Loading...
HomeMy WebLinkAboutFMC RESULTS 2015IMPACT VALVE LEAK DETECTOR MONITOR CERTIFICATION SPILL BUCKET TEST 11000 N. MoPac Expressway, Suite 500 Austin, Texas 78759 Phone: (512) 451-6334 Fax: (512) 459-1459 Date Printed and Mailed: 1/6/2016 BAKERSFIELD FIRE DEPARTMENT OFFICE OF ENVIRONMENTAL SERVICES INSPECTOR ERNIE MEDINA 1501 TRUXTUN AVE. BAKERSFIELD, CA 93301 Test Date: 12/22/2015 Order Number: 3428592 Dear Regulator, Enclosed are the results of recent testing performed at the following facility: 7-ELEVEN #16329, MKT 2368 1701 PACHECO ROAD BAKERSFIELD, CA 93307 Testing performed: Sincerely, Dawn Kohlmeyer Manager, Field Reporting LDT 5000 Field Test Apparatus Line Leak Detector Test Page 1 of 1 Work Order:3428592 Date:12/22/2015 Site Name / ID:7-ELEVEN #16329, MKT 2368 / 16329 Address:1701 PACHECO ROAD City:BAKERSFIELD State:CA Zip:93307 Tank ID Product Product Line Tested From Existing/New Mechanical/Electronic Manufacturer/Model Serial No. Pump Operating Pressure (psi) Calibrated Leak (ml/min) Calibrated Leak (gph) Holding PSI *N/A for Electronic LD's Resiliency (ml) *N/A for Electronic LD's Metering PSI *N/A for Electronic LD's Opening Time (sec) *N/A for Electronic LD's Test Results T2 RUL MAIN RUL 1 1 Existing Electronic Veeder Root PLLD 152567 26.00 189.0 3.00 26.00 Pass T3 PUL PUL 1 1 Existing Electronic Veeder Root PLLD 108123 27.00 189.0 3.00 27.00 Pass Technician Comments: Technician Name:Arturo Gutierrez Certification #:1306 Technician Signature:Expire Date:11/3/2016 Environmental Compliance for Petroleum Systems © 2016 Tanknology Inc., Austin, TX.    All rights reserved.    tanknology.com Impact Valve Inspection Impact Valve Operational Inspection Work Order:3428592 Date:12/22/2015 Site Name/ID:7-ELEVEN #16329, MKT 2368 Address:1701 PACHECO ROAD City:BAKERSFIELD State:CA Zip:93307 Dispenser Number Grade Secure Mount? Valve Lock?Pass/ Fail Comments 1/2 87 Pass Fail Not Tested 1/2 91 Pass Fail Not Tested 3/4 87 Pass Fail Not Tested 3/4 91 Pass Fail Not Tested Technician Comments: Technician Name:Arturo Gutierrez Signature: Environmental Compliance for Petroleum Systems ©2016 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com Appendix VI (Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at http://www.swrcb.ca.gov.) MONITORING SYSTEM CERTIFICATION For Use By All Jurisdictions Within the State of California Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. A. General Information Facility Name:7-ELEVEN #16329, MKT 2368 Bldg. No.: Site Address:1701 PACHECO ROAD City:BAKERSFIELD Zip:93307 Facility Contact Person:Aman 6/22/15 Contact Phone No.:661-379-5911 Make/Model of Monitoring System:Veeder Root TLS 350 Date of Testing/Servicing:12/22/2015 B. Inventory of Equipment Tested/Certified Check the appropriate boxes to indicate specific equipment inspected/serviced: Tank ID:T1 RUL SIPHON - RUL 2 In-Tank Gauging Probe.Model:Mag 1 Annular Space or Vault Sensor.Model:VR 420 Piping Sump / Trench Sensor(s).Model:VR 208 Fill Sump Sensor(s).Model: Mechanical Line Leak Detector.Model: Electronic Line Leak Detector.Model: Tank Overfill / High-Level Sensor.Model:EXTERNAL Other (specify equipment type and model in Section E on Page 2). Tank ID:T2 RUL MAIN - RUL In-Tank Gauging Probe.Model:Mag 1 Annular Space or Vault Sensor.Model:VR 420 Piping Sump / Trench Sensor(s).Model:VR 208 Fill Sump Sensor(s).Model: Mechanical Line Leak Detector.Model: Electronic Line Leak