 8" CAD 0.25% W J W 'r N od U) < S °D CID W W i♦♦/—� Z v/ INSTALL Z ; a 18 +00� 19 +00 (STA. 18 +15.00 TO 19 +70.00) SCALE: 1" = 50' HORIZONTAL SCALE: 1" = 5' VERTICAL 348 344 340 336 332 328 324 320 20 +00 SCALE: 1"=50' 346 342 338 334 330 326 322 FORT SANDERS DR. AVE. SEE SHEET 3 SEE LEFT ZO II 4.i > I I I Wok N 20 0�3 23 � Y � I 1 zow '� I �o U + Sri co - - - - +�- - - Z< La Z Z I W=n I ?Qw -< -- r) -_ __ W J N O �� a- 00-- U�+ �o I -� 53 V JU `` O° I UJ I + 'O �0 O U u Lj I 22 1 21 °U) F- w N o0 �� + I Z 5.00' N 06 � I I U I rn Z Qrn v� I � _ C" Q COOPER LAKE AVE. AVE. 4 SEE LEFT ZWVQ N -�,�; � I Qyo I Z 11 N 20 0�3 23 � Y � I �oQ 1 zow '� I I _ Z Q F U + Sri co - - - - +�- - - r O •tn I Z I W=n I ?Qw -< -- r) -_ __ W J N O �� a- 00-- U�+ O Q I -� 53 V JU ' r7 I O r7 I I Q 'O �0 V' u Lj I 22 1 21 O F- w N U) �� +° a I Z 5.00' N 06 � I Z aQ 04 I ° p � � _ C" Q to tn N O 11+00 z co LLl °' I >M I I ° g i z +�T u 13 +00 S 00'47'50'W 6' SEWER I Oz 24 0 27 cr�Q I J p ESTACADA II > I I I' SEE SHEET W I � w' 3 AVE. 4 3� j I cr.�llw I I z�� I w 52 I F J-J A 5 r - CU , ZWVQ N -�,�; 1 Qyo I 0-'o N - - - - 'ao' - - �N 3 , F H A I D °r o I >J .N- Q co � p I _ Z Q F U + Sri co - - - - +�- - - r � o°� z I I o- W o � H co rn I 25 N O �� O F-�I OI I � I I -� 53 V m m r7 I O r7 I LLJ I 2 O V' aotA 0) Lj O F- w t~n V) L1J I a 04 06 � X�62 59 )0'47 50 E 8 SEWER _ 14 +00 I- — N00'47'50 "EI- - — o N ro M ro U.- J J T p 1s��321 I i 00 I N r t0 I O 1 w Q F-�I OI ft O m m r7 I O r7 I W 2 O aotA 0) Lj O O �°60^ O Z 3: 0 w X 04 06 � X�62 59 Z 00 + 04 I ° p � � _ C" Q to tn N O o- I � N 00 V A N N M I ° I 1 I I N �� N MF- N In F- 3�1 TRACT BOUNDARY STA. 21 +15.80 C.L. I S1 -t-- +-N- - -� -- � l 1.�rO X O I. -:"o 1-O H oi ai O QY o 1 x O -0 �W (W (� °� W 58 N ro N N 57 1 56 ' ° 55 ' 3 54 n N CN �� �N +00 I 1 � I '- Q z NI I I VOYAGEURS DRIVE (STA. 10 +00.00 TO 16 +45.72) SCALE: 1" = 50' HORIZONTAL SCALE: 1"=50' 9 +50 10 +00 11+00 12 +00 13 +00 14 +00 (STA. 10 +00.00 TO 16 +45.72) SCALE: 1" = 50' HORIZONTAL SCALE: 1" = 5' VERTICAL LEGEND: ABBREVIATIONS CL CENTERLINE SMH SEWER MANHOLE INV INVERT SCO SEWER CLEANOUT SD STORM DRAIN SDMH STORM DRAIN MANHOLE MH MANHOLE EXIST EXISTING CB CATCH BASIN ELEV ELEVATION JB JUNCTION BOX R/W RIGHT OF WAY SCP STREET CONSTRUCTION PLAN T.O.M. 363.22 TOP OF MANHOLE /TOP OF CLEANOUT ELEVATION —s —CONSTRUCT SEWER PER CITY STANDARDS ® CONSTRUCT SEWER MANHOLE TYPE "A' PER C.O.B. STD. S -7. ® CONSTRUCT SEWER CLEANOUT PER C.O.B. STD. S -20. CONSTRUCT STORM DRAIN PER CITY STANDARDS ® CONSTRUCT STORM DRAIN MANHOLE TYPE "A" PER C.O.B. STD. S -7. CONSTRUCT CATCH BASIN TYPE 'A" PER C.O.B. STD. S -12. NOTES 1) ALL CATCH BASINS ARE TO BE TYPE "A" WITH 3.5' OPENINGS PER C.O.B. STD. S -12 UNLESS OTHERWISE NOTED. 