Detector.Model:Veeder Root PLLD Tank Overfill / High-Level Sensor.Model:EXTERNAL Other (specify equipment type and model in Section E on Page 2). Tank ID:T3 PUL - PUL In-Tank Gauging Probe.Model:Mag 1 Annular Space or Vault Sensor.Model:VR 344 Piping Sump / Trench Sensor(s).Model:vr 208 Fill Sump Sensor(s).Model: Mechanical Line Leak Detector.Model: Electronic Line Leak Detector.Model:Veeder Root PLLD Tank Overfill / High-Level Sensor.Model:EXTERNAL Other (specify equipment type and model in Section E on Page 2). Tank ID: In-Tank Gauging Probe.Model: Annular Space or Vault Sensor.Model: Piping Sump / Trench Sensor(s).Model: Fill Sump Sensor(s).Model: Mechanical Line Leak Detector.Model: Electronic Line Leak Detector.Model: Tank Overfill / High-Level Sensor.Model: Other (specify equipment type and model in Section E on Page 2). Dispenser ID:1/2 Dispenser Containment Sensor(s).Model:VR 352 Shear Valve(s). Dispenser Containment Float(s) and Chain(s). Dispenser ID:3/4 Dispenser Containment Sensor(s).Model:VR 322 Shear Valve(s). Dispenser Containment Float(s) and Chain(s). Dispenser ID: Dispenser Containment Sensor(s).Model: Shear Valve(s). Dispenser Containment Float(s) and Chain(s). Dispenser ID: Dispenser Containment Sensor(s).Model: Shear Valve(s). Dispenser Containment Float(s) and Chain(s). Dispenser ID: Dispenser Containment Sensor(s).Model: Shear Valve(s). Dispenser Containment Float(s) and Chain(s). Dispenser ID: Dispenser Containment Sensor(s).Model: Shear Valve(s). Dispenser Containment Float(s) and Chain(s). *If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. C. Certification- I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers’ guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a copy of the report; (check all that apply): System set- up Alarm history report Technician Name (print):Arturo Gutierrez Signature: Certification No.: A24526 License. No.:743160 Class 'A' Testing Company Name:Tanknology Phone No.:(800) 800-4633 Testing Company Address:11000 N. MoPac Expressway Suite 500 Date of Testing/Servicing:12/22/2015 Monitoring System Certification Page 1 of 3 12/07 D. Results of Testing/Servicing Software Version Installed:329.02 Complete the following checklist: Yes No*Is the audible alarm operational? Yes No*Is the visual alarm operational? Yes No*Were all sensors visually inspected, functionally tested, and confirmed operational? Yes No*Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere with their proper operation? Yes No* N/A If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) operational? Yes No* N/A For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate positive shut-down? (Check all that apply) Sump/Trench Sensors; Dispenser Containment Sensors. Did you confirm positive shut-down due to leaks and sensor failure/disconnection? Yes; No Yes No* N/A For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank fill point(s) and operating properly? If so, at what percent of tank capacity does the alarm trigger? 90% Yes* No Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced and list the manufacturer name and model for all replacement parts in Section E, below. Yes* No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) Product; Water. If yes, describe causes in Section E, below. Yes No*Was monitoring system set-up reviewed to ensure proper settings? Attach set up reports, if applicable Yes No*Is all monitoring equipment operational per manufacturer's specifications? * In Section E below, describe how and when these deficiencies were or will be corrected. E. Comments: T2 -87 main piping sump sensor. VR 208. Tested faisafe, ESO and all sensors for proper function. Replaced lightbulb on external alarm. Monitoring System Certification Page 2 of 3 12/07 F. In-Tank Gauging / SIR Equipment: Check this box if tank gauging is used only for inventory control. Check this box if no tank gauging or SIR equipment is installed. This section must be completed if in-tank gauging equipment is used to perform leak detection monitoring. Complete the following checklist: Yes No*Has all input wiring been inspected for proper entry and termination, including testing for ground faults? Yes No*Were all tank gauging probes visually inspected for damage and residue buildup? Yes No*Was accuracy of system product level readings tested? Yes No*Was accuracy of system water level readings tested? Yes No*Were all probes reinstalled properly? Yes No*Were all items on the equipment manufacturer's maintenance checklist completed? * In the Section H, below, describe how and when these deficiencies were or will be corrected. G. Line Leak Detectors (LLD): Check this box if LLDs are not installed. Complete the following checklist: Yes No* N/A For equipment start-up or annual equipment certification, was a leak simulated to verify LLD performance? (Check all that apply) Simulated leak rate: 3 g.p.h.; 0.1 g.p.h; 0.2 g.p.h. Yes No*Were all LLDs confirmed operational and accurate within regulatory requirements? Yes No*Was the testing apparatus properly calibrated? Yes No* N/A For mechanical LLDs, does the LLD restrict product flow if it detects a leak? Yes No* N/A For electronic LLDs, does the turbine automatically shut off if the LLD detects a leak? Yes No* N/A For electronic LLDs that are programmed for positive shut down, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? Yes No* N/A For electronic LLDs that are programmed for positive shut down, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a test? Yes No* N/A For electronic LLDs, have all accessible wiring connections been visually inspected? Yes No*Were all items on the equipment manufacturer's maintenance checklist completed? * In the Section H, below, describe how and when these deficiencies were or will be corrected. H.Comments: Passed. Page 3 of 3 12/07 SWRCB, January 2006 Spill Bucket Testing Report Form This form is intended for use by contractors performing annual testing of UST spill containment structures. The completed form and printouts from tests (if applicable), should be provided to the facility owner/operator for submittal to the local regulatory agency. 1. FACILITY INFORMATION Facility Name: 7-ELEVEN #16329, MKT 2368 Date of Testing: 12/22/2015 Facility Address: 1701 PACHECO ROAD , BAKERSFIELD, CA 93307 Facility Contact: Aman 6/22/15 Phone: 661-379-5911 Date Local Agency Was Notified of Testing: 12/18/2015 Name of Local Agency Inspector (if present during testing): Kris Karns 2. TESTING CONTRACTOR INFORMATION Company Name: TANKNOLOGY INC. Technician Conducting Test: Arturo Gutierrez Credentials1: CSLB Contractor ICC Service Tech. SWRCB Tank Tester Other (Specify) License Number(s): 743160 3. SPILL BUCKET TESTING INFORMATION Test Method Used By: Hydrostatic Vacuum Other Test Equipment Used: LAKE TEST Equipment Resolution: 0.0625 in. Identify Spill Bucket (By Tank