2) ALL PIPE ELEVATIONS SHOWN ARE INVERT ELEVATIONS UNLESS OTHERWISE NOTED. SECTION DESIGNATION: SECTION LETTER _2 SHEET WHERE SECTION IS SHOWN 15 +00 16 +00 ' 348 344 340 336 332 328 324 320 25 0 50 100 50 12.5 a N ro M ro U.- J J O n p 1s��321 I w Q m m Z 0 ATE FINISHED W o- GRADE ® CENTERLINE 3�1 G t� co FE Z v Qcl) J J� A li _ X N W ul Z V W ccQa < cr � a Q � W 'r N od °D CID W W i♦♦/—� Z v/ Z ; a O "ZLLJ < Q ,e ]C Ix H N a J In `W 3 WN °o W CL'o �/� O0 VJ o O' U< a OD W W I I Lo N LL 0 �8- ATER Qcn oLo INVERT 8' SEWER—Z O M D:z :r Z O Q Z. 00 cn J cD M r- W u+ fl) - -J b > j ,y --- N � W N WF- J r.,) O cn cn w W - � (W j- W z o M + N MMr •- W W ~ 1d- J J W fn (n WwW Z INSTALL 113.18 INSTALL 359.99 LF OF 8" SEWER J LF OF 6" SEWE 0 1.007 0 1.007 < = i I I 9 +50 10 +00 11+00 12 +00 13 +00 14 +00 (STA. 10 +00.00 TO 16 +45.72) SCALE: 1" = 50' HORIZONTAL SCALE: 1" = 5' VERTICAL LEGEND: ABBREVIATIONS CL CENTERLINE SMH SEWER MANHOLE INV INVERT SCO SEWER CLEANOUT SD STORM DRAIN SDMH STORM DRAIN MANHOLE MH MANHOLE EXIST EXISTING CB CATCH BASIN ELEV ELEVATION JB JUNCTION BOX R/W RIGHT OF WAY SCP STREET CONSTRUCTION PLAN T.O.M. 363.22 TOP OF MANHOLE /TOP OF CLEANOUT ELEVATION —s —CONSTRUCT SEWER PER CITY STANDARDS ® CONSTRUCT SEWER MANHOLE TYPE "A' PER C.O.B. STD. S -7. ® CONSTRUCT SEWER CLEANOUT PER C.O.B. STD. S -20. CONSTRUCT STORM DRAIN PER CITY STANDARDS ® CONSTRUCT STORM DRAIN MANHOLE TYPE "A" PER C.O.B. STD. S -7. CONSTRUCT CATCH BASIN TYPE 'A" PER C.O.B. STD. S -12. NOTES 1) ALL CATCH BASINS ARE TO BE TYPE "A" WITH 3.5' OPENINGS PER C.O.B. STD. S -12 UNLESS OTHERWISE NOTED. 2) ALL PIPE ELEVATIONS SHOWN ARE INVERT ELEVATIONS UNLESS OTHERWISE NOTED. SECTION DESIGNATION: SECTION LETTER _2 SHEET WHERE SECTION IS SHOWN 15 +00 16 +00 ' 348 344 340 336 332 328 324 320 25 0 50 100 50 12.5 a N ro M ro U.- J J O n p 1s��321 I w Q m m Z 0 W o- 0 LLf co FE Z v Qcl) J J� A li _ X N W ul Z V W ccQa < cr � a Q � W 'r N od °D CID W W i♦♦/—� Z v/ Z ; a O "ZLLJ < Q ,e ]C Ix H N a J In `W 3 WN °o W CL'o �/� O0 VJ o O' U< a OD W W I I Lo N LL 0