Number, Stored Product, etc.) Bucket Installation Type: Bucket Diameter: Bucket Depth: Wait time between applying vacuum/water and start of test Test Start Time (TI): Initial Reading (RI): Test End Time(TF): Final Reading (RF): Test Duration(TF–TI): Change in Reading (RF–RI) : Pass/Fail Threshold or Criteria: Test Result: Spill Box # Tank T1 RUL SIPHON RUL 2 - Fill 1 - Direct - Grade level Direct Bury Contained in Sump 11.00 12.00 15 min 10:00:00 11.1750 in. 11:00:00 11.1750 in. 1 0.00 in. +/- 0.00 Pass Spill Box # Tank T2 RUL MAIN RUL - Fill 1 - Direct - Grade level Direct Bury Contained in Sump 11.00 12.00 15 min 10:00:00 10.8750 in. 11:00:00 10.8750 in. 1 hr 0.00 in. +/- 0.00 Pass Spill Box # Tank T3 PUL PUL - Fill 1 - Direct - Grade level Direct Bury Contained in Sump 11.00 12.00 15 min 10:00:00 11.00 in. 11:00:00 11.00 in. 1 hr 0.00 in. +/- 0.00 Pass Spill Box # Direct Bury Contained in Sump min +/- Comments - (include information on repairs made prior to testing, and recommended follow-up for failed tests) CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING I hereby certify that all the information contained in this report is true, accurate, and in full compliance with legal requirements. Technician's Signature:Date:12/22/2015 1State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements may be more stringent. WO: 3428592 Inspector Kris Karns okay with hydrostatic testing today. 7-Eleven Test Water Log Work Order: Site Name/ID: Address: City: 3428592 7-ELEVEN #16329, MKT 2368 1701 PACHECO ROAD BAKERSFIELD Date: 12/22/2015 State: CA Zip: 93307 Work Performed:ATG, E-Stop, Impv, LDs, SB's Was Test Water left on site? Yes Test Fluid Transported Off Site by Tanknology Transported off Site by Other Company No Water used If Yes describe how much water and how contained?10 gallons on 2 five gallon bucket. If Yes who and when did you contact from site to report the water? Called Michelle from site at 1:00 pm. If Transported Off Site by Tanknology how much was hauled? If Transported Off Site by Other Company what company and how much water? Technician Signature: Date: 12/22/2015 WO: 3428592 Site Diagram (This site diagram is for reference only and is not drawn to scale) Work Order:3428592 Site ID / Name:16329 / 7-ELEVEN #16329, MKT 2368 Address:1701 PACHECO ROAD City:BAKERSFIELD State:CA Zip:93307 W.O.# SC1-3428592 Parts Log W.O.# SC1-3428592 I10100 DEC 22, 2015 1:24 PM 235038 7-11 16329 1701 PACHECO RD BAKERSFIELD CA 93304 B0383134105001 SYSTEM STATUS REPORT D 5:AUTODIAL FAILURE D 5:ALARM CLEAR WARNING D 5:DELIVERY REPORT WRN I50301 DEC 22, 2015 1:25 PM # 1:235038 7-11 16329 I50302 DEC 22, 2015 1:25 PM # 2:1701 PACHECO RD I50303 DEC 22, 2015 1:25 PM # 3:BAKERSFIELD CA 93304 I50304 DEC 22, 2015 1:25 PM # 4:B0383134105001 I51700 DEC 22, 2015 1:25 PM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM I50F00 DEC 22, 2015 1:25 PM MON DD YYYY HH:MM:SS xM I60100 DEC 22, 2015 1:25 PM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 RUL SIPHON ON 2 RUL MAIN ON 3 PUL ON 4 OFF I60200 DEC 22, 2015 1:25 PM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 RUL SIPHON 2 RUL MAIN 3 PUL 4 I60300 DEC 22, 2015 1:25 PM TANK PRODUCT CODE TANK PRODUCT LABEL 1 RUL SIPHON 1 2 RUL MAIN 2 3 PUL 3 4 4 I60400 DEC 22, 2015 1:25 PM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 RUL SIPHON 9897 2 RUL MAIN 9897 3 PUL 9600 4 0 I60700 DEC 22, 2015 1:25 PM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 RUL SIPHON 105.00 2 RUL MAIN 105.00 3 PUL 109.00 4 0.00 I60900 DEC 22, 2015 1:25 PM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 RUL SIPHON 0.000700 2 RUL MAIN 0.000700 3 PUL 0.000700 4 0.000000 I61200 DEC 22, 2015 1:25 PM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 RUL SIPHON 2 NONE 2 RUL MAIN 1 NONE 3 PUL NONE NONE 4 NONE NONE I62100 DEC 22, 2015 1:25 PM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 RUL SIPHON 900 2 RUL MAIN 900 3 PUL 900 4 0 I62200 DEC 22, 2015 1:25 PM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 RUL SIPHON 9120 2 RUL MAIN 9120 3 PUL 9120 4 0 I62300 DEC 22, 2015 1:25 PM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 RUL SIPHON 8640 2 RUL MAIN 8640 3 PUL 8640 4 0 I62400 DEC 22, 2015 1:25 PM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 RUL SIPHON 1.0 2 RUL MAIN 1.0 3 PUL 1.0 I62800 DEC 22, 2015 1:25 PM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 RUL SIPHON 9600 2 RUL MAIN 9600 3 PUL 9600 4 0 I62900 DEC 22, 2015 1:25 PM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 RUL SIPHON 1484 2 RUL MAIN 1484 3 PUL 1440 4 0 I70300 DEC 22, 2015 1:25 PM LIQUID TYPE SENSOR LOCATION TYPE 1 RUL STP PIPING SUMP TRI-STATE (SINGLE FLOAT) 2 TRI-STATE (SINGLE FLOAT) 3 RUL PIPING SUMP DUAL FLT. DISCRIMINATING 4 PUL STP SUMP TRI-STATE (SINGLE FLOAT) 5 RUL SIPHON ANN TRI-STATE (SINGLE FLOAT) 6 RUL MAIN ANN TRI-STATE (SINGLE FLOAT) 7 PUL ANN NORMALLY CLOSED 8 DISP 1-2 DUAL FLT. HIGH VAPOR 9 DISP 3-4 DUAL FLT. HIGH VAPOR 10 RUL MAIN STP SUMP TRI-STATE (SINGLE FLOAT) 11 REG PIPING SVMP TRI-STATE (SINGLE FLOAT) 12 TRI-STATE (SINGLE FLOAT) 13 TRI-STATE (SINGLE FLOAT) 14 TRI-STATE (SINGLE FLOAT) 15 TRI-STATE (SINGLE FLOAT) 16 TRI-STATE (SINGLE FLOAT) I74300 DEC 22, 2015 1:25 PM 2 WIRE CL TYPE SENSOR LOCATION TYPE 1 PREMIUM ANNULAR ULTRA 2 2 ULTRA 2 3 ULTRA 2 4 ULTRA 2 5 ULTRA 2 6 ULTRA 2 7 ULTRA 2 8 ULTRA 2 I78500 DEC 22, 2015 1:26 PM PRESSURE LINE LEAK TANK NUMBER LINE TANK NUMBER Q 1:RUL 2 Q 2:PUL 3 Q 3: NONE I90200 DEC 22, 2015 1:26 PM SOFTWARE REVISION LEVEL VERSION 329.02 SOFTWARE# 346329-100-C CREATED - 09.07.01.16.29 S-MODULE# 330160-160-A SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS BIR PLLD 0.10 AUTO 0.20 REPETITIV WPLLD 0.10 AUTO 0.20 REPETITIV I20600 DEC 22, 2015 1:26 PM 235038 7-11 16329 1701 PACHECO RD BAKERSFIELD CA 93304 B0383134105001 TANK ALARM HISTORY TANK 1 RUL SIPHON HIGH WATER ALARM DEC 22, 2015 11:31 AM DEC 9, 2014 11:50 AM OVERFILL ALARM DEC 22, 2015 11:46 AM SEP 7, 2015 9:01 PM JUL 3, 2015 10:31 AM LOW PRODUCT ALARM DEC 22, 2015 11:28 AM SUDDEN LOSS ALARM APR 20, 2015 9:09 AM FEB 17, 2015 9:57 AM FEB 17, 2015 9:51 AM HIGH PRODUCT ALARM DEC 22, 2015 11:47 AM DEC 9, 2014 12:01 PM INVALID FUEL LEVEL DEC 22, 2015 11:28 AM PROBE OUT DEC 22, 2015 11:50 AM DEC 22, 2015 11:27 AM DEC 9, 2014 12:05 PM HIGH WATER WARNING DEC 22, 2015 11:31 AM DEC 9, 2014 11:50 AM DELIVERY NEEDED DEC 22, 2015 11:28 AM DEC 15, 2015 2:45 PM MAX PRODUCT ALARM DEC 9, 2014 12:01 PM LOW TEMP WARNING DEC 9, 2014 12:06 PM TANK 2 RUL MAIN HIGH WATER ALARM DEC 22, 2015 11:31 AM DEC 9, 2014 11:50 AM OVERFILL ALARM DEC 22, 2015 11:41 AM SEP 7, 2015 9:08 PM JUL 3, 2015 10:38 AM LOW PRODUCT ALARM DEC 22, 2015 11:27 AM SUDDEN LOSS ALARM APR 20, 2015 9:09 AM FEB 17, 2015 9:57 AM FEB 17, 2015 9:51 AM HIGH PRODUCT ALARM DEC 22, 2015 11:41 AM DEC 9, 2014 11:55 AM INVALID FUEL LEVEL DEC 22, 2015 11:27 AM DEC 9, 2014 11:47 AM PROBE OUT DEC 22, 2015 11:46 AM DEC 22, 2015 11:25 AM DEC 9, 2014 11:56 AM HIGH WATER WARNING DEC 22, 2015 11:31 AM DEC 9, 2014 11:50 AM DELIVERY NEEDED DEC 22, 2015 11:27 AM DEC 9, 2014 11:47 AM MAX PRODUCT ALARM DEC 9, 2014 11:55 AM LOW TEMP WARNING DEC 9, 2014 11:58 AM TANK 3 PUL HIGH WATER ALARM DEC 22, 2015 11:38 AM OVERFILL ALARM DEC 22, 2015 11:29 AM DEC 9, 2014 11:47 AM LOW PRODUCT ALARM DEC 22, 2015 11:25 AM SUDDEN LOSS ALARM DEC 22, 2015 11:24 AM OCT 11, 2015 4:56 PM SEP 7, 2015 8:42 PM HIGH PRODUCT ALARM DEC 22, 2015 11:29 AM DEC 9, 2014 11:47 AM INVALID FUEL LEVEL DEC 22, 2015 11:25 AM PROBE OUT DEC 22, 2015 11:40 AM DEC 22, 2015 11:25 AM DEC 9, 2014 11:51 AM HIGH WATER WARNING DEC 22, 2015 11:38 AM DELIVERY NEEDED DEC 22, 2015 11:24 AM MAX PRODUCT ALARM DEC 22, 2015 11:29 AM DEC 9, 2014 11:49 AM LOW TEMP WARNING DEC 22, 2015 11:40 AM I30200 DEC 22, 2015 1:27 PM 235038 7-11 16329 1701 PACHECO RD BAKERSFIELD CA 93304 B0383134105001 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 RUL STP PIPING SUMP DEC 22, 2015 10:35 AM SENSOR OUT ALARM DEC 22, 2015 10:20 AM FUEL ALARM SEP 15, 2015 10:04 AM SETUP DATA WARNING 4 PUL STP SUMP DEC 22, 2015 10:35 AM SENSOR OUT ALARM DEC 22, 2015 10:15 AM FUEL ALARM DEC 9, 2014 11:00 AM FUEL ALARM 5 RUL SIPHON ANN DEC 22, 2015 10:35 AM SENSOR OUT ALARM DEC 22, 2015 10:22 AM FUEL ALARM DEC 9, 2014 11:04 AM FUEL ALARM 6 RUL MAIN ANN DEC 22, 2015 10:35 AM SENSOR OUT ALARM DEC 22, 2015 10:19 AM FUEL ALARM DEC 9, 2014 11:04 AM FUEL ALARM 8 DISP 1-2 DEC 22, 2015 10:35 AM SENSOR OUT ALARM DEC 22, 2015 10:27 AM HIGH LIQUID ALARM DEC 22, 2015 10:24 AM LIQUID WARNING 9 DISP 3-4 DEC 22, 2015 10:35 AM SENSOR OUT ALARM DEC 22, 2015 10:29 AM LIQUID WARNING DEC 9, 2014 11:11 AM LIQUID WARNING 10 RUL MAIN STP SUMP DEC 22, 2015 10:35 AM SENSOR OUT ALARM DEC 22, 2015 10:20 AM FUEL ALARM DEC 9, 2014 11:08 AM FUEL ALARM 11 REG PIPING SVMP DEC 22, 2015 10:35 AM SENSOR OUT ALARM DEC 22, 2015 10:21 AM FUEL ALARM MAY 21, 2015 10:51 AM FUEL ALARM I34200 DEC 22, 2015 1:27 PM 235038 7-11 16329 1701 PACHECO RD BAKERSFIELD CA 93304 B0383134105001 2 WIRE CL ALARM HISTORY REPORT SENSOR LOCATION 1 PREMIUM ANNULAR DEC 22, 2015 10:36 AM SENSOR OUT ALARM DEC 22, 2015 10:16 AM FUEL ALARM JAN 15, 2015 10:33 AM FUEL ALARM I38200 DEC 22, 2015 1:27 PM 235038 7-11 16329 1701 PACHECO RD BAKERSFIELD CA 93304 B0383134105001 PRESSURE LINE LEAK ALARM HISTORY REPORT Q 1:RUL DEC 22, 2015 11:23 AM PLLD SHUTDOWN ALARM DEC 22, 2015 11:23 AM GROSS LINE FAIL DEC 22, 2015 10:35 AM PLLD SHUTDOWN ALARM DEC 22, 2015 10:29 AM PLLD SHUTDOWN ALARM DEC 22, 2015 10:27 AM PLLD SHUTDOWN ALARM DEC 22, 2015 10:24 AM PLLD SHUTDOWN ALARM DEC 22, 2015 10:22 AM PLLD SHUTDOWN ALARM DEC 22, 2015 10:21 AM PLLD SHUTDOWN ALARM DEC 22, 2015 10:20 AM PLLD SHUTDOWN ALARM DEC 22, 2015 10:20 AM PLLD SHUTDOWN ALARM Q 2:PUL DEC 22, 2015 11:18 AM PLLD SHUTDOWN ALARM DEC 22, 2015 11:18 AM GROSS LINE FAIL DEC 22, 2015 10:35 AM PLLD SHUTDOWN ALARM DEC 22, 2015 10:29 AM PLLD SHUTDOWN ALARM DEC 22, 2015 10:27 AM PLLD SHUTDOWN ALARM DEC 22, 2015 10:24 AM PLLD SHUTDOWN ALARM DEC 22, 2015 10:15 AM PLLD SHUTDOWN ALARM NOV 18, 2015 8:39 PM ANNUAL LINE FAIL DEC 12, 2014 6:05 PM PLLD SHUTDOWN ALARM DEC 11, 2014 11:45 AM PLLD SHUTDOWN ALARM I10100 DEC 22, 2015 1:27 PM 235038 7-11 16329 1701 PACHECO RD BAKERSFIELD CA 93304 B0383134105001 SYSTEM STATUS REPORT D 5:AUTODIAL FAILURE D 5:ALARM CLEAR WARNING D 5:DELIVERY REPORT